8
PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN APPROVED DATE DRAWING NO. B A C D E F G H 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 DIZON,JOHN JEROME G. ILLUMINATION AND ENGINEERING DESIGN MULTI-STOREY RESIDENTIAL BUILDING POLYTECHNIC UNIVERSITY OF THE PHILIPPINES COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS DATE AUGUST 26,2015 LEGEND P PIN LIGHT LED LED CEILING LIGHTS CEILING FAN W/ LIGHTS FLOURESCENT LAMPS LED SPOT LIGHT H HANGING LAMP GENERAL NOTES MASTERS BEDROOM HOME THEATER FAMILY GALLERY P P P P P P P P P P P P P P P LED LED LED LED LED LED P P P P P P P P P P P P P P P P P P P P P P P P P P P P P LIVING ROOM CAR PARK KITCHEN CR DINING AREA LAUNDRY LED LED LED LED LED LED LED LED P P P P P P P P P P P P P P P 1ST FLOOR LIGHTING LAYOUT 2ND FLOOR LIGHTING LAYOUT H H 1. ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE (PEC). THE RULES AND REGULATION OF THE LOCAL ENFORCING AUTHORITY AND THE REQUIREMENTS OF THE LOCAL POWER COMPANY. THE ELECTRICAL WORKS SHALL BE DONE UNDER THE IMMEDIATE SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER. 2. MATERIALS TO BE USED SHALL BE BRAND NEW AND APPROVED TYPE FOR THE PARTICULAR LOCATION AND PURPOSE OF USAGE. 3. ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE "THW" UNLESS OTHERWISE INDICATED IN THE PLAN. THE MINIMUM SIZE OF WIRE FOR POWER AND LIGHTING CIRCUIT +20(581 6+$// %( PPð $1' ,168/$7(' )25 92/76 60$//(67 5$&(:$< 6+$// %( PP 75$'(120,1$/ 6,=( 4. WIRING METHOD SHALL BE AS FOLLOWS : a. FEEDERS AND RISERS - INTERMEDIATE METALLIC CONDUIT b. LIGHTING, POWER RECEPTACLE - POLYVINYL CHLORIDE CONDUIT SCH. 40 BRANCH CKT., & AUXILIARY 5. GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING AND POWER CIRCUIT AS PER PHILIPPINE ELECTRICAL CODE REQUIREMENT. 18 2.25 2.5 6 1.75 3.75 5.5 4.875 5.625 1.75 3.75 2.5 5.625 4.75 3.625 1.75 3.75 5.25 5.125 1.625 2.375 3.625 1.25 2.25 2.5 3.375 2.25

Illumination Design

Embed Size (px)

DESCRIPTION

Illumination Design of a Residential House

Citation preview

Page 1: Illumination Design

PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN

APPROVED

DATE

DRAWING NO.

BA C D E F G H

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

DIZON,JOHN JEROME G.

ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING

POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING

DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS

DATE AUGUST 26,2015

LEGEND

P PIN LIGHT

LED LED CEILING LIGHTS

CEILING FANW/ LIGHTS

FLOURESCENT LAMPS

LED SPOT LIGHT

H HANGING LAMP

GENERAL NOTES

MASTERSBEDROOM

HOMETHEATER

FAMILYGALLERY

P

P

P

P

P

P

P P

P

P

P

P

P

P

P

LED LED

LED LED

LED

LED

P

P P PP P PP

P

PP P

PP

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

LIVINGROOM

CARPARK

KITCHEN

CR

DININGAREA

LAUNDRY

LED LEDLED LED

LED LEDLED LED

PP

P P

P

P

P

P

P

P

P

P

P

P

P

1ST FLOO

R LIG

HTIN

G LA

YO

UT

2ND

FLOO

R LIG

HTIN

G LA

YO

UT

H

H

1. ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE (PEC).THE RULES AND REGULATION OF THE LOCAL ENFORCINGAUTHORITY AND THE REQUIREMENTS OF THE LOCAL POWERCOMPANY. THE ELECTRICAL WORKS SHALL BE DONE UNDER THE IMMEDIATE SUPERVISION OF A DULY REGISTERED ELECTRICALENGINEER.

2. MATERIALS TO BE USED SHALL BE BRAND NEW AND APPROVED TYPE FOR THE PARTICULAR LOCATION AND PURPOSE OF USAGE.

3. ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATEDTYPE "THW" UNLESS OTHERWISE INDICATED IN THE PLAN. THEMINIMUM SIZE OF WIRE FOR POWER AND LIGHTING CIRCUITHOMERUN SHALL BE 3.5mm² AND INSULATED FOR 600 VOLTS.SMALLEST RACEWAY SHALL BE 15mmØ TRADE/NOMINAL SIZE.

4. WIRING METHOD SHALL BE AS FOLLOWS :a. FEEDERS AND RISERS - INTERMEDIATE METALLIC CONDUITb. LIGHTING, POWER RECEPTACLE - POLYVINYL CHLORIDE CONDUIT SCH. 40 BRANCH CKT., & AUXILIARY

5. GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING AND POWER CIRCUIT AS PER PHILIPPINE ELECTRICAL CODE REQUIREMENT.

18

2.25

2.5

6

1.75

3.75

5.5 4.875

5.625

1.75

3.75

2.55.625

4.75

3.625

1.75

3.75

5.25 5.125

1.625

2.375

3.625

1.25

2.25

2.5

3.3752.25

SuperJhay
Rectangle
SuperJhay
Rectangle
SuperJhay
Typewritten text
1
Page 2: Illumination Design

PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN

APPROVED

DATE

DRAWING NO.

BA C D E F G H

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

DIZON,JOHN JEROME G.

ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING

POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING

DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS

DATE AUGUST 26,2015

MULTI-STOREY RESIDENTIAL BUILDING

SuperJhay
Typewritten text
2
Page 3: Illumination Design

PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN

APPROVED

DATE

DRAWING NO.

BA C D E F G H

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

DIZON,JOHN JEROME G.

ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING

POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING

DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS

DATE AUGUST 26,2015

LIVING ROOM

SuperJhay
Typewritten text
3
Page 4: Illumination Design

PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN

APPROVED

DATE

DRAWING NO.

BA C D E F G H

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

DIZON,JOHN JEROME G.

ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING

POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING

DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS

DATE AUGUST 26,2015

MASTER'S BEDROOM

SuperJhay
Typewritten text
4
Page 5: Illumination Design

PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN

APPROVED

DATE

DRAWING NO.

BA C D E F G H

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

DIZON,JOHN JEROME G.

ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING

POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING

DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS

DATE AUGUST 26,2015

BEDROOM

SuperJhay
Typewritten text
5
Page 6: Illumination Design

PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN

APPROVED

DATE

DRAWING NO.

BA C D E F G H

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

DIZON,JOHN JEROME G.

ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING

POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING

DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS

DATE AUGUST 26,2015

KITCHEN & DINING ROOM

SuperJhay
Typewritten text
6
Page 7: Illumination Design

PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN

APPROVED

DATE

DRAWING NO.

BA C D E F G H

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

DIZON,JOHN JEROME G.

ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING

POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING

DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS

DATE AUGUST 26,2015

HOME THEATER

SuperJhay
Typewritten text
7
Page 8: Illumination Design

PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN

APPROVED

DATE

DRAWING NO.

BA C D E F G H

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

DIZON,JOHN JEROME G.

ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING

POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING

DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS

DATE AUGUST 26,2015

COMFORT ROOM

SuperJhay
Typewritten text
8