11
Installation Instructions Regolo RXT w/ Flange D/Direct Recessed Mount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2020 Page 1 WARNINGS: •Do not assemble continuous run on the ground and lift into place. Joints will distort and not create a tight fit. Joining hardware will have to be purchased and replaced. •Risk of electrical shock or fire, disconnect power during installation or servicing. Read all instructions completely before starting installation. Install and wire in accordance to all national and local codes by a certifi ed electrician. Fixture may be sharp, handle with care. Let fixture cool before main- tenance. INDIVIDUAL FIXTURES CONTINUOUS ROW FIXTURES AVERTISSEMENTS •Risque d’électrocution ou d’incendie. Déconnectez l’alimenta- tion durant l’installation ou la maintenance. Lisez attentivement toutes les instructions avant de commencer toute installation. Faites installer et câbler selon les normes Nationales et Lo- cales par un électricien certifi é. Les installations peuvent être coupantes, à manipuler avec précaution. Laissez refroidir les installations avant une opération de maintenance. ADVERTENCIA Riesgo de descarga eléctrica oun incendio, desconecte la alimentación durante la instalación o servicio. Leer todas las instrucciones completas antes de empesar la instalación. Instalar y cablear en acuerdo a las reglas nacionales y códigos locales por un electricista certifi cado. El accesorio puede estar agudo, agarre con cuidado deje que el acessorio. Enfriar antes de mantenimiento. DISTORT JOINT

Installation Instructions Regolo RXT w Flange D/Direct...Installation Instructions Regolo RXT w Flange D/Direct Recessed ount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Installation Instructions Regolo RXT w Flange D/Direct...Installation Instructions Regolo RXT w Flange D/Direct Recessed ount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO

Installation InstructionsRegolo RXT w/ Flange

D/DirectRecessed Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2020 Page 1

WARNINGS:•Do not assemble continuous run on the ground and lift into place. Joints will distort and not create a tight fit. Joining hardware will have to be purchased and replaced.

•Risk of electrical shock or fire, disconnect power during installation or servicing. Read all instructions completely before starting installation. Install and wire in accordance to all national and local codes by a certifi ed electrician. Fixture may be sharp, handle with care. Let fixture cool before main-tenance.

INDIVIDUAL FIXTURES CONTINUOUS ROW FIXTURES

AVERTISSEMENTS •Risque d’électrocution ou d’incendie. Déconnectez l’alimenta-tion durant l’installation ou la maintenance. Lisez attentivement toutes les instructions avant de commencer toute installation. Faites installer et câbler selon les normes Nationales et Lo-cales par un électricien certifi é. Les installations peuvent être coupantes, à manipuler avec précaution. Laissez refroidir les installations avant une opération de maintenance.

ADVERTENCIA Riesgo de descarga eléctrica oun incendio, desconecte la alimentación durante la instalación o servicio. Leer todas las instrucciones completas antes de empesar la instalación. Instalar y cablear en acuerdo a las reglas nacionales y códigos locales por un electricista certifi cado. El accesorio puede estar agudo, agarre con cuidado deje que el acessorio. Enfriar antes

de mantenimiento.

DISTORT JOINT

Page 2: Installation Instructions Regolo RXT w Flange D/Direct...Installation Instructions Regolo RXT w Flange D/Direct Recessed ount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO

Installation InstructionsRegolo RXT w/ Flange

D/DirectRecessed Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2020 Page 2

Lighting SyStem ComponentS

*Every luminaire will have an integral driver.

RXT Luminaire Recessed Housing

RXT Luminaire

3’ Power Whip

Wet location J-Box Assembly

Page 3: Installation Instructions Regolo RXT w Flange D/Direct...Installation Instructions Regolo RXT w Flange D/Direct Recessed ount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO

Installation InstructionsRegolo RXT w/ Flange

D/DirectRecessed Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2020 Page 3

Lighting SyStem ComponentS

***Every luminaire will have an integral driver.

Only necessary for continuous rowcomprised of three or more fixtures.

INDIVIDUAL LUMINAIRE CONTINUOUS LUMINAIRE

Row Starter Fixture

Row Mid Fixture

Row End Fixture

Mounting Componentsfor Continuous Fixtures

Power Cable

Compression Spring / Key Stud

Compression Spring / Key Stud

Live EndLive End

Key Hole

Key Hole

Dead End

Dead End

Power Cable

Quik-Connect

Quik-Connect

Quik-Connect

Housing connecting brackets

Fixture stabilizing bracket Quik-Connect

Page 4: Installation Instructions Regolo RXT w Flange D/Direct...Installation Instructions Regolo RXT w Flange D/Direct Recessed ount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO

Installation InstructionsRegolo RXT w/ Flange

D/DirectRecessed Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2020 Page 4

Starter

Mid or End

Sheet Rock / Recessed w/ Flange

Two people are required to install luminaire sections

inStaLLing RXt ReCeSSeD LuminaiReS

Page 5: Installation Instructions Regolo RXT w Flange D/Direct...Installation Instructions Regolo RXT w Flange D/Direct Recessed ount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO

Installation InstructionsRegolo RXT w/ Flange

D/DirectRecessed Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2020 Page 5

LuminaiRe inStaLLation pLanning

Individual

Sheet Rock / Recessed w/ Flange

2’, 3’, 4’, 6’, or 8’

Blocking Wet Location J-Box

Sheet Rock Cut-outFuxtre Length + 5/8” X Fixture width + 5/8”

Mount fixture to blocking through the mounting tabs on the housing sidewalls

Mounting hardware by others

IMPORTANT!NO BLOCKING AT ENDS OF FIXTURE!

IMPORTANT!NO BLOCKING AT ENDS OF FIXTURE!

Fixture Width

4”

Page 6: Installation Instructions Regolo RXT w Flange D/Direct...Installation Instructions Regolo RXT w Flange D/Direct Recessed ount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO

Installation InstructionsRegolo RXT w/ Flange

D/DirectRecessed Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2020 Page 6

inStaLLing an inDiviDuaL oR Row StaRteR LuminaiRe

3

5

4

6

Pull the line power flex from the ceiling through the opening at the end of the fixture

Remove the screws from the j-box cover plate

Attach the flex to the wet location j-box assembly

Seperate the components of the j-box assembly and feed the fixture whip through the bushing, and gasket

1 2

Remove screw from inside of housing to dislodge the j-box assembly

Remove the entire J-box assembly from the housing and set aside

Power end

Power whip from fixture

Page 7: Installation Instructions Regolo RXT w Flange D/Direct...Installation Instructions Regolo RXT w Flange D/Direct Recessed ount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO

Installation InstructionsRegolo RXT w/ Flange

D/DirectRecessed Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2020 Page 7

inStaLLing an inDiviDuaL oR Row StaRteR LuminaiRe

7

9

11

8

10

Make wire connection per local code and reassemble the j-box assembly

Feed the fixture into the housing opening. Tuck the excess power whip above the fixture

The retainer springs will rest on the inside lip of the housing holding it securely in place

Feed the assembled j-box back through the housing opening and secure with the screwm from step 1

Press fixture up into the housing until the retainer spring snap into place

Power whip from fixture

Power whip from fixture

SNAP!

Page 8: Installation Instructions Regolo RXT w Flange D/Direct...Installation Instructions Regolo RXT w Flange D/Direct Recessed ount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO

Installation InstructionsRegolo RXT w/ Flange

D/DirectRecessed Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2020 Page 8

ContinuouS LuminaiRe inStaLLation pLanning

Continuous

Sheet Rock / Recessed w/ Flange

Blocking Wet Location J-Box

Sheet Rock Cut-outCombined Length of Fixtures + 5/8” X Fixture width + 5/8”

Mount fixture to blocking through the mounting tabs on the housing sidewalls

Mounting hardware by others

IMPORTANT!NO BLOCKING AT ENDS OF FIXTURE!

IMPORTANT!NO BLOCKING AT ENDS OF FIXTURE!

Fixture Width

4”

Page 9: Installation Instructions Regolo RXT w Flange D/Direct...Installation Instructions Regolo RXT w Flange D/Direct Recessed ount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO

Installation InstructionsRegolo RXT w/ Flange

D/DirectRecessed Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2020 Page 9

Housing sectionHousing section

Fixture

14

16

12

15

17

13

inStaLLing a Row-miD oR Row-enD (afteR StaRteR haS been inStaLLeD, StepS 1 -11 fRom page 6-7)

Ensure the brackets have created a tight fit to join the sec-tions properly

Install the fixture stabilizing bracket. This bracket is used to stabilize the first fixture while connecting the next fixture.

Locate next housing sectiion in the row and push it into the ceiling cut-out next to the previous housing section

Prepare the first housing section and install the row starter fixture according to steps 1-11 on pages 6 & 7

The stabilizing bracket prevents the fixture from lifting up when installing the next fixture in the row

Install the housing connecting brackets as shown on both sides of the housing

SNAP!

Page 10: Installation Instructions Regolo RXT w Flange D/Direct...Installation Instructions Regolo RXT w Flange D/Direct Recessed ount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO

Installation InstructionsRegolo RXT w/ Flange

D/DirectRecessed Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2020 Page 10

inStaLLing a Row-miD oR Row-enD

Row Starter Fixture installation completed by following steps 1- 17 from pages 6 - 9.

18 19

Connect the male and female quick connector to power the next luminaire in the row

Tuck the wires and connectors into the starter or previous luminaire in the row

Page 11: Installation Instructions Regolo RXT w Flange D/Direct...Installation Instructions Regolo RXT w Flange D/Direct Recessed ount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO

Installation InstructionsRegolo RXT w/ Flange

D/DirectRecessed Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2020 Page 11

22

20

23

21

inStaLLing a Row-miD oR Row-enD (afteR StaRteR haS been inStaLLeD, StepS 1 -17 fRom page 6-9)

Push upward on the new luminaire to secure it to the previous luminaire

Push the luminaires together ensuring proper alignment

The upward motion will tighten the internal compression spring as the luminaires SNAP together for a secure fit

Insert the key stud from the new luminaire into the key hole on the previous luminaire

SNAP!