COVER, DRAWING LIST, ANDLOCATION MAPS
VICINITY MAPNOT TO SCALE
LOCATION MAPSCALE 1" = 2000'
MONTEREY DAM REMOVALCITY OF JANESVILLE, JANESVILLE, WI
FINAL DESIGN, October 24, 2017
LOCATION MAP - WISCONSINNOT TO SCALE
21
G
1
PROJECTLOCATION
ROCK RIVER
FLOW
MONTEREY DAM
AE
A
11
11
26
11
W COURT ST
MILWAUKEE ST
E RACINE ST
MONTEREYDAM
ROCK RIVER
CENTER AVE
W COURT ST
E RACINE ST
DATENO. REVISION DESCRIPTIONPROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
SHEET INDEX1 - COVER, DRAWING LIST, AND LOCATION MAPS2 - GENERAL NOTES AND ABBREVIATIONS3 - SITE PLAN4 - DEMOLITION PLAN5 - WETLAND PARK UPSTREAM PLAN6 - WETLAND PARK GRADING CROSS SECTIONS7 - PROPOSED CONDITIONS8 - PROPSOED CONDITIONS9 - TYPICAL SECTIONS10 - FABRIC DETAILS11 - FABRIC DETAILS12 - FES LIFTS CONSTRUCTION SEQUENCE13 - ACCESS, EROSION AND SEDIMENTATION CONTROL DETAILS
DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13
GENERAL PROJECT NOTES
1. THE UNDERGROUND UTILITY INFORMATION, AS SHOWN HERE, IS BASED, IN PART, UPON INFORMATION FURNISHED BY UTILITY COMPANIES AND THE LOCALMUNICIPALITY. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, IT'S ACCURACY AND COMPLETENESS CANNOT BE GUARANTEED OR CERTIFIED.
2. PRIOR TO EXCAVATION CALL TOLL FREE, DIGGERS HOTLINE, 1-800-242-8511. COST OF REPLACEMENT OR REPAIR OF EXISTING UTILITIES DAMAGED AS ARESULT OF THE CONTRACTOR'S OPERATION SHALL BE THE CONTRACTOR'S RESPONSIBILITY.
3. ELEVATIONS SHOWN ON THIS PLAN ARE REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM 1988, NAVD 88. COORDINATES ON THIS PLAN AREREFERENCED TO THE NORTH AMERICAN VERTICAL DATUM 1983(NAD83 WISCONSIN STATE PLANES, SOUTH ZONE, US FOOT).
4. PROJECT CONTROL: SEE CONTROL POINT TABLE ON SHEET 4 OF MONTEREY DAM REMOVAL & RIVER RESTORATION SET.
5. THE CONTRACTOR SHALL FIELD VERIFY THE FOLLOWING:· 5.1. ELEVATIONS OF THE BENCHMARKS PRIOR TO COMMENCING WORK,· 5.2. PAVEMENT & UTILITY ELEVATIONS WHERE MATCHING INTO EXISTING WORK,· 5.3. HORIZONTAL CONTROL BY REFERENCING SHOWN DIMENSIONS TO KNOWN PROPERTY LINES. NOTIFY THE ENGINEER OF ANY DISCREPANCIES IN EITHER
VERTICAL OR HORIZONTAL CONTROL PRIOR TO PROCEEDING WITH WORK.
6. CONTRACTOR SHALL PROTECT AND MAINTAIN BENCHMARKS AND SURVEY CONTROL POINTS FROM DISTURBANCE DURING CONSTRUCTION.
7. CONTRACTOR SHALL PROTECT EXISTING SITE IMPROVEMENTS TO REMAIN FROM DAMAGE DURING CONSTRUCTION. COST TO RESTORE DAMAGEDIMPROVEMENTS TO THEIR ORIGINAL CONDITION, AS ACCEPTABLE BY THE OWNER, WILL BE THE RESPONSIBILITY OF THE CONTRACTOR.
8. CONTRACTOR SHALL MINIMIZE INTERFERENCE WITH ADJOINING ROADS, STREETS, WALKS, AND OTHER ADJACENT OCCUPIED OR USED FACILITIES DURINGCONSTRUCTION OPERATIONS. DO NOT CLOSE OR OBSTRUCT STREETS, WALKS, DRIVEWAYS, OR OTHER ADJACENT OCCUPIED OR USED FACILITIES WITHOUTPERMISSION FROM OWNER AND AUTHORITIES HAVING JURISDICTION. PROVIDE ALTERNATE ROUTES AROUND CLOSED OR OBSTRUCTED TRAFFIC WAYS IFREQUIRED BY OWNER OR AUTHORITIES HAVING JURISDICTION.
UTILITY CONTACTS
AGENCY CONTACTS
ALWAYS CALL BEFORE YOU DIGCALL 811 OR (800) 242-8511
(262) 432-7910(877) 500-9592 EMERGENCY ONLY
GENERAL NOTES ANDABBREVIATIONS 2
DATENO. REVISION DESCRIPTIONPROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13
SM
SM
SM
SM
SM
SM
SM
SMSM
SMSM
SMSM
SMSM
SMSMSM
SMSM
SMSM
SMSM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
DATENO. REVISION DESCRIPTIONPROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
SCALE IN FEET
0 16080
SUGGESTED CONSTRUCTION SEQUENCE1. CONTRACTOR SHALL SUBMIT A DEWATERING AND DEMOLITION PLAN
AT LEAST TWO WEEKS PRIOR TO BEGINNING OF DAM REMOVAL WORK.DAM DEMOLITION MAY BE COMPLETED “IN THE WET” WITHOUTISOLATING THE DAM FROM THE FLOWING RIVER.
2. ACCESS TO THE DAM SHALL BE WITHIN THE RIVER. ACCESS TO THERIVER SHALL BE FROM THE NORTH SIDE OF THE RIVER.
3. CONTRACTOR MAY TEMPORARILY PLACE STONE AND/OR CULVERTS INTHE RIVER TO FACILITATE ACCESS TO THE DOWNSTREAM FACE OF THEDAM FOR THE PURPOSES OF DEMOLISHING THE DAM. ALL MATERIALPLACED IN THE RIVER TO FACILITATE ACCESS MUST BE REMOVED UPONCOMPLETION OF THE DAM REMOVAL.
4. PROTECT BRIDGE PIERS AS REQUIRED BY THE CITY AND WDOT. (MORETO BE INSERTED HERE FOLLOWING STRUCTURAL RECOMMENDATION)
5. BEGIN REMOVING THE DAM STARTING AT THE SOUTH SIDE TO ALLOWFOR EXIT FROM THE RIVER WITHOUT CROSSING THE MOSTCONCENTRATED FLOW. THE DAM MAY ONLY BE REMOVED AT A RATETHAT ALLOWS THE IMPOUNDMENT WATER SURFACE ELEVATION TODROP 6 INCHES PER DAY.
6. INSTALL RIPRAP WHERE CONCRETE WAS REMOVED ADJACENT TO THESOUTH BRIDGE ABUTMENT.
7. WHEN ALL FLOW IS GOING THROUGH THE NOTCH WHERE THE DAM ISREMOVED, INSTALL TEMPORARY DIVERSION BARRIER WHERE SHOWN.THE PARALLEL NORTH SPILLWAY OF THE DAM SHOULD BE LEFT IN PLACEWHILE THE TOE OF THE BANK IS CONSTRUCTED TO CONTROL SEDIMENT.THE RIGHT BANK RECONSTRUCTION AREA DOWNSTREAM OF THEBRIDGE MUST BE DEWATERED PRIOR TO CONSTRUCTION.
8. AFTER THE WATER SURFACE ELEVATION DROPS BELOW THE TOP OF THEGATES, SUCH THAT NO WATER IS FLOWING OVER THEM, REMOVEDDAM CONCRETE AND SOIL MAY BE DISPOSED WITHIN THE FILL AREAS.CONCRETE MUST BE BROKEN INTO PIECES NOT LARGER THAN 2 FTPRIOR TO REUSE AS FILL MATERIAL. ALL EXPOSED REBAR MUST BEREMOVED FROM THE CONCRETE PRIOR TO REUSE AS FILL MATERIAL.
9. REMOVE VINYL SHEET PILE WALL TO AT LEAST 2 FT BELOW PROPOSEDGRADE.
10. REMOVE GATE AND CULVERT STRUCTURES TO AT LEAST 2 FT BELOWPROPOSED GRADE. COMPLETE BANK TOE CONSTRUCTION AS SHOWNTO ELEVATION 755.
11. REMOVE TEMPORARY TURBIDITY CURTAIN.
12. REMOVE AND DISPOSE OF PARALLEL SECTION OF THE SPILLWAY.
13. BUILD FABRIC ENCAPSULATED SOIL LIFTS WHERE SHOWN.
14. PLACE TOPSOIL WHERE SHOWN, SEED AS DESCRIBED IN THESPECIFICATIONS, AND INSTALL FINAL SURFACE FABRIC.
15. RESTORE DISTURBED AREAS OUTSIDE OF THE GRADING LIMITS TOPRE-PROJECT CONDITIONS.
MONTEREY DAM TO BEREMOVED TO 2-FT BELOWSTREAM BED ELEVATION
CENTER AVE
SHEET 8 - PROPSOED CONDITIONS
EXISTING UTILITY POLETO BE RELOCATED
PROPOSED ACCESS
EXISTING GATE STRUCTURETO BE REMOVED
EXISTING CULVERT STRUCTURETO BE REMOVED TO 2 FTBELOW PROPOSED GRADE
WATER MAIN IS ATTACHED TO BRIDGE
EXISTING VINYL SHEET PILEWALL TO BE REMOVED TO 2 FT
BELOW PROPOSED GRADE
GRAVEL CONSTRUCTION ENTRANCE
PROPOSED STAGING AREA
EXISTING BRIDGE PIERS TO BE PROTECTEDDURING DAM DEMOLITION
LIMITS OF DISTURBANCE
SHEET 7 - PROPOSED CONDITIONS
PLAN LEGEND
EXISTING 1 FT CONTOUR
PROPOSED 1-FT CONTOUR
LIMITS OF DISTURBANCE
TEMPORARY ACCESS
PROPOSED STAGING AREA
GRAVEL CONSTRUCTION ENTRANCE
DAM TO BE REMOVED
EXISTING PROPERTY LINES
PROPOSED SILT FENCE - TBD
SANITARY MAINS
WATER MAINS
UTILITY POLE LOCATION APPROX.
TEMPORARY DIVERSION BARRIER
EXISTING RIPRAP TO BE REMOVED
PROPOSED RIPRAP
SM
WM
MONTEREY DAM TOBE REMOVED
TEMPORARY DIVERSIONBARRIER
AVOID DISTURBANCE OF TREES IDENTIFIEDBY OWNER'S REPRESENTATIVE IN THIS AREA
EXISTING RIPRAP TOBE REMOVED, TYP
SITE PLAN 3DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13
SM
SMSM
SMSM
SMSM
SMSM
SMSM
SMSMSM
SMSM
SMSM
SMSM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
SCALE IN FEET
0 12060
PLAN LEGEND
EXISTING 1 FT CONTOUR
LIMITS OF DISTURBANCE
TEMPORARY ACCESS
PROPOSED STAGING AREA
GRAVEL CONSTRUCTION ENTRANCE
DAM TO BE REMOVED
EXISTING PROPERTY LINES
PROPOSED SILT FENCE - TBD
SANITARY MAINS
WATER MAINS
UTILITY POLE LOCATION APPROX.
TEMPORARY DIVERSION BARRIER
EXISTING RIPRAP TO BE REMOVED
SM
WM
DEMOLITION PLAN 4DATENO. REVISION DESCRIPTION
PROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13
MONTEREY DAM TOBE REMOVED
REMOVE DAM TO 2 FT BELOWEXISTING STREAM GRADE
WATER MAIN
PROPOSED ACCESS
EXISTING UTILITY POLETO BE RELOCATED
TEMPORARY DEWATERINGBARRIER
LIMITS OF DISTURBANCE
EXISTING VINYL SHEET PILEWALL TO BE REMOVED TO 2 FT
BELOW PROPOSED GRADE
AVOID DISTURBANCE OF TREES IDENTIFIEDBY OWNER'S REPRESENTATIVE IN THIS AREA
GRAVEL CONSTRUCTIONENTRANCE
EXISTING RIPRAP TOBE REMOVED, TYP
BRIDGE ABUTMENTS TO BE PROTECTED DURING DEMOLITION
PROPOSEDSTAGING AREA
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
763
760
757
758
759
761
762
76075
7
758
759
761
756757758
748749752750751753754
746747748
755755
760
756757
758759761762763
755755
760
760
756
756
757
757
758
758
759
759
761
761
762
762
763
763
755
760
754754
756757
758759
761 762 763
765 764
764766
767
745
750
743744
746747
748748748749
751
752
753
745
745
750
755760
765
743 743
744
744
746
746 74
7 748 74
9 751 75
2753754756757758759
761762
763764
766767768769
748
778
775PLAN LEGEND
EXISTING 1 FT CONTOUR
PROPOSED 1 FT CONTOUR
LIMITS OF DISTURBANCE
TEMPORARY ACCESS
TEMPORARY STAGING AREA
GRAVEL CONSTRUCTION ENTRANCE
EXISTING PROPERTY LINES
WATER MAINS
UTILITY POLE LOCATION APPROX.
EXISTING SIDEWALK
PROPOSED ADA-COMPLIANTSIDEWALK
FABRIC ENCAPSULATED SOIL LIFTS
PROPOSED RIPRAP
WM
SCALE IN FEET
0 6030
ROCK RIVER
PLACE DAM REMNANTS IN EXISTINGRESERVOIR PRIOR TO EARTHEN FILL
EXISTING WATER MAINATTACHED TO BRIDGE
GRADE EXISTING BERM AND PONDED AREABETWEEN CULVERTS AND GATES
TEMPORARY ACCESS
EXISTING UTILITY POLETO BE RELOCATED
DAM IMPOUNDMENTFILL GRADING
TEMPORARYSTAGING AREA
BIKE PATH TO BERESTORED FOLLOWINGCONSTRUCTIONACTIVITIES
AVOID DISTURBANCE OF TREES IDENTIFIEDBY OWNER'S REPRESENTATIVE IN THIS AREA
GRAVEL CONSTRUCTIONENTRANCE 2
9
19
REPLACE EXISTING BENCH AFTERCONSTRUCTION ACTIVITIES
EXISTING BILLBOARD SIGN, ELECTRICALBOX, FIRE HYDRANT, AND BIKE PATHSIGNAGE TO REMAIN UNDISTURBED
REMOVE APPROX. 65' OFEXISTING CHAIN LINK FENCEPLACE PROPOSED PICNIC
TABLES WHERE DIRECTED BYOWNER'S REPRESENTATIVE
TIE PROPOSED RIPRAPINTO EXISTING RIPRAPAT BRIDGE
FENCE FROM THIS POINTEASTWARD TO REMAIN.FINISH WITH FENCEATTACHED TO END POST
SEE DETAIL ON SHEET 9 FOR APPROXIMATENUMBERS OF WOOD PIECES. LOCATIONS
SHOWN ARE APPROXIMATE AND DO NOTREFLECT ACTUAL FINAL POSITION
LOG JAMCONSTRUCTION
39
WETLAND PARK UPSTREAMPLAN 5
DATENO. REVISION DESCRIPTIONPROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13
56
66
76
86
BIKE PATH SIGNAGE ANDFIRE HYDRANT TO REMAINUNDISTURBED
740
750
760
770
740
750
760
770
0+00 1+00 1+82
750
760
770
750
760
770
0+00 1+00 2+00 2+18
740
750
760
770
740
750
760
770
0+00 1+00 2+00 2+14
STA:
0+5
1.9
ELEV
: 742
.7
STA:
0+6
7.2
ELEV
: 756
.0 STA:
1+2
5.4
ELEV
: 765
.0
STA:
2+0
9.3
ELEV
: 764
.2
STA:
0+5
6.5
ELEV
: 761
.0
STA:
0+2
4.6
ELEV
: 758
.0
STA:
0+0
1.9
ELEV
: 755
.4
STA:
0+1
4.5
ELEV
: 756
.0
STA:
0+6
9.0
ELEV
: 761
.0
STA:
1+5
8.0
ELEV
: 762
.6
STA:
2+0
2.4
ELEV
: 763
.7
750
760
770
750
760
770
0+00 1+00 1+30
STA:
0+1
9.0
ELEV
: 756
.0
STA:
0+6
5.1
ELEV
: 759
.4
STA:
1+1
4.3
ELEV
: 757
.0
STA:
0+4
8.8
ELEV
: 758
.5
STA:
0+9
4.1
ELEV
: 759
.0
STA:
0+7
9.0
ELEV
: 759
.7ST
A: 0
+80.
1EL
EV: 7
60.0
SCALE: 1" = 20'
SCAL
E: 1
" = 2
0'
1x VERTICAL EXAGGERATION
LEGEND
EXISTING GRADE
PROPOSED GRADE
WETLAND PARK GRADINGCROSS SECTIONS 6
DATENO. REVISION DESCRIPTIONPROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13
55
CONSTRUCTION CROSS SECTION
65
CONSTRUCTION CROSS SECTION
75
CONSTRUCTION CROSS SECTION
85
CONSTRUCTION CROSS SECTION
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
756757
758
748749752
750751753754
746747748
745
750
743744
746747
748748748749
751
752
753
745
745
750
755
760
765
743
743
744
744
746
746 74
7 748 74
9 751 75
2753754
756757758759
761762
763
764
766767768769
748
749
748
SCALE IN FEET
0 4020
PLAN LEGEND
DAM IMPOUNDMENT FILL GRADING19
TIE PROPOSED BANK TREATMENTS INTO EXISTINGBANK PROTECTION
FES LIFTS - SEE SHEET 10
BRIDGE ABUTMENT TO BEPROTECTED DURING DEMOLITION
LOG JAMCONSTRUCTION
39
ROCK RIVER
EXISTING 1-FT CONTOUR
PROPOSED 1-FT CONTOUR
LIMITS OF DISTURBANCE
EXISTING PROPERTY LINES
WATER MAINS
BIKE PATH
FABRIC ENCAPSULATED SOIL LIFTS
TEMPORARY DIVERSION BARRIER
WM
PROPOSED CONDITIONS 7DATENO. REVISION DESCRIPTION
PROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13
SM
SM
SM
SM
SM
SM
SM
SM
SM
SM
SM
SMSM
SMSM
WM
WM
WMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWM
SCALE IN FEET
0 4020
PLAN LEGEND
EXISTING 1-FT CONTOUR
LIMITS OF DISTURBANCE
EXISTING PROPERTY LINES
WATER MAINS
BIKE PATH
FABRIC ENCAPSULATED SOIL LIFTS
TEMPORARY DIVERSION BARRIER
WM
SANITARYMAINS
BRIDGE ABUTMENTS TO BEPROTECTED DURING DAMDEMOLITION
REPLACE REMOVED CONCRETE WITHRIPRAP ALONG BRIDGE ABUTMENT
WATERMAINS
TEMPORARY DIVERSION BARRIER
PROPSOED CONDITIONS 8DATENO. REVISION DESCRIPTION
PROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13
TYPICAL SECTIONIMPOUNDMENT FILL GRADINGNOT TO SCALE
1TYP
ELEV. 746
ELEV. 755
ELEV. 758.5
21
TYPICAL SECTIONGRADING EXISTING BERM AND PONDEDAREA BETWEEN CULVERTS AND GATESNOT TO SCALE
2TYP
ELEV. 756
6 MAX.1
10 MAX.1
2 FT
4 FT
RIPRAP
FILTER FABRIC
COMPACTED BORROW MIXED WITH REUSED CONCRETE PIECESFROM DAM DEMOLITION. USED CONCRETE SHALL BE BROKENINTO PIECES NO LARGER THAN 2 FT IN MEDIAN LENGTH ANDMUST BE BURIED WITH A MINIMUM OF 3 FEET OF COVER. NOCONCRETE SHALL BE PLACED WITHIN 20 FEET OF THESTREAMBANK
6 INCHES OF TOPSOILFES LIFTS
EXISTING GRADE
PROPOSED GRADE
SURFACE FABRIC
COMPACTED BORROW MIXEDWITH REUSED CONCRETE PIECESFROM DAM DEMOLITION
ELEV. 758.5. TRANSITION HEREFROM 6:1 TO 10:1 MAX. TYP.
6 INCHES OF TOPSOIL
TERMINATION TRENCH 511
TERMINATION TRENCH 511
TERMINATION TRENCH 511
TERMINATION TRENCH511
TYPICAL LOW WATER LEVEL
BOLTED OR CABLE CONNECTIONS ASSITE CONDITIONS DICTATEPACK SLASH
BETWEEN LOGLAYERS
EMBED 2/3 LOGLENGTH (MIN.)
SALVAGEDFILL
SET LOGS PARALLEL TOCHANNEL AT ORBEHIND BANK TOP
TYPICAL HIGH WATER LEVEL
VOIDS BETWEEN LOGS SHALL BE FILLED WITH AWELL GRADED COBBLE/ GRAVEL MIXTURE
LOG PILE - EMBED 10 FT (MIN.)BENEATH SUBGRADE
TYPICAL SECTIONLOG JAM CONSTRUCTIONNOT TO SCALE
3TYP
FES LIFTS
6 INCHES OF TOPSOIL
TYPICAL SECTIONS 9DATENO. REVISION DESCRIPTION
PROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13
LEG WIDTH0.6" TAPEREDTO POINT
STAPLETHICKNESS0.4"
STREAM BED
3 FT MIN. OVERLAP
DOWNSTREAM FABRICLAYER LAPS UNDER
UPSTREAMFABRIC LAYERLAPS OVER
2 X 4 STUD CUTTO 18" LONG
FINISHEDSTAKES
GENERAL NOTES ON SECURING COIR FABRIC
1. SECURE THE OUTER FABRIC (WOVEN, WHERE APPLICABLE), WITH AWOODEN STAKE THROUGH THE FABRIC ON 3 FT CENTERS.
NOTE: HOLES FOR STAKES SHALL NOT BE PRECUT. STRANDS SHALL NOTBE CUT WHEN DRIVING IN STAKES. BROKEN STAKES WILL BE REPLACEDAT THE CONTRACTOR'S EXPENSE. DRIVE STAKES SO THAT 2" TO 3" OFTHE TOP OF THE STAKE IS LEFT EXPOSED.
2. OUTER FABRIC ENDS SHALL BE JOINED BY LAPPING THE UPSTREAMPIECE OF FABRIC OVER THE DOWNSTREAM PIECE. OVERLAPS SHALL BEA MINIMUM OF 3 FT, INNER FABRIC ENDS SHALL BE BUTTEDTOGETHER, NOT OVERLAPPED.
3 FT MIN
NOT TO SCALETYP1 TYPICAL DETAIL - FES LIFT
FLOW
PLAN VIEW
NOT TO SCALETYP2 FABRIC OVERLAP
FLOW
SECTION VIEW
NOT TO SCALETYP4 WOODEN STAKES & STAPLES
NOT TO SCALETYP3 FES LIFT FABRIC LAYERING
NOT TO SCALETYP5 TYPICAL DETAIL - FABRIC AND STAKES
3' OVERLAPSTAKE 6" FROM
OUTWARD EDGEOF FABRIC
2.5'
3'WOODENSTAKE
STAKES THOUGH BOTHFABRIC LAYERS
INNER FABRIC SHALLOVERLAP 1 FT
WOVEN (OUTER)COIR FABRIC
NON-WOVEN (INNER)COIR FABRIC
NATIVESEED MIXFILL OR
NATIVE SOIL
WOODEN STAKESON 3' CENTERS
CONTINUE SOIL SURFACE
FABRIC TREATMENT AND
KEY INTO TRENCH FROM
FES LIFT ON OPPOSITE SIDE
EXISTING MATERIAL
2x4 x 18" WOODEN STAKE
SALVAGED FINE GRAINEDEXCAVATED MATERIAL
NON-WOVEN (INNER) COIR FABRIC
ROCK TOEPROTECTION FABRIC ENCAPSULATED
SOIL (FES) LIFT
DOWNSTREAMEDGE OF FABRIC
KEY TRENCH
SOIL SURFACE FABRIC TREATMENTNON-WOVEN (INNER) COIR FABRIC
INNER FABRIC
OUTER FABRIC
DOWNSTREAMFABRIC
UPSTREAM FABRIC (TOPLAYER OF OVERLAP)
STAKES THROUGH BOTHLAYERS AT OVERLAP
-3
8 FT
WOVEN (OUTER)COIR FABRIC
FABRIC DETAILS 10DATENO. REVISION DESCRIPTION
PROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13
DOWNSTREAM FABRIC LAYER LAPS UNDER
TYPICAL DETAILFABRIC JOINING
3 F
T M
IN.
OV
ER
LA
P
FLOW
NOT TO SCALE
B B'
FLOW
SECTION A - A'FABRIC FOLDNOT TO SCALE
FLOW
1 FT MIN
2 FT
UP
ST
RE
AM
FA
BR
IC L
AP
S O
VE
R
DO
W
NS
TR
EA
M
FA
BR
IC L
AP
S U
ND
ER
ISOMETRIC DETAILFABRIC JOINING
NOT TO SCALE
UPSTREAM FABRIC
LAYER LAPS OVER BY 3 FT MIN.
45°
TYPICAL DETAILFOLDING OF OUTER FABRICNOT TO SCALE
FLOW
A'
A
ALL FABRIC FORMS WILL BELAPPED IN AN UPSTREAM TODOWNSTREAM DIRECTION
MAX. ANGLE 15°
2 FT
1 FT MIN.
2 FT MIN.
KEY TRENCH DETAILTERMINATION TRENCHNOT TO SCALE
1 FT MIN.
2 FT MIN.
KEY TRENCH DETAILTRANSITION TRENCHNOT TO SCALE
3/4" PLYWOOD
8 FT
1.5 F
T M
AX
.
2
F
T
90°
1
F
T
2 FT
TYPICAL DETAILSSTREAM BANK CONSTRUCTION FORM - FES LIFTNOT TO SCALE
90°
1 - 1.5 F
T
3 FT
1.
2. 3. 4. 5. 6.
1 - 1.5 FT
SUGGESTED CONSTRUCTION SEQUENCEFES LIFT - BOX ENDSNOT TO SCALE
3 FT
STAKES THROUGHBOTTOM FABRICLAYERSTAKES 3 FT OC IN
STAGGERED ROWS
CONSTRUCTIONFORM
STAKES THROUGH BOTHFABRIC LAYERS
KEY TRENCH
CONSTRUCTIONFORM
STAKES 3 FT OC INSTAGGERED ROWS
FABRIC FOLD STAKES
STAPLES 18 IN OC INSTAGGERED ROWS
STAPLES 18 IN OC INSTAGGERED ROWS
FILL KEY TRENCH WITHTOPSOIL AND COMPACTOVER COIR FABRIC
STAKE FABRIC TO BOTTOMOF KEY TRENCH EVERY 3L.FT
EDGE OF FABRIC 4" MINFROM STAKE
STAKE FABRIC TO BOTTOMOF KEY TRENCH EVERY 3L.FT
EDGE OF FABRIC 4" MINFROM STAKE
FILL KEY TRENCH WITHTOPSOIL AND COMPACTOVER COIR FABRIC
WOVEN COIR FABRIC WRAP
1/4" LAG BOLT WITHNUT AND WASHER(TYPICAL) 1 " SQUARE STEEL
TUBING
UPRIGHT
1/4" X 2" STRAP STEELLEGS
RECTANGULAR FRAME
1 " SQUARE STEELTUBING
1/4" LAG BOLT WITHNUT AND WASHER(TYPICAL)
WELDED JOINTS(TYPICAL)
3/4" PLYWOOD BOLTED TOSTEEL FRAME
1/4" X 2" STRAP STEELLEG
EDGE OF EXCAVATIONCUT
EXISTING STREAMBANKOR ADJACENTTREATMENT
WHERE PRESENT, EMBED FABRICSINSTALLED ON ADJACENT SLOPEBEHIND FES LIFTS
FES LIFT
EXCAVATION LIMIT
BOX END SEQUENCEDETAIL
REMOVE SHADEDPORTION
NOTE: FES LIFT INNER FABRIC SHOULDBE INSTALLED WITHIN BOTH VERTICAL
FACES OF THE BOX END
1TYP
2TYP
7TYP
3TYP
5TYP
4TYP
6TYP
FABRIC DETAILS 11DATENO. REVISION DESCRIPTION
PROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13
GENERAL INSTRUCTIONS FOR FABRIC ENCAPSULATED LIFTS
1. BANKS MAY BE CONSTRUCTED IN EITHER AN UPSTREAM OR DOWNSTREAM DIRECTION, AS LONG AS THEFABRIC IS OVERLAPPED IN THE PROPER DIRECTION.
2. PLACE A SERIES OF THREE OR MORE FORMS ON THE GROUND SO THAT THE FORMS FOLLOW THE PROPOSEDSTREAM BANK ALIGNMENT. BUTT THE ENDS OF THE FORMS TIGHTLY TOGETHER.
3. UNROLL THE OUTER FABRIC PARALLEL TO THE LONG AXIS OF THE CHANNEL AND POSITION IT SO THAT 3FEET EXTENDS FOR EMBEDMENT ON THE BANK SIDE OF THE FORMS (FIG B), AND A MINIMUM 3 FEETEXTENDS LENGTHWISE BEYOND THE LAST FORM FOR OVERLAP. DRAPE THE REMAINDER OF THE FABRICOVER THE TOP OF THE FORMS ON THE STREAM SIDE (FIG B).
4. UNROLL THE INNER FABRIC OVER THE TOP OF THE WOVEN COIR FABRIC (FIG B) AND POSITION IT SO THATAT LEAST 1 FOOT OF THE INNER FABRIC EXTENDS AS AN EMBEDMENT LENGTH ON THE BANK SIDE OF THEFORMS (FIG C). DRAPE THE REMAINDER OF THE FABRIC OVER THE TOP OF THE FORMS ON THE STREAM SIDEAND ALIGN THE LONG EDGES OF THE FABRICS. STRETCH AND PULL THE FABRIC LAYERS TO REMOVEWRINKLES.
5. APPLY NATIVE SEED MIX TO INNER FABRIC ALONG VERTICAL EDGE OF LIFT (FIG C). PLACE SPECIFIED FILLOVER THE FABRIC ON THE BANK SIDE OF THE FORMS. LEVEL THE FILL AND COMPACT TO 85-90 PERCENTRELATIVE COMPACTION (FIG C).
6. APPLY NATIVE SEED MIX TO TOP OF FILL FROM THE FRONT OF THE LIFT TO 3 FT BACK FROM FRONT OF THELIFT (FIG C).
7. FOLD THE LOOSE ENDS OF THE TWO COIR FABRIC LAYERS BACK OVER THE COMPACTED FILL MATERIAL ANDSTRETCH TIGHTLY TO REMOVE WRINKLES (FIG D). SECURE WITH WOODEN STAKES 1 PER 3 L.F. ALONG THEBACK EDGE AND INTO UNDISTURBED SOIL.
8. REMOVE THE FORMS FROM THE FRONT OF THE COMPLETED LIFTS (FIG. 2). LEAVE THE LAST FORM IN PLACEAT THE END OF THE NEWLY CONSTRUCTED LIFT (FIG. 2).
9. WHERE THE TOP OF THE LIFT MEETS THE GROUND SURFACE, EXCAVATE A KEY TRENCH 1.5 FEET WIDE AND 1FOOT DEEP ALONG THE EDGE OF THE OUTER FABRIC LAYER, PARALLEL TO THE FORMS. SEED ENTIRE AREAOF TOP LIFT. SECURE FABRIC IN THE KEY TRENCH WITH WOODEN STAKES, 3 FT O.C.
10. BACKFILL THE KEY TRENCH WITH TOPSOIL AND CONTINUE TOAPPLY TOPSOIL TO SMOOTHLY MERGE WITH EXISTING CONTOURS.APPLY NATIVE SEED MIX TO KEY TRENCH AREA.
11. SUPPLEMENT LIFT STAKING WITH ADDITIONAL WOODEN STAPLESON 18" CENTERS EXCEPT WHERE WOODEN STAKES HAVEALREADY BEEN PLACED. FABRIC SHOULD BE TIGHT WITH NO LOOSEAREAS. LOOSE AREAS SHALL BE SECURED WITH ADDITIONAL STAPLES.
SUGGESTED SEQUENCE FOR PLACEMENT OF FORMS
PROFILE VIEW LOOKING INTO BANK
FIG 1. PLACE A ROW OF CONSTRUCTION FORMS ALONG DESIRED CHANNELALIGNMENT FOR FIRST FES LIFT.
FIG 2. CONSTRUCT FES LIFTS ALONG LENGTH OF FIRST SET OF FORMS ANDTHEN BEGIN PLACEMENT OF FORMS AND CONSTRUCTION OF SECOND LIFT.
FIG 3. STAGGER FABRIC OVERLAPS A MINIMUM OF 15 FT BETWEENLIFTS.
COMPLETED LENGTH OF FES LIFT
COMPLETED LENGTH OF FES LIFT
COMPLETED LENGTH OF FES LIFT 15 FT STAGGERS BETWEENCONSTRUCTION FORMS
3 FT EMBEDMENT
1 FT NON-WOVEN FABRIC
APPLY SEED TO PORTION OF SOIL THATWILL NOT BE COVERED BY THE NEXT LIFT
APPLY SEED TO EXPOSED VERTICALAND HORIZONTAL AREAS OF LIFT
FIG B.
FIG D.
FIG H.
FIG A.
FIG F.
FIG G.
FIG C.
FIG E.
BANK SIDE STREAM SIDE
CONSTRUCTION FORMSEE DETAIL 9/11
WOVEN COIR (OUTER FABRIC)
NON-WOVEN COIR (INNERFABRIC)
STAKE THROUGH BOTHLAYERS 6" BACK FROM FRONT
EDGE
EXISTING GROUND
APPLY SEED TO FABRICFACE
FILL WITH TOPSOIL
FOLD BOTH INNER AND OUTERFABRIC OVER SOIL
PLACE SECOND CONSTRUCTION FORM SO ASTO ACHIEVE REQUIRED FINAL SLOPE
FILL WITHTOPSOIL
FOLD BOTH INNER AND OUTER FABRICOVER SOIL
STAKE FABRICS IN PLACE ON 3 FTCENTERS. SEE FABRIC STAKING ANDTRENCHING SHEET 11
STAKE OUTER FABRIC IN TERMINATIONTRENCH. SEE FABRIC STAKING ANDTRENCHING SHEET 11
FLATTEN STREAM SIDE OF LIFT TO 45° FOLLOWINGINSTALLATION
REMOVE CONSTRUCTIONFORM PRIOR TO FLATTENINGLIFT TO 45°
PREPARE LEVELSUB-GRADE
PLACE FIRST STAKE IMMEDIATELY INFRONT OF NEXT LIFT, OR 2' (IF 2:1)FROM LIFT TOE IF THIS IS TOP LIFT
PLACE STAPLES ON 18" CENTERS. SEEFABRIC STAKING AND TRENCHING
SHEET 11
APPLY SEED TO VERTICAL FACE OFFABRIC PRIOR TO FILLING WITH SOIL
APPLY SEED TO VERTICAL FACE OFFABRIC PRIOR TO FILLING WITH SOIL
FES LIFTS CONSTRUCTIONSEQUENCE 12
DATENO. REVISION DESCRIPTIONPROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13
1.THE SILT FENCE FABRIC SHALL BE PURCHASED IN A CONTINUOUS ROLL CUT TO THE
LENGTH OF THE BARRIER TO AVOID USE OF JOINTS. WHEN JOINTS ARE NECESSARY,
FILTER CLOTH SHALL BE SPLICED TOGETHER ONLY AT A SUPPORT POST, WITH A MINIMUM
6 INCH OVERLAP, AND BOTH ENDS SECURELY FASTENED TO THE POST. ALTERNATIVELY,
OVERLAP AND INTERLOCK TWO POSTS WITH ATTACHED FABRIC AS APPROVED BY THE
OWNER'S REPRESENTATIVE.
2.THE SILT FENCE IS TO BE INSTALLED AT LOCATIONS SHOWN IN THESE DRAWINGS
ALONG THE DOWNHILL PERIMETER OF DISTURBED AREAS. THE FENCE POST SHALL BE
SPACED A MAXIMUM OF 6 FEET APART AND DRIVEN SECURELY INTO THE GROUND A
MINIMUM OF 24 INCHES APART.
SILT FENCE NOTES
3. THE SILT FENCE FABRIC SHALL HAVE A MINIMUM VERTICAL BURIAL OF 6 INCHES. ALL
EXCAVATED MATERIAL FROM SILT FENCE INSTALLATION SHALL BE BACK-FILLED AND
COMPACTED ALONG THE ENTIRE DISTURBED AREA.
4. STANDARD OR HEAVY DUTY SILT FENCE SHALL HAVE MANUFACTURED STITCHED
LOOPS FOR 2 INCHES X 2 INCHES POST INSTALLATION.
5. SILT FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE,
BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY PROTECTED AND
STABILIZED, OR AS DIRECTED BY THE OWNER'S REPRESENTATIVE.
PLAN VIEW
NOT TO SCALE
SIDE VIEW
NOT TO SCALE
FRONT VIEW
NOT TO SCALE
5 FT VEGETATED BUFFER
TOP OF BANK
4 FT
6 IN
2.5 FT
6FT MIN. SPACING
4 FT
2.5 FT
1.5 FT
6 IN
ANGLE BOTH ENDS OF SILT FENCE TO ASSURESOIL IS TRAPPED
INTERLOCK 2"X2"POSTS AND ATTACH
SILT FENCE FABRIC
USE STITCHED LOOPSOVER 2"X2" POSTS
SILT FENCE FABRIC MATERIAL36" WIDE ROLLS
20 FT MIN. WIDTH
50 FT MIN. LENGTH
WHEEL WASH AREASILT FENCE
RAMP - FULL WIDTHOF ENTRY
STD. CURB
SUBGRADE STABILIZATIONGEO-TEXTILE
GRAVEL CONSTRUCTIONENTRANCE MIN 8 IN. DEPTH
COMPACTED AGGREGATEBASE
STD. CURB
GAP FOR DRAINAGE
WOODEN RAMP(2"X4", 2"X8", 2"X12")
PAVED STREET
TYPICAL DETAILSILT FENCENOT TO SCALE
1TYP
TYPICAL DETAILGRAVEL CONSTRUCTION ENTRANCENOT TO SCALE
2TYP
ACCESS, EROSION ANDSEDIMENTATION CONTROL
DETAILS13
DATENO. REVISION DESCRIPTIONPROJECT
CHECKED
APPROVED
DRAWN
DATE
DESIGNED
SHEET
OF
301 South Livingston Street, Suite 200Madison, WI 53703
608.441.0342www.interfluve.com
DF, CP, BL
BC
BW
10/24/17
BC, MM
15-04-13 CITY OF JANESVILLEJANESVILLE, WI
MONTEREY DAM REMOVAL13