Handouk Electronics Co., Ltd. All rights reserved. Inner Relay coil Resistance Nominal Voltage (VDC) Pick-up Voltage VDC Drop-out Voltage VDC Max. Allowable Voltage VDC Coil Resistance Ω ×(1±10%) Protection turn on time 20ms 20ms Relay Relay turn off Protection Figure 1. Turn on resistance to time Figure 2. time sequence of relay protection Figure 3. Maximum switching power Figure 4. Endurance Curve Figure 3. Maximum switching power Figure 4. Surge on-state current (non receptivity) (non receptivity) Protection Relay turn on 3/4
Citation preview
Copyright@ Handouk Electronics Co., Ltd. All rights reserved.
ZCR16D_1A_V10ZCR16D_1A_V10Analogue Zero Crossing Relay
Contact DataContact Data
Dec. 2008. Rev. 01 1/4
• Input : 12VDC• Output : 16A, 200VDC• Surge current @ start : 44A
1 : DC_IN 2 : DC_OUT3 : GND 4 : VCTRL 5 : VCC
Characteristics ValuesContact arrangement 1AContact material AgNi,AgSnO2Contact Ratings (Res. Load) 16A 200VDCMechanical endurance 5X107opsElectrical endurance 1 X 105ops
Main Features
Switching capability : 16A Maximum Surge voltage (between coil and contacts):6kV Thermal class F: standard type (at 85 ) Product in accordance to IEC 60335-1 available 1 From A configurations available Wash tight and flux proofed types available Transient peak current : 44A (at starting) Environmental friendly product (RoHS compliant) Outline Dimensions on bottom (46.0mmX33.0mm)
Description and application These DC zero crossing relay, ZCR16D_1A_V10, contains handouk electronic’s metal contact-protection function, so life time is several times longer than normal relay and its surge on state current at start mode is around 44A, and switching noise at start and switching mode is ultimately limited in switching mode. This is well suitable for high stressing load such as DC motor control which is applied to relay at the starting mode or every switching cycles.
Electrical characteristics IElectrical characteristics I(Start mode ; relay protection period)(Start mode ; relay protection period)
Characteristics Condition Values unit
Maximum voltage - 200 V
Maximum current - 11 A
Maximum surge current - 44 A
Power dissipation TC=25oC 125 W
Maximum turn on resistance VCTRL = 12V, ILOAD=6A 0.5 Ω
Maximum turn on voltage drop ILOAD=11A 5.0 V
Starting to relay turn on period VCTRL = 12V 20 ms
1 3
25
4
Copyright@ Handouk Electronics Co., Ltd. All rights reserved.
Inner Relay characteristicsInner Relay characteristics
Input characteristicsInput characteristics
Characteristics Values
Insulation Resistance 100M( at 500VDC)
DielectricStrength Between
coil & Contacts 3,000Vrms 1min.
open Contacts 1000Vrms 1min.
Surge voltage 6kV(1.2*50µs) (between coil & contacts)
Operate Time (at nomi. volt) 10ms max.
Release Time (at nomi. volt) 5ms max.
ShockResistance
Functional 98m/s2
Destructive 980m/s2
Vibration Resistance 10 Hz ~ 55Hz 1.5mm DA
Humidity 35 ~ 85% RH
Ambient temperature -40% to 105%
Termination PCB
Unit Weight Approx .29g
Construction Wash tight, Flux proofed
Coil power 360mW
ZCR16D_1A_V10ZCR16D_1A_V10Electrical characteristics IIElectrical characteristics II(Normal relay operation after relay protection mode)(Normal relay operation after relay protection mode)
Characteristics Condition Values unit
Maximum switching voltage - 200 V
Maximum switching current - 16 A
Maximum switching power - 3200 W
Maximum turn on resistance ILOAD=11A 100 mΩ
CharacteristicsCharacteristics SymbolSymbol ConditionCondition ValuesValues UnitUnit
Input voltage VIN Input impedance : 4.8KOhm 12 V
Control Voltage
Minimum
VCTRL VIN = 12V
8
VTypical 12
Maximum 24
Maximum Junction Temperature TJ - 125 oC
2/4
Copyright@ Handouk Electronics Co., Ltd. All rights reserved.
Inner Relay coil ResistanceInner Relay coil Resistance
Nominal Voltage(VDC)
Pick-upVoltage
VDC
Drop-outVoltage
VDC
Max.AllowableVoltage
VDC
CoilResistance
Ω
12 9.00 1.2 14.4 400×(1±10%)
20 40 60 80 10010-2
10-1
100
Turn
on
Res
ista
nce[
ohm
]
Time [ms]
Protection Protection turn onturn on
timetime20ms20ms
20ms20ms
Relay Relay turn onturn on
Relay Relay turn offturn off
Protection Protection turn offturn off
Figure 1. Turn on resistance to timeFigure 1. Turn on resistance to time Figure 2. time sequence of relay protectionFigure 2. time sequence of relay protection
1 10 100 10001
10
Con
tact
Cur
rent
[A]
Contact Voltage[V]
Figure 3. Maximum switching powerFigure 3. Maximum switching power
0 2 4 6 8 10 12 14 16 18 201
10
100
1000
277Vac Resistor load
Ope
ratio
ns (
X 1
0,00
0 op
s)
Contact current [A]
125Vac Resistor load
Figure 4. Endurance CurveFigure 4. Endurance Curve
80 90 100 110 120 13020
25
30
35
40
45
Tem
pear
ture
[K]
Percentage of nominal coil Voltage
Figure 3. Maximum switching powerFigure 3. Maximum switching power
1 2 3 4 5 6 7 8 9 1020
40
60
80
100
120
140
160
180
200
Sur
ge o
n-st
ate
curr
ent [
A]
Time [cycles]
Figure 4. Surge on-state currentFigure 4. Surge on-state current (non receptivity)(non receptivity)
Protection
Relay turn on
3/4
Copyright@ Handouk Electronics Co., Ltd. All rights reserved.
ZCR16D_1A_V10ZCR16D_1A_V10
4/4
Figure 4. Typical Application
DC
GND
VIN(DC)
VCTRL
LOADLOAD
RELAY
Ordering informationOrdering information
DimensionDimension
33.00
13.505.50
2.50
46.00
18.0014.00
DC_IN
DC_OUT
GND
CTRL
VCC
HanDouk’s HanDouk’s zero crossing Relayzero crossing Relay
Current ratingCurrent rating Form Contact Form Contact
ZCR 16D _ 1A