Page 1: H. A. Phillips & Co. | Pump Package Control Panels

Pu

mp

Package

Co

ntro

lsP

HILLIP

SR

EFRIG

ERA

TION

H. A. Phillips & Co. | Pump Package Control Panels | PPCP-21E-01

VALVES • VESSELS • SYSTEMS • CONTROLS

770 Enterprise AvenueDeKalb, IL 60115

[email protected] 630-377-0050

Page 2: H. A. Phillips & Co. | Pump Package Control Panels

VALVES • VESSELS • SYSTEMS • CONTROLS

2 630.377.0050 [email protected]

Main Design Features:

D ƵůƟ-Valve Control Ability:

The new standard control paneloffering can operate one or two makeup valve groups. The controllercan be setup to operate the valves inparallel or series. The valves can besolenoid + motorized expansion(Danfoss ICM valves), and/or solenoid+ HEV (Hand Expansion).

ZĞŵŽƚĞŽŵŵƵŶŝĐĂƟŽŶƐǁ ŝƚŚW> K ƚŚĞƌ

The new standard control panel has a built-in4-20mA output available to pass on the level %to a central PLC or other remote monitoringdevice.

D ŽĚďƵƐZ^ϰϴϱƐĞƌŝĂůĐŽŵŵƵŶŝĐĂƟŽŶƐĂƌĞƚŚĞƐƚĂŶĚĂƌĚ ďƵŝůƚ-in means of remoteĐŽŵŵƵŶŝĐĂƟŽŶƐĂŶĚŵŽŶŝƚŽƌŝŶŐĚĚŝƟŽŶĂůŚĂƌĚǁ ĂƌĞ;ŐĂƚĞǁ ĂLJĚĞǀ ŝĐĞŝŶĂƐĞƉĂƌĂƚĞƐŵĂůůƉĂĐŬĂŐĞĚƉŽůLJĐĂƌďŽŶĂƚĞĞŶĐůŽƐƵƌĞǁ ŝƚŚĂĐĐŽŵƉĂŶLJŝŶŐŝŶƐƚƌƵĐƟŽŶƐͿĂƌĞĂǀ ĂŝůĂďůĞĨŽƌpurchase to allow for a central PLC / SCADA to communicate with the controller viaethernet. Remote enable (run) and reset inputs are also included.

Built-ŝŶWƵŵƉD ŽŶŝƚŽƌŝŶŐWƌŽƚĞĐƟŽŶ ĂŶĚƵƚŽ ǁ ŝƚĐŚŝŶŐ

The new standard control panel monitors and protects up to (3) pumps. The panel monitors the beneathŝŶƉƵƚƐ /ĨƚŚĞĐŽŶƚƌŽůƐĂƌĞƐĞƚƵƉĂƐƐƵĐŚ ƚŚĞƐƚĂŶĚďLJƉƵŵƉǁ ŝůůďĞĂƵƚŽŵĂƟĐĂůůLJƐƚĂƌƚĞĚŝĨƚŚĞƉƌŝŵĂƌLJpump(s) fails.

WƵŵƉƌƵŶĐŽŶƚĂĐƚƐ;ĐŽŶĮ ƌŵĂƟŽŶŽĨƌƵŶͿ

Pump motor current (protects against too high or too low amps)

ŝī ĞƌĞŶƟĂůƉƌĞƐƐƵƌĞ;ĨŽƌĐĂǀ ŝƚĂƟŽŶĂǀ ŽŝĚĂŶĐĞ ƉƌŽƚĞĐƟŽŶͿ

Pump Bypass Solenoid and Transfer Solenoid:

The new standard control panel has built-in outputs available for a pump bypass solenoid (for pump minflow), always energized while pump(s) are running, and a transfer solenoid output that energizes if the liquid level gets too high (as set in controller parameters).

Built-in VFD Fixed Speed Control:

The new standard control panel can operate a VFD at a fixed speed (ramps up from min to max setpoints).

Page 3: H. A. Phillips & Co. | Pump Package Control Panels

VALVES • VESSELS • SYSTEMS • CONTROLS

[email protected] 630.377.0050

Main Design Features Cont...

Door Mounted % Full LED Bar Graph, and User Interface Module (Remote Keypad/Display):

Pumps and Level Inputs Flexibility:

The controls can accommodate up to three (3) pumps. In a typical two (2) pump setup one pump is set torun while the other is set to standby. In a typical three (3) pump setup two of the pumps are running withone in standby.

dŚĞĐŽŶƚƌŽůƐĐĂŶƵƟůŝnjĞĂϰ-20mA level probe signal and/or float/single point switch digital inputs.

ĞƚĂŝůĞĚŝƐƉůĂLJ/ŶĨŽƌŵĂƟŽŶ

The new standard display (both the internally mounted controller and the remote door display) showĚĞƚĂŝůĞĚŝŶĨŽƌŵĂƟŽŶ ĂŶĚĂůůŽǁ ĨŽƌĞĂƐLJƵƐĞƌŝŶƚĞƌĨĂĐŝŶŐ&ŽƌĨƵůůŝŶĨŽƌŵĂƟŽŶƉůĞĂƐĞƌĞĨĞƌƚŽƚŚĞĂŶĨŽƐƐ“MCX Vessel Liquid Level Controller User Guide”.

Page 4: H. A. Phillips & Co. | Pump Package Control Panels

Pu

mp

Pac

kage

Co

ntr

ols

PH

ILLI

PS

REF

RIG

ERA

TIO

N

H. A. Phillips & Co. | Pump Package Control Panels | PPCP-21E-01

dŚƌĞĞdLJƉŝĐĂůsĂƌŝĂƟŽŶƐǀ ĂŝůĂďůĞ;/ŶWĂŝŶƚĞĚ ƚĞĞůŽƌ ^Ϳ

CRNMany Products

Registered

ASME "R" Bureau Veritas ISO 9001: 2015EĂƟŽŶĂůŽĂƌĚASME "U"

RETA MemberIIAR Member

ĂƐĞŽŶƚƌŽůWĂŶĞůKƉƟŽŶ;ŶŽƉƵŵƉƉŽǁ ĞƌĐŽŵƉŽŶĞŶƚƐͿ

Painted steel enclosure (NEMA 4) grey or Stainless Steel enclosure(NEMA 4X). 24”H x 20”W x 8”D

120V AC/60HZ/1PH power feed required to panel (for special powerrequirements contact factory)

Wireway, field terminals, markers, etc. & Wiring diagram

UL & cUL labels, per UL-508A

dĞŵƉĞƌĂƚƵƌĞZĂƟŶŐϯϮΣ&- 104°F

KƉƟŽŶĂůƐŚŝƉ-ůŽŽƐĞĂůĂƌŵŚŽƌŶ ϭϭϯĚ;ͿΛ ϯ ϯŌ

WĂŶĞůǁ ŝƚŚd>WƵŵƉ ƚĂƌƚĞƌƐKƉƟŽŶ

Painted steel enclosure (NEMA 4) grey or Stainless Steelenclosure (NEMA 4X). Approximate enclosure size is 42”H x 30”Wx 10”D

460V AC/60HZ/3PH power feed required to panel (for specialpower requirements contact factory)

Door Mounted Eaton Main Disconnect device (bypassable andůŽĐŬĂďůĞŝŶƚŚĞŽī ƉŽƐŝƟŽŶͿ

Wireway, field terminals, markers, etc. & Wiring diagram

UL & cUL labels, per UL-508A

dĞŵƉĞƌĂƚƵƌĞZĂƟŶŐϯϮΣ&- 104°F

dǁ Ž;ϮͿĂŶĚdŚƌĞĞ;ϯͿƉƵŵƉǀ ĂƌŝĂƟŽŶƐĂǀ ĂŝůĂďůĞĨŽƌŵƵůƟƉůĞmotor power ranges:

(2) Pumps <10A, 1hp – 5hp

(3) Pumps <10A, 1hp – 5hp

(2) Pumps 10A – 30A, 7.5hp – 20hp

(3) Pumps 10A – 30A, 7.5hp – 20hp

(2) Pumps 30A – 50A, 25hp – 40hp

(3) Pumps 30A – 50A, 25hp – 40hp