36
Industrial Folding Doors and Fire Station Folding Doors Technical Manual: Issue 01.06.2009

Hormann - Steel Folding Doors

Embed Size (px)

Citation preview

Page 1: Hormann - Steel Folding Doors

Industrial Folding Doors and Fire Station Folding DoorsTechnical Manual: Issue 01.06.2009

Page 2: Hormann - Steel Folding Doors

2 Technical Manual: Industrial Folding Doors 06.2009

Reprinting, (even in excerpts) requires our express approval. All rights reserved. All dimensions in mm. Subject to design changes.

Page 3: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 3

Contents

Topic Page

Door selection guide 4

Folding door FSN/FAW (fi nger trap protection) 5

Steel folding door FSN, standard profi le•

Aluminium folding door FAW, with thermal breaks•

FSN/FAW design examples 6

FSN/FAW/FPU/FMI – fl oor details 7

Head details for FSN/FAW, fi tting to the wall, 90° opening, view I – I (see page 5) 8

Head details for FSN/FAW, fi tting in the opening, 90° opening, view I – I (see page 5) 9

Wicket door FSN/FAW 10

Divided traffi c leaf FSN/FAW 11

Folding door FPU/FMI, double-skinned 12

FPU with PUR insulation•

FMI with mineral wool insulation•

Ventilation slots FPU/FMI 13

Head details for FPU/FMI, fi tting to the wall, 90° opening, view D – D (see page 12) 14

Head details for FPU/FMI, fi tting in the opening, 90° opening, view D – D (see page 12) 15

Glazings FPU 16

Glazings FMI 17

Wicket door FPU/FMI 18

Divided traffi c leaf FPU/FMI 19

Sideroom FSN/FAW, view A – A (see page 5) 20

Sideroom FSN/FAW, fi tting to the wall, no passage loss, 90° 21

Sideroom FSN/FAW, fi tting to the wall, no passage loss, 180° 22

Sideroom PU/FMI, view A – A (see page 12) 23

Sideroom FPU/FMI, fi tting to the wall, no passage loss, 90° 24

Sideroom FPU/FMI, fi tting to the wall, no passage loss, 180° 25

Choice of folding arrangements/passage width for 3 and 5-leaf doors, FSN/FAW/FPU/FMI 26

Choice of folding arrangements/passage width for 3 to 12-leaf doors, FSN/FAW/FPU/FMI 27

FSN/FAW/FPU/FMI operator type AFT B900 - folding arrangement 0:2 or 2:0 28

FSN/FAW/FPU/FMI operator type AFT B900 - folding arrangement 2:2 29

Rain canopy/headroom, opening angle 90°, FSN/FAW/FPU/FMI 30

Rain canopy/headroom, opening angle 180°, FSN/FAW/FPU/FMI 31

Fire station folding door FSN/FAW/FPU/FMI, fast opening via a mechanical opening aid 32

Fire station folding door FSN/FAW/FPU/FMI, fast opening via a mechanical opening aid 33

Notes 34

Page 4: Hormann - Steel Folding Doors

4 Technical Manual: Industrial Folding Doors 06.2009

Door Selection Guide

Door typeDepth

approx. 60 mmVersion Sheet thickness/

surface Example leaf infi ll Finger trap protection [KS]

Aluminium diecast hinges, painted black

Thermal insulation value U

Acoustic value R’υ,w,B

4000 x 4000 4000 x 4000

FSN Standard steel profi le

Steel profi le1.5

Sheet steel 1.5 mm

Glazing types between

3 – 36 mm (*)

KS AdjustableFitted on front side

Between 3.5 W/m2 K and

3.7 W/m2 K

Approx. 24 – 28 dB/(A)

FAWAluminium profi le

With thermal breaks

Aluminium profi le2 – 2.5

Insulated glass 26 – 36 mm

PU panel 26 mmKS Adjustable

Fitted on front side

Between 2.0 W/m2 K and

2.3 W/m2 KApprox. 28 dB/(A)

FPU double-skinned

Polyurethane sandwich panel

Stucco-textured or smooth

1.0

Polyurethane(*) KS Surface-

mounted

Between 1.5 W/m2 K and

1.8 W/m2 KApprox. 22 dB/(A)

FMI double-skinned

Mineral wool sandwich panel

Smooth 1.5

(1.75)

Mineral wool (*) KS Surface-

mounted

Between 1.6 W/m2 K and

1.9 W/m2 KApprox. 24 dB/(A)

Glazing types, see the price list *Fire station folding door with folding arrangement 2:2 (see pages 32 – 33)

Size range for manually operated doors

RA

M h

eigh

t

6000

5000

4500

4000

3500

3000

2500

App

rox.

35

00

4000

App

rox.

52

00

App

rox.

80

00

App

rox.

14

000

RAM width

Size range for power-driven doors

RA

M h

eigh

t

6000

5000

4500

4000

3500

3000

2500

App

rox.

35

00

4000

App

rox.

52

00

App

rox.

56

00

App

rox.

80

00

App

rox.

14

000

RAM width

Fully glazed Fire station FPU FMI FSN FAWMax. RAM

4000 x 4000Max. RAM

5200 x 5000Leaf width max. 1400

Leaf width max. 1400

Leaf width max. 1400

Leaf width max. 1300

Page 5: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 5

Steel Folding Door FSN (Standard Profi le) with Finger Trap ProtectionAluminium Folding Door FAW (with thermal breaks) with Finger Trap ProtectionFolding door, 3-leaf version

FAW: View A – A1x trap protection, see page 20

FAW: View B – B2x trap protection

FSN: View A – A1x trap protection

FSN: View B – B2x trap protection

Elastic trap protection profi les on the vertical leaf edges ensure accident-free operation and also reduce noise.

Fitting to the wall

Fixing of the open door leaves via a drop bolt. Wall hold-open device on request.

Note:Do plaster and screed work after door fi tting.• Folding arrangements and clear passage dimensions, see pages 26 – 27.• With/without ventilation slots•

RAM Overall frame dimension =LB Clear width =LDB Clear passage width =FFL Top edge of fi nished fl oor level =

LDB (90°)

LDB (180°)

LB

RAM = LB + 160

EXTERIOR

Folding arrangement 1:2

Traffi c leaf

Tubular guide railTrack roller

Intermediate, adjustable aluminium diecast hinge

FFL

Surface-mounted espagnolette lock with loop handle

Surface-mounted

espagnolette lock, prepared

for profi le cylinder

with lever handle set

View I – ISee pages 8 – 9

Page 6: Hormann - Steel Folding Doors

6 Technical Manual: Industrial Folding Doors 06.2009

FSN/FAW Design Examples

FSN/FAW (max. RAM of the door) FSN

FSN: View K – K FAW: View K – K

Smooth sheet steel Single pane Insulated pane Special infi ll Insulated glass Insulated glass or PU panel

Base area View M – M Base area View N – NView M – M Ventilation slots View N – N Lockable ventilation slots

Max

. 600

0

Min. 1.5 mm

Max. 6 mm

26 mm or 36 mm

Min. 18 mm to max. 36 mm

Min. 26 mm to

max. 36 mm

Max

. 125

0

K

K

M

M

Min

. 300

– m

ax. 6

00

N

N

Min

. 300

– m

ax. 6

00

Min

. 300

– m

ax. 6

00

Min

. 300

– m

ax. 6

00

Optionally with sliding cover on door interior

Max

. 237

5

Max

. 300

0

Max

. 400

0

Max

. 500

0

Fully

gla

zed

(real

gla

ss)

Max

. 400

0

PU panelMax. 26 mm

Page 7: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 7

FSN/FAW/FPU/FMI – Floor Details

Special version with threshold for e.g. fi re station folding doors

15

94

26

130

150

Version without threshold

15

INTERIOR EXTERIOR

FFL

L 120 x 80 x 8

Recess 130 x 150Leave free until after fi tting

FFL

On-site internalwater run-off

INTERIOR EXTERIOR

Page 8: Hormann - Steel Folding Doors

8 Technical Manual: Industrial Folding Doors 06.2009

Head Details for FSN/FAWFitting to the Wall, 90° OpeningView I – I (see page 5)

Sideroom overview, see pages 20 – 2290° headroom overview, see page 30180° headroom overview, see page 31

External fi tting Internal fi tting

135

150

100

26

1550

30 x 68 x 50

20

150

1550

100

135

20

30 x 68 x 50

INTERIOR EXTERIOR

LH =

LD

H

RA

M =

LH

+ 1

06

FFL

Min

. 95

Min

. 60

On-site recess

LH

INTERIOR EXTERIOR

RA

M =

LH

+ 8

0

LDH

= L

H –

26

FFL

Min

. 60

Min

. 95

On-site recess

On-site internal water run-off

Doors on the weather side are preferably fi tted externally!• Threshold required as a guide.• 3 and 4-leaf doors also without a threshold on request• On-site internal water run-off required.•

RAM Overall frame dimension =LH Clear height =LDH Clear passage height =FFL Top edge of fi nished fl oor level =

Page 9: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 9

Head Details for FSN/FAWFitting in the Opening, 90° OpeningView I – I (see page 5)

Sideroom overview, see pages 20 – 2290° headroom overview, see page 30180° headroom overview, see page 31

External fi tting Internal fi tting

150

135

30 x 68 x 50

26

5015

100

15

15

150

135

30 x 68 x 50

26

5015

100

15

15

Doors on the weather side are preferably fi tted externally!• Threshold required as a guide.• 3 and 4-leaf doors also without a threshold on request• On-site internal water run-off required.•

RAM Overall frame dimension =LH Clear height =LDH Clear passage height =FFL Top edge of fi nished fl oor level =

INTERIOR EXTERIORLDH

= L

H -

(20

+ 60

+ 1

5)

LH

Min. 60

RA

M =

LH

+ 2

6 –

15

FFL

Min. 60

On-site recess

LH

FFL

Min. 60

INTERIOR EXTERIOR

RA

M =

LH

– 1

5

LDH

= L

H -

(26

+ 20

+ 6

0 +

15)

Min. 60

On-site internal water run-off

On-site recess

Page 10: Hormann - Steel Folding Doors

10 Technical Manual: Industrial Folding Doors 06.2009

Wicket Door FSN/FAW

Wicket door – View FSN/FAW bottom section height

30

60

30

110110

Note:The wicket door is adjusted to match the appearance of the door version.

LDB Clear passage width =LDH Clear passage height =FFL Top edge of fi nished fl oor level =

LDB (opened by 180°)

Backset 40

FFL

LDH

max

. 250

0

Exterior rain canopy

70 =

rail

60

90 =

rail

80

FFL

1050

from

FFL

Wic

ket d

oor h

eigh

t(n

ote

horiz

onta

l rai

l div

isio

n fo

r the

doo

r lea

f!)

2-piece aluminium hinge, black, screwed

Plastic lever handle set, prepared for profi le cylinder, black

A wicket door must be provided for • folding doors without a traffi c leaf (locking leaf), i.e. those with folding arrangements 2:2, 2:4, 4:4, etc. and without a second entrance.An outward-opening escape door may also be required by the authorities.•

Page 11: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 11

Divided Traffi c Leaf FSN/FAW

Folding door, 3-leaf version, divided traffi c leaf

Detail

FFL Top edge of fi nished fl oor level =

Detail

Traf

fi c le

af h

eigh

t max

. 200

0

Track roller Tubular guide rail

1050

from

FFL

Surface-mounted espagnolette lock with

loop handle

Surface-mounted espagnolette lock,

prepared for profi le cylinder, with lever

handle set

FFL

Divided traffi c leaves (lock leaves) do not have an obstructive threshold rail as with wicket doors.• They are recommended for door heights above 3500 mm and in windy areas (with manual operation).• They also reduce loss of heat.• Divided traffi c leaves enable a larger passage width and barely impair the overall appearance of the door.•

Page 12: Hormann - Steel Folding Doors

12 Technical Manual: Industrial Folding Doors 06.2009

Steel Folding Door FPU/FMI, Double-SkinnedFPU with PUR InsulationFMI with Mineral Wool Insulation

Folding door, 4-leaf version

View A – A1x trap protection, see page 23

View B – B2x trap protection

View C – C1x trap protection

View D – DSee pages 14 – 15

Elastic trap protection profi les on the vertical leaf edges ensure accident-free operation and also reduce noise.

Fitting to the wall

80

Fixing of the open door leaves via a drop bolt. Wall hold-open device on request.

Note:Do plaster and screed work after door fi tting.• Folding arrangements and clear passage dimensions, see • pages 26 – 27.Without ventilation slots• With ventilation slots with/without sliding cover•

RAM Overall frame dimension =LB Clear width =LDB Clear passage width =FFL Top edge of fi nished fl oor level =

A A W W C C

Surface-mounted espagnolette lock with loop handle

Surface-mounted espagnolette lock, prepared for profi le cylinder, with lever handle set

FFL

D

D

Tubular guide rail

Aluminium diecast hinge

1050

from

FFL

Track roller

RAM = LB + 160LB

LDB (180°)

Traffi c leaf

Door leaf stayLDB (90°)

Folding arrangement 1:3EXTERIOR

FPU: Door leaf with PUR insulation approx. 60 mm thick (textured on both sides or smooth sheet steel)FMI: Door leaf with mineral wool insulation approx. 60 mm thick (1.50 mm thick smooth sheet steel on both sides)

Door leaf, guide rail and frame hot galvanized and wet primer-coated.Finger trap protection consisting of a hollow rubber profi le between the individual door leaves and side frame.Top lip seal, bottom brush seal.

Page 13: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 13

Ventilation Slots FPU/FMI

1 ventilation slot group 12 cm2 28 ventilation slots (example) 112 cm2Ventilation slots

Two-side

80

50

30

Exterior ventilation slots Interior sliding cover

Min

. 80

Optionally with sliding cover on

door interior

Min

. 80

Min. 180 Min. 180

Min. 830without glazing

Free ventilation cross section: 3 ventilation slots form one group = 12 cm2, several groups can be arranged next to or on top of each other. Interior sliding cover possible.

Page 14: Hormann - Steel Folding Doors

14 Technical Manual: Industrial Folding Doors 06.2009

Head Details for FPU/FMIFitting to the Wall, 90° View D – D (see page 12)

Sideroom overview, see pages 23 – 2590° headroom overview, see page 30180° headroom overview, see page 31

External fi tting Internal fi tting

30 x 68 x 50

85 x 60

135

15

26

10050

60

150

1520

85 x 60

30 x 68 x 50

15

26

100

50

135

2015

150

With insulation Without

insulation

Doors on the weather side are preferably fi tted externally!• Threshold required as a guide.• 3 and 4-leaf doors also without a threshold on request• On-site internal water run-off required.•

RAM Overall frame dimension =LH Clear height =LDH Clear passage height =FFL Top edge of fi nished fl oor level =

LH =

LD

H

RA

M =

LH

+ 1

06

FFL

Insulation

Min

. 95

Min

. 60

INTERIOR EXTERIOR

On-site recess

LH

Insulation

RA

M =

LH

+ 8

0

LDH

= L

H -

26

FFL

Min

. 60

Min

. 95

On-site internal water run-off

INTERIOR EXTERIOR

On-site recess

Page 15: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 15

Head Details for FPU/FMIFitting in the Opening, 90° Opening View D – D (see page 12)

Sideroom overview, see pages 23 – 2590° headroom overview, see page 30180° headroom overview, see page 31

External fi tting Internal fi tting

30 x 68 x 50

135

15

1515

26

10050

150

85 x 60

30 x 68 x 50

15 15

15

26

100 50

135

150

85 x 60

With insulation Without

insulation

Doors on the weather side are preferably fi tted externally!• Threshold required as a guide.• 3 and 4-leaf doors also without a threshold on request• On-site internal water run-off required.•

RAM Overall frame dimension =LH Clear height =LDH Clear passage height =FFL Top edge of fi nished fl oor level =

LH

Insulation

FFL

RA

M =

LH

– 1

5

LDH

= L

H -

121

On-site internal water run-off

INTERIOR EXTERIOR

On-site recess

Min. 60 Min. 60

LDH

= L

H –

95LH

RA

M =

LH

+ 1

1

FFL

Insulation

INTERIOR EXTERIOR

On-site recess

Min. 60Min. 60

Page 16: Hormann - Steel Folding Doors

16 Technical Manual: Industrial Folding Doors 06.2009

Glazings FPU

Standard Special sizeSingle pane Insulated paneView E – E View F – F

a

a

473523573

773

a a

773

Arrangement of glazing in the partial surface

aa aa

a

a

2000

370

a

Divided traffi c leaf

Leaf section A =Min. 1300 to H = 3000• Min. 1400 to H = 3500• Min. 1500 to H = 4000• Min. 1600 to H = 4500• Min. 1700 to H = 5000•

Black glazing frame as a clamping profi le with clear Duratec synthetic single pane 3 mm or Duratec polycarbonate pane 6 mm or Duratec synthetic double pane 26 mm.

a = • min. surrounding area 180

Min

. 125

0

Max. 6

Glazing frame in rounded version, arrangement of glazing in the partial surfacePlastic as standard, metal on request• Preferably in the standard sizes (clear view 473, 523, 573 mm wide, each 773 mm high, Duratec synthetic double pane 26 mm) including • clear Duratec acrylic double pane or double-moulded pane 20 mmOther single panes from 3 to 6 mm or insulated panes up to 26 mm thick are possible on-site.• Special sizes available up to max. 1250 mm high.•

Min

. 208

Max. 26

Min

. 208

Min

. 208

Page 17: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 17

Glazings FMI

Standard Special sizeSingle paneView G – G

a

a

473523573

773

a a

773

Arrangement of glazing in the entire surfaceInsulated pane

View H – H

aa

2000

370

Divided traffi c leaf

Black glazing frame as a clamping profi le with clear Duratec synthetic single pane 3 mm or Duratec polycarbonate pane 6 mm or Duratec synthetic double pane 26 mm.

a = • min. surrounding area 180

Min

. 108

Min

. 30

0

Min

. 108

min

. 108

Min

. 108

Max. 26

Max. 6

Min

. 125

0

Glazing frame in rounded version, arrangement of glazing in the entire surfacePlastic as standard, metal on request• Preferably in the standard sizes (clear view 473, 523, 573 mm wide, each 773 mm high, Duratec synthetic double pane 26 mm) including • clear Duratec acrylic double pane or double-moulded pane 20 mm.Other single panes from 3 to 6 mm or insulated panes up to 26 mm thick are possible on-site.• Special sizes available up to max. 1250 mm high.•

Page 18: Hormann - Steel Folding Doors

18 Technical Manual: Industrial Folding Doors 06.2009

Wicket Door FPU/FMI

A wicket door with threshold must be provided for • folding doors without a traffi c leaf (locking leaf), i.e. those with folding arrangements 2:2, 2:4, 4:4 etc. and without a second entrance (on request also without a threshold for type FMI with folding arrangments 1:2, 2:1, 2:2). An outward-opening escape door may also be required by the authorities.• With • PUR doors a wicket door can only be included from a door height of 3500 mm, and should usually be fi tted in the door leaf without glazing cut-out.

Wicket door view FPUBottom section height 175

FMIBottom section height 95

40

Note:The wicket door is adjusted to match the appearance of the door version.

LDB Clear passage width =LDH Clear passage height =FFL Top edge of fi nished fl oor level =

Wic

ket d

oor h

eigh

t

FFL

1050

from

FFL

2-piece aluminium hinge, black, screwed

Plastic lever handle set, prepared for profi le cylinder, black

Bot

tom

sec

tion

heig

ht

LDH

max

. 250

0

FFL

LDH

max

. 250

0

FFL

Exterior rain canopy

EPDM seal

Black aluminium edge

Black aluminium edge

EPDM seal

EPDM sealBlack aluminium edge

Backset 65

Min. 175Min. 175 LDB (opened by 180°)

Page 19: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 19

Divided Traffi c Leaf FPU/FMI

Folding door, 3-leaf version, divided traffi c leaf

Detail

FFL Top edge of fi nished fl oor level =

Divided traffi c leaves • (lock leaves) do not have an obstructive threshold rail as with wicket doors.They are recommended for door heights above 3500 mm and in windy areas (with manual operation).• They also reduce loss of heat.• Divided traffi c leaves enable a larger passage width and barely impair the overall appearance of the door.•

Traf

fi c le

af h

eigh

t max

. 200

0

Track roller Tubular guide rail

1050

from

FFL

Surface-mounted espagnolette lock with

loop handle

FFL

Surface-mounted espagnolette lock,

prepared for profi le cylinder, with lever

handle set

Detail

Page 20: Hormann - Steel Folding Doors

20 Technical Manual: Industrial Folding Doors 06.2009

Sideroom FSN/FAWView A – A (see page 5)

Fitting to the wall Fitting to the wallStandard/normal fi xing Side fi xing

85 x 60

90

10 20

7010

8585 x 60

Fitting in the opening Fitting to the wallSide fi xing Free passage width with 180° opening angle

10

85 x 6050

10 85

85 x 60

Head details overview, see page 8 – 9 RAM Overall frame dimension =LB Clear width =

RAM = LB + 220

LBMin. 120

LB

RAM = LB + 120

Min

. 60

LB

RAM = LB – 20

Min

. 60

Min

. 60

RAM = LB + 160

Min. 60

LB

Page 21: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 21

Sideroom FSN/FAWFitting to the WallNo Passage Loss

Folding arrangement 2:1

340 250

Folding arrangement 4:3

560 470

Folding arrangement 5:6 (not possible with FAW)

690 780

Head details overview, see pages 8 – 9Folding arrangement overview, see pages 26 – 27

RAM Overall frame dimension =LB Clear width =

RAM = LB + 590LB

RAM = LB + 1470

LB

RAM = LB + 1030

LB

Page 22: Hormann - Steel Folding Doors

22 Technical Manual: Industrial Folding Doors 06.2009

Sideroom FSN/FAWFitting to the WallNo Passage Loss

Folding arrangement 2:1

275

365

120 120

135

135

Folding arrangement 4:3

605

495

120 120

135

135

Folding arrangement 5:5 (not possible with FAW)

715

120 120

135

135

Head details overview, see pages 8 – 9Folding arrangement overview, see pages 26 – 27

RAM Overall frame dimension =LB Clear width =

RAM = LB + 240

LB

RAM = LB + 240

LB

RAM = LB + 240

LB

Page 23: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 23

Sideroom FPU/FMIView A – A (see page 12)

Fitting to the wall Fitting to the wallStandard/normal fi xing Side fi xing

90

10 20

85 x 60

7010

8585 x 60

Fitting in the opening Fitting to the wallSide fi xing Free passage width with 180° opening angle

10

85 x 60

10 85

70

85 x 60

Head details overview, see pages 14 – 15 RAM Overall frame dimension =LB Clear width =

LB

RAM = LB + 120

Min

. 60

LB

RAM = LB – 20

Min

. 60

Min

. 60

LB

RAM = LB + 260

Min. 140

LB

RAM = LB + 160

Min. 60

Page 24: Hormann - Steel Folding Doors

24 Technical Manual: Industrial Folding Doors 06.2009

Sideroom FPU/FMIFitting to the WallNo Passage Loss

Folding arrangement 2:1

340 250

Folding arrangement 4:3

560 470

Folding arrangement 5:6

690 780

Head details overview, see pages 14 – 15Folding arrangement overview, see pages 26 – 27

RAM Overall frame dimension =LB Clear width =

RAM = LB + 590LB

RAM = LB + 1470LB

RAM = LB + 1030

LB

Page 25: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 25

Sideroom FPU/FMIFitting to the WallNo Passage Loss

Folding arrangement 2:1

275

365

140 140

135

135

Folding arrangement 4:3

495

605

140 140

135

135

Folding arrangement 5:6

140 140

135

715

135

Head details overview, see pages 14 – 15Folding arrangement overview, see pages 26 – 27

RAM Overall frame dimension =LB Clear width =

RAM = LB + 280

LB

RAM = LB + 280

LB

RAM = LB + 280

LB

Page 26: Hormann - Steel Folding Doors

26 Technical Manual: Industrial Folding Doors 06.2009

Folding Arrangement/Passage Widthfor 3 and 5-Leaf DoorsFSN/FAW/FPU/FMI

Folding arrangements are read from the opening side (fi tting side) from left to right. 3 and 4-leaf doors with folding arrangements 3:0, 0:3, 1:3, 3:1, 4:0 and 0:4 without threshold and with internal fi tting with guide piece in the fl oor.

FAWFSN

FPUFMI

➀ Folding doors without a traffi c leaf: A wicket door is required if there is no second entrance.

RAM - 590 RAM - 240 RAM - 280 1:2

RAM - 590 RAM - 240 RAM - 280 2:1

RAM - 565 RAM - 215 RAM - 200 3:00

RAM - 565 RAM - 215 RAM - 200 00:3

RAM - 720 RAM - 240 RAM - 280 1:3

RAM - 720 RAM - 240 RAM - 280 3:1

RAM - 680 RAM - 240 RAM - 280 2:2 ➀

RAM - 655 RAM - 215 RAM - 200 00:4 ➀

RAM - 655 RAM - 215 RAM - 200 4:00 ➀

RAM - 810 RAM - 240 RAM - 280 2:3

RAM - 810 RAM - 240 RAM - 280 3:2

RAM - 810 RAM - 240 RAM - 280 4:1

RAM - 785 RAM - 215 RAM - 200 00:5

Page 27: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 27

Folding Arrangement/Passage Widthfor 6 to 12-Leaf DoorsFSN/FAW/FPU/FMI

Folding arrangements are read from the opening side (fi tting side) from left to right.

FAWFSN

FPUFMI

➀ Folding doors without a traffi c leaf: A wicket door is required if there is no second entrance.➁ Not possible with FAW

RAM - 940 RAM - 240 RAM - 280 3:3

RAM - 940 RAM - 240 RAM - 280 3:3

RAM - 900 RAM - 240 RAM - 280 2:4 ➀

RAM - 1030 RAM - 240 RAM - 280 3:4

RAM - 1030 RAM - 240 RAM - 280 4:3

RAM - 1120 RAM - 240 RAM - 280 4:4 ➀

RAM - 1250 RAM - 240 RAM - 280 4:5 ➁

RAM - 1250 RAM - 240 RAM - 280 5:4 ➁

RAM - 1380 RAM - 240 RAM - 280 5:5 ➁

RAM - 1380 RAM - 240 RAM - 280 5:5 ➁

RAM - 1470 — — 6:5 ➁

RAM - 1470 — — 5:6 ➁

RAM - 1560 — — 6:6 ➀➁

Page 28: Hormann - Steel Folding Doors

28 Technical Manual: Industrial Folding Doors 06.2009

FSN/FAW/FPU/FMIOperator Type AFT B900 – Folding Arrangement 0:2 or 2:0

Folding door with operator

80

330

170

80

RAM Overall frame dimension =LH Clear height =LB Clear width =LDB Clear passage width =LDH Clear passage height =FFL Top edge of fi nished fl oor level =

RA

M

Operator

LH

LDH

= L

H –

app

rox.

95

Operator

FFL

RAM

Folding arrangement 2:0

Opening angle 90°

LDB = LB – approx. 475 (near operator arm)

LB

Approx. 360

Approx. 370

Approx. 110

Page 29: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 29

FSN/FAW/FPU/FMIOperator Type AFT B900 – Folding Arrangement 2:2

Folding door with operator

8080

170

330

330

80170

80

RAM Overall frame dimension =LH Clear height =LB Clear width =LDB Clear passage width =LDH Clear passage height =FFL Top edge of fi nished fl oor level =

FFL

Operator

LH

LDH

= L

H –

app

rox.

95

Operator Operator

1050

RA

M

RAM

Folding arrangement 2:2

Opening angle 90°

LDB = LB – approx. 740 (near operator arm)

LB

Approx. 110Approx. 110

Approx. 360

Approx. 370

Approx. 360

Approx. 370

Page 30: Hormann - Steel Folding Doors

30 Technical Manual: Industrial Folding Doors 06.2009

Rain Canopies/HeadroomOpening Angle 90°FSN/FAW/FPU/FMI

Canopy 1 Canopy 2

8012016

519

0

60

12016

519

0FSN/FPU/FMI: Door with or without operator

Cover 3

12021

027029

5

295

270

210

120

FAW: Door with operator

Rain canopy length: RAM + approx. 100 mm

Type of fi tting Headroom [mm]Without rain canopy With rain canopy

To the interior wall 95 -To the exterior wall 95 200/200 ➁In the opening - on request

In the opening ➂ 160 on requestFire station folding door 170 -

➁ Applies to FSN folding arrangements: 1:2/2:1/2:2/2:3/3:2/2:4/4:2/2:5/5:2➂ Applies to FAW folding arrangements: 1:2/2:1/2:2/2:3/3:2/2:4/4:2/2:5/5:2

Approx. 170

INTERIOR EXTERIOR

➂INTERIOR EXTERIOR

Approx. 270

INTERIOR EXTERIOR

Approx. 270

INTERIOR EXTERIOR

Operator

Operator arm

Approx. 435

Approx. 270

Page 31: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 31

Rain Canopies/HeadroomOpening Angle 180°FSN/FAW/FPU/FMI

Canopy 4

11521

0

27029

5

Canopy 5

80

210

290315

Rain canopy length: RAM + approx. 300 mm

Type of fi tting Headroom [mm]Without rain canopy With rain canopy

On the wall 240 310/330 ➄In the opening 160 -

➄ Applies to folding arrangements: 1:4/4:1/2:4/4:2/1:5/5:1/2:5/5:2/3:4/4:3/4:4/3:5/5:3/4:5/5:4/5:5

INTERIOR EXTERIOR

Approx. 450

INTERIOR EXTERIOR

Approx. 660

Page 32: Hormann - Steel Folding Doors

32 Technical Manual: Industrial Folding Doors 06.2009

Fire Station Folding Doors FSN/FAW/FPU/FMIFast Opening via a MechanicalOpening Aid

Folding arrangement 2:215

20 Without traffi c leaf (locking leaf).Can only be opened from inside (second entrance required).

Fitting to the wall

60 x 85

Mechanical opening aid arranged on the door interior!

Fitting in the opening

RAM Overall frame dimension =LB Clear width =LDB Clear passage width =FFL Top edge of fi nished fl oor level =

DIN 14092 part 2 stipulates doors opening inwards and requires a minimum passage dimension of 3500 mm width and 3500 mm or 4000 mm height. Due to the leaf packs when the door is open, larger opening dimensions may be required, depending on the door, see also folding arrangement 2:2 on page 26. In exceptional cases involving renovations, doors opening outwards are also available, notwithstanding DIN.

FFL

Connecting lead 230 V (3 x 1.5)

On-site connecting lead

Push button

App

rox.

190

0

Grip handle

Energy storing device Snap locking Energy storing device

Lifting magnet 230 V

Grip handlePull cord

Folding arrangement 2:2, opening angle 90°

LDB min. 3500

LB = min 4360

RAM = LB – 20

EXTERIOR

INTERIOR

Fast opening via pre-tensioned opening aids with sound absorber. Folding arrangement 2:2. Opening angle 90°.Release via pull cord. Supplemented with lifting magnet. On-site connecting lead.The quick release can be operated on the left or right (right arrangement shown).The release with pull cord can be supplemented by a lifting magnet and is triggered via a push button.Group switching possible.

RAM = LB + 680 (min. 4180)

LB = LDB (min. 3500)

EXTERIOR

INTERIOR

Space requirement = LB + 800 (min. 4300)

Folding arrangement 2:2, opening angle 90°Min. 170

Min. 850

Page 33: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 33

Fire Station Folding Doors FAW/FPU/FMI/FSNFast Opening via a MechanicalOpening Aid

Fitting to the wall Fitting in the opening

15

1525

140

60x8

560

x85

15

15

1525

120

60x85

60x85

Detail ASeepage 30 120

10

60x8560x85FAWRAM Overall frame dimension =LH Clear height =LDH Clear passage height =FFL Top edge of fi nished fl oor level =

FSN with insulation

FSN without insulation

DIN 14092 part 2 stipulates doors opening inwards and requires a minimum passage dimension of 3500 mm width and 3500 mm or 4000 mm height. Due to the leaf packs when the door is open, larger opening dimensions may be required, depending on the door, see also folding arrangement 2:2 on page 26. In exceptional cases involving renovations, doors opening outwards are also available, notwithstanding DIN.

EXTERIOR INTERIOR

FFL

LH =

cle

ar p

assa

ge h

eigh

t 350

0 or

400

0

RA

M =

LH

+ 1

40

Min

. 60

Min

. 60

Min

. 60

FFL

EXTERIOR INTERIOR

RA

M =

LH

-15

LDH

= L

H –

(160

+ 1

5)

LH =

367

5 or

417

5 w

ith F

AWLH

= 3

670

or 4

170

with

FP

U-F

MI-

FSN

Fast opening via pre-tensioned opening aids with sound absorber. Folding arrangement 2:2. Opening angle 90°.Release via pull cord. Supplemented with lifting magnet. On-site connecting lead.The quick release can be operated on the left or right (right arrangement shown).The release with pull cord can be supplemented by a lifting magnet and is triggered via a push button.Group switching possible.

Page 34: Hormann - Steel Folding Doors

34 Technical Manual: Industrial Folding Doors 06.2009

Notes

Page 35: Hormann - Steel Folding Doors

Technical Manual: Industrial Folding Doors 06.2009 35

Notes

Page 36: Hormann - Steel Folding Doors

Issu

e 06

.200

9 /

Prin

t da

te 0

9.20

09 /

HF

8578

7 en

/ P

.1.5

75

Hörmann KG Werne Hörmann Genk NV, Belgium Hörmann Beijing, China Hörmann LLC, Montgomery IL, USA

Hörmann KG Amshausen Hörmann KG Antriebstechnik Hörmann KG Brandis Hörmann KG Brockhagen

Hörmann KG Dissen Hörmann KG Eckelhausen Hörmann KG Freisen Hörmann KG Ichtershausen

Hörmann: Quality without Compromise

Hörmann is the only manufacturer worldwide that offers you

a complete range of all major building products from one source.

We manufacture in highly-specialized factories using the

latest production technologies.

The close-meshed network of sales and service companies

throughout Europe, and activities in the USA and China,

make Hörmann your strong partner for first-class building

products, offering “Quality without Compromise”.

GARAGE DOORS

OPERATORS

INDUSTRIAL DOORS

LOADING EQUIPMENT

HINGED DOORS

DOOR FRAMES