KIP 2000 Series SCSI Scanner User Manual Ver E Kip

  • View
    442

  • Download
    6

Embed Size (px)

Transcript

KIPSCANNERS SCANNERS SCANNERS SCANNERS

2000 Series SCSI Scanners

KIP 2050 / KIP 2080 KIP 2120

User's ManualVer E.2

We highly appreciate your purchasing our Image Scanner K-75 series (KIP2050, 2080, 2120 and 2160). This USER'S MANUAL contains functional and operational explanation of the Image Scanner K-75 series. Read this USER'S MANUAL carefully before use in order to understand the K-75 series fully and to use more efficiently. Keep this USER'S MANUAL for future reference. 1. When K-75 series is installed in U.S.A. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 2. When K-75 series is installed in Europe This equipment complies with the requirements in Pub.22 of CISPR Rules for a Class B computing device. Operation of this equipment in a residential area may cause unacceptable interference to radio and TV reception requiring the operator to take whatever steps are necessary to correct the interference. Do not install Machine around electronics equipment or precision instruments. It may be influenced by electrical reason or vibration while printing. If Machine is installed near electronics equipment, such as TV or radio, interference to equipment, such as noise or flickering may be occurred. Use separate power line and install Machine as far as such equipment.

A75UMCON (Ver. E.2)

1

WARNINGS FOR THE SAFETY (OBSERVE THESE WARNING)Following warnings are very important to use this equipment safely and to prevent the operator from danger and his/her property from being damaged. Hazardous or damage degree is classified and shown as follows when this machine is erroneously used ignoring this USER'S MANUAL.

WARNINGThis caution mark denotes that the failure to follow given instructions in handling the machine could result in a death or serious injury.

CAUTIONThis caution mark denotes that the failure to follow given instructions in handling the machine could result in an injury or physical damage only.

This symbol signifies what must not be done.

This symbol signifies General Mandatory Action.

A75UMCON (Ver. E.2)

2

WARNINGSConnect the scanner and Ground with each other surely with the grounding wire. Otherwise, it is dangerous for you if you receive an electric shock or at the time of lightning. If the outlet does not have a Grounding Terminal or if it is impossible to connect, call the vendor or service professional for the installation. 1. Power source should be rated from 100V to 240V plus or minus 10%, more than 6A and 50/60Hz. 2. It is preferable that the used power circuit is provided with a dedicated breaker. 3. Install the machine as close as possible to the outlet. 4. When you wish to move the machine to another place, make sure to ask your service engineer. 1. Do not use a multi-wiring connector that might raise the temperature of the outlet abnormally and cause a fire. 2. Do not put anything heavy on the power cord. It may cause a fire or receiving an electric shock. 3. Do not step on the power cord, and do not damage or process it. It may also cause a fire or receiving an electric shock. 4. Do not tie the power cord or make a knot on it. It may also cause a fire or receiving an electric shock. 5. Do not put a flower vase, a flowerpot or a water-filled glass on the top of the machine. If the water spilt out, it may also cause a fire or receiving an electric shock. 1. If the machine generates abnormal smell or noise, turn it off and then disconnect the power plug from the outlet necessarily. 2. Do not handle the power plug with the wet hand positively. It may cause to receive an electric shock. 3. Insert the power plug into the outlet completely. If the power plug is not inserted completely, it may cause a fire. 4. Use only the attached power cord. Make sure to catch the Plug when you unplug the machine. Otherwise, you may break the cord and may result in a fire or receiving an electric shock.

Do not disassemble or tamper the machine. Otherwise, it may cause a fire or receiving an electric shock.

A75UMCON (Ver. E.2)

3

CAUTIONSDo not install the machine at the following places. 1. Humidified or dusty place. 2. Unstable floor. When the machine comes down, it may cause the injury. Be careful not to catch your hand between Upper Unit and Main Unit when you close the Upper Unit.

1. Unplug the machine before you move it to another place. Otherwise, the power cord may be damaged and may result in a fire or receiving an electric shock. 2. If nobody operates the scanner in the night time, make sure to turn it off for the safety. 3. If nobody operates the machine for a long time during consecutive holidays, make sure to turn it off for the safety. 4. Nothing should be put near the power plug so as to disconnect it quickly anytime.

A75UMCON (Ver. E.2)

4

TABLE OF CONTENTSChapter 1 Before Use1.1 Required Conditions for the Installation Place Page 1- 1 1- 2 1- 2 1- 2 1- 2 1- 3 1- 4 1- 5 1- 5 1- 5 1- 6 1- 7 1- 7 1- 9 1-12 1-13 1.2 Originals Prohibited to Copy 1.2.1 Prohibited items by the law 1.2.2 Special items to be cared 1.2.3 Items protected by the copyright 1.3 1.4 Features Specifications

1.5 Name of Each Part and Its Function 1.5.1 Front view 1.5.2 Rear view 1.5.3 Operation Panel 1.6 1.7 1.8 1.9 Power Indicator and Ready Indicator Warning Indications How to Operate the LCD Difference of Action at the Time of Memory Full

1.10 Scan Mode

Chapter 2 Simple Copying2.1 2.2 2.3 2.4 2.5 2.6 2.7 Turning on the Scanner Applicable Original Explanation for Copy Job Setting the Original to the Scanner Copying by the Roll Media Feeding Copying by the Sheet Media Feeding Pre-scan Page 2- 1 2- 3 2- 4 2- 6 2- 8 2-11 2-15 2-17 2-17 2-18 2-19

2.8 Treatment against Roll Empty during Copying 2.8.1 Another Roll Deck has same roll media 2.8.2 No Roll Deck has same roll media 2.9 Turning off the Scanner

A75UMCON (Ver. E.2)

5

Chapter 3 Operation3.1 Introduction Page 3- 1 3- 2 3- 5 3- 6 3- 7 3- 7 3-10 3-11 3-11 3-15 3-17 3-17 3-19 3-22 3-27 3-28 3-28 3-31 3-33 3-35 3-37 3-38 3-40 3-44 3-45 3-47 3-51 3-54 3-56 3-58 3-60 3-62 3-64 3-66 3-67 3-68 3-71 3-73 3-79 3-80 3-82 3-84 3-85 3-90 3-91 3-92 3-95 3-96 3.2 Basic Screen 3.2.1 Copy Count setting (Number of copies) 3.3 Copying Media Settings 3.3.1 Roll media feeding A. Automatic roll selection (Auto Paper Mode) B. Manual roll selection 3.3.2 Sheet media feeding A. Automatic sheet size selection (Auto Sheet Size Mode) B. Manual sheet size selection 3.3.3 Cut Modes A. Synchro Cut B. Standard Cut 3.3.4 Divide Mode 3.4 Zoom Settings 3.4.1 Auto Zoom Mode A. In case of the roll media feeding B. In case of the sheet media feeding 3.4.2 Standard Zoom Ratio 3.4.3 % Mode (Direct selection of percentage) 3.4.5 Media Size Mode (Ratio between original size and media size) 3.4.6 Zoom Program Mode 3.4.7 XY Zoom Mode 3.5 Image Quality Settings 3.5.1 Selecting originals image type 3.5.2 Background Mode 3.5.3 Despeckle Mode 3.5.4 Threshold A. Function of Threshold Level in the Line Mode B. Function of Threshold Level in the Line/Photo Mode C. Function of Threshold Level in the Photo Mode Sharpness Density

3.5.5 3.5.6

3.6 Function Settings 3.6.1 Shift and Centering A. Shift B. Centering 3.6.2 Leading Edge and Trailing Edge 3.6.3 Folder Setting 3.6.4 Mirror Image Mode 3.6.5 Negative Image Mode 3.7 Date Stamp Settings 3.7.1 How to print the Date Stamp 3.7.2 Main position of Date Stamp 3.7.3 Rotation of Date Stamp 3.7.4 Horizontal shift and vertical shift of Date Stamp 3.7.5 Order of date and time 3.7.6 Type of Date Stamp

A75UMCON (Ver. E.2)

6

3.8 Set Copy Mode 3.8.1 Explanation for Set Copt Job 3.8.2 Set Copy in the Layout Mode 3.8.3 Set Copy in the Sort Mode 3.8.4 Concurrent Print Mode (Check Set) 3.9 Mode Memory 3.9.1 Calling the Mode Memory 3.10 Menu Settings 3.10.1 Original 3.10.2 Edit Function A. Re-edit B. Delete C. Insert D. Replace E. All Cancel 3.10.3 Setting A. How to register the setting B. Register Zoom Ratio C. Original Format D. Auto Start E. Standard Mode F. Mode Memory (Creation and deletion of Mode Memory) G. Memory H. Date / Time I. SCSI 3.10.4 Command A. Initial Cut B. Wire Cleaning C. Information 3.11 Reference Screen 3.12 Power Save Function 3.13 Scanner Power Save 3.14 Auto Reset Function 3.15 Interrupt Mode 3.16 Reset 3.17 Re-copy 3.18 Sample Copy 3.19 Rotate Mode

3-98 3-100 3-102 3-112 3-120 3-121 3-122 3-124 3-125 3-129 3-131 3-133 3-135 3-138 3-141 3-142 3-143 3-145 3-148 3-149 3-151 3-157 3-161 3-163 3-165 3-167 3-168 3-170 3-171 3-173 3-176 3-178 3-179 3-180 3-181 3-182 3-184 3-185

Chapter 4 Error Indications and Treatments4.1 Error Message and Treatments Page 4-1

A75UMCON (Ver. E.2)

7

Chapter 5 Maintenance and Adjustments5.1 Usual Maintenance Page 5- 1 5- 4 5- 4 5- 6 5- 9 5.2 LCD Adjustments 5.2.1 LCD contrast adjustment 5.2.2 Touch panel positioning 5.3 Pin Layout and Rating of Interface Connector

A75UMCON (Ver. E.2)

8

Chapter 1 Before Use

1.1

Required Conditions for the Installation Place

Page 1- 1 1- 2 1- 2 1- 2 1- 2 1- 3 1- 4 1- 5 1- 5 1- 5 1- 6 1- 7 1- 7 1- 9 1-12 1-13

1.2 Originals Prohibited to Copy 1.2.1 Prohibited items by the law 1.2.2 Special items to be cared 1.2.3 Items protected by the copyright 1.3 1.4 Features Specifications

1.5 Name of Each Part and Its Function 1.5.1 Front view 1.5.2 Rear view 1.5.3 Operation Panel 1.6 1.7 1.8 1.9 Power Indicator and Ready Indicator Warning Indications How to Operate the LCD Difference of Action at the Time of Memory Full

1.10 Scan M