2
MICROFLOW LOG Cable blowing machine for FTTH FIBERS (EPFU) AND MICRO CABLES SPECIFICATIONS Item no.: ................ .................................................. 101-171001001 Fiber/cable diameter: ...................................................... 0.8 - 6.5 mm Microduct diameter: ........................................................... 4 - 16 mm Blowing distance 1 :.......................................................... Up to 2500 m Blowing speed 1 : .......................................................... Up to 90 m/min. Recommended pressure and airflow 2 : ........ 8-16 bar (200-500 l/pr. min.) Weight (including control unit): .................................................. 13.2 kg Length (blowing head/control unit): ............................. 250 mm/240 mm Width (blowing head/control unit): .............................. 150 mm/250 mm Height (blowing head/control unit): ................................ 220 mm/80 mm 1) Depending on type of microduct and cable. 2) Cooled and dried air. Gabocom HF Fremco Microow SNR 7x1,5 A-D 2Y 1x12 SNR 1,5 12 Ohne Grün 2,6 Kaeser gerieft °C 23°C nein SpeedNet-System Einblas - Protokoll Bauvorhaben Nr. Fresco Deutsche telecom test 2018-05-30 Datum, Startzeit: 2018-05-30 10:58 Streckenabschnitt / NVt Ellehammervej 14 Firma Femco Einbläser: Jacob kühn Bemerkungen Aliens ok Rohrparameter Kabelparameter Einblasgerät/ Kompressor Hersteller: Hersteller: Einblasgerät: Rohrverband: Bezeichnung: + Lubricator [ nein ] Rohr: Faserzahl: Gleitmittel: Farbe-Kennung: Kabel-Durchmesser: Kompressor: Rohrinnenwand: Meterzahlen: Start: 4510 | Ende: 4804 + Ölabscheider [ nein ] + Nachkühler [ nein ] SNR-Temperatur: Kabel-Temperatur: Kabel-Einblaskappe: Zusammenfassung Strecke: 294 Einblaszeit: 0:08:46 Wetter: 34.5°C, 29.8%RH Ort(GPS): 57.448396667, 10.492838333 Each job will end with a full report that ensures that the quality is 100% documented. This will minimize the risk of costly errors. The MicroFlow LOG is of course equipped with the unique well-known protection technology that stops the machine if the fiber cable meets resistance. Any stop is registered by a sensor and the motor stops. The machine will also stop automatically if the motor exceeds the preset maximum torque level. In both cases the machine stops immediately so the fiber cable does not get damaged. Fremco A/S · Tel. +45 72 30 12 13 · www.fremco.dk 110/230 V The Microflow LOG is a fiber blowing machine with a data driven decision tool which minimizes the risk of costly errors due to wrong blowing techiques. Online diagnostics can show you how the machine operates and how to improve the utilization. HIGHLIGHTS • Compatible with OptiCloud • Deutsche Telekom Template • The Log template can be individually adapted • Easy connection to controller • Verification of blowing quality (e.g. pressure, length, recommended speed, stress on cable etc) • Remote support BENEFITS • Confirmation of job, location and time via invoice • Quality based documentation such as stress on the cable, comparison of different types of cable and if predetermined blowing limitation are exceeded. • Best practice for blowing teams • Utilization • Maintenance & Service Recommendation of the fiber blowing machine Approved by: for DTAG ZTV 40-II Valid from September 23, 2019.

MICROFLOW LOG - sw2189.smartweb-static.com · cable, comparison of different types of cable and if predetermined blowing limitation are exceeded. • Best practice for blowing teams

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MICROFLOW LOG - sw2189.smartweb-static.com · cable, comparison of different types of cable and if predetermined blowing limitation are exceeded. • Best practice for blowing teams

MICROFLOW LOG

Cable blowing machine for FTTH FIBERS (EPFU) AND MICRO CABLES

SPECIFICATIONSItem no.: ................ .................................................. 101-171001001Fiber/cable diameter: ...................................................... 0.8 - 6.5 mmMicroduct diameter: ........................................................... 4 - 16 mmBlowing distance1: .......................................................... Up to 2500 mBlowing speed1: .......................................................... Up to 90 m/min.Recommended pressure and airflow2: ........ 8-16 bar (200-500 l/pr. min.)Weight (including control unit): .................................................. 13.2 kgLength (blowing head/control unit): ............................. 250 mm/240 mmWidth (blowing head/control unit): .............................. 150 mm/250 mmHeight (blowing head/control unit): ................................ 220 mm/80 mm1) Depending on type of microduct and cable.2) Cooled and dried air.

Gabocom HF Fremco Microflow

SNR 7x1,5 A-D 2Y 1x12

SNR 1,5 12 Ohne

Grün 2,6 Kaeser

gerieft

°C 23°C nein

SpeedNet-System Einblas - Protokoll

Bauvorhaben Nr. Fresco Deutsche telecom test 2018-05-30 Datum, Startzeit: 2018-05-30 10:58

Streckenabschnitt / NVt Ellehammervej 14

Firma Femco Einbläser: Jacob kühn

Bemerkungen Aliens ok

Rohrparameter Kabelparameter Einblasgerät/ Kompressor

Hersteller: Hersteller: Einblasgerät:

Rohrverband: Bezeichnung: + Lubricator [ nein ]

Rohr: Faserzahl: Gleitmittel:

Farbe-Kennung: Kabel-Durchmesser: Kompressor:

Rohrinnenwand: Meterzahlen: Start: 4510 | Ende: 4804

+ Ölabscheider [ nein ] + Nachkühler [ nein ]

SNR-Temperatur: Kabel-Temperatur: Kabel-Einblaskappe:

Zusammenfassung

Strecke: 294 Einblaszeit: 0:08:46 Wetter: 34.5°C, 29.8%RH Ort(GPS): 57.448396667,10.492838333

Each job will end with a full report that ensures that the quality is 100% documented. This will minimize the risk of costly errors.

The MicroFlow LOG is of course equipped with the unique well-known protection technology that stops the machine if the fiber cable meets resistance. Any stop is registered by a sensor and the motor stops. The machine will also stop automatically if the motor exceeds the preset maximum torque level. In both cases the machine stops immediately so the fiber cable does not get damaged.

Fremco A/S · Tel. +45 72 30 12 13 · www.fremco.dk

110/230 V

The Microflow LOG is a fiber blowing machine with a data driven decision tool which minimizes the risk of costly errors due to wrong blowing techiques. Online diagnostics can show you how the machine operates and how to improve the utilization.

HIGHLIGHTS• Compatible with OptiCloud• Deutsche Telekom Template• The Log template can be individually adapted• Easy connection to controller • Verification of blowing quality (e.g. pressure, length, recommended speed,

stress on cable etc)• Remote support

BENEFITS• Confirmation of job, location and time via invoice• Quality based documentation such as stress on the

cable, comparison of different types of cable and if predetermined blowing limitation are exceeded.

• Best practice for blowing teams• Utilization • Maintenance & Service Recommendation of the fiber blowing machine

Approved by:

for DTAG ZTV 40-II

Valid from September 23, 2019.

Page 2: MICROFLOW LOG - sw2189.smartweb-static.com · cable, comparison of different types of cable and if predetermined blowing limitation are exceeded. • Best practice for blowing teams

Fremco A/S · Tel. +45 72 30 12 13 · www.fremco.dk

MicroFlow V5 adaptor plates

All MicroFlow machines must be fitted with adaptor plate set. All adaptor plates are replaceable, making the machine more flexible when blowing different sizes of cable. The set consists of an upper and a lower plate, which together form a compact airtight unit around duct and fiber.

Adaptor plate set includes:• Sensor arm kit or super straight kit - size optional.• Drive wheels with O-rings.• Inlet guides.

MICROFLOW TOUCH & LOGADAPTOR PLATES

PLEASESTATE

FIBER/CABLE SIZE

AND DUCT SIZEWHEN

ORDRERING!

The adaptor plates are available in different sizes for 5-16 mm duct OD and 0.8-6.5 mm fiber/cable.

Inlet guides:1.5-6.8 mm.

O-rings fordrive wheels:2.0-6.5 mm.

MicroFlow V5gaskets areavailable in different sizes for 5-16 mm duct OD and 0.8-6.5 mm fiber/cable.