AT-SINC Authorized Distributor for DYNAMIC AIR SHELTERS AT-SINC 1670 S. Amphlett Blvd., Ste 214 San Mateo, CA 94402 P: 650-832-1309 E: [email protected] Web: http://airshelters.at-sinc.com EXPLOGROUP PERU Calle Adam Smith, Mz. H, Lte.4, Int. C Lima 39 - Peru Phone: (511) 266-3485; (51)99919-6050 E: [email protected] Web: http://explogroup.com

Explo groupperu at-sinc presentation

Embed Size (px)

Citation preview

AT-SINC

Authorized Distributor for

DYNAMIC AIR SHELTERS

AT-SINC 1670 S. Amphlett Blvd., Ste 214

San Mateo, CA 94402

P: 650-832-1309

E: [email protected]

Web: http://airshelters.at-sinc.com

EXPLOGROUP PERU Calle Adam Smith, Mz. H, Lte.4, Int. C

Lima 39 - Peru

Phone: (511) 266-3485; (51)99919-6050

E: [email protected]

Web: http://explogroup.com

ISO 9001:2008

History

AT-SINC • Founded in 2000 in San Francisco Bay area from predecessor company

• Engaged in various markets worldwide:

• Worldwide Dynamic Air Shelter Distributor

• CRM & ERP software consulting and implementation for Oracle and

Microsoft

• Asset Management consulting and software

Dynamic Air Shelters, Inc. • DAS. began in the outdoor promotional business over 20 years ago.

• Leading supplier of hot air balloon advertising.

• 1994 began building air beam structures.

• 2005 an explosion at BP Texas City prompted the testing of air beam structures.

• 2007 the first Blast Resistant Structure was fielded at Sunoco Philadelphia

• 2011 blast test to the thresholds of destruction demonstrated that the shelter

would deflect and reduce threats to survivability even when reaching the points

of its own critical failings.

The Next Generation in Portable

Shelters Is Here Today

• Characteristics – Blast Proof

– Hurricane Proof (up to Cat. 3 – 130 mph)

– Earthquake Resistant

– Fire Resistant

– Easy Install – No Lifting Equipment Required

– Long Asset Life

– Easily Re-deployable

– Thermally Efficient

– Supports Deployment in Extreme Temperatures

INSTALLATIONS – SAFE AND EASY

25 x 55 meter lunch room

BRS Components • Outer Fly

• Can be customized with client colors and logos

• Typically two logos per order. Extra logos need to be priced

• Fabric composition - Vinyl Coated nylon, 16oz

• Heavier standard fabric is available for extreme environments

• Kevlar also available

• Base fabric – Nylon 4.6oz

• Coating type – Polyvinyl Chloride

• Max Strip Break Strength – 375lbs

• Max Tear Strength – 150lbs

• Cold crack resistant to -65F

• Heat resistant to 170F

• Flame resistance - CCC-T-191Method 5902, NFPA 701

• Finish - UV inhibitors

• Mildew resistance - impermeable

• Note: Inner fly is essentially the same but a lighter

weight fabric

BRS Components Cont`d • Air Beams (legs)

• Fabric composition - Vinyl Coated poly, 31.5oz

• Base fabric – Polyester, 10.6 oz./sq yd.

• Coating type – Polyvinyl Chloride

• Max Strip Break Strength – 550bs

• Max Tear Strength – 270lbs

• Cold crack resistant to -55F

• Heat resistant to 158F

• Flame resistance - CFM Title 19 NFPA 701 / CSFM

• Finish – Vinyl Coating

• Mildew resistance – impermeable

• Hug straps provide connection points for

anchoring

• Each point can support up to 200 pounds

• Provides connection points for

• Lighting

• Cable clothes racks

• Media components (TV, speakers)

Components Cont`d • Inflation System (pre-inflation)

• Modified electric leaf blower

• High volume

• Low pressure

• Used to inflate legs to approximately to .5 PSI and 90% volume

• Requires 12 amps

Components Cont`d

• Inflation System (normal operation)

• Blowers

• 3.8 amp

• 3/4 horse power

• 1.5 PSI

• Can be made intrinsically safe

• Air on Demand System

• Critical to keep columns at 1.5 PSI

• Typically runs 20 to 30 minutes per day

• Each column has a sensor

• Every other column and end section on a different loop

Components Cont`d • Inner curtain

• Improves Insulative Properties

• Reflective properties provides bright interior

• Provides finished look and protects columns

• Air Plenum • Even distribution of heating and cooling

• Lighting • Sealed Fluorescent

• Can be Class 1 Division 2

Components Cont`d • Doors (steel)

• Single (36”) or double (72”) wide doors

• Single or double door vestibule

• Multiple anchoring options

• Tested to 8 PSI

• Doors (inflatable)

• 72” inflatable

• Used in very high treat area

• Life expectancy shorter than steel

• Used when doors are facing threat

BRS Components Cont`d • Flooring

• Stage Flooring • 4 ft x 4 ft panel

• Metal framed

• Wood decked

• Adjustable up to 36 inches in height

• Diamond eye pads for attaching legs

• Vapor Barrier • Used underneath raised flooring

• Used for:

• Long installations

• On compacted earth

• On concrete or pavement

7 x 22 meter lunch room

Mobile field hospital

Mobile field hospital interior

Cool down stations

Weather Protection

Gold mining camp - One hurricane & two tropical storms in three

weeks

30 x 90 meter construction cover

Open a door, open a wall, with no affect on integrity

Large open and clear spans allowing for heavy machinery

Excavation

Cover

Installed

in

Three

hours

Equipment Maintenance Shelters

Warehouse

Large freight doors integrated with the inflatable

Military Vehicle Maintenance Shelter

16 x 70 meter Emergency Response Shelter in Arctic

16 x 70 meter Emergency Response Shelter in Arctic

Canada's Prime Minister Addressing Crew

Features and Benefits Summary

• Structures do not require extensive ground prep

• Able to achieve large clear spans (over 100 feet wide)

• Easily transported

• Portable and easy to install, move and demobilize

• Thermally Efficient

• Low total cost of ownership (energy and maintenance)

• Life spans up to 20 years

• Fire Resistant

• Earthquake proof

• Hurricane proof (up to Cat 3)

• Occupant comfort – high morale

• Fail safe

• Safe fail

• Wide ranges of uses

• Custom colors, sizes, configurations

AT-SINC

Authorized Distributor for

DYNAMIC AIR SHELTERS

AT-SINC 1670 S. Amphlett Blvd., Ste 214

San Mateo, CA 94402

P: 650-832-1309

E: [email protected]

Web: http://airshelters.at-sinc.com

EXPLOGROUP PERU Calle Adam Smith, Mz. H, Lte.4, Int. C

Lima 39 - Peru

Phone: (511) 266-3485; (51)99919-6050

E: [email protected]

Web: http://explogroup.com