Date: 17012013 Rev. B
Maxis Project GABSSITE SURVEY REPORT
SITE LRD :
IMSIM1
SUB REGION : SARAWAK
Site Owner: Site Address:
SACOFA Pujut, 98000 Miri, Sarawak
Lat (N-WGS 84-Decimal): Long (E-WGS 84-Decimal): Landlord / Building Management: Surveyor: Dunstan Contact: 019-8280671 Key Info : TOC Access Hour: 24 hours
4.430350 114.019120
Limited, from _______ - ________ Yes (pls state) ______________________ No
Access Letter / LC Permit Required :
Site LRD:
IMSIM1
Address:
Pujut, 98000 Miri, Sarawak
Geographical coordinates
Lat (N-WGS 84-Decimal): Long (E-WGS 84-Decimal):
4.430350 114.019120
Ground Elevation : 8m
Mobilization / Unloading InformationIs crane required? Is skylift required? Other Constraints Yes/No No No No Size
Existing Information 1. General Information Site Type: Vacant Land If other: If other:
Sharing Type (Site Category): SACOFA Building Category: Equipment Housing: Structure Type: Structure Height: Residential Commercial CABIN VACANT LAND WITH CABIN - MONOPOLE 36m
2. 2G BTS Equipment 900 Current Vendor Equipment Model no of Equipment/BTS. No of Sector System Configuration Tx equipment/ Tx location No of physical. E1 2G BTS Equipment 1800 Current Vendor Equipment Model no of Equipment/BTS. No of Sector System Configuration Tx equipment/ Tx location No of physical. E1 3. 3G NodeB Equipment Current Vendor Equipment Model no of Equipment/BTS. No of sector (W2100) System Configuration (W2100) W900 availability No of sector (W900) System Configuration (W900) Tx equipment/ Tx location No of E1/ IP No of GE/FE spare port 4. New LTE Transmission Information Vendor Equipment Model Equipment Location
Motorola H2M 1 3 2,2,2 SRAL/ 19"RACK 2
N/A N/A N/A N/A N/A N/A N/A
Ericsson RBS 6201 1 3 1,1,1 No N/A N/A SRAL/19"RACK IP Yes No
N/A N/A N/A
5. DC Power Information Rectifier Brand & Model Existing Total DC Loading Spare Breaker (Amp) Space for additional Breaker Requirement - 4X80A No of existing power modules No of active power modules 3G DCDU / DCPDU Information DCDU / DCPDU / PDU Main incoming breaker per feed (Amp) Spare Breaker (Amp) 6. DCPDB (if available) Description DCPDB total load (sys A & B) Main incoming breaker per feed (Amp) Spare Breaker (Amp) Space for additional Breaker 7. Grounding System External Ground Bar Internal Ground Bar Grounding Cable Description Available Available Available Condition GOODNot Available
Description ELTEK 35.8 10Ax8nos, 100Ax3nos No Yes 4 4
Condition GOOD
N/A 63 1 no. / nos .
Condition
Not AvailableNot Available Not Available
8. AC Power Supply Main Source Source if tapping, indicate from where Description SESCO Condition
ACPDB Incoming Amp / Voltage Spare Breaker (Amp) Space for additional Breaker Description Available Not Available Not Available Condition GOOD
9. 2G Antenna Information: GSM900 Brand & Model Type of Antenna Sharing Antenna with Antenna Height (AGL) Antenna Azimuth Mechanical Tilt Electrical Tilt Type of Jumper Type of Feeder Connector Type Jumper Length (m) Feeder Length (m) Model of TMA Model of RET Diplexer / Triplexer Brand & Model 10. 2G Antenna Pole / Boom Information: GSM900 Pole/Boom Type ( Bipod / Tripod) Pole/Boom Height (m) Pole/Boom Diameter (upper/lower boom) (mm) Bracing Length (m) / Diameter (mm) Wall Mount / Floor Mount Arm Bracket Type / Length (m) Arm Boom Length (m) / Diameter (mm) Pole / Boom Condition Space Availability at Pole / Boom 11. Cable Ladder Information Internal Cable Ladder External Cable Ladder Other Information:
Sector 1 KATHREIN 742271 TRIBAND W2100 32M 50 0 N/A 1/2" Superflex 7/8" 7/16 Male/Female 5M x 2pcs 36M x 2pcs N/A N/A N/A
Sector 2 KATHREIN 742271 TRIBAND W2100 32M 170 0 N/A 1/2" Superflex 7/8" 7/16 Male/Female 5M x 2pcs 36M x 2pcs N/A N/A N/A
Sector 3 KATHREIN 742271 TRIBAND W2100 32M 290 0 N/A 1/2" Superflex 7/8" 7/16 Male/Female 5M x 2pcs 36M x 2pcs N/A N/A N/A
Sector 1 N/A N/A N/A N/A N/A T-BRACKET 0.5M OK NO
Sector 2 N/A N/A N/A N/A N/A T-BRACKET 0.5M OK NO
Sector 3 N/A N/A N/A N/A N/A T-BRACKET 0.5M OK NO
Size 400mm 300mm
Space Availability Available Available
12. 2G Antenna Information: GSM1800 Brand & Model Type of Antenna Sharing Antenna with Antenna Height (AGL) Antenna Azimuth Mechanical Tilt Electrical Tilt Type of Jumper Type of Feeder Connector Type Jumper Length (m) Feeder Length (m) Model of TMA Model of RET Diplexer / Triplexer Brand & Model 13. 3G Antenna Pole / Boom Information: GSM1800 Pole/Boom Type ( Bipod / Tripod) Pole/Boom Height (m) Pole/Boom Diameter (upper/lower boom) (mm) Bracing Length (m) / Diameter (mm) Wall Mount / Floor Mount Arm Bracket Type / Length (m) Arm Boom Length (m) / Diameter (mm) Pole / Boom Condition Space Availability at Pole / Boom 14. Cable Ladder Information GSM1800 Internal Cable Ladder External Cable Ladder Others Information:
Sector 1 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Sector 2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Sector 3 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Sector 1 N/A N/A N/A N/A N/A N/A N/A N/A N/A
Sector 2 N/A N/A N/A N/A N/A N/A N/A N/A N/A
Sector 3 N/A N/A N/A N/A N/A N/A N/A N/A N/A
Size 400mm 300mm
Space Availability Available Available
15. 3G Antenna Information: W900 Brand & Model Type of Antenna Sharing Antenna with Antenna Height (AGL) Antenna Azimuth Mechanical Tilt Electrical Tilt RRU CPRI Length RRU Power cable length Type of Jumper Type of Feeder Connector Type Jumper Length (m) Feeder Length (m) Model of TMA Model of RET Diplexer / Triplexer Brand & Model 16. 3G Antenna Pole / Boom Information: W900 Pole/Boom Type ( Bipod / Tripod) Pole/Boom Height (m) Pole/Boom Diameter (upper/lower boom) (mm) Bracing Length (m) / Diameter (mm) Wall Mount / Floor Mount Arm Bracket Type / Length (m) Arm Boom Length (m) / Diameter (mm) Pole / Boom Condition Space Availability at Pole / Boom 17. Cable Ladder Information W900 Internal Cable Ladder External Cable Ladder Others Information:
Sector 1 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Sector 2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Sector 3 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Sector 1 N/A N/A N/A N/A N/A N/A N/A N/A N/A
Sector 2 N/A N/A N/A N/A N/A N/A N/A N/A N/A
Sector 3 N/A N/A N/A N/A N/A N/A N/A N/A N/A
Size 400mm 300mm
Space Availability Available Available
15. 3G Antenna Information: W2100 Brand & Model Type of Antenna Sharing Antenna with Antenna Height (AGL) Antenna Azimuth Mechanical Tilt Electrical Tilt RRU CPRI Length RRU Power cable length Type of Jumper Type of Feeder Connector Type Jumper Length (m) Feeder Length (m) Model of TMA Model of RET Diplexer / Triplexer Brand & Model 16. 3G Antenna Pole / Boom Information: W2100 Pole/Boom Type ( Bipod / Tripod) Pole/Boom Height (m) Pole/Boom Diameter (upper/lower boom) (mm) Bracing Length (m) / Diameter (mm) Wall Mount / Floor Mount Arm Bracket Type / Length (m) Arm Boom Length (m) / Diameter (mm) Pole / Boom Condition Space Availability at Pole / Boom 17. Cable Ladder Information W2100 Internal Cable Ladder External Cable Ladder Others Information:
Sector 1 KATHREIN 742271 TRIBAND G900 32M 50 0 N/A N/A N/A 1/2" Superflex 7/8" 7/16 Male/Female 5m X 2 Pcs 50m X 2 Pcs ERICSSON N/A N/A
Sector 2 KATHREIN 742271 TRIBAND G900 32M 170 0 N/A N/A N/A 1/2" Superflex 7/8" 7/16 Male/Female 5m X 2 Pcs 50m X 2 Pcs ERICSSON N/A N/A
Sector 3 KATHREIN 742271 TRIBAND G900 32M 290 0 N/A N/A N/A 1/2" Superflex 7/8" 7/16 Male/Female 5m X 2 Pcs 50m X 2 Pcs ERICSSON N/A N/A
Sector 1 N/A N/A N/A N/A N/A T-BRACKET 0.5M OK NO Size 400mm 300mm
Sector 2 N/A N/A N/A N/A N/A T-BRACKET 0.5M OK NO
Sector 3 N/A N/A N/A N/A N/A T-BRACKET 0.5M OK NO Space Availability Available Available
Proposed Equipments Equipment Information Swap Type Swap Activity Equipment Type G900/W900 RF type G1800/L1800 RF type W2100 RF type L2600 RF type Type of Auxiliary Products Power Supply InformationDC Power Cable Length Grounding Cable total length AC Power Cable Length (OD Cabinet to AC source) Grounding Cable Length in total of (Outdoor Cabinet)
Cold Swap Hot Swap N/A G900 G1800/L1800 W900 W2100 L2600 DBS3900 BTS3900L BTS3900E MRFU MRFUd RRU3929 RRU3926 RRU3908 MRFU MRFUd RRU3929 WRFU RRU3829 LRFU RRU3229 APM SPB DDF Panel DCDU
13m / 4nos 10m / 1nos no. / nos no. / nos
N/A N/A N/A N/A
Additonal Information:
Transmission InformationType of Trunk Type of Connector (from BBU to DDF) BBU Trunk Cable(E1 between BBU and DDF) 2G Abis Quantity (PCS) Trunk Cable (E1) Trunk Cable (E1 between DDF and other operator DDF, if required) Type of Connector (for E1 between DDF and other operator DDF, if required) SPB Trunk Cable S1 IP Cable Length(FE cable) 75E1 L9(M) 10m
10m x 4 pcsNot Available Not Available Not Available m 2G 3G LTE 1 unit/Optica l
Existing SFP module (Electrical/Optical - max length 100m) IP >100M use optical Configura