Strip Gen3 102 mm 375 lm LV3
Datasheet
Fortimo LED Strip Gen3Fortimo LED Strip systems are ideal for use in designer or miniaturized, slim linear luminaires for architectural applications, which were not previously possible with fluorescent lighting or Fortimo LED Line.
Key features and benefits• State-of-the-art LED module efficiency of up to 165 lm/W• Long life-time: >50,000 hours• High color rendering (CRI >80 and >90)• Excellent color consistency of 3 SDCM• Variety of color temperatures (3000 K, 4000 K and 5000 K)• Two lumen packages: 650 lm and 1100 lm per foot• Tunable lumen output, efficacy and lifetime• Wide case temperature (Tc) range from -40 °C to +80 °C• Push-in connectors enabling automated wiring• Five year system warranty
Retail O�ce Industry
Suitable for:
August 2015
2 - 10 Datasheet - Fortimo LED Strip Gen3 102 mm 375 lm LV3 August 2015
Commercial product name EOC 12NC
Fortimo LED Strip 102mm 375lm 830 LV3 8718291 788898 00 9290 009 00906
Fortimo LED Strip 102mm 375lm 840 LV3 8718291 788911 00 9290 009 01006
Ordering data
Fortimo LED Strip 102 mm 375 lm 830 LV3
Fortimo LED Strip 102 mm 375 lm 840 LV3
Parameter Min Typ Max Unit
Luminous flux 333 360 387 lm
Module efficiency 125 139 153 lm/W
Correlated color temperature (CCT) 3000 K
Color coordinates (CIEx, CIEy) (0.435, 0.401) -
CRI 80 -
Radiation angle 120 deg
Parameter Min Typ Max Unit
Luminous flux 347 375 403 lm
Module efficiency 130 144 158 lm/W
Correlated color temperature (CCT) 4000 K
Color coordinates (CIEx, CIEy) (0.381, 0.377) -
CRI 80 -
Radiation angle 120 deg
Optical characteristics - table per CCT
Note: Specifications stated at Tc nom = 40 °C and I nom = 136 mA. Color consistency of 3 SDCM.
Tolerance for flux data is ±7.5%.Tolerance for efficacy data is ±10%.
Note: Specifications stated at Tc nom = 40 °C and I nom = 136 mA. Color consistency of 3 SDCM.
Tolerance for flux data is ±7.5%.Tolerance for efficacy data is ±10%.
Measurement tolerance is ± 2.5% for the flux data and 5% for the efficacy data.
Drive currents and case temperatures
Parameter Nominal* Life** Max*** Unit
I (current through the LED module) 82 90 90 mA
Tc (case temperature at Tc point) 50 55 80 °C
* Nominal value at which typical performance is specified.** Value at which lifetime L70B50 ≥ 50,000 hour is specified.*** Maximum value for safe operation; do not operate above this value.
Rel
ativ
e in
tens
ity
(a.u
)
Wavelength (nm)
1
0.8
0.6
0.4
0.2
0380 430 480 530 580 630 680 730 780
830
Rel
ativ
e in
tens
ity
(a.u
)
Wavelength (nm)
1
0.8
0.6
0.4
0.2
0380 430 480 530 580 630 680 730 780
840
3 - 10 Datasheet - Fortimo LED Strip Gen3 102 mm 375 lm LV3 August 2015
Electrical characteristics
Beam shape
The Philips Fortimo LED Line generates a Lambertian beam shape, which is a pragmatic starting point for OEMs wishing to design secondary optics.
Parameter Min Typ Max Unit
Nominal current 82 mA
Forward voltage 29.9 31.8 32.9 V
Power consumption 2.5 2.6 2.7 W
Energy efficiency label A++
Minimum dimming for performance 10 %
Number of parallel modules per chain 12
Bins NA
Note: Specifications stated at Tc nom = 50 °C and I nom = 82 mA.
180°
30°30°
60°60°
90°90°
120°120°
100
200
300
400(cd/1000 lm 0° L.O.R.= 1.00
Performance over life
Lumen maintenanceOperation point Time x 1000 hours L70 L80 L90
B50 B20 B10 B50 B20 B10 B50 B20 B10
80% I-nom 66 mA Tc 25 °C > 54 > 54 > 54 > 54 > 54 > 54 51 50 49
Tc-nom 40 °C > 54 > 54 > 54 > 54 > 54 > 54 29 29 28
Tc-life 60 °C 52 50 49 32 31 31 15 15 15
I-nom 82 mA Tc 25 °C > 54 > 54 > 54 > 54 > 54 > 54 51 50 49
Tc-nom 40 °C > 54 > 54 > 54 > 54 > 54 > 54 29 29 28
Tc-life 60 °C 52 50 49 32 31 31 15 15 15
I-life 90 mA Tc 25 °C > 54 > 54 > 54 > 54 > 54 > 54 51 50 49
Tc-nom 40 °C > 54 > 54 > 54 > 54 > 54 > 54 29 29 28
Tc-life 60 °C 52 50 49 32 31 31 15 15 15
Values in the table are based on available LM80 LED data (9000h). Lumen maintenance will be updated once additional measurement data becomes available.
Parameter Min Typ Max Unit
Δu'v' at 6000 hours 0.007 -
Specifications stated while Tc < Tc-life and I < I-life.
4 - 10 Datasheet - Fortimo LED Strip Gen3 102 mm 375 lm LV3 August 2015
Abs max ratings
Parameter Min Typ Max Unit
Current Imax 90 mA
Case temperature Tc max 80 °C
ESD (direct contact) 8 kV
ESD (air) 15 kV
Ambient temperature -40 °C
+–
+–
4.6
14.6
4.5
11.2
5
4
1.65
±0.15
5.2
1.1
102 ±0.15
18.9
±0
.15
16.9
93.2 ±0.15
+–
+–
Connector to a LED Stripor Xitanium driver
Polarity Electricalproperties
12 NCproduct code
TC point forthermocouple
Approbation andconformity marking
Productname and type
Tracking and tracing code
Wiring
Mechanical characteristics
Parameter Min Typ Max Unit
Length 101.7 102.0 102.3 mm
Width 18.75 18.90 19.05 mm
Height excl. connector 1.72 1.87 2.02 mm
Height incl. connector 4.95 5.20 5.35 mm
Warpage (IPC-TM-650) 0.8 mm
Note: Bow & Twist of the PCB after production tested and released according IPC-TM-650 2.4.22.
Specification item Value Unit Condition
Input wire cross-section 0.2…0.75 mm2 Solid
18…24 AWG
0.3…0.5 mm2 Stranded
20…22 AWG
Input wire strip length 7.5…8.5 mm
Tested cable length* 4000 mm Total length of wiring including LED
modules, one way
* Note: connector suited for robot wiring.
5 - 10 Datasheet - Fortimo LED Strip Gen3 102 mm 375 lm LV3 August 2015
Application information
Compliance and approvalIEC / EN 62031, IEC / EN 62471
Photobiological safetyRisk group: Exempt
EnvironmentalRoHS / REACH
Application informationIP rating No IP rating
Overheating protection No protection
Luminaire class UL Class 2/ Class II or Class III
Warranted number of full thermal product cycles at which the survival rate of the population ≥90%, at 25 °C ambient temperature
Case temperature Tc [°C] Amount of cycles
35
40 14,600
45
50 14,600
55
60 14,600
65
70 12,000
75
80 8,000
85
90
95
6 - 10 Datasheet - Fortimo LED Strip Gen3 102 mm 375 lm LV3 August 2015
Tc [°C] Flux [%] Efficacy [%]
55 99% 100%
50 100% 100%
45 101% 101%
40 102% 101%
35 103% 102%
30 103% 102%
25 104% 103%
20 105% 103%
15 106% 104%
10 107% 104%
5 107% 105%
0 108% 105%
Flux and efficacy versus temperature at Tc
0 10 20 30 40 50 60 70 80
Tcase (°C)
110%
105%
100%
95%
90%
85%
80%
75%
70%
60%
55%
50%
Rel
ativ
e va
lue
(%)
E�cacy (%)
Flux (%)
Tuning information
Flux and efficacy versus current
0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10
LED Strip current (mA)
120%
110%
100%
90%
80%
70%
60%
50%
40%
30%
Rel
ativ
e va
lue
(%)
E�cacy (%)
Flux (%)
I [A] Flux [%] Efficacy [%]
0.090 110% 99%
0.082 100% 100%
0.073 90% 102%
0.064 80% 103%
0.056 70% 105%
0.047 60% 107%
0.039 50% 109%
7 - 10 Datasheet - Fortimo LED Strip Gen3 102 mm 375 lm LV3 August 2015
Lumen maintenance
Lumen maintenace: at I life and Tc life conditionsFortimo LED Strip 102 mm 375 lm LV3
Lumen maintenace (B50): at current I lifeFortimo LED Strip 102 mm 375 lm LV3
0% 100%
0% 100%
70%
0 10,000 20,000 30,000 40,000 50,000 60,000
B50 B10 Ref: 18W T8
Operating lifetime (hours)
Lum
en m
aint
enan
ce (
%) Lum
en dep
reciation (%
)
36,000 hours proven by certi�ed laboratory
0%
100%
70%
0 10,000 20,000 30,000 40,000 50,000 60,000
Tc nom 50 °C
Tc life 55 °C
Tc max 80 °C
Ref: 18W T8
100%
0%
Operating lifetime (hours)
Lum
en m
aint
enan
ce (
%)
36,000 hours proven by certi�ed laboratory
Lumen d
epreciatio
n (%)
Lumen depreciation as a function of operating hours for LED Strip 102 mm 375 lm LV3.
Lumen depreciation as a function of operating hours for LED Strip 102 mm 375 lm LV3 at different Tc values.
© 2015 Koninklijke Philips N.V. All rights reserved. Philips reserves the right to make changes inspecifications and/or to discontinue any product at any time without notice or obligation andwill not be liable for any consequences resulting from the use of this publication.
08/2015 Data subject to change
www.philips.com/technology www.philips.com/fortimo www.philips.com/xitanium