CARLSBAD, CA | PHONE 877 942 1179 | FAX 760 931 2916 | E-MAIL [email protected] | AURORALIGHT.COM In a continuing product improvement program, Auroralight reserves the right to modify product specifications without notification. © 2021 Auroralight, Inc. REV~8.0 (5/2021) TYPE: CAT. #: HWM16-LM- The HWM16-LM Telluride is engineered around Auroralight's Thermally Integrated® Field Serviceable LED Module. Utilizing our Copper Core Technology®, internal temperatures are monitored and self-regulated; this guarantees exceptional performance and long service life. The Telluride includes our Storm Drain™ lens drainage allowing water and dirt to wash away for optimal light transmission. The HWM16 is ideal for up/down lighting and wall grazing outdoor features such as columns, patios, or pergolas. Features include: Interchangeable LED Module in 4, 6, 8 or 12 Watts up to 643 Lumens Delivered 6 Interchangeable PMMA Acrylic Optics 2700K (80 & 90 CRI) or 3000K (80 CRI) Thermally Integrated® w/ Copper Core Technology® Storm Drain™ Lens Drainage System 12V Integral Constant Current Driver (Remote 12V AC/DC Transformer Required) Dimmable to <10% (TRIAC/Forward Phase) via Compatible Transformer Compatible w/ 12V AC/DC MLV or ELV Transformers • Solid Brass Construction HWM16-LM TELLURIDE SEE NEXT PAGE FOR ORDERING INFORMATION TM 6" 152mm 5 1/2" 140mm 4 1/2" 114mm 3 1/2" 89mm 2 1/2" 64mm HWM16-1 w/ 60° Angled Shroud HWM16-1 w/ 90° Straight Shroud HWM16-1 w/ Flush Shroud 7 1/8" 165mm 9" 230mm 10 3/4" 273mm 3 1/2" 89mm 2 1/2" 64mm HWM16-2 w/ 60° Angled Shrouds HWM16-2 w/ 90° Straight Shrouds HWM16-2 w/ Flush Shrouds HWM16-LM-1-90-CP4-BLP HWM16-LM-2-90-CP4-NI The FIT™ IP67 module is built on Auroralight’s Copper Core Technology® platform and includes FIT™ Acrylic Optics. Brass Body Threaded Compression Cap Internal Driver and LEDs UV Resistant Optic

HWM16-LM TELLURIDE

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: HWM16-LM TELLURIDE

CARLSBAD, CA | PHONE 877 942 1179 | FAX 760 931 2916 | E-MAIL [email protected] | AURORALIGHT.COMIn a continuing product improvement program, Auroralight reserves the right to modify product specifications without notification. © 2021 Auroralight, Inc. REV~8.0 (5/2021)

TYPE:CAT. #: HWM16-LM-

The HWM16-LM Telluride is engineered around Auroralight's Thermally Integrated® Field Serviceable LED Module. Utilizing our Copper Core Technology®, internal temperatures are monitored and self-regulated; this guarantees exceptional performance and long service life. The Telluride includes our Storm Drain™ lens drainage allowing water and dirt to wash away for optimal light transmission. The HWM16 is ideal for up/down lighting and wall grazing outdoor features such as columns, patios, or pergolas.

Features include:• Interchangeable LED Module in 4, 6, 8 or 12 Watts up to 643 Lumens Delivered• 6 Interchangeable PMMA Acrylic Optics• 2700K (80 & 90 CRI) or 3000K (80 CRI)• Thermally Integrated® w/ Copper Core Technology®• Storm Drain™ Lens Drainage System• 12V Integral Constant Current Driver (Remote 12V AC/DC Transformer Required)• Dimmable to <10% (TRIAC/Forward Phase) via Compatible Transformer• Compatible w/ 12V AC/DC MLV or ELV Transformers• Solid Brass Construction

HWM16-LM TELLURIDE

SEE NEXT PAGE FOR ORDERING INFORMATION

TM

6"152mm

5 1/2"140mm

4 1/2"114mm

3 1/2"89mm

2 1/2"64mm

HWM16-1 w/ 60° Angled Shroud

HWM16-1 w/ 90° Straight Shroud

HWM16-1 w/ Flush Shroud

7 1/8"165mm

9"230mm

10 3/4"273mm

3 1/2"89mm

2 1/2"64mm

HWM16-2 w/ 60° Angled Shrouds

HWM16-2 w/ 90° Straight Shrouds

HWM16-2 w/ Flush Shrouds

HWM16-LM-1-90-CP4-BLP HWM16-LM-2-90-CP4-NI

The FIT™ IP67 module is built on Auroralight’s Copper Core

Technology® platform and includes FIT™ Acrylic Optics.

Brass Body

Threaded Compression Cap

Internal Driverand LEDs

UV Resistant Optic

Page 2: HWM16-LM TELLURIDE

CARLSBAD, CA | PHONE 877 942 1179 | FAX 760 931 2916 | E-MAIL [email protected] | AURORALIGHT.COMIn a continuing product improvement program, Auroralight reserves the right to modify product specifications without notification. © 2021 Auroralight, Inc. REV~8.0 (5/2021)

TYPE:

HWM16-LM TELLURIDE

ORDERING GUIDE: HWM16-LM H (HIGH PERFORMANCE) WM (WALL MOUNT) 16 (SERIES) L (LED) M (MODULE)Prefix

HWM16-LM

QUICK SPEC SKU HWM16-LM-1-60-8-W-27-H-NAT

INDICATES REQUIRED FIELD INDICATES OPTIONAL FIELD INCLUDED QUICK SPEC (See Below)

ACCESSORIES SELECT UP TO TWO:[H] Hex Baffle[SBH] Stepped Baffle /Hex Baffle Assembly[L] Linear Spread[P] Prismatic Lens[MP] Micro Prismatic[F] Frost (Diffusion)

SHROUD [60] 60° Angled[90] 90° Straight[FS] Flush Shroud

FIXTURE STYLE [1] Single[2] Double

NOTE: Double Fixture Style selection of Shroud, Wattage, Optic and LED Color will apply to both, for differing contact factory

WATTAGE [4] 4W[6] 6W[8] 8W[12] 12W

LED COLOR [27] 2700K, 80 CRI[279] 2700K, 90 CRI[30] 3000K, 80 CRI

NOTE: For other CCT and CRI options, contact factory

OPTIC [N] 20° Narrow[M] 30° Medium[W] 40° Wide[WF] 50° Wide Flood[SF] 60° Super Flood[UF] 75° Ultra Flood[A] All Optics Kit

FINISH

Standard:[NAT] Natural

Plus ($):[BLP] Bronze Living Patina[BLP-XD] BLP Extra Dark

Premium ($$$):[NI] Nickel PVD[PVD] PVD Color (Contact Factory for Color Options)

MOUNT[CP35-BR] 3x5" Brass Cover Plate[CP4-BR] 4" Brass Cover Plate[CP45-BR] 4 1/2" Brass Cover Plate[PC-60-1] 3 ½” Power Canopy Incl. 60W 120-12V Integral Transformer

NOTE: For recessed J-Box, see RJB cut sheet

NOTE: Most common configurations listed above. See product cut sheets for all available options.

MOUNTSACCESSORIES

H SBH L

FP MP CP4 CP45CP35 PC

CAT. #: HWM16-LM-

Page 3: HWM16-LM TELLURIDE

CARLSBAD, CA | PHONE 877 942 1179 | FAX 760 931 2916 | E-MAIL [email protected] | AURORALIGHT.COMIn a continuing product improvement program, Auroralight reserves the right to modify product specifications without notification. © 2021 Auroralight, Inc. REV~8.0 (5/2021)

TYPE:

HWM16-LM TELLURIDE

6 FT 23.5 4.55

10 FT 8.46 7.58

14 FT 4.32 10.6

18 FT 2.61 13.6

22 FT 1.75 16.7

26 FT 1.25 19.7

30 FT 0.940 22.7

Distance From Fixture

Footcandles Beam Width

6 FT 58.3 2.54

10 FT 21.0 4.23

14 FT 10.7 5.92

18 FT 6.48 7.62

22 FT 4.34 9.31

26 FT 3.10 11.0

30 FT 2.33 12.7

Distance From Fixture

Footcandles Beam Width

6 FT 112 1.83

10 FT 40.4 3.04

14 FT 20.6 4.26

18 FT 12.5 5.48

22 FT 8.35 6.70

26 FT 5.98 7.91

30 FT 4.49 9.13

Distance From Fixture

Footcandles Beam Width

6 FT 20.3 4.72

10 FT 7.31 7.87

14 FT 3.73 11.0

18 FT 2.26 14.2

22 FT 1.51 17.3

26 FT 1.08 20.5

30 FT 0.812 23.6

Distance From Fixture

Footcandles Beam Width

PHOTOMETRIC OVERVIEWInformation based on 12W 3000K. To download more in-depth IES photometric data, visit auroralight.com/product/hwm16-lm-telluride/

12W 3000K 60° (WIDE FLOOD)604.3 LUMENS • CBCP 846

AURORALIGHT HSL16-LM-12-WF-30

12W 3000K 25° (MEDIUM)574.1 LUMENS • CBCP 2099AURORALIGHT HSL16-LM-12-M-30

12W 3000K 20° (NARROW)621.4 LUMENS • CBCP 4040AURORALIGHT HSL16-LM-12-N-30

12W 3000K 40° (WIDE)515.0 LUMENS • CBCP 731

AURORALIGHT HSL16-LM-12-W-30

CAT. #: HWM16-LM-