78
INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English] 1st Edition (Revised 4) 電気製品は、安全のための注意事項を守らないと、 火災や人身事故になることがあります。 このオペレーションマニュアルには、事故を防ぐための重要な注意事項と 製品の取り扱いかたを示してあります。このオペレーションマニュアルを よくお読みのうえ、 製品を安全にお使いください。お読みになったあとは、 いつでも見られるところに必ず保管してください。 IKS-6030M IKS-V6050M IKS-V6050SD IKS-A6050 IKS-V6010M IKS-V6010SD IKS-A6011 IKS-A6012 IKS-A6015 IKS-RS6010 IKS-V6060M IKS-V6060SD IKS-A6061 IKS-A6062 IKS-RS6060 IKS-TC6010 IKS-TC6060

INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

  • Upload
    others

  • View
    18

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

INTEGRATED ROUTING SYSTEM

IXS-6600IXS-6700

OPERATION MANUAL [Japanese/English]

1st Edition (Revised 4)

電気製品は、安全のための注意事項を守らないと、火災や人身事故になることがあります。

このオペレーションマニュアルには、事故を防ぐための重要な注意事項と製品の取り扱いかたを示してあります。このオペレーションマニュアルをよくお読みのうえ、製品を安全にお使いください。お読みになったあとは、いつでも見られるところに必ず保管してください。

IKS-6030M IKS-V6050M IKS-V6050SDIKS-A6050 IKS-V6010M IKS-V6010SDIKS-A6011 IKS-A6012 IKS-A6015IKS-RS6010 IKS-V6060M IKS-V6060SDIKS-A6061 IKS-A6062 IKS-RS6060IKS-TC6010 IKS-TC6060

Page 2: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

2

日本語 JP

安全のために

電気製品は、安全のための注意事項を守らないと、火災や感電などにより死亡や大けがなど人身事故につながることがあり、危険です。事故を防ぐために次のことを必ずお守りください。

安全のための注意事項を守る4 ~ 5 ページの注意事項をよくお読みください。

定期点検を実施する長期間安全に使用していただくために、定期点検を実施することをおすすめします。点検の内容や費用については、ソニーのサービス担当者または営業担当者にご相談ください。

故障したら使用を中止するソニーのサービス担当者、または営業担当者にご連絡ください。

万一、異常が起きたら

m

a 電源を切る。b 電源コードや接続コードを抜く。c ソニーのサービス担当者、または営業担当者に修理を依頼する。

m

すぐに電源を切り、消火する。

異常な音、におい、煙が出たら

炎が出たら

安全のために

警告表示の意味オペレーションマニュアルおよび製品では、次のような表示をしています。表示の内容をよく理解してから本文をお読みください。

この表示の注意事項を守らないと、火災や感電などにより死亡や大けがなど人身事故につながることがあります。

この表示の注意事項を守らないと、感電やその他の事故によりけがをしたり周辺の物品に損害を与えたりすることがあります。

注意を促す記号

行為を禁止する記号

行為を指示する記号

Page 3: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

目次 3

目次

警告 .................................................................................................................................. 4

注意 .................................................................................................................................. 5

その他の安全上のご注意 ........................................................................................................ 5

インテグレーテッド・ルーティングシステムのマニュアル構成 ........................................... 6

概要 ......................................................................................................................................... 6

インテグレーテッド・ルーティングシステム IXS-6600/6700 の特長 ......................... 7

IXS-6600/6700 の商品構成........................................................................................... 8

構成例 ........................................................................................................................ 12

インテグレーテッド・ルーティングシステム IXS-6600/6700 の制御システム ........ 13

インテグレーテッド・ルーティングシステム IXS-6600/6700 の機能 ....................... 13

S-BUS 制御システムの特長 ....................................................................................... 14

システム接続例.......................................................................................................... 15

各部の名称と働き ................................................................................................................. 17

インテグレーテッド・ルーティングシステム IXS-6600............................................ 17

インテグレーテッド・ルーティングシステム IXS-6700............................................ 20

オプション基板.......................................................................................................... 23

ステータス表示 ..................................................................................................................... 26

表示項目 .................................................................................................................... 26

操作ボタンの働き ...................................................................................................... 27

基本操作 .................................................................................................................... 27

機器の状態の確認 ...................................................................................................... 27

表示部のコントラストの調整 .................................................................................... 27

エラー表示と対策 ................................................................................................................. 29

ステータス表示ランプ............................................................................................... 29

エラーステータス ...................................................................................................... 30

付属のソフトウェア.............................................................................................................. 32

BZR-21 のインストール ............................................................................................. 32

主な仕様................................................................................................................................ 33

インテグレーテッド・ルーティングシステム IXS-6700............................................ 33

インテグレーテッド・ルーティングシステム IXS-6600............................................ 34

オプションボード ...................................................................................................... 35

JP

Page 4: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

4

外装を外さない、改造しない外装を外したり、改造したりすると、感電の原因となります。内部の調整や設定および点検を行う必要がある場合は、必ずサービストレーニングを受けた技術者にご依頼ください。

事故を防ぐために、サービストレーニングを受けた技術者以外はサービスを行わない機器内部に手を触れると、感電やけがの原因となります。

内部に水や異物を入れない水や異物が入ると火災や感電の原因となることがあります。万一、水や異物が入ったときは、すぐに電源を切り、電源コードや接続コードを抜いて、ソニーのサービス担当者または営業担当者にご相談ください。

指定の電源コードを使用する指定以外の電源コードを使用すると、火災や感電の原因となります。オペレーションマニュアルの中で指定されている電源コードをお使いください。

電源コードを傷つけない電源コードを傷つけると、火災や感電の原因となります。• 電源コードを加工したり、傷つけたりしない。

• 重いものをのせたり、引っ張ったりしない。

• 熱器具に近づけたり、加熱したりしない。

• 電源コードを抜くときは、必ずプラグを持って抜く。

• ラックマウントするとき、レールにはさみ込まない。万一、電源コードが傷んだら、ソニーのサービス担当者に交換をご依頼ください。

電源コードのプラグおよびコネクターは、突き当たるまでしっかり差し込む電源コードのプラグおよびコネクターを、まっすぐに突き当たるまで差し込まないと、火災や感電の原因となります。

油煙、湯気、湿気、ほこりの多い場所では設置・使用しない上記のような場所で設置・使用すると、火災や感電の原因となります。

2人以上で運搬する本機は重量物ですので、1人で運搬すると腰を痛めたり、けがをすることがあります。

運搬するときは取っ手を持つ(IXS-6700のみ)取っ手以外のところを持って運搬すると、機器が落下してけがの原因となることがあります。

警告

Page 5: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

その他の安全上のご注意

日本国内で使用する電源コードセットは、電気用品安全法で定める基準を満足した承認品が要求されます。ソニー推奨の電源コードセットをご使用ください。

通風孔をふさがない通風孔をふさぐと内部に熱がこもり、火災の原因となることがあります。• 逆さまや横倒しにしない。• 毛足の長い敷物(じゅうたんや布団など)の上に置かない。

• 布をかけない。

安定した場所に設置するぐらついた台の上や傾いたところなどに設置すると、機器が落下してけがの原因となることがあります。

安全アースを接続する安全アースを接続しないと、感電の原因となることがあります。指定された電源コードを使用することで安全アースが接続されます。

ファンが止まったままの状態で使用しないファンが止まると、ステータス表示ランプが赤く点滅します。そのまま使用し続けると、内部に熱がこもり、火災や感電の原因となることがあります。ソニーのサービス担当者にご連絡ください。

電源コード

ご注意

その他の安全上のご注意 5注意 /

Page 6: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

6

インテグレーテッド・ルーティングシステムのマニュアル構成

インテグレーテッド・ルーティングシステムには、以下のマニュアルが用意されています。目的に合わせて、または本書の指示に従ってご覧ください。

オペレーションマニュアル(本書、付属のCD-ROM)インテグレーテッド・ルーティングシステムの簡単な概要、接続例、各部の名称、仕様などの情報を提供します。

システムセットアップマニュアル(付属のCD-ROM)インテグレーテッド・ルーティングシステムの初期設定や動作確認について説明したマニュアルです。本機だけでなく、インテグレーテッド・ルーティングシステムの主要構成機器に関する情報を提供します。

インストレーションマニュアル(付属のCD-ROM)本機の保守に関する情報と、基板交換などの初期サービスに関する情報を提供します。

メンテナンスマニュアル(別売り)部品レベルまでのサービスを前提とした情報(調整要項、マウント図、回路図、詳細なパーツリスト)を提供します。入手を希望される方は、お買い上げいただいた機器の販売担当者にお問い合わせください。

プロトコルマニュアル(別売り)本機を制御するためのプロトコルに関する情報を提供します。本機がサポート可能なプロトコルに対し、次のようなマニュアルが用意されています。必要なプロトコルマニュアルについては、お買い上げいただいた機器の販売担当者にお問い合わせください。S-BUSリモート用ターミナル制御プロトコル:S-BUS PROTOCOL AND COMMAND SPECIFICATIONS

概要

IXS-6600/6700 は、AES/EBUデジタルオーディオ、デジタルビデオ(SDビデオ、HDビデオ)、データ(RS-422A 信号)、タイムコードを扱うインテグレーテッド・ルーティングシステムです。フレームモデルの IXS-6600/6700 に、各種オプション基板を組み合わせて搭載することで、異なる信号を混在させて使用することができます。

◆ 詳しくは、「IXS-6600/6700 の商品構成」(8ページ)をご覧ください。

信号切り換え操作は、別売りのルーティングスイッチャーコントロールユニットBKS-R1617/R1618/R3216/R3219/R3220などの外部制御機器から行います。

◆ 詳しくは、「インテグレーテッド・ルーティングシステム IXS-6600/6700 の制御システム」(13 ページ)をご覧ください。

付属のルーティングスイッチャーリモートコントロールソフトウェアBZR-21 を、イーサネットまたは RS-232C に接続されたPCにインストールすることで、PCからも簡単な信号切り換え操作ができます。

◆ 詳しくは、「付属のソフトウェア」(32 ページ)をご覧ください。

また、本システムを動作させるためには、あらかじめPCのターミナルエミュレーターソフトウェアなどによる各種の設定(テーブルデータ作成やシステムの設定)が必要です。

◆ 詳しくは、付属のシステムセットアップマニュアルをご覧ください。

扱う信号の種類に応じて、使用するオプション基板が異なります。• HDTV SDI 信号を扱う信号系には、入力から出力まですべてHD/SD タイプのオプション基板を使用してください。組み合わせは、以下のとおりです。プロセッサー基板:IKS-V6050M入力基板:IKS-V6010M出力基板:IKS-V6060M

• 出力にHD/SD デジタルビデオアウトプットボードを使用しても、プロセッサー基板が SDTV SDI 信号専用プロセッサー(SDビデオルータープロセッサー)の場合には、HDTV SDI 信号を出力できません。

• RS-422 基板を装着する際、入力基板 IKS-RS6010 と出力基板 IKS-RS6060 をペアで扱うため、入力基板用スロットと出力基板用スロットのスロット番号を同じにする必要があります。たとえば、入力基板を入力基板用スロット 3に装

ご注意

インテグレーテッド・ルーティングシステムのマニュアル構成 / 概要

Page 7: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

着したら、出力基板も出力基板用スロット 3に装着してください。

• 540 Mbps SDTV SDI 信号は、SDデジタルビデオ基板では対応しません。HD/SD対応のデジタルビデオ基板にのみ対応します。

◆ 詳しくは、付属のインストレーションマニュアルをご覧ください。

インテグレーテッド・ルーティングシステム IXS-6600/6700の特長

2種類の筐体より選択可能IXS-6700 は、デジタルビデオ信号の場合 16 入力× 17 出力から最大 128 入力× 136 出力を 8RUの筐体に収納します。IXS-6600 は、16 入力× 17 出力から最大 64 入力× 68 出力を4RUの筐体に収納します。

同一フレームで異なる信号フォーマットに対応IXS-6600/6700 では、以下の信号に対応しています。• ビデオ:HDTV SDI 信号• ビデオ:SDTV SDI 信号• オーディオ:AES/EBUデジタルオーディオ信号• データ:RS-422A 信号• タイムコード:LTC信号ひとつの筐体内で異なる信号フォーマットのボードを同時に動作させることができるため、従来複数台に分けていた筐体を 1台に集約できます。

フレキシブルな入出力構成ビデオ信号は、入力は 16 単位、出力は 17 単位で、それぞれ増設が可能です。デジタルオーディオ信号(バランス)は、入力は 32 単位、出力は 34 単位で、それぞれ増設が可能です。デジタルオーディオ信号(アンバランス)とタイムコード信号(LTC)は、入力は 16 単位、出力は 17 単位で、それぞれ増設が可能です。データ信号は 7入力 /7 出力をペアで扱うため、7入力 /7 出力単位で増設が可能です。

マルチビットレートに対応ビデオ信号は、マルチビットレート対応のオプション基板を使用することで、SDTV SDI 信号(143 Mbps、177 Mbps、270 Mbps、360 Mbps、540 Mbps)およびHDTV SDI 信号(1.485 Gbps、1.485/1.001 Gbps)、DVB-ASI 信号(270 Mbps)に対応します。1入出力単位でこれらの異なるレートに対応できます。

オーディオ信号での非同期システムに対応SRC(サンプリングレートコンバーター)ボードをご使用いただくと、非同期デジタル入力信号にも対応します。

オーディオ信号でビデオの2倍のマトリックスサイズを実現TDM(Time Division Multiplexing:時分割多重)技術で、デジタルオーディオ信号(バランス)は、ビデオ信号に対し、2倍のマトリックスサイズ(256 × 272)を実現しています。

ドルビー E(圧縮オーディオ)に対応

リニアPCMオーディオでサポートしている機能• ソフトスイッチング(V1.10以上)スイッチングポイントでゆるやかにオーディオデータをゼロにすることで、オーディオ成分のポップ音やクリック音を低減します。

ソフトスイッチング機能は、ドルビー Eには対応していません。

• SRC(サンプリングレートコンバーター) ON/OFF 機能サンプリングレートコンバーター機能は、入力信号(AES/EBUデジタルオーディオ)単位でON/OFF を設定できます。

◆ 詳しくは、付属のシステムセットアップマニュアルをご覧ください。

• SRC(サンプリングレートコンバーター)マッチドフェイズモードサンプリングレートコンバーターに入力されたオーディオ信号において、隣接するチャンネル間の位相差を保持する機能です。

同一入力基板内で有効です。複数の入力基板にまたがる信号間では機能しません。

◆ 詳しくは、付属のシステムセットアップマニュアルをご覧ください。

• AES/EBU信号は、ステレオチャンネルです。この 2チャンネルの音源を出す方法として、デフォルトの stereo のほかに Lboth、Rboth、swap、Mix (L+R) があります。(V1.10 以上 )

AES/EBU信号のアンシラリーデータ(チャンネルステータス、ユーザーデータ、バリディティフラグ)に対して、Lboth、Rboth、swap、Mix (L+R) は機能しません。

リニアPCM/圧縮オーディオでサポートしている機能• チャンネルステータスの リジェネレーション(V1.10 以上 )

ご注意

ご注意

ご注意

概要 7

Page 8: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

8

AES/EBU信号を切り換えたとき、ブロック内のデータとCRC(サイクリック・リダンダンシー・チェック)が不整合を起こし、出力次段の機器が CRCエラーなどでミューティングを起こすのを防ぐために、チャンネルステータスのリジェネレーションを行います。

RS-422Aのフィジカルアサインメントに対応

リダンダントCPU/リダンダント電源を標準装備信頼性を重視する放送業務用機器として不可欠なバックアップ用コントロール基板、およびバックアップ用電源ユニットが標準で装備されています。

イーサネットコネクターおよびケーブルの二重化IXS-6600/6700 では、ひとつの筐体に 2つのイーサネットコネクターを装備しています。それぞれに異なる IP アドレスを付加して、ネットワークの二重化をしています。

Web設定(V2.0 以上)1 次局 /2 次局をWebブラウザーから設定できます。

対象機器1 次局:IXS-6600/IXS-6700 (V2.0 以上)2次局:IXS-6600/IXS-6700 (V2.0 以上)、HDS-X5800(対応ブラウザー:Internet Explorer 6)

◆ 詳しくは、付属のシステムセットアップマニュアルをご覧ください。

2系統のリファレンス信号に対応IXS-6600/6700 では、ビデオリファレンス入力をそれぞれ 2系統(A、B)備え、出力のブロック単位で選択できます。たとえば、放送局のハウスシンクと、それと異なる位相/周波数のリファレンスをひとつの筐体内で別々のマトリックスのリファレンスとして使用することができます。

ワードシンク信号に対応オーディオワードシンク信号入力は、IXS-6700 では 2系統、IXS-6600 では 1系統装備されています。

3系統のS-BUSコントロールIXS-6700 には、独立した 3系統 4チャンネル(A、 B1、 B2、C)の S-BUS 用コネクターが装備されています。IXS-6600には独立した 3系統 3チャンネル(A、 B、 C)の S-BUS 用コネクターが装備されています。それぞれ 1本の同軸ケーブルで動作をコントロールできます。

BZR-IF830(4093×4093)コントロールソフトウェアに対応BZR-IF830 をインストールしたルーティングスイッチャーコントローラーHKSP-R80 を、イーサネットおよび S-BUSデータリンクで本機と接続することにより、S-BUS 空間を4093 × 4093 まで拡張できます。拡張された S-BUS 空間内で、複数の S-BUS 空間を制御することもできます。

IXS-6600/6700の商品構成

フレーム

インテグレーテッド・ルーティングシステム IXS-6700IXS-6700 の本体は、EIA 8RUです。ひとつの筐体内で、単一のフォーマットに限定した場合の最大マトリックスサイズは、それぞれ以下のとおりになります。

基本構成は、電源ユニット4台、制御用CPU基板2枚で、それぞれリダンダント構成になっています。以下のオプション基板が装着可能です。

インテグレーテッド・ルーティングシステム IXS-6600IXS-6600 の本体は、EIA 4RUです。ひとつの筐体内で、単一のフォーマットに限定した場合の最大マトリックスサイズは、それぞれ以下のとおりになります。

基本構成は、電源ユニット2台、制御用CPU基板2枚で、それぞれリダンダント構成になっています。以下のオプション基板が装着可能です。

マトリックスボード(オプション)

マトリックスボード IKS-6030M128 入力× 68 出力のマトリックス基板です。IXS-6700 への最大装着枚数は 2枚で、最大 128 入力× 136出力まで拡張できます。IXS-6600 に装着した場合は、64 入力× 68 出力になります。

信号 最大マトリックスサイズ

ビデオ 128 入力× 136 出力

AES/EBU デジタルオーディオ信号(バランス)

256 入力× 272 出力

AES/EBU デジタルオーディオ信号(アンバランス)

128 入力× 136 出力

タイムコード(アンバランス) 128 入力× 136 出力

RS-422A 112 ポート

信号 最大マトリックスサイズ

ビデオ 64入力× 68 出力

AES/EBU デジタルオーディオ信号( バランス)

128 入力× 136 出力

AES/EBU デジタルオーディオ信号(アンバランス)

64入力× 68 出力

タイムコード(アンバランス) 64入力× 68 出力

RS-422A 56 ポート

概要

Page 9: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

オーディオ信号を取り扱う場合は、IXS-6700 では最大 256入力× 272 出力、IXS-6600 では最大 128 入力× 136 出力です。

メインプロセッサーボード(オプション)メインプロセッサーボードとしては、以下の 3種類の基板があります。これらの基板を組み合わせて搭載できます。• HD/SD ビデオルータープロセッサーボード IKS-V6050M• SDビデオルータープロセッサーボード IKS-V6050SD• オーディオ /データルータープロセッサーボード IKS-A6050

HD/SDビデオルータープロセッサーボード IKS-V6050M34 系統のHD/SD デジタルビデオ信号を扱うルータープロセッサーです。SDTV SDI 信号レート(143 Mbps、177 Mbps、270 Mbps、360 Mbps、540 Mbps)、HDTV SDI 信号レート(1.485 Gbps、1.485/1.001 Gbps)、DVB-ASI 規格の信号(270 Mbps)に対応します。1枚のHD/SD ビデオルータープロセッサーボードの後段には、出力基板を最大 2枚まで装着できます。IXS-6700 では、HD/SD ビデオルータープロセッサーボードを 4枚装着すると、136 系統のビデオ信号を出力できます。IXS-6600 では、HD/SD ビデオルータープロセッサーボードを 2枚装着すると、68 系統のビデオ信号を出力できます。出力基板には、HD/SD デジタルビデオアウトプットボード、SDデジタルビデオアウトプットボードとタイムコードアウトプットボードを混在させて使用することができます。

出力基板にHD/SDデジタルビデオアウトプットボードを使用しないと、HDTV SDI 信号は出力できません。

SDビデオルータープロセッサーボード IKS-V6050SD34 系統の SDデジタルビデオ信号を扱うルータープロセッサーです。SDTV SDI 信号レート(143 Mbps、177 Mbps、270 Mbps、360 Mbps)、DVB-ASI 規格の信号(270 Mbps)に対応します。

1枚の SDビデオルータープロセッサーボードの後段には、デジタルビデオ信号アウトプットボードまたはタイムコードアウトプットボードを最大 2枚まで装着できます。IXS-6700 では、SDビデオルータープロセッサーボードを 4枚装着すると、136 系統のビデオ信号を出力できます。IXS-6600 では、SDビデオルータープロセッサーボードを 2枚装着すると、68 系統のビデオ信号を出力できます。

出力基板にHD/SD デジタルビデオアウトプットボードを使用しても、HDTV SDI 信号は出力できません。

オーディオ/データルータープロセッサーボードIKS-A605068 系統のAES/EBUオーディオ信号と 28 系統のデータ信号(RS-422A)、34 系統のタイムコード信号を扱うルータープロセッサー基板です。1枚のオーディオ /データルータープロセッサーボードの後段には、出力基板を最大2枚まで装着できます。出力基板には、AES/EBUオーディオアウトプットボード、RS-422A アウトプットボードとタイムコードアウトプットボードを混在させて使用することができます。

インプットボード(オプション)

16 HD/SD デジタルビデオインプットボードIKS-V6010M16 系統のHD/SD デジタルビデオ信号を扱う入力基板です。入力端子は、SDTV SDI 信号レート(143 Mbps、177 Mbps、270 Mbps、360 Mbps、540 Mbps)、HDTV SDI 信号レート(1.485 Gbps、1.485/1.001 Gbps)、DVB-ASI 規格の信号(270 Mbps)に対応します。IXS-6700 は 16 単位で、16 入力から最大 128 入力まで拡張できます。

オプション型名 商品名最大装着枚数

IXS-6600 IXS-6700

IKS-6030M マトリックスボード 1 2

オプション型名 商品名最大装着枚数

IXS-6600 IXS-6700

IKS-V6050M HD/SD ビデオルータープロセッサーボード

2 4

IKS-V6050SD SD ビデオルータープロセッサーボード

IKS-A6050 オーディオ /データ ルータープロセッサーボード

ご注意

ご注意

オプション型名 商品名最大装着枚数

IXS-6600 IXS-6700

IKS-V6010M 16 HD/SD デジタルビデオインプットボード

4 8

IKS-V6010SD 16 SD デジタルビデオインプットボード

IKS-A6011 32 D-sub AES/EBU(バランス)インプットボード

IKS-A6012 16 BNC AES/EBU(アンバランス)インプットボード

IKS-A6015 32 サンプリングレートコンバーターボード

IKS-RS6010 7 RS-422 インプットボード

IKS-TC6010 16 タイムコードインプットボード

概要 9

Page 10: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

10

IXS-6600 は 16 単位で、16 入力から最大 64 入力まで拡張できます。

16 SD デジタルビデオインプットボード IKS-V6010SD 16 系統の SDデジタルビデオ信号を扱う入力基板です。入力端子は、SDTV SDI 信号レート(143 Mbps、177 Mbps、270 Mbps、360 Mbps)、DVB-ASI 規格の信号(270 Mbps)に対応します。IXS-6700 は 16 単位で、16 入力から最大 128 入力まで拡張できます。IXS-6600 は 16 単位で、16 入力から最大 64 入力まで拡張できます。

IKS-V6010SD は、540 Mbps SDTV SDI 信号レートには対応しません。

32 D-sub AES/EBUインプットボード IKS-A601132 系統のAES/EBUオーディオ信号(バランス)を扱う入力基板です。本機のリファレンス用ワードシンク信号に同期した 48 kHz のサンプリング周波数に対応しています。IXS-6700 では、32 単位で、32 入力から最大 256 入力まで拡張できます。IXS-6600 では、32 単位で、32 入力から最大 128 入力まで拡張できます。

AES/EBUデジタルオーディオインプットボードは、非同期のAES/EBU信号には対応しません。非同期のAES/EBU信号を扱う場合は、32 サンプリングレートコンバーターボード IKS-A6015 と合わせてお使いください。

16 BNC AES/EBUインプットボード IKS-A601216 系統のAES/EBUオーディオ信号(アンバランス)を扱う入力基板です。本機のリファレンス用ワードシンク信号に同期した 48 kHz のサンプリング周波数に対応しています。IXS-6700 は 16 単位で、16 入力から最大 128 入力まで拡張できます。IXS-6600 は 16 単位で、16 入力から最大 64 入力まで拡張できます。

AES/EBUデジタルオーディオインプットボードは、非同期のAES/EBU信号には対応しません。非同期のAES/EBU信号を扱う場合は、32 サンプリングレートコンバーターボード IKS-A6015 と合わせてお使いください。

32 サンプリングレートコンバーターボード IKS-A601532 系統のサンプリングレートコンバーターを扱う基板です。この基板を 32 D-sub AES/EBUインプットボード IKS-A6011 または 16 BNC AES/EBUインプットボード IKS-

A6012 に搭載することで、非同期デジタル入力信号に対応します。

7 RS-422インプットボード IKS-RS60107 系統のデータ信号(RS-422A)を扱う入力基板です。38.4 kbps にのみ対応します。RS-422 基板は、入力基板と出力基板をペアで扱うため、7入力/7出力単位で増設できます。IXS-6700 は 112 ポートまで、IXS-6600 は 56 ポートまで拡張できます。

RS-422 インプットボードと RS-422 アウトプットボードは必ずペアでご使用ください。RS-422 基板(入力基板 IKS-RS6010 と出力基板 IKS-RS6060)を装着する場合、入力基板用スロットと出力基板用スロットのスロット番号を同じにする必要があります。たとえば、入力基板を入力基板用スロット 3に装着したら、出力基板も出力基板用スロット 3に装着してください。

◆ 詳しくは、付属のインストレーションマニュアルをご覧ください。

16 タイムコードインプットボード IKS-TC601016 系統のタイムコード信号(LTC)を扱う入力基板です。IXS-6700 は 16 単位で、16 入力から最大 128 入力まで拡張できます。IXS-6600 は 16 単位で、16 入力から最大 64 入力まで拡張できます。

アウトプットボード(オプション)

17 HD/SD デジタルビデオアウトプットボードIKS-V6060M17 系統のHD/SD デジタルビデオ信号を扱う出力基板です。SDTV SDI 信号レート(143 Mbps、177 Mbps、270 Mbps、360 Mbps、540 Mbps)、HDTV SDI 信号レート(1.485

ご注意

ご注意

ご注意

ご注意

オプション型名

商品名最大装着枚数

IXS-6600 IXS-6700

IKS-V6060M 17 HD/SD デジタルビデオアウトプットボード

4 8

IKS-V6060SD 17 SD デジタルビデオアウトプットボード

IKS-A6061 34 D-sub AES/EBU(バランス)アウトプットボード

IKS-A6062 17 BNC AES/EBU(アンバランス)アウトプットボード

IKS-RS6060 7 RS-422 アウトプットボード

IKS-TC6060 17 タイムコードアウトプットボード

概要

Page 11: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

Gbps、1.485/1.001 Gbps)、DVB-ASI 規格の信号(270 Mbps)に対応します。IXS-6700 は 17 単位で、17 出力から最大 136 出力まで拡張できます。IXS-6600 は 17 単位で、17 出力から最大 68 出力まで拡張できます。

17 SD デジタルビデオアウトプットボードIKS-V6060SD17 系統の SDデジタルビデオ信号を扱う出力基板です。SDTV SDI 信号レート(143 Mbps、177 Mbps、270 Mbps、360 Mbps)、DVB-ASI 規格の信号(270 Mbps)に対応します。IXS-6700 は 17 単位で、17 出力から最大 136 出力まで拡張できます。IXS-6600 は 17 単位で、17 出力から最大 68 出力まで拡張できます。

IKS-V6060SD は、SDTV SDI 信号レート(540 Mbps)には対応しません。

34 D-sub AES/EBUアウトプットボード IKS-A606134 系統のAES/EBUオーディオ信号(バランス)を扱う出力基板です。リファレンス用ワードシンク信号に同期した48 kHz のサンプリング周波数に対応します。IXS-6700 は 34 単位で、34 出力から最大 272 出力まで拡張できます。IXS-6600 は 34 単位で、34 出力から最大 136 出力まで拡張できます。

17 BNC AES/EBUアウトプットボード IKS-A606217 系統のAES/EBUオーディオ信号(アンバランス)を扱う出力基板です。リファレンス用ワードシンク信号に同期した 48 kHz のサンプリング周波数に対応します。IXS-6700 は 17 単位で、17 出力から最大 136 出力まで拡張できます。IXS-6600 は 17 単位で、17 出力から最大 68 出力まで拡張できます。

7 RS-422アウトプットボード IKS-RS60607 系統のデータ信号(RS-422A)を扱う出力基板です。38.4 kbps にのみ対応します。RS-422 基板は、入力基板と出力基板をペアで扱うため、7入力 /7出力単位で増設できます。IXS-6700 は 112 ポートまで、IXS-6600 は 56 ポートまで拡張できます。

RS-422 インプットボードとRS-422 アウトプットボードは必ずペアでご使用ください。RS-422 基板(入力基板 IKS-RS6010 と出力基板 IKS-RS6060)を装着する場合、入力基板用スロットと出力基板用スロットのスロット番号を同じにす

る必要があります。たとえば、入力基板を入力基板用スロット 3に装着したら、出力基板も出力基板用スロット 3に装着してください。

◆ 詳しくは、付属のインストレーションマニュアルをご覧ください。

17タイムコードアウトプットボード IKS-TC606017 系統のタイムコード信号(LTC)を扱う出力基板です。IXS-6700 は 17 単位で、17 出力から最大 136 出力まで拡張できます。IXS-6600 は 17 単位で、17 出力から最大 68 出力まで拡張できます。IKS-A6050、IKS-V6050M、IKS-V6050SDいずれのプロセッサーボードとも組み合わせて使用することができます。

ご注意

ご注意

概要 11

Page 12: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

12

構成例

IXS-6600のハイブリッド構成例

上記のように構成することで、異なる信号フォーマットにそれぞれ対応する複数ルーティングスイッチャーを筐体内に同時に構成することができます。それぞれのフォーマットに対するクロスポイントのサイズは次表のとおりです。

IXS-6700のハイブリッド構成例

17

17

34

7

16 16 32 7

マトリックスボード128 × 68

HD/SDビデオルータープロセッサーボード

17 HD/SDデジタルビデオアウトプットボード

オーディオ /データルータープロセッサーボード

16 HD/SDデジタルビデオ

インプットボード

16 SDデジタルビデオ

インプットボード

32 D-sub AES/EBU

(バランス)インプットボード

7 RS-422インプットボード

17 SD デジタルビデオアウトプットボード

34 D-sub AES/EBU(バランス)アウトプットボード7 RS-422アウトプットボード

マザーボード

商品名

入力端子数

出力端子数 商品名

信号フォーマット マトリックスサイズ

SDI ルーター部 32 × 34(うち HD SDI は 16 × 17)

デジタルオーディオルーター部 32 × 34

RS-422A ルーター部 14 ポート

16

17

17

17

17

34

34

7

7

16 16 16 32 32 7 7

マトリックスボード128× 68

HD/SD ビデオルータープロセッサーボード

オーディオ /データルータープロセッサーボード

17 HD/SDデジタルビデオアウトプットボード

SDビデオルータープロセッサーボード

オーディオ /データルータープロセッサーボード

マトリックスボード128× 68

16 HD/SDデジタルビデオ

インプットボード

16 SDデジタルビデオ

インプットボード

32 D-sub AES/EBU

(バランス)インプットボード

7 RS-422インプットボード

17 SD デジタルビデオアウトプットボード

34 D-sub AES/EBU(バランス)アウトプットボード

7 RS-422アウトプットボード

商品名

入力端子数

出力端子数 商品名マザーボード

概要

Page 13: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

前記のように構成することで、異なる信号フォーマットにそれぞれ対応する複数ルーティングスイッチャーを筐体内に同時に構成することができます。それぞれのフォーマットに対するクロスポイントのサイズは下表のとおりです。

インテグレーテッド・ルーティングシステム IXS-6600/6700の制御システムIXS-6600/6700 では、システム設定にはPCのターミナルエミュレーターを使用し、信号の切り換えにはリモコンパネル(ルーティングスイッチャーコントロールユニット)などの制御装置を使用します。付属のルーティングスイッチャーリモートコントロールソフトウェア BZR-21(GUI ソフトウェア)でも PC上で基本的なクロスポイントの切り換えができます。制御システムには、BNC型のREMOTE 1 端子を使用するS-BUS、D-sub 9 ピンの REMOTE 2 端子を使用する RS-422A、REMOTE 3 端子を使用する RS-232C、およびNETWORK端子を使用するイーサネットの 4種類があります。4系統の制御を同時に使うこともできます。

S-BUSによる制御S-BUS は、ソニーがルーティングスイッチャーシステムの制御用に開発したプロトコルです。複数のルーティングスイッチャーとリモコンパネル(ルーティングスイッチャーコントロールユニット)を、1本の同軸ケーブルで接続し、通信することができます。S-BUS により制御できる機器の台数は、ルーティングスイッチャー、リモコンパネルなど合わせて254 台です。IXS-6600/6700 では、RS-422A のコマンドを S-BUS コマンドに変換することにより、D-sub 9 ピンの REMOTE 2 端子を通した S-BUS 制御も可能です。

RS-422Aによる制御本システムでは、RS-422A のコマンドを内部で S-BUS のコマンドに変換して、REMOTE 2 端子から S-BUS 制御をすることも可能です。RS-422A コマンドでそのまま制御するモードをダイレクトモード、S-BUS コマンドに変換して制御するモードを S-BUS 変換モードとよびます。S-BUS 変換モードでは、制御できる系統を最大 1024 系統、8レベルの入出力まで拡張できますが、応答速度はダイレクトモードより遅くなります。

制御できる内容は、RS-422A 用プロトコルで行えるものに限定されます。S-BUS リモートが 1次局に設定されると S-BUS 変換モードに固定され、2次局に設定されるとダイレクトモードに固定されます。

レベル設定による複数信号の同時制御多種類の信号を同時に扱う場合、それぞれの信号別にルーティングスイッチャーが必要になります。たとえば、VTRで記録を行うために必要な信号には、ビデオ、オーディオ、タイムコード、リモートコントロールがあり、それぞれビデオ、オーディオ、タイムコード、リモートの各ルーティングスイッチャーで信号を切り換えます。これらの切り換えを行う信号を総称してレベルと呼びます。本システムでは最大16 種類のレベルを設定し、レベルごとに異なる入力信号の番号を設定して同時に制御することができます。

インテグレーテッド・ルーティングシステム IXS-6600/6700の機能IXS-6600/6700 は次のような機能を備えています。

設定した入出力系統の保護機能設定した出力系統を、他のリモコンパネル(ルーティングスイッチャーコントロールユニット)から切り換えられないようにするプロテクト機能と、入力系統をすべてリモコンパネルから隠して切り換えられないようにするシークレット機能を備えています。

クロスポイントを無効にする機能出力系統ごとに選択できる入力系統を制限し、特定の入力系統を指定した出力系統にしか出力できないようにすることができます。

パスワード機能パスワードを設定しておき、オペレーターを制限することができます。

名称設定機能入出力端子に名称を設定し、接続する信号を識別できます。名称は 2種類の設定方法があり、ひとつは「タイプ名(VTR、カメラなどの機器名)+番号」(例:VTR1)で、もうひとつは任意の 16 文字の名前をつける「デスクリプション(記述)名称」です。設定した名称は、別売りのコントロールユニット BKS-R1617/R1618/R3216/R3219/R3220 に表示させることができます。

バーチャルマッピッング機能仮想マトリックス上にクロスポイントを配置することができます。

信号フォーマット マトリックスサイズ

SDI ルーター部 64 × 68(うち HD SDI は 16 × 17)

デジタルオーディオルーター部 64 × 68

RS-422A ルーター部 28 ポート

概要 13

Page 14: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

14

フリーアサイメント機能ひとつの端子名称に、レベルごとに異なる端子番号を割り当てることができます。

タイライン機能3 台までのルーティングスイッチャーを接続する信号線を自動的に選択できます。

ファントム機能複数のクロスポイントを同時に切り換えることができます。

自己診断機能入出力の有無やエラーの発生を、前面のステータス表示ランプに表示したり、一次局に接続したターミナルエミュレーターに表示させることができます。また後面のALARM出力端子にパラレルで出力することも可能です。

◆ 詳しくは、付属のシステムセットアップマニュアルをご覧ください。

S-BUS制御システムの特長S-BUS 制御システムでは、複数のルーティングスイッチャーとリモコンパネル(ルーティングスイッチャーコントロールユニット)を 1本の同軸ケーブルで接続し、制御信号の通信を行います。ひとつの S-BUS 制御システム内の 1台のスイッチャーを 1次局に設定し、この 1次局がシステム全体の制御を行います。ほかのスイッチャーとリモコンパネルは 2次局になり、1次局の制御により信号の通信を行います。

S-BUS 制御システムは次のような特長があります。• 75Ω同軸ケーブル 1本による、LAN(Local Area Network)形式の制御信号の通信

• 同軸ケーブル(5C-2V ケーブル使用時)を 500 m まで延長可能

• 電源を切らずにシステムを動作状態のまま、S-BUS ラインへの接続、取り外しが可能

• 1 次局に設定したルーティングスイッチャーは、複数の S-BUS ラインを制御し、最大 254 台(1 次局を含む)までのルーティングスイッチャーとリモコンパネルを制御

• 1本のS-BUSラインには、最大128台のルーティングスイッチャーとリモコンパネルが接続可能

• 自己診断機能によって検出されたエラーの内容を、S-BUSライン上の 1次局に接続された PC(ターミナルエミュレーター)に表示

• PC(ターミナルエミュレーター)で設定した内容(システムの設定やテーブルデータ)およびクロスポイントデータを、付属のルーティングスイッチャーデータバックアップソフトウェア BZR-20 を使用してPCのハードディスクに保存し、必要に応じて復元可能

概要

Page 15: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

システム接続例

主要構成機器本システムは 75Ω同軸ケーブルで接続された S-BUS データリンクを核に形成されます。S-BUS データリンクの主要構成機器は以下のとおりです。

接続時のご注意• 1 次局に使用するインテグレーテッド・ルーティングシステムでは、内部 CPU基板の P/S スイッチ1) を Pに設定します。

• 2 次局に使用するルーティングスイッチャーでは、内部CPU基板の P/S スイッチ1) を Sに設定します。

• 1本のS-BUSラインに接続できる2次局は最大128台です。• 1本のS-BUSラインのケーブル長は最大500 m(5C-2Vケーブル使用時)です。

• S-BUS ラインの最終機に取り付けるT型ブリッジ、および各スイッチャーの使用しない REMOTE 1 端子は、必ず75Ω終端器で終端してください。

• 2次局のルーティングスイッチャーのREMOTE 1端子は1個のみ使用可能です。

1) IXS-6600/6700 では CA-65 基板の S1203-3 P/S スイッチ

T型ブリッジ(Bタイプ)の使いかたIXS-6600/6700 には、BタイプのT型ブリッジが付属しています。使用するときは、50 cm以下の同軸ケーブル(5C-2V)を用意し、次のように接続してください。

S-BUSデータリンク主要構成機器

S-BUSデータリンク上の種別

使用機器 台数 機能

1 次局 システムコントローラー

ルーティングスイッチャーコントローラー

HKSP-R80 1 S-BUS データリンク全体の通信制御。同時に 2次局として動作することも可能。

ルーティングスイッチャー

インテグレーテッド・ルーティングシステム

IXS-6600/6700

ルーティングスイッチャープロセッサー

HDS-X5800

2 次局 ルーティングスイッチャー

ルーティングスイッチャープロセッサー

HDS-X5800 最大 253 台 各機器ごとの通信制御。1次局からの指示に従って動作する。

インテグレーテッド・ルーティングシステム

IXS-6600/6700

リモコンパネル(ルーティングスイッチャーコントロールユニット)

X-Y コントロールユニット BKS-R3220

32 ボタンコントロールユニット BKS-R3219

ユニバーサルコントロールユニット BKS-R1617

16 ボタンコントロールユニット BKS-R1618

8 デスティネーションコントロールユニット

BKS-R3216

ターミナル ターミナルエミュレーター PC 一般 1 システムの各種設定。S-BUS ラインで発生したエラーの表示と管理。

REMOTE 1 端子(BNC型、凹) T型ブリッジ

(Bタイプ)

5C-2V同軸ケーブル(50 cm以下)

概要 15

Page 16: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

16

接続例IXS-6700 を 1 次局とする S-BUS データリンクの接続例を示します。モニター S-BUS 系のコントロール機能はありません。

Network A

RE

MO

TE

1 A

RE

MO

TE

1 C

RE

MO

TE

1 B

2

RE

MO

TE

1 B

1

Network B

ターミナル ターミナル

パーソナルコンピューター(ターミナルエミュレーター)

a)(S) は2次局を表します。2次局の機器には、2~254のステーション ID を重複しないように設定してください。

パーソナルコンピューター(ターミナルエミュレーター)

:S-BUS:信号系ライン:イーサネット:T型ブリッジ(A):T型ブリッジ(B):75Ω終端器:マトリックスの階層1 次局 レベル1

インテグレーテッド・ルーティングシステムIXS-6700 (P)

イーサネットハブ

ビデオ

オーディオチャンネル1/2オーディオチャンネル3/4

タイムコード

デスティネーションVTR

ビデオ

ソースVTR

2 次局 レベル2 レベル 3 レベル 4 レベル 8

オーディオルーティングスイッチャー (S)a)

オーディオルーティングスイッチャー (S)a)

タイムコードルーティングスイッチャー (S)a)

各種ルーティングスイッチャー (S)a)

オーディオチャンネル 1/2

オーディオチャンネル3/4

タイムコード

最大128 台

最大16台

リモコンパネル

リモコンパネル

リモコンパネル

サブネットコントローラー

サブネットコントローラー

リモコンパネル

リモコンパネル

3次局

ディスプレイユニット

ディスプレイユニット

ディスプレイユニット

ディスプレイユニット

概要

Page 17: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

各部の名称と働き

インテグレーテッド・ルーティングシステム IXS-6600

前面

a POWER(電源)スイッチ本機の電源をON/OFFします。電源ユニットAと Bはバックアップ動作を行っていますので、使用するときは両方のスイッチをONにしてください。

b POWER(電源)表示ランプそれぞれ対応する電源ユニットに通電されると点灯します。正常動作時は緑で点灯し、各ユニット内のファンが停止すると赤で点灯します。

電源投入時に一瞬表示ランプが赤く点灯したり、両方のPOWERスイッチがONの状態で片側のPOWERスイッチをOFFにしたときに、OFFになっている電源ユニットの表示ランプが赤く点灯したりすることがありますが、これは故障ではありません。また、両方の POWERスイッチがONの状態で、片側のPOWERスイッチをOFFにした後すぐに POWERスイッチを再びONにすると、まれにONにした電源ユニットの表示ランプが赤く点灯したままになることがあります。このようなときは、表示ランプが赤く点灯している電源ユニットの

POWERスイッチをOFFにして表示ランプが消灯するまで20 秒ほど待ってから、POWERスイッチを再びONにしてください。すべてのPOWER スイッチをONにした後、POWERスイッチやブレーカーをOFF にする場合は、20 秒以上待ってからOFF にしてください。

c 表示部本機の状態を表示します。

◆ 詳しくは、「ステータス表示」(26 ページ) をご覧ください。

d ステータス表示ランプランプの色や点灯によって、本機の状態を表示します。本機の電源が入り、正常に動作しているときは消灯または緑で点灯します。エラーが発生すると赤点灯で知らせます。

◆ 詳しくは「エラー表示と対策」(29 ページ)をご覧ください。

e 操作ボタン表示部の表示を切り換えます。

◆ 詳しくは、「ステータス表示」(26 ページ) をご覧ください。

POWER A

POWER B

INTEGRATED ROUTING SYSTEM IXS-6600MENU ENTERCANCEL

aPOWERスイッチbPOWER表示ランプ

dステータス表示ランプe操作ボタン

c表示部

ご注意

各部の名称と働き 17

Page 18: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

18

後面

a 出力基板用スロット別売りの出力基板を装着します。

◆ 別売り出力基板の詳細は、「IXS-6600/6700 の商品構成」(8ページ)をご覧ください。

b 入力基板用スロット別売りの入力基板を装着します。

◆ 別売り入力基板の詳細は、「IXS-6600/6700 の商品構成」(8ページ)をご覧ください。

c REMOTE 3(リモート3)端子(D-sub 9 ピン)本機をシステムの 1次局1)(CA-65 基板の S1203-3 P/S スイッチを P側)に設定している場合、システムの動作に必要な設定を行うためのターミナルエミュレーターを、この端子に接続します。接続にはインチねじ付きのD-sub 9 ピンコネクターをお使いください。

この端子を使うときは、CA-65 基板の S1203-3 P/S スイッチを P側に設定してください。

◆ 詳しくは、付属のインストレーションマニュアルをご覧ください。

1) S-BUS プロトコルによるリモート制御では、1本の同軸ケーブルラインでデータ伝送路を構成し、データリンク内の複数の機器(ルーティングス

イッチャー、リモコンパネル(ルーティングスイッチャーコントロールユニット)など)が、時分割方式でそのデータ伝送路を利用します。各機器のうち、伝送路利用の管理を行うのが 1次局で、2次局は 1次局の指示に従って伝送路を利用します。このため、多数の 2次局が接続されると、数に応じて応答速度が遅くなります。

d REMOTE 2(リモート2)端子(D-sub 9 ピン)RS-422A インターフェースを介して、外部のコントローラーと接続します。本機を 1次局(CA-65 基板の S1203-3 P/S スイッチを P側)に設定すると S-BUS 変換モードになり、この端子を使ってS-BUS 制御が可能になります。接続にはミリねじ付きのD-sub 9 ピンコネクターをお使いください。

◆ 詳しくは、付属のシステムセットアップマニュアルをご覧ください。

e REMOTE 1(リモート1)端子(BNC型)A、B、Cの 3系統がそれぞれ 1端子ずつあり、合計 3端子です。S-BUS 制御を行うために、リモコンパネル(ルーティングスイッチャーコントロールユニット)やルーティングスイッチャーを同軸ケーブルで接続します。本機が 1次局(CA-65 基板の S1203-3 P/S スイッチが P側)に設定されている場合は、合計 253 台までのリモコンパネルやルーティングスイッチャーを接続できます。

OUT1

OUT2

IN1

IN2

OUT3

OUT4

IN3

IN4

A

REMOTE 1A

REFINA

75ΩON

OFF

REMOTE 1B

REFINB

75ΩON

OFF

REMOTE 1C

WORDSYNC

IN75ΩON

OFF

TC IN

NETWORK

REMOTE 2

REMOTE 3

REMOTE 2/ALARM

B

B AU

- AC IN

a出力基板用スロット

b入力基板用スロット

dREMOTE 2 端子

eREMOTE 1 端子

fREF IN端子と75Ω終端スイッチ

cREMOTE 3 端子

gWORD SYNC IN 端子と75Ω終端スイッチ

hTC IN 端子iREMOTE 2/ALARM端子

jNETWORK端子kAC IN 端子

lU(アース)端子

ご注意

各部の名称と

働き
Page 19: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

本機が 2次局(CA-65 基板の S1203-3 P/S スイッチが S側)に設定されている場合は、どれかひとつの端子を付属のT型ブリッジ(B)を使って S-BUS リンクと接続します。

◆ 詳しくは、「システム接続例」(15 ページ)をご覧ください。

使用しない端子には、1次局、2次局とも付属の 75Ω終端器を接続してください。

f REF IN(同期信号入力)端子(BNC型)と75Ω終端スイッチA、Bの 2系統の端子です。アナログのリファレンスビデオ信号(CCIR624 に準拠したブラックバースト信号またはHDTV用 3値シンク)を入力します。

75Ω終端スイッチ入力インピーダンスを切り換えます。ON:入力信号は 75Ωで終端されます。OFF:ハイインピーダンスになります。外部同期信号をループスルーで使用するとき、この位置にします。

信号の切り換えをリファレンスビデオ信号に同期させたいときは、切り換えタイミング(奇数フィールドまたは偶数フィールド)やリファレンス信号A/B の選択をターミナルエミュレーターから設定する必要があります。

◆ 詳しくは、付属のシステムセットアップマニュアルをご覧ください。

g WORD SYNC IN(オーディオワードシンク入力)端子(BNC型)と75Ω終端スイッチオーディオワードシンク信号を入力します。

75Ω終端スイッチ入力インピーダンスを切り換えます。ON:入力信号は 75Ωで終端されます。OFF:ハイインピーダンスになります。外部同期信号をループスルーで使用するとき、この位置にします。

h TC IN(タイムコード入力)端子(BNC型)タイムコード信号入力用の端子です。

i REMOTE 2/ALARM(リモート2 /アラーム)端子(D-sub 9ピン)本機の状態を出力します。REMOTE2 端子のB系統として使うこともできます。接続にはミリねじ付きのD-sub 9 ピンコネクターをお使いください。

◆ 詳しくは、「主な仕様」(33 ページ)、付属のインストレーションマニュアルおよびシステムセットアップマニュアルをご覧ください。

j NETWORK(ネットワーク)端子(モジュラージャック)A、Bの 2系統、100 BASE-TX通信用の 2端子です。付属の BZR-20/21 をインストールしたPCのイーサネットコネクターと接続します。

安全のために、周辺機器を接続する際は、過大電圧を持つ可能性があるコネクターを以下のポートに接続しないでください。• NETWORK A 端子• NETWORK B 端子上記のポートについては本書の指示に従ってください。

k AC IN(AC電源入力)端子A、Bの 2端子です。AC電源コードを使用して、AC電源に接続します。電源ユニットAと Bでそれぞれバックアップ動作を行っていますので、使用するときは 2つのインレットの両方に接続してください。

lU(アース)端子アースに接地してください。

ご注意

ご注意

ご注意

各部の名称と働き 19

Page 20: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

20

インテグレーテッド・ルーティングシステム IXS-6700

前面

a POWER(電源)スイッチ本機の電源をON/OFFします。電源ユニットA1と B1、A2と B2 でそれぞれバックアップ動作を行っていますので、使用するときは 4 個すべてをONにしてください。

b POWER(電源)表示ランプそれぞれ対応する電源ユニットに通電されると点灯します。正常動作時は緑で点灯し、各ユニット内のファンが停止すると赤で点灯します。

電源投入時に一瞬表示ランプが赤く点灯したり、すべてのPOWERスイッチがONの状態で一部の POWERスイッチをOFFにしたときに、OFFになっている電源ユニットの表

示ランプが赤く点灯したりすることがありますが、これは故障ではありません。また、すべての POWERスイッチがONの状態で、一部のPOWER スイッチをOFF にした後すぐにPOWER スイッチを再びONにすると、まれにONにした電源ユニットの表示ランプが赤く点灯したままになることがあります。このようなときは、表示ランプが赤く点灯している電源ユニットのPOWER スイッチをOFF にして表示ランプが消灯するまで20 秒ほど待ってから、POWERスイッチを再びONにしてください。すべての POWERスイッチをONにしたあと、POWERスイッチやブレーカーをOFFにする場合は、20 秒以上待ってからOFFにしてください。

INTEGRATED ROUTING SYSTEM IXS-6700MENU ENTERCANCEL

POWER A1

POWER A2

POWER B1

POWER B2

aPOWERスイッチ

bPOWER表示ランプ

c表示部dステータス表示ランプ

e操作ボタン

ご注意

各部の名称と働き

Page 21: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

c 表示部本機の状態を表示します。

◆ 詳しくは「ステータス表示」(26 ページ)をご覧ください。

d ステータス表示ランプランプの色や点灯によって、本機の状態を表示します。

本機の電源が入り、正常に動作しているときは消灯または緑で点灯します。エラーが発生すると赤点灯で知らせます。

◆ 詳しくは「エラー表示と対策」(29 ページ)をご覧ください。

e 操作ボタン表示部の表示を切り換えます。

◆ 詳しくは「ステータス表示」(26 ページ)をご覧ください。

後面

a 出力基板用スロット別売りの出力基板を装着します。

◆ 別売り出力基板の詳細は、「IXS-6600/6700 の商品構成」(8ページ)をご覧ください。

b 入力基板用スロット別売りの入力基板を装着します。

◆ 別売り入力基板の詳細は、「IXS-6600/6700 の商品構成」(8ページ)をご覧ください。

U

A

NETWORK REMOTE 2

REF IN

REMOTE 3 ALARM

B

A B

A

B

WORDSYNC IN

A

B

REMOTE 1

TC IN

A

B1

C

B2

OUT1

OUT2

IN1

IN2

OUT3

OUT4

IN3

IN4

OUT5

OUT6

IN5

IN6

OUT7

OUT8

IN7

IN8

OUT1 A1

A2

OUT2

IN1

IN2

OUT3

OUT4

IN3

IN4

B2

B1

15

9 6

15

9 6

15

9 6

- AC IN

- AC IN

- AC IN

- AC IN

a出力基板用スロット b入力基板用スロット

dREF IN 端子

eWORD SYNC IN 端子

fREMOTE 1 端子

cAC IN 端子

gTC IN 端子

hU(アース)端子

iNETWORK 端子jREMOTE 2 端子

kREMOTE 3 端子lALARM端子

cAC IN 端子

各部の名称と働き 21

Page 22: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

22

c AC IN(AC電源入力)端子A1、A2、B1、B2 の 4端子です。AC電源コードを使用して、AC電源に接続します。電源ユニットA1と B1、A2と B2 でそれぞれバックアップ動作を行っていますので、使用するときは 4つのインレットのすべてに接続してください。

d REF IN(同期信号入力)端子(BNC型)A、Bの 2系統、ループスルー付き 4端子です。アナログのリファレンスビデオ信号(CCIR624 に準拠したブラックバースト信号またはHDTV用 3値シンク)を入力します。各 2個の端子は内部でスルー接続されています。スルーアウト信号を使用しないときは、使用しない端子に市販の 75Ω終端器を接続して終端してください。

信号の切り換えをリファレンスビデオ信号に同期させたいときは、切り換えタイミング(奇数フィールドまたは偶数フィールド)やリファレンス信号A/Bの選択をターミナルエミュレーターから設定する必要があります。

◆ 詳しくは、付属のシステムセットアップマニュアルをご覧ください。

e WORD SYNC IN(オーディオワードシンク入力)端子(BNC型)A、Bの 2系統、ループスルー付き 4端子です。オーディオワードシンク信号を入力します。各 2個の端子は内部でスルー接続されています。スルーアウト信号を使用しないときは、使用しない端子に市販の 75Ω終端器を接続して終端してください。

f REMOTE 1(リモート1)端子(BNC型)A、B、Cの 3系統があり、A、Cはそれぞれ 1端子、Bのみ B1、B2 の 2端子で、合計 4端子です。S-BUS 制御を行うために、リモコンパネルやルーティングスイッチャーを同軸ケーブルで接続します。本機が 1次局1)(CA-65 基板の S1203-3 P/S スイッチが P側)に設定されている場合は、合計 253 台までのリモコンパネルや他のルーティングスイッチャーを接続できます。本機が 2次局1)(CA-65 基板の S1203-3 P/S スイッチが S側)に設定されている場合は、どれかひとつの端子を付属のT型ブリッジ(B)を使って S-BUS リンクと接続します。

◆ 詳しくは、「システム接続例」(15 ページ)をご覧ください。

使用しない端子には、1次局、2次局とも付属の 75Ω終端器を接続してください。

1) S-BUS プロトコルによるリモート制御では、1本の同軸ケーブルラインでデータ伝送路を構成し、データリンク内の複数の機器(ルーティングス

イッチャー、リモコンパネル(ルーティングスイッチャーコントロールユニット)など)が、時分割方式でそのデータ伝送路を利用します。各機器のうち、伝送路利用の管理を行うのが 1次局で、2次局は 1次局の指示に従って伝送路を利用します。このため、多数の 2次局が接続されると、数に応じて応答速度が遅くなります。

g TC IN(タイムコード入力)端子(BNC型)タイムコード信号入力用の端子です。

h U(アース)端子アースに接続(接地)してください。

i NETWORK(ネットワーク)端子(モジュラージャック)A、Bの 2系統、100BASE-TX通信用の 2端子です。付属のBZR-20/21 をインストールしたPCのイーサネットコネクターと接続します。

安全のために、周辺機器を接続する際は、過大電圧を持つ可能性があるコネクターを以下のポートに接続しないでください。• NETWORK A 端子• NETWORK B 端子上記のポートについては本書の指示に従ってください。

j REMOTE 2(リモート2)端子(D-sub 9 ピン)A、Bの 2系統です。RS-422A インターフェースを介して、外部のコントローラーと接続します。本機を 1次局(CA-65 基板の S1203-3 P/S スイッチが P側)に設定すると S-BUS 変換モードになり、この端子を使ってS-BUS 制御が可能になります。接続にはミリねじ付きのD-sub 9 ピンコネクターをお使いください。

◆ 詳しくは、付属のシステムセットアップマニュアルをご覧ください。

k REMOTE 3(リモート3)端子(D-sub 9 ピン)本機をシステムの 1次局(CA-65 基板の S1203-3 P/S スイッチをP側)に設定している場合、システムの動作に必要な設定を行うためのターミナルエミュレーターを、この端子に接続します。接続にはインチねじ付きのD-sub 9 ピンコネクターをお使いください。

この端子を使うときは、CA-65 基板の S1203-3 P/S スイッチをP側に設定してください。

◆ 詳しくは、付属のインストレーションマニュアルをご覧ください。

ご注意

ご注意

ご注意

ご注意

各部の名称と働き

Page 23: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

l ALARM(アラーム)端子(Mini D-sub 15 ピン)前面のステータス表示ランプと同様に、本機の状態を出力します。接続にはミリねじ付きのミニD-sub 15 ピンコネクターをお使いください。

◆ 詳しくは、「主な仕様」(33 ページ)および付属のインストレーションマニュアル、システムセットアップマニュアルをご覧ください。

オプション基板

16 HD/SDデジタルビデオインプットボード IKS-V6010M

a HD/SD IN 1 ~ 16端子(BNC型)SDI 信号(143 ~ 1485 Mbps) を入力します。

16 SDデジタルビデオインプットボード IKS-V6010SD

a SD IN 1 ~ 16端子(BNC型)SDTV SDI 信号(143 ~ 360 Mbps) を入力します。

32 D-sub AES/EBUインプットボード IKS-A6011

a AES/EBU IN 1-12、13-24端子(D-sub 37 ピン)AES/EBUデジタルオーディオ信号を入力します。

b AES/EBU IN 25-32端子(D-sub 25 ピン)AES/EBUデジタルオーディオ信号を入力します。

16 BNC AES/EBUインプットボード IKS-A6012

a AES/EBU IN 1 ~ 16端子(BNC型)AES/EBUデジタルオーディオ信号を入力します。

7 RS-422インプットボード IKS-RS6010

a RS-422 IN 1 ~ 7端子(D-sub 9ピン)RS-422A 信号を入力します。

1

HD/SD

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 IN

aHD/SD IN 1 ~ 16端子

SD

21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 IN

aSD IN 1 ~ 16端子

119

37 20

119

37 20

113

25 14

AES/EBU 1-12

13-24 25-32 IN

aAES/EBU IN 1-12、13-24 端子

bAES/EBU IN 25-32 端子

AES/EBU

21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 IN

aAES/EBU IN 1 ~ 16端子

115

9 6

215

9 6

315

9 6

415

9 6

515

9 6

615

9 6

7 IN15

9 6

RS-422

aRS-422 IN 1 ~ 7端子

各部の名称と働き 23

Page 24: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

24

16タイムコードインプットボード IKS-TC6010

a TIME CODE IN1 ~ 16端子(BNC型)タイムコード信号(LTC)を入力します。

17 HD/SDデジタルビデオアウトプットボード IKS-V6060M

a HD/SD OUT 1 ~ 17端子(BNC型)SDI 信号(143 ~ 1485 Mbps)を出力します。

17 SDデジタルビデオアウトプットボード IKS-V6060SD

a SD OUT 1~ 17端子(BNC型)SDTV SDI 信号(143 ~ 360 Mbps) を出力します。

34 D-sub AES/EBUアウトプットボード IKS-A6061

a AES/EBU OUT 1-12、13-24端子(D-sub 37 ピン)AES/EBUデジタルオーディオ信号を出力します。

b AES/EBU OUT 25-32端子(D-sub 25ピン)AES/EBUデジタルオーディオ信号を出力します。

c AES/EBU OUT 33-34端子(D-sub 9 ピン)AES/EBUデジタルオーディオ信号を出力します。

17 BNC AES/EBUアウトプットボード IKS-A6062

a AES/EBU OUT 1 ~ 17端子(BNC型)AES/EBUデジタルオーディオ信号を出力します。

7 RS-422アウトプットボード IKS-RS6060

a RS-422 OUT 1 ~ 7端子(D-sub 9 ピン)RS-422A 信号を出力します。

TIME CODE

21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 IN

aTIME CODE IN 1 ~ 16端子

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

OUTHD/SD

aHD/SD OUT 1~17端子

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

OUTSD

aSD OUT 1 ~ 17端子

119

37 20

119

37 20

113

25 14

15

9 6

AES/EBU 1-12

13-24 25-32 33-34 OUT

aAES/EBU OUT 1-12、13-24 端子

bAES/EBU OUT 25-32 端子

cAES/EBU OUT 33-34 端子

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

OUTAES/EBU

aAES/EBU OUT 1~17端子

115

9 6

215

9 6

315

9 6

415

9 6

515

9 6

615

9 6

7 OUT15

9 6

RS-422

aRS-422 OUT 1 ~ 7端子

各部の名称と働き

Page 25: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

17 タイムコードアウトプットボード IKS-TC6060

a TIME CODE OUT 1 ~ 17端子(BNC型)タイムコード信号(LTC)を出力します。

TIME CODE

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

OUT

aTIME CODE OUT 1~17端子

各部の名称と働き 25

Page 26: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

26

ステータス表示

前面の操作ボタンを使って、運用中の本機の状態を表示部に 表示することができます。

表示項目表示部に表示される項目は以下のようなツリー構成で、操作ボタンで表示を切り換えることができます。

表示部のバックライトは、約5分間キー操作がないと消灯し、ボタンをどれか押すと再び点灯します。

xxxxxxxx ERR

xxxxxxxx ERR

SBUS STATION ID

IP ADDRESS

CPU SW SETTING

CPU RUN

INTEGRATED ROUTING SYSTEM

ERROR STATUS

DISP UNIT STATUS

FAN ELAPSED TIME

PSU ELAPSED TIME

[MENU]

[ENTER]

[CANCEL]

[MENU]

[MENU]

[MENU]

[ENTER]

[CANCEL]

$4

$4

$4

$4

$4

$4

$4

$4

$4

$4

$4

トップ表示

エラーの内容を重要度の高い順に表示します。◆表示内容は「エラーステータス」(30 ページ)を参照してください。

エラー表示:機器内のエラーを表示します。

メイン /バックアップのどちらのCPUが働いているかを表示します。

CA基板のDIP スイッチの設定を表示します。

CPUのネットワーク接続の IP アドレスを表示します。

S-BUSのステーション ID を表示します。

トップメニュー

ステータス表示:機器の状況や、設定の状態を表示します。

電源ユニットの使用積算時間を表示します。

ファンユニットの使用積算時間を表示します。

ステータス表示

Page 27: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

操作ボタンの働き

a MENUボタントップ表示に戻ります。

b CANCELボタントップメニューより下の階層にいるとき、ひとつ上の階層に移動します。設定を変更したときに、変更した内容を取り消して、現在保存されている設定に戻ります。

c ENTERボタン下の階層に移動します。設定を変更したときに、変更した内容を保存します。MENUボタンと同時に押すと、設定メニューに移行します。

d G、 gボタン選択肢や変更する数値の桁を選択するときに押します。

e F、 fボタン同じ階層内で表示内容を変更するときに押します。

基本操作操作ボタンを使った基本操作は次のとおりです。

表示部にトップ表示を表示するにはMENUボタンを押します。INTEGRATED ROUTING SYSTEMが表示されます。バックライトが消灯しているときは、もう一度MENUボタンを押してください。点灯します。

ひとつ下の階層に移動するにはENTERボタンを押します。

ひとつ上の階層に戻るにはCANCELボタンを押します。

同じ階層で表示を切り換えるにはFまたは fボタンを押します。

トップ表示に戻るにはMENUボタンを押します。

機器の状態の確認本機のステータス表示機能を使って、内部基板のDIP スイッチの設定や S-BUS ステーションのステーション IDなどを表示することができます。次の手順で操作します。

1 MENU ボタンを押して、トップ表示を表示部に表示する。

2 Fまたは fボタンを押して表示部にDISP UNIT STATUS を表示する。

3 ENTERボタンを押す。

4 Fまたは fボタンを押して、設定を確認したい項目を選択する。

CPU RUN: メイン / バックアップのどちらのCPUが働いているか

CPU SW SETTING:CA-65 基板のDIP スイッチの設定

IP ADDRESS:CPUのネットワーク接続の IP アドレス

SBUS STATION ID:S-BUS ステーションのステーション ID

PSU ELAPSED TIME:各電源ユニットの使用積算時間

FAN ELAPSED TIME:各ファンユニットの使用積算時間

5 ENTERボタンを押す。

手順 4で選択した項目の設定が、表示部の 2行目に表示されます。Fまたは fボタンを押して表示される設定内容を切り換えることができます。

表示部のコントラストの調整表示部のコントラストを調整することができます。次の手順で操作します。

MENU ENTERCANCEL

aMENUボタン

bCANCEL ボタンcENTERボタン

dG、 gボタン

eF、 fボタン

ステータス表示 27

Page 28: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

28

1 MENUボタンを押して、表示部にトップ表示を表示する。

2 Gまたは gボタンを押して、コントラストを調整する。

gボタンを押すとコントラストは強くなり、Gボタンを押すと弱くなります。

ステータス表示

Page 29: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

エラー表示と対策

本機は、電源投入時または、リダンダント CPU基板のうちメイン側のリセットボタンが押されたと同時に自己診断を行い、その後の動作中にも定期的に自己診断を実行します。エラーを検出すると、直ちにステータス表示ランプによって知らせ、その内容をコントロールターミナル(PC上のターミナルエミュレーター)に出力します。

また、CA-65 基板上のステータス表示器にもエラーの内容が、エラーコードとエラー記号で表示されます。これらの情報をもとに、簡易的に故障箇所を知ることができます。ここでは、前面のステータス表示ランプ、および表示部に表示されるエラーと、その対策を示します。

ステータス表示ランプ電源投入時に数秒間ステータス表示ランプの表示が乱れることがありますが、これは異常ではありません。

ステータス表示ランプ

内容状態

対策緑点灯

オレンジ点灯

赤点灯

1 リダンダントステータス(電源ユニット、CA-65基板の状態)

正常(電源ユニットも CA-65 基板の動作もすべて正常である。)

• 2枚の CA-65基板のうち、どちらか一方がスロットに挿入されていない。

• 電源ユニットが抜けている。

• 電源ユニットの使用積算時間による電源ユニットの定期交換の時期を過ぎている。

• CA-65 基板の動作に異常がある。

• 電源ユニットに異常がある。

操作仕様に従って、エラー内容を確認し、その内容に応じて対策をとる。• 電源ユニットのスイッチがONになっているか確かめる。

• 電源ケーブルの接続を確かめる。• 不良の電源ユニットを交換する。• 不良の CA-65 基板を交換する

2 ユニットステータス(本体ファン、機器内温度、別売り基板の状態)

正常(本体ファン、機器内温度、別売り基板のすべてが正常である。)

• 本体ファンの使用積算時間による定期交換の時期を過ぎている。

• 本体ファン、機器内温度、別売り基板のいずれかが異常である。

操作仕様に従って、エラー内容を確認し、その内容に応じて対策をとる。• 不良のファンユニットを交換する。

• 不良の別売り基板を交換する。

3 リモートコントロ-ル /タイミングステータス(REMOTE1, NETWORK、基準信号入力の状態)

正常(REMOTE1, NETWORKの通信は正常、かつ通常の基準信号が入力されている。または基準信号がないが非同期でクロスポイントを切り換える設定になっている。)

― • REMOTE1 通信、NETWORK通信、リファレンスビデオ信号入力のいずれかに異常がある。

操作仕様に従って、エラー内容を確認し、その内容に応じて対策をとる。• REMOTE1、NETWORKの設定、接続を正しく行う。

• リファレンス信号を入力するか、クロスポイントの切リ換えタイミングを非同期(ASYNC)に設定する。◆詳しくは、付属のシステムセットアップマニュアルをご覧ください。

エラー表示と対策 29

Page 30: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

30

エラーステータス表示部に本機内のエラーの内容を表示することができます。次の手順で操作します。

1 MENUボタンを押して、トップ表示を表示部に表示する。

2 fボタンを押す。

ERROR STATUS が表示されます。

3 ENTERボタンを押す。

エラーの内容が重要度の高い順に表示されます。Fまたは fボタンを押して表示されるエラーの内容を切り換えることができます。

ひとつ上の階層に戻るにはCANCEL ボタンを押します。

トップ表示に戻るにはMENUボタンを押します。

エラーステータスと対策

表示 1行目 表示 2 行目 "x" に入る単語 内容 対策

REMOTE1 ERR DISCONNECT CH.xx

A/B1/B2/C • S-BUS 回線が断線した。 • 応答のない機器との接続を確認し、正しく接続する。

• 75Ω終端器を取り付ける。

REF ERR FAIL CH.x A/B 異常• リファレンスビデオ信号に同期してクロスポイントを切り換えるように設定されているが、リファレンスビデオ信号の入力がない。

• サポート外の基準信号が入力された。

• REF IN端子にリファレンスビデオ信号を入力する。

• リファレンスビデオ信号に同期してクロスポイントを切り換えるモードを解除する(ASYNCに設定する)。◆詳しくは、付属のシステムセットアップマニュアルをご覧ください。

W/S ERR FAIL CH.x A/B a) 異常• 本体にオーディオのオプション基板が挿入されているが、オーディオ用基準信号(ワードシンク)またはリファレンスビデオ信号の入力がない。

• WORD SYNC IN 端子にサポート外の基準信号が入力された。

• WORD SYNC IN 端子にオーディオワードシンク信号を入力する。

• REF IN端子にリファレンスビデオ信号を入力する。

MAIN CPU ERR MEM ERR ― • メインの CA-65 基板のバックアップ・データが壊れている。

• メイン動作中の CA-65 基板がどちらかを 「表示項目」(26 ページ)を参照して確認し、バックアップデータをインストレーションマニュアルを参照してダウンロードする。

BATT.VOLTAGE LOW

― • メインの CA-65 基板のバッテリーバックアップの電圧が異常である。

• メイン動作中の CA-65 基板がどちらかを「表示項目」(26 ページ)を参照して確認し、CA-65 基板のリチウム電池を交換する。

BACKUP CPU ERR

DOWN ― • バックアップの CA-65 基板に異常あり。 • メイン/バックアップ CA-65基板がどちらかを「表示項目」(26 ページ)を参照して確認し、バックアップの CA-65 基板を交換する。

PSU ERR FAIL xx A1/A2/B1/B2 b) • 電源ユニットに異常あり。 • 電源ユニットのスイッチがONになっているか確かめる。

• 電源ケーブルの接続を確かめる。• 不良の電源ユニットを交換する。

NON xx A1/A2/B1/B2 b) • 電源ユニットが装着されていない。 • 電源ユニットを装着する。

xx RUN HOUR OVER

A1/A2/B1/B2 b) • 本体電源ユニットの使用積算時間による定期交換の時期を過ぎている。

• 表示されている電源ユニットを交換する。

エラー表示と対策

Page 31: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

a) IXS-6600 のWORD SYNC IN 端子は 1系統ですが、内部でA、Bの 2系統に分配されています。

b) A2/B2は IXS-6600では表示されません。IXS-6600の電源ユニットA、Bは、表示部にはA1、B1と表示されます。

c) IXS-6600 では、5/6/7 は表示されません。d) 表示されるスロット番号は IXS-6700/6600後面の次の入出力基板用スロット番号に対応しています。

FAN ERR x UNIT FAIL L/R • 本体ファンユニットのうち 1つ以上が止まっているか、規定値以外の回転数になっている。

• 不良のファンユニットを交換する。

x RUN HOURS OVER

L/R • 本体ファンユニットの使用積算時間による定期交換の時期を過ぎている。

• OVER と表示されているファンユニットを交換する。

TEMP ERR HIGH ― • 本機内部の温度が規定以上に上昇した。 • 周囲の温度や通風状態を調べる。

XPT ERR INxxx-OUTxxx 入力と出力の端子番号

• クロスポイントに異常がある。 • 不良の別売り基板を交換する。

OPTION BD.ERR FRONT SLOTxx 1/2/3/4/5/6/7 c) • 本体に挿入されている別売りの基板(フロント基板)に異常がある。

• 不良の別売り基板を交換する。

• 間違ったスロットに挿入されている。 • 正しいスロットに挿入する。

REAR SLOTxx 1/2/3/4/5/6/7/8/9/10/11/12/13/14/15/16 d)

• 本体に挿入されている別売りの基板(リア基板)に異常がある。

• 不良の別売り基板を交換する。

• 間違ったスロットに挿入されている。 • 正しいスロットに挿入する。

S-BUS CPU ERR MAINx FAIL A/B/C • メイン側CPU基板上のS-BUS CPUxに異常がある。

• メイン側CA-65基板の不良のIF-844基板を交換する。

BACKUPx FAIL A/B/C • バックアップ側 CPU基板上の S-BUS CPUx に異常がある。

• バックアップ側CA-65基板の不良のIF-844基板を交換する。

表示 1 行目 表示 2 行目 "x" に入る単語 内容 対策

スロット番号 IXS-6700 IXS-6600

1 OUT1 OUT1

2 OUT2 OUT2

3 IN1 IN1

4 IN2 IN2

5 OUT3 OUT3

6 OUT4 OUT4

7 IN3 IN3

8 IN4 IN4

9 OUT5 ―

10 OUT6 ―

11 IN5 ―

12 IN6 ―

13 OUT7 ―

14 OUT8 ―

15 IN7 ―

16 IN8 ―

エラー表示と対策 31

Page 32: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

32

付属のソフトウェア

IXS-6600/6700 に付属のCD-ROMには、以下のソフトウェアが含まれています。

ルーティングスイッチャーデータバックアップソフトウェアBZR-20サービス用途としてご使用いただくためのソフトウェアです。IXS-6600/6700 の各種設定データのバックアップに使用します。Windows XP を搭載した IBM PC/AT互換機で使用できます。

◆ インストール手順など詳しくは、付属のインストレーションマニュアルをご覧ください。

ルーティングスイッチャーリモートコントロールソフトウェアBZR-21ルーティングスイッチャーの基本的なクロスポイント切り換え機能と、切り換え操作ボタンへの端子割り当て機能を備え、大小システム構築時の動作確認や、簡便なシステム運用を可能にします。Windows XP を搭載した IBM PC/AT互換機で使用できます。

BZR-21 のインストールルーティングスイッチャーリモートコントロールソフトウェア BZR-21 を使用することにより、PC上でクロスポイントの切り換えを実行できます。クロスポイントステータスを表示したり、ソースが選択されているデスティネーションを検索するサーチ機能も備えています。

動作環境ハードウェア:Windows XP を搭載した IBM PC/AT互換機

CPU:Pentium 互換プロセッサー CPUクロック 300 MHz以上

メインメモリー:128 MB以上ハードディスク空き容量:10 MB以上ディスプレイ装置:解像度 800 × 600 ドット以上インターフェース:RS-232C またはイーサネット

BZR-21によるクロスポイント切り換えの概要Button per Source 方式(あらかじめ端子を割り当てたボタンを押して切り換える方式)とX-Y方式(端子名称を指定して切り換える方式)を選択できます。Distribution 方式では、ひとつのソースに対して複数のデスティネーションを指定することが可能です。それぞれの切り換えは、ウィンドウのタブをクリックすることによって選択できます。

Button per Source 方式

X-Y 方式

Distribution 方式

付属のソフトウェア

Page 33: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

端子の割り当てButton per Source 方式での切り換えには、ドラッグ&ドロップによって、画面に表示される操作ボタンに端子を割り当てることができます。

インストールの手順

1 IXS-6600/6700に付属のCD-ROMを、PCのCD-ROMドライブに挿入する。

2 CD-ROM内の\BZR-21というフォルダー内のファイルをすべてハードディスクの任意のフォルダーにコピーする。

新しいフォルダーを作成する場合、英文字以外のフォルダー名は文字化けします。

3 コピーが終了したら、SETUP.EXEのアイコンをダブルクリックする。

インストールプログラムが起動しますので、表示される指示に従ってインストールを行ってください。

◆ 操作について詳しくは、BZR-21 のオンラインヘルプをご覧ください。

BZR-21 のオンラインヘルプの「BZR-21 の概要」には、「1次局との接続には、REMOTE 3(RS-232C)またはDATA(Ethernet)を使用します。」と書いてありますが、IXS-6600/6700 では、DATA端子の代わりにNETWORK端子(Ethernet)を使用します。

主な仕様

以下に述べる仕様では、本機およびオプション類の固有の性能を示します。

本機の仕様および外観は、改良のため予告なく変更することがありますが、ご了承ください。

インテグレーテッド・ルーティングシステム IXS-6700

一般電源 AC100 ~ 240 V、50 ~ 60 Hz消費電流(別売りユニットフル装備時の最大値)

AC100V 時:9.8 AAC240V 時:4.5 A

動作温度 5℃~ 40 ℃動作湿度 10%~ 90%(結露なし)性能保証温度 10 ℃~ 35 ℃質量(本体のみ) 約 28 kg外形寸法(幅 /高さ / 奥行き)

440 × 354 × 520 mm

組み込みユニット付属ユニット 電源ユニット(4)

CPUコントロールボード(2)別売りユニット マトリックスボード IKS-6030M

HD/SD ビデオ ルータープロセッサーボード IKS-V6050MSDビデオ ルータープロセッサーボード IKS-V6050SDオーディオ/データルータープロセッサーボード IKS-A605016 HD/SD デジタルビデオインプットボード IKS-V6010M16 SD デジタルビデオインプットボード IKS-V6010SD32 D-sub AES/EBUインプットボード IKS-A601116 BNC AES/EBUインプットボードIKS-A6012

ご注意

ご注意

この装置は、情報処理装置等電波障害自主規制協議会(VCCI)の基準に基づくクラスA情報技術装置です。この装置を家庭環境で使用すると、電波妨害を引き起こすことがあります。この場合には、使用者が適切な対策を講ずるように要求されることがあります。

主な仕様 33

Page 34: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

34

32 サンプリングレートコンバーターボード IKS-A60157 RS-422 インプットボード IKS-RS601016 タイムコードインプットボード IKS-TC601017 HD/SD デジタルビデオアウトプットボード IKS-V6060M17 SD デジタルビデオアウトプットボード IKS-V6060SD34 D-sub AES/EBUアウトプットボードIKS-A606117 BNC AES/EBUアウトプットボードIKS-A60627 RS-422 アウトプットボード IKS-RS606017 タイムコードアウトプットボード IKS-TC6060

入出力端子REMOTE 1 S-BUS リモート端子:BNC型(4)

データ転送速度:312/1250 Kbpsデータ転送方式:Bi-Phase Space信号伝達距離:500 m(312 Kbps にて、75Ω同軸ケーブル 5C-2 V 使用時)

REMOTE 2 D-sub 9 ピン、凹(2)RS-422A信号規格準拠(S-BUS コマンドに変換可)プロトコル:ソニーCart++データ転送速度 38.4 Kbps

REMOTE 3 D-sub 9 ピン、凸(1)RS-232C 信号規格準拠ターミナル接続用データ転送速度:38400 bps8 ビット、パリティなし、チェックなし、ストップビット 1

TC IN BNC型(1)ALARM ミニD-sub 15 ピン、凹(1)

パラレル、オープンコレクター 6出力REF IN BNC型(2)(ループスルー出力付き)

ブラックバーストHD 3 値シンクデジタルオーディオの同期信号として使用される場合:1125i/50、59.94、60750p/59.94、60625i/50525i/59.94、60525p/59.94

WORD SYNC IN BNC型(2)(ループスルー出力付き)NETWORK 100BASE-TX:モジュラージャック(2)

付属品オペレーションガイド(1)CD-ROM (1)内容;オペレーションマニュアル

インストレーションマニュアルシステムセットアップマニュアルルーティングスイッチャーデータバックアップソフトウェアBZR-20

ルーティングスイッチャーリモートコントロールソフトウェア BZR-21

75Ω終端器(3)T型ブリッジ(Bタイプ)(1)

別売り品AC電源コード(125 V、7 A、2.4 m)

部品番号:1-791-041-32

本機は高調波電流規格 JIS C 61000-3-2 適合品です。

インテグレーテッド・ルーティングシステム IXS-6600

一般電源 AC100 ~ 240 V、50 ~ 60 Hz消費電流(別売りユニットフル装備時の最大値)

AC100 V 時:6 AAC240 V 時:2.5 A

動作温度 5℃~ 40 ℃動作湿度 10%~ 90%(結露なし)性能保証温度 10 ℃~ 35 ℃質量(本体のみ) 約 17 kg外形寸法(幅 /高さ / 奥行き)

440 × 176 × 520 mm

組み込みユニット付属ユニット 電源ユニット(2)

CPUコントロールボード(2)別売りユニット マトリックスボード IKS-6030M

HD/SD ビデオ ルータープロセッサーボード IKS-V6050MSDビデオ ルータープロセッサーボード IKS-V6050SDオーディオ/データルータープロセッサーボード IKS-A605016 HD/SD デジタルビデオインプットボード IKS-V6010M16 SD デジタルビデオインプットボード IKS-V6010SD32 D-sub AES/EBUインプットボード IKS-A6011

主な仕様

Page 35: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

16 BNC AES/EBUインプットボードIKS-A601232 サンプリングレートコンバーターボード IKS-A60157 RS-422 インプットボード IKS-RS601016 タイムコードインプットボード IKS-TC601017 HD/SD デジタルビデオアウトプットボード IKS-V6060M17 SD デジタルビデオアウトプットボード IKS-V6060SD34 D-sub AES/EBUアウトプットボードIKS-A606117 BNC AES/EBUアウトプットボードIKS-A60627 RS-422 アウトプットボード IKS-RS606017 タイムコードアウトプットボード IKS-TC6060

入出力端子REMOTE 1 S-BUS リモート端子:BNC型(3)

データ転送速度:312/1250 Kbpsデータ転送方式:Bi-Phase Space信号伝達距離:500 m(312 Kbps にて、75Ω同軸ケーブル 5C-2V 使用時)

REMOTE 2/ALARMD-sub 9 ピン、凹(2)REMOTE 2:RS-422A 信号規格準拠(S-BUS コマンドに変換可)プロトコル:ソニー Cart++データ転送速度 38.4 KbpsALARM:パラレル、オープンコレクター 4出力

REMOTE 3 D-sub 9 ピン、凸(1)RS-232C 信号規格準拠ターミナル接続用データ転送速度:38400 bps8 ビット、パリティなし、チェックなし、ストップビット 1

TC IN BNC型(1)REF IN BNC型(2)

ブラックバーストHD 3 値シンクデジタルオーディオの同期信号として使用される場合:1125i/50、59.94、60750p/59.94、60625i/50525i/59.94、60525p/59.94

WORD SYNC IN BNC型(1)

NETWORK 100BASE-TX:モジュラージャック(2)

付属品オペレーションガイド(1)CD-ROM (1)内容;オペレーションマニュアル

インストレーションマニュアルシステムセットアップマニュアルルーティングスイッチャーデータバックアップソフトウェアBZR-20

ルーティングスイッチャーリモートコントロールソフトウェア BZR-21

75Ω終端器(2)T型ブリッジ(Bタイプ)(1)

別売り品AC電源コード(125 V、7 A、2.4 m)

部品番号:1-791-041-32

本機は高調波電流規格 JIS C 61000-3-2 適合品です。

オプションボード

マトリックスボード IKS-6030M

一般電源 DC12 V消費電流 4.2 A外形寸法(幅 /奥行き)

317 × 380 mm質量 約 1.3 kg

仕様マトリックスサイズ

128 入力× 68 出力(オーディオ信号を取り扱う場合は 256 入力× 136 出力)

データ転送速度 DC~ 1485 Mbps

付属品オペレーションアンドインストレーションガイド(1)

HD/SDビデオルータープロセッサーボード IKS-V6050M

一般電源 DC12 V消費電流 2.2 A外形寸法(幅 /奥行き)

317 × 380 mm質量 約 1.0 kg

主な仕様 35

Page 36: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

36

仕様処理信号数 34 系統データ転送速度 143 ~ 1485 Mbpsリクロック動作信号

SMPTE規格の 143、177、270、360、540、1483.5/1485 Mbps の各レートDVB/ASI 規格の 270 Mbps 信号

付属品オペレーションアンドインストレーションガイド(1)

SDビデオルータープロセッサーボード IKS-V6050SD

一般電源 DC12 V消費電流 2.2 A外形寸法(幅 /奥行き)

317 × 380 mm質量 約 1.0 kg

仕様処理信号数 34 系統データ転送速度 143 ~ 360 Mbpsリクロック動作信号

SMPTE規格の 143、177、270、360 Mbps の各レートDVB/ASI 規格の 270 Mbps 信号

付属品オペレーションアンドインストレーションガイド(1)

オーディオ /データルータープロセッサーボード IKS-A6050

一般電源 DC12V 消費電流 1.0 A外形寸法(幅 /奥行き)

317 × 380 mm質量 約 1.1 kg

仕様処理信号数 28 系統(データ信号 (RS-422A) の場合)

68 系統(AES/EBUデジタルオーディオ信号(バランス)の場合)

処理信号 デジタルオーディオ信号、RS-422A信号

付属品オペレーションアンドインストレーションガイド(1)

16 HD/SDデジタルビデオインプットボード IKS-V6010M

一般電源 DC12 V消費電流 1.0 A外形寸法(幅 /奥行き)

278 × 95.6 mm質量 約 0.4 kg

仕様入力数 16 入力(BNC型)入力信号 SDI 信号、0.8 Vp-p入力データ転送速度

143 ~ 1485 Mbps信号伝達距離 143 ~ 360 Mbps:200 m(5C-2V/

BELDEN8281 相当ケーブル使用時)540 Mbps:150 m(5C-2V/BELDEN8281相当ケーブル使用時)1485 Mbps:100 m(5C-FB/BELDEN1694 相当ケーブル使用時)

入力コネクターにBNCケーブルを接続し、その先端がオープンのままになっていると周囲のノイズにより、本機の信号有無検出回路が誤動作する場合があります。そのような場合は、ケーブルの先端を 75Ωで終端してください。

付属品オペレーションアンドインストレーションガイド(1)

16 SDデジタルビデオインプットボード IKS-V6010SD

一般電源 DC12 V消費電流 1.0 A外形寸法(幅 /奥行き)

278 × 95.6 mm質量 約 0.4 kg

仕様入力数 16 入力(BNC型)入力信号 SDTV SDI 信号、0.8Vp-p入力データ転送速度

143 ~ 360 Mbps信号伝達距離 200 m(5C-2V/BELDEN8281 相当ケーブ

ル使用時)

ご注意

主な仕様

Page 37: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

入力コネクターに BNCケーブルを接続し、その先端がオープンのままになっていると周囲のノイズにより、本機の信号有無検出回路が誤動作する場合があります。そのような場合は、ケーブルの先端を 75Ωで終端してください。

付属品オペレーションアンドインストレーションガイド(1)

32 D-sub AES/EBUインプットボード IKS-A6011

一般電源 DC12 V消費電流 0.34 A外形寸法(幅 /奥行き)

278 × 95.6 mm質量 約 0.3 kg

仕様入力数 32 入力(D-sub 37 ピン (2)、D-sub 25 ピ

ン (1))入力信号 リファレンスビデオ信号またはワードシ

ンクに同期したAES3-2003 およびAES-2id-1996(r2001)6.3 項に準拠の 24 ビットデジタルオーディオ信号

標準入力レベル 2~ 7 Vp-p(差動、110Ω終端時)最大入力レベル 10 Vp-p(差動、110Ω終端時)最小入力レベル 0.5 V (Fs=48 kHz)(差動、110Ω終端時)入力データ転送速度(サンプリングレート)

6.144 Mbps(Fs=48 kHz)信号伝達距離 6.144 Mbps:300 m 以上

(信号源レベル 5Vp-p 差動、デジタルオーディオ専用ケーブル使用時)

リファレンスビデオ信号またはワードシンクに同期していない入力信号、および上記のレート以外の入力信号に対応するためには、32 サンプリングレートコンバーターボード IKS-A6015 と合わせてお使いください。

付属品オペレーションアンドインストレーションガイド(1)

16 BNC AES/EBUインプットボード IKS-A6012

一般電源 DC12 V

消費電流 0.60 A外形寸法(幅 /奥行き)

278 × 95.6 mm質量 約 0.3 kg

仕様入力数 16 入力(BNC型)入力信号 リファレンスビデオ信号またはワードシ

ンクに同期したAES3-2003 およびAES-3id-1995 7 項に準拠の 24 ビットデジタルオーディオ信号

標準入力レベル 0.8 ~ 1.2 Vp-p(75Ω終端時)最大入力レベル 7 Vp-p(75Ω終端時)最小入力レベル AES-3id-2001 の 7.3 項Minimum input

signals に準拠Vmin=320 mV(75Ω終端時)

入力データ転送速度(サンプリングレート)6.144 Mbps(Fs=48 kHz)

信号伝達距離 6.144 Mbps:600 m以上(信号源レベル 1Vp-p、BELDEN8281ケーブル使用時)

リファレンスビデオ信号またはワードシンクに同期していない入力信号、および上記のレート以外の入力信号に対応するためには、32 サンプリングレートコンバーターボード IKS-A6015 と合わせてお使いください。

付属品オペレーションアンドインストレーションガイド(1)

32 サンプリングレートコンバーターボード IKS-A6015

一般電源 DC3.3 V(IKS-A6011 より供給)消費電流 0.96 A外形寸法(幅 /奥行き)

116 × 62 mm質量 約 0.1 kg

仕様入力数 32 入出力入出力信号 IKS-A6011 で受信復調された非圧縮

フォーマットの 24 ビットデジタルオーディオ信号

入力データ転送速度(サンプリングレート)4.928 ~ 6.144 Mbps(Fs=38.5 ~ 48 kHz)

出力データ転送速度(サンプリングレート)6.144 Mbps(Fs=48 kHz)

ご注意

ご注意

ご注意

主な仕様 37

Page 38: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

38

• 本基板は、32 D-sub AES/EBUインプットボード IKS-A6011 と合わせてお使いください。本基板のみで使用することはできません。

• AES-2003 規格書の Single channel double sampling frequency mode には対応しません。

付属品オペレーションアンドインストレーションガイド(1)

7 RS-422インプットボード IKS-RS6010

一般電源 DC12 V消費電流 0.15 A外形寸法(幅 /奥行き)

278 × 95.6 mm質量 約 0.3 kg

仕様信号数 7(D-sub 9 ピン)入出力信号 RS-422A信号入出力データ転送速度

RS-422A規格準拠信号伝達距離 1000 m

付属品オペレーションアンドインストレーションガイド(1)

16 タイムコード インプットボ-ド IKS-TC6010

一般電源 DC12 V消費電流 0.19 A外形寸法(幅/奥行き)

278 × 95.6 mm質量 約 0.4 kg

仕様入力数 16 入力(BNC型)入力インピーダンス1kΩ入力信号 SMPTE 12M-1999 の 8.6 項に定義されて

いる、電気的および機械的インターフェース特性に準拠したタイムコード信号(LTC)

標準入力レベル 1.0 ~ 2.0 Vp-p(1kΩ終端時)最大入力レベル 4.5 Vp-p(1kΩ終端時)

最小入力レベル 0.5 Vp-p(1kΩ終端時)入力デ-タ転送速度

1/4 倍速 ~ 10 倍速(NTSC/PAL)

付属品オペレ-ションアンドインストレ-ションガイド(1)

17 HD/SDデジタルビデオアウトプットボード IKS-V6060M

一般電源 DC12 V消費電流 0.35 A外形寸法(幅 /奥行き)

278 × 95.6 mm質量 約 0.4 kg

仕様出力数 17 出力(BNC型)出力振幅 0.8 Vp-p ± 10%データ転送速度 143 ~ 1485 MbpsSDI 信号出力 143、177、270、360 Mbps:

SMPTE259M準拠540 Mbps:SMPTE344M準拠1483.5/1485 Mbps:SMPTE292M準拠上記以外のレート:SMPTE259M/SMPTE292M選択可能

信号伝達距離 143 ~ 540 Mbps:200 m(5C-2V/BELDEN8281 相当ケーブル使用時)1485 Mbps:100 m(5C-FB/BELDEN1694 相当ケーブル使用時)

付属品オペレーションアンドインストレーションガイド(1)

17 SDデジタルビデオアウトプットボード IKS-V6060SD

一般電源 DC12 V消費電流 0.35 A外形寸法(幅 /奥行き)

278 × 95.6 mm質量 約 0.4 kg

仕様出力数 17 出力(BNC型)出力振幅 0.8 Vp-p ± 10%データ転送速度 143 ~ 360 Mbps

ご注意

主な仕様

Page 39: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

SDI 信号出力 143、177、270、360 Mbps:SMPTE259M準拠

信号伝達距離 200 m(5C-2V/BELDEN8281 相当ケーブル使用時)

付属品オペレーションアンドインストレーションガイド(1)

34 D-sub AES/EBUアウトプットボード IKS-A6061

一般電源 DC12 V消費電流 0.3 A外形寸法(幅 /奥行き)

278 × 95.6 mm質量 約 0.3 kg

仕様出力数 34 出力(D-sub 37 ピン (2)、D-sub 25 ピ

ン (1)、D-sub 9 ピン (1))出力信号 AES3-2003 およびAES-2id-1996(r2001)6.3

項に準拠の 24 ビットデジタルオーディオ信号外部リファレンスビデオ信号またはワードシンクに同期

出力レベル 2.7 Vp-p ± 20%以内(差動、110Ω終端時)

出力データ転送速度(サンプリングレート)6.144 Mbps(Fs=48 kHz)

付属品オペレーションアンドインストレーションガイド(1)

17 BNC AES/EBUアウトプットボード IKS-A6062

一般電源 DC12 V消費電流 0.14 A外形寸法(幅 /奥行き)

278 × 95.6 mm質量 約 0.3 kg

仕様出力数 17 出力(BNC 型)出力信号 外部リファレンスビデオ信号またはワー

ドシンクに同期したAES3-2003 およびAES-3id-1995 4 項に準拠の 24 ビットデジタルオーディオ信号

出力レベル 1 Vp-p ± 20%以内(75Ω終端時)出力データ転送速度(サンプリングレート)

6.144 Mbps(Fs=48 kHz)

付属品オペレーションアンドインストレーションガイド(1)

オーディオルーターをお使いの場合、バージョンによってAES/EBUオーディオ信号の遅延量が異なります。

V1.0、V1.01SRC OFFのとき:104 μs (5 word) SRC ONのとき:104 μs (5 word) +2.1 ms

V1.1以上SRC OFFのとき:146 μs (7 word) SRC ONのとき:146 μs (7 word) +2.1 msSRC: Sampling Rate Converter (IKS-A6015)

7 RS-422アウトプットボード IKS-RS6060

一般電源 DC12 V消費電流 0.1 A外形寸法(幅 /奥行き)

278 × 95.6 mm質量 約 0.3 kg

仕様信号数 7(D-sub 9 ピン)入出力信号 RS-422A 信号入出力データ転送速度

RS-422A 規格準拠信号伝達距離 1000 m

付属品オペレーションアンドインストレーションガイド(1)

17 タイムコードアウトプットボ-ド IKS-TC6060

一般電源 DC12 V消費電流 0.16 A外形寸法(幅/奥行き)

278 × 95.6 mm質量 約 0.4 kg

ご参考

主な仕様 39

Page 40: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

40

仕様出力数 17 出力(BNC型)出力インピーダンス

50Ω以下出力信号 SMPTE 12M-1999 の 8.6 項に定義されて

いる、電気的および機械的インターフェース特性に準拠したタイムコード信号(LTC)ただし 8.6.3 項は適用外

出力レベル 2 Vp-p ± 10%(1kΩ終端時)出力デ-タ転送速度

SMPTEモード:1/4 倍速 ~ 2 倍速(NTSC/PAL)(標準設定)

         高速転送モード:1/4 倍速 ~ 10 倍速(NTSC/PAL)

高速転送モード時は出力信号波形の傾斜が急峻となるために、SMPTE 12M-1999 の 8.6.1 項に定義された電気的特性を満足することはできませんので、上記規格の特性に適合した信号を出力したい場合は SMPTEモードでの使用を推奨します。

付属品オペレ-ションアンドインストレ-ションガイド(1)

ご注意

主な仕様

Page 41: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

English

B

To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.

THIS APPARATUS MUST BE EARTHED.

Afin de réduire les risques d’incendie ou d’électrocution, ne pas exposer cet appareil à la pluie ou à l’humidité.

Afin d’écarter tout risque d’électrocution, garder le coffret fermé. Ne confier l’entretien de l’appareil qu’à un personnel qualifié.

CET APPAREIL DOIT ÊTRE RELIÉ À LA TERRE.

Um die Gefahr von Bränden oder elektrischen Schlägen zu verringern, darf dieses Gerät nicht Regen oder Feuchtigkeit ausgesetzt werden.

Um einen elektrischen Schlag zu vermeiden, darf das Gehäuse nicht geöffnet werden. Überlassen Sie Wartungsarbeiten stets nur qualifiziertem Fachpersonal.

DIESES GERÄT MUSS GEERDET WERDEN.

For the customers in the USAThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.

All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept an interference received, including interference that may cause undesired operation.

WARNING: THIS WARNING IS APPLICABLE FOR USA ONLY.If used in USA, use the UL LISTED power cord specified below.DO NOT USE ANY OTHER POWER CORD.

Plug Cap Parallel blade with ground pin(NEMA 5-15P Configuration)

Cord Type SJT, three 16 or 18 AWG wiresLength Minimum 1.5m (4 ft. 11 in.), Less than 2.5 m

(8 ft. 3 in.)Rating Minimum 10A, 125V

Using this unit at a voltage other than 120V may require the use of a different line cord or attachment plug, or both.To reduce the risk of fire or electric shock, refer servicing to qualified service personnel.

WARNING: THIS WARNING IS APPLICABLE FOR OTHER COUNTRIES.1. Use the approved Power Cord (3-core mains lead) /

Appliance Connector / Plug with earthing-contacts that conforms to the safety regulations of each country if applicable.

2. Use the Power Cord (3-core mains lead) / Appliance Connector / Plug conforming to the proper ratings (Voltage, Ampere).

AVERTISSEMENT

WARNUNG

WARNING

This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

G

41

Page 42: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

42

If you have questions on the use of the above Power Cord / Appliance Connector / Plug, please consult a qualified service personnel.

AVERTISSEMENT:1. Utilisez un cordon d’alimentation (câble secteur à 3

fils)/fiche femelle/fiche mâle avec des contacts de mise à la terre conformes à la réglementation de sécurité locale applicable.

2. Utilisez un cordon d’alimentation (câble secteur à 3 fils)/fiche femelle/fiche mâle avec des caractéristiques nominales (tension, ampérage) appropriées.

Pour toute question sur l’utilisation du cordon d’alimentation/fiche femelle/fiche mâle ci-dessus, consultez un technicien du service après-vente qualifié.

WARNUNG:1. Verwenden Sie ein geprüftes Netzkabel (3-adriges

Stromkabel)/einen geprüften Geräteanschluss/einen geprüften Stecker mit Schutzkontakten entsprechend den Sicherheitsvorschriften, die im betreffenden Land gelten.

2. Verwenden Sie ein Netzkabel (3-adriges Stromkabel)/ einen Geräteanschluss/einen Stecker mit den geeigneten Anschlusswerten (Volt, Ampere).

Wenn Sie Fragen zur Verwendung von Netzkabel/Geräteanschluss/Stecker haben, wenden Sie sich bitte anqualifiziertes Kundendienstpersonal.

For customer in Canada This Class A digital apparatus complies with Canadian ICES-003.

Pour les utilisateurs au Canada Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

For the customers in EuropeThis product with the CE marking complies with both the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community.Compliance with these directives implies conformity to the following European standards:• EN60950-1: Product Safety (for IXS-6600/6700 only)• EN55103-1: Electromagnetic Interference (Emission)• EN55103-2: Electromagnetic Susceptibility (Immunity)This product is intended for use in the following Electromagnetic Environment: E4 (controlled EMC environment, ex. TV studio).

Pour les clients européensCe produit portant la marque CE est conforme à la fois à la Directive sur la compatibilité électromagnétique (EMC) (89/336/CEE) et à la Directive sur les basses tensions (73/23/

CEE) émises par la Commission de la Communauté Européenne.La conformité à ces directives implique la conformité aux normes européennes suivantes:• EN60950-1: Sécurité des produits (IXS-6600/6700

seulement)• EN55103-1: Interférences électromagnétiques (émission)• EN55103-2: Sensibilité électromagnétique (immunité)Ce produit est prévu pour être utilisé dans les environnements électromagnétiques suivant: E4 (environnement EMC contrôlé, ex. studio de télévision).

Für Kunden in EuropaDieses Produkt besitzt die CE-Kennzeichnung und erfüllt die EMV-Richtlinie (89/336/EWG) sowie die Niederspannungsrichtlinie (73/23/EWG) der EG-Kommission.Angewandte Normen:• EN60950-1: Sicherheitsbestimmungen (nur IXS-6600/

6700)• EN55103-1: Elektromagnetische Verträglichkeit

(Störaussendung)• EN55103-2: Elektromagnetische Verträglichkeit

(Störfestigkeit),für die folgenden elektromagnetischen Umgebungen: E4 (kontrollierter EMV-Bereich, z.B. Fernsehstudio)

Voor de klanten in Nederland• Gooi de batterij niet weg maar lever deze in als klein

chemisch afval (KCA).• Dit apparaat bevat een vast ingebouwde batterij die niet

vervangen hoeft te worden tijdens de levensduur van het apparaat.

• Raadpleeg uw leverancier indien de batterij toch vervangen moet worden. De batterij mag alleen vervangen worden door vakbekwaam servicepersoneel.

• Lever het apparaat aan het einde van de levensduur in voor recycling, de batterij zal dan op correcte wijze verwerkt worden.

For the Customers in Taiwan only

For the State of California, USA onlyPerchlorate Material - special handling may apply, Seewww.dtsc.ca.gov/hazardouswaste/perchloratePerchlorate Material : Lithium battery contains perchlorate.

Page 43: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

43Table of Contents

Table of Contents

The Integrated Routing System Manual Line-up ...............44Overview................................................................................44

Features of the IXS-6600/6700 Integrated Routing System......45IXS-6600/6700 System Products...............................................46Configuration Examples ............................................................50Control System of the IXS-6600/6700 Integrated Routing

System.............................................................................51Functions of the IXS-6600/6700 Integrated Routing System....51Functions of an S-BUS System .................................................52System Connection Example .....................................................53

Locations and Functions of Parts.......................................55IXS-6600 Integrated Routing System........................................55IXS-6700 Integrated Routing System........................................58Option Boards ............................................................................61

Status Indications.................................................................63Displayed Items .........................................................................63Functions of the Operation Buttons ...........................................64Basic Operations ........................................................................64Confirming the Status of the Machine.......................................64Adjusting the Contrast of the Display Window.........................64

Error Indications and Countermeasures ............................65Status Indicators.........................................................................65Error Status ................................................................................66

Supplied Software ................................................................68Installing BZR-21 ......................................................................68

Specifications .......................................................................69IXS-6700 Integrated Routing System........................................69IXS-6600 Integrated Routing System........................................70Optional Boards .........................................................................71

Page 44: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

44

The Integrated Routing System Manual Line-up

The following manuals have been prepared to thoroughly explain this Integrated Routing System. Under the directions provided in this manual and in correlation with your needs, refer to the manual that suits your purpose best.

Operation Manual (this manual, on a supplied CD-ROM)This manual supplies information related to a simple outline of the integrated routing system, connection examples, an explanation of each part, and the specifications.

System Setup Manual (on a supplied CD-ROM)This manual supplies information related to the initial settings and verification of operation. It also supplies information about the principal equipment in a integrated routing system.

Installation Manual (on a supplied CD-ROM)This manual supplies information related to the maintenance and initial service to the integrated routing system such as board replacement.

Maintenance Manual (option)This manual supplies information related to the servicing of each parts level (i.e. the essential points for adjustment, mount diagrams, circuit diagrams, and a detailed parts list). Ask the Sony dealer where you purchased this integrated routing system for details about obtaining this manual.

Protocol Manual (option)Supplies information related to the protocol used to control this integrated routing system.The following manual is available for your reference about the protocol supported by this integrated routing system:S-BUS remote terminal control protocol: S-BUS

PROTOCOL AND COMMAND SPECIFICATIONSAsk the Sony dealer where you purchased this integrated routing system for details about obtaining this manual.

Overview

The IXS-6600/6700 Integrated Routing System handles AES/EBU digital audio signals, digital video (SD and HD) signals, and time code signals as well as data (RS-422A signals).By mounting various optional boards in the IXS-6600/6700 enclosure model, you can configure it to handle a wide array of signals.

For details, see “IXS-6600/6700 System Products” on page 46.

Actual signal switching can be controlled, using an external control unit, such as the optional BKS-R1617/R1618/R3216/R3219/R3220 Routing Switcher Control Unit.

For details, see “Control System of the IXS-6600/6700 Integrated Routing System” on page 51.

Some of signal-switching operations can be controlled from a PC if the BZR-21 Routing Switcher Remote Control Software (supplied) is installed on the PC connected with the IXS-6600/6700, using Ethernet or RS-232C.

For details, see “Supplied Software” on page 68.

To operate this system, various settings (table data creation and system settings) must be made beforehand, using terminal emulator software on the PC.

For details, refer to the System Setup Manual (supplied).

• For the HDTV SDI signal line, use the HD/SD-type optional boards from input through output, as shown below:Processor board: IKS-V6050MInput board: IKS-V6010MOutput board: IKS-V6060M

• For example, even if the HD/SD Digital Video Output Board is used for output, when a processor board dedicated to the SDTV SDI signals (SD Video Router Processor) is used for processing, HDTV SDI signals are not output.

• When the RS-422 boards are to be mounted, the slot number for the IKS-RS6010 Input Board and that for the IKS-RS6060 Output Board must be identical, as they are handled as a pair. For example, if the input board is installed in Slot 3 for input boards, the output board must be also installed in Slot 3 for output boards.

• The 540 Mbps SDTV SDI signal is not handled by the SD Digital Video Board. Only a digital video board that can handle HD/SD signals can support this signal.

Notes

The Integrated Routing System Manual Line-up

Page 45: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

For details, refer to the Installation Manual (supplied).

Features of the IXS-6600/6700 Integrated Routing System

Selectable two types of chassisFor the IXS-6700, when digital video signals are handled, from a minimum of 16 inputs × 17 outputs to a maximum of 128 inputs × 136 outputs can be installed in an EIA 8RU chassis. For the IXS-6600, a minimum of 16 inputs × 17 outputs to a maximum of 64 inputs × 68 outputs can be installed in an EIA 4RU chassis.

Multiple signal formats handled in a single chassisThe IXS-6600/6700 can handle the following signals:• Video: HDTV SDI signal• Video: SDTV SDI signal• Audio: AES/EBU digital audio signal• Data: RS-422A signal• Time code: LTC signalMultiple signal-format boards can be mounted in a single chassis for simultaneous operation, which enables reducing the number of devices required for routing to one.

Flexible input/output configurationThe video signals can be expanded in units of 16 inputs and 17 outputs.The digital audio (balanced) signals can be expanded in units of 32 inputs and 34 outputs.The digital audio (unbalanced) signals and time code (LTC) signals can be expanded in units of 16 inputs and 17 outputs.Data signals can be expanded in units of 7 inputs and 7 outputs, as 7 inputs and 7 outputs are handled as a pair.

Multiple-bit-rate video signals supportedWith the use of optional boards supporting multiple-bit-rate video signals, SDTV SDI signals (143 Mbps, 177 Mbps, 270 Mbps, 360 Mbps, 540 Mbps), HDTV SDI signals (1.485 Gbps, 1.485/1.001 Gbps), and DVB-ASI 270 Mbps signals can be handled. These rates can be independently selected for each input/output.

Supporting audio asynchronous systemIf an SRC (Sampling Rate Converter) board is mounted, asynchronous digital audio input signals can be supported.

Audio matrix size double that for video signalsThe TDM (Time Division Multiplexing) technique enables matrix size (256 × 272) for the AES/EBU digital audio signals (balanced) double that for video signals.

Supporting Dolby E (compressed audio)

Linear PCM audio functions supported• Soft Switching (V1.10 or later)

Slow transition of audio data toward 0 at a switching point reduces popping and clicking sounds in the audio output.

Soft Switching does not support Dolby E.

• SRC (Sampling Rate Converter) ON/OFF functionActivation/deactivation of the Sampling Rate Converter function can be set for each AES/EBU digital audio input signal.

For details, refer to the System Setup Manual (supplied).

• SRC (Sampling Rate Converter) Matched Phase ModeA phase difference between adjacent channels can be maintained for the audio signals input to the Sampling Rate Converter.

This function is effective for audio channels on a single input board, but not for audio channels on multiple input boards.

For details, refer to the System Setup Manual (supplied).

• The AES/EBU format signals have stereo channels, and audio sources for those two channels can be output in the following four manners in addition to stereo (default): Lboth, Rboth, Swap, and Mix(L+R). (V1.10 or later)

For the ancillary data for the AES/EBU format signals (channel status, user data, and validity flag), Lboth, Rboth, Swap, and Mix(L+R) do not function.

Linear PCM/Compressed audio functions supported• Channel status regeneration (V1.10 or later)

When AES/EBU signals are switched, a CRC (Cyclic Redundancy Check) error may be generated in the device to which the signal from this unit is input, because the data within the block become inconsistent with the CRC values. To prevent muting caused by such a CRC error, regeneration of channel status is performed.

Supporting RS-422A physical assignment

Redundant CPU/redundant power units as standard equipmentThe control board and power units for backups, which are essential for highly reliable professional broadcasting equipment, are provided as standard equipment.

Note

Note

Note

45Overview

Page 46: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

46

Two Ethernet connectors for two networksTwo Ethernet connectors are provided for one chassis of the IXS-6600/6700, and a different IP address is assigned to each of them, enabling redundancy of two networks.

Web settings (V2.0 or higher)Settings for the primary station and secondary stations are enabled from the Web browser.Applicable devicesPrimary station: IXS-6600/IXS-6700 (V2.0 or higher)Secondary Station: IXS-6600/IXS-6700 (V2.0 or higher), HDS-X5800(Applicable browser: Internet Explorer 6)

For details, refer to the System Setup Manual supplied.

Equipped with two reference-signal systemsThe IXS-6600/6700 is equipped with two reference systems A and B for the video reference input, which can be selected for each output block. For example, the house sync of a broadcast station and a reference signal that has a different phase/frequency from that of the house sync can be used in a single chassis as the references for different matrixes.

Supporting the word sync signalThe IXS-6700 is provided with two systems of the audio word sync signal input, and the IXS-6600 is provided with one.

Provided with three systems of the S-BUS controlThe IXS-6700 is provided with independent three systems and four channels (A, B1, B2, C) of the S-BUS connectors, and the IXS-6600 is provided with independent three systems and three channels (A, B, C) of the S-BUS connectors. In each S-BUS control system, all routing switchers and control units that are to be controlled are connected using one coaxial cable.

Supporting BZR-IF830 (4093 × 4093) Control SoftwareS-BUS space can be expanded up to 4093 × 4093, by connecting the HKSP-R80 Routing Switcher Controller for which BZR-IF830 has been installed to this unit through the Ethernet and S-BUS data link. Within the expanded S-BUS space, several S-BUS spaces can be controlled.

IXS-6600/6700 System Products

Chassis

IXS-6700 Integrated Routing SystemThe size of the chassis of the IXS-6700 is EIA 8RU. The maximum matrix size for a single-format signal is as shown in the table below:

The unit essentially consists of four power units and two control CPU boards, both having redundant structure.The optional boards described later can be attached.

IXS-6600 Integrated Routing SystemThe size of the chassis of the IXS-6600 is EIA 4RU. The maximum matrix size for a single-format signal is as shown in the following table below:

The unit essentially consists of two power units and two control CPU boards, both having redundant structure.The optional boards described later can be attached.

Matrix boards (option)

IKS-6030M Matrix BoardThis is a matrix board of 128 inputs × 68 outputs. Up to two matrix boards can be attached to the IXS-6700, with maximum expansion to 128 inputs × 136 outputs possible. When this board is attached to the IXS-6600, the matrix size becomes 64 inputs × 68 outputs.When audio signals are handled, the maximum matrix size becomes 256 inputs × 272 outputs for the IXS-6700 or 128 inputs × 136 outputs for the IXS-6600.

Signal Maximum matrix size

Video 128 inputs × 136 outputs

AES/EBU digital audio (balanced)

256 inputs × 272 outputs

AES/EBU digital audio (unbalanced)

128 inputs × 136 outputs

Time code (unbalanced) 128 inputs × 136 outputs

RS-422A 112 ports

Signal Maximum matrix size

Video 64 inputs × 68 outputs

AES/EBU digital audio (balanced)

128 inputs × 136 outputs

AES/EBU digital audio (unbalanced)

64 inputs × 68 outputs

Time code (unbalanced) 64 inputs × 68 outputs

RS-422A 56 ports

Overview

Page 47: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

Main Processor Board (option)The following three main processor boards can be mounted in combination:• IKS-V6050M HD/SD Video Router Processor Board• IKS-V6050SD SD Video Router Processor Board• IKS-A6050 Audio/Data Router Processor Board

IKS-V6050M HD/SD Video Router Processor BoardThis is a router processor board that handles 34 HD/SD digital video signals. It can handle SDTV SDI signal rates (143 Mbps, 177 Mbps, 270 Mbps, 360 Mbps, 540 Mbps), HDTV SDI signal rates (1.485 Gbps, 1.485/1.001 Gbps), and DVB-ASI 270 Mbps signals.At the later stage of one HD/SD video router processor board, up to two output boards can be attached. When four HD/SD Video Router Processor Boards are attached to the IXS-6700, 136 video signals can be output. When two HD/SD Video Router Processor Boards are attached to the IXS-6600, 68 video signals can be output.For output boards, HD/SD Digital Video Output Boards, SD Digital Video Output Boards, and Time Code Output Boards can be used in combination.

The HD/SD Digital Video Output Board is required in order to obtain HDTV SDI signal output.

IKS-V6050SD SD Video Router Processor BoardThis is a router processor board that handles 34 SD digital video signals. It can handle SDTV SDI signal rates (143 Mbps, 177 Mbps, 270 Mbps, 360 Mbps) and DVB-ASI 270 Mbps signals.At the later stage of one SD Video Router Processor Board, up to two output boards for digital video signals or time code signals can be attached. When four SD Video Router Processor Boards are attached to the IXS-6700, 136 video signals can be output. When two SD Video Router Processor Boards are attached to the IXS-6600, 68 video signals can be output.

HDTV SDI signal output cannot be obtained even if the HD/SD Digital Video Output Board is attached.

IKS-A6050 Audio/Data Router Processor BoardThis is a router processor board that handles 68 AES/EBU audio signals, 28 data signals (RS-422A), and 34 time code signals.At the later stage of one Audio/Data Router Processor Board, up to two output boards can be attached. For output boards, AES/EBU Audio Output Boards, RS-422A Output Boards, and Time Code Output Boards can be used in combination.

Input Boards (option)

IKS-V6010M 16 HD/SD Digital Video Input BoardThis is an input board that handles 16 HD/SD digital video signals. The input connectors can support SDTV SDI signal rates (143 Mbps, 177 Mbps, 270 Mbps, 360 Mbps, 540 Mbps), HDTV SDI signal rates (1.485 Gbps, 1.485/1.001 Gbps), and DVB-ASI 270 Mbps signals.For the IXS-6700, the number of inputs can be expanded from 16 to 128, in units of 16.For the IXS-6600, the number of inputs can be expanded from 16 to 64, in units of 16.

IKS-V6010SD 16 SD Digital Video Input BoardThis is an input board that handles 16 SD digital video signals. The input connectors can support SDTV SDI signal rates (143 Mbps, 177 Mbps, 270 Mbps, 360 Mbps) and DVB-ASI 270 Mbps signals.For the IXS-6700, the number of inputs can be expanded from 16 to 128, in units of 16.

Model name of optional board

Product nameMaximum quantity to mount

IXS-6600 IXS-6700

IKS-6030M Matrix Board 1 2

Model name of optional board

Product nameMaximum quantity to mount

IXS-6600 IXS-6700

IKS-V6050M HD/SD Video Router Processor Board

2 4

IKS-V6050SD SD Video Router Processor Board

IKS-A6050 Audio/Data Router Processor Board

Note

Note

Model name of optional board

Product nameMaximum quantity to mount

IXS-6600 IXS-6700

IKS-V6010M 16 HD/SD Digital Video Input Board

4 8

IKS-V6010SD 16 SD Digital Video Input Board

IKS-A6011 32 D-sub AES/EBU (balanced) Input Board

IKS-A6012 16 BNC AES/EBU (unbalanced) Input Board

IKS-A6015 32 Sampling Rate Converter Board

IKS-RS6010 7 RS-422 Input Board

IKS-TC6010 16 Time Code Input Board

47Overview

Page 48: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

48

For the IXS-6600, the number of inputs can be expanded from 16 to 64, in units of 16.

The IKS-V6010SD does not support a 540-Mbps SDTV SDI signal rate.

IKS-A6011 32 D-sub AES/EBU Input BoardThis is an input board that handles 32 AES/EBU audio (balanced) signals. It supports 48-kHz sampling frequency synchronized with the reference word sync signal of this unit.For the IXS-6700, the number of inputs can be expanded from 32 to 256, in units of 32.For the IXS-6600, the number of inputs can be expanded from 32 to 128, in units of 32.

The AES/EBU Digital Audio Input Board does not support asynchronous AES/EBU signals. To handle asynchronous AES/EBU signals, attach the IKS-A6015 32 Sampling Rate Converter Board on this board.

IKS-A6012 16 BNC AES/EBU Input BoardThis is an input board that handles 16 AES/EBU audio (unbalanced) signals. It supports 48-kHz sampling frequency synchronized with the reference word sync signal of this unit.For the IXS-6700, the number of inputs can be expanded from 16 to 128, in units of 16.For the IXS-6600, the number of inputs can be expanded from 16 to 64, in units of 16.

The AES/EBU Digital Audio Input Board does not support asynchronous AES/EBU signals. To handle asynchronous AES/EBU signals, attach the IKS-A6015 32 Sampling Rate Converter Board on this board.

IKS-A6015 32 Sampling Rate Converter BoardThis is a board that handles 32 sampling rate conversion. Attaching this board on the IKS-A6011 32 D-sub AES/EBU Input Board or IKS-A6012 16 BNC AES/EBU Input Board enables handling of asynchronous digital input signals.

IKS-RS6010 7 RS-422 Input BoardThis is an input board that handles 7 data (RS-422A). It only supports a 38.4-kbps signal rate. As the RS-422 input and output boards are handled as a pair, the input/output size can be expanded in units of 7 inputs and 7 outputs.The maximum number of RS-422 ports for the IXS-6700 is 112, and that for the IXS-6600 is 56.

Use the RS-422 Input and Output Boards as a pair. When the RS-422 boards (IKS-RS6010 Input Board and IKS-

RS6060 Output Board) are to be installed, the slot number for the input board and that for the output board must be identical. For example, if the input board is installed in Slot 3 for input boards, the output board must be also installed in Slot 3 for output boards.

For details, refer to the Installation Manual (supplied).

IKS-TC6010 16 Time Code Input BoardThis is an input board that handles 16 time code (LTC) signals. For the IXS-6700, the number of inputs can be expanded from 16 to 128, in units of 16.For the IXS-6600, the number of inputs can be expanded from 16 to 64, in units of 16.

Output Board (option)

IKS-V6060M 17 HD/SD Digital Video Output BoardThis is an output board that handles 17 HD/SD digital video signals. It supports SDTV SDI signal rates (143 Mbps, 177 Mbps, 270 Mbps, 360 Mbps, 540 Mbps), HDTV SDI signal rates (1.485 Gbps, 1.485/1.001 Gbps), and DVB-ASI 270 Mbps signals.For the IXS-6700, the number of outputs can be expanded from 17 to 136, in units of 17.For the IXS-6600, the number of outputs can be expanded from 17 to 68, in units of 17.

IKS-V6060SD 17 SD Digital Video Output BoardThis is an output board that handles 17 SD digital video signals. It supports SDTV SDI signal rates (143 Mbps, 177 Mbps, 270 Mbps, 360 Mbps) and DVB-ASI 270 Mbps signals.For the IXS-6700, the number of outputs can be expanded from 17 to 136, in units of 17.For the IXS-6600, the number of outputs can be expanded from 17 to 68, in units of 17.

Note

Note

Note

Note

Model name of optional board

Product nameMaximum quantity to mount

IXS-6600 IXS-6700

IKS-V6060M 17 HD/SD Digital Video Output Board

4 8

IKS-V6060SD 17 SD Digital Video Output Board

IKS-A6061 34 D-sub AES/EBU (balanced) Output Board

IKS-A6062 17 BNC AES/EBU (unbalanced) Output Board

IKS-RS6060 7 RS-422 Output Board

IKS-TC6060 17 Time Code Output Board

Overview

Page 49: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

The IKS-V6060SD does not support a 540-Mbps SDTV SDI signal rate.

IKS-A6061 34 D-sub AES/EBU Output BoardThis is an output board that handles 34 AES/EBU audio signals (balanced). It supports 48-kHz sampling frequency synchronized with the reference word sync signal.For the IXS-6700, the number of outputs can be expanded from 34 to 272, in units of 34.For the IXS-6600, the number of outputs can be expanded from 34 to 136, in units of 34.

IKS-A6062 17 BNC AES/EBU Output BoardThis is an output board that handles 17 AES/EBU audio signals (unbalanced). It supports 48-kHz sampling frequency synchronized with the reference word sync signal.For the IXS-6700, the number of outputs can be expanded from 17 to 136, in units of 17.For the IXS-6600, the number of outputs can be expanded from 17 to 68, in units of 17.

IKS-RS6060 7 RS-422 Output BoardThis is an output board that handles 7 data (RS-422A). It only supports a 38.4-kbps signal rate. As the RS-422 input and output boards are handled as a pair, the input/output size can be expanded in units of 7 inputs and 7 outputs.The maximum number of RS-422 ports for the IXS-6700 is 112, and that for the IXS-6600 is 56.

Use the RS-422 Input and Output Boards as a pair. When the RS-422 boards (IKS-RS6010 Input Board and IKS-RS6060 Output Board) are to be installed, the slot number for the input board and that for the output board must be identical. For example, if the input board is installed in Slot 3 for input boards, the output board must be also installed in Slot 3 for output boards.

For details, refer to the Installation Manual (supplied).

IKS-TC6060 17 Time Code Output BoardThis is an output board that handles 17 time code (LTC) signals. For the IXS-6700, the number of inputs can be expanded from 17 to 136, in units of 17.For the IXS-6600, the number of inputs can be expanded from 17 to 68, in units of 17.This board can be used with any processor board of IKS-A6050, IKS-V6050M, or IKS-V6050SD.

Note

Note

49Overview

Page 50: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

50

Configuration Examples

Hybrid configuration examples for the IXS-6600

With the above configuration, several routing switchers, each of which can handle a different signal format, can be configurated within a single chassis enclosure.The crosspoint size for each signal format is as follows:

Hybrid configuration examples for the IXS-6700

17

17

34

7

16 16 32 7

Matrix Board 128 × 68

HD/SD Video Router Processor Board

17 HD/SD Digital Video Output Board

Audio/Data Router Processor Board

16 H

D/SD D

igita

l Vid

eo

Inpu

t Boa

rd16

SD D

igita

l Vid

eo

Inpu

t Boa

rd32

D-s

ub A

ES/EBU

(bal

ance

d) In

put B

oard

7 RS-4

22 In

put B

oard

17 SD Digital Video Output Board

34 D-sub AES/EBU (balanced) Output Board

7 RS-422 Output Board

Mother board

Number of inputs

Produ

ct n

ame

Number of outputs Product name

Signal format Matrix size

SDI router section 32 × 34 (of which, 16 × 17 for HD SDI)

Digital audio router section 32 × 34

RS-422A router section 14 ports

16

17

17

17

17

34

34

7

7

16 16 16 32 32 7 7

Matrix Board 128 × 68

HD/SD Video Router Processor Board

Audio/Data Router Processor Board

17 HD/SD Digital Video Output Board

SD Video Router Processor Board

Audio/Data Router Processor Board

Matrix Board 128 × 68

16 H

D/SD D

igita

l Vid

eo

Inpu

t Boa

rd16

SD D

igita

l Vid

eo

Inpu

t Boa

rd32

D-s

ub A

ES/EBU

(bal

ance

d) In

put B

oard

7 RS-4

22 In

put B

oard

17 SD Digital Video Output Board

34 D-sub AES/EBU (balanced) Output Board

7 RS-422 Output Board

Mother board

Number of inputs

Produ

ct n

ame

Number of outputs Product name

Overview

Page 51: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

With the configuration mentioned before, several routing switchers, each of which can handle a different signal format, can be configurated within a single chassis enclosure.The crosspoint size for each signal format is as shown below:

Control System of the IXS-6600/6700 Integrated Routing System

In the IXS-6600/6700 Integrated Routing System, a remote control panel (routing switcher control unit) controls the signal switching in accordance with the settings of a terminal emulator on a PC. A supplied BZR-21 Routing Switcher Remote Control Software (GUI software) can control basic crosspoint switching on a PC.There are four types of control available for you to control the routing system: S-BUS protocol, which is used through the BNC-type REMOTE 1 connectors; RS-422A protocol, which is used through the D-sub 9-pin REMOTE 2 connectors; RS-232C protocol, which is used through the D-sub 9-pin REMOTE 3 connector; and Ethernet protocol, which is used through the NETWORK connectors.Simultaneous use of four protocols is also possible.

Control using S-BUS protocolS-BUS is a protocol developed by Sony for control of a digital routing switcher system. This protocol enables communication between multiple routing switchers and remote control panels (routing switcher control units) using one coaxial cable. A combined total of 254 routing switchers, remote control panels and equivalent devices can be controlled using S-BUS protocol.The IXS-6600/6700 has the capability to convert RS-422A commands to S-BUS commands, enabling S-BUS control through the D-sub 9-pin REMOTE 2 connector.

Control using RS-422A protocolThe IXS-6600/6700 has the capability to convert RS-422A commands to S-BUS commands, enabling S-BUS control from the D-sub 9-pin REMOTE 2 connector. The mode that controls signals in their original form using RS-422A commands is known as Direct mode, and the mode that converts RS-422A commands to S-BUS commands is known as S-BUS Convert mode. S-BUS convert mode can control up to 1024 lines, eight levels, however the response speed is slower than in Direct mode. Also, the items that can be controlled in S-BUS Convert mode are limited to those that can be controlled in Direct mode.

When S-BUS remote is set to the primary station, the mode is fixed to S-BUS Convert mode. When set to the secondary station, it is fixed to Direct mode.

Simultaneous control of multiple signals with the level settingTo simultaneously handle several types of signals, each type of signal requires a different routing switcher. These are known as levels. For example, a VTR requires video, audio, time code, and remote control signals for recording. To switch these signals, these signals require video, audio, time code, and remote routing switchers respectively. You can set a maximum of sixteen levels and different input signal numbers on each level in order to simultaneously control these levels.

Functions of the IXS-6600/6700 Integrated Routing System

The IXS-6600/6700 Integrated Routing System is equipped with the following functions:

Designated input and output line protect functionThis function prohibits switching of protected output signals from other remote control panels (routing switcher control units) (protect function) and prohibits switching from other control panels by hiding the input signals from all control panels (secret function).

Crosspoint disable functionFor every output signal, you can limit the input signals available for selection so that any particular input signals can be output to the specified output lines.

Password functionYou can enter a password to prevent unauthorized users from accessing the system.

Name setting functionYou can set names for each input and output connector in order to distinguish among the connected signals.Two methods are available for setting the names; either enter the device name and number (i.e. name of the VTR, camera, etc.), for example VTR 1, or a description using up to 16 characters. You can display the name on the optional BKS-R1617/R1618/R3216/R3219/R3220 control units.

Virtual mapping functionYou can set crosspoints on a virtual matrix.

Free assignment functionYou can assign a different connector number to a connector name on each level.

Signal format Matrix size

SDI router section 64 × 68 (of which, 16 × 17 for HD SDI)

Digital audio router section 64 × 68

RS-422A router section 28 ports

51Overview

Page 52: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

52

Tie line functionYou can enable the system to automatically select the signal line that connects up to three routing switchers.

Phantom functionYou can switch several crosspoints at the same time.

Self-diagnosis functionInformation about whether an error has occurred or not can be displayed by the front-panel status indicators or on the terminal emulator connected to the primary station. The information can also be output to the ALARM connector in parallel.

For details, refer to the System Setup Manual (supplied).

Functions of an S-BUS System

An S-BUS control system transmits the control signals among several routing switchers and remote control panels (routing switcher control units) that are connected with one coaxial cable. In an S-BUS control system, one switcher is designated as the primary station which controls the entire system, and the remaining switchers and remote control panels are designated as secondary stations. Signal transmission between the secondary stations is controlled by the primary station.

The S-BUS control system has the following features.• LAN (Local Area Network) type control signal

transmission using a single 75Ω coaxial cable.• Possible extension of the coaxial cable up to 500 meters

when a BELDEN 8281 or equivalent cable is used.• Possible connection and disconnection of a switcher or

remote control panel to the S-BUS line during normal operations without turning the power off.

• Control of multiple S-BUS lines and up to 254 switchers and remote control panels (including the primary station) from the routing switcher designated as the primary station.

• Possible connection of a maximum of 128 routing switchers and remote control panels to one S-BUS line.

• Display of the errors detected through the self-diagnosis function on the PC (terminal emulator) connected to the primary station on the S-BUS line.

• Storage and future recovery of the settings (system settings and table data) made with the PC (terminal emulator) and the crosspoint data in/from a computer using the supplied BZR-20 Routing Switcher Data Backup Software.

Overview

Page 53: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

System Connection Example

Major system componentsThis system are composed with S-BUS data link connected with 75Ω coaxial cables as its core.

The major components of the S-BUS data link are listed below.

Notes on connections• Set the P/S switch1) on the internal CPU board of the

integrated routing system to be used for the primary station to P.

• Set the P/S switch1) on the internal CPU board of the routing switcher to be used for a secondary station to S.

• A maximum of 128 routing switchers and remote control panels can be connected as secondary stations to one S-BUS line.

• The coaxial cable can be extended up to 500 meters when a BELDEN 8281 or equivalent cable is used.

• Be sure to terminate the T-bridge attached to the last unit of the S-BUS line and the unused REMOTE 1 connectors of each switcher with 75Ω terminators.

• Only one of the REMOTE 1 connectors can be used on the routing switcher used for a secondary station.

1) S1203-3 P/S switch on the CA-65 board for the IXS-6600/6700

How to use the T-bridge (type B)A T-bridge of type B is supplied with the IXS-6600/6700. To use it, connect as follows to coaxial cables shorter than 50 cm (19

3/4 inches):

Configuration of an S-BUS data link

Description on the S-BUS data link

Equipment Quantity Function

Primary station

System controller

Routing switcher controller HKSP-R80 1 Communication control over the entire S-BUS data link. Simultaneously operable as a secondary station.Routing

switcherIntegrated routing system IXS-6600/6700

Routing switcher processor HDS-X5800

Secondary stations

Routing switcher

Routing switcher processor HDS-X5800 253 max. Communication control in each unit. Each operates according to instructions from the primary station.

Integrated routing system IXS-6600/6700

Remote control panel (Routing switcher control unit)

X-Y control unit BKS-R3220

32-button control unit BKS-R3219

Universal control unit BKS-R1617

16-button control unit BKS-R1618

8-destination control unit BKS-R3216

Terminal Terminal emulator General PC 1 Various system settings.Indication and control of errors that are generated in the S-BUS line.

REMOTE 1 connector (BNC, female)

T-bridge (type B)

BELDEN 8281 cable (less than 50 cm or 19 3/4 inches) or equivalent

53Overview

Page 54: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

54

Connection exampleThe following diagram shows the configuration of an S-BUS data link with the IXS-6700 as the primary station. This system cannot control the monitor S-BUS line.

Network A

RE

MO

TE

1 A

RE

MO

TE

1 C

RE

MO

TE

1 B

2

RE

MO

TE

1 B

1

Network B

Terminal Terminal

PC (Terminal emulator) PC (Terminal emulator)

: S-BUS

: Signal Line

: Ethernet

: T Bridge (A)

: T Bridge (B)

: 75Ω Terminator

: Matrix LevelPrimary Station Level 1

Integrated Routing System IXS-6700 (P)

Ethernet Hub

Video

Audio Channel 1/2

Audio Channel 3/4

Time Code

Destination VTR

Video

Source VTR

Secondary Station Level 2

Audio Routing Switcher (S) a)

Level 3

Audio Routing Switcher (S) a)

Level 4

Time Code Routing Switcher (S) a)

Level 8

Routing Switcher (S) a)

Audio Channel 1/2

Audio Channel 3/4

Time Code

128 max.

16 max.

Remote Control Panel

Remote Control Panel

Remote Control Panel

Subnet Controller

Subnet Controller

Remote Control Panel

Remote Control Panel

Third Station

Display Unit

Display Unit

Display Unit

a) (S) indicates the secondary station. Assign station ID from 2 to 254 to a secondary station which is not overlapping between units.

Display Unit

Overview

Page 55: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

Locations and Functions of Parts

IXS-6600 Integrated Routing System

Front panel

a POWER switchesTo turn the power on and off. Power units A and B back up each other. Be sure to set all the two switches to ON.

b POWER indicatorsThese light when power is supplied to the corresponding power units. The indicators are lit in green when operations are normal.If a fan in a power unit stops, the corresponding indicator will light in red.

It is not a problem that the POWER indicators may momentarily flash when the power is turned on, nor that one of the POWER switches is set to OFF with both the POWER switches set to ON while the corresponding POWER indicator may still be lit in red.If you set either the POWER switch to OFF when both the POWER switches are set to ON and soon set it to ON again, the POWER indicator for the power unit whose POWER switch is set to OFF and ON again may remain lit in red. In such a case, set the POWER switch for the power unit whose POWER indicator is lit in red to OFF, wait for

about 20 seconds until the indicator goes out, then set that POWER switch to ON again.If you wish to set the POWER switch or breaker to OFF after setting all the POWER switches to ON, wait for more than 20 seconds before setting it to OFF.

c Display windowShows the current status of the unit.

For details on errors, see “Status Indications” on page 63.

d Status indicatorsThese indicate the status of the unit by the color of the indicators and whether they are lit. The indicators are off or lit in green when the power is on and operations are normal. When an error occurs, the indicators light in red.

For details on errors, see “Error Indications and Countermeasures” on page 65.

e Operation buttonsSwitches the display in the display window.

For details on errors, see “Status Indications” on page 63.

POWER A

POWER B

INTEGRATED ROUTING SYSTEM IXS-6600MENU ENTERCANCEL

aPOWER switches

bPOWER indicators

dStatus indicators

eOperation buttons

cDisplay window

Note

55Locations and Functions of Parts

Page 56: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

56

Rear panel

a Output panel slotsFor the optional Output Boards.

For details, see “IXS-6600/6700 System Products” on page 46.

b Input panel slotsFor the optional Input Boards.

For details, see “IXS-6600/6700 System Products” on page 46.

c REMOTE 3 connector (D-sub 9-pin)If the switcher is used as the primary station1) (set the S1203-3 P/S switch on the CA-65 board to P), connect the terminal emulator to make the settings required for system operations.Use the D-sub 9-pin connectors with inch screws for connections.

If you are using the REMOTE 3 connector, set the S1203-3 P/S switch on the CA-65 board to the P position.

For further details, refer to the Installation Manual (supplied).

1) Remote control operations via S-BUS protocol consist of a data link constructed using a single coaxial cable link. Several pieces of equipment (i.e. routing switchers, remote control panel (routing switcher control unit), etc.) are connected to this data link for data transmission in time-sharing mode. One of the connected switchers is used as the primary

station that manages the use of the data link, while the other equipment is used as secondary stations which follow directions from the primary station. The response speed may slow down due to the number of secondary stations.

d REMOTE 2 connector (D-sub 9-pin)Connect an external control unit using a 9-pin remote control cable for use via the RS-422A interface.When the unit is specified for the primary station (set the S1203-3 P/S switch on the CA-65 board to P), S-BUS Convert mode is selected and S-BUS control via the REMOTE 2 connector is enabled.Use the D-sub 9-pin connectors with millimeter screws for connections.

For details, refer to the System Setup Manual (supplied).

e REMOTE 1 connectors (BNC type)There are three connectors for three signals, A, B, and C.Connect the remote control panels (routing switcher control units) and routing switchers using a single coaxial cable to control the system via S-BUS protocol. When you use this switcher as the primary station (set the S1203-3 P/S switch on the CA-65 board to P), a maximum of 253 remote control panels and routing switchers can be connected via these three connectors.When you use this switcher as a secondary station (set the S1203-3 P/S switch on the CA-65 board to S), connect an S-BUS link to one of the connectors using the supplied T-bridge (type B).

OUT1

OUT2

IN1

IN2

OUT3

OUT4

IN3

IN4

A

REMOTE 1A

REFINA

75ΩON

OFF

REMOTE 1B

REFINB

75ΩON

OFF

REMOTE 1C

WORDSYNC

IN75ΩON

OFF

TC IN

NETWORK

REMOTE 2

REMOTE 3

REMOTE 2/ALARM

B

B AU

- AC IN

aOutput panel slots

b Input panel slots

dREMOTE 2 connector

eREMOTE 1 connectors

fREF IN connectors and 75Ω termination switch

cREMOTE 3 connector

gWORD SYNC IN connector and 75Ω termination switch

hTC IN connectoriREMOTE 2/ALARM

connector

jNETWORK connectors

kAC IN receptacles

lU (signal ground) terminal

Note

Locations and

Functions of Parts
Page 57: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

For details, see “System Connection Example” on page 53.

Put the supplied 75Ω terminator(s) on the unused connector(s) regardless whether it is the primary station or secondary station.

f REF IN (reference input) connectors (BNC type) and 75Ω termination switch

There are two connectors for two signals (A and B).The connectors accept analog reference video signals (black burst compatible with CCIR624 standards or tri-level sync for HDTV).

75Ω termination switchFor selecting the input impedanceON: The input signal is terminated with 75 ohms.OFF: The input signal is terminated with high impedance. If an external sync signal is used in loop-through configuration, use this position.

If you wish to synchronize signal switching with a reference video signal, set the timing of signal switching (odd or even field) and select reference video signal A or B on the PC (terminal emulator).

For further details, refer to the System Setup Manual (supplied).

g WORD SYNC IN connector (BNC type) and 75Ω termination switch

The connector accepts an audio word sync signal.

75Ω termination switchFor selecting the input impedanceON: The input signal is terminated with 75 ohms.OFF: The input signal is terminated with high impedance. If an external sync signal is used in loop-through configuration, use this position.

h TC IN (time code input) connector (BNC type)The connector accepts time code signal.

i REMOTE 2/ALARM connector (D-sub 9-pin)Supplies the current status of the unit. This also functions as signal B of the REMOTE 2 connector.Use the D-sub 9-pin connectors with millimeter screws for connections.

For details, see “Specifications” on page 69 and refer to the Installation Manual and System Setup Manual (supplied).

j NETWORK connectors (modular jacks)There are two connectors for 100BASE-TX communications for signals A and B.Connect to the Ethernet connector on the PC in which the supplied BZR-20/21 has been installed.

For safety, do not connect the connector for peripheral device wiring that might have excessive voltage to the following ports.• NETWORK A connector• NETWORK B connectorFollow the instructions for the above ports.

k AC IN (AC power input) receptaclesThere are a pair of receptacles (A and B).Connect each receptacle to an AC outlet using an AC power cord (sold separately). Two power units A and B back up each other. Be sure to make connections to all the two receptacles.

l U (signal ground) terminalFor signal ground.

Note

Note

CAUTION

57Locations and Functions of Parts

Page 58: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

58

IXS-6700 Integrated Routing System

Front panel

a POWER switchesTo turn the power on and off. Power units A1 and B1, and A2 and B2 back up each other. Be sure to set all the four switches to ON.

b POWER indicatorsThese light when power is supplied to the corresponding power units. The indicators are lit in green when operations are normal.If a fan in a power unit stops, the corresponding indicator will light in red.

It is not a problem that the POWER indicators may momentarily flash when the power is turned on, nor that some POWER switches are set to OFF when all the

POWER switches are set to ON while the corresponding POWER indicators may still be lit in red.If you set some POWER switches to OFF when all the POWER switches are set to ON and soon set them to ON again, the POWER indicators for the power units whose POWER switches are set to OFF and ON again may remain lit in red. In such a case, set the POWER switches for the power units whose POWER indicators are lit in red to OFF, wait for about 20 seconds until the indicators go out, then set those POWER switches to ON again.If you wish to set the POWER switch or breaker to OFF after setting all the POWER switches to ON, wait for more than 20 seconds before setting it to OFF.

c Display windowShows the current status of the unit.

INTEGRATED ROUTING SYSTEM IXS-6700MENU ENTERCANCEL

POWER A1

POWER A2

POWER B1

POWER B2

aPOWER switches

bPOWER indicators

cDisplay window

dStatus indicators

eOperation buttons

Note

Locations and Functions of

Parts
Page 59: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

For details on errors, see “Status Indications” on page 63.

d Status indicatorsThese indicate the status of the unit by the color of the indicators and whether they are lit. The indicators are off or lit in green when the power is on and operations are normal. When an error occurs, the indicators light in red.

For details on errors, see “Error Indications and Countermeasures” on page 65.

e Operation buttonsSwitches the display in the display window.

For details on errors, see “Status Indications” on page 63.

Rear panel

a Output panel slotsFor the optional Output Boards.

For details, see “IXS-6600/6700 System Products” on page 46.

b Input panel slotsFor the optional Input Boards.

For details, see “IXS-6600/6700 System Products” on page 46.

c AC IN (AC power input) receptaclesThere are two pairs of receptacles (A1/A2 and B1/B2).Connect each receptacle to an AC outlet using an AC power cord (sold separately). Four power units A1 and B1 back up each other, and A2 and B2 back up each other. Be sure to make connections to all the four receptacles.

d REF IN (reference input) connectors (BNC type)There are four connectors with loop-through function for two signals (A and B).

U

A

NETWORK REMOTE 2

REF IN

REMOTE 3 ALARM

B

A B

A

B

WORDSYNC IN

A

B

REMOTE 1

TC IN

A

B1

C

B2

OUT1

OUT2

IN1

IN2

OUT3

OUT4

IN3

IN4

OUT5

OUT6

IN5

IN6

OUT7

OUT8

IN7

IN8

OUT1 A1

A2

OUT2

IN1

IN2

OUT3

OUT4

IN3

IN4

B2

B1

15

9 6

15

9 6

15

9 6

- AC IN

- AC IN

- AC IN

- AC IN

aOutput panel slots b Input panel slots

dREF IN connectors

eWORD SYNC IN connectors

fREMOTE 1 connectors

cAC IN receptacles

gTC IN connector

hU (signal ground) terminal

iNETWORK connectors

jREMOTE 2 connectors

kREMOTE 3 connector

lALARM connector

cAC IN receptacles

L

59ocations and Functions of Parts
Page 60: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

60

The connectors accept analog reference video signals (black burst compatible with CCIR624 standards or tri-level sync for HDTV).Two connectors of each pair have internal loop-through connections. If loop-through output signals are not used, terminate any connector that is not used with a 75Ω terminator.

If you wish to synchronize signal switching with a reference video signal, set the timing of signal switching (odd or even field) and select reference video signal A or B on the PC (terminal emulator).

For further details, refer to the System Setup Manual (supplied).

e WORD SYNC IN connectors (BNC type)There are four connectors with loop-through function for two signals (A and B).The connectors accept audio word sync signals.Two connectors of each pair have internal loop-through connections. If loop-through output signals are not used, terminate any connector that is not used with a 75Ω terminator.

f REMOTE 1 connectors (BNC type)There are four connectors for three signals, A, B1/B2, and C (two connectors for B).Connect the remote control panels (routing switcher control units) and routing switchers using a single coaxial cable to control the system via S-BUS protocol. When you use this switcher as the primary station 1) (set the S1203-3 P/S switch on the CA-65 board to P), a maximum of 253 remote control panels and routing switchers can be connected via these four connectors.When you use this switcher as a secondary station 1) (set the S1203-3 P/S switch on the CA-65 board to S), connect an S-BUS link to one of the connectors using the supplied T-bridge (type B).

For details, see “System Connection Example” on page 53.

Put the supplied 75Ω terminator(s) on the unused connector(s) regardless whether it is the primary station or secondary station.

1) Remote control operations via S-BUS protocol consist of a data link constructed using a single coaxial cable link. Several pieces of equipment (i.e. routing switchers, remote control panel (routing switcher control unit), etc.) are connected to this data link for data transmission in time-sharing mode. One of the connected switchers is used as the primary station that manages the use of the data link, while the other equipment is used as secondary stations which follow directions from the primary station. The response speed may slow down due to the number of secondary stations.

g TC IN (time code input) connector (BNC type)The connector accepts time code signal.

h U (signal ground) terminalFor signal ground.

i NETWORK connectors (modular jacks)There are two connectors for 100BASE-TX communications for signals A and B.Connect to the Ethernet connector on the PC in which the supplied BZR-20/21 has been installed.

For safety, do not connect the connector for peripheral device wiring that might have excessive voltage to the following ports.• NETWORK A connector• NETWORK B connectorFollow the instructions for the above ports.

j REMOTE 2 connectors (D-sub 9-pin)There are two connectors for signals A and B.Connect an external control unit using a 9-pin remote control cable for use via the RS-422A interface.When the unit is specified for the primary station (set the S1203-3 P/S switch on the CA-65 board to P), S-BUS Convert mode is selected and S-BUS control via the REMOTE 2 connector is enabled.Use the D-sub 9-pin connectors with millimeter screws for connections.

For details, refer to the System Setup Manual (supplied).

k REMOTE 3 connector (D-sub 9-pin)If the switcher is used as the primary station (set the S1203-3 P/S switch on the CA-65 board to P), connect the terminal emulator to make the settings required for system operations.Use the D-sub 9-pin connectors with inch screws for connections.

If you are using the REMOTE 3 connector, set the S1203-3 P/S switch on the CA-65 board to the P position.

For further details, refer to the Installation Manual (supplied).

l ALARM connector (Mini D-sub 15-pin)To output the status of the switchers in the same condition as the status indicators on the front panel.Use the mini D-sub 15-pin connectors with millimeter screws for connections.

For details, see “Specifications” on page 69 and refer to the Installation Manual and System Setup Manual (supplied).

Note

Note

CAUTION

Note

Locations and Functions of Parts

Page 61: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

Option Boards

IKS-V6010M 16 HD/SD Digital Video Input Board

a HD/SD IN 1 to 16 connectors (BNC type)For SDI signal (143 Mbps to 1485 Mbps) input

IKS-V6010SD 16 SD Digital Video Input Board

a SD IN 1 to 16 connectors (BNC type)For SDTV SDI signal (143 Mbps to 360 Mbps) input

IKS-A6011 32 D-sub AES/EBU Input Board

a AES/EBU IN 1-12/13-24 connectors (D-sub 37-pin)For AES/EBU digital audio signal input

b AES/EBU IN 25-32 connector (D-sub 25-pin)For AES/EBU digital audio signal input

IKS-A6012 16 BNC AES/EBU Input Board

a AES/EBU IN 1 to 16 connectors (BNC type)For AES/EBU digital audio signal input

IKS-RS6010 7 RS-422 Input Board

a RS-422 IN 1 to 7 connectors (D-sub 9-pin)For RS-422A signal input

IKS-TC6010 16 Time Code Input Board

a TIME CODE IN 1 to 16 connectors (BNC type)For time code (LTC) signal input

IKS-V6060M 17 HD/SD Digital Video Output Board

1

HD/SD

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 IN

aHD/SD IN 1 to 16 connectors

SD

21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 IN

aSD IN 1 to 16 connectors

119

37 20

119

37 20

113

25 14

AES/EBU 1-12

13-24 25-32 IN

aAES/EBU IN 1-12/13-24 connectors

bAES/EBU IN 25-32 connector

AES/EBU

21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 IN

aAES/EBU IN 1 to 16

115

9 6

215

9 6

315

9 6

415

9 6

515

9 6

615

9 6

7 IN15

9 6

RS-422

aRS-422 IN 1 to 7 connectors

TIME CODE

21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 IN

aTIME CODE IN 1 to 16 connectors

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

OUTHD/SD

aHD/SD OUT 1 to 17 connectors

61Locations and Functions of Parts

Page 62: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

62

a HD/SD OUT 1 to 17 connectors (BNC type)For SDI signal (143 Mbps to 1485 Mbps) output

IKS-V6060SD 17 SD Digital Video Output Board

a SD OUT 1 to 17 connectors (BNC type)For SDTV SDI signal (143 Mbps to 360 Mbps) output

IKS-A6061 34 D-sub AES/EBU Output Board

a AES/EBU OUT 1-12/13-24 connectors (D-sub 37-pin)

For AES/EBU digital audio signal output

b AES/EBU OUT 25-32 connector (D-sub 25-pin)For AES/EBU digital audio signal output

c AES/EBU OUT 33-34 connector (D-sub 9-pin)For AES/EBU digital audio signal output

IKS-A6062 17 BNC AES/EBU Output Board

a AES/EBU OUT 1 to 17 connectors (BNC type)For AES/EBU digital audio signal output

IKS-RS6060 7 RS-422 Output Board

a RS-422 OUT 1to 7 connectors (D-sub 9-pin)For RS-422A signal output

IKS-TC6060 17 Time Code Output Board

a TIME CODE OUT 1 to 17 connectors (BNC type)For time code (LTC) signal output

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

OUTSD

aSD OUT 1 to 17 connectors

119

37 20

119

37 20

113

25 14

15

9 6

AES/EBU 1-12

13-24 25-32 33-34 OUT

aAES/EBU OUT 1-12/13-24 connectors

bAES/EBU OUT 25-32 connector

cAES/EBU OUT 33-34 connector

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

OUTAES/EBU

aAES/EBU OUT 1 to 17 connectors

115

9 6

215

9 6

315

9 6

415

9 6

515

9 6

615

9 6

7 OUT15

9 6

RS-422

aRS-422 OUT 1to 7 connectors

TIME CODE

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

OUT

aTIME CODE OUT 1 to 17 connectors

Locations and Functio

ns of Parts
Page 63: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

Status Indications

The current status of the unit can be displayed in the display window through use of the operation buttons on the front panel.

Displayed Items

The items displayed in the display window are in a tree configuration, as shown below. You can change the displayed item with the operation buttons.

The backlight of the display window will go off about five minutes after the last operation. Pressing any button makes the backlight go back on.

xxxxxxxx ERR

xxxxxxxx ERR

SBUS STATION ID

IP ADDRESS

CPU SW SETTING

CPU RUN

INTEGRATED ROUTING SYSTEM

ERROR STATUS

DISP UNIT STATUS

FAN ELAPSED TIME

PSU ELAPSED TIME

[MENU]

[ENTER]

[CANCEL]

[MENU]

[MENU]

[MENU]

[ENTER]

[CANCEL]

$4

$4

$4

$4

$4

$4

$4

$4

$4

$4

$4

Top display

Error display: Shows errors that occurred in the unit.

Status display: Status of the machine and settings

Errors are displayed in order of importance.For details on errors, see “Error Status” on page 66.

Shows which CPU (main or backup) is active.

Shows the IP address of the network connection for the CPU.

Shows the station ID of the S-BUS.

Shows the settings of the DIP switches on the CA board.

Top menu

Shows the elapsed time of the power unit.

Shows the elapsed time of the fan unit.

63Status Indications

Page 64: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

64

Functions of the Operation Buttons

a MENU buttonPress to return to the top display.

b CANCEL buttonOn a layer below the top menu, this button lets you move to the next layer above.Press to retrieve the stored settings, canceling any changes not yet stored.

c ENTER buttonThis button lets you move to the next layer below.Press to store your settings when the settings have been changed.When this button is pressed together with the MENU button, the setting menu is displayed.

d G g buttonsPress to select an option or move to the adjacent digit of the value.

e F f buttonsPress to change the displayed item on the same layer.

Basic Operations

Basic operations using the operation buttons are as follows:

To display the top display in the display windowPress the MENU button. The top display (INTEGRATED ROUTING SYSTEM) appears in the display window.If the backlight is not lit, press the MENU button again, and the backlight will light.

To move to the next layer belowPress the ENTER button.

To move to the next layer abovePress the CANCEL button.

To change the displayed item on the same layerPress the F or f button.

To return to the top displayPress the MENU button.

Confirming the Status of the Machine

You can confirm the settings of the DIP switches on the internal board, Station ID of the S-BUS station, etc.Proceed as follows:

1 Press the MENU button to display the top display.

2 Press the F or f button to display DISP UNIT STATUS in the display window.

3 Press the ENTER button.

4 Press the F or f button to select an item whose settings are to be confirmed.

CPU RUN: Which CPU (main or backup) is activeCPU SW SETTING: Settings of the DIP switches on

the CA-65 boardIP ADDRESS: IP address of the network connection

of the CPUSBUS STATION ID: Station ID of the S-BUS stationPSU ELAPSED TIME: Elapsed time of each power

unitFAN ELAPSED TIME: Elapsed time of each fan

unit

5 Press the ENTER button.

The item selected in step 4 appears on the second line of the display window.Press the F or f button to change the displayed item.

Adjusting the Contrast of the Display Window

You can adjust the contrast of the display window.Proceed as follows:

1 Press the MENU button to display the top display.

2 Press the G or g button to adjust the contrast.

Pressing the g button increases the contrast, and pressing the G button decreases it.

MENU ENTERCANCEL

aMENU button

bCANCEL button

cENTER button

dG g buttons

eF f buttons

Status Indication

s
Page 65: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

Error Indications and Countermeasures

This switcher performs self-diagnostics when you turn the power on or press the reset button on the CPU board (CA-65) that functions as the main board, as well as at regular intervals during operation. If the self-diagnostics detect an error, the status indicator lights, and information about the error is output to the control terminal (terminal emulator on a PC).

The error code and ERROR No. shown in the status display on the CA-65 board also indicate errors.You can easily determine the origin of an error through such indications.The errors indicated with the status indicators and in the display window, as well as their respective countermeasures, are shown in the tables below.

Status Indicators

Status indicators may be unstable for several seconds when the power is turned on, but this is not a problem.

Status indicators Meaning

StatusCountermeasures

Lit in green Lit in amber Lit in red

1 Redundant status (status of the power units and CA-65 boards)

Normal (The power units and CA-65 boards operate normally.)

• One of the two CA-65 boards is not inserted in a slot.

• The power unit is removed.

• The elapsed time of the power unit exceeds the defined period for periodic replacement.

• Abnormal operation is detected on the CA-65 board.

• Some trouble may occur in the power unit.

Check the meaning of the error and take countermeasures. • Confirm that the switch on

the power unit is set to ON.

• Confirm connection of the power cables.

• Replace a defective power unit.

• Replace a defective CA-65 board.

2 Unit status (status of the fan units, internal temperature, optional boards)

Normal (The fan units, internal temperature, and optional boards are all normal.)

• The elapsed time of the fan unit exceeds the defined period for periodic replacement.

• Some trouble may occur with the fan unit, internal temperature, or optional boards.

Check the meaning of the error and take the countermeasures. • Replace a defective fan

unit or optional board.• Replace a defective

optional board.

3 Remote control/timing status (status of the REMOTE 1 or NETWORK connectors or reference signal input)

Normal (Communication via the REMOTE 1 and NETWORK connectors is normal, and the normal reference signal is input. Or a reference signal is not input, but the setting enables crosspoint switching asynchronously.)

— • Some trouble may occur in the REMOTE 1 or NETWORK communication or reference video signal input.

Check the meaning of the error and take the countermeasures. • Make settings and

connections of the REMOTE 1 and NETWORK connectors.

• Supply the reference video signal or set the timing of switching crosspoints to ASYNC.

For details, refer to the System Setup Manual (supplied).

65Error Indications and Countermeasures

Page 66: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

66

Error Status

You can display the error status in the display window.Proceed as follows:

1 Press the MENU button to display the top display in the display window.

2 Press the f button.

ERROR STATUS appears.

3 Press the ENTER button.

The error status is displayed in order of importance.

The item for which the status is displayed can be changed by pressing the F or f button.

To move to the next layer abovePress the CANCEL button.

To return to the top displayPress the MENU button.

Error status and countermeasures

Display on the 1st line

Display on the 2nd line Word in “x” Meaning Countermeasures

REMOTE1 ERR DISCONNECT CH.xx

A/B1/B2/C S-BUS line is disconnected. • Check the connection with a device not responding, and connect it correctly.

• Use a 75Ω terminator.

REF ERR FAIL CH.x A/B Abnormal• No reference video signal

detected despite the setting to switch the crosspoint synchronously with a reference video signal.

• A reference video signal not supported is detected.

• Supply a reference video signal to the REF IN connector.

• Cancel crosspoint switching synchronized with a reference video signal (set to ASYNC).

For details, refer to the System Setup Manual (supplied).

W/S ERR FAIL CH.x A/B a) Abnormal• An optional audio board is

attached, but an audio reference (word sync) signal or reference video signal is not input.

• A reference signal not supported is input to the WORD SYNC IN connector.

• Supply an audio word sync signal to the WORD SYNC IN connector.

• Supply a reference video signal to the REF IN connector.

MAIN CPU ERR MEM ERR — • Backup data for the main CA-65 board are destroyed.

• Check the main CA-65 board (see “Displayed Items” on page 63), and download the backup data referring the Installation Manual.

BATT.VOLTAGE LOW

— • Voltage of the backup battery for the main CA-65 board is abnormal.

• Check the MAIN CA-65 board (see “Displayed Items” on page 63), and replace the lithium battery of the CA-65 board.

BACKUP CPU ERR

DOWN — • There is a problem with the backup CA-65 board.

• Check which is the main or backup CA-65 board (see “Displayed Items” on page 63), and replace the backup CA-65 board.

PSU ERR FAIL xx A1/A2/B1/B2 b) • There is a problem with the power unit.

• Check that the switch on the power unit is set to ON.

• Check the power cable connection.• Replace a defective power unit.

NON xx A1/A2/B1/B2 b) • No power unit is installed. • Install a power unit.

xx RUN HOUR OVER

A1/A2/B1/B2 b) • The elapsed time of the power unit is past the defined time for periodic replacement.

• Replace the indicated power unit.

Error Indications and Countermeasures

Page 67: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

a) The IXS-6600 has only one WORD SYNC IN connector, but the input signal is divided into two lines of A and B in the unit.

b) A2 and B2 are not displayed on the IXS-6600. Power unit A and B of the IXS-6600 are displayed as A1 and B1 in the display window, respectively.

c) On the IXS-6600, 5, 6, and 7 are not displayed.d) The displayed slot number corresponds to the input or output slot number

on the rear panel of the IXS-6600/6700 as shown below.

FAN ERR x UNIT FAIL L/R • One or more fan units stop or rotation speed exceeds the defined value.

• Replace any defective fan units.

x RUN HOURS OVER

L/R • The elapsed time of the fan unit is past the defined time for periodic replacement.

• Replace the fan unit indicated by OVER.

TEMP ERR HIGH — • Internal temperature exceeds the defined value.

• Check the ambient temperature and the ventilation condition of the unit.

XPT ERR INxxx-OUTxxx Input and output connector number

• There is a problem with the crosspoint.

• Replace a defective optional board.

OPTION BD.ERR

FRONT SLOTxx 1/2/3/4/5/6/7 c) • There is a problem with the optional front board inserted in the unit.

• Replace a defective optional board.

• The slot where the board is inserted is not correct.

• Insert the board in the correct slot.

REAR SLOTxx 1/2/3/4/5/6/7/8/9/10/11/12/13/14/15/16 d)

• There is a problem with the optional rear board inserted in the unit.

• Replace a defective optional board.

• The slot where the board is inserted is not correct.

• Insert the board in the correct slot.

S-BUS CPU ERR

MAINx FAIL A/B/C • There is a problem with the S-BUS CPUx on the main CPU board.

• Replace the defective IF-844 board on the main CA-65 board.

BACKUPx FAIL A/B/C • There is a problem with the S-BUS CPUx on the backup CPU board.

• Replace the defective IF-844 board on the backup CA-65 board.

Display on the 1st line

Display on the 2nd line Word in “x” Meaning Countermeasures

Slot number IXS-6700 IXS-6600

1 OUT1 OUT1

2 OUT2 OUT2

3 IN1 IN1

4 IN2 IN2

5 OUT3 OUT3

6 OUT4 OUT4

7 IN3 IN3

8 IN4 IN4

9 OUT5 --

10 OUT6 --

11 IN5 --

12 IN6 --

13 OUT7 --

14 OUT8 --

15 IN7 --

16 IN8 --

67Error Indications and Countermeasures

Page 68: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

68

Supplied Software

The CD-ROM supplied with the IXS-6600/6700 includes the software described below.

BZR-20 Routing Switcher Data Backup SoftwareThis backs up the setting data for the IXS-6600/6700 for servicing.This can be installed on an IBM PC/AT-compatible machine with Windows XP.

For details, refer to the Installation Manual (supplied).

BZR-21 Routing Switcher Remote Control SoftwareThis enables basic functions such as switching crosspoints, assigning connectors to the switching operation buttons, and checking the operations for configuring the large or small system for easy operations.This can be installed on an IBM PC/AT-compatible machine with Windows XP.

Installing BZR-21

This enables crosspoint switching from a PC. The software also has a function to display the crosspoint statuses and one to find destinations for which a source has been selected.

Operational environmentHardware: IBM PC/AT-compatible machine with

Windows XPCPU: Pentium or equivalent processor with clock speed of

300 MHz or moreMain memory: 128 MB or moreHard disk space: 10 MB or moreDisplay device: Resolution of 800 × 600 pixels or moreInterface: RS-232C or Ethernet

Overview of crosspoint switching with BZR-21You may select the Button per Source system (a method for switching crosspoints by pressing buttons to which appropriate terminals have been assigned in advance) or the X-Y system (for switching crosspoints by specifying terminal names). With the Distribution system, you can specify multiple destinations for a single source.Select your desired system by clicking on the appropriate tab in the main window.

Button per Source system

X-Y system

Distribution system

Terminal assignment to buttonsFor switching with the Button per Source system, you can assign terminals to the operation buttons displayed in the window by drag & drop operation.

Supplied Software

Page 69: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

Installation procedure

1 Load a CD-ROM supplied with the IXS-6600/6700 into the CD-ROM drive.

2 Copy all the files in the \BZR-21 folder from the CD-ROM to a folder on the hard disk.

Use only alphanumerics for the name of a new folder.

3 When copying is completed, double-click on the SETUP.EXE icon.

The installation program will start. Follow the instructions displayed on the screen.

For details on operations with BZR-21, refer to online help of BZR-21.

In “Overview of BZR-21” of BZR-21 online help, it is written “Use the REMOTE 3 (RS-232C) or DATA (Ethernet) connector for connecting with the primary station.” However, on the IXS-6600/6700, use the NETWORK connector (Ethernet) instead of the DATA (Ethernet) connector.

Specifications

The specifications below are for the IXS-6600/6700 and optional boards.

Design and specifications are subject to change without notice.

IXS-6700 Integrated Routing System

GeneralPower requirements 100 to 240 V AC, 50 to 60 HzCurrent drain (maximum value with the full configuration with optional boards)

9.8 A at 100 V AC4.5 A at 240 V AC

Peak inrush current (1) Power ON, current probe method: 145 A (240 V)

(2) Hot switching inrush current, measured in accordance with European standard EN55103-1: 100 A (230 V)

Operating temperature5°C to 40°C (41°F to 104°F)

Operating humidity 10% to 90% (no condensation)Performance-guaranteed temperature

10°C to 35°C (50°F to 95°F)Mass (excluding optional boards)

Approx. 28 kg (61 lb 12 oz)Dimensions (w/h/d) 440 × 354 × 520 mm

(17 3/8 × 14 × 20 1/2 inches)

Mountable unitsSupplied units Power unit (4)

CPU control board (2)Optional units IKS-6030M Matrix Board

IKS-V6050M HD/SD Video Router Processor Board

IKS-V6050SD SD Video Router Processor Board

IKS-A6050 Audio/Data Router Processor Board

IKS-V6010M 16 HD/SD Digital Video Input Board

IKS-V6010SD 16 SD Digital Video Input Board

IKS-A6011 32 D-sub AES/EBU Input Board

IKS-A6012 16 BNC AES/EBU Input Board

IKS-A6015 32 Sampling Rate Converter Board

IKS-RS6010 7 RS-422 Input Board

Note

Note

69Specifications

Page 70: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

70

IKS-TC6010 16 Time Code Input Board

IKS-V6060M 17 HD/SD Digital Video Output Board

IKS-V6060SD 17 SD Digital Video Output Board

IKS-A6061 34 D-sub AES/EBU Output Board

IKS-A6062 17 BNC AES/EBU Output Board

IKS-RS6060 7 RS-422 Output Board

IKS-TC6060 17 Time Code Output Board

Input/output connectorsREMOTE 1 S-BUS remote connector: BNC type

(4) Data transfer rate: 312/1,250 KbpsData transfer format: Bi-Phase

SpaceSignal transfer distance: 500 m at

312 Kbps (when using a BELDEN 8281 75Ω coaxial cable or equivalent)

REMOTE 2 D-sub 9-pin, female (2)Complies with RS-422A signal

standard (can be converted to S-BUS commands)

Protocol: Sony Cart++Data transfer rate: 38.4 Kbps

REMOTE 3 D-sub 9-pin, male (1)Complies with RS-232C signal

standard.For terminal connectionData transfer rate: 38,400 bps8 bits, no parity, no check, 1 stop bit

TC IN BNC type (1)ALARM Mini D-sub 15-pin, female (1)

Parallel, open-collector 6 outputsREF IN BNC type (2) (with loop-through

outputs)Black burstHD tri-level syncWhen used as a reference signal for

a digital audio signal:1125i/50, 59.94, 60750p/59.94, 60625i/50525i/59.94, 60525p/59.94

WORD SYNC IN BNC type (2) (with loop-through outputs)

NETWORK 100BASE-TX: modular jack (2)

Accessories suppliedOperation Guide (1)

CD-ROM (1)Contents Operation Manual

Installation ManualSystem Setup ManualBZR-20 Routing Switcher Data

Backup SoftwareBZR-21 Routing Switcher Remote

Control Software75Ω terminators (3)T-bridge (type B) (1)

Optional accessoriesAC power cord

for USA and Canada only (125 V, 10 A, 2.4 m (8 ft))Part No.: 1-557-377-11

for Europe only (250 V, 10 A, 2.4 m (8 ft))Part No.: 1-782-929-22

IXS-6600 Integrated Routing System

GeneralPower requirements 100 to 240 V AC, 50 to 60 HzCurrent drain (maximum value with the full configuration with optional boards)

6 A at 100 V AC2.5 A at 240 V AC

Peak inrush current (1) Power ON, current probe method: 120 A (240 V)

(2) Hot switching inrush current, measured in accordance with European standard EN55103-1: 75 A (230 V)

Operating temperature5°C to 40°C (41°F to 104°F)

Operating humidity 10% to 90% (no condensation)Performance-guaranteed temperature

10°C to 35°C (50°F to 95°F)Mass (excluding optional boards)

Approx. 17 kg (37 lb 7 oz)Dimensions (w/h/d) 440 × 176 × 520 mm

(17 3/8 × 7 × 20 1/2 inches)

Mountable unitsSupplied units Power unit (2)

CPU control board (2)Optional units IKS-6030M Matrix Board

IKS-V6050M HD/SD Video Router Processor Board

IKS-V6050SD SD Video Router Processor Board

IKS-A6050 Audio/Data Router Processor Board

IKS-V6010M 16 HD/SD Digital Video Input Board

Specifications

Page 71: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

IKS-V6010SD 16 SD Digital Video Input Board

IKS-A6011 32 D-sub AES/EBU Input Board

IKS-A6012 16 BNC AES/EBU Input Board

IKS-A6015 32 Sampling Rate Converter Board

IKS-RS6010 7 RS-422 Input BoardIKS-TC6010 16 Time Code Input

BoardIKS-V6060M 17 HD/SD Digital

Video Output BoardIKS-V6060SD 17 SD Digital Video

Output BoardIKS-A6061 34 D-sub AES/EBU

Output BoardIKS-A6062 17 BNC AES/EBU

Output BoardIKS-RS6060 7 RS-422 Output

BoardIKS-TC6060 17 Time Code Output

Board

Input/output connectorsREMOTE 1 S-BUS remote connector: BNC type

(3) Data transfer rate: 312/1,250 KbpsData transfer format: Bi-Phase

SpaceSignal transfer distance: 500 m at

312 Kbps (when using a BELDEN 8281 75Ω coaxial cable or equivalent)

REMOTE 2/ALARMD-sub 9-pin, female (2)REMOTE 2: Complies with RS-

422A signal standard (can be converted to S-BUS commands)Protocol: Sony Cart++Data transfer rate: 38.4 Kbps

ALARM: Parallel, Open collector 4 outputs

REMOTE 3 D-sub 9-pin, male (1)Complies with RS-232C signal

standard.For terminal connectionData transfer rate: 38,400 bps8 bits, no parity, no check, 1 stop bit

TC IN BNC type (1)REF IN BNC type (2)

Black burst HD tri-level syncWhen used as a reference signal for

a digital audio signal:1125i/50, 59.94, 60750p/59.94, 60

625i/50525i/59.94, 60525p/59.94

WORD SYNC IN BNC type (1)NETWORK 100BASE-TX: modular jack (2)

Accessories suppliedOperation Guide (1)CD-ROM (1)

Contents Operation ManualInstallation ManualSystem Setup ManualBZR-20 Routing Switcher Data

Backup SoftwareBZR-21 Routing Switcher Remote

Control Software75Ω terminators (2)T-bridge (type B) (1)

Optional accessoriesAC power cord

for USA and Canada only (125 V, 10 A, 2.4 m (8 ft))Part No.: 1-557-377-11

for Europe only (250 V, 10 A, 2.4 m (8 ft))Part No.: 1-782-929-22

Optional Boards

IKS-6030M Matrix Board

GeneralPower requirements 12 V DCCurrent drain 4.2 ADimensions (h/d) 317 × 380 mm

(12 1/2 × 15 inches) Mass Approx. 1.3 kg (2 lb 14 oz)

CharacteristicsMatrix size 128 inputs × 68 outputs (256 inputs

× 136 outputs for audio signals)Data transfer rate DC to 1,485 Mbps

Accessory suppliedOperation and Installation Guide (1)

IKS-V6050M HD/SD Video Router Processor Board

GeneralPower requirements 12 V DCCurrent drain 2.2 ADimensions (h/d) 317 × 380 mm

(12 1/2 × 15 inches) Mass Approx. 1.0 kg (2 lb 7 oz)

71Specifications

Page 72: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

72

CharacteristicsSignal processing 34 signalsData transfer rate 143 to 1,485 MbpsReclocked operation signal

SMPTE standard 143, 177, 270, 360, 540, 1,483.5/1,485 Mbps

DVB/ASI standard 270 Mbps signals

Accessory suppliedOperation and Installation Guide (1)

IKS-V6050SD SD Video Router Processor Board

GeneralPower requirements 12 V DCCurrent drain 2.2 ADimensions (h/d) 317 × 380 mm

(12 1/2 × 15 inches) Mass Approx. 1.0 kg (2 lb 7 oz)

CharacteristicsSignal processing 34 signalsData transfer rate 143 to 360 MbpsReclocked operation signal

SMPTE standard 143, 177, 270, 360 Mbps

DVB/ASI standard 270 Mbps signals

Accessory suppliedOperation and Installation Guide (1)

IKS-A6050 Audio/Data Router Processor Board

GeneralPower requirements 12 V DCCurrent drain 1.0 ADimensions (h/d) 317 × 380 mm

(12 1/2 × 15 inches) Mass Approx. 1.1 kg (2 lb 7 oz)

CharacteristicsSignal processing 28 signals (for data signal (RS-

422A))68 signals (for AES/EBU digital

audio signals (balanced))Processed signal Digital audio signal, RS-422A signal

Accessory suppliedOperation and Installation Guide (1)

IKS-V6010M 16 HD/SD Digital Video Input Board

GeneralPower requirements 12 V DCCurrent drain 1.0 ADimensions (h/d) 278 × 95.6 mm

(11 × 3 7/8 inches) Mass Approx. 0.4 kg (14 oz)

CharacteristicsNumber of inputs 16 (BNC type)Input signal SDI signal, 0.8 Vp-pInput data transfer rate

143 to 1,485 MbpsSignal transfer distance

143 to 360 Mbps: 200 m (when using a BELDEN 8281 cable or equivalent)

540 Mbps: 150 m (when using a BELDEN 8281 cable or equivalent)

1,485 Mbps: 100 m (when using a BELDEN 1694 cable or equivalent)

If a BNC cable is connected to an input connector with its end open, the signal detection circuit of this unit may malfunction owing to ambient noise. In such a case, terminate the end of the cable with 75Ω.

Accessory suppliedOperation and Installation Guide (1)

IKS-V6010SD 16 SD Digital Video Input Board

GeneralPower requirements 12 V DCCurrent drain 1.0 ADimensions (h/d) 278 × 95.6 mm

(11 × 3 7/8 inches) Mass Approx. 0.4 kg (14 oz)

CharacteristicsNumber of inputs 16 (BNC type)Input signal SDTV SDI signal, 0.8 Vp-pInput data transfer rate

143 to 360 MbpsSignal transfer distance

200 m (when using a BELDEN 8281 cable or equivalent)

Note

Specifications

Page 73: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

If a BNC cable is connected to an input connector with its end open, the signal detection circuit of this unit may malfunction owing to ambient noise. In such a case, terminate the end of the cable with 75Ω.

Accessory suppliedOperation and Installation Guide (1)

IKS-A6011 32 D-sub AES/EBU Input Board

GeneralPower requirements 12 V DCCurrent drain 0.34 ADimensions (h/d) 278 × 95.6 mm

(11 × 3 7/8 inches) Mass Approx. 0.3 kg (11 oz)

CharacteristicsNumber of inputs 32 (D-sub 37-pin (2), D-sub 25-pin

(1))Input signal 24 bit digital audio signal

conforming to AES3-2003 and AES-2id-1996(r2001)6.3, synchronizing with the reference video signal or word sync signal

Standard input signal level2 to 7 Vp-p (differential,110Ω

terminated)Maximum input signal level

10 Vp-p (differential,110Ω terminated)

Minimum input signal level0.5 V (Fs = 48 kHz)

(differential,110Ω terminated)Input data transfer rate (sampling rate)

6.144 Mbps (Fs=48 kHz)Signal transfer distance

6.144 Mbps: 300 m or more(signal source level:5 Vp-p

differential, when using a cable for digital audio signals)

For an input signal which is not synchronized with the reference video signal or word sync signal or whose transfer rate does not match with the above value, it is recommended to use an IKS-A6015 32 Sampling Rate Converter Board together with this board.

Accessory suppliedOperation and Installation Guide (1)

IKS-A6012 16 BNC AES/EBU Input Board

GeneralPower requirements 12 V DCCurrent drain 0.60 ADimensions (h/d) 278 × 95.6 mm

(11 × 3 7/8 inches) Mass Approx. 0.3 kg (11 oz)

CharacteristicsNumber of inputs 16 (BNC type)Input signal 24 bit digital audio signal

conforming to AES3-2003 and AES-3id-1995 7, synchronizing with the reference video signal or word sync signal

Standard input signal level0.8 to 1.2 Vp-p (75Ω terminated)

Maximum input signal level7 Vp-p (75Ω terminated)

Minimum input signal levelConforming to AES-3id-2001 7.3

Minimum input signalsVmin=320 mV (75Ω terminated)

Input data transfer rate (sampling rate)6.144 Mbps (Fs=48 kHz)

Signal transfer distance6.144 Mbps: 600 m or more(signal source level:1 Vp-p, when

using a BELDEN 8281 cable or equivalent)

For an input signal which is not synchronized with the reference video signal or word sync signal or whose transfer rate does not match with the above value, it is recommended to use an IKS-A6015 32 Sampling Rate Converter Board together with this board.

Accessory suppliedOperation and Installation Guide (1)

IKS-A6015 32 Sampling Rate Converter Board

GeneralPower requirements 3.3 V DC (supplied from the IKS-

A6011)Current drain 0.96 ADimensions (h/d) 116 × 62 mm

(4 5/8 × 2 1/2 inches) Mass Approx. 0.1 kg (4 oz)

CharacteristicsNumber of inputs 32 inputs/outputs

Note

Note

Note

73Specifications

Page 74: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

74

Input/output signal uncompressed format 24 bit digital audio signal received and demodulated on the IKS-A6011

Input data transfer rate (sampling rate)4.928 to 6.144 Mbps (Fs=38.5 to 48

kHz)Output data transfer rate (sampling rate)

6.144 Mbps (Fs=48 kHz)

• This board is designed to be used with the IKS-A6011 32 D-sub AES/EBU Input Board, and cannot be used alone.

• Single channel double sampling frequency mode of the AES-2003 standards is not supported.

Accessory suppliedOperation and Installation Guide (1)

IKS-RS6010 7 RS-422 Input Board

GeneralPower requirements 12 V DCCurrent drain 0.15 ADimensions (h/d) 278 × 95.6 mm

(11 × 3 7/8 inches) Mass Approx. 0.3 kg (11 oz)

CharacteristicsNumber of inputs/outputs

7 (D-sub 9-pin)Input/output signal RS-422A signalInput/output data transfer rate

Conforming to the RS-422A standards

Signal transfer distance1,000 m

Accessory suppliedOperation and Installation Guide (1)

IKS-TC6010 16 Time Code Input Board

GeneralPower requirements 12 V DCCurrent drain 0.19 ADimensions (h/d) 278 × 95.6 mm

(11 × 3 7/8 inches) Mass Approx. 0.4 kg (14 oz)

CharacteristicsNumber of inputs 16 (BNC type)Input impedance 1kΩInput signal Time code (LTC) signal conforming

to the electrical and mechanical

interface characteristics defined by SMPTE 12M-1999 item 8.6

Standard input signal level1.0 to 2.0 Vp-p (1kΩ terminated)

Maximum input signal level4.5 Vp-p (1kΩ terminated)

Minimum input signal level0.5 Vp-p (1kΩ terminated)

Input data transfer rate1/4 to 10x normal play speed

(NTSC/PAL)

Accessory suppliedOperation and Installation Guide (1)

IKS-V6060M 17 HD/SD Digital Video Output Board

GeneralPower requirements 12 V DCCurrent drain 0.35 ADimensions (h/d) 278 × 95.6 mm

(11 × 3 7/8 inches) Mass Approx. 0.4 kg (14 oz)

CharacteristicsNumber of outputs 17 (BNC type)Output amplitude 0.8 Vp-p±10%Data transfer rate 143 to 1,485 MbpsSDI signal output 143, 177, 270, 360 Mbps:

Conforming to SMPTE259M540 Mbps: Conforming to

SMPTE344M1,483.5/1,485 Mbps: Conforming to

SMPTE292MOthers: SMPTE259M/

SMPTE292M selectableSignal transfer distance

143 to 540 Mbps: 200 m (when using a BELDEN 8281 cable or equivalent)

1,485 Mbps: 100 m (when using a BELDEN 1694 cable or equivalent)

Accessory suppliedOperation and Installation Guide (1)

IKS-V6060SD 17 SD Digital Video Output Board

GeneralPower requirements 12 V DCCurrent drain 0.35 ADimensions (h/d) 278 × 95.6 mm

Notes

Specifications

Page 75: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

(11 × 3 7/8 inches) Mass Approx. 0.4 kg (14 oz)

CharacteristicsNumber of outputs 17 (BNC type)Output amplitude 0.8 Vp-p±10%Data transfer rate 143 to 360 MbpsSDI signal output 143, 177, 270, 360 Mbps:

Conforming to SMPTE259MSignal transfer distance

200 m (when using a BELDEN 8281 cable or equivalent)

Accessory suppliedOperation and Installation Guide (1)

IKS-A6061 34 D-sub AES/EBU Output Board

GeneralPower requirements 12 V DCCurrent drain 0.3 ADimensions (h/d) 278 × 95.6 mm

(11 × 3 7/8 inches) Mass Approx. 0.3 kg (11 oz)

CharacteristicsNumber of outputs 34 (D-sub 37-pin (2), D-sub 25-pin

(1), D-sub 9-pin (1))Output signal 24 bit digital audio signal

conforming to AES3-2003 and AES-2id-1996(r2001)6.3, synchronizing with the reference video signal or word sync signal

Output signal level 2.7 Vp-p±20% (differential,110Ω terminated)

Output data transfer rate (sampling rate)6.144 Mbps (Fs=48 kHz)

Accessory suppliedOperation and Installation Guide (1)

IKS-A6062 17 BNC AES/EBU Output Board

GeneralPower requirements 12 V DCCurrent drain 0.14 ADimensions (h/d) 278 × 95.6 mm

(11 × 3 7/8 inches) Mass Approx. 0.3 kg (11 oz)

CharacteristicsNumber of outputs 17 (BNC type)Output signal 24 bit digital audio signal

conforming to AES3-2003 and

AES-3id-1995 4, synchronizing with the reference video signal or word sync signal

Output signal level 1 Vp-p±20% (75Ω terminated)Output data transfer rate (sampling rate)

6.144 Mbps (Fs=48 kHz)

Accessory suppliedOperation and Installation Guide (1)

If you use an audio routing switcher, the amount of delay of AES/EBU audio signals varies.V1.0 and V1.01When SRC is set to OFF: 104 μs (5 words)When SRC is set to ON: 104 μs (5 words) + 2.1 msV1.1 or higherWhen SRC is set to OFF: 146 μs (7 words)When SRC is set to ON: 146 μs (7 words) + 2.1 ms

SRC: Sampling Rate Converter (IKS-6015)

IKS-RS6060 7 RS-422 Output Board

GeneralPower requirements 12 V DCCurrent drain 0.1 ADimensions (h/d) 278 × 95.6 mm

(11 × 3 7/8 inches) Mass Approx. 0.3 kg (11 oz)

CharacteristicsNumber of inputs/outputs

7 (D-sub 9-pin)Input/output signal RS-422A signalInput/output data transfer rate

Conforming to the RS-422A standards

Signal transfer distance1,000 m

Accessory suppliedOperation and Installation Guide (1)

IKS-TC6060 17 Time Code Output Board

GeneralPower requirements 12 V DCCurrent drain 0.16 ADimensions (h/d) 278 × 95.6 mm

(11 × 3 7/8 inches) Mass Approx. 0.4 kg (14 oz)

CharacteristicsNumber of outputs 17 (BNC type)Output impedance 50Ω or less

Reference

75Specifications

Page 76: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

76

Output signal Time code (LTC) signal conforming to the electrical and mechanical interface characteristics defined by SMPTE 12M-1999 item 8.6, excluding item 8.6.3

Output signal level 2 Vp-p±10% (1kΩ terminated)Output data transfer rate

SMPTE mode: 1/4 to 2x normal play speed (NTSC/PAL) (standard setting)

High-speed transfer mode: 1/4 to 10x normal play speed (NTSC/PAL)

In high-speed transfer mode, electrical characteristics specified by SMPTE 12M-1999 item 8.6 cannot be satisfied, because the waveform of the output signal has a steep slope. It is recommended the use in SMPTE mode to obtain the characteristics that satisfy the above standards.

Accessory suppliedOperation and Installation Guide (1)

Note

Specifications

Page 77: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

このマニュアルに記載されている事柄の著作権は当社にあり、説明内容は機器購入者の使用を目的としています。従って、当社の許可なしに無断で複写したり、説明内容(操作、保守等)と異なる目的で本マニュアルを使用することを禁止します。

The material contained in this manual consists of information that is the property of Sony Corporation and is intended sole-ly for use by the purchasers of the equipment described in this manual.Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose oth-er than the operation or maintenance of the equipment de-scribed in this manual without the express written permission of Sony Corporation.

商標について•イーサネットはXEROX社の登録商標です。•Windowsは米国Microsoft Corporationの米国およびその他の国における登録商標または商標です。

About trademarks• Ethernet is a registered trademark of XEROX Corporation.• Windows is either a registered trademark or a trademark of

Microsoft Corporation in the United States and/or other countries.

Page 78: INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 ...discoveryresources.com/Documents/IXS6600_IXS6700_Op...INTEGRATED ROUTING SYSTEM IXS-6600 IXS-6700 OPERATION MANUAL [Japanese/English]

Sony CorporationIXS-6600/6700(SY)3-990-631-05(1) © 2005