G RANGE TILE & SLATE VENTILATORS

CI/SfB (47) Uniclass L529December 2015

Page 2: Glidevale G Range Tile & Slate Ventilators

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Glidevale profile dedicated G range tileand slate ventilators are designed to

ventilate through the roof slope and form anintegral part of the roof covering.

The tile and slate ventilators can be used atlow level or high level where the roofconstruction does not allow eaves or ridgeventilators to be used, such as wherecompartment walls or fire break wallsobstruct airflow. They are particularlysuitable for insulation upgrades when theroof covering is not being changed andrecommended by the Energy EfficiencyPartnership for Buildings as the solution forensuring adequate ventilation is provided.They are also used in complex roof shapeswhere effective cross-ventilation is not possible.

The range of ventilators can also be used assoil vent pipe or mechanical extract terminalswith separately supplied accessories.

Composition, ManufactureManufactured from ABS and polypropylenematerial for a high quality finish and robustconstruction. All exposed surfaces arecoated with a durable water based colourblended surface treatment. This surfacetreatment has been used on all GlidevaleVentilators for over 20 years, and after thistime shows only a marginal lightening ofshade which is usually counteracted by theeffect of atmospheric pollution on the roofcovering itself. All tile and ridge ventilatorshave silica sand entrained in the multi coatcoating. Slate ventilators have a smoothfinish.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

● Profile matched and colour blended in with adjacent slates, tiles and ridges as standard, making the ventilators blend intothe roofscape

● Can be installed wherever they are required as part of the normal roofing process.

● Driving rain and deluge rain resistance demonstrated by test data.

● High nett free ventilation area and low airflow resistance allow for an optimum spacing to avoid stagnant air pockets.

● Separately supplied extension sleeves ensure a clear air pathfrom the roof void to the outside to meet the design requirements of BS 5250.

● Integral 4mm large insect ingress screen.

● AA fire rating to BS 476: Part 3: 2004.

● An unrivalled range of slate and tile profiles plus a colour matching service.

● Designed and developed under BS EN ISO 9001.

BENEFITS

Page 3: Glidevale G Range Tile & Slate Ventilators

G1 Slate Ventilator

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G RANGE TILE & SLATE VENTILATORS

AppearanceThe ventilators match the roof tiles or slatesin size, shape and colour, and all types areavailable for tiles or slates. See table for fullrange of standard profiles. Tile and ridgeventilators have silica sand entrained in amulti-coat water based environmentallyfriendly uv-resistant coating, to helpweather more closely with the surroundingtiles over time. Slate ventilators have asmooth finish.

Roof pitchG Range Tile and Slate Ventilators aresuitable for roof pitches between 20° and60°. For other pitches consult our Technical Department.

Underlay Opening ProtectorSupplied with G Range tile and slateventilators to maintain the function of theunderlay where it is cut to allow for theUniversal Extension Sleeve. Any moisturethat may penetrate the roof covering higherup the slope and run down the underlay issafely diverted round the opening, incompliance with BS 5250.

Universal Extension SleeveShould always be used with G Range tileand slate ventilators. It ensures that the roofunderlay is cut and that there is acontinuous permanent weatherproof pathfrom the roof void to the outside withoutimpairing the weatherproof function of thestructure, in accordance with BS 5250.Supplied separately and snap-fits to theunderside of the ventilator on site beforethe ventilator is installed.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specification clausesVentilation of roof spaceProvide low level/highlevel roof spaceventilation by means ofGlidevale G1/G3/G5Tile/Slate Ventilators withintegral 4mm large insectscreen and AA fire ratingto BS 476: Part 3: 2004.Size/profile ..........colour........... (matched totiles/slates), and to beinstalled complete withGlidevale ExtensionSleeves and UnderlayOpening Protectors.Install at .......... mcentres as shown ondrawings to provideventilation areaequivalent to.... mm2/min accordance withBuilding RegulationsApproved Document C22004 amd 2010 & 2013and BS 5250: 2011. Fix in accordance withmanufacturer'sinstructions.

SVP/mechanical extractterminalsSoil vent pipe stacks/Mechanical extractventilation ducts to beterminated at the roofslope by means ofGlidevale G1/G3/G5Tile/Slate Ventilators,with integral 4mm largeinsect screen andcondensate grooves,and AA fire rating to BS 476: Part 3:2004.Size/profile...... colour............ (matched totiles/slates), to beinstalled complete withGlidevale UnderlayOpening Protector,GV110 Soil UniversalPipe Adaptor and FlexiPipe. Install where shownon drawings and fix inaccordance withmanufacturer'sinstructions. All joints andconnections to be airtightin accordance withBuilding RegulationsApproved Document H,and all pipes and ductsin the roof space to beinsulated.

G3 Slate Ventilator

G1 Tile Ventilator

G3 Tile Ventilator

G5 Tile Ventilator

G5 Slate Ventilator

Page 4: Glidevale G Range Tile & Slate Ventilators

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

G5 Tile and Slate VentilatorThe low-profile cowl is geometrically the smallest available inthe marketplace for the air capacity, projecting only 85mmabove the roof surface. Not recommended for high-level use as its large air capacityand wide spacing would tend to leave stagnant air pocketsbetween units (warned against in BS 5250).

PerformanceGuaranteed actual nett free ventilation area: 20 000mm2

Spacing to achieve: 10 000mm2/m; 2.0m 25 000mm2/m; 0.8m

Rigid timber sarking

Scottish practice

Underlay Opening Protector

Protect A1

50 x 50mm counterbatten to provide50mm air path

Rigid insulationat rafters

Underlay OpeningProtector

Protect VP400 Plus LRunderlay

Universal Extension Sleeve

G1 Tile and Slate VentilatorThe low-profile traditional cowl design projects only69mm above the roof surface.

PerformanceGuaranteed actual nett free ventilation area: 5000mm2

Spacing to achieve: 5000mm2/m; 1.0m10 000mm2/m; 0.5m

G3 Tile and Slate VentilatorThe low-profile cowl mirrors the popular G5 on a smallerscale, enabling use at high level in conjunction with G5 Ventilators at low level.

PerformanceGuaranteed actual nett free ventilation area: 10 000mm2

Spacing to achieve: 5000mm2/m; 2.0m10 000mm2/m; 1.0m 25 000mm2/m; 0.4m

Performance

Airflow resistance when used as SVP/extract terminals

G1 G3 G5

54m3/h (15 ltrs/sec) 18Pa 3.4Pa 0.6Pa108m3/h (30 ltrs/sec) 70Pa 11.5Pa 2.7Pa216m3/h (60 ltrs/sec) 262Pa 42Pa 11.4Pa

Soil vent pipe/mechanical extract G Range ventilators can be used asterminals for soil vent stacks ormechanical extract ventilation ducts.Condensation grooves prevent anycondensate running back down theduct. Not suitable for boiler flues.

Glidevale GV110 Pipe Adaptor Supplied separately, snap-fits to theVentilator and connects to GlidevaleFlexi Pipe to ensure an airtightconnection complying with BuildingRegulations Approved Document H.

Page 5: Glidevale G Range Tile & Slate Ventilators

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FLAT ROOF VENTILATION TERMINALS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Description, ApplicationsGlidevale Flat Roof Terminals act as outletsfor soil vent pipes, passive ventilationstacks or mechanical extract ventilationducts.There are options for installation directly onthe roof deck with integral prefabricatedupstand or for installation on a builder’skerb. They can be used for warm or colddeck roofs with built-up roofing (single ormulti-ply); with builder’s kerb they can be used with fully-supported metal roofing.The prefabricated upstand providesminimum 150mm clear upstand.Terminals have a 4mm large insect grille,and condensation grooves which preventcondensate running back down the duct.

AuthorityTerminals are designed and manufacturedto BS EN ISO 9001 and can be used tocomply with the requirements of ApprovedDocument C2, BS 5250, BS 5720 and BS 6229.

Material, ColourCowl: ABS, upstand aluminium.Slate grey as standard, or colour matchedto roof covering.

PerformanceLow resistance to airflow, see table.Also available as a ventilation unit withoutspigot, MT5U or MT5K, nett free ventilationarea 20,000mm2. Deluge and driving rainresistant as demonstrated by test.

Airflow performance

Type Spigot diam. Airflow Resistance

MT9U/100 or MT9K/100 100mm 54m3/h (15ltrs/sec) 0.6Pa108m3/h (30ltrs/sec) 2.7Pa216m3/h (60ltrs/sec) 11.4Pa

MT9U/125 or MT9K/125 125mm 54m3/h (15ltrs/sec) 1.2Pa108m3/h (30ltrs/sec) 4.8Pa216m3/h (60ltrs/sec) 19.6Pa

MT13U/150 or MT13K/150 150mm 54m3/h (15ltrs/sec) 0.32Pa108m3/h (30ltrs/sec) 1.22Pa216m3/h (60ltrs/sec) 4.86Pa300m3/h (84ltrs/sec) 9.50Pa500m3/h (139ltrs/sec) 27.37Pa

Suffix U = integral upstand, K = for builder’s kerb

Built-up or metal fullysupported roofing

Specification clauseDelete items not requiredSoil vent pipe/ Passiveventilation stack/Mechanical extractionducts to be terminatedwith Glidevale Flat RoofTerminals MT9U/MT13U/ MT9K/ MT13K,designed andmanufactured under BSEN ISO 9001, and havingintegral 4mm large insectgrille and condensategrooves. Colour: slategrey/ to match roofcovering.Install on roof deck withintegral upstand/ onsuitable builder’s kerb asshown on drawings,fixed in accordance withmanufacturer’sinstructions. All joints toductwork to be sealedand mechanicallysecured.

MT9K Terminal on builder’s kerb(MT13K dimensions are the same; only cowl profile differs)(MT5K dimensions are the same; supplied without spigot)

380 x 300mm

280 x 200mm

280mm

150mmSpigot diameter125 or 100mm

MT13U Terminal with integral upstand(MT9U dimensions are the same; only cowl profile differs)(MT5U dimensions are the same; supplied without spigot)

Prefabricatedupstand. Voidmay be filled withinsulation on siteif required

Spigot diam.150mm

Built-uproofing(single ormulti-ply)

320 x 240mm

150mm

350mm

Page 6: Glidevale G Range Tile & Slate Ventilators

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

GLIDEVALE LIMITED2 Brooklands Road, Sale, Cheshire M33 3SS Tel: 0161 905 5700 Fax: 0161 905 2085Email: [email protected] Web: www.glidevale.com

Glidevale Limited maintains a policy of continuous development and reserves the right to amend product specifications without notice.

A division of Building Product Design Ltd. Company Registration No; 3944123

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .910077 December 2015 4601

Stockist’s stamp

Composition and manufactureAll Glidevale G Range ventilators aremanufactured from upvc, polypropylene orABS for a consistently high quality finishand long lasting construction. Withexcellent weathering characteristicsGlidevale ventilators will complement anyroof for many years to come.

Building RegulationsAll Glidevale G Range ventilators can beused to comply with:

Roofspace ventilation: Building Regulations Approved Document C,BS 5250 and BS 5534.

Soil vent pipes: Building Regulations Approved Document H.

Mechanical ventilator terminal: Building Regulations Approved Document F.

Glidevale’s G Range tile and slateventilators are at the core of an unrivalledcapability. Whether you want to cover thewidest number of applications with thefewest number of references or you need tomatch the exact profile and colour for aheritage project Glidevale have the solution.Glidevale is the ‘one stop shop’ for roofventilation solutions.

STANDARD PROFILES

Aggregate IndustriesCotswold Slate 500 x 300Anchor (ForticreteRoofing Products)Anchorlite Slate*Bold RollCenturion/Senator*GeminiPlain*Stone SlateVanguard 83ViscountMini slateGemini Mk IIBallymenaMontague Plain*Penrose Mk IPenrose Mk IIPollock Double RomanCondronDouble PantileFlat‘M’ ProfileDreadnoughtPlain*Eternit Clay TilesPlain*Hardrow (ForticreteRoofing Products)686 x 457457 x 457457 x 305Hawkins (Eternit ClayTiles)Plain*Lagan TileDouble RomanFlatLangley of LondonCoutrai*Plain*Sterreberg*Marley BuildingMaterialsAnglia*AshmoreBarnstapleBold RollDominoDouble RomanEdgemereLudlow MajorLudlow PlusMalvernMarlden*Marquess*MendipModernMonarch*Plain*WessexWestwold*McLoughlinFoyletileMoyslate

MorrisseyMilfordRockfordSean QuinnCarnmoreDevenishLocherneWestern SlateRedlandCaledonianCambrian*DeltaDouble RomanDownland*Duo PlainEssexGroveburyHeathland*Mini StonewoldNorfolk Pantile*Plain*Redland 49Redland 50/BridgewaterRedland 51Redland 52RegentRenownRichmondSaxonStatesmanStonewold Mk IILandmark Double PantileRoadstoneCambrianDouble RomanFlat (Old Stonewold)Mini SlatePlain*SL8Spanish RollSlate Tile (CorkStonewold)Rosemary (Redland)Plain*RussellArgyllCheviotDerwentDouble RomanGallowayGrampianPenninePlain*Sandtoft/Goxhill 20/20Barrow Bold Roman*Bold RollBridgwaterBritlock*CalderdaleCounty Pantile*DanumDouble PantileDouble RomanEuropaFlemishGaelic*

Greenwood Pantile*Humber Plain*LincswoldLindumMercianNeo PantileOld English Pantile*Pennine 480 x 280Plain*Shire PantileStandard PatternOlympusRivusScotcemForthPentlandNorthstone (ScottToomebridge)Derrie Mk 1 and Mk 2GallowayPlain*SevilleSlemish Mk 2Villa Mk 1 and Mk 2Donard Mk 2TudorPlain*Redbank (Weatherwell)AstonBold RollBrettonConwayDaniel Platt PlainRegalSlates600 x 300500 x 250400 x 200*600 x 335 soaker style600 x 450 soaker style

*These tiles requiremultiple baseplates toensure a weatherproofinstallation.

Ventilators designed tosuit the tile manufacturers profiles listed here areavailable in eachmanufacturer’s range ofcolours. For other profilesand colours pleasecontact our TechnicalDepartment.

Company names andproduct descriptions arethe registered trade marksof the relevantmanufacturer.