24
Huawei Network Energy, Powering the Future Huawei Solar Inverter Solution HUAWEI TECHNOLOGIES CO., LTD.

Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

Embed Size (px)

Citation preview

Page 1: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

Huawei Network Energy, Powering the Future

Huawei Solar Inverter Solution

HUAWEI TECHNOLOGIES CO., LTD.

Page 2: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

Corporate InformationHuawei is a leading global ICT solutions provider. Through our dedication to customer-centric innovation and strong partnerships, we have

established end-to-end capabilities and strengths across the carrier networks, enterprise, consumer, and cloud computing fields. We are

committed to creating maximum value for telecom carriers, enterprises and consumers by providing competitive ICT solutions and services.

Our products and solutions have been deployed in over 140 countries, serving more than one third of the world's population.

Huawei's vision is to enrich life through communication. By leveraging our experience and expertise in the ICT sector, we help bridge

the digital divide by providing opportunities to enjoy broadband services, regardless of geographic location. Contributing to the

sustainable development of society, the economy, and the environment, Huawei creates green solutions that enable customers to

reduce power consumption, carbon emissions, and resource costs.

Our Value Propositions Resonating with the revolutionary changes taking place in the information industry, Huawei continuously innovates to meet customer

needs and advance our technology leadership; we openly cooperate with industry partners, focus on building future-proof “Smart

Information Pipes”, and continuously create value for our customers and society at large. Based on these value propositions, Huawei

is dedicated to enriching life and improving efficiency through a better connected world. In addition, we strive to be the first choice

and best partner of telecom carriers and enterprise customers while also becoming a brand of choice among consumers.

Milestones

Founded in 1987, Huawei has grown from a USD 5,680 small company to a global company with a sales volume of over USD 20

billion with business presence in over 140 countries thanks to the tireless efforts of its staff and the company's global-mindedness.

Page 3: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

In more than 20 years, Huawei has provided communication

equipments and stable power supplies for one-third of global

population’s communication service, and has accumulated rich

experience of R&D and application in the ICT and network energy

field. Now Huawei Network Energy has 9 R&D centers and 350

worldwide patents on energy and infrastructure field.

Huawei Solar Inverter is developing rapidly with Network Energy

business together, the inverter R&D team has more than 300

people including over 70% of Masters, 10% of Doctors and 10%

of foreign experts. Adhering to the concept of “high quality,

perfect service, and quick response to customer’s demand", based

on the leading power and digital control technology platform,

Huawei Solar Inverter constantly brings high quality products and

services to the world. As the world's top 500 enterprises, we are

actively promoting the use of clean solar energy by providing a

full range of solar inverters and intelligent monitoring solutions.

Huawei Solar Inverter Research and Development

Shenzhen

Nuremberg

Page 4: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

Huawei

Powering the

EnergyFuture

Page 5: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

Contents

Higher Yields, Never Stop

Huawei Solar Inverter Family

SUN2000 Series

SUN8000 Series

Smart Logger

iManager NetEco Smart Management

High Reliability

Global Service

Page 6: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

1

Higher Yields, Never Stop

High Reliability

With 20 years technology accumulation in telecom power, Huawei builds

inverter product on the same platform. Huawei inverters have passed the

strictest testing above industry level, and approved by the global certification

authorities including TUV.

FriendlySmaller footprint for space saving

Easy to install and maintain with modular design of SUN8000

SUN2000 noise emission≤29dB, equivalent to library environment

SmartLocal graphic LCD screen, easy and comprehensive operation and maintenance.

With Smart Logger and iManager NetEco 1000S, Huawei inverters realize

remote management and grid management.

Higher YieldsHigher yields is the constant pursuit of Huawei Solar Inverter.

With leading topology and control algorithm technology, Huawei inverters have

achieved industry-leading efficiency, and SUN2000-20KTL Photon test result is

A+/A+ at medium and high irradiation with normal silicon devices.

Depend on overload capacity and good performance at low irradiation, as well

as more flexible MPPT, Huawei inverters maximize the power yields.

Page 7: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

2

Huawei Solar Inverter Family

SUN2000

SUN8000

iManager Smart Management

8KTL 10KTL 12KTL 15KTL

SUN8000-500KTL SUN8000-250KTF(2013/Q4)

17KTL 20KTL

Smart Logger iManager NetEco 1000S

Page 8: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

3

SUN2000 Series

SUN20008KTL / 10KTL / 12KTL / 15KTL / 17KTL / 20KTL

SUN2000 maximum efficiency is up to 98.6%, it has good performance at medium and high irradiation, SUN2000-20KTL Photon test

result ranks A+/A+. This series of products supports maximally 3 MPPT for versatile adaption to different module types or quantities

built up with different alignments. Natural cooling technology makes SUN2000 more reliable and the lowest noise emission in

industry of 29 dB, creating really quiet environment for people.

This series of products meets Germany BDEW MV directive and VDE AR N 4105 LV directive, CE Low Voltage Directive and the

Directive for Electromagnetic Compatibility, Italy Enel-GUIDA and CEI 0-21 certification, as well as China Golden Sun certification. It

has good environment adaptability and can be used for various scenarios covering from 8kW to Megawatts, either rooftop or ground

mounted power plants.

A+3/2013

www.photon.info

InternationalThe Solar Power Magazine

98.1 % at high irradiation

Huawei Technologies Sun2000-20KTL

A+3/2013

www.photon.info

InternationalThe Solar Power Magazine

98.0% for medium irradiation

Huawei Technologies Sun2000-20KTL

Page 9: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

4

Efficiency Curve Circuit Diagram

Higher Yields

SUN2000-20KTL Photon test result: A+/A+ at medium and •

high irradiation

Maximum efficiency 98.6% •

European efficiency 98.3% •

Additional harvesting with 10% overload capability •

High Reliability

With 20 years technology accumulation in telecom power, •

the same platform building inverter product

No need of external fan with natural cooling technology •

Type II DC and Type III AC surge protection devices integrated •

Warranty up to 25 years •

Smart

Maximum of 3 MPPT for versatile adaption to different module •

types or quantities built up with different alignments

Up to 6 strings intelligent monitoring and fault detection •

Local graphic LCD and remote monitoring •

RS 485 and USB ports for connectivity and data management •

Friendly

48kg@20KW, compact design of 0.08m • 3

Easy connection with external waterproof DC / AC and •

signal terminals

Noise ≤ 29dB •

Outdoor application of IP65 •

DC SwitchOutput

isolation relay

AC SPDDC SPD

DC-ACconverter

MPPT circuit 2

MPPT circuit 1

Input currentcheck circuit

SUN2000 8KTL/10KTL/12KTL

LC filter

L1L2L3N

PE

OutEMI

Filter

InputEMI

Filter

SUN2000 15KTL/17KTL/20KTL

DC SPD

L1L2L3N

PE

DCSwitch

Outputisolation relay

AC SPD

DC-ACconverter

MPPT circuit 2

MPPT circuit 3

MPPT circuit 1

LC filter

OutEMI

Filter

InputEMI

Filter

Input currentcheck circuit

100.0%

99.0%

98.0%

97.0%

96.0%

95.0%

94.0%

93.0%

92.0%

91.0%

90.0%

0% 20% 40% 60% 80% 100%

99

98

97

96400 620 800

Vmpp

Eu E

ff

Vin=400V97.6% EU97.3%

Vin=620V98.6% EU98.3%

Vin=800V98.3% EU98.0%

Loads

Effic

ienc

y

Page 10: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

5

Technical Specifications

Technical Specifications SUN2000-8KTL SUN2000-10KTL SUN2000-12KTL SUN2000-15KTL SUN2000-17KTL SUN2000-20KTLEfficiency

Max. efficiency 98.5% 98.5% 98.5% 98.6% 98.6% 98.6%

European efficiency 98% 98% 98% 98.3% 98.3% 98.3%

Input

Max. DC input (cosφ=1) 9,100 W 11,400 W 13,700 W 17,100 W 19,200 W 22,500 W

Max. input voltage 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V

Max. input current per MPPT 18 A 18 A 18 A 18 A 18 A 18 A

Min. operating voltage 200 V 200 V 200 V 200 V 200 V 200 V

MPP voltage range 320 V~800 V 320 V~800 V 380 V~800 V 400 V~800 V 400 V~800 V 480 V~800 V

Rated input voltage 620 V 620 V 620 V 620 V 620 V 620 V

Max. number of inputs 4 4 4 6 6 6

Number of MPP trackers 2 2 2 3 3 3

Output

Rated power (230V, 50Hz) 8,000 W 10,000 W 12,000 W 15,000 W 17,000 W 20,000 W

Max. AC output power (cosφ=1) 8,800 W 11,000 W 13,200 W 16,500 W 18,700 W 22,000 W

Rated output voltage3×230V/400V+N+PE 3×220V/380V+N+PE

3×230V/400V+N+PE 3×220V/380V+N+PE

3×230V/400V+N+PE 3×220V/380V+N+PE

3×230V/400V+N+PE 3×220V/380V+N+PE

3×230V/400V+N+PE 3×220V/380V+N+PE

3×230V/400V+N+PE 3×220V/380V+N+PE

AC power frequency 50 Hz/60 Hz 50 Hz/60 Hz 50 Hz/60 Hz 50 Hz/60 Hz 50 Hz/60 Hz 50 Hz/60 Hz

Max. output current 12.8 A 16 A 19.2 A 24 A 27.2 A 32 A

Adjustable power factor0.8 leading ... 0.8 lagging

0.8 leading ... 0.8 lagging

0.8 leading ... 0.8 lagging

0.8 leading ... 0.8 lagging

0.8 leading ... 0.8 lagging

0.8 leading ... 0.8 lagging

Max. total harmonic distortion <3% <3% <3% <3% <3% <3%

Protection

Input-side disconnection device Yes Yes Yes Yes Yes Yes

Anti-Islanding protection Yes Yes Yes Yes Yes Yes

AC over current protection Yes Yes Yes Yes Yes Yes

DC reverse-polarity protection Yes Yes Yes Yes Yes Yes

PV array string fault monitoring Yes Yes Yes Yes Yes Yes

DC surge arresters Type II Type II Type II Type II Type II Type II

AC surge arresters Type III Type III Type III Type III Type III Type III

Insulation monitoring Yes Yes Yes Yes Yes Yes

Residual current detection Yes Yes Yes Yes Yes Yes

Display and Communication

Display Graphic LCD Graphic LCD Graphic LCD Graphic LCD Graphic LCD Graphic LCD

RS485 Yes Yes Yes Yes Yes Yes

USB Yes Yes Yes Yes Yes Yes

General Data

Dimensions(W/H/D)520x610x255 mm (20.5 x 24.0 x 10.0 in.)

520x610x255 mm (20.5 x 24.0 x 10.0 in.)

520x610x255 mm (20.5 x 24.0 x 10.0 in.)

520x610x255 mm (20.5 x 24.0 x 10.0 in.)

520x610x255 mm (20.5 x 24.0 x 10.0 in.)

520x610x255 mm (20.5 x 24.0 x 10.0 in.)

Weight 40 kg 40 kg 40 kg 48 kg 48 kg 48 kg

Operating temperature range-25 °C to +60 °C (-13 °F to +140 °F)

-25 °C to +60 °C (-13 °F to +140 °F)

-25 °C to +60 °C (-13 °F to +140 °F)

-25 °C to +60 °C (-13 °F to +140 °F)

-25 °C to +60 °C (-13 °F to +140 °F)

-25 °C to +60 °C (-13 °F to +140 °F)

Cooling Natural convection Natural convection Natural convection Natural convection Natural convection Natural convection

Operating altitude 3000 m 3000 m 3000 m 3000 m 3000 m 3000 m

Relative humidity (non-condensing)

0~100% 0~100% 0~100% 0~100% 0~100% 0~100%

DC connector Amphenol H4 Amphenol H4 Amphenol H4 Amphenol H4 Amphenol H4 Amphenol H4

AC connector Amphenol C16/3 Amphenol C16/3 Amphenol C16/3 Amphenol C16/3 Amphenol C16/3 Amphenol C16/3

Degree of protection IP65 IP65 IP65 IP65 IP65 IP65

Self-consumption at night < 1 W < 1 W < 1 W < 1 W < 1 W < 1 W

Topology Transformerless Transformerless Transformerless Transformerless Transformerless Transformerless

Noise emission 29dB 29dB 29dB 29dB 29dB 29dB

Warranty5 years10/15/20/25 years optional

5 years10/15/20/25 years optional

5 years10/15/20/25 years optional

5 years10/15/20/25 years optional

5 years10/15/20/25 years optional

5 years10/15/20/25 years optional

Standards Compliance

Safety/EMC EN61000-6-2, EN61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12, EN/IEC62109-1, EN/IEC62109-2

Grid codeVDE-AR-N4105, VDE0126-1-1, BDEW 2008, Enel-Guideline, CEI 0-21, G59/2, G83/1-1, AS4777, CGC/GF004: 2011, IEC61727, IEC62116, RD1669

Page 11: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

6

Dongguan Project 1st Phase 4MW PV Plant SUN2000 global application

Pemfling, Germany Siegen, Germany

Wiesendorf, Germany Shenzhen, STUSC University

Page 12: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

7

SUN8000 Series

SUN8000-500KTL

SUN8000 has leading efficiency up to 98.7% with “T” type three level topology, and significantly improves reliability with modular

design and intelligent dormancy, optimizing efficiency at low irradiation. This product series supports two-winding transformer for

grid-connection with common-mode current rejection algorithm, which helps to save 20% of the transformer investment. SUN8000

is an advanced solution for large-scale PV plant application.

This product series meets Germany BDEW MV directive, CEI 0-16 and China Golden Sun certification, fulfills the requirements of LVRT

and ZVRT. It has passed the strictest verification tests which ensures SUN8000’s good environment adaptability for applications in the

area of high altitude, hot or cold environment.

Page 13: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

8

Efficiency Curve

Circuit Diagram

SUN8000-500KTL100.0%

99.0%

98.0%

97.0%

96.0%

95.0%

94.0%

93.0%

92.0%

91.0%

Vin=620V98.4% EU98.3%

Vin=500V98.7% EU98.5%

Vin=800V98.3% EU98.0%

Loads

Effic

ienc

y

0% 20%10% 30% 50% 70% 90%40% 60% 80% 100%

R

S

T

+-

ACcontactor

+-

DCEMCfilter

DCEMCfilter

ACcircuit

breaker

ACcontactor

ACcircuit

breaker

AC SPD

BranchProtectionModule

BranchProtectionModule

Groundfault

detectionmodule

DC-ACconverter

DC-ACconverter

AC Hallsensor

LC filter circuit

LC filter circuit

AC Hallsensor

SUN8000-500KTL

DC SPD

DC SPD

Tie copper bar

DCHall

sensor

DCdisconnection

switch

DCHall

sensor

DCdisconnection

switch

ACEMCfilter

ACEMCfilter

ACEMCfilter

DCdisconnection

switch

Higher Yields

Maximum efficiency 98.7%, European efficiency 98.5% •

Dynamic system efficiency optimization with intelligent •

dormancy technology

Additional harvesting with 20% overload capacity •

20% saving of medium voltage transformer investment with •

two-winding transformer instead of double-split transformer

Integrated AC&DC power distribution (Optional) •

High Reliability

With 20 years technology accumulation in telecom power, •

the same platform building inverter product

No interruption at single point failure with modular power •

stack design

Grid and self-generating switchable design, 1+1 redundancy •

of system power supply

Redundancy design of key circuits including grid voltage and •

current sampling to improve accuracy and reliability

Smart

Comprehensive local management of system configuration •

and maintenance with LCD touch screen

0~100% active power continuously adjustable and reactive- •

power compensation for grid management

RS485 and USB ports for data transferring and firmware •

update (Security protection mechanism support)

Friendly

Good grid adaptability with LVRT and anti-islanding protection •

High power density, smaller for space saving •

Easy installation and maintenance with modular design •

Optional functions of warming and dehumidification, continuous •

max. power output at the temperature of -30ºC ~ +55ºC

Page 14: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

9

Product Type SUN8000-500KTL

Technical Specifications

Efficiency

Max. efficiency 98.7%

European efficiency 98.5%

Input

Max. input voltage 1000 V

Max. input current 1224 A

Min. operating voltage 475 V

MPP voltage range 500 V~850 V

Max. number of inputs 10

Number of MPP trackers 1~2 (Optional)

Output

Rated power 500 kW/500 kVA

Max. AC output power 600 kW/600 kVA

Rated output voltage 3-phase, 320 V

AC power frequency 50 Hz/60 Hz

Rated output current 900 A

Max. output current 1100 A

Power factor0.8 overexcited … 0.8 underexcited

Max. total harmonic distortion <3%

Standards Compliance

Safety/EMC EN61000-6-2, EN61000-6-4, EN/IEC62109-1, EN/IEC62109-2

Grid code CGC/GF004:2011, Q/GDW 617-2011

Display and Communication

Display Touch screen LCD

RS485 Standard

USB Standard

Ethernet Optional

General Data

Dimensions (W×H×D)1800×2180×650 mm (70.87×85.83×25.59 in.)

Weight 1300 kg

Operating temperature range -30 °C ~ +55 °C (-22 °F to +131 °F)

Cooling Adaptive forced-air cooling

Operating altitude 6000 m (Derating above 3000 m)

Relative humidity(non-condensing) 0~95%

Degree of protection IP20

Topology Transformerless

Protection

Input-side disconnection device Yes

Output-side disconnection protection

Yes

DC / AC over current protection Yes

DC surge arresters Type II

AC surge arresters Type II

Insulation monitoring Yes

Residual current detection Yes

Page 15: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

10

Dongguan Project 1st Phase 4MW PV Plant Jiayuguan 5MW PV Plant

Page 16: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

11

Smart Logger

Smart Logger

Huawei Smart Logger is the data communication center of photovoltaic power system, which can monitor the operating status of up

to 60 photovoltaic power system equipments, and complete data acquisition, data storage, centralized monitor and maintenance.

Stable

Max. reliable communication range •

of 1000 m

10 years data storage with external •

SD card

Smart

3.5 inch. LCD screen •

Web embedded •

Grid management integrated •

Simple

Up to 60 equipments accessible •

Easy to install with wall, tabletop and •

rail mounting

Page 17: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

12

Technical Specifications Smart Logger

Device Management

Max. number of devices 60

Communication interface 3 x RS485

Max. Communication range 1000 m

Display

LCD 3.5 inch. graphic LCD

LED 3 LEDs

Web Embedded Web

General Data

Power supply 100 V~240 VAC, 50 Hz/60 Hz

Power consumption Typ.3 W, max.7 W

Memory 32 MB flash memory, expanded to 16 GB with optional SD card

Language English, Chinese, German, Italian, Spaish, French

Dimensions(W/H/D) 225 mm x 140 mm x 50 mm (8.9 in. x 5.5 in. x 2.0 in.)

Operating temperature range -20ºC to +60ºC (-4ºF to +140ºF)

Relative humidity (non-condensing) 5 - 95%

Degree of protection IP20

Installation options Wall mounting, Tabletop device, Rail mounting

Interface

Ethernet 10 / 100 M, Modbus - TCP

RS485 Modbus - RTU

USB Yes

Number of digital inputs 4

Number of analog inputs 2

Number of Relays 3

Page 18: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

13

iManager NetEcoSmart Management

iManager NetEco 1000S

The system manager and other authorized users can login the iManager NetEco 1000S monitoring system, get the operating data

and alarm information anytime and make remote management. The iManager NetEco 1000S is safe with multi-level access control

right controlled by the system manager.

Stable

Safe with multi-level access control right •

Up to 25 years data storage with CSV file •

Smart

Access anytime and anywhere with •

Internet

Fault alarm with SMS and E-mail •

User-Friendly

Energy flow displaying •

Chart data and information presentation •

Page 19: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

14

iManager Infrastructure

IE

Network

SUN2000 SUN8000 Smart Logger

SUN2000 SUN2000SUN8000 SUN8000Environment monitor

Environment monitor

Smart Logger

RS48S/232

TCP/IP

NetEco 1000S Email, EMS Alarm Grid management center

Page 20: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

15

High Reliability

The Strictest Reliability Test Above Industry Level

HALT HTOL THBThermal Shock

High Temp. & Rain Test

Open Field Exposure

Accelerated lifespan testing to find the shortage of design

-60ºC to 110ºC

5 cycles

Connect to grid in 50ºC with full loading

1000 hours

Max. Temp 85ºC

Humidity 85%-90%

1000 hours

-30ºC to 55ºC

Full loading

5 cycles, 150m/cycle

IP65 testing with high temp. and raining

85ºC

Open field exposure in High temperature, humidity and salt spray

Page 21: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

16

Rocket Triggered Lightning

Test in Conghua City, Guangdong Province, China

Launching rocket into cloud to trigger lightning and testing SUN2000 lightning protection

Test result: SUN2000 worked stably under maximum of 38 kA natural lightning surge current

Page 22: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

17

Global Service

Huawei has professional inverter service engineers all over the world and provides local technical support with rapid response speed.

Huawei provides customized services that include:

7*24 remote support •

Software support •

Active prevention •

Hardware support •

Onsite support •

Others •

GNOC

MSCC

R&D Center

15 MS Regional Centers

Global Customization Centers

Brazil

Kenya

Nigeria

EgyptBahrain

Paksitan

Saudi

Turkey

RomaniaPolandNetherland

Germany

U.S.A.

Mexico

South Latin America

South East Africa

West Africa

North Africa

Central Asia

West Europe

Middle East

China

GNOC, MSCC and R&D Center

ODC, GNOC and MSCC

GNOC

Southeast Asia

IndiaShenzhen

Thailand

South Pacific

Malaysia

North Latin America

North America

Russia

Page 23: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

18

Global R&D Team

Comprehensive reliability activities in the whole process are essential for the stable operation of millions of Huawei power systems in various severe conditions

Huawei Network Energy

Thermal simulation Environment

Stress test

Enhanced conformal coating

EMC Safety Aging testSampling test of thermal shock

Inverter UPS Data Center Infrastructure Site Power Hybrid Power

SUN2000 series string inverter• SUN8000 series central • inverter with transformerSUN8000 series central • inverter without transformer

High power UPS8000 • seriesMedium power UPS5000 • seriesSmall power UPS2000 • series

All-in-one container data center• Cluster container data center• Medium & Large modular data • centerSmall modular data center• Mini modular data center•

Embedded power system• Indoor power system• Outdoor power system• Indoor Site Innovation • SolutionsMini -shelter solution•

PowerCube500• PowerCube1000• PowerCube5000•

Reliability design

Reliability verification

Manufacturing

reliability assurance

NürnbergInverter product development center

StockholmResearch on Power Topology

Beijing

Chengdu

Nanjing

Xi’an UPS and DC

Product Development

Wuhan

Shenzhen Full-series

Energy Product R&D

9 R&D Center

350 Patents

2000+ R&D Engineers, 100+ Doctors, 60%+ Master Degree

10% of sales revenue is used for R&D

ShanghaiInverter product development center

Huaw

ei Netw

orkEnergy Inverter

Page 24: Huawei Network Energy, Powering the Future Huawei …shop.q-cells.com/mediafiles//Sonstiges/HUAWEI_Eng/Huawei Solar... · Huawei Network Energy, Powering the Future Huawei Solar Inverter

Copyright © Huawei Technologies Co., Ltd. 2013. All rights reserved.

No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.

General Disclaimer

The information in this document may contain predictive statements including,

without limitation, statements regarding the future financial and operating results,

future product portfolio, new technology, etc. There are a number of factors

that could cause actual results and developments to differ materially from those

expressed or implied in the predictive statements. Therefore, such information

is provided for reference purpose only and constitutes neither an offer nor an

acceptance. Huawei may change the information at any time without notice.

Trademark Notice

, HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd.

Other trademarks, product, service and company names mentioned are the property of their respective owners.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Industrial Base

Bantian Longgang

Shenzhen 518129, P.R. China

Tel: +86-755-28780808

Version No.: M3-035746-20130522-C-2.0

www.huawei.com