MICROFLOW LOG
Cable blowing machine for FTTH FIBERS (EPFU) AND MICRO CABLES
SPECIFICATIONSItem no.: ................ .................................................. 101-171001001Fiber/cable diameter: ...................................................... 0.8 - 6.5 mmMicroduct diameter: ........................................................... 4 - 16 mmBlowing distance1: .......................................................... Up to 2500 mBlowing speed1: .......................................................... Up to 90 m/min.Recommended pressure and airflow2: ........ 8-16 bar (200-500 l/pr. min.)Weight (including control unit): .................................................. 13.2 kgLength (blowing head/control unit): ............................. 250 mm/240 mmWidth (blowing head/control unit): .............................. 150 mm/250 mmHeight (blowing head/control unit): ................................ 220 mm/80 mm1) Depending on type of microduct and cable.2) Cooled and dried air.
Gabocom HF Fremco Microflow
SNR 7x1,5 A-D 2Y 1x12
SNR 1,5 12 Ohne
Grün 2,6 Kaeser
gerieft
°C 23°C nein
SpeedNet-System Einblas - Protokoll
Bauvorhaben Nr. Fresco Deutsche telecom test 2018-05-30 Datum, Startzeit: 2018-05-30 10:58
Streckenabschnitt / NVt Ellehammervej 14
Firma Femco Einbläser: Jacob kühn
Bemerkungen Aliens ok
Rohrparameter Kabelparameter Einblasgerät/ Kompressor
Hersteller: Hersteller: Einblasgerät:
Rohrverband: Bezeichnung: + Lubricator [ nein ]
Rohr: Faserzahl: Gleitmittel:
Farbe-Kennung: Kabel-Durchmesser: Kompressor:
Rohrinnenwand: Meterzahlen: Start: 4510 | Ende: 4804
+ Ölabscheider [ nein ] + Nachkühler [ nein ]
SNR-Temperatur: Kabel-Temperatur: Kabel-Einblaskappe:
Zusammenfassung
Strecke: 294 Einblaszeit: 0:08:46 Wetter: 34.5°C, 29.8%RH Ort(GPS): 57.448396667,10.492838333
Each job will end with a full report that ensures that the quality is 100% documented. This will minimize the risk of costly errors.
The MicroFlow LOG is of course equipped with the unique well-known protection technology that stops the machine if the fiber cable meets resistance. Any stop is registered by a sensor and the motor stops. The machine will also stop automatically if the motor exceeds the preset maximum torque level. In both cases the machine stops immediately so the fiber cable does not get damaged.
Fremco A/S · Tel. +45 72 30 12 13 · www.fremco.dk
110/230 V
The Microflow LOG is a fiber blowing machine with a data driven decision tool which minimizes the risk of costly errors due to wrong blowing techiques. Online diagnostics can show you how the machine operates and how to improve the utilization.
HIGHLIGHTS• Compatible with OptiCloud• Deutsche Telekom Template• The Log template can be individually adapted• Easy connection to controller • Verification of blowing quality (e.g. pressure, length, recommended speed,
stress on cable etc)• Remote support
BENEFITS• Confirmation of job, location and time via invoice• Quality based documentation such as stress on the
cable, comparison of different types of cable and if predetermined blowing limitation are exceeded.
• Best practice for blowing teams• Utilization • Maintenance & Service Recommendation of the fiber blowing machine
Approved by:
for DTAG ZTV 40-II
Valid from September 23, 2019.
Fremco A/S · Tel. +45 72 30 12 13 · www.fremco.dk
MicroFlow V5 adaptor plates
All MicroFlow machines must be fitted with adaptor plate set. All adaptor plates are replaceable, making the machine more flexible when blowing different sizes of cable. The set consists of an upper and a lower plate, which together form a compact airtight unit around duct and fiber.
Adaptor plate set includes:• Sensor arm kit or super straight kit - size optional.• Drive wheels with O-rings.• Inlet guides.
MICROFLOW TOUCH & LOGADAPTOR PLATES
PLEASESTATE
FIBER/CABLE SIZE
AND DUCT SIZEWHEN
ORDRERING!
The adaptor plates are available in different sizes for 5-16 mm duct OD and 0.8-6.5 mm fiber/cable.
Inlet guides:1.5-6.8 mm.
O-rings fordrive wheels:2.0-6.5 mm.
MicroFlow V5gaskets areavailable in different sizes for 5-16 mm duct OD and 0.8-6.5 mm fiber/cable.