View
225
Download
2
Tags:
Embed Size (px)
Citation preview
significant signal degradationin the presence of
measurements using FSIPrecise distance
P. A. Coe, A. Mitra, D. F. Howell & R. B. Nickerson
ATLAS Group Particle Physics University of Oxford
O verviewW hat is Frequency Scanning Interferom etry?
H ow is FS I used to m easure d istance?
W hat effects degrade the signals?
H ow can the effects be dealt w ith?
Outlook and future work.
W hy is FS I needed inside a partic le tracker?
emi onductor rackerS c T
ATLAS
Monitored using GeodeticGrids of length measurementinterferometers
Approx 800Grid Line Interferometers
Lasers
ReferenceI nterferom eters
SplitterTree
M ainD elivery
F ibre
Beam -S plitter
RadHard
Fibres
S CT S TRUCTURE
J ewel J ewelGLIPhotodetector
Retroreflector
To other GLI s
Interferometer design means returnsAre only -70 dB to -90 dB!
Reference Phase Measurem ent
Carre algorithm (110 steps)O
M odulate Long R eference Interferom eterusing PZT m ounted m irror
PZT voltage
PZT
12.5 m mDiam eter Mirror
LONG REFERENCE I NTERFEROMETER
25 m m Diam eter
Mirror
Non- polarising beam - splitter cube
PHOTODI ODEwith PI NHOLE
980 1000 1020 1040 1060 1080
-4
-3
-2
-1
0
1
2
3
4 E
xtr
act
ed
Ph
ase
/ r
ad
ian
s
Phase stepping cycle
(S ingle Laser)
Phase unwrapping
-800 -600
0
500
1000
1500
2000
2500
Inte
nsity
Laser Freq Shift / a .u.
To measure GLI phase shift…
(Reference phase)
How is sinusoidal fit chosen?
Minimise Fit Quality
SearchFor minimausing MINUIT
Think modulo 2
Signal degrading effects in ATLAS
• Low signals – 800 hungry interferometers to be fed
• Potential for reflections off many surfaces inside ATLAS
• Potential for mechanical vibrations (& turbulence)
Low signal power
Low signal power reduces depth of minimum in fit quality
In the presence of spurious reflections…
…other minimaappear
Measurement precision unaffected by spurious reflections
4 spuriousReflectors added
Vibration
More vibration….. Fit collapses!!
To Stop the Fit Collapsing
Redefine the WEIGHT inthe fit quality to penalise decreasein fringe amplitude
New WEIGHT = Fringe amplitude 1/2
Is there a problem at 400 nm = 0.5?or was it just because two subscans are not enough?
Increase peak to peak vibration amplitude to 1.8 m (>2)and use 6 subscans
At 70 Hz
Looks very promising…
CONCLUSIONS
• Initial investigations into the effects of low SNR, spurious reflections and vibrations show that…
• …FSI is a robust technique for precise distance measurements.
• Further work needed to improve linking and investigate data analysis alternatives and their potential benefits, eg FFT.