grade GRADE grade grade 35'-4 5/16" 25'-5 7/8" STONE VENEER 26'-5 1/16" 6" batten 4" batten asphalt shingles asphalt shingles ASPHALT SHINGLES TOP OF SLAB STUCCO stucco 6" BATTEN AROUND WINDOWS & DOORS 6" batten around windows & doors MAIN FLOOR 6" BATTEN 6" BATTEN MAIN FLOOR CEILING 10'-1" 10'-1" 4" BATTEN 42" railing 2'-1" 18" TYP. 18" typ. 10 10 10 10 10 10 12 12 12 12 12 12 THIS DRAWING IS COPYRIGHT AND MUST NOT BE USED, REPRODUCED, OR REVISED WITHOUT WRITTEN PERMISSION
Citation preview
12
10
12
10
12
1025'-5 7/8"
16'-0 5/16"
2'-1"
26'-5 1/16"
10'-0"
10'-1"
ASPHALT SHINGLES
6" BATTEN
4" BATTEN
6" BATTEN AROUNDWINDOWS & DOORS
MUNTIN BARS ASSHOWN TYP.
18" TYP.
6" BATTEN
STONE VENEER
TOP OF SLAB
MAIN FLOOR
MAIN FLOOR CEILING
GRADE
STUCCO
grade
12
10
12
10
10
12
35'-4 5/16"
10'-0"
10'-1"
asphalt shingles
18" typ.
6" batten aroundwindows & doors
42" railing
30"x30"stonecolumn
muntin bars asshown typ.
stucco
asphalt shingles
6" batten4" batten
grade
grade
FILE NUMBER 11 057
5
DRAWN: M.S.PCHECKED ---COMPLETED Dec 8 2011
SCALE3/16" = 1'-0"
DRAWING TITLE
THIS DRAWING IS COPYRIGHT AND MUST NOT BEUSED, REPRODUCED, OR REVISED WITHOUTWRITTEN PERMISSION
ALL DIMENSIONS ARE IN FEET AND INCHES UNLESSOTHERWISE NOTED. VERIFY DIMENSIONS.DO NOT SCALE THIS DRAWING
REPORT INCONSISTENCIES AND OMISSIONS TOMODERN DRAFTING & DESIGN FOR CLARIFACTIONBEFORE COMMENCING WITH THE WORK
DEVIATIONS FROM THE CONTRACT DOCUMENTSWITHOUT WRITTEN APPROVAL FROM MODERNDRAFTING & DESIGN ARE SUBJET TO CORRECTIONAT THE CONTRACTORS EXPENSE
IMPERIAL
NO. DATE DESCRIPTION 1.2.3.4.5.
RELEASE/REVISIONS
MAIN FLOOR - 2229 sq. ft.SECOND FLOOR - n/aTOTAL AREA - 2229 sq. ft.BASEMENT - 1876 sq. ft.
FRONT PORCH - 40 sq. ft.REAR DECK - 533 sq. ft.BALCONY - n/aGARAGE - 1683 sq. ft.
SQUARE FOOTAGE
FRONT ELEVATION
REAR ELEVATION
01
harkins residence
12
7
7
12
30'-10 11/16"
26'-5 1/16"
35'-4 5/16"
10'-0"
10'-1"
parging
stucco
asphalt shingles
18" 18"18"
main floor
top of slab
main floor ceiling
grade
grade
7
12 12
7
10'-0"
10'-1"
26'-5 1/16"
35'-4 5/16"
30'-10 11/16"
parging
stucco
asphalt shingles
18" 18" 18" 18"
grade
grade
main floor
top of slab
main floor ceiling
12
10
12
10
18"
18" 18"
18"
18"18"
asphalt shingles
stucco
grade
7
12
12
7
25'-5 7/8"
grade
stucco
asphalt shingles
18" 18" 18"
18"
FILE NUMBER 11 057
5
DRAWN: M.S.PCHECKED ---COMPLETED Dec 8 2011
SCALE3/16" = 1'-0"
DRAWING TITLE
THIS DRAWING IS COPYRIGHT AND MUST NOT BEUSED, REPRODUCED, OR REVISED WITHOUTWRITTEN PERMISSION
ALL DIMENSIONS ARE IN FEET AND INCHES UNLESSOTHERWISE NOTED. VERIFY DIMENSIONS.DO NOT SCALE THIS DRAWING
REPORT INCONSISTENCIES AND OMISSIONS TOMODERN DRAFTING & DESIGN FOR CLARIFACTIONBEFORE COMMENCING WITH THE WORK
DEVIATIONS FROM THE CONTRACT DOCUMENTSWITHOUT WRITTEN APPROVAL FROM MODERNDRAFTING & DESIGN ARE SUBJET TO CORRECTIONAT THE CONTRACTORS EXPENSE
IMPERIAL
NO. DATE DESCRIPTION 1.2.3.4.5.
RELEASE/REVISIONS
MAIN FLOOR - 2229 sq. ft.SECOND FLOOR - n/aTOTAL AREA - 2229 sq. ft.BASEMENT - 1876 sq. ft.
FRONT PORCH - 40 sq. ft.REAR DECK - 533 sq. ft.BALCONY - n/aGARAGE - 1683 sq. ft.
SQUARE FOOTAGE
RIGHT ELEVATION
LEFT ELEVATION
02
garage frontgarage left
9060
7068
9060
5080
3068
3068
5068
2868
4256
3068
4260
2668
2020 2020
56100
7060
5068
2668
2668
3068
5068
2060
2668
2668
4068
8080
4260
100140
18080
9080
4260
4260
4260
3068
4260
4260
2060
2468
4260
2040
2868
2868
D/W
INSULATEDATTICACCESS
INSULATED
ATTIC
ACCESS
R
R
R
R
R
R
R
RR
R
R
R
R
R
R R
R
RR
R R
RR
R
R
R R R
R
R RR
3
3
3
3
3
C
C
3
C 3
C
T3
3
3
3
3
3
33
33
3
33
MASTER BDRM16'-5" x 14'-8"
OFFICE11'-0" x 9'-3"
DINING13'-0" x 14'-11"
NOOK14'-10" x 10'-1"
GARAGE26'-7" x 41'-2"
DECK46'-4" x 9'-8"
great room12'-4" x 18'-0"
8'-3 1/2"
4'-0"
9'-5"
8'-4"
1'-8"
15'-0"
22'-3 1/2"
22'-2 1/2"
8'-8"1'-0 1/2"
15'-0 1/2" 13'-11"
8'-8" 4'-0" 4'-3"
8'-3" 5'-0" 5'-8" 5'-9 1/2"
7'-9" 5'-6"
9'-11"2'-1"1'-11"8'-3 1/2"
3'-6"
3'-11"
18'-1"
26'-5"
2'-0"
10'-0"
8'-1"
7'-5"
3'-7"
15'-5"
4'-0"8'-10"8'-9"
9'-0
"
15'-7
"
9'-0
"
7'-0"
7'-0"
7'-6"
8'-6"
3'-0"
19'-0"
21'-7"
2'-0"
14'-0
"
33'-7
"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
45'-0"
15'-0"
15'-0"
15'-0"
6'-0
"
6'-0
"
11'-0
"
11'-0
"
7'-0"
7'-0"
48'-0
"
2'-0"
14'-0
"
22'-0
"
12'-0
"
1'-0"
6'-0 1/2"
6'-0 1/2"
4'-0"
6'-3" 3'-6" 7'-3" 5'-11" 6'-0" 4'-0" 4'-0" 2'-3" 9'-5" 2'-3"
50'-10"
1'-6"
3'-11" 13'-1" 11'-11" 8'-0" 13'-11"
23'-11"
8'-3"
16'-4"
5'-6"
43'-0"
2'-0"
48'-6"
1'-0"
12'-0"
16'-9" 15'-0" 15'-2"
46'-11"1'-0"
4'-0" 8'-8" 8'-1" 7'-6" 7'-6" 7'-7" 7'-7"
1'-6"
6'-0"
4'-0"
6'-9"
7'-4"
5'-0"1'-0"
8'-3"
13'-4"
3'-2"
3'-7"
6'-6"
5'-11"
6'-0"
4'-0"
14'-1"
4'-0"
dn 18r
ledge
2x6 plumbing
adjust width asper f.p. specs
r=80"
r=3
8"
eng b
eam b
y su
pplie
r
3-2X
12 sp
f#2
3-2X
12 sp
f#2
adjust width asper f.p. specs
butlerspantry
barrel vault
arch
arch
arch
arch
arch
arch
bench
EXTERIOR DOOR C/W CLOSER
& WEATHERSTRIPPING
dn 3r
GARAGE NOTE:ALL GARAGE WALLS & CEILINGTO BE INSULATED, POLY,DRYWALLED & ONE COAT TAPE
SLOPE SLA
B 4" TO
O/H D
OOR
SLOPE SLA
B 4" TO
O/H D
OOR
2-way DIRECT VENTGAS FIREPLACE
DIRECT VENTGAS FIREPLACE
sd
co2
db
135H
135H
3r
3-2X
12 sp
f#2
bulkhead
light
fan
light
fan
light
fan
120vjunctionbox
120vjunctionbox
fanr.i.
gas
gas line
drain w
/ sum
p
locat
ion
tbd o
n site
drain w
/ sum
p
locat
ion
tbd o
n site
40 amp panel
heated tile floor
carpet
carpet
dn 13r
tile
tile
tile
hardwood
hardwood
hardwood
hardwood
hardwood
light
fan3
3 3 3
bbq gas line
WINDOW INSTALLATION DETAIL
3/8" WALL SHEATHING
(AS PER BUILDING CODE 9.23.16.2)
A
1 LAYER OF SHEATHING MEMBRANE
(OVERLAP SHEATHING MEMBRANCE 4")
(AS PER BUILDING CODE 9.23.17)
WINDOW INSTALLATION DETAIL
1 LAYER OF SHEATHING MEMBRANE
(OVERLAP SHEATHING MEMBRANCE 4")
3/8" WALL SHEATHING
(AS PER BUILDING CODE 9.23.17)
(AS PER BUILDING CODE 9.23.16.2)
B
WINDOW INSTALLATION DETAIL
1 LAYER OF SHEATHING MEMBRANE
(OVERLAP SHEATHING MEMBRANCE 4")
3/8" WALL SHEATHING
(AS PER BUILDING CODE 9.23.17)
(AS PER BUILDING CODE 9.23.16.2)
C
FLASHING TO GO UP WALL 2" MIN.
(AS PER BUILDING CODE 9.27.3)
WINDOW INSTALLATION DETAIL
1 LAYER OF SHEATHING MEMBRANE
(OVERLAP SHEATHING MENBRANE 4")
3/8" WALL SHEATHING
(AS PER BUILDING CODE 9.23.17)
(AS PER BUILDING CODE 9.23.16.2)
D
FLASHING TO GO UP WALL 2" MIN.
(AS PER BUILDING CODE 9.27.3)
PEAL & STICK ON TOP OF FLANGES
SHEATHING MEMBRANE TO BE TACKED
INSIDE BOTTOM OF WINDOW OPENING
(AS PER BUILDING CODE 9.23.17)
SHEATHING MEMBRANE TO BE PEALED
BACK ABOVE WINDOW. FLASHING SECURED
ABOVE WINDOW WITH PEEL AND STICK
MEMBRANE PLACED OVER TOP. SHEATHING
MEMBRANE TO BE PUT BACK OVER TOP OF
FLASHING AND PEEL AND STICK MEMBRANE.
SECONDARY LAYER OF PEEL &
STICK MEMBRANE PLACED OVER
TOP OF FLASHING.
STUCCO LATH DETAIL
9.28.3.11. FASTENERS FOR STUCCO LATH SHALL BE CORROSION-RESISTANT ANDMADE OF A METERIAL OTHER THAN ALUMINUM
9.28.3.2 NAILS AND STAPLES1. NAILS FOR STUCCO LATH OR REINFORCING SHALL BE NOT LESS THAN 3.2 MMDIAM. WITH A HEAD DIAMETER OF NOT LESS THAN 11.1 MM2. STAPLES FOR STUCCO LATH OR REINFORCING SHALL BE NOT LESS THAT1.98 DIAM. OR THICKNESS3. STAPLES AND NAILS FOR ATTACHING STUCCO LATH OR REINFORCING TOVERTICAL SURFACES SHALL BE OF SUFFICIENT ENOUGH TO PENETRATE 25MMINTO FRAMING MEMBERS OR TO THE FULL DEPTH OF THE SHEATHING WHERETHE SHEATHING IS USED FOR ATTACHMENT.4. ON HORIZONTAL SURFACES NAILS FOR STUCCO LATH OR REINFORCINGSHALL NOT BE LESS THAN 38 MM LONG.
9.28.4 STUCCO LATH9.28.4.1 MATERIALS1. RIB LATH OR EXPANDED METAL STUCCO MESH SHALL BEA) COPPER-ALLOY STEEL COATED WITH RUST-INHIBITIVEPAINT AFTER FABRICATION ORB) GALVINIZED2. WOVEN OR WELDED WIRE MESH SHALL BE GALVINIZED
9.28.4.3 STUCCO LATH SPECIFICATIONS1. STUCCO LATH SHALL CONFORM TO TABLE 9.28.4.3
HORIZONTAL AND VERTICALJOINTS OF METAL LATHSHOULD BE NO LESS THAN50 MM (2") AND THE LONGDIMENSION OF THE LATHAPPLIED HORIZONTAL
LATH FASTENINGPER ABC 9.28.4.6150 MM (6") O.C. VERTICALLY400 MM (16") O.C. HORIZONTALLYOR100 MM (4") O.C. VERTICALLY600 MM (24") O.C. HORIZONTALLYWITH NO FEWER THAN 20 FASTENERS PER SQ. METER
STUCCO FINISH TO MIN. OF NOTLESS THEN 2 BASE COATS ANDONE FINISH COAT PROVIDING ATOTAL THICKNESS OF NOT LESSTHAN 15MM OR 1/4" FROM FACEOF LATH OR FACE OF MASONRYWHERE LATH IS NOT REQ.
WALL SHEATHINGMEMBRANE DETAIL
9.23.17.1 MATERIAL STANDARD. SHEATHING PAPER SHALL CONFORMTO CAN2051.32 "SHEATHING, MEMBRANE, BREATHER TYPE."9.23.17.3 REQUIRED SHEATHING MEMBRANE AND INSTALLATION
1. EXPECT AS PROVIDED IN ARTICLES 9.23.17.4-5-6 AT LEAST ONELAYER OF SHEATHING MEMBRANE SHALL BE APPLIED BENEATHSIDING, STUCCO, OR MASONARY VENEER2. SHEATHING MEMBRANE REQUIRED IN SENTENCE 1 SHALL BEAPPLIED SO THAT THE JOINTS ARE LAPPED NOT LESS THEN 4" (100MM)3. WHERE SHEATHING MEMBRANE REQUIRED SENTENCE 1 IS APPLIEDHORIZONTALLY, THE UPPER SHEETS SHALL OVERLAP THE LOWERSHEETS.4. ALL JOINTS IN THE SHEATHING PAPER REQUIRED IN SENTENCE 3SHALL OCCUR OVER FRAMING, AND THE PAPER SHALL BEFASTENED TO THE FRAMING WITH ROOFING NAILS OR STAPLESSPACED NOT MORE THEN 6" (150 MM) ALONG THE EDGES OF THEOUTER LAYER OF SHEATHING PAPER
FASTEN NAILS OR STAPLESAT NO MORE THAT 6" (150MM) APART
FIRST COURSEOF REQUIRED.BUILDING PAPER
SECOND COURSEOF REQUIRED.BUILDING PAPER
THIRD COURSE OFREQUIRED.BUILDING PAPER
OVERLAP (MIN)
OVERLAP (MIN)
OVERLAP (MIN)
CONTINUE COURSESTO TOP OF WALL(AS REQUIRED)
4"
4"
4"
WALL SHEATHINGGAP DETAIL
9.23.16.2 THICKNESS RAITING AND MATERIAL STANDARDS1. WHERE WALL SHEATHING IS REQUIRED, IT SHALL CONFORM TOEITHER TABLE 9.23.16.2.A, OR TABLE 9.23.16.2.B
2. WOOD BASED PANELS USED FOR WALL SHEATHINGCONFORMING TO TABLE 9.23.16.2.B SHALL BE PRODUCED ATMILLS OPERATING A QUALITY ASSURANCE PROGRAMMECONFORMING TO CSA-0325.2-M "QUALITY ASSURANCE FORCONSTRUCTION SHEATHING. "
SHEATHING FASTENINGPER ABC TABLE 9.23.3 B150 MM (6") O.C. ALONG EDGES30 MM (12") O.C. ALONGINTERMEDIATE SUPPORTS
SHEATHINGPER ABC 9.23.16ALLOW MIN 3/32" (2 MM)GAP BETWEEN SHEATHING(TOP/BOTTOM & SIDES)
MIN 3/8" (7.5 MM)THICKNESS OFEXTERIOR SHEATHING
continue coursesto top of wall(as reqired)
FILE NUMBER 11 057
5
DRAWN: M.S.PCHECKED ---COMPLETED Dec 8 2011
SCALE3/16" = 1'-0"
DRAWING TITLE
THIS DRAWING IS COPYRIGHT AND MUST NOT BEUSED, REPRODUCED, OR REVISED WITHOUTWRITTEN PERMISSION
ALL DIMENSIONS ARE IN FEET AND INCHES UNLESSOTHERWISE NOTED. VERIFY DIMENSIONS.DO NOT SCALE THIS DRAWING
REPORT INCONSISTENCIES AND OMISSIONS TOMODERN DRAFTING & DESIGN FOR CLARIFACTIONBEFORE COMMENCING WITH THE WORK
DEVIATIONS FROM THE CONTRACT DOCUMENTSWITHOUT WRITTEN APPROVAL FROM MODERNDRAFTING & DESIGN ARE SUBJET TO CORRECTIONAT THE CONTRACTORS EXPENSE
IMPERIAL
NO. DATE DESCRIPTION 1.2.3.4.5.
RELEASE/REVISIONS
MAIN FLOOR - 2229 sq. ft.SECOND FLOOR - n/aTOTAL AREA - 2229 sq. ft.BASEMENT - 1876 sq. ft.
FRONT PORCH - 40 sq. ft.REAR DECK - 533 sq. ft.BALCONY - n/aGARAGE - 1683 sq. ft.
SQUARE FOOTAGE
MAIN FLOOR PLAN
03
SURPLUS METAL FOLDED BEHIND
UPTURNED METAL EDGE
LIP OR HEMMED EDGE
SLOPED FLASHINGEXTENDED 1" 25MM BEYOND WINDOW
1103" 3/4 76MM 7/8
N.T.S.
DRIP EDGE FLASHING
N.T.S.
DRIP EDGE END DETAIL
NOTE: END-DAMS AND/OR SLOPED FLASHINGS ARE REQUIRED ON HEADFLASHING TO PREVENT MOISTURE FROM ENTERING THE STUCCO AT JAMB AREAEND-DAMS SHALL BE COMPATIBLE WITH THE HEAD FLASHING MATERIAL
ELEVATION NOTES
BASEMENT NOTES
MAIN & SECOND FLOOR NOTES1. BUILDER MUST CHECK & VERIFY ALL DETAILS & REPORT ANY DISCREPANCIES TO "modern drafting & design ltd." PRIOR TO ANYCONSTRUCTION.2. FINAL GRADES MAY ALTER EXTERIOR APPEARANCE.3. ALL EXTERIOR LINTELS TO BE 2 - 2x10 SPF #2 UNLESS SPECIFIED.4. CONSTRUCTION SHALL CONFORM TO THE ALBERTA BUILDING CODE AND LOCAL BUILDING BY-LAWS.5. WINDOW & DOOR SIZES 4640 (4'- 6"x 4'- 0")6. WALLS ARE DIMENSIONED TO EDGE OF FRAMING. OPENINGS ARE DIM. TO CENTRE OF R.O.7. PROVIDE EXTERIOR VENTING FOR ALL FANS & RANGE HOOD.8. 20"x 28" ATTIC ACCESS TO BE WEATHESTRIPPED & INSULATED.9. TOP OF DECK TO BE 3" BELOW TOP OF FLOOR UNLESS NOTED.
1. BUILDER MUST CHECK & VERIFY ALL DETAILS & REPORT ANY DISCREPANCIES TO "modern drafting & design ltd." PRIOR TO ANYCONSTRUCTION.2. FINAL GRADES MAY ALTER EXTERIOR APPEARANCE.3. CONTRACTOR TO DETERMINE SOIL CONDITIONS ARE SUITABLE BEFORE START OF CONSTRUCTION.4. CONSTRUCTION SHALL CONFORM TO THE ALBERTA BUILDING CODE AND LOCAL BUILDING BY-LAWS.5. PROVIDE SLEEVES THRU CONC. AS REQUIRED FOR F/A & C/A VENT FOR FURNACE.6. DECK DROPPED 3" BELOW FLOOR & SLOPED FOR DRAINAGE.7. ELECTRICAL PANEL TO BE LOCATED AS NEAR FURNACE AS POSSIBLE UNLESS NOTED.8. ALL FOOTINGS TO BE A MIN. OF 4' BELOW GRADE. STEP CONC. AS REQUIRED.
1. BUILDER MUST CHECK & VERIFY ALL DETAILS & REPORT ANY DISCREPANCIES TO "modern drafting & design ltd." PRIOR TO ANYCONSTRUCTION.2. FINAL GRADES MAY ALTER EXTERIOR APPEARANCE.3. CONSTRUCTION SHALL CONFORM TO THE ALBERTA BUILDING CODE & LOCAL BUILDING BY-LAWS.4. TOP OF DECK TO BE 3" BELOW TOP OF FLOOR UNLESS NOTED.5. 18" OVERHANG C/W PREFINISHED SOFFIT & FASCIA UNLESS NOTED.6. ROOF SHALL BE VENTED AS PER THE ALBERTA BUILDING CODE.7. ALL WINDOW & DOOR TOPS TO HAVE FLASHING.
ROOF NOTES
1. 6" PREFINISHED FASCIA2. PREFINISHED EAVESTROUGH3. TRUSS SUPPLIER TO VERIFY ALL ROOF SLOPES AND TRUSS DESIGN PRIOR TO FABRICATION
1. OPENINGS UP TO 6'- 0" 2-2x8 SPF #22. OPENING OVER 6'- 0" 2-2x10 SPF #2 (UNLESS NOTED OTHERWISE)
OPENING NOTES
SEE PLANS FOR SPANS OVER 8'.
2 - 2x82 - 2x10
1' - 6'6' - 8'
WINDOWS &DOORS
LINTEL SPANS
NUMBER OF FULL HEIGHT 2x6STUDSREQUIRED PER SIDE OF WINDOWOPENINGS 4' TO 12' WIDELOADBEARING WALLS UP TO 3STACKED WINDOWS
TALL WALL DETAIL
BOTH CASES = 3 NAILS/STUD.
LOADBEARING WALLS NOOPENINGS2x6 @ 16" o/c FULL HEIGHTSTUDSMAX. WALL HEIGHT OF 18' - 2".
NOTES:
3 - 2x63 - 2x64 - 2x64 - 2x65 - 2x67 - 2x67 - 2x6
W = 4' - 0"W = 4' - 8"W = 6' - 0"W = 7' - 0"W = 8 - 0"W = 10 - 0"W = 12 - 0"
WALL CONFIG2x6 @ 12" o/c
OPENINGWIDTH
19' - 9" MAX. HEIGHT
14' - 0" MAX. HEIGHT
W
SEE LINTEL SPANS
OPENING
LOCATIONS AS PER CURRENT ELECTRICALCODE & AS SPECIFIED ON PLANS.
SOFFIT OUTLET
220V OUTLET
SWITCHED OUTLET
WEATHERPROOF OUTLET
DUPLEX OUTLET
DOOR CHIME
VACU-FLOW OUTLET
THERMOSTAT
SMOKE DETECTOR
CABLE TV OUTLET
TELEPHONE JACK
VENTING FAN
LIGHT / FAN
TRACK LIGHTING
RECESSED LIGHT FIXTURE
LIGHT FIXTURE
DIMMER SWITCH
4 WAY SWITCH
3 WAY SWITCH
SWITCH
SOFFIT
OUTLET
S
WP
VF
T
SD
TV
R
DM
43
ELECTRICAL SYMBOLS
4030
5080
9060
4030
4030
9060
2868
2868
2668
2668
4068
3068
2468
2668
4068
4068
2668
WH FD
sd
co2
R
RRRRR
R
RR
R
R R
R
R
R R
R
RR
R
R R R R
R R
3
C
3
3
C
3
3 C
C
3
FAMILY14'-4" x 20'-1"
office12'-4" x 13'-5"
media room15'-9" x 20'-1"
BEDROOM11'-11" x 12'-11"
bar area14'-1" x 20'-1"
9'-6"
14'-7 1/2"
4'-0"
3'-8"
5'-7"
1'-0"
4'-3" 5'-5" 4'-3"
1'-6"
47'-7
"
3"
11'-9"
3'-11 3/4"
6'-0"
22'-3 1/2"
15'-0"
22'-2 1/2"
6"
3'-0" 13'-4"
1'-8"
3'-4 3/4"10"
3'-8"
7'-4 1/2"1'-6"
3'-8"
1'-6"
12'-11"2'-11"7'-1"1'-6"
8'-5"
7'-9" 10'-0"
2'-0"
44'-6"
15'-6" 15'-5" 15'-6"3"
15'-2"15'-0"16'-9"7'-7"7'-7"7'-6"7'-6"8'-1"8'-8"
2'-0"
48'-6"
19'-10"
13'-9"
14'-1"
46'-11"
3'-11" 13'-1" 11'-11" 8'-0" 13'-11"50'-10"
6'-0 1/2"
14'-0
"
22'-0
"
12'-0
"
48'-0
"
2'-0"
2'-6"
9'-0
"
2'-6"
2'-0"
18'-0
"
2'-0"2'-
0"
8'-0
"
2'-0"
15'-0"
15'-0"
15'-0"
45'-0"
1'-6"
33'-7
"
14'-0
"
2'-0"
2'-0"
10'-0
"
2'-0"
1'-6"
3'-0"
14'-6" 19'-0"
22'-7"3'-6"3'-0"16'-1"
26'-5"
18'-1"
20'-8"
7'-2"
2'-8"
3'-11"
10'-1"
8'-0" 9'-10" 7'-0" 13'-1" 9'-0"
9'-0"13'-1"10'-10 3/4"13'-11 1/4"
23'-3"
3'-2"
27'-6"
13'-0"
8'-0"
12'-0"
4'-0"
9'-0" 3'-6" 5'-3"
2'-0"
20'-0 3/4"
CANT'L
DN 18R
LINE OF FLOOR ABOVE
6x6 POST ON10" DIA. CONC. COLUMNc/w 4-10mm REBAR@ 6" o/c EACH WAYRUN BARS 3' UP INTO COLUMNMIN. 4' BELOW GRADE(TYP.)
STRUCTURAL STEEL POST(SEE FLOOR JOIST LAYOUT)36"x36"x10" CONC. PADc/w 4 - 10mm REBAR@ 9" o/c EACH WAY(TYP.)
2x10 SPF #2 @
16" O
/C
NOTE:HIGH EFFICIENCY FURNACEAND WATER HEATER
ELECTRICALPANEL LOCATION
ENGINEERED FLOOR JOISTS
HEATING CONTRACTOR TOENSURE FURNACE IS MIN.4'-6" AWAY FROMEXTERIOR WALL
NOTE: MECHANICALLOCATIONS MAY BEALTERED ON SITE
pre-cast conclanding & steps
NOTE: SITE
CONDITIONS MAY
ALTER STAIR.
CONFIRM PRIOR TO
ORDER
note:frost walls to be trenched number & locations of pilestbd ON SITE
garag
e doo
r b
uck
garag
e doo
r b
uck
garag
e doo
r b
uck
garag
e doo
r b
uck
man door buck
man door buck
eng beam by supplier
eng beam by supplier
eng beam by supplier
barrel arch
barrel arch
barrel arch
r=80"
r=3
8"
stackedlaundry
5 sh
bench bench
3
2x10 SPF #2@ 16" O/C
3-2x10 spf#2
carpet
carpet
carpet
carpet
tile
carpet
tile
tile
a/vcabinet
3" conduit
1" u/g conduit
FILE NUMBER 11 057
5
DRAWN: M.S.PCHECKED ---COMPLETED Dec 8 2011
SCALE3/16" = 1'-0"
DRAWING TITLE
THIS DRAWING IS COPYRIGHT AND MUST NOT BEUSED, REPRODUCED, OR REVISED WITHOUTWRITTEN PERMISSION
ALL DIMENSIONS ARE IN FEET AND INCHES UNLESSOTHERWISE NOTED. VERIFY DIMENSIONS.DO NOT SCALE THIS DRAWING
REPORT INCONSISTENCIES AND OMISSIONS TOMODERN DRAFTING & DESIGN FOR CLARIFACTIONBEFORE COMMENCING WITH THE WORK
DEVIATIONS FROM THE CONTRACT DOCUMENTSWITHOUT WRITTEN APPROVAL FROM MODERNDRAFTING & DESIGN ARE SUBJET TO CORRECTIONAT THE CONTRACTORS EXPENSE
IMPERIAL
NO. DATE DESCRIPTION 1.2.3.4.5.
RELEASE/REVISIONS
MAIN FLOOR - 2229 sq. ft.SECOND FLOOR - n/aTOTAL AREA - 2229 sq. ft.BASEMENT - 1876 sq. ft.
FRONT PORCH - 40 sq. ft.REAR DECK - 533 sq. ft.BALCONY - n/aGARAGE - 1683 sq. ft.
SQUARE FOOTAGE
FOUNDATION PLAN
04
GARAGE TO HOUSE WALL CONSTRUCTION
W5 1/2" DRYWALL MUDDED & TAPED2X6 STUDS @ 24" O/CR-20 F.G. BATT INSULATIONLINTELS AS PER CHART OR ENG LAYOUT6MM POLY VAPOUR BARRIER1/2" DRYWALL, MUDDED & TAPED
EXTERIOR WALL CONSTRUCTION
W1 EXTERIOR FINISH AS PER ELEVATIONSBUILDING PAPER3/8" O.S.B. SHEATHING2x6 STUDS @ 24" o/c & 16" o/c @ KIT. CABS.R-20 F.G. BATT INSULATIONLINTELS AS PER CHART OR ENG. LAYOUTFLASHING OVER ALL OPENINGS6mm POLY VAPOUR BARRIER1/2" DRYWALL
W2 (FOR WALKOUT ON 2-STOREY ONLY)SAME CONSTRUCTION AS W1 EXCEPT2x6 STUDS @ 16" o/c
INTERIOR WALL CONSTRUCTION
W3 2x4 OR 2x6 STUDS @ 24" o/c16" o/c @ KIT. CABS.1/2" DRYWALL BOTH SIDES
FOUNDATION WALL CONSTRUCTION
W4 MIN. 6" PARGINGDAMPPROOFING TO GRADE8" CONCRETE WALL1 ROW 10mm REBAR TOP & BOTTOMON 18"x6" CONT. CONCRETE FOOTINGINTERIOR DAMPPROOFING TO GRADE (MIN 4')2x4 STUDS @ 24" o/cR-12 F.G. BATT INSULATION6mm POLY VAPOUR BARRIER
F1 FINISHED FLOORING AS PER SPECIFICATIONS3/4" O.S.B. SUBFLOORENG'D FLOOR JOISTS, SIZED & SPACED BY MANUFACTURER & INSTALLED AS PER MANUFACTURERS SPECIFICATIONS1/2" DRYWALL AS REQUIRED
F2 3" CONCRETE SLAB6mm POLY VAPOUR BARRIER5" COMPACTED GRAVEL
F3 4" CONCRETE SLABSLOPE 4" TO O.H. DOOR10mm REBAR @ 24" o/c EACH WAY5" COMPACTED GRAVEL
FLOOR CONSTRUCTION
C1 F1 CONSTRUCTION6mm POLY VAPOUR BARRIERR-28 F.G. BATT INSULATION3/8" O.S.B.SOFFIT ON EXPOSED AREAS
CANTILEVER CONSTRUCTION
R1 ASPHALT SHINGLESEAVE PROTECTION AS REQUIREDENG'D ROOF TRUSSES @ 24" o/cR-40 F.G. BATT INSULATION6mm POLY VAPOUR BARRIER1/2" DRYWALL
ROOF CONSTRUCTION
1) ALL STRUCTURAL LUMBER IS TO BE #2 SPF OR BETTER.
2) ALL STUDS ARE TO BE CONSTRUCTION GRADE SPF.
3) GENERALLY, EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHINGAND CONCRETE; INTERIOR DIMENSIONS ARE TO FACE OF STUDSAND CENTER OF BEAMS, UNLESS NOTEDOTHERWISE.
4) WALLS LESS THAN 1.2m (4' - 0") FROM PROPERTY LINE ARE TOHAVE A MIN. 45 MINUTE FIRE-RESISTANCE RATING.
5) ENGINEERED ROOF TRUSSES AND FLOOR JOISTS SYSTEMS DESIGNS,DIMENSIONS, DETAILS, INSTALLATIONS, ETC. SHALL BE ACCORDINGTO MANUFACTURES' SPECIFICATIONS AND SHALL BE COMPLETE WITHALL NECESSARY BLOCKING, HANGERS, ETC.
6) ROOF OVERHANGS ARE TO BE 18" UNLESS NOTED OTHERWISE.
7) WHERE STEP FOOTINGS OCCUR, THE HORIZONTAL DIMENSION OFEACH STEP SHALL NOT BE LESS THAN 2'-0" AND THE VERTICALDIMENSION OF EACH STEP SHALL NOT EXCEED 2'-0".
8) ALL FOOTINGS ARE TO BE MIN. 4' BELOW GRADE.
9) CONSTRUCTION SHALL CONFORM TO THE ALBERTA BUILDING CODE& LOCAL BUILDING BYLAWS.
10) WINDOWS & DOOR SIZES ARE READ AS FOLLOWS: 5040 (5'-0" x 4'-0").THESE ARE GENERAL SIZES. ACTUAL SIZES AND ROUGH OPENINGSSHALL BE PROVIDED BY SUPPLIER.
11) ALL PORCHES & DECKS ARE TO BE 3.5" BELOW T.O.S. UNLESS NOTEDOTHERWISE.
12) FINAL LOT GRADES MAY ALTER EXTERIOR APPEARANCE.
GENERAL NOTES
FLOOR ABOVE GARAGE
- INTERIOR FLOOR FINISH- 26/32" STURDI-WOOD- 6 MIL POLY VAPOURBARRIER- ENGINEERED FLOOR JOISTS- DROPPED 2x4 FRAMINGBETWEEN GARAGE ROOF TRUSS ANDWALL- R28 FIBREGLASS BATTINSULATION- 1/2" GYPSUM BOARD
2
10:12
10:12
10:12
10:12
10:12
10:12
10:12
10:12
10:12 10:12 10:12 10:12 10:12
7:12
7:12
7:12
7:12
7:12
7:12
7:12
10:12 10:12
7:12
12
10
12
10
10
12
7
12
12
7
4'-0"
4'-0"
4'-0"
10'-0"
10'-1"
4'-10"
3'-1"
10'-0"
9'-9"
10'-1"
2'-0"
10'-1"
MINIMUM
MINIMUM
WEEPING TILEAS REQUIRED
WEEPING TILEAS REQUIRED
WEEPING TILEAS REQUIRED
18"
18"18"
18"
LINE OF ENTRYROOF INFOREGROUND
UTILITY HALL BEDROOM
MUDROOM
HALL ENTRYDINING
FAMILYOFFICE
BEDROOM
DINING BUTLERPANTRY
KITCHEN / NOOK
GARAGE
ENGINEERED FLOOR JOIST SYSTEM BY SUPPLIER
ENGINEERED ROOF TRUSS SYSTEM BY SUPPLIER
ENGINEERED ROOF TRUSS SYSTEM BY SUPPLIER
ENGINEERED FLOOR JOIST SYSTEM BY SUPPLIER2x10 JOISTS
R=120"
W5
W4
F3
F2
F1
R1
W2
W4
w1
w1
R1
w1
W4
F2
F1
6x6 POST ON10" DIA. CONC. COLUMNc/w 4-10mm REBAR@ 6" o/c EACH WAYRUN BARS 3' UP INTO COLUMNMIN. 4' BELOW GRADE(TYP.)
STRUCTURAL STEEL POST(SEE FLOOR JOIST LAYOUT)36"x36"x10" CONC. PADc/w 4 - 10mm REBAR@ 9" o/c EACH WAY(TYP.)GARAGE NOTE:
ALL GARAGE WALLS & CEILINGTO BE INSULATED, POLY,DRYWALLED & ONE COAT TAPE
NOTE: SITE CONDITIONSMAY ALTER STAIR.CONFIRM PRIOR TO
ORDER
NOTE: SITE CONDITIONSMAY ALTER STAIR.CONFIRM PRIOR TO
ORDER
FILE NUMBER 11 057
5
DRAWN: M.S.PCHECKED ---COMPLETED Dec 8 2011
SCALE3/16" = 1'-0"
DRAWING TITLE
THIS DRAWING IS COPYRIGHT AND MUST NOT BEUSED, REPRODUCED, OR REVISED WITHOUTWRITTEN PERMISSION
ALL DIMENSIONS ARE IN FEET AND INCHES UNLESSOTHERWISE NOTED. VERIFY DIMENSIONS.DO NOT SCALE THIS DRAWING
REPORT INCONSISTENCIES AND OMISSIONS TOMODERN DRAFTING & DESIGN FOR CLARIFACTIONBEFORE COMMENCING WITH THE WORK
DEVIATIONS FROM THE CONTRACT DOCUMENTSWITHOUT WRITTEN APPROVAL FROM MODERNDRAFTING & DESIGN ARE SUBJET TO CORRECTIONAT THE CONTRACTORS EXPENSE
IMPERIAL
NO. DATE DESCRIPTION 1.2.3.4.5.
RELEASE/REVISIONS
MAIN FLOOR - 2229 sq. ft.SECOND FLOOR - n/aTOTAL AREA - 2229 sq. ft.BASEMENT - 1876 sq. ft.
FRONT PORCH - 40 sq. ft.REAR DECK - 533 sq. ft.BALCONY - n/aGARAGE - 1683 sq. ft.
SQUARE FOOTAGE
05
roof layout
crosssection "a"
cross section "b"