June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch) The ARIES Team Presented by A. René Raffray and Xueren Wang ARIES Project Meeting University of Wisconsin, Madison June 19-21, 2000

June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

  • View
    220

  • Download
    5

Embed Size (px)

Citation preview

Page 1: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

ARIES-AT Blanket and Divertor Design(The Final Stretch)

The ARIES Team

Presented by A. René Raffray and Xueren Wang

ARIES Project Meeting

University of Wisconsin, Madison

June 19-21, 2000

Page 2: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Presentation Outline

• Blanket– Geometry and coolant routing

– Update analysis and parameters based on 3/10/00 strawman

– New analysis• 2-D moving coordinate thermal analysis

• Pressure stress in inner SiC/SiC separation wall

• Manifolding– Thermo-fluid analysis

• Divertor– Configuration with LiPb as coolant

– Thermal and stress analysis

– Fabrication

• Summary

Page 3: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

ARIES-AT Machine and Power Parameters from 3/10/00 Strawman

Power and Neutronics Parameters• Fusion Power 1719 MW• Neutron Power 1375 MW• Alpha Power 344 MW• Current Drive Power 25 MW• Transport Power to Divertor 256 MW• Fraction of Divertor Power Radiated Back

to FW TBD• Overall Energy Multiplication 1.1• Total Thermal Power 1897 MW• Average FW Surface Heat Flux 0.26

MW/m2

• Max. FW Surface Heat Flux 0.34 MW/m2

• Max. Divertor Surf. Heat Flux 5 MW/m2

• Average Wall Load 3.2 MW/m2

• Maximum O/B Wall Load 4.8 MW/m2

• Maximum I/B Wall Load 3.1 MW/m2

Machine Geometry

• Major Radius 5.2 m

• Minor Radius 1.3 m

• FW Location at O/B Midplane 6.5 m

• FW Location at Lower O/B 4.9

• I/B FW Location 3.9 m

Toroidal Magnetic Field

• On-axis Magnetic Field 5.9 T

• Magnetic Field at I/B FW 7.9 T

• Magnetic Field at O/B FW 4.7 T

Page 4: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

SiC/SiC Properties Used for Design Analysis

(Consistent with SiC/SiC Town Meeting Suggestion)

• Density ~3200 kg/m3

• Density Factor 0.95

• Young's Modulus ~200-300 GPa

• Poisson's ratio 0.16-0.18

• Thermal Expansion Coefficient 4 ppm/°C

• Thermal Conductivity in Plane ~20 W/m-K

• Therm. Conductivity through Thickness ~20 W/m-K

• Maximum Allowable Combined Stress ~190 MPa

• Maximum Allowable Operating Temperature ~1000 °C

• Max. Allowable SiC/LiPb Interface Temperature ~1000°C

• Maximum Allowable SiC Burnup ~ 3%

Page 5: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Cross-Section and Plan View of ARIES-AT Showing Power Core Components

Page 6: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Cross-Section and Plan View of ARIES-AT Showing Maintenance Approach

• All Lifetime Components Except for: Divertor, IB Blanket, and OB Blanket I

Page 7: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Coolant Routing Through 5 Circuits Serviced by Annular Ring Header (I)

Circuit 1: Lower Divertor + IB BlanketLiPb CoolantInlet Temperature 653 °COutlet Temperature 1100 °C Blanket Inlet Pressure 1 MPa Divertor Inlet Pressure 1.7 MPa Mass Flow Rate 22,700 kg/s

Circuit 1 - Lower Divertor + IB Blkt RegionThermal Power and Mass Flow Rate:

501 MW and 6100 kg/sCircuit 2 - Upper Divertor + 1/2 OB Blanket I

598 MW and 7270 kg/sCircuit 3 - 1/2 OB Blanket I

450 MW and 5470 kg/s Circuit 4 - IB Hot Shield + 1/2 OB Blanket II

182 MW and 4270 kg/s Circuit 5 - OB Hot Shield + 1/2 OB Blanket II

140 MW and 1700 kg/s

Page 8: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Coolant Routing Through 5 Circuits Serviced by Annular Ring Header (II)

Circuit 3: 1/2 OB Blanket IICircuit 2: Upper Divertor + 1/2 OB Blanket I

Page 9: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Coolant Routing Through 5 Circuits Serviced by Annular Ring Header (III)

Circuit 5: OB Hot Shield + 1/2 OB Blanket IICircuit 4: IB Hot Shield + 1/2 OB Blanket II

Page 10: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

ARIES-AT Outboard Blanket Segment Configuration and Coolant Manifold

Page 11: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Cross-Section of ARIES-AT Outboard Blanket

Page 12: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

LiPb Temperature Distribution in FW Channel and Inner Channel under MHD-Laminarization

Effect

q''plasma

Tin

Tw

Tw

TLiPb,minTin

Tin

FW Exit(Upper Outboard)

FW Midplane

FW Inlet(Lower Outboard)

TLiPb,avg

TLiPb,avgTLiPb,min

LiPb

q'''LiPb

Tin Tout

q''back

vback

vFW

Poloidal

Radial

InnerChannel

FWChannel

SiC/SiC FWSiC/SiC Inner Wall

Page 13: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Poloidal Distribution of Surface Heat Flux and Neutron Wall Load from 3/10/00 Strawman

0.00

0.10

0.20

0.30

0.40

0.50

0.60

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15Poloidal Distance from Lower Outboard (m)

Assuming 10% divertortransport power re-radiation

Assuming no radiationfrom divertor

OUTBOARD INBOARD

DIV.

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

5.00

5.50

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15Poloidal Distance from Lower Outboard (m)

OUTBOARD INBOARD

DIV.

Average Neutron Wall Load = 3.19 MW/m2

Page 14: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Temperature Distribution in ARIES-AT Blanket Based on 2-D Moving Coordinate

Analysis

• LiPb Inlet Temperature = 764 °C• From Plasma Side: - CVD SiC Thickness = 1 mm - SiC/SiC Thickness = 4 mm (SiC k = 20 W/m-K)

- LiPb Channel Thickness = 4 mm - SiC/SiC Separ. Wall Thickness = 5 mm ( SiC k = 6 W/m-K)

• LiPb Velocity in FW Channel= 4.2 m/s• LiPb Velocity in Inner Channel = 0.1 m/s• Poloidal neutron wall load and plasma heat flux profiles used as input (assuming no radiation from divertor) 700

800

900

1000

1100

1200800

900

1000

1100

1200

1

2

3

4

5

6

00.020.040.060.080.1

00.020.040.060.080.1 700

800

900

1000

1100

1200

Radial distance (m)

Poloidaldistance(m)

LiPb

SiC/SiC

Page 15: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

2-D Moving Coordinate Analysis of FW and Inner Channel

• Poloidal neutron wall load and plasma heat flux profiles used as input (assuming no radiation from divertor) • FW Maximum CVD and SiC/SiC Temperature = 1009°C° and 996°C°• Maximum SiC/LiPb Interface Temperature at Inner Wall = 994 °C

(occurs at higher ypoloidal as kSiC increases)

700

750

800

850

900

950

1000

1050

1100

1150

Temp.(°C)

0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1

Radial Thickness from FW Surface (m)

ARIES-AT Outboard Blanket Module• Series Flow: FW Channel and Inner Channel • FW SiC/SiC Thickness = 5 mm• FW Channel Thickness = 4 mm • SiC/SiC Inner Wall Thickness = 5 mm

• Inner Channel Effective Thickness = 9 cm

• SiC/SiC First Wall k = 20 W/m-K

• SiC/SiC Inner Wall k = 6 W/m-K

• LiPb Inlet Temperature = 764 °C

Midplane

Upper PoloidalLocation

Lower PoloidalLocation

FW CVDSiC Armor

FW LibPInner SiC

Inner LiPb Channel

FW SiC/SiC

800

850

900

950

1000

1050

1100

Temp.(°C)

0 2 4 6 8 10 12 14 16 18 20 22

Inner Wall SiC/SiC Thermal Conductivity (W/m-K)

Max. SiC/LiPb Interface Temp.

Max. CVD SiC Temp.

Max. SiC/SiC Temp.

ARIES-AT Outboard Blanket Module• Series Flow: FW Channel and Inner Channel • FW SiC/SiC Thickness = 5 mm• FW Channel Thickness = 4 mm • SiC/SiC Inner Wall Thickness = 5 mm

• Inner Channel Effective Thickness = 9 cm

• SiC/SiC First Wall k = 20 W/m-K

• LiPb Inlet Temperature = 764°C

Upper Poloidal Location

Lower Poloidal Location

DesignPoint

Page 16: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Pressure Stress Analysis of Inner Shell of Blanket Module

• Differential Pressure Stress on Blanket Module Inner Shell Varies Poloidally from ~ 0.25 MPa at the Bottom to ~ 0 MPa at the Top

• Maximum Pressure Stress for 0.25 MPa Case

– 218 MPa for 5-mm thickness

– 116 MPa for 8-mm thickness

• Use 7 mm as reference case to comfortably maintain combined stress limit < 190 MPa

• Thickness Varies from7 mm at Bottom to ~ 3 mm at Top

Page 17: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Manifolding Analysis

• Annular manifold configuration with low temperature inlet LiPb in outer channel and high temperature outlet LiPb in inner channel

• Can the manifold be designed to maintain LiPb/SiC Tinterface< LiPb Toutlet while maintaining reasonable P?

• Use manifold between ring header and outboard blanket I as example

LiPbInlet

LiPbOutlet

riro

q''

Page 18: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

LiPb/SiC Tinterface, LiPb TBulk due to Heat Transfer in SiC/SiC Annular Piping, and P as a Function of Inner

Channel Radius• Reduction in Tinterface at the expense of additional heat transfer from outlet LiPb to inlet LiPb and increase in LiPb Tinlet • Very difficult to achieve maximum LiPb/SiC Tinterface < LiPb Toutlet

• However, manifold flow in region with very low or no radiation• Set manifold annular dimensions to miminimize Tbulk while maintaining a reasonable P

Page 19: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Divertor Design

• Preferred Option: LiPb Cooled Configuration– Single power core cooling system

– Low pressure and pumping power

– Analysis indicates that proposed configuration can accommodate a maximum heat flux of ~5-6 MW/m2

• Alternate Options:– He-Cooled Porous Exchanger

• Higher pressure, pressure drop and pumping power

• Challenging heat transfer performance if He from power cycle at ~600°C inlet temperature

– Liquid Wall (Sn-Li)

Page 20: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

ARIES-AT Divertor Configuration and LiPb Cooling Scheme

LiPb Poloidal Flow in ARIES-ATDivertor Header

PoloidalDirection

ToroidalDirection

Example schematic illustrationof 2-toroidal-pass schemefor divertor PFC cooling

Plasma q''

A ACross-Section A-A

Accommodating MHD Effects:• Minimize Interaction Parameter (<1) (Strong Inertial Effects)• Flow in High Heat Flux Region Parallel to Magnetic Field (Toroidal)• Minimize Flow Length and Residence Time• Heat Transfer Analysis Based on MHD-Laminarized Flow

Page 21: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Temperature Distribution in Outer Divertor PFC Channel Assuming MHD-Laminarized LiPb Flow

δBTPFC

LiPb LiPb

• 2-D Moving Coordinate Analysis• Inlet temperature = 653°C• W thickness = 3 mm• SiC/SiC Thickness = 0.5 mm• LiPb Channel Thickness = 2 mm• SiC/SiC Inner Wall Thick. = 0.5 mm• LiPb Velocity = 0.35 m/s• Surface Heat Flux = 5 MW/m2

700

800

900

1000

1100

1200

600

700

800

900

1000

1100

0

0.005

0.01

0.015

0.02

00.001

0.0020.003

0.0040.005

0.0010.002

0.0030.004

0.0050.006

600

700

800

900

1000

1100

1200

Radial distance (m)

Toroidal distance (m)Tungsten

SiC/SiC

LiPb

Page 22: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Thermal Analysis of Divertor Channel

• Maximum SiC/SiC Temperature ~ 950°C• Maximum SiC/SiC Thermal Stress ~ 160 MPa

Page 23: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Pressure Stress and Pressure Drop in Divertor Channel

0.00

0.50

1.00

1.50

2.00

0 0.01 0.02 0.03 0.04 0.05

Toroidal Dimension of Divertor Channel (m)

Inner Channel

Orifice

PFC Channel

Total

δBTPFC

LiPb LiPb

• 2-cm toroidal dimension and 2.5 mm min. W thickness selected (+ 1mm sacrificial layer)

- SiC/SiC pressure stress ~ 35 MPa for a combined stress of ~195 MPa - P is minimized to ~0.55 MPa for lower divertor and ~0.7 MPa for upper divertor

• Maximum SiC/SiC Temperature ~ 950°C

Page 24: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Outer Divertor Plate with Brazed Coolant Manifold

• Minimize brazing– SiC/SiC plate manufactured

in two toroidal halves with constant dimension channels

– Flow insert slided in

– Two halves brazed together

– End cap + manifold brazed on each end

– W layer bonded to SiC/SiC (possibly by plasma spray, to be checked by M. Billone)

Page 25: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Typical Blanket and Divertor Parameters for Design Point

Blanket Outboard Region 1• No. of Segments 32

• No. of Modules per Segment 6

• Module Poloidal Dimension 6.8 m

• Avg. Module Toroidal Dimen. 0.19 m

• FW SiC/SiC Thickness 4 mm

• FW CVD SiC Thickness 1 mm

• FW Annular Channel Thickness 4 mm

• Avg. LiPb Velocity in FW 4.2 m/s

• FW Channel Re 3.9 x 105

• FW Channel Transverse Ha 4340

• MHD Turbulent Transition Re 2.2 x 106

• FW MHD Pressure Drop 0.19 MPa

• Maximum SiC/SiC Temp. 996°C

• Maximum CVD SiC Temp. (°C) 1009 °C

• Max. LiPb/SiC Interface Temp. 994°C

• Avg. LiPb Vel. in Inner Channel 0.11 m/s

Divertor• Poloidal Dimension (Outer/Inner) 1.5/1.0 m• Divertor Channel Toroidal Pitch 2.1 cm• Divertor Channel Radial Dimension 3.2 cm• No. of Divertor Channels (Outer/Inner) 1316/1167• SiC/Si Plasma-Side Thickness 0.5 mm• W Thickness 3.5 mm• PFC Channel Thickness 2 mm• Number of Toroidal Passes 2• Outer Div. PFC Channel V (Lower/Upper) 0.35/0.42 m/s• LiPb Inlet Temperature (Outer/Inner) 653/719 °C• Pressure Drop (Lower/Upper) 0.55/0.7 MPa• Max. SiC/SiC Temp. (Lower/Upper) 970/950°C• Maximum W Temp. (Lower/Upper) 1145/1125°C• W Pressure + Thermal Stress ~35+50 MPa• SiC/SiC Pressure + Thermal Stress ~35+160 MPa• Toroidal Dimension of Inlet and Outlet Slot 1 mm• Vel. in Inlet & Outlet Slot to PFC Channel 0.9-1.8 m/s• Interaction Parameter in Inlet/Outlet Slot 0.46-0.73

Page 26: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Extra Margin on Accommodating Temperature Limit by Reducing Coolant Temperature with Relatively Small Impact on Brayton Cycle

• Brayton Cycle Parameters: - Min. He Temp. in cycle (heat sink) = 35 °C - 3-stage compression with 2 inter-coolers - Turbine efficiency = 0.93 - Compressor eficiency = 0.88 - Recuperator effectiveness = 0.96 - Cycle He fractional P = 0.03 - Total Compression ratio = 3

• Heat Exchanger: - Effectiveness = 0.9 - (mCp)He/(mCp)LiPb = 1

500

600

700

800

900

1000

1100

1200

0.54 0.55 0.56 0.57 0.58 0.59 0.6

Cycle Efficiency

Blanket LiPbOutlet Temp.

Cycle He Temp. at HX Inlet

Cycle He Max. Temp.(at HX Outlet )

Cycle He Temp. at HX Outlet

Temp.(°C)

Page 27: June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)

June19-21, 2000 Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR

Future Work Includes:

• Complete 3-D structural analysis of divertor– Surface heat flux profile required (GA)

• Evolve in more detail blanket and divertor fabrication flow diagrams

• Documentation