www.reading.ac.uk/cfam © University of Reading 2007 November 21, 2013 ESEM and Cryo-SEM Matthew Spink

ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

www.reading.ac.uk/cfam © University of Reading 2007 November 21, 2013

ESEM and Cryo-SEM Matthew Spink

Page 2: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 2

Overview

• Recap SEM

• Water and SEM

• Environmental SEM

• Cryo-SEM

• Comparison

• Questions/Demo

Page 3: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM

SEM - Imaging the surface of samples

3

SEM is used to gain information about a sample’s topology and composition.

Page 4: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM

• High energy “primary”

electrons hit sample surface

• “Secondary” electrons are

ejected from sample atoms

• Primary electron pass

through, into or are reflected

from sample

Primary beam 0.5-30kV

Backscatter electrons

Secondary electrons

SEM Recap

Page 5: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM

SEM Recap

•Primary beam is focused to a fine point •Then scanned across sample surface •Secondary electrons are emitted from specimen as the beam passes over it •Secondary electrons are detected and a picture is built up.

Page 6: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 6

Conventional SEM

• Electron beam

• High vacuum

– ~10-4 Pa (~10-6 torr)

• Dry samples

• Conductive samples

Page 7: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 7

Water

• Many interesting samples contain water:

– Food samples

– Marine sediments

– Plant/animal tissues

– Gels/colloids

– Suspensions of particles

Page 8: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 8

Phase diagram of water

0.01°C

611.7 Pa (4.6 torr)

100°C

98066.5 Pa (735.6 torr)

Pre

ssu

re

Temperature

Ice (solid)

Water Vapour (gas)

Water (liquid)

Conventional SEM

Page 9: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 9

Air drying a hydrated sample

Page 10: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 10

Drying Damage

Page 11: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 11

Solutions to the water problem

• Drying solutions:

– Freeze Drying

– Critical Point Drying

• Non-drying solutions:

– ESEM

– Cryo-SEM

Page 12: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 12

ESEM

• Change the microscope to suit the sample

• Preserving liquid water within the SEM chamber

• Sample cooling

• Introducing water vapour

Condensation

Page 13: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 13

ESEM: Control of humidity

Humidity can be controlled by temperature

Page 14: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 14

ESEM: Control of humidity

Page 15: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 15

ESEM: control of chamber humidity

Condensation on ostrich feathers

Page 16: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 16

Pre

ssu

re

Temperature

Ice (solid)

Water Vapour (gas)

Water (liquid)

ESEM: phase diagram of water

Page 17: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 17

ESEM: components

Cooled specimen

• Differential Pumping

• Pressure limiting aperture

• Gaseous secondary electron

detector

• Sample cooling

Page 18: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM

Cascade of secondary electrons in ESEM

• Primary electron beam

impinges on the sample

causing production of

backscattered and secondary

electrons

18

Page 19: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM

Cascade of secondary electrons in ESEM

• Secondary electrons are

accelerated towards the

anode.

• Secondary electrons collide

with water vapour molecules

producing more secondary

electrons.

• This produces a cascade of

electrons which is detected.

19

Page 20: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 20

Secondary electrons from sample strike water molecules.

Positively charged water molecules are attracted to negatively charged sample.

Negative charge at sample surface is neutralized.

Adding water vapour in ESEM has the added benefit of negating the samples charge allowing non-conductive samples to be imaged.

Added benefit of water vapour in ESEM

Page 21: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 21

ESEM: no sample prep

Cocoa embryo torpedo stage Basil leaf

Page 22: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 22

ESEM: minimal sample prep

Potato, starch grains in situ Potato, starch grains washed out

Page 23: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 23

ESEM: other samples

Fat crystals Preserved nematode

Page 24: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 24

Gaseous secondary electron detector – fits on objective lens.

ESEM: FEI Quanta 600F

• Full ESEM capability

• Pressures up to 2666Pa / 20 torr

• Samples typically cooled to ~5°C

Page 25: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 25

ESEM: limitations

• Limited Resolution ~10x

worse than conventional SEM

• Slightly limited field of view

• Lack of contrast

Hemp leaf surface

Page 26: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 26

Cryo-SEM

• Change the sample to suit the

microscope

• Perform SEM on frozen

samples

Arabidopsis seed

Page 27: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 27

Cryo-SEM: how does it work?

1. Sample is frozen

2. Frozen sample is handled

under vacuum

3. Fractured/sublimation/coating

4. Frozen sample transferred to

SEM cryo stage

5. Normal high vacuum imaging

Cryo-stage

Page 28: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 28

Pre

ssu

re

Temperature

Ice (solid)

Water Vapour (gas)

Water (liquid)

Cryo-SEM: phase diagram of water

Page 29: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 29

Cryo-SEM: fracturing liquid samples

Xanthan Gum in water Natural Greek yogurt

Page 30: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 30

Cryo-SEM: fracturing temperature

Cotoneaster leaf fractured at -140°C Grass leaf fractured at -190°C

Page 31: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 31

Cryo-SEM: sublimation

Ice cream (-90°C for 15mins @ ~10-3 Pa) Ice cream (-90°C for 5mins@ ~10-3 Pa)

Page 32: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 32

Cryo-SEM: FEI Quanta 600F

• SEM mounted preparation

chamber

• Quorum: PolarPrep 2000

Page 33: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 33

Cryo-SEM: procedure

4

3

2 1

Page 34: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 34

ESEM and cryo-SEM: common samples

Drosera adelae stigma, ESEM Drosera adelae stigma, cryo-SEM

Page 35: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 35

Cryo-SEM: unique samples

60% oil in water emulsion Cappuccino foam

Page 36: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 36

Cryo-SEM: magnification range

Natural Greek yoghurt Drosera adelae flower

Page 37: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 37

Cryo-SEM & ESEM: Summary

• Both: hydrated samples

• ESEM: less sample preparation

• ESEM: faster

• Cryo-SEM: higher magnifications

• Cryo-SEM: liquid samples

Page 38: ESEM and Cryo-SEM - University of Reading · 12 ESEM and Cryo-SEM ESEM • Change the microscope to suit the sample • Preserving liquid water within the SEM chamber • Sample cooling

ESEM and Cryo-SEM 38

Demo/Questions?