InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-58801
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
HART® OverviewCable and CordsetsJunctionsDevice GlandsTees and AdaptersReceptaclesField Wireables and Accessories
FOUNDATION™ Fieldbus OverviewCable and CordsetsJunctions (Bricks)Device GlandsTerminating ResistorsTees and AdaptersSurge Suppressor, Power Conditioner and Lokfast™ GuardReceptaclesField Wireables and Accessories
Process Fieldbuses
busstop® OverviewConnector SpecificationsPre-molded Fieldbus CablesPart Number Keys
1
2
PROFIBUS®-PA OverviewCable and CordsetsJunctions (Bricks)Device GlandsTerminating ResistorsTees and AdaptersSurge Suppressor and Lokfast™ GuardReceptaclesField Wireables and Accessories
4
Installations
Index of Components
6
5
2789
131622283031353840
434652585961656870
72748286879194
98
116
3
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-58802
InterlinkBT™ - A Banner-TURCK Bus Products CompanyInterlinkBT is a joint venture between two renowned sensor companies, TURCK, Inc. and Banner Engineering, to focusspecifically on bus products. The experience and advanced bus technologies of these companies are now combined,resulting in the industry’s broadest, most complete line of stations, junctions, cordsets and components for device-levelnetworks. InterlinkBT is the industry’s bus I/O specialist and leading supplier of top-quality bus products.Most importantly, InterlinkBT is your best solution to connect input/output devices to open buses.
A Worldwide Fieldbus Solution
Cable
This catalog covers high quality on-the-machine and at-the-process FOUNDATION™ Fieldbus H1, PROFIBUS®-PA andHART® interconnect products. The product offering emphasizes materials for diverse applications where aggressiveenvironments are often the norm.
InterlinkBT has the products for interconnecting all your devices on a network segment. By simply plugging componentstogether these products allow for quick installations of new plant layouts and easy alterations to existing installations.InterlinkBT’s junction blocks are rugged and can be mounted in aggressive environments. Spur or drop count can varyfrom 4 to 8 with the choice of minifast® or eurofast® connector sizes.
InterlinkBT cable exceeds ISA SP50.02 specifications for impedance and attenuation. Pre-molded cordsets are availablewith either minifast® or eurofast® connector sizes. The easy-to-use terminating resistor simply screws into the end ofthe Home Run cable. You can reliably use InterlinkBT fieldbus products in the harshest of environments.
InterlinkBT’S Process Fieldbuses Catalog
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-58803
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Not all the I/O in a fieldbus system can be connectorized, but when it can it is extremely effective. A few minutes oflayout and bill-of-material planning can replace hours of costly wire installation. In addition, product replacement isgreatly facilitated by using industrial grade quick disconnect plug-and-play receptacles.
InterlinkBT uses two industrial standardized connectors. The generic names for them are “Mini” and “Micro or Euro”.In one variation or another these two standardized connectors are produced by the thousands. Rough estimates put the“Mini” style at over 10,000 per day and the “Euro” at over 25,000 per day. They are used in every industry that requiresrugged economic plug-and-play connectorization. Both were standardized by DIN (German Industrial Standards) in theirearly design. Today they are recognized standards throughout the world.The sheer volume means that the build processes for these two standards are understood, tooled, automated, and eco-nomical. The volume and breadth of applications means that broad selections of off-the-shelf products are available.
There are three materials for coupling nuts; stainless steel, nylon and nickel-plated brass. The mating pin and sleeves aregold-plated brass. The body is made of polyurethane and is injection molded to the cable jacket to provide strain reliefand to seal the connections from the atmosphere.
The Mini’s pin and sleeve are rated at 9 amps and the Micro is rated at 4 amps. The designated ground pin of the Minifamily is longer than the other pins, resulting in a make-first/break-last ground. This feature is not explicitly required forIS or NI applications, but is a sound engineering choice. All the pins of the Euro make and break at the same time duringinsertion and removal.
The junction boxes shown in this catalog are passive hubs. Although no conditioning or monitoring takes place, somejunctions have short circuit protection. This protects the power on the trunk and allows use in Class 1, Div 2 locations.The boxes are made from two different materials; copper-free die-cast aluminum with a powder coated enamel finish orpolyurethane overmold. Both housings are available with either 316 stainless steel or nickel plated brass connectors.
The junction boxes are rated NEMA 1, 3, 4, 4X, 12, 13 and IEC IP 67. These ratings are conditional, requiring thecordset or cap to be installed. Although the die cast housing is rated 4X (salt-water spray test) we highly recommend thepolyurethane or fiberglass housing for aggressive environments.
Connectors
Junction Boxes
1
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-58804
Active hub - a multiple port repeater or amplifier that lengthens the branching ability of a bus.Barrier Box - limits current/voltage to an area.Brick - fully connectorized passive junction.Bridge - there are two types; one is a double-sided node that connects two segments together that are the same protocol butdifferent transmission speeds, the other is a smart repeater that only repeats the data between two bus segments when thesource and destination address are in different segments. The bridge must be programmed to know what the addresses areand their respective segments.Bus Junction - generic name for a passive hub.Busline - any group of wires that carries data from node-to-node.Dropline - a reduced branch (spur) from a trunkline.Gateway - a special node on two different buses that serves as a signal and data translator between the buses.LAS (Link Active Scheduler) - controls comunication on the bus. Creates a token circulation list (Live List) that definesaccess on the bus. Devices may only communicate when given access by the LAS unit. Multiple devices may have LAScapabilities but only one can communicate at a time.Node - an addressable device on the bus.Power Conditioner - device used to condition the power to be for a bus segment. Allows power and data to exist on thesame wires.Repeater - a product that strengthens a signal, while adding up to a half-bit wait state and producing a fresh signal withoutdistortions. It also links two portions of the same bus together. A repeater is used when a signal is weak or distorted.Router - a higher level bridge for connection of wide area networks.Simple Device - anything that does not have LAS capabilities.System Tee - a field wireable tee.Tee - a product that creates a branch or drop from a bus.Terminating resistor - a resistor that is put at the beginning and end of the main busline to stabilize and minimize reflections.Trunk line - the main busline.
Occupants on the Bus
To Control Highway
Fieldbus I/O Host
Main Trunk CableMain Trunk Cable
Spurs
Pressure Transmitter
JTBS-49SC-M633JTBS-49SC-M633
JTBS-49SC-M633
Terminator
BRPS-49-M213
24V 24V
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-58805
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Topology is a term that applies to buses. It describes how the data lines connect the nodes together. The first bus goesback to the original telegraph - two data lines hanging on wooden poles going from telegraph station to telegraph station.
Bus - the simple straight-line topology is called a bus. Another term used is “Daisy Chain”, where the trunk simply runsfrom device to device.Branch - a common bus can have branches, and sometimes the branches can have branches. Another term used todescribe the branches is “drops” or “spurs”, as in FOUNDATION™ Fieldbus. Depending on the bus the branches may berestricted to just a few centimeters or a free-form topology with restrictions only on the cumulative distance of all datalines.Star - the bus lines radiate from a single point. A junction (either passive or active) looks like a star. FOUNDATION™Fieldbus also refers to this as a “chicken foot” topology with many branches connected in a relatively small area.
Bus Topology1
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-58806
There are several different bus types utilizing the following technologies:
Client / Server - upload/download information, setpoint changes, alarm management, remote diagnostics and one to onecommunications.
Media Access - this is the “right-of-way” for talking on the bus. There are three main types:Master Control - one super node controls all transmission, sequence and time. Remaining nodes do not talk unless told to by the master.Token Passing - this is a message shift method that is incremented in a manner that allows each node a chance to talk
during each cycle.CSMA - an access method allowing each node to speak, provided that it has something to say and no other node is talking
on the line.
Message Collision Avoidance - when two people talk simultaneously there is a verbal collision. A few humans can talk andlisten to someone else at the same time but nodes cannot. Both token passing and master control do not have that problem. Afield node can only access the bus when it is its turn to talk or when it has been told to talk. CSMA-type buses do have thisproblem. The problem goes away when they are operated as a master-to-slave. When operating in the native CSMA accessmethod two nodes could start talking simultaneously. Two major ways have been developed to handle a potential collision:
CD - collision detection - all senders must also be receivers. If two nodes start talking at the same time they will hear a collision. Both stop talking, wait a random length of time, then look for a clear line to start talking again.
BA - bitwise arbitration - all senders must also be receivers. The busline must be of a specific length or less so that all nodes hear the bit at the same time (actually the first node and the last node can be approximately 1/6 bit apart).
Messaging - there are three major types in the run mode, but many more during start-up and initialization.Solicited - a response to another node or a response when it is the node’s predetermined time to speak (token passing).Unsolicited - a response to a change-of-state at the node.Explicit - a command order. It may command an output be turned “On” or “Off”. It may command any node to
report its diagnostic status or identity itself in full detail.
One last distinction must be made for the output nodes. How do they get the information so they know what to do?Although there is an overlap with the terms used for messaging, there are important differences:
Explicit Message - this is a command from another node.
Limited Peer-to-Peer - exclusive one-to-one relationship between the input node and the output node. This could also becalled exclusive peer-to-peer.
Unlimited Peer-to-Peer - similar to limited peer-to-peer, but the output node may get information from several input nodes.
Publisher / Subscriber - scheduled distribution of data to nodes on the subscriber list.
Bus Types
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-58807
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
eurofast® Connector-M12 x 1 thread-100% electrically tested-Meets: IEC 61076-Current Rating: 4A-Voltage Rating: 300V-Protection: NEMA 1,3,4,6P and IEC IP67-NEMA 4X with stainless steel coupling nuts
Connector Specifications
-Temperature: -30ºC to +85ºC-Vibration: 10 to 500 Hz and 0/35mm or 5g-Pull Strength: 50 lbs
minifast® Connector- 7/8” - 16UNF thread-100% electrically tested-Meets: SAE H1738-2-Current Rating: 9A-Voltage Rating: 300V-Protection: NEMA 1,3,4,6P IEC IP67-NEMA 4X with stainless steel coupling nuts-Temperature: -30ºC to +85ºC-Oscillation: 65mm (2.5in.) to 125mm (5in.)-Pull Strength: 100 lbs - 5 to 12.5 cycles/sec. for 2 million cycles
multifast® Connector- M23 x 1 thread-100% electrically tested-Current Rating: 4A-Voltage Rating: 300V-Protection: NEMA 1,3,4,6P IEC IP67-Temperature: -30ºC to +85ºC
1
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-58808
Pre-molded fieldbus cables ensure simple and secure wiring of the connected fieldbus components. Time-consuming wiring of individualcomponents and bus communication problems due to wiring errors or incomplete shielding are eliminated.Molded polyurethane insulation provides IP67 protection.Standard lengths of pre-molded cordsets and bulk cable are listed below. Consult the factory for other lengths.
Pre-molded Fieldbus Cables
Cordsets Bulk Cable
meters feetmeters feet
0.3
0.5
1.0
1.5
2.0
2.5
3.0
4.0
5.0
6.0
8.0
10
15
20
25
30
40
50
1.0
1.6
3.3
4.9
6.6
8.2
9.8
13
16
20
26
33
49
66
82
98
131
164
30
75
150
225
300
98
246
492
738
984
- - -- - -
Other lengths available upon request.
Unit Conversions:1 meter = 3.2808 feet1 meter = 39.79 inches
Tolerances:0-1 meter: +35 / - 0 mm> 1 m +85/-0 mm or +4% of length which ever is greater
Standard Cable Lengths
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-58809
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
R S C V 4 9 M
F S F V 4 9 M
eurofast® Part Number Keys
Cordsets
Receptacles
Designator for eurofast®
V(Blank)
= Stainless Steel= Nickel-Plated Brass
48* (see page 47)49* (see page 17)H4* (see page 75)
Cable Type (x)
Length in Meters (*)
Designator for eurofast®
SK
= Male Connector= Female Connector
Designator for Receptacles
Coupling Nut Material
Coupling Nut Material
V(Blank)
= Stainless Steel= Nickel-Plated Brass
Gender
Gender
Length in Meters (*)
x *
Standard 0.3, 0.5, 1, 1.5, 2 ....(see page 8)Consult factory for other lengths
x *
Standard 0.3, 0.5, 1, 1.5, 2 ....(see page 8)Consult factory for other lengths
Cable Type (x)
SK
= Male Connector= Female Connector
RW
= Straight= Right Angle
48* (see page 47)49* (see page 17)H4* (see page 75)
1
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588010
Length in Meters (*)
W K M 4 9 M
R K F V 4 9 M
minifast® Part Number Keys
Cordsets
Receptacles
Gender
MV(Blank)
= Nickel-Plated Brass= Stainless Steel= PA 6.6 (Nylon)
Coupling Nut Material
RW
= Straight= Right Angle
Gender
Designator for Receptacles
Coupling Nut Material
VM(Blank)
= Stainless Steel= Nickel-Plated Brass= PA 6.6 (Nylon)
Cable Type (x)
SK
= Male Connector= Female Connector
RW
= Straight= Right Angle
SK
= Male Connector= Female Connector
x *
x *
Cable Type (x)
Length in Meters (*)
48* (see page 47)49* (see page 17)H4* (see page 75)
48* (see page 47)49* (see page 17)H4* (see page 75)
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588011
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
J T B S 4 9 SC M 6 3 3
= Junction TeeJTJB = Junction Box
Bus System
4849
= PROFIBUS®-PA= FOUNDATION™ Fieldbus
ProtectionSC(Blank)
= Short Circuit= None
= minifast®= eurofast®
ME
Number of Ports
Connector Type
Connector Material34
= Stainless Steel= Nickel-Plated Brass
Housing1234
= Aluminum (JBBS only)= Fiberglass (JBBS only)= Polyurethane (JTBS only)= Hytrel (JTBS only)
Junction Tee Part Number Key
1
40607080
- 4 ports- 6 ports- 7 ports- 8 ports
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588012
40607080
- 4 ports- 6 ports- 7 ports- 8 ports
HHM
Number of Ports HART® Topology
Home Run ConnectorCS12CS19RSRSV
- multifast® 12-pin - multifast® 19-pin - minifast® 5-pin - minifast® 5-pin with stainless steel coupling nut
HART® Junction Box Part Number Key
V B M 4 0 H C S 1 2
Housing
VBM
4MB12or
8MB12
JTBS
-
-
-
Metal Housingeurofast® Connectors
Nylon Housingeurofast® Connectors
Polyurethane Housingminifast® Connectors
- HART® Point-to-Point- HART® Multidrop
For HART® Systems Only
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588013
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
FOUNDATION™ Fieldbus Cables and Accessories
2
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588014
FOUNDATION™ Fieldbus OverviewFOUNDATION™ Fieldbus is a communication protocol and defined physical method to interconnect smart devices such astemperature transmitters, pressure transmitters and valve actuators. The physical layer conforms to ISA SP50.02 and IEC1158-2 standards for fieldbuses. In comparison to 4-20 mA loops that only allow for one device connection per twistedpair, fieldbus technology enables many smart devices to share one communication medium. The digital communicationsignal is superimposed onto a DC carrier. This greatly reduces the amount of terminations needed to connect all the fielddevices to a host system. It also allows greater flexibility for future additions of I/O points.
A FOUNDATION™ Fieldbus device is addressable and has capablities to store and transmit data. The devices can storevalues, track changes and use pre-set alarms to trigger. Based on pre-defined tag names, host systems can read transmit-ter values such as temperature and pressure or set values of a valve actuator.
The digital signal encoding is done using Manchester BiPhase-L and error checking is done with the CRC method.FOUNDATION™ Fieldbus has two types of devices; a Basic Device (BD) and a Link Active Scheduler (LAS). A BasicDevice is designed to read inputs, track values and set outputs if programmed to do so. A LAS device performs the samefeatures as a BD, however it goes one step further by handling network communication timing between all the activedevices on the network. The LAS essentially creates a time table so that all devices can get a chance to transmit/receivedata on the bandwidth. A fieldbus segment can have many Basic Devices but must have at least one Link Active Sched-uler. At least two LAS devices are recommended on the network to provide redundancy. If there is more than one LASon the network, the one that powers-up first gets the LAS designation and the other LAS unit switches to BD mode ofoperation.
In essence, all devices on a fieldbus segment are connected in parallel. All transmitters connected to the fieldbus segmentlisten to all communication signals, however the protocol determines the rules as to which devices respond to the messages.For the purpose of this guide only the physical layout will be discussed in detail. The general layout is either a Star (chickenfoot) or Daisy Chain.
93.3FM
1 2 3 4 5
Figure 1 Parallel Wiring Diagram
General Layout Topologies
Communcation SignalThe FOUNDATION™ Fieldbus H1 communication signal is a square waveform superimposed on a DC carrier. Thefrequency of the signal is 31.25Khz. Although they do not have to, most devices derive their supply power from thefieldbus communications cable. The fieldbus specification states that devices must not be polarity sensitive. It is goodelectrical practice though to have all devices wired with the same polarities. The voltage range allowed for properoperation is 9-32 VDC. A typical fieldbus device will consume 20 mA of current.
Figure 1 - Parallel Wiring Diagram
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588815
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Star Topology MethodA Star topology has a central connection point for all terminations. This layout works well when there are many devices ina localized area. For instance, the control room may be located about 300 meters away from a cracker tower. This towermay have five or six temperature transmitters. All of these devices need to be connected to the fieldbus segment. The bestdesign would be to connect them all to a junction brick and then run a Home Run cable from the junction brick back to thecontrol room. See Figure 2 for a pictorial example.
The Home Run cable is considered the main trunk line for communication. Each device that is connected to the junctionbrick is called a spur. In other industrial networks spurs are called drops off the trunk line.
Figure 2 - Star Topology Example
Daisy Chain ConfigurationIn a Daisy Chain configuration each device would require a tee so that the Home Run cable would be able to go to eachdevice. From a design standpoint, the Daisy Chain method is easiest to do when the exact cable tracks are known. Pre-made cordsets can then be purchased, making the network easy to assemble. See Figure 3 for an example drawing. Afieldbus transmitter is connected to each of the tanks in the field. The Home Run cable essentially is routed to eachdevice in series.
In many fieldbus installations it makes sense to mix both Star and Daisy Chain topology layouts. The key to the wiringdesign is to make layouts valid per the fieldbus specifications. One of the benefits to fieldbus is reduced wiring ofdevices, leading to faster start-up times.
Figure 3 - Daisy Chain LayoutTransmitters
2
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588016
Fieldbus Cable SpecificationsThe specifications for fieldbus H1 physical media are defined by IEC 1158-2 and the ISA-S50.02 Part 2 Physical LayerStandards. The same standard is also listed in the FOUNDATION™ Fieldbus specifications under 31.25 Kbps Physical LayerProfile FF-816-1.4. There are essentially four types of cable designations for Fieldbus. Type A cable is the most preferredfor new installations because it allows for the most versatile lengths. The other types of cable are for installations wherecable already exists from 4-20 mA systems. See Table 1.
Type Cable Description Conductor Size Maximum Length
Type A
Type B
Type C
Type D
Shielded, Twisted Pair
Shielded, Multi Twisted Pair
Shielded, Untwisted Pair
Unshielded, Multi Twisted Pair
# 18 Awg
# 22 Awg
# 26 Awg
# 16 Awg
1900 m (6232 ft)
1200 m (3936 ft)
400 m (1312 ft)
200 m (656 ft)
InterlinkBT offers cables with both two conductors and three conductors, with the third conductor available for a central-ized ground of devices if needed. InterlinkBT cables meet or exceed the specifications of ANSI/ISA-SP50.02-1992, thefieldbus standard for use in industrial control systems.
Table 1 - Fieldbus Cable Specifications
Cable SpecificationsType A Cable- Temperature range: -50 to 105°C(-58 to +221F)- Governed by: ISA SP50.02 specification- Sunlight resistant- PLTC and ITC rated (CSA FT4)- Impedence[Z at f (31.25 kHz)] = 100Ω ± 20%- Maximum attenuation at 1.25 f (39 kHZ) = 3.0 dB/km- Maximum capacitive unbalance to shield = 2 nF/km- Maximum DC resistance (per conductor) = 24 Ω/km- Maximum propagation delay change 0. 25 f to 1.25 f = 1.7 µs/km- Conductor cross-sectional area (wire size) = nominal 0.8 mm (#18 AWG) * type 496 0.2 mm (#16 AWG)- Minimum shield coverage shall be 90%
0 rr
r r 22
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588817
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Our cable meets the requirements of ISA/SP50and FOUNDATION™ Fieldbus requirements forType A cable. All cables are rated -40ºC to105ºC and are sunlight resistant. Cables areavailable in 3-wire versions with a deviceground or 2-wire versions.
Trunk
1900 m
FOUNDATION™ Fieldbus - Cable Specifications
OverallFoil Shield
Device GroundGreen/Yellow
DataBlue
Brown
Device GroundGreen/Yellow
DataBlue
Brown
B
B
A
A
B
Type ApprovalData Pair
AWGColor Code
DCR (/1000 ft)Insulation
Device Ground
AWG Color Code
Outer JacketMaterial ColorNominal O.D.
ShieldsType
Drain Wire
NetworkStandard
490
490B
492A
492BA
493
493B
ITC PLTC300V [CMG]
ITC PLTC300V [CMG]
ITC PLTC300V or CM
[CMG HLBCD]
ITC PLTC300V [CMG]
ITC PLTC300V [CMG]
2/18 AWGBlue/Brn
2/18 AWGBlue/Brn
2/18 AWGBlue/Brn
2/18 AWGBlue/Brn
2/18 AWGBlue/Brn
2/18 AWGBlue/Brn
6.5 OhmsPE
6.5 OhmsPE
6.5 OhmsPE
6.5 OhmsPE
6.5 OhmsPE
6.5 OhmsPE
18 AWGGreen/Yellow
18 AWGGreen/Yellow
18 AWGGreen/Yellow
18 AWGGreen/Yellow
None
None
PVC Yellow7.9mm (.310 in)
PVC Blue7.9mm (.310 in)
Armor/PVC Yellow12.7mm (0.5 in)
PVC Yellow7.9mm (.310 in)
PVC Blue7.9mm (.310 in)
Armor/PVC Blue12.7mm (0.5 in)
Foil20 AWG
Foil18 AWG
Foil20 AWG
Foil/Braid20 AWG
Foil/Braid20 AWG
Foil18 AWG
ISA / SP50
ISA / SP50
ISA / SP50
ISA / SP50
ISA / SP50
ISA / SP50
496 2/16 AWGBlue/Brn
4.3 OhmsPE
None PVC Yellow8.5mm (.335 in.)
Foil20 AWG ISA / SP50
A
A
A
Ref.UL [CSA]
A
ITC PLTC300V or CM
[CMG HLBCD]
ITC PLTC300V [CMG]
Cable
25 - 3219 - 2415 - 1813 - 142 - 12
0 m (0 ft)30 m (98 ft)60 m (197 ft)90 m (295 ft)120 m (394 ft)
# of Devices Max Spur Length
2
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588018
min
ifast
® ♣♣♣♣ ♣
euro
fast®
**
eurofast®**
Sock
et (F
emal
e)So
cket
(Fem
ale)
Pin
(Mal
e)Pi
n (M
ale)
RSV
WSV
RKV
WKV
RSCV
WSCV
RKCV
WKCV
RSV
RKV
WKV RSCVWSV
Pin (Male) Socket (Female) Pin (Male)
minifast® ♣♣♣♣♣
RSV 49 -*M
RSV RSV 49 -*M
WSV 49 -*M RKV 49 -*M WKV 49 -*M RSCV 49 -*M
RSV WSV 49 -*M RSV RKV 49 -*M RSV WKV 49 -*M RSV RSCV 49 -*M
FOUNDATION™ Fieldbus - Cable and Cordsets
WSV WSV 49 -*M WSV RKV 49 -*M WSV WKV 49 -*M WSV RSCV 49 -*M
RKV RKV 49 -*M RKV WKV 49 -*M RKV RSCV 49 -*M
WKV WKV 49 -*M WKV RSCV 49 -*M
RSCV RSCV 49 -*M
×
×
×
×
×
×
×
×
× ×
×
×× ×
×
×
×
×
×
×
× Indicates cable typeIndicates length in metersStandard cable onlyArmorfast® cable onlyFor nickel-plated brass coupling nut: RSV...to RSM...
RSCV...to RSC...
***♣♣♣♣♣
Bulk cable, see page 8 for standard lengths.
Example
WSV RSCV 490-1M
1 METER
Bare
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588819
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
minifast® bulkheadeurofast® ** eurofast® bulkhead
Pin (Male)Pin (Male)Pin (Male) Socket (Female) Socket (Female) Socket (Female)
RKCVWSCV RSFPV RKFPV FSFDV FKFDV
WSCV 49 -*M RKCV 49 -*M WKCV 49 -*M RSFPV 49 -*M RKFPV 49 -*M FSFDV 49 -*M FKFDV 49 -*M
RSV WSCV 49 -*M RSV RKCV 49 -*M RSV WKCV 49 -*M RSV RSFPV 49 -*M RSV RKFPV 49 -*M RSV FSFDV 49 -*M RSV FKFDV 49 -*M
WSV WSCV 49 -*M WSV RKCV 49 -*M WSV WKCV 49 -*M WSV RSFPV 49 -*M WSV RKFPV 49 -*M WSV FSFDV 49 -*M WSV FKFDV 49 -*M
RKV WSCV 49 -*M RKV RKCV 49 -*M RKV WKCV 49 -*M RKV RSFPV 49 -*M RKV RKFPV 49 -*M RKV FSFDV 49 -*M RKV FKFDV 49 -*M
WKV WSCV 49 -*M WKV RKCV 49 -*M WKV WKCV 49 -*M WKV RSFPV 49 -*M WKV RKFPV 49 -*M WKV FSFDV 49 -*M WKV FKFDV 49 -*M
RSCV WSCV 49 -*M RSCV RKCV 49 -*M RSCV WKCV 49 -*M RSCV RSFPV 49 -*M RSCV RKFPV 49 -*M RSCV FSFDV 49 -*M RSCV FKFDV 49 -*M
WSCV WSCV 49 -*M WSCV RKCV 49 -*M WSCV WKCV 49 -*M WSCV RSFPV 49 -*M WSCV RKFPV 49 -*M WSCV FSFDV 49 -*M WSCV FKFDV 49 -*M
RKCV RKCV 49 -*M RKCV WKCV 49 -*M RKCV RSFPV 49 -*M RKCV RKFPV 49 -*M RKCV FSFDV 49 -*M RKCV FKFDV 49 -*M
WKCV WKCV 49 -*M WKCV RSFPV 49 -*M WKCV RKFPV 49 -*M WKCV FSFDV 49 -*M WKCV FKFDV 49 -*M
×
×
×
×
×
×
× ×
×
×
×
×
× × × ×
× × × ×
× × ×
× × ×
×
×
× × × ×
× × × ×
× × × ×
× × ×
× ×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
FOUNDATION™ Fieldbus - Cable and Cordsets
WKCV
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588020
minifast® Cordset and Receptacle Connector Dimensions and Pinouts
RSV-* RKV-*
WSV-* WKV-*
MALE FEMALE
RSFPV-* RKFPV-* Mounting Installation
Bracket dimensions are in [millimeters].Pinouts according to CENELEC EN 50 044 numbering convention.
1. Blue (-Voltage)2. Brown (+ Voltage)3. Bare (Shield Drain Wire)4. Green/Yellow (Ground)
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588821
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
RSCV-* RKCV-*
WSCV-* WKCV-*
eurofast® Cordset and Receptacle Connector Dimensions and Pinouts
FEMALEMALE
Mounting InstallationFSFDV-* FKFDV-*
1. Blue (-Voltage)2. Brown (+ Voltage)3. Bare (Shield Drain Wire)4. Green/Yellow (Ground)
2
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588022
Electrical♦ Short Circuit Protection: 55mA (Isc)♦ Voltage Open Circuit: 35VDC♦ Current Consumption: 5mA
Diagnostic♦ LED Indication:
Green LED - Bus PowerRed LED - Short Circuit Indication
Short Circuit minifast® Junction Tee
Specifications
Description
Dimensions
The FOUNDATION™ Fieldbus junction tee is available with short circuit protection andis FM Approved for Cl 1, Div 2 hazardous locations. Mechanically rugged, the newovermolded design provides unparalled corrosive resistance.
JTBS-49SC-M633
Short Circuit Protection (only available with SC models)
Cl 1, DIV 2; Groups A-D See InterlinkBT drawing N1-2.400 T6, Ta = 70°C
* minifast® models only, eurofast® approvals pending
SC models only
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588823
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
JTBS-49-M433
JTBS-49-M434
JTBS-49-M633
JTBS-49-M634
JTBS-49SC-M433
JTBS-49SC-M434
JTBS-49SC-M633
JTBS-49SC-M634
Num
ber o
f Por
ts
Con
nect
or S
ize
Ove
rmol
d M
ater
ial
Con
nect
or M
ater
ial
Shor
t Circ
uit P
rote
cted
4
4
4
4
6
6
6
6
stainless steel
nickel-plated brass
stainless steel
stainless steel
stainless steel
nickel-plated brass
nickel-plated brass
nickel-plated brass
mini
mini
mini
mini
mini
mini
mini
mini
polyurethane No
Yes
No
No
No
Yes
Yes
Yes
polyurethane
polyurethane
polyurethane
polyurethane
polyurethane
polyurethane
polyurethane
JTBS-49-E433
JTBS-49-E434
JTBS-49-E633
JTBS-49-E634
4
4
6
6
euro
euro
euro
euro
stainless steel
nickel-plated brass
stainless steel
nickel-plated brass
No
No
No
No
Part Number
polyurethane
polyurethane
polyurethane
polyurethane
JTBS-49SC-E433
JTBS-49SC-E434
JTBS-49SC-E633
JTBS-49SC-E634
4
4
6
6
euro
euro
euro
euro
stainless steel
nickel-plated brass
stainless steel
nickel-plated brass
polyurethane
polyurethane
polyurethane
polyurethane
Yes
Yes
Yes
Yes
2
Quick Selection Guide
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588024
The junction box is available with short circuit protectionand is FM Approved for Cl 1, Div 2 hazardous locations.The rugged, fully encapsulated die-cast aluminum enclosureis available with stainless steel connectors.
minifast® Passive Multiport Junctions (Bricks)
For nickel-plated brass receptacles change part number to -Mxx4. Example: JBBS-49-M413 to JBBS-49-M414For fiberglass housing change part number to -Mx2x. Example: JBBS-49-M613 to JBBS-49-M623
JBBS-49-M813 JBBS-49-M613 JBBS-49-M413
Applications
Description
* JBBS-49SC-M413 overall dimensions 7.3mm X 2.52mm
Short Circuit Protection (only available with SC models)
Electrical♦ Short Circuit Protection: 55mA(Isc)♦ Voltage Open Circuit: 35VDC♦ Current Consumption: 5mA
Diagnostic♦ LED Indication:
Green LED - Bus PowerRed LED - Short Circuit Indication
Cl 1, DIV 2; Groups A-D See InterlinkBT drawing N1-2.400 T6, Ta = 70 degrees C
SC models only
Dimensions /Part Number
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588825
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
JBBS-49-M813
JBBS-49-M613
JBBS-49-M413
JBBS-49-M814
JBBS-49-M614
JBBS-49-M414
JBBS-49-M823
JBBS-49-M623
Num
ber o
f Por
ts
Con
nect
or S
ize
Hou
sing
Mat
eria
l
Con
nect
or M
ater
ial
Shor
t Circ
uit P
rote
cted
4
4
4
6
6
6
6
stainless steel
JBBS-49-M423
JBBS-49-M824
JBBS-49-M624
JBBS-49-M424
8
8
8
8
4
stainless steel
stainless steel
nickel-plated brass
stainless steel
stainless steel
stainless steel
mini
mini
mini
mini
mini
mini
mini
aluminum
aluminum
aluminum
fiberglass
aluminum
aluminum
aluminum
fiberglass
fiberglass
fiberglass
fiberglass
fiberglass
No
No
No
No
No
No
No
No
No
No
No
No
nickel-plated brass
nickel-plated brass
nickel-plated brass
nickel-plated brass
nickel-plated brass
mini
mini
mini
mini
mini
JBBS-49SC-M813
JBBS-49SC-M613
JBBS-49SC-M413
6
stainless steel8
4
stainless steel
stainless steel
mini
mini
aluminum
aluminum
aluminum
mini
Yes
Yes
Yes
Part Number2
Quick Selection Guide
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588026
Dimensions /
JBBS-49-E813 JBBS-49-E613 JBBS-49-E413
eurofast® Passive Multiport Junctions (Bricks)
For nickel-plated brass receptacles change part number to -Exx4. Example: JBBS-49-E413 to JBBS-49-E414For fiberglass housing change part number to -Ex2x. Example: JBBS-49-E613 to JBBS-49-E623
Part Number
Applications
Description
8, 6, and 4-Port Junction Bricks♦ bus-in / bus-out straight throughports♦ spurs with eurofast® connectors
Rugged, fully encapsulated die-cast aluminum brick with eurofast® connectors.
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588827
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
4
JBBS-49-E813
JBBS-49-E613
JBBS-49-E413
JBBS-49-E814
JBBS-49-E614
JBBS-49-E414
JBBS-49-E823
JBBS-49-E623
JBBS-49-E423
JBBS-49-E824
JBBS-49-E624
8
8
8
6
6
6
4
4
JBBS-49-E424
stainless steel
stainless steel
stainless steel
stainless steel
stainless steel
stainless steel
8
6
4
euro
euro
euro
euro
euro
euro
aluminum
aluminum
aluminum
aluminum
aluminum
aluminum
fiberglass
fiberglass
fiberglass
fiberglass
fiberglass
fiberglass
No
No
No
No
No
No
No
No
No
No
No
No
nickel-plated brass
nickel-plated brass
nickel-plated brass
nickel-plated brass
nickel-plated brass
nickel-plated brass
euro
euro
euro
euro
euro
euro
Num
ber o
f Por
ts
Con
nect
or S
ize
Hou
sing
Mat
eria
l
Con
nect
or M
ater
ial
Shor
t Circ
uit P
rote
cted
Part Number 2
Quick Selection Guide
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588028
FSV 49-*M / 14.5 FSV 49-*M / M20
RSFV 49-*M / M20
minifast® eurofast®
24.6 [0.97]
M12x1-6gM20x1.5-6g
RSFV 49-*M / 14.5
1/2 - NPT
M20
eurofast® minifast®
FSV 49-*M / 14.5 RSFV 49-*M / 14.5
FSV 49-*M / M20 RSFV 49-*M / M20
Device Gland Receptacles - 3 wireSelection Guide
9.5 [0.37]
28.5 [1.12]
M20x1.5-6g
1. Blue (-Voltage)2. Brown (+ Voltage)3. N/C4. Green/Yellow (Ground)
1.023 [26.0]
1/2-14NPT
.512 [13.0]
M12x1 .984 [25.0]
1.162 [29.5]
7/8-16UNC
.493[12.5]
.295 [7.5]
1/2-14NPT7/8-16UNC
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588029
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
FSV 49T-*M / 14.5 FSV 49T-*M / M20
RSFV 49T-*M / M20
minifast® eurofast®
24.6 [0.97]9.5 [0.37]
M12x1-6gM20x1.5-6g
RSFV 49T-*M / 14.5
1/2 - NPT
M20
eurofast® minifast®
FSV 49T-*M / 14.5 RSFV 49T-*M / 14.5
FSV 49T-*M / M20 RSFV 49T-*M / M20
Device Gland Receptacles - 2 wireSelection Guide
9.5 [0.37]
28.5 [1.12]
M20x1.5-6g
1. Blue (-Voltage)2. Brown (+Voltage)3. N/C4. N/C
1.023 [26.0]
1/2-14NPT
.512 [13.0]
M12x1 .984 [25.0]
1.162 [29.5]
7/8-16UNC
.493[12.5]
.295 [7.5]
1/2-14NPT 7/8-16UNC
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588030
RSV 49-TR
RSEV 49-TR
eurofast® Terminating Resistor
♦ internal resistor and capacitor
♦ male eurofast® connector
minifast® Terminating Resistor
♦ internal resistor and capacitor
♦ male minifast® connector
For nickel-plated brass coupling nuts change part number:
RSV 49-TR to RSM 49-TRRSEV 49-TR to RSE 49-TR
Dimensions Pinout
Dimensions Pinout
Terminating Resistors
1µF
100Ω
1µF
100Ω
Terminate at the beginning and endof each segment.
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588031
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
CROUSE - HINDS Hub Size = 3/4
Shape
C
LB
LL
LR
Style
Form 8Mark 9
Form 8Mark 9
Form 8Mark 9
Form 8Mark 9
Part Number
C28C29
LB28LB29
LL28LL29
LR28LR29
Dimensions
Description
Conduit Adapter
1-po
rt2-
port
BCA 49-M223
BCA 49-M123
BCA 49-E223
BCA 49-E123
eurofast®minifast®
Conduit connectors for use with armorfast® cable O-Z Gedney JMC-50-71 1/2NPT
47.5 [1.87]
131.4 [1.87]
110.5 [4.35]
The conduit adapter attaches to a standard conduitbody for transition to minifast® or eurofast® connectors.
optional terminating resistor
Conduit Bodies
♦ Gasket and mounting hardware included (8-32 x 1/2”)
2
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588032
Dimensions
FOUNDATION™ Fieldbus Tees
Part Number
minifast® tee♦ data, ground, shield♦ stainless steel coupling nuts
minifast® to eurofast® drop♦ data, ground, shield♦ stainless steel coupling nuts
RSV 2RKV 49
RSV FKV RKV 49
For nickel-plated brass coupling nuts:Change part number (RSV 2RKV ... RSM 2RKM ...)
DimensionsPart Number
RSCV 2RKCV 49
Description
eurofast® tee
Description
For nickel-plated brass coupling nuts:Change part number (RSCV 2RKCV ... RSC 2RKC ...)
♦ stainless steel coupling nuts
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588033
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
SPTT1-A49 SPTTM13-A49
Wire Table
Pin Designation Color
1
2
3
4
V -
V +
Shield
Ground
Blue
Brown
Bare
Green/Yellow
Field Wireable Tee
The Field Wireable Tee is a hybrid connection offering system-wide “plug-and-play” convenience.This allows an extremely rapid changeover to a connectorized network, often in less than 15minutes. The Field Wireable IP67 Tee features standardized minifast® connectors for the dropconnection and field wireable terminals on the trunk connections. This provides the best of bothworlds, reliable connections on the short lengths and ease of installation planning on the long trunkruns.
Description
Specifications
Dimensions
2
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588034
Dimensions
minifast® Male Gender Changer♦ female cordset to male receptacle
minifast® Female Gender Changer♦ male cordset to female receptacle
minifast® Elbow♦ right angle male to
female connector
♦ minifast® male to eurofast® female connector
Part Number
Gender Changers and Elbow Connectors
For nickel-plated brass coupling nuts:Change part number (RSV RSV...RSM RSM...)* = Consult factory for availability.
minifast® to eurofast® Adapter
RSV RSV 49
RKV RKV 49
WSV RKV 49
RSM 49-FK 4.5*
Description
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588035
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Mechanical
This surge suppressor protects the data communication lines (V+ and V-) rather than just the shield.The unique multi-stage design provides superior surge protection. The surge suppressor absorbs thefront end of the transient, responding in less than a nanosecond, then diverts the surge energy toground. Once the surge has been dissipated the suppressor automatically resets and waits for thenext surge.
The minifast® connectors provide IEC IP67 protection in the rugged polyurethane overmoldedbody. The surge suppressor is available with stainless steel coupling nuts and a ground stud.
Electrical♦ Maximum Operating Voltage: 27 Volts♦ Maximum Operating Current: 200mA♦ Clamping Action Turn-On: 28.5 Volts♦ Maximum Clamping at 2 kA: : 44 Volts♦ Maximum Surge Voltage: 20 kV♦ Maximum Surge Current: 2.5kA♦ Current Leakage/Line At Operating Voltage: 5µA♦ Capacitance/Line At Operating Voltage: 500pF♦ Response Time: Less than 1 nanosecond
(8 X 20 µSec)
Specifications
Description
Dimensions
♦ Ground Stud: 10-32 Stainless Steel♦ Operating Temperature: -40°C to +85°C
Surge Suppressor
RSV RKV 49 SS
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588036
The Power Supply Conditioner meets the needs of redundant power supplies for FOUNDATION™Fieldbus. This product has primary and secondary power inputs to supply two Fieldbus H1segments. Standard 24VDC power feeds into supplies A and B. It also takes care of filtering thefieldbus signal from the power source. LED’s indicate which Power Supply is primary andsecondary. Diagnostics provide the status of each power supply, indicating either READY orACTIVE. The status is also provided through relay outputs for further monitoring. Internalswitches turn on/off terminators per segment.
Supply “A” is Primary. If Supply “A” Voltage drops below 11 V, Supply “B”becomes ActiveSupply “A” becomes Active once Voltage >11V
Solid State, AC/DC <400 V, <70 mA when supply Voltage >11V, Contact Is Closed♦ Supply Monitor Contacts (Supply A & B):
♦ Output Voltage (Segment 1 & 2): Input Voltage - 3 Volts♦ Output Current (Segment 1 & 2): <1A♦ Short Circuit Protection (Segment 1 & 2): >1A to Infinite
Diagnostic♦ Power LED Indications:♦ Segment LED Indications:
Green - Active / Red - No PowerGreen - Active
Electrical♦ Supply Voltage (Supply A & B): 12 - 32 VDC♦ Supply Surge Protection (Supply A & B): >36 VDC♦ Supply Redundancy (Supply A & B):
Description
Specifications
BRPC-49-M213
Power Supply Conditioner
Dimensions
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588037
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
The JTBS-49SC-M633 short circuit brick is classified as nonincendive equipment. This meansthat it is considered nonarcing under normal operating conditions. In a fieldbus system, the trunkdoes not need to be serviced under normal operating conditions. The trunk connections (P1 andS0) are to be locked with a Lokfast™ Guard to mechanically prevent separation.
Description
Specifications
Mechanical♦ Dimensions: 43mm X D/A X 39mm
♦ Material: Nylon 6
♦ Environmental: Sun Resistant, UV Stable
♦ Operating Temperature: -30ºC to 100ºC
♦ Flammability: UL94 (5=V-0; 4=V-1; 3=V-2; 1=HB)
SHLD, MINI FW - available for field wireable connectors
SHLD, MINI (10/bag)
eurofast®minifast®
Stan
dard
Fiel
d W
ireab
le
SHLD, MINI FW SHLD, EURO FW
SHLD, MINI SHLD, EURO
Assembly/Disassembly
Lokfast™ Guard
2
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588038
Bulkhead Feed-Thru Receptacles
RSFV RKFV 49/22
FKV FSV 49/M12
For nickel-plated brass coupling nuts change part number:RSFV RKFV 49/22 to RSF RKF 49/22
orFKV FSV 49/M12 to FKM FS 49/M12
minifast® Bulkhead Receptacle♦ straight male/female feed-thru
eurofast® Bulkhead Receptacle♦ straight male/female feed-thru .500
12.7
.1253.2
.0621.6
.87522.5
Panel Cutout
Panel Cutout
Dimensions
Dimensions
For jam nuts or spare nuts order:LN-SS 1/2-14[10/BAG] or LN-SS12[10/BAG]
panel mount
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588039
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Panel Mount Receptacles - minifast® , eurofast®
RKFV 49 - *M RSFV 49 - *M
FKV 49 - *M FSV 49 - *Meurofast®
minifast®
Selection Guide Female Male
Female eurofast®
RKFV 49 RSFV 49
FKV 49 FSV 49
eurofast®
minifast®
Lea
dsCa
ble RKFV 490 - *M RSFV 490 - *M
FKV 490 - *M FSV 490 - *M
Part numbers on diagrams represent solder cups only.
1. Blue (-Voltage)2. Brown (+ Voltage)3. Bare (Shield Drain Wire)4. Green/Yellow (Ground)
2
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588040
B 4149-0/9 BS 4149-0/9
BSV 4149-0/9BV 4149-0/9
Male Female
Field Wireable Connectors - minifast®Aluminum Stainless SteelSelection Guide
BV 4149-0/9
BSV 4149-0/9
B 4149-0/9
BS 4149-0/9
Female
Male
1. Blue (-Voltage)2. Brown (+ Voltage)3. Bare (Shield Drain Wire)4. Green/Yellow (Ground)
x - coupling nuthousing material - nylon
x x
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588041
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
B8141-0 B8241-0
BS8141-0 BS8241-0
Straight Right Angle
Male
Female
Field Wireable Connectors - eurofast®Selection Guide
B8141-0 B8241-0
BS8141-0 BS8241-0
female eurofast®
Rating: 3 A, 36 VDCRating: 3 A, 36 VDC
male eurofast®1. Blue (-Voltage)2. Brown (+ Voltage)3. Bare (Shield Drain Wire)4. Green/Yellow (Ground)
2
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588042
Description
Dimensions
Closure caps are for unused ports on the junction box.
Closure Cap
RSMV BC
RKMV BC
♦ Stainless steel♦ IP67 rated
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588043
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
PROFIBUS®-PA Cables and Accessories
3
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588044
PROFIBUS®-PAPROFIBUS®-PA (Process Automation) uses synchronous transfer mode technology, as defined in IEC 61158-2, tocommunicate between field devices and the RS 485 backbone of PROFIBUS®-DP. A segment coupler, or gateway isinstalled to bridge PROFIBUS®-DP with PROFIBUS®-PA. Otherwise, the protocols are identical, allowing transparentcommunication between general purpose automation systems and decentralized field devices.
PROFIBUS®-PA is a master-slave bus. Transmitters used in the process industry are typically slave devices or passivestations which only communicate at the request of the master.
General Layout TopologiesThe topology for PROFIBUS®-DP is a linear bus. Branching can be accomplished with repeaters or, in the case ofPROFIBUS®-PA, this can be accomplished with the segment couplers. The PROFIBUS®-PA topology follows thephysical layer as defined in ISA SP50.02. Daisy Chain or Star topologies are allowed.
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588045
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Star Topology MethodA Star topology has a central connection point to all terminations. This layout works well when there are many devices in alocalized area. For instance, the control room may be located about 300 meters away from a cracker tower. This tower mayhave five or six temperature transmitters. All of these devices need to be connected to the fieldbus segment. The best designwould be to connect them all to a junction brick and then run a Home Run cable from the junction brick back to the controlroom. See Figure 4 for a pictorial example.
The Home Run cable is considered the main trunk line of communication. Each device that is connected to the junctionbrick is called a spur. In other industrial networks spurs are called drops off the trunk line.
Figure 4 - Star Topology Example
Daisy Chain ConfigurationAnother layout design is to daisy chain all the devices. Each device would require a tee so that the Home Run cablewould be able to go to each device. From a design standpoint, the Daisy Chain method is easiest to do when the exactcable tracks are known. Pre-made cordsets can then be purchased and the network is easy to assemble. See Figure 5 foran example drawing. A fieldbus transmitter is connected to each of the tanks in the field. The Home Run cable essen-tially is routed to each device in series.
In many fieldbus installations it makes sense to mix both Star and Daisy Chain topology layouts. Remember that one of thebenefits to fieldbus is reduced wiring of devices, leading to faster start-up times.
Figure 5 - Daisy Chain LayoutTransmitters
3
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588046
Fieldbus Cable SpecificationsThe specifications for PROFIBUS®-PA physical media are defined by IEC 1158-2 and the ISA-S50.02 Part 2 PhysicalLayer Standards. There are essentially four types of cable designations for fieldbus. Type A cable is the most preferredfor new installations because it allows for the most versatile lengths. The other types of cable are for installations wherecable already exists from 4-20 mA systems. See Table 1.
Type Cable Description Conductor Size Maximum Length
Type A
Type B
Type C
Type D
Shielded, Twisted Pair
Shielded, Multi Twisted Pair
Shielded, Untwisted Pair
Unshielded, Multi Twisted Pair
# 18 Awg
# 22 Awg
# 26 Awg
# 16 Awg
1900 m (6232 ft)
1200 m (3936 ft)
400 m (1312 ft)
200 m (656 ft)
InterlinkBT offers both a three conductor and two conductor with the third conductor available for a centralized groundof devices if needed. InterlinkBT cables meet or exceed the specifications of ANSI/ISA-SP50.02-1992, the fieldbusstandard for use in industrial control systems.
Table 1 Fieldbus Cable Specifications
Cable SpecificationsType A Cable- Designed for harsh environments- Temperature range of -50 to 105°C(-58 to +221F)- Governed by: ISA SP50.02 specification- Sunlight resistant per test- PLTC and ITC rated (CSA FT4)- Impedence[Z0 at f r (31.25 kHz)] = 100Ω ± 20%- Maximum attenuation at 1.25 fr (39 kHZ) = 3.0 dB/km- Maximum capacitive unbalance to shield = 2 nF/km- Maximum DC resistance (per conductor) = 24 Ω/km- Maximum propagation delay change 0. 25 fr to 1.25 fr = 1.7 µs/km- Conductor cross-sectional area (wire size) = nominal 0.8 mm2 (#18 AWG)- Minimum shield coverage shall be 90%
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588047
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Our cable meets requirements of ISA/SP50 andPROFIBUS®-PA Type A cable. All cables arerated -40ºC to 105ºC and are sunlight resistant.Available in 3-wire versions with a deviceground or 2-wire versions.
Type ApprovalData Pair
AWGColor Code
DCR (/1000 ft)Insulation
Device Ground
AWG Color Code
Outer JacketMaterial ColorNominal O.D.
ShieldsType
Drain Wire
NetworkStandard
483
483B
482A
482BA
2/18 AWGBlue/Brn
2/18 AWGBlue/Brn
2/18 AWGBlue/Brn
2/18 AWGBlue/Brn
None
None
18 AWGGreen/Yellow
18 AWGGreen/Yellow
PVC Orange7.9mm (.310 in)
PVC Blue7.9mm (.310 in)
Armor/PVC Orange12.7mm (0.5 in)
Armor/PVC Blue12.7mm (0.5 in)
Foil/Braid20 AWG
Foil18 AWG
Foil/Braid20 AWG
Foil18 AWG
ISA / SP50
ISA / SP50
ISA / SP50
ISA / SP50
OverallFoil Shield
DataBlue
Brown
Device GroundGreen/Yellow
DataBlue
Brown
Ref.
A
B
ITC PLTC300V [CMG]
ITC PLTC300V [CMG]
ITC PLTC300V [CMG]
ITC PLTC300V [CMG]
UL [CSA]
6.5 OhmsPE
6.5 OhmsPE
6.5 OhmsPE
6.5 OhmsPE
A
A
B
B
483BK 2/18 AWGBlue/Brn
None PVC Black7.9mm (.310 in)
Foil/Braid20 AWG ISA / SP50
ITC PLTC300V [CMG]
6.5 OhmsPE
A
Trunk
1900 m
Cable
25 - 3219 - 2415 - 1813 - 142 - 12
0 m (0 ft)30 m (98 ft)60 m (197 ft)90 m (295 ft)120 m (394 ft)
# of Devices Max Spur Length
PROFIBUS®-PA - Cable Specifications
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588048
Sock
et (F
emal
e)So
cket
(Fem
ale)
Pin
(Mal
e)Pi
n (M
ale)
Pin (Male) Socket (Female) Pin (Male)
RSV
WSV
RSV
RKV
WSV
WKV
RKV
RSCV
WKV
WSCV
RKCV
WKCV
RSCV
RSV 48 - *M
RSV RSV 48 -*M
WSV 48 -*M RKV 48 -*M WKV 48 -*M
RSV WSV 48 -*M RSV RKV 48 -*M RSV WKV 48 -*M
WSV WSV 48 -*M WSV RKV 48 -*M WSV WKV 48 -*M
RKV RKV 48 -*M RKV WKV 48 -*M
WKV WKV 48 -*M
×
×
×
×
×
×
×
×
× ×
×
×× ×
×
×
×
×
×
×RSCV 48 -*M
RSV RSCV 48 -*M
WSV RSCV 48 -*M
RKV RSCV 48 -*M
WKV RSCV 48 -*M
RSCV RSCV 48 -*M
PROFIBUS®-PA - Cables and Cordsets
min
ifast®
♣♣♣♣ ♣eu
rofa
st®**
eurofast®**minifast®♣♣♣♣♣
WSV RSCV 482-*M× Indicates cable type
Indicates length in metersStandard cable onlyArmorfast® cable onlyFor nickel-plated brass coupling nut: RSV...to RSM...
RSCV...to RSC...
***♣♣♣♣♣
Bulk cable, see page 8 for standard lengths
Example
48 -*M×
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588049
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Pin (Male)Pin (Male)Pin (Male) Socket (Female) Socket (Female)
WSCV RKCV WKCV RSFPV RKFPV FSFDV FKFDV
WSCV 48 -*M RKCV 48 -*M WKCV 48 -*M RSFPV 48 -*M RKFPV 48 -*M FSFDV 48 -*M FKFDV 48 -*M
RSV WSCV 48 -*M RSV RKCV 48 -*M RSV WKCV 48 -*M RSV RSFPV 48 -*M RSV RKFPV 48 -*M RSV FSFDV 48 -*M RSV FKFDV 48 -*M
WSV WSCV 48 -*M WSV RKCV 48 -*M WSV WKCV 48 -*M WSV RSFPV 48 -*M WSV RKFPV 48 -*M WSV FSFDV 48 -*M WSV FKFDV 48 -*M
RKV WSCV 48 -*M RKV RKCV 48 -*M RKV WKCV 48 -*M RKV RSFPV 48 -*M RKV RKFPV 48 -*M RKV FSFDV 48 -*M RKV FKFDV 48 -*M
WKV WSCV 48 -*M WKV RKCV 48 -*M WKV WKCV 48 -*M WKV RSFPV 48 -*M WKV RKFPV 48 -*M WKV FSFDV 48 -*M WKV FKFDV 48 -*M
RSCV WSCV 48 -*M RSCV RKCV 48 -*M RSCV WKCV 48 -*M RSCV RSFPV 48 -*M RSCV RKFPV 48 -*M RSCV FSFDV 48 -*M RSCV FKFDV 48 -*M
WSCV WSCV 48 -*M WSCV RKCV 48 -*M WSCV WKCV 48 -*M WSCV RSFPV 48 -*M WSCV RKFPV 48 -*M WSCV FSFDV 48 -*M WSCV FKFDV 48 -*M
RKCV RKCV 48 -*M RKCV WKCV 48 -*M RKCV RSFPV 48 -*M RKCV RKFPV 48 -*M RKCV FSFDV 48 -*M RKCV FKFDV 48 -*M
WKCV WKCV 48 -*M WKCV RSFPV 48 -*M WKCV RKFPV 48 -*M WKCV FSFDV 48 -*M WKCV FKFDV 48 -*M
×
×
×
×
×
×
× ×
×
×
×
×
× × × ×
× × × ×
× × ×
× × ×
×
×
× × × ×
× × × ×
× × × ×
× × ×
× ×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
PROFIBUS®-PA - Cables and Cordsets
minifast® bulkheadeurofast® eurofast® bulkhead
Socket (Female)
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588050
1. Brown (+ Voltage)2. N/C3. Blue (- Voltage)4. Bare (Shield Drain Wire)
MALE FEMALE
RSFPV-* RKFPV-* Mounting Installation
5.0
1.8
30.5
RSV-* RKV-*
WSV-* WKV-*
minifast® Cordset and Receptacle Connector Dimensions and Pinouts
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588051
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
RSCV-* RKCV-*
WSCV-* WKCV-*
FEMALEMALE
Mounting InstallationFSFDV-* FKFDV-*
eurofast® Cordset and Receptacle Connector Dimensions and Pinouts
1. Brown (+ Voltage)2. N/C3. Blue (- Voltage)4. Bare (Shield Drain Wire)
3
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588052
Short Circuit minifast® Junction Tee
Specifications
Description
Dimensions
JTBS-48SC-M633
Short Circuit Protection (only available with SC models)
Electrical♦ Short Circuit Protection: 55mA(Isc)♦ Voltage Open Circuit: 35VDC♦ Current Consumption: 5mA
Diagnostic♦ LED Indication:
Green LED - Bus PowerRed LED - Short Circuit Indication
The PROFIBUS®-PA junction tee is available with short circuit protection.Mechanically rugged, the new overmolded design provides unparalled corrosiveresistance.
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588053
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
JTBS-48-M433
JTBS-48-M434
JTBS-48-M633
JTBS-48-M634
JTBS-48SC-M433
JTBS-48SC-M434
JTBS-48SC-M633
JTBS-48SC-M634
Num
ber o
f Por
ts
Con
nect
or S
ize
Ove
rmol
d M
ater
ial
Con
nect
or M
ater
ial
Shor
t Circ
uit P
rote
cted
4
4
4
4
6
6
6
6
stainless steel
Part Number
mini
mini
mini
mini
mini
mini
mini
mini
stainless steel
stainless steel
stainless steel
nickel-plated brass
nickel-plated brass
nickel-plated brass
nickel-plated brass
No
No
No
No
Yes
Yes
Yes
Yes
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
JTBS-48-E433
JTBS-48-E434
JTBS-48-E633
JTBS-48-E634
JTBS-48SC-E433
JTBS-48SC-E434
JTBS-48SC-E633
JTBS-48SC-E634
4
4
4
4
6
6
6
6
stainless steeleuro
euro
euro
euro
euro
euro
euro
euro
stainless steel
stainless steel
stainless steel
nickel-plated brass
nickel-plated brass
nickel-plated brass
nickel-plated brass
No
No
No
No
Yes
Yes
Yes
Yes
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Quick Selection Guide
3
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588054
minifast® Passive Multiport Junctions (Bricks)
For nickel-plated brass receptacles change part number to -Mxx4. Example: JBBS-48-M413 to JBBS-48-M414For fiberglass housing change part number to -Mx2x. Example: JBBS-48-M613 to JBBS-48-M623
JBBS-48-M813 JBBS-48-M613 JBBS-48-M413
Applications8, 6, and 4-Port Junction Bricks♦ bus-in / bus-out straight throughports♦ drops with minifast® connectors
Dimensions /Part Number
Description
Keyed for PROFIBUS®-PA SystemsRugged, fully encapsulated die-cast aluminum enclosuresBus-In/Bus-Out eliminate need for splitter teeProvide common ground for all devicesStainless steel receptacles
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588055
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Num
ber o
f Por
ts
Con
nect
or S
ize
Hou
sing
Mat
eria
l
Con
nect
or M
ater
ial
Shor
t Circ
uit P
rote
cted
4
4
4
6
6
6
6
stainless steel
8
8
8
8
4
stainless steel
stainless steel
nickel-plated brass
stainless steel
stainless steel
stainless steel
mini
mini
mini
mini
mini
mini
mini
aluminum
aluminum
aluminum
fiberglass
aluminum
aluminum
aluminum
fiberglass
fiberglass
fiberglass
fiberglass
fiberglass
No
No
No
No
No
No
No
No
No
No
No
No
nickel-plated brass
nickel-plated brass
nickel-plated brass
nickel-plated brass
nickel-plated brass
Part Number
mini
mini
mini
mini
mini
JBBS-48-M813
JBBS-48-M613
JBBS-48-M413
JBBS-48-M814
JBBS-48-M614
JBBS-48-M414
JBBS-48-M823
JBBS-48-M623
JBBS-48-M423
JBBS-48-M824
JBBS-48-M624
JBBS-48-M424
Quick Selection Guide
3
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588056
JBBS-48-E813 JBBS-48-E613 JBBS-48-E413
eurofast® Passive Multiport Junctions (Bricks)
For nickel-plated brass receptacles change part number to -Exx4. Example: JBBS-48-E413 to JBBS-48-E414For fiberglass housing change part number to -Ex2x. Example: JBBS-48-E613 to JBBS-48-E623
Part Number
Applications
Description
8, 6, and 4-Port Junction Bricks♦ bus-in / bus-out straight throughports♦ spurs with eurofast® connectors
Keyed for PROFIBUS®-PA SystemsRugged, fully encapsulated die-cast aluminum enclosuresBus-In/Bus-Out eliminate need for splitter teeProvide common ground for all devicesStainless steel receptacles
Dimensions /
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588057
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
4
8
8
8
6
6
6
4
4
stainless steel
stainless steel
stainless steel
stainless steel
stainless steel
stainless steel
8
6
4
euro
euro
euro
euro
euro
euro
aluminum
aluminum
aluminum
aluminum
aluminum
aluminum
fiberglass
fiberglass
fiberglass
fiberglass
fiberglass
fiberglass
No
No
No
No
No
No
No
No
No
No
No
No
nickel-plated brass
nickel-plated brass
nickel-plated brass
nickel-plated brass
nickel-plated brass
nickel-plated brass
euro
euro
euro
euro
euro
euro
Num
ber o
f Por
ts
Con
nect
or S
ize
Hou
sing
Mat
eria
l
Con
nect
or M
ater
ial
Shor
t Circ
uit P
rote
cted
Part Number
JBBS-48-E813
JBBS-48-E613
JBBS-48-E413
JBBS-48-E814
JBBS-48-E614
JBBS-48-E414
JBBS-48-E823
JBBS-48-E623
JBBS-48-E423
JBBS-48-E824
JBBS-48-E624
JBBS-48-E424
Quick Selection Guide
3
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588058
FSV 48T-*M / 14.5 FSV 48T-*M / M20
RSFV 48T-*M / M20
minifast® eurofast®
RSFV 48T-*M / 14.5
1/2 - NPT
M20
eurofast® minifast®
FSV 48T-*M / 14.5
FSV 48T-*M / M20 RSFV 48T-*M / M20
Device Gland Receptacles - 2 wireSelection Guide
RSFV 48T-*M / 14.5
1. Brown (+ Voltage)2. N/C3. Blue (- Voltage)4. N/C
24.6 [0.97]9.5 [0.37]
M12x1-6gM20x1.5-6g
9.5 [0.37]
28.5 [1.12]
M20x1.5-6g
1.023 [26.0]
1/2-14NPT
.512 [13.0]
M12x1 .984 [25.0]
1.162 [29.5]
7/8-16UNC
.493[12.5]
.295 [7.5]
1/2-14NPT 7/8-16UNC
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588059
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
RSV 48-TR
RSEV 48-TR
minifast® Terminating Resistor
♦ internal resistor and capacitor
♦ male connector
eurofast® Terminating Resistor
♦ internal resistor and capacitor
♦ male connector
Dimensions Pinout
Dimensions Pinout
Terminating Resistors
For nickel-plated brass change:RSEV 48-TR to RSE 48-TRRSV 48-TR to RSM 48-TR
1µF 100Ω
1µF 100Ω
Terminate at the beginning andend of each segment
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588060
minifast® Terminating Resistor
♦ internal resistor and capacitor
♦ male connector
eurofast® Terminating Resistor
♦ internal resistor and capacitor
♦ male connector
Dimensions Pinout
Dimensions Pinout
1µF 100Ω
1µF 100Ω
Terminating Resistors - Ex
For nickel-plated brass change:RSEV 48-TR-Ex to RSE 48-TR-ExRSV 48-TR-Ex to RSM 48-TR-Ex
Terminate at the beginning andend of each segment
RSV 48-TR-Ex
RSEV 48-TR-ExEx ApprovalBVS 99.E.2044XEntity Parameters:U0:I0:P0:Ta:
16.2V500mA1.8W-40ºC...+70ºC (EEx ia IIC T4)-40ºC...+70ºC (EEx ia IIC T6)
≥≥≥
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588061
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Dimensions
Description
Conduit Adapter
1-po
rt2-
port
BCA 48-M223
BCA 48-M123
BCA 48-E223
BCA 48-E123
eurofast®minifast®
Conduit connectors for use with armorfast® cable O-Z Gedney JMC-50-71 1/2NPT
47.5 [1.87]
131.4 [1.87]
110.5 [4.35] optional terminating resistor
The conduit adapter attaches to a standard conduitbody for transition to minifast® or eurofast® connectors.
Conduit Bodies
♦ Gasket and mounting hardware included (8-32 x 1/2”)
3
CROUSE - HINDS Hub Size = 3/4
Shape
C
LB
LL
LR
Style
Form 8Mark 9
Form 8Mark 9
Form 8Mark 9
Form 8Mark 9
Part Number
C28C29
LB28LB29
LL28LL29
LR28LR29
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588062
DimensionsPart Number Description
RSV 2RKV 48
RSV FKV RKV 48
DimensionsPart Number
minifast® tee♦ data, shield♦ stainless steel coupling nut
eurofast® drop♦ data, ground, shield♦ stainless steel coupling nut
eurofast® tee♦ stainless steel coupling nut
Description
RSCS 2RKCS 48
PROFIBUS®-PA Tees
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588063
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Field Wireable Tee
The Field Wireable Tee is a hybrid connection offering system-wide “plug-and-play” convenience.This allows an extremely rapid changeover to a connectorized network, often in less than 15minutes. The Field Wireable IP67 Tee features standardized minifast® connectors for the dropconnection and field wireable terminals on the trunk connections. This provides the best of bothworlds, reliable connections on the short lengths and ease of installation planning on the long trunkruns.
Description
SPTT1-A48
Specifications
Dimensions
Wire Table
Pin Designation Color
1
2
3
4
PA+
N/C
PA-
Shield
Brown
Blue
Drain
SPTT1-A48 SPTTM13-A48
3
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588064
minifast® to eurofast® Adapter
DimensionsPart Number Description
Selection Guide
For nickel-plated brass coupling nuts:Change part number (RSV RSV...RSM RSM...)* Consult factory for availability of stainless steel.
RSV RSV 48
RKV RKV 48
WSV RKV 48
RSM 48-FK 4.5*
minifast® Male Gender Changer♦ female cordset to male receptacle
minifast® Female Gender Changer♦ male cordset to female receptacle
minifast® Elbow♦ right angle male to female connector
♦ minifast® male to eurofast® female connector
Gender Changers and Elbow Connectors
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588065
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Mechanical
This surge suppressor protects the data communication lines (V+ and V-) rather than just the shield.The unique multi-stage design provides superior surge protection. The surge suppressor absorbs thefront end of the transient, responding in less than a nanosecond, then diverts the surge energy toground. Once the surge has been dissipated the suppressor automatically resets and waits for thenext surge.
The minifast® connectors provide IP67 protection in the rugged polyurethane overmolded body.The surge suppressor is available with stainless steel coupling nuts and ground stud.
Specifications
Description
Dimensions
♦ Ground Stud: 10-32 Stainless Steel♦ Operating Voltage: 24 Volts♦ Operating Temperature: -40°C to +85°C
Surge Suppressor
RSV RKV 48 SS
3
Electrical♦ Maximum Operating Voltage: 27 Volts♦ Maximum Operating Current: 200mA♦ Clamping Action Turn-On: 28.5 Volts♦ Maximum Clamping at 2 kA: : 44 Volts♦ Maximum Surge Voltage: 20 kV♦ Maximum Surge Current: 2.5kA♦ Current Leakage/Line At Operating Voltage: 5µA♦ Capacitance/Line At Operating Voltage: 500pF♦ Response Time: Less than 1 nanosecond
(8 X 20 µSec)
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588066
The JTBS 48SC–M633 short circuit brick is classified as nonincendive equipment. This meansthat it is considered nonarcing under normal operating conditions. In a fieldbus system, the trunkdoes not need to be serviced under normal operating conditions. The trunk connections (P1 andS0) are to be locked with a Lokfast™ Guard to mechanically prevent separation.
Description
Specifications
Mechanical♦ Dimensions: 43mm X D/A X 39mm
♦ Material: Nylon 6
♦ Environmental: Sun Resistant, UV Stable
♦ Operating Temperature: -30ºC to 100ºC
♦ Flammability: UL94 (5=V-0; 4=V-1; 3=V-2; 1=HB)
* SHLD, MINI FW - available for field wireable connectors
SHLD, MINI (10/bag)
eurofast®minifast®
Stan
dard
Fiel
d W
ireab
le
SHLD, MINI FW SHLD, EURO FW
SHLD, MINI SHLD, EURO
Assembly/Disassembly
Lokfast™ Guard
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588067
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
minifast® Bulkhead Receptacle♦ straight male/female feed-thru
eurofast® Bulkhead Receptacle♦ straight male/female feed-thru
Panel Cutout
Panel Cutout
Bulkhead Feed-Thru Receptacles
Dimensions
Dimensions
RSFV RKF 48/22
FKV FSV 48/M12
For nickel-plated brass coupling nuts change part number:RSFV RKFV 48/22 to RSF RKF 48/22
orFKV FSV 48/M12 to FKM FS 48/M12
panel mount
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588068
Panel Mount Receptacles - minifast®, eurofast®
RKFV 48 - *M RSFV 48 - *M
FKV 48 - *M FSV 48 - *Meurofast®
minifast®
Selection Guide Female Male
Female eurofast®
RKFV 48 - *M RSFV 48 - *M
FKV 48 - *M FSV 48 - *M
lead
s
1. Brown (+ Voltage)2. N/C3. Blue (- Voltage)4. Bare (Shield Drain Wire)
eurofast®
minifast®
cabl
e
RKFV 483 - *M RSFV 483 - *M
FKV 483 - *M FSV 483 - *M
eurofast®
minifast® RKFV 482 - *M RSFV 482 - *M
FKV 482 - *M FSV 482 - *M
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588069
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
B 4148-0/9 BS 4148-0/9
BSV 4148-0/9BV 4148-0/9
Male Female
Field Wireable Connectors - minifast®Aluminum Stainless SteelSelection Guide
BV 4148-0/9
BSV 4148-0/9
B 4148-0/9
BS 4148-0/9
Female
Male
x - coupling nuthousing material - nylon
x x
1. Brown (+ Voltage)2. N/C3. Blue (- Voltage)4. Bare (Shield Drain Wire)
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588070
female eurofast®
Rating: 3 A, 36 VDCRating: 3 A, 36 VDC
male eurofast®1. Brown (+ Voltage)2. N/C3. Blue (- Voltage)4. Bare (Shield Drain Wire)
B8141-0 B8241-0
BS8141-0 BS8241-0
Straight Right Angle
Male
Female
Field Wireable Connectors - eurofast®Selection Guide
B8141-0 B8241-0
BS8141-0 BS8241-0
Field wireable connectors for bus lines and dropsFacilitate field replacement
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588071
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Description
Dimensions
Closure caps are for unused ports on the junction box.
Closure Cap
RSMV BC
RKMV BC
♦ Stainless steel♦ IP67 rated
3
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588072
HART® Cables and Accessories
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588073
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
HART® Overview
HART® (Highway Addressable Remote Transducer) is a 4-20 mA protocol which supports two-way digital communicationfor process measurement and control devices. Although it is not an international standard, it is considered an “open”protocol, broadly accepted in the process industry. HART® devices can store process related information and communicatedigitally. It can also be used with traditional 4-20 mA devices. This is beneficial if there is a large existing installed base of4-20 mA transmitters.
HART® is a master-slave protocol. This meansthat when the master calls out the slave’s address,the slave responds. The master takes control of thetime and operational sequence of the bus. Therecan be two masters, including a hand-held commu-nicator. Up to 15 slave devices can be connectedto one multidrop line (limitations exist for intrinsi-cally safe areas).
HART® uses the Bell 202 standard frequency shiftkeying (FSK) for digital communication. The FSKsignal is superimposed on the 4 to 20 mA analogmeasurement signal. The FSK signal does not cause interference with the analog measurement since the average value iszero. The frequency of 1200 hz is used for a logical ‘1’ and 2200 hz is used for a logical ‘0’.
General Layout Topologies
Field wiring of HART® uses twisted pair cable, either screened as a pair in a cable or multiple screens and an overall screenon cable containing multiple pairs. There are two basic structures for wiring a system. The first is point-to- point wiring.This means that every pair that connects to an instrument is returned to the control, completely isolated from the other pairs.This can either be accomplished with twisted pair cable or a bundled multiple pair cable. See Figure 6. The second type ofstructure is multidrop wiring. This can be used when the HART® enabled transmitters are operating in digital communica-tion only. The transmitters may be wired with a trunk and drop layout(or a Daisy Chain). See Figure 7. Either of thesemethods greatly reduce wiring and allow for the most flexibility in expansion.
Figure 6 - Point-to-Point Example
Figure 7 - Multidrop Example
4
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588074
HART® simulation software to determine maximum lengths can be found at www.romilly.co.uk. The software H-SIMcan be downloaded free of charge.
H40H120H190HM40
2 X 22 AWG + 20 Device Ground4 Pair, 2 X 22 AWG + 18 AWG Device Ground8 Pair, 2 X 22 AWG + 18 AWG Device Ground2 X 18 AWG + Device Ground
150 pF/m190 pF/m260 pF/m140 pF/m
112Ω/1000 m112Ω/1000 m112Ω/1000 m43Ω/1000 m
Cable Type Description Capacitance Pair Resistance
(µF)
Maximum Cable Length250 ohm Load Resistor
HART® Cable Specifications
Ω
Ω
H40H120H190HM40
Length (meters)
Dev
ice
CTo
tal
0 500 1000 15000.00
0.10
0.20
0.30
The maximum HART® cable length is 1500 meters. However, the physical media is limited by a maximum systemattenuation of 3 dB. This is ensured if there is a resistance-capacitance combination having an RC time-constant value of65 µF (the circuit resistance R divided by the capacitance C). The system design must consider both resistance of thedevice and the cable, likewise the capacitance of the device and the cable. In a typical system the host load resistance is250 . HART® recommends a maximum capacitance of 5000 pF on slave devices. Devices with higher capacitancemust list the capacitance number (CN). This number equals the actual device capacitance divided by 5000 pF. Forexample, a device with a capacitance of 10,000 pF would have CN = 2.
Resistance is measured for both conductors in series. Capacitance is measured from one conductor to all others and thescreen. The values for InterlinkBT cables are as follows:
The maximum cable distance is dependent on the cable type and the total capacitance of the devices. The graph belowprovides guidelines for cable distances based on the standard InterlinkBT cable and assuming a 250 load resistor. Inthe example if the system consisted of 9 devices with an average CN of 2 (i.e. 10,000 pF each) and a host with 5000 pFcapacitance, which totals 0.095 µF (95,000 pF), the maximum cable length would be 900 meters using multidrop struc-ture cable HM40.
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588075
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
4
ApprovalSingle Pairs
AWGColor Code
DCR (/1000 ft)Insulation
Device Ground
AWG Color Code
Outer JacketMaterial ColorNominal O.D.
ShieldsType
Drain Wire
NetworkStandard
PLTC300V [CMG]
ITC PLTC300V [CMG]
PLTC300V or CM
[CMG HLBCD]
ITC PLTC300V [CMG]
2/22 AWGBlue/Brn
2/18 AWGBlue/Brn
4 Pairs2/22 AWG
2/18 AWGBlue/Brn
16.5 OhmsPE
6.5 OhmsPE
16.5 OhmsPE
16.5 OhmsPE
6.5 OhmsPE
20 AWGGreen/Yellow
18 AWGGreen/Yellow
18 AWGGreen/Yellow
18 AWGGreen/Yellow
None
PVC Grey7.2mm (.285 in)
Armor/PVC Grey7.9mm (.310 in)
PVC Grey12.7mm (0.5 in)
PVC Grey7.9mm (.310 in)
PVC Grey12.7mm (0.5 in)
Foil22 AWG
Foil18 AWG
Foil 18 AWG
Foil20 AWG
Foil18 AWG
HART
HART® - Cable Specifications
OverallFoil Shield
Device GroundGreen/Yellow
DataBlue
Brown
Device GroundGreen/Yellow
A
A
Ref.
A B
UL [CSA]
PLTC300V or CM
[CMG HLBCD]
8 Pairs2/22 AWG
HART
HART
HART
HART
C D
DataBlue
Brown
B
C
D
Cable that is twisted pair cable, screened as a pairas specified in HART® Field CommunicationProtocol Technical Overview
Type
H40
H40A
H120
H190
HM40
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588076
min
ifast®
♣♣♣♣ ♣eu
rofa
st®**
eurofast®**
Sock
et (F
emal
e)So
cket
(Fem
ale)
Pin
(Mal
e)Pi
n (M
ale)
RSV
WSV
RKV
WKV
RSCV
WSCV
RKCV
WKCV
RSV
RKV
WKV RSCVWSV
Pin (Male) Socket (Female) Pin (Male)
minifast® ♣♣♣♣♣
RSV H 4 - *M
RSV RSV
HART® - Cables and Cordsets
RKV RKV RKV WKV RKV RSCV
WKV WKV WKV RSCV
RSCV RSCV
WSV RSCV H40-1M
1 METER
× ×
H 4 - *M× ×
WSV H 4 - *M× × RKV H 4 - *M× × WKV H 4 - *M× × RSCV H 4 - *M× ×
RSV WSV H 4 - *M× × RSV RKV H 4 - *M× × RSV WKV H 4 - *M× × RSV RSCV H 4 - *M× ×
WSV WSV H 4 - *M× × WSV RKV H 4 - *M× × WSV WKV H 4 - *M× × WSV RSCV H 4 - *M× ×
H 4 - *M× × H 4 - *M× × H 4 - *M× ×
H 4 - *M× × H 4 - *M× ×
H 4 - *M× ×
× Indicates cable typeIndicates length in metersStandard cable onlyArmorfast® cable onlyFor nickel-plated brass coupling nut: RSV...to RSM...
RSCV...to RSC...
***♣♣♣♣♣
Bulk cable, see page 8 for standard lengths.
Example
H 4 -*M× ×
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588077
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
minifast® bulkheadeurofast® eurofast® bulkhead **
Pin (Male)Pin (Male)Pin (Male) Socket (Female) Socket (Female) Socket (Female)
WKCVRKCVWSCV RSFPV RKFPV FSFDV FKFDV
WSCV RKCV WKCV RSFPV RKFPV FSFDV FKFDV
RSV WSCV RSV RKCV RSV WKCV RSV RSFPV RSV RKFPV RSV FSFDV RSV FKFDV
WSV WSCV WSV RKCV WSV WKCV WSV RSFPV WSV RKFPV WSV FSFDV WSV FKFDV
RKV WSCV RKV RKCV RKV WKCV RKV RSFPV RKV RKFPV RKV FSFDV RKV FKFDV
WKV WSCV WKV RKCV WKV WKCV WKV RSFPV WKV RKFPV WKV FSFDV WKV FKFDV
RSCV FSFDV RSCV FKFDV
RKCV RKCV RKCV WKCV RKCV RSFPV RKCV RKFPV RKCV FSFDV RKCV FKFDV
WKCV WKCV WKCV RSFPV WKCV RKFPV WKCV FSFDV WKCV FKFDV
HART® - Cables and Cordsets
H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× ×
H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× ×
H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× ×
H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× ×
H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× ×
RSCV WSCV RSCV RKCV RSCV WKCV RSCV RSFPV RSCV RKFPV H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× ×
H 4 - *M× ×
H 4 - *M× ×
H 4 - *M× ×
H 4 - *M× ×
H 4 - *M× × H 4 - *M× ×
WSCV FSFDV WSCV FKFDVWSCV WSCV WSCV RKCV WSCV WKCV WSCV RSFPV WSCV RKFPV H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× ×
H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× ×
H 4 - *M× ×
H 4 - *M× ×
H 4 - *M× ×
H 4 - *M× ×
H 4 - *M× ×
H 4 - *M× ×
H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× × H 4 - *M× ×
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588078
minifast® Cordset and Receptacle Connector Dimensions and Pinouts
RSV-* RKV-*
WSV-* WKV-*
RSFPV-* RKFPV-* Mounting Installation
MALE FEMALE
1. Blue (-Voltage)2. Brown (+ Voltage)3. Bare (Shield Drain Wire)4. Green/Yellow (Ground)
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588079
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
RSCV-* RKCV-*
WSCV-* WKCV-*
eurofast® Cordset and Receptacle Connector Dimensions and Pinouts
Mounting InstallationFSFDV-* FKFDV-*
FEMALEMALE
1. Blue (-Voltage)2. Brown (+ Voltage)3. Bare (Shield Drain Wire)4. Green/Yellow (Ground)
4
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588080
mul
tifas
t®
Sock
et (F
emal
e)Pi
n (M
ale)
Pin (Male) Socket (Female)
multifast®
CSM H1 -*M
CSM CSM H1 -*M
CSWM H1 -*M CKM H1 -*M CKWM H1 -*M
CSM CSWM H1 -*M CSM CKM H1 -*M CSM CKWM H1 -*M
HART® - Cables and Cordsets
CSM CSWM CKM CKWM
CSM
CSWM
CKM
CKWM
CSWM CSWM H1 -*M CSWM CKM H1 -*M CSWM CKWM H1 -*M
CKM CKM H1 -*M CKM CKWM H1 -*M
CKWM CKWM H1 -*M
Coupling nuts shown are nickel-plated brass. Consult factory for availability of stainless steel.
1 METER
CSWM CKM H1 - 1M
×× ×× ××
××
××
×× ×× ××
×× ×× ××
×× ××
××
× Indicates cable typeIndicates length in meters*
Bulk cable, see page 8 for standard lengths.
Example
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588081
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
CSM...CKM... CSWM...CKWM...
multifast® Receptacle Connector Dimensions and Pinouts
Functional Wiring Diagramfor 19-Pin Cordset
Functional Wiring Diagramfor 12-Pin Cordset
12-pin 19-pin12-pin 19-pin
Male Female Male Female
V -V +J1
V -V +J2
V -V +J3
V -V +J4
Drain
V +V -
V +V -
V +V -
V +V -
Drain
J1
J2
J3
J4
J5
J6
J7
J8
Ground GroundDrain Drain
Drain Drain
Drain Drain
Drain Drain
V -V +
V -V +
V -V +
V -V +
Drain
V +V -
V +V -
V +V -
V +V -
DrainGround Ground
Drain
Drain Drain
Drain Drain
Drain Drain
V -V +
V -V +
V -V +
V -V +
V +V -
V +V -
V +V -
V +V -
Drain
Drain Drain
Drain Drain
Drain Drain
Drain
Drain
HART®NAMUR Color HART®NAMUR Color
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588082
HART® Junction Tee
Schematic/Connector
Description
Dimensions
The HART® junction tee provides a rugged connection to all of your fieldbusdevices. Mechanically rugged, the new overmolded design provides unparalledcorrosive resistance. It is also available with either multifast® connectors forpoint- to-point wiring, or minifast® connectors for multidrop installations.
JTBS-40H-CS1212-Pin Male
JTBS-70H-CS1919-Pin Male
JTBS-60HM-RS44-Pin Male
* change RS to RSV for stainless steel connectors change CS to CSV for stainless steel connectors (consult factory for availability)
P1
P1
J0-J4
J0-J7
Wiring 4-port Wiring 7-port Wiring Multidrop
HART Transmitter
NAMUR Sensor
P1, J0-J6
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588083
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
JTBS-40H-CSV12*
JTBS-40H-CS12
JTBS-70H-CSV19*
JTBS-70H-CS19
Num
ber o
f Por
ts
Con
nect
or S
ize
Ove
rmol
d M
ater
ial
Con
nect
or M
ater
ial
Shor
t Circ
uit P
rote
cted
4
4
7
7
stainless steel
nickel-plated brass
stainless steel
nickel-plated brass
mini
mini
mini
mini
polyurethane No
No
No
No
polyurethane
polyurethane
polyurethane
JTBS-40HM-RSV4
JTBS-40HM-RS4
JTBS-60HM-RSV4
JTBS-60HM-RS4
4
4
6
6
stainless steel
nickel-plated brass
stainless steel
nickel-plated brass
mini
mini
mini
mini
polyurethane No
No
No
No
polyurethane
polyurethane
polyurethane
Hom
e R
un C
onne
ctor
(P1)
12-pin multi
12-pin multi
19-pin multi
19-pin multi
4-pin mini
4-pin mini
4-pin mini
4-pin mini
* Consult factory for availability
(J0-
JX)
Part Number
4
Quick Selection Guide
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588084
eurofast® Multibox Aluminum Junctions (Bricks)
Brick for HART®; point-to-point with Home Run connector.♦ Aluminum enclosure♦ Nickel-plated brass connectorsDescription
Schematic/Connector
Dimensions
Wiring 4-port Wiring 8-port
VBM-40H-CS12 VBM-80H-CS19
* Consult factory for availability of stainless steel.
HART Transmitter
NAMUR Sensor
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588085
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
eurofast® Multibox Nylon Junctions (Bricks)
Brick for HART®; point-to-point with Home Run connector♦ Nylon enclosure♦ Nickel-plated brass connectorsDescription
Schematic/Connector
Dimensions
Wiring 4-port Wiring 8-port
4MB12-40H-CS12 8MB12-40H-CS19
*Consult factory for availability of stainless steel.
4
HART Transmitter
NAMUR Sensor
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588086
FSV H4 -*M / 14.5 FSV H4 -*M / M20
RSFV H4 -*M / M20
male minifast® female eurofast®
RSFV H4 -*M / 14.5
24.6 [0.97]
M12x1-6gM20x1.5-6g
9.5 [0.37]
28.5 [1.12]
M20x1.5-6g
1.023 [26.0]
1/2-14NPT
.512 [13.0]
M12x1 .984 [25.0]
1.162 [29.5]
7/8-16UNC
.493[12.5]
.295 [7.5]
1/2-14NPT7/8-16UNC
1. Blue (-Voltage)2. Brown (+ Voltage)3. N/C4. Green/Yellow (Ground)
1/2 - NPT
M20
eurofast® minifast®
FSV H4 -*M / 14.5 RSFV H4 -*M / 14.5
FSV H4 -*M / M20 RSFV H4 -*M / M20
Device Gland Receptacles - 3 wireSelection Guide
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588087
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Dimensions
Description
Conduit connectors for use with armorfast® cable O-Z Gedney JMC-50-71 1/2NPT
47.5 [1.87]
131.4 [1.87]
110.5 [4.35]
The conduit adapter attaches to a standard conduitbody for transition to minifast® or eurofast® connectors.
Conduit Bodies
♦ Gasket and mounting hardware included (8-32 x 1/2”)
4
Conduit Multidrop Adapter
1-po
rt2-
port
BCA 4HM-M223
BCA 4HM-M123
BCA 4HM-E223
BCA 4HM-E123
eurofast®minifast®
CROUSE - HINDS Hub Size = 3/4
Shape
C
LB
LL
LR
Style
Form 8Mark 9
Form 8Mark 9
Form 8Mark 9
Form 8Mark 9
Part Number
C28C29
LB28LB29
LL28LL29
LR28LR29
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588088
DimensionsPart Number Description
minifast® Multidrop
eurofast® Multidrop
RSV 2RKV HM4
RSV FKV RKV HM4
For nickel-plated brass coupling nuts:Change part number (RSV 2RKV ... RSM 2RKM ...)
HART® Multidrop Tees
DimensionsPart Number Description
RSCV 2RKCV H4
eurofast® Multidrop
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588089
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
SPTT1-AHM4 SPTTM13-AHM4
Pin Designation Color
1
2
3
4
V -
V +
Shield
Ground
Blue
Brown
Bare
Green/Yellow
Field Wireable multidrop® Tee
The Field Wireable Tee is a hybrid connection offering system-wide “plug-and-play” convenience.This allows an extremely rapid changeover to a connectorized network, often in less than 15minutes. The Field Wireable IP67 Tee features standardized minifast ® connectors for the dropconnection and field wireable terminals on the trunk connections. This provides the best of bothworlds, reliable connections on the short lengths and ease of installation planning on the long trunkruns.
Description
Specifications
Dimensions
Wire Table
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588090
minifast® to eurofast® Adapter
Dimensions
minifast® Male Gender Changer♦ female cordset to male receptacle
minifast® Female Gender Changer♦ male cordset to female receptacle
minifast® Elbow♦ right angle male to female connector
♦ minifast® male to eurofast® female connector
Part Number Description
Gender Changers and Elbow Connectors
Selection Guide
For nickel-plated brass coupling nuts:Change part number (RSV RSV...RSM RSM...)
RSV RSV H4
RKV RKV H4
WSV RKV H4
RSM H4-FK 4.5
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588091
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Bulkhead Feed-Thru Receptacles
RSFV RKF H4/22
FKV FSV H4/M12
For nickel-plated brass coupling nuts change part number:
For jam nuts or spare nuts order:LN-SS 1/2-14[10/BAG] or LN-SS12[10/BAG]
RSFV RKFV H4/22 to RSF RKF H4/22 or
FKV FSV H4/M12 to FKM FS H4/M12
panel mount
4
eurofast® Bulkhead Receptacle♦ straight male/female feed-thru .500
12.7
.1253.2
.0621.6
.87522.5
Panel Cutout
Panel Cutout
Dimensions
Dimensions
minifast® Bulkhead Receptacle♦ straight male/female feed-thru
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588092
RKFV H4 - *M RSFV H4 - *M
FKV H4 - *M FSV H4 - *M
female minifast® male eurofast®
1. Blue (-Voltage)2. Brown (+ Voltage)3. Bare (Shield Drain Wire)4. Green/Yellow (Ground)
Panel Mount Receptacles - minifast®, eurofast®
RKFV H4 - *M RSFV H4 - *M
FKV H4 - *M FSV H4 - *Meurofast®
minifast®
Selection Guide Female Male
eurofast®
minifast®
lead
sca
ble RKFV H40 - *M RSFV H40 - *M
FKV H40 - *M FSV H40 - *M
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588093
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
CKF.. or CSF..
4
Panel Mount Receptacles - multifast®
CSF H12
CSF H19
CKF H12
CKF H19
12-pin
Selection Guide Female Male
19-pin
Lea
dsCa
ble CSF H120
CSF H190
CKF H120
CKF H190
12-pin
19-pin
12-pin 19-pin12-pin 19-pin
Male Female Male Female
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588094
B 4149-0/9 BS 4149-0/9
BSV 4149-0/9BV 4149-0/9
Male Female
1. Blue (-Voltage)2. Brown (+ Voltage)3. Bare (Shield Drain Wire)4. Green/Yellow (Ground)
Field Wireable Connectors - minifast®Aluminum Stainless SteelSelection Guide
BV 4149-0/9
BSV 4149-0/9
B 4149-0/9
BS 4149-0/9
Female
Male
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588095
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
B8141-0 B8241-0
BS8141-0 BS8241-0
female eurofast® male eurofast®
* Housing Material PBT Coupling Nut Material - Female - nylon
Male - nickel-plated brass
1. Blue (-Voltage)2. Brown (+ Voltage)3. Bare (Shield Drain Wire)4. Green/Yellow (Ground)
4
B8141-0 B8241-0
BS8141-0 BS8241-0
Straight Right Angle
Male
Female
Field Wireable Connectors - eurofast®Selection Guide
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588096
CK.. CS..
12-pin 19-pin 12-pin 19-pin
Male Female
Female contact holder, female threads Male contact holder, female threads
Field Wireable Connectors - multifast®12-pin 19-pinSelection Guide
CKV 19-0
CSV 19-0
CK 12-0
CS 12-0
Female
Male
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588097
For HART® Systems
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Description
Dimensions
Closure caps are for unused ports on the junction box.
Closure Cap
RSMV BC
RKMV BC
♦ Stainless steel♦ IP67 rated
4
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588098
Installations
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-588099
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Most projects start with a rough definition to develop the capital scope and then progress to detailed development.Development of the capital scope is often expressed in terms of the number of segments, transmitters and tanks. Thecabling can be expressed in the same way. Each transmitter requires one device gland and one cordset. Each tankrequires one tee, one drop cordset and typically one brick. The Home Run or trunk cable can run in either conduit orcable tray, so either a field wireable tee or a conduit adapter is required at each tank. A terminating resistor is needed atthe beginning and end of the network. A simple bill of materials can be developed as follows:
Example: 4 segments, 50 transmitters, 10 tank process
Often, for estimating purposes an average length of cordset and segment length is assumed. In this example 6m (20 ft.)cordsets and four 75m (250 ft) segments are estimated.
The cost and time of coping with continuous changes during the engineering design phase can be very expensive.However, with this model the changes are limited to the length of the cordset and spool of bulk cable. Design changescan even wait until all the transmitters are mounted. Simply taking physical measurements is as valid as any other designmethod.
Plug and play connectorization has been standard practice in industries ranging from appliance manufacturers to indus-trial sensors for many years. These industries have found it necessary to compete in a business climate where speed andconsistency of connection is king. Connectorization is the perfect complement to fieldbus systems. The concepts andgoals are identical…reduced installation, reduced troubleshooting and easy expansion. The fieldbus system minimizespoint to point wiring which can be time consuming and difficult to troubleshoot. Connectorization takes that one stepfurther, almost completely eliminating troubleshooting. Of course unforeseen problems are difficult to measure duringthe initial planning stages. However, problems do happen resulting in real costs - delayed startups, scrapped product, etc.The plants that have implemented plug-and-play connectorization claim up to 75% reduction in start-up. These are realcost savings.
Cost Savings
The initial capital cost is the major factor in selecting a method of connecting devices. These costs include material andinstallation costs. The cost of incorporating plug-and-play connectivity will cost 10 to 60 percent less. Actual savingswill depend on the size and complexity of the installation.
In addition, other factors include reduced design cost, reduced maintenance cost, reduced troubleshooting cost andreduced expansion costs. Some of these cost savings are difficult to determine until the condition exists. However, thesecosts can quickly change from potential cost savings to real cost savings when the installation begins.
Product NumberDescription QuantityDevice Glands RSFV 49– 0.3M/14.5 Qty. 50Cordset RSV RKV 490 - 6M Qty. 60 (50 transmitters + 10 drops)Brick JTBS 49SC – M633 Qty. 10Field Wireable Tee SPT1-MT13 Qty. 10Terminating Resistor RSV 49 TR Qty. 8Bulk Cable CABLE, 490 - 300M Qty. 1
Design Cost Savings
5
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880100
The cost of cordsets and bricks will be equivalent or slightly lower compared to the cost of termination in enclosures.The plug-and-play junction bricks are IP67 rated (equivalent NEMA 4X). This mean they can be mounted indoors oroutdoors without any secondary enclosures. A NEMA 4X enclosure can cost anywhere from $75 for steel to $275 forstainless steel. After the design and installation time required to put mounting holes in the enclosure and installing cableglands, the cost can increase by another $40 to $60. A cage clamp style termination block costs $200 to $450 dependingon whether it has short circuit protection. The plug-and-play bricks cost only $295 and $445 depending on whether theyhave short circuit protection. A set of six cordsets costs only $264 (RSV RKV 490-1M).
The material cost comparison for a stainless steel installation is as follows:
Field Wiring Plug-and-Play
NEMA 4X Box (Hoffman® or equivalent) $ 275 Junction Tee (JTBS 49SC-M613) $445Cage Clamp Termination Block 450Installation of Block in Box 50Bulk Cable (6 Meters) 12 Cordsets (Six RSV RKV 490 - 1M - $44.00) 264Device Gland (1/2 NPT Fitting - $8) 48 Device Gland (RSFV 49 - 0.3M/14.5 - $30.30) 181
Total $ 820 Total $ 890
A junction brick system that is completely encapsulated for use indoors or outdoors is equivalent or 10% more expensivethan a termination block mounted in an enclosure. The real savings are in the installation.
The cost of installing a plug-and-play connector system can be 90% lower than terminating in cage clamps. The timerequired to make a plug-and-play connection is less than 30 seconds per connection. The time required to strip the jacket,prepare the conductors, feed the cable through a gland, insert the wires into the terminals and tighten the cable gland is 5to 10 minutes per connection. This is often complicated when the installation is in a physically demanding location. At alabor cost of $28.00 / hour per NECA labor units, this adds up fast. Terminating this many connections on just a 6 – portjunction brick means a difference of $33.00 as compared to $3.30. The real savings are often hidden since the wiringerrors are eliminated.
Field Wiring Plug-and-Play
Install 6 cables to brick (10 min. ea.) $28.00 Install 6 connectors to brick (1/2 min. ea) $1.40Install 6 cables to device (10 min. ea.) $28.00 Install 6 connectors to brick (1/2 min. ea) $1.40Termination check of system (20 min) 9.33 Termination check of system (n/a) -----
Total $65.33 Total $2.80
One of the most important features with plug-and-play connectors is that transmitters can be taken on and off the bus veryquickly – with little or no disruptions to operations and no disruptions to the bus. A device can be added to a junctionbrick spare port much more easily than any terminal strip. Any conceivable change required in the process can be madesimply by planning a couple of spare ports.
Maintenance Savings
Material Costs
Installation Savings
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880101
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Planning for plug-and-play can be second nature in a good installation. As with any process control, there are processesthat need to interact and processes that should stay independent. There are populations of activities and a material flow.The example below shows a layout of a chemical processing facility. The raw material kitchens are controlled on twoseparate segments and the main batch processing areas controlled on three segments. The diagram below shows theposition of the bricks in each process area.
Planning for Plug-and-Play
Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880102
Most smart devices use power from the network cable. Proper design should take this into consideration. The voltageneeded for fieldbus is 9-32 VDC. Most often the typical size for power is 24 VDC because of its popularity. Dependingon the length and type of the fieldbus cable there can be a voltage drop over the cable that can cause the level at the endto be below the 9V threshold. The amperage needed depends on the number of devices and the total current draw ofthose devices. The majority of smart devices will consume 10 to 25 mA of current each.
Fieldbus allows for up to 32 addressable devices per segment. However, most manufacturers of host systems recommendthat a segment have no more than 16 devices on it. The host cards do not have enough computing capabilities to handleall the different tags of data that a full 32 devices would generate.
See Figure 8 for a sample layout of how to compute the needed amperage for a system. On this segment there are 8smart fieldbus devices shown with their corresponding current consumption. Current consumption info should be listedon the device specification sheet or on the device label.
Figure 8 - Sample Layout
Power Considerations
The best way to do the current calculation is to do a Nodal Analysis. This type of analysis involves summing all thecurrent draws at each junction point and then sum the totals of those. It is easier to change the physical layout drawing toa nodal layout. See Figure 9 for the Nodal Drawing from the physical drawing Figure 8.
Figure 9 - Nodal Analysis Drawing
Starting from the right in this example, first sum the currents leaving Node 3.Node 3 = (4*25mA) + 20mA = 140mA.
This now becomes the amount of current necessary at I2, or departing Node 2 supplying Node 3. Then do the samecomputation on Node 2.
Node 2 = 25mA +140mA = 165mA.Now I1 is known to equal 165mA. Working back one more node to Node 1.
Node 1 = 25mA + 165mA = 190mA.
25 mA
25 mA
20 mA
25 mA
25 mA
20 mA25 mA25 mA
Node 1 Node 2 Node 3I1 I2I total
Current Consumption Calculation
D1 D2 D3
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880103
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Therefore, for this segment of 8 nodes a power supply capable of 200mA output is required. A good rule of thumb whendealing with industrial networks is to size the power supply with a 25% greater capacity. This allows some coverage fordevices that have a higher inrush current than what is labeled.
In a hazardous area the use of an Intrinsic Safety Barrier will limit the number of devices because of the current output,voltage ouput and the total amount of capacitance and inductance with which the barrier can properly operate.
The voltage drop in the system can be calculated using the same nodal analysis. The voltage drop depends on the lengthof the cable, designated as D1, etc. and the location of the current draw. In this example, a typical 18 AWG fieldbus cablewill be used with a resistance of 6.5 Ω / 1000 ft (0.021 Ω / M). In these calculations we will designate it as Rcable/m.Most fieldbus power systems supply 24 VDC.
This time we need to start at the left and calculate the voltage at Node 1:
Voltage @ Node 1 = 24 VDC – [D1 * Rcable/m] *Itotal
= 24 VDC – [ 15M * 0.021 Ω/M ] * 185 mA
= 23.94 VDC
In a short distance there was not a significant amount of voltage drop, only 0.06 VDC. However, as the distancesincrease the voltage drop becomes a factor. The voltage at Node 2:
Voltage @ Node 2 = Voltage @ Node 1 – [ D2 * Rcable/M ] * I1
= 23.94 VDC – [300M * 0.021 Ω / M] * 165 mA
= 22.90 VDC
Continuing with the last node, Node 3:
Voltage @ Node 3 = Voltage @ Node 2 – [ D3 * Rcable/M ] * I2
= 22.90 VDC – [ 300M * 0.021 Ω / M ] * 140 mA
= 22.02 VDC
So, the entire voltage drop across the system is roughly 2 VDC. All fieldbus devices should operate at a voltage from 9 –32 VDC. Therefore this system should work fine with plenty of margin.
Voltage Drop Calculation
Power Considerations (Continued)
5
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880104
The SPTT1 – A49 field wireable tee has conventional screw terminals inside of a NEMA 4X enclosure for both thetrunk and drop terminations. This allows the drop cable to be pulled through conduit down to a conduit body. The
cable can then be terminated into the screw terminals of theBCA 49–M223 conduit adapter for connection to either oneor two devices or to a brick.
The BCA 49–M223 can also be used to adapt from any conduit body to plug-and-play connectorization.
The two most common methods of installing the trunk cable are cable tray and conduit. Longer runs are typically moredifficult to estimate, so using bulk cable is standard practice. InterlinkBT™ offers several adapter products to break outof either cable tray or conduit.
The SPTTM1–A49 field wireable tee has conventional screw terminals inside of a NEMA 4X enclosure for the trunktermination and a minifast® port for the drop. Plug-and-play cordsets with either standard or armorfast® cable can beused to connect to either a single transmitter or a brick.
Installation of Trunk
47.5 [1.87]
131.4 [1.87]
110.5 [4.35] optional terminating resistor
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880105
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
InterlinkBT offers a device gland receptacle that mounts into the ½ NPT or M20 port of most transmitters. The devicegland has 2 or 3 wires to connect to the transmitter screw terminals. The other side is either a minifast® or eurofast®receptacle. The device gland is offered as an option by some transmitter manufactures. Otherwise it can be installed in
the field. The advantage of this connection is that theinstallation or replacement of a transmitter can be made veryquickly.
After the transition out of either cable tray or conduit the use of bricks is the best way to consolidate wiring. The brick is aparallel wired device that essentially acts as a multi-drop box. The new JTBS-49SC series and JBBS-49SC series not only consolidate wiring, but also offershort circuit protection.
Blue (-Voltage)Brown (+ Voltage)Green/Yellow (Ground)
Installation of Drops
Installation at the Device
The shield drain wire is not connected to the transmitter. Theshield should be terminated only at the control cabinet. Thisprevents the shield from grounding to a secondary groundwhich could produce ground loops.
5
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880106
A terminating resistor is required at both ends of the trunk. The trunk is the longest run of the segment. The purpose ofthe terminating resistor is to preventreflections at the end of the cable.
InterlinkBT offers both a two and three conductor cabling system. A twisted pair (blue and brown) are used to carry thesignal (V+ and V-). The third conductor is provided as a convenience ground for transmitters. If the distance betweenthe transmitter and the brick is relatively short, less than 6m (20 ft), several transmitters can be grounded at the brick.The ground stud should be connected to earth ground with a 12 awg or equivalent conductor. The device ground conduc-tor is broken at P1 (SEGMENT IN) so that the local ground of one brick is not tied to the local ground of another. Thiseliminates the potential of ground loopsin the system. The cables also have ascreen and drain wire. The drain wirepasses through each of the connectorsand the bricks not connected to anychassis grounds. The drain wire shouldbe terminated to an earth ground at asingle point, typically at the earthground for the control system.
Device Ground
Blue (V-) Brown (V+) Bare (Shield) Green (Device Ground)
Grounding
Terminating
The fieldbus signal is carried on the DCcarrier. A capacitor is also in theterminator to prevent the resistor fromabsorbing the energy on the trunk. TheRSV 49 TR can be installed into the lasttrunk connection of a brick.
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880107
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Nonincendive Equipment
Simply put, if you supply nonincendive equipment with its rated power and use it per its instructions, it will not produce heator sparks capable of igniting a hazardous atmosphere. It must not have normally arcing contacts and must not produce heatin excess of 80% of the ingnition temperature of the hazardous atmosphere. There is no fixed restriction on the amount ofpower as long as the preceding statement remains true. The energy level carried by the interconnecting wiring may farexceed the ignition curves.
Benefits:
♦ No NRTL approved safety barrier, special enclosure or supply of protective gas is required.♦ Quick disconnects are allowed with the use of a tool removable locking guard.
Nonincendive Circuits
The electrical energy in a nonincendive circuit is incapable of igniting a specific hazardous atmosphere under normalconditions. The concept is very similar to intrinsic safety, but lower safety factor and no faults considered in equipmentexaminations.
The energy level carried by the interconnecting wiring is below the ignition curves with a 10% margin. Therefore, anywiring method suitable for an equivalent non-hazardous location is acceptable.
Quick disconnects are also permitted because their disconnection does not result in an ignition-capable spark.
Benefits:
♦ No special wiring.♦ Quick disconnects allowed.
References: Bob Svacina and Brad Larson. Understanding Hazardous Area Sensing. Turck Inc., 4/01
Terminology
Properly classified Division 2 locations are often non-hazardous. They are essentially ‘buffer zones’ around Division 1locations in which an explosive atmosphere will never be present under normal conditions and only rarely as a result ofunforeseen equipment failures. If electrical faults in equipment occur fairly rarely, the risk of these events happeningsimultaneously is negligible. However, acceptable protection methods for Division 2 locations seem to be less widely under-stood than those for Division 1 locations, despite the lesser hazard. This is partly due to the fact that the somewhat cumber-some term ‘nonincendive’ is used to describe two very different Class 1, Division 2 protection methods:
♦ Nonincendive Equipment♦ Nonincendive Circuits
Nonincendive Installation for Division 2 Hazardous Locations
5
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880108
Non-Hazardous Location
Non-incendiveequipment connectionNon-incendivecircuit connection
Hazardous LocationClass 1, Division 2
The JTBS SC and JBBS SC series of bricks provide short circuit protection. In doing so they also limit the current to eachdrop or spur. The brick is classified as non-incendive equipment. In other words, under normal operating conditions itcannot create a spark that will cause ignition. The connection to the brick is the trunk connection, indicated as P1 and S0.These ports are not current limited and should not be disconnected unless the area is known to be non-hazardous. Inaddition, a tool removable locking guard must be installed on the quick disconnect connector.
Each of the drops, or spurs, is classified as a non-incendive circuit. It is current limited so that the energy in any sparkcaused by the separation of a connector cannot cause ignition. Any method suitable for wiring in ordinary locations can beused on the drop connections, indicated as S1,S2, S3...etc.
Typical Installation
Minifast® and eurofast® connectors are not explosion-proof. They can only be used in a Division 1 location in an intrinsi-cally safe system. The standard bricks, JTBS and JBBS series (not JTBS-49SC or JBBS-49SC) are considered as simpledevices. The bricks have no active circuitry and cannot store or generate more than 1.2 volts, 0.1 ampere, 25 milliwatts, or20 microjoules. These devices can be placed directly in the hazardous location without any certification. InterlinkBT offersa complete line of cordsets with blue cable (change part number from RSV RKV 490 -*M to RSV RKV 490B - *M). It isnot mandatory to use blue cable, but it is considered to be the best practice.
Class I, Division 1 Locations
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880109
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
There are basically four types of cable suitable for process bus installations. They are Type MC, Type TC, Type PLTCand Type ITC cable. Due to the similarities of the PLTC and ITC requirements cables will often carry a dual PLTC / ITCrating. Type ITC cable is for instrumentation and control circuits operating at less than 150 volts and less than 5 am-peres. Type PLTC cable is Power Limited Tray Cable, suitable for 300 volts. Process buses are typically 9-32 voltsystems that run at only 2 amps. In addition, ITC cable can be enclosed in a smooth metallic sheath, a continuouscorrugated metallic sheath, or interlocking tape armor applied over the nonmetallic sheath of an ITC cable.
The acronyms of each of the cables are expanded as follows:
ITC - instrumentation tray cablePLTC - power limited tray cableTC – tray cableMC – metal clad
Type ITC cable offers a great deal of flexibility in Class I, Division 2 installations. The basic installation guides requiremechanical protection and minimized open wiring lengths. This serves to protect the cable from potential damage. Someof the basic guidelines are noted in Article 727.6 of the NEC. The summary below may be used as a guideline. However,the local government inspection agency has final jurisdiction on the interpretation of the code.
Cable Types
Armorfast® ITC Cables may be used for open wiring. The cable must be supported and secured every 1.8 m (6 ft).
Standard ITC Cables may be used for open wiring without a metallic sheath or armor between cable tray and equip-ment in lengths not to exceed 15 m (50 ft), where the cable is supported and protected against physical damage usingmechanical protection, such as struts, angles or channels. The cable shall be supported and secured at intervals notexceeding 1.8 m (6 ft).
Installation of Fieldbus Cable in Cable Tray
Installation of Fieldbus Cable with Cables Rated Over 600V
Installation of Fieldbus Cable with Cables Rated 600V or LessFieldbus cable type PLTC is rated for 300 volts. Fieldbus cables may be mixed with other cables rated at either 300 or600 volts. Traditional instrumentation cable was often installed in a separate tray because of the volume of cables. Withfieldbus the number of cables is reduced dramatically, and as such may now be practical to install in the same tray asother general purpose cabling.
Fieldbus cables and branch circuit cables have been installed in the same cable trays without barriers with excellentperformance and reliability.
Fieldbus cable may be installed with cables rated over 600V if the cable is rated over 600 volts is Type MC (Metal Clad)or if the cables are separated with a fixed solid barrier of a material compatible with the cable tray.
5
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880110
3-wire fieldbus 490, 490B, HM40 59.5166
2-wire fieldbus 493, 483, 58.0297
3-wire armorfast® 492A, 482A, H40A 106.80851
Cable Examples Weight
Cable Tray Loads
( lbs. / 1000 ft.)
Typical Cable Tray Installations
RSV 2 RKV 49 with FOUNDATION™ Fieldbusminifast® cordsets.
SPTTM13-A49 to JBBS-49-M613 withFOUNDATION™ Fieldbus armor cable cordsets.
SPTTM13-A49 with FOUNDATION™ Fieldbusminifast® cordsets.
JBBS-49-M413 with FOUNDATION™ Fieldbusminifast® armor cable cordsets.
Although fieldbus wiring greatly reduces the loads in the cable tray, they must still be calculated. The table below indicatesthe weight per 1000 ft. of cable.
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880111
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
Proper Bend Radius for Fixed and Moving Applications
Eliminating Stress Points in Cable Dress
Fixed ApplicationsMinimum bend radius 5 x cable diameter
Moving ApplicationsMinimum bend radius 10 x cable diameter
Strain ReliefCorrect Incorrect
Proper management of cabling systems can mean the difference between a dependable and smooth operating installationand costly recurring down time. The suggestions outlined below illustrate some of the common sources of problems andprovide simple and effective solutions.
Providing sufficent bend radius will allow the cable to absorb the energy of bending over a greater portion of its length,increasing its effective working life. Small increases in the radius of the bend can produce subtantial increases in cablelife.
Installing cables to allow for adequate stress loops and freedom of motion increases the life of the cables. InterlinkBTcordsets incorporate molded strain reliefs that will assist in preventing stress.
Installation of Cable Types
5
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880112
Cable Bundling Techniques
Tying Cables with Cable Ties
Correct Incorrect
Correct Incorrect
When bundling several cables together, always keep the bundle loose enough to move within itself. Tightly tied bundlescreate both compression and tension stresses when the bundle is moved.
When tying cable with self locking ties, always leave the ties loose enough for the cables to slide freely under the tie.Over-tightening will create stress concentrations that can cause the conductors to fail prematurely. Never tighten the tieto the point where the cable jacket becomes deformed or pinched.
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880113
Photo Gallery
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880114
Photo Gallery
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880115
Photo Gallery
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880116
FOUNDATION™ Fieldbus - Index
BB 4149-0/9 ........................................................................40B8141-0 ............................................................................41B8241-0 ............................................................................41BRPC-49-M213 ................................................................36BS 4149-0/9 ..................................................................... 40BS8141-0 ..........................................................................41BS8241-0 ..........................................................................41BSV 4149-0/9 ...................................................................40BV 4149-0/9 .....................................................................40
CCable Types.........................................................................17Conduit Adapter ................................................................31Cordsets........................................................................ 18-21
FFKV 49 ..............................................................................39FKV FSV 49 / M12 ...........................................................38FSV 49 ...............................................................................39FSV 49-*M / 14.5 (3 wire) ................................................28FSV 49-*M / M20 (2 wire) ...............................................29
JJBBS-49-Exxx ..................................................................26JBBS-49-Mxxx .................................................................24JBBS-49SC-Exxx .............................................................27JBBS-49SC-Mxxx ............................................................25JTBS-49-Exxx ..................................................................23JTBS-49-Mxxx .................................................................23JTBS-49SC-Exxx .............................................................23JTBS-49SC-Mxxx ............................................................22
RRKFV 49 ...........................................................................39RKMV BC ........................................................................42RKV RKV 49 ....................................................................34RSCV 2RKCV 49 .............................................................32RSEV 49-TR .....................................................................30RSFV 49 ............................................................................39RSFV 49-*M / 14.5 (3 wire) .............................................28RSFV 49-*M / M20 (2 wire) ............................................29RSFV RKFV 49/22 ..........................................................38RSM 49-FK 4.5 ................................................................34RSMV BC ........................................................................42RSV 2RKV 49 ..................................................................32RSV 49-TR .......................................................................30RSV FKV RKV 49 ...........................................................32RSV RKV 49 SS ................................................................35RSV RSV 49 .....................................................................34
SSHLD, MINI (10/bag) .........................................37SPTTM13-A49 ....................................................33
WWSV RKV 49 ......................................................34
PROFIBUS®-PA
BB 4148-0/9 ............................................................69B8141-0 ................................................................70B8241-0 ................................................................70BS 4148-0/9 ..........................................................69BS8141-0 ..............................................................70BS8241-0 ..............................................................70BSV 4148-0/9 .......................................................69BV 4148-0/9 .........................................................69
CCable Types ..........................................................47Conduit Adapter ....................................................61Cordsets ...........................................................48-51
FFKV 48 -*M .........................................................68FKV FSV 48 / M12 ............................................. 67FSV 48 -*M ..........................................................68FSV 48-*M / 14.5 ............................................. ...58FSV 48-*M / M20 ................................................58
JJBBS-48-Exxx ...............................................56, 57JBBS-48-Mxxx ...............................................54, 55JTBS-48-Exxx ......................................................53JTBS-48-Mxxx .....................................................53JTBS-48SC-Exxx .................................................53JTBS-48SC-Mxxx ..........................................52, 53
R
RKFV 48 -*M .......................................................68RKMV BC ............................................................71RKV RKV 48 ........................................................64RSCS 2RKCS 48 ..................................................62RSEV 48-TR .........................................................59
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880117
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
F
FKV FSV H4 / M12 ............................................91FKV H4 -*M .......................................................92FSV H4 -*M ........................................................92FSV H4 -*M / 14.5 ..............................................86FSV H4 -*M / M20 .............................................86
J
JTBS-40H SC-CSV12 .........................................83JTBS-40H-CS12 .................................................82JTBS-40HM SC-RSV4 .......................................83JTBS-60HM-RS4 ................................................82JTBS-70H SC-CSV19 .........................................83JTBS-70H-CS19 .................................................82
R
RKFV H4 - *M ...................................................92RKMV BC ..........................................................97RKV RKV H4 ....................................................90RSCS 2RKCS H4 ...............................................88RSFV H4 -*M ....................................................92RSFV H4 -*M / 14.5 ..........................................86RSFV H4 -*M / M20 ..........................................86RSFV RKF H4 / 22 .............................................91RSM H4-FK 4.5 ..................................................90RSMV BC ...........................................................97RSV 2RKV HM4 ................................................88RSV FKV RKV HM4 .........................................88RSV RSV H4 ......................................................90
S
SPTTM13-AHM4 ...............................................89
V
VBM-40H-CS12 .................................................84VBM-80H-CS19 .................................................844MB12-40H-CS12 ..............................................858MB12-40H-CS19 ..............................................85
W
WSV RKV H4 ....................................................90
HART®
B
B 4149-0/9 ........................................................................94B8141-0 ............................................................................95B8241-0 ............................................................................95BS 4149-0/9 ......................................................................94BS8141-0 ..........................................................................95BS8241-0 ..........................................................................95BSV 4149-0/9 ...................................................................94BV 4149-0/9 .....................................................................94
C
Cable Types ......................................................................75CK 12-0 ............................................................................96CKFxx or CSFxx ..............................................................93CKM ...........................................................................80, 81CKV 19-0 .........................................................................96CKWM .......................................................................80, 81Conduit Multiplex Adapter ...............................................87Cordsets .......................................................................76-80CS 12-0 .............................................................................96CSM ............................................................................80, 81CSV 19-0 ..........................................................................96CSWM ........................................................................80, 81
RSEV 48-TR-Ex ................................................................60RSFV 48 -*M .....................................................................68RSFV 48-*M / 14.5 ............................................................58RSFV 48-*M / M20 ...........................................................58RSFV RKF 48 / 22 .............................................................67RSM 48-FK 4.5 .................................................................64RSMV BC ..........................................................................71RSV 2RKV 48 ...................................................................62RSV 48-TR ........................................................................59RSV 48-TR-Ex ..................................................................60RSV FKV RKV 48 ............................................................62RSV RKV 48 SS ................................................................65RSV RSV 48 ......................................................................64
SSHLD, MINI (10/bag) .......................................................66SPTT1-A48 .......................................................................63
WWSV RKV 48 ....................................................................64
6
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880118
Advanced I/O Module CatalogA thorough guide to DeviceNet™,PROFIBUS®-DP and IndustrialEthernet products.Request B9032.
Piconet® CatalogComplete guide to the miniature bus I/O product family.Request B9029.
AS-interface® CatalogThe most complete product offering ofAS-interface I/O stations, masters, gateways,cabling and accessories.Request B9040.
InterlinkBT™ 3000 Campus Drive Plymouth, MN 55441 Phone: (763) 694-2300 Fax: (763) 694-2399 Application Assistance: 1-888-546-5880119
Visit InterlinkBT on the Internet: http://www.interlinkbt.com
BL20 CDA complete electronic quide to the BL20IP20 Bus Terminal I/O system.Request B9037.
Busstop® CDContains complete Product Catalog,Cordset Wizard, Drawing Explorer,and Network Layout Tool.Request B9034.
BL20 Sales BrochureA sales overview of the BL20 I/OBus Terminal System.Request B9038.
WarrantyInterlinkBT, LLC (hereinafter “InterlinkBT”) warrants the Products covered by this WARRANTY AGREEMENT to be free from defects inmaterial and workmanship under normal and proper usage for 18 months from the date of shipment from InterlinkBT.
THE WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER REPRESENTATIONS MADE – BOTH EXPRESSED AND IMPLIED.THERE ARE NO WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE FOR PRODUCTS COV-ERED BY THESE TERMS AND CONDITIONS.
InterlinkBT warrants that the goods sold are as described, but no promise, description, affirmation of fact, sample model or representation,oral or written shall be part of an order, unless set forth in these terms and conditions, or are in writing and signed by an authorizedrepresentative of InterlinkBT. This warranty does not apply to any Product which has been subject to misuse, negligence, or accident – orto any Product which has been modified or repaired, improperly installed, altered, or disassembled – except according to InterlinkBT’swritten instructions.
This WARRANTY is subject to the following conditions:
1. This WARRANTY is limited to the electronic and mechanical performance only, as expressly detailed in the Product specifications andNOT to cosmetic performance.
2. This WARRANTY shall not apply to any cables attached to, or integrated with the Product. However, the 18 month warranty shall applyto cables sold separately by InterlinkBT.
3. This WARRANTY shall not apply to any products which are stored, or utilized, in harsh environmental or electrical conditions outsidewritten specifications.
4. The WARRANTY is applicable only to Products shipped from InterlinkBT subsequent to May 1, 1998.
Purchaser’s RemediesIf an InterlinkBT Distributor desires to make a WARRANTY Claim, the Distributor shall, if requested by InterlinkBT, ship the Product toInterlinkBT’s facility in Minneapolis, Minnesota, postage or freight prepaid. If the User desires to make a WARRANTY Claim, they shallnotify the authorized InterlinkBT Distributor from whom it was purchased or, if such Distributor is unknown, shall notify InterlinkBT. InterlinkBTshall, at its option, take either of the following two courses of action for any products which InterlinkBT determines are defective in materialsor workmanship.
1. Repair or replace the Product and ship the Product to the Original Purchaser or to the authorized InterlinkBT Distributor, postage orfreight prepaid; or
2. Repay to the Original Purchaser that price paid by the Original Purchaser.
PURCHASER’S REMEDIES SHALL BE LIMITED EXCLUSIVELY TO THE RIGHT OF REPLACEMENT, REPAIR OR REPAYMENT ASPROVIDED AND DOES NOT INCLUDE ANY LABOR COST OR REPLACEMENT AT ORIGINAL PURCHASER’S SITE. INTERLINKBTSHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF ANY WARRANTY, EXPRESSEDOR IMPLIED, APPLICABLE TO THE PRODUCT, INCLUDING WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM PROPERTYDAMAGE, PERSONAL INJURY OR BUSINESS INTERRUPTION.
Risk of LossDelivery of the equipment to a common carrier shall constitute delivery to the Purchaser and the risk of loss shall transfer at that time toPurchaser. Should delivery be delayed due to an act or omission on the part of the Purchaser, risk of loss shall transfer to the Purchaserupon notification by InterlinkBT that the order is complete and ready for shipment.
Consider Safety and Protection PrecautionsInterlinkBT takes great care to design and build reliable and dependable products, however, some products can fail eventually. You musttake precautions to design your equipment to prevent property damage and personal injury in the unlikely event of failure. As a matter ofpolicy, InterlinkBT does NOT recommend the installation of electronic controls as a sole device FOR THE PROTECTION OF PERSONNELin connection with power driven presses, brakes, shears and similar equipment and, therefore, the customer should build in redundancy ordual control using approved safety devices for these applications.
Governing LawThe sale and purchase of Products covered hereby and all terms and conditions hereof shall be governed by the law of the State ofMinnesota.
Product AvailabilityInterlinkBT makes every effort to stock most of these part numbers in reasonable quantities. InterlinkBT also makes no guarantee ofavailability of any product represented. Some part numbers are available on a special order basis only and may require longer lead times.Please consult with InterlinkBT when you need a committed delivery date.
Special Order ItemsCertain part numbers require minimum order quantities. As a general guideline, product not listed in this price list may be subject to 25piece minimum order quantity. If there is any question on availability or minimum order quantities, please contact InterlinkBT beforeordering.
Field ServicePlease contact InterlinkBT for details.