Innovations in Cems

Embed Size (px)

Citation preview

  • 8/10/2019 Innovations in Cems

    1/38

    1

    Process Analytic Division

    Revolutionary

    Innovations inContinuous Emissions Monitoring Systems CEMS)

    November 10, 2004

  • 8/10/2019 Innovations in Cems

    2/38

    2

    In t roduct ion

    Continuous Emissions Monitoring Systems(CEMS) are vital in power plant and processindustries.

    These systems traditionally cause facilities to endure

    high installation and maintenance costs. However, revolutionary innovations now present

    significant cost-saving opportunities to CEMS users.

  • 8/10/2019 Innovations in Cems

    3/38

  • 8/10/2019 Innovations in Cems

    4/38

    4

    New Inno vat ive CEMS

    Recent CEMS advancements allow emissionmonitoring accuracy and data handling at asignificantly lower cost than with systems createdfrom discrete components through innovationslike:

    Direct stack/duct enclosure mounting

    Split systems

    Smaller enclosures

    Reduced enclosure power requirements

    Plug and Play Ethernet Web-browser interfaces

  • 8/10/2019 Innovations in Cems

    5/38

    5

    CEMS Designs

    Shelter Approach$150K

    CabinetApproach

    $95K

    Streamlined Field-Mount Approach

    $75K

  • 8/10/2019 Innovations in Cems

    6/38

    6

    Direct Enclosure Moun t ing

    The elimination of a heated sample line between a sample probe and

    a sample conditioning/analysis system can create significant costsavings and save considerable headaches and process downtime orviolations because:

    The installed cost of heated sample lines is about $100 per foot (theaverage 150-foot line costs about $15,000).

    Sample lines are delicate, require skilled installers and are oftendamaged during installation.

    Sample lines require diligent maintenance on the sample probe.

    Process upsets or process equipment failures can sometimes lead toplugging of the sample line, necessitating its replacement.

    Heated sample lines are long lead-time items, often taking weeks toprocure even in emergency situations.

  • 8/10/2019 Innovations in Cems

    7/38

    7

    Direct Enclosure Mounting (cont.) Real-time measurements are important for timely feedback on critical

    emission levels.

    With long sample lines the analysis process is delayed, causingpotentially harmful delays in emission level corrections.

    However, close-coupled or direct mounting of sample handling and

    analysis enclosures eliminates the need for a sample line andprovides the following advantages:

    Reduced transport time for sample reading, providing a near-real-timemeasurement signal

    Faster, continuous measurement for efficient pollution reduction system

    control, quicker adjustments, and reduced emission limits violations Elimination of heated sample lines, providing energy savings as they

    typically use 25-50% of energy consumed by the CEMS

  • 8/10/2019 Innovations in Cems

    8/38

  • 8/10/2019 Innovations in Cems

    9/38

    9

    Spl i t Systems

    Newer CEMS feature a split system architecture of:

    A sample handling system (probe and conditioning station)

    Analysis components

    With sample handling systems mounted on the stack or

    duct, analysis components can be mounted at: Stack

    Base of stack

    Ground level

    Remote buildings

    Other easy to access areas

  • 8/10/2019 Innovations in Cems

    10/38

  • 8/10/2019 Innovations in Cems

    11/38

    11

    All SampleHandling locatedat base of stack

    Probe Only

    Ground Level Ins tal lat ion Opt ional

  • 8/10/2019 Innovations in Cems

    12/38

    12

    Shelterless approach

    Analys is EnclosureIns tallat ion

  • 8/10/2019 Innovations in Cems

    13/38

    13

    Analys is EnclosureIns tallat ion

  • 8/10/2019 Innovations in Cems

    14/38

    14

    Smal ler Enclosu res

    Smaller, self-contained CEMS enclosures provide a

    compact, field-mountable combustion exhaust gasmeasurement system and offer:

    Installation in limited space locations

    Ratings for unprotected outdoor exposure, eliminating the need

    for concrete pad foundations and expensive shelters Compact, efficient cooling/heating control systems to maintain

    constant temperatures

    Reduce/eliminate building maintenance expenses

    Significant energy savings

    Easier, less expensive installation (cranes and other heavy liftingequipment no longer required)

  • 8/10/2019 Innovations in Cems

    15/38

    15

    New Ins tal lat ion Opt ion s

    Smaller system size makes Stainless Steelenclosures more affordable

    Great for EMI/RFI environments

    Meets spec requirements for petrochemical facilities

    Skip the box and HVAC

    2x2 Plate-mount for use in limited space situationson interior walls of existing shelters

    Sample handling enclosure can be mounted onoutside of existing shelters.

  • 8/10/2019 Innovations in Cems

    16/38

    16

    Sample handling directlylocated at the stack

    Unheated sample linesbetween probe andanalyzer/detectors

    Sample Condi t ion ing Enc losu reInstal lat ion

  • 8/10/2019 Innovations in Cems

    17/38

    17

    Sample Condi t ion ing Enc losu reInstal lat ion

  • 8/10/2019 Innovations in Cems

    18/38

    18

    Reduced Enclosu re PowerRequirements

    CEMS users now recognize lower powerrequirements through:

    Significant reduction of heating and cooling coststhrough elimination of shelter.

    Lower power magnitudes than traditional systems(500 Watts versus 30,000 Volt-Amps)

    Elimination of heated sample line power draw (18Watts/foot)

  • 8/10/2019 Innovations in Cems

    19/38

    19

    Use Proven Techno log ies

    New packaging of existing technology

    Benefits of using proven technology:

    Avoid situations where too many changes at one timelimits the diagnosis of root problem

    New packaging is already available using currentlypreferred methods for both sample handling andanalysis.

    Hassles and expenses related to variances or localEPA acceptance of unfamiliar methods are eliminated

  • 8/10/2019 Innovations in Cems

    20/38

    20

    Proven Sample Hand l ing Techno log ies

    Using proven sample handling techniques also eliminates

    costly troubleshooting and maintenance on new technologies,especially since some new packaging options use the sameproven techniques as conventionally packaged systems.

    Unproven techniques may result in higher costs and significant

    lost uptime due to: Learning curves

    Unavailability of trained and experienced service resources

    Limitation on spare parts

    Higher costs for exotic premium technologies

    Slow service response

  • 8/10/2019 Innovations in Cems

    21/38

    21

    Sample Cond i t ion ing Enclosu re w i thProven Techno log ies

    Cal/Purge ValveProbe Connection

    Sample Pump

    Filters

    Thermo Electric

    CoolerPermeation Tube

    AC

    I/O Switch Box

    Power Supply

    Peristaltic Pump

  • 8/10/2019 Innovations in Cems

    22/38

    22

    Proven Sensor Techno log ies

    Eliminate costly diagnostics and maintenance on new

    technologies New packaging options use the same proven techniques as

    conventionally packaged systems

    Use proven EPA Reference Methods

    Proven detectors now available:

    Chemiluminescent NOx

    Nondispersive Infrared (NDIR) CO

    Nondispersive Ultraviolet (NDUV) SO2

    Paramagnetic O2

    Electrochemical O2

  • 8/10/2019 Innovations in Cems

    23/38

    23

    Electronics Section on Bottom

    Physics Section on Top

    Customer I/O Access

    Gas Fitting Connections

    ConstantTemperature

    Control PeltierCooler/Heater

    NEMA 4X Enclosure

    Analys is Enclosu re Design

  • 8/10/2019 Innovations in Cems

    24/38

    24

    PC/104 Controller

    Pocket PC

    23 amp UniversalPower Supply

    Electronics

  • 8/10/2019 Innovations in Cems

    25/38

    25

    Embedded PC

    Choose a system utilizing an industrial computerstandard such as PC-104, as this controllerfeatures:

    Resistance to plant environmental factors such as

    radio frequency interference (RFI), heat and vibration Commercially available parts

    Smaller form factors

    Acceptance as an industrial standard

  • 8/10/2019 Innovations in Cems

    26/38

    26

    Embedded PC (contd)

    Built-in personal computers (PCs) with DASavailable on CEMS models that provide:

    Automatic function controls

    System limit and failure alarms

    Data averaging for regulatory requirements (40 CFR 60)

    Pollution calculations for diluent corrections, mass emissions

    Status flags for all values, calculations, averages.

    Calibration Logs, Alarm Logs, Emissions Logs

    Calibration correction factors for each analyzer output

  • 8/10/2019 Innovations in Cems

    27/38

    27

    Embedded PC (contd)

    Months of data can be stored in the embedded PCs and

    can be:

    256 MB flash drive (no moving parts) can hold 3 months data

    Downloaded via a handheld PC

    Accessed remotely through an Ethernet network Network drive access through Windows Explorer

    Windows drive mapping

    Downloaded in Microsoft Excel or Microsoft Word format forfurther analysis and storage

    Interfaced to DCS, Data Acquisition Systems, etc. through OPCServers

  • 8/10/2019 Innovations in Cems

    28/38

    28

    Handheld PC Operator Interface

    Advanced CEMS feature handheld PCs at theanalysis enclosure that offer:

    Same access as remote web-browser displays

    Drop-down menus that eliminate the need to scroll

    through multiple levels for values or commands Operability outside the enclosure via a cable for more

    comfortable and easier data reading

    Leave it in the enclosure or take it with you

    Password protection, software for CEMS operationsonlyensures the handheld stays with the CEMS

  • 8/10/2019 Innovations in Cems

    29/38

    29

    Operate pocket PCwithout opening

    cabinet

    Connects throughserial port

    External Connect ion for Pocket PC

  • 8/10/2019 Innovations in Cems

    30/38

    30

    Plug and Play Ethernet Web-browser Interface Eliminating the need for custom software drivers to interface

    with plant control systems, CEMS now feature: HTML Web-browser access to operating parameters, system

    setup and process data (Internet Explorer)

    No setup requiredtype IP address once and bookmark!

    Access from any plant computer, home PC, or even from out-of-town corporate offices.

    TCP-IP communications protocol for intranet and Internetcommunications

    Simple message structure for easy programming, parsing by

    OPC Servers, etc. Simple file format allows direct import into spreadsheets and

    database without any modifications or programming

  • 8/10/2019 Innovations in Cems

    31/38

  • 8/10/2019 Innovations in Cems

    32/38

    32

    Time Share Features

    Software configuration of switching time, stacknames, individual calibration parameters for eachstack, etc.

    Automatic status flags for all values, averages,

    calculations, etc. for stack that is in by-pass (I.e.not being sampled)

    Analog output hold for stack in bypass, digitalcontact out to indicate which stack is beingsampled.

  • 8/10/2019 Innovations in Cems

    33/38

    33

    Time Share Option Benefits

    Eliminates the cost of a second set of analyzers

    Great for two stacks for multiple emissions sourceinstallations such as gas turbine plants, auxiliaryboilers, etc.

    Great for before/after SCR control signals

    Great for determining NH3 Slip using before/afterSCR NOx measurement and mass balance formula.

    Perfect for automatic switch-over applications forbackup boilers, bypass stacks, etc.

  • 8/10/2019 Innovations in Cems

    34/38

    34

    Steam Switching Box

    Continuous time-share switching of conditionedsample streams

    Needle valves for flow balancing multiple samplestreams

    Needle valves for flow balancing calibration gases tomultiple sample probes

  • 8/10/2019 Innovations in Cems

    35/38

    35

    Time Share Opt ion Steam Switch ing Box

  • 8/10/2019 Innovations in Cems

    36/38

    36

    Hazardous Area Opt ion s

    Sample Handling and/or Analyzer Enclosure can be upgraded for

    Class 1 Div 2 areas: Z-purge enclosure

    Class 1 Div 2 HVAC units

    Class 1 Div 2 external power supply and cooling fan

    Hazardous area rated junction box Good solution for petrochemical applications where hazardous area

    rated shelters are too big/expensive

    Sample handling enclosure at probe eliminates sample line andassociated hazardous area requirements

    Many stack locations are above the maximum height of the hazardousareaallowing the use of general purpose sample handlingenclosures

  • 8/10/2019 Innovations in Cems

    37/38

    37

    Hazardous Area Enc losures

  • 8/10/2019 Innovations in Cems

    38/38

    38

    Futu re Enhancements

    Additional enhancements are expected in CEMSdevelopment to simplify installation and operatingcosts even more, including:

    NDIR CO2 Bench

    Direct replacement for dilution systems with new low NOxlimits

    Supports new CO2 monitoring and reporting requirements

    Wireless remote access

    Redundant hardware for mission-critical applications