45
Network, Cable & Electrical Testing ON-LINE www.rssingapore.com 93 OM = Order Multiple 2239 Electrical Installation Software 2239 Megger Electrical Installation Test Equipment 2239 ISO-TECH Electrical Installation Test Equipment 2242 Martindale Electrical Installation Test Equipment 2243 16th Edition Test Equipment 2244 InstalTest Installation Testers 2245 SANWA Insulation Testers 2245 Chauvin Arnoux Electrical Installation Test Equipment 2246 Fluke Electrical Installation Test Equipment 2246 Earth Testing 2246 Clampmeters 2249 Power Measurement 2258 Energy Monitoring 2262 Portable Appliance Testing 2262 92 Lab Equipment, Environmental Monitoring & Calibration 2182 91 Bench Power Supplies 2172 94 Inspection & Mechanical Measurement 2283 Test & Measurement Network, Cable & Electrical Testing - contents 95 Multimeters 2310 96 Oscilloscopes 2340 97 Logic Analysers & Signal Generation 2353 98 Test Leads & Accessories 2361 Flash/Hi-Pot Insulation Testers 2266 Cable Fault Locators 2267 Cable and Metal Detectors 2268 Mains Socket Testers 2269 Phase Rotation Testers 2270 Voltage Level Indicators 2271 Mains Voltage Indicators 1778 Automotive Voltage Indicators 2273 Magnetic Field Indicators 2273 Cable Test Equipment 2273 Network Test Equipment 2278 Telecom Test Equipment 2279 2236 www.nguyenxuong.com

Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple

2239

Electrical Installation Software 2239

Megger Electrical InstallationTest Equipment

2239

ISO-TECH ElectricalInstallation Test Equipment

2242

Martindale ElectricalInstallation Test Equipment

2243

16th Edition Test Equipment 2244

InstalTest Installation Testers 2245

SANWA Insulation Testers 2245

Chauvin Arnoux ElectricalInstallation Test Equipment

2246

Fluke Electrical InstallationTest Equipment

2246

Earth Testing 2246

Clampmeters 2249

Power Measurement 2258

Energy Monitoring 2262

Portable Appliance Testing 2262

92 Lab Equipment,Environmental Monitoring &Calibration 2182

91 Bench Power Supplies 2172 94 Inspection & MechanicalMeasurement 2283

Test & MeasurementNetwork, Cable & Electrical Testing - contents

95 Multimeters 2310

96 Oscilloscopes 2340

97 Logic Analysers & SignalGeneration 2353

98 Test Leads & Accessories 2361

Flash/Hi-Pot Insulation Testers 2266

Cable Fault Locators 2267

Cable and Metal Detectors 2268

Mains Socket Testers 2269

Phase Rotation Testers 2270

Voltage Level Indicators 2271

Mains Voltage Indicators 1778

Automotive Voltage Indicators 2273

Magnetic Field Indicators 2273

Cable Test Equipment 2273

Network Test Equipment 2278

Telecom Test Equipment 2279

2236

www.nguyenxuong.com

Page 2: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Introducing the world’s first truly flexible clamp meter: The Fluke 376 with iFlex™.

Ask us about the FULL LINE of innovative Fluke clamp meters.

.

www.nguyenxuong.com

Page 3: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

t� 5IF�NPTU�VTFE�BOE�USVTUFE�UFTUFS�NPSF�UIBO���CJMMJPO�DPQQFS�MJOLT�DFSUJGJFE

t� 3FEVDF�DPQQFS�DFSUJGJDBUJPO�DPTUT�VQ�UP�����QFS�ZFBS

t� 1FSGPSNT�GJCFS�DFSUJGJDBUJPO��Y�GBTUFS��

¦�����'MVLF�$PSQPSBUJPO��"MM�SJHIUT�SFTFSWFE��

DTX CableAnalyzer™ Series

Tested.Trusted.

www.nguyenxuong.com

Page 4: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Megger Insulation & Continuity Testers

Megger Combination Testers

Megger Multifunction Installation Testers

Electrical Installation CertificationSoftware

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Visit our website for additional price information and exciting promotions

MIT480 Series Telecom Insulation& continuity test

LRCD220 Loop & RCD Tester

Megger MFT1700 Series

Contractor PAT & ElectricalCertification SoftwarePowersuite Professional Contractor offers all the features of PowerSuite

Lite with the addition of a data based client, assets and results

management database for managing 17th Edition electrical and Portable

Appliance test results. All records and downloaded data is allocated to the

appropriate customer on which a number of reports can be run

The LRCD200 series tester combines an Earth loop impedance

tester with an RCD tester. The loop tester is a non-tripping test

suitable for systems protected with 30mA or larger RCDs. The RCD

testing supports 10mA to 1000mA RCDs with the full range of tests.

Ramp testing provides a trip current test for the testing of nuisance

tripping RCDs. Suitable for use on 110V or 3 phase

supplies.,Designed to meet the tough environment of site work, the

instruments are rubber armoured, have a built-in protective front

cover, and meet the requirements of BS7671, IEC1010 and

BSEN61557. All instruments are IP54 weatherproof. The combined

instrument offers all the test functions necessary for live electrical

Telecommunication insulation and continuity testers developed to meet the

special requirements of telephone line testing, as well as the requirements of

electrical contractors and industrial testing to CATIV 600V. All instruments meet

TNV3 as well as IEC1010, HD384 and BSEN61557. The insulation test inhibit

voltage has been raised to 75V to overcome interference between cables

experienced at lower voltages, compared to 50V for standard cable testing.

Work in real certificates and forms

Client and results database manages links between customers and their

test results

Download test results from Megger downloading PAT testers, Megger

downloading electrical installation testers and third party test equipment

or direct data entry to certificates

Real time results transfer via Bluetooth with Megger MFT1553 electrical

installation tester

Import company logo and add header page to customise certificates for

testing requirements, in a simple and cost effective instrument.

All models:Complies with EN 61010-1 CATIV 600V safety rating

200mA & 20mA Continuity testing

Insulation test voltage display

75V test inhibit

TRMS and DC Voltage measurement

Dual Digital Display and Analogue bar-graph

Alkaline or NiMH rechargeable battery operation

Multifunction tester for all 17th

Edition and Part P testing

applications

2-wire no-trip & high current loop

testing

Auto-start tests on continuity and

loop resistance – no need to push

the button

Dual display shows loop resistance

and fault current results

simultaneously

Dual test buttons for left or right-handed operation

Weatherproof to IP54

Input protection against accidental connection to live circuits

CAT IV 300V safety standard

a professional appearance

Print on plain paper or pre-printed forms

Extensive range of certificate formats and supports IEE, NICEIC, ECA, SELECT and ELECSA and BS

electrical test certificates

Full range of PAT testing certificates including repairs cerificates

Reports module generates a wide range of reports for electrical installation testing and PAT testing.

Project billing certificates and reports

Digital imaging module allows picture import for increased clarity in reports

Organiser module for scheduling workload, site work and retesting etc. with graphical diary

Extended forms offer alternative and extra certificate formats including filling stations and security

systems, ensuring there is a certificate to meet your requirements

Built-in protective front cover

Tough rubber armoured case

Weatherproof to IP54

High current loop testing

Phase to phase loop testing

Auto RCD testing

1000mA RCD test

Phase rotation

110V, 230V and 415V operation

Backlit display

IP54 weatherproof housing

Test lock allows the insulation test to be held on indefinitely

MIT480 specific features50V & 100V insulation testing

100Gohms insulation range

MIT481 additional features50V, 100V, 250V, 500V, 1000V insulation tests

200Gohms insulation range

Leakage current display

kΩ resistance measurement

Timer, PI and DAR insulation tests

Insulation limit alarms

0.1nF to 10uF Capacitance measurement

Cable length calculated from an adjustable cable capacitance reference (default 50nF/km).

Test result storage (>1000)

MIT485 additional featuresResult download

Bluetooth capability (requires Bluetooth enabled PC or USB plus Bluetooth adaptor)

Note: RS is an authorised Megger distributor. Purchased though RS this product is eligible for the

Megger extended 3 Year warranty

Note: System Requirements: Pentium IV PC running XP or Vista operating system; 128MB RAM

(Min); 100MB hard disk space; CD-ROM drive; COM1 RS232 port (or USB port with USB to RS232

adaptor) for use with downloading PAT testers; Bluetooth for use with Megger MFT1553

Supplied with: User Guide CD, 3-wire test lead with croc clips, Mains plug test lead, printed quick-

start guide, hard carry-case, 8 AA batteries

Stock no. Price per OM S$ S$ S$

667-8359 unit 1+ 1090·00

Supplied with: Durable hard carry case, instructions, 3 wire test lead with crocodile clips, BS1363

mains socket test lead, 8 off AA alkaline batteries.

MFT1710 MFT1720 MFT1730

Voltage & frequency 600V, 400Hz 600V (RMS),400Hz

600V (RMS), 400Hz

Polarity � � �

Insulation resistance testvoltages

250, 500 V 250, 500, 1000 V 100, 250, 500, 1000 V

Adjustable insulation alarm limits � �

Continuity Test Current 200 mA 15mA / 200mA 15mA / 200mA

2 Wire No Trip & High CurrentLoop Test with PFC

� (20KA PFC) � (40KA PFC) � (40KA PFC)

Phase to Phase Loop Test(480V) � �

RCD Test Range 100 - 280V45 to 65Hz

50 - 500V45 – 65Hz

50 - 500V45 – 65Hz

RCD Auto Test & programmable tripping currentlevel

� �

RCD ramp Test � � �

RCDs Type Tests AC, A (G&S) AC, A (G&S) AC, A (G&S)

3 Phase RCD Test � �

3 Wire Earth resistance �

Phase Rotation � �

Memory (1000 measurements) �

Bluetooth Interface �

Remote Switched Probe Included Included

Power 8 x AA alkalinebatteries

8 x AA alkalinebatteries

8 x AA NiMH rechargeable batterieswith charger included

Supplied with: Hard carry case, rubber boot with stand, silicone test lead set, SP5 remote switch

probe, 5 off AA alkaline batteries & instructions (CD-ROM).

Stock no. Price per OM S$ S$ S$

712-5749 unit 1+ 1441·00

Description Stock no. Price per OM S$ S$ S$

MFT1720 705-4751Sa unit 1+ 1759·00

MFT1730 705-4754Sa unit 1+ 2108·00

Applications

MIT480 MIT481 MIT485

Application Telecommunications

Insulation Voltage range

50V, 100V X X X

250V, 500V, 1000V X X

Insulation range 10GΩ 200GΩ 200GΩ

Leakage current display X X

Insulation test voltage display X X X

Continuity

Variable current limit 20mA or 200mA X X X

K ohms range to 999 K ohms X X

Measurements

Default voltmeter TRMS to 600V X X X

Frequency Hz- 40 to 400 Hz X X

Live circuit inhibit 75V X X X

Capacitance (0.1nF to 10μF) X X

Distance by Capacitance X X

Features

TNV3 compliant X X X

Switched remote probe X X

Backlight display X X X

Timer function (t PI DAR) X X

Storage and downloading

Test result storage X X

2239

www.nguyenxuong.com

Page 5: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple a New product to range

MIT230 Insulation & ContinuityTester

MIT220 Insulation & ContinuityTester

BM12 Multi-Voltage Insulation &Continuity Tester

MIT 300 Series Insulation &Continuity Testers

The MIT230 is one of the smallest insulation testers available on the market

today. With options of a two voltage tester to a three voltage instrument, the

MIT230 instruments offer a range of safety and operation features.

A range of insulation testers that meet the relevant requirements

of EN61557, BS7671, HD 384, IEC 364 and VDE 0413 for

applications in all aspects of electrical contracting, building

maintenance, testing, inspection and servicing.

A battery powered multi-voltage insulation and continuity tester

incorporating a voltage measuring range. The BM12 is an analogue

instrument designed to meet the requirements of the IEE

regulations for testing electrical installations, and additionally

meets specification VDE 0413. Suitable for use on motors,

generators, transformers, and switchgear, the BM12 handles

insulation test voltages of 100, 250, 500 and 1000 volts d.c.

The MIT200 is one of the smallest insulation testers available on the market

today. With options of a two voltage tester to a three voltage instrument, the

MIT200 instruments offer a range of safety and operation features.

20mm LCD display with true analogue response

Tough rubber armoured case with self contained display cover

that locks away underneath the instrument during use

Designed to hang comfortably around the neck for hands-free,

or for bench use

Automatic 200mA fast continuity test on connection to the

Insulation testing to 1000MΩ

Dual & triple test voltages models

Digital display with electronic analogue arc display helps to confirm

insulation condition & to monitor fluctuating readings not apparent on the

digital display

Continuity testing at 200mA down to 0.01ohms resolution

Automatic discharge of circuit under test

1mA test current at selected voltage range

Default voltmeter automatically switches in when the instrument is

connected to a circuit with an AC or DC voltage greater than 25V

Autoranging analogue arc scale shows only the scale in use

Insulation testing to 1000MΩ

Dual & triple test voltages models

Digital display with electronic analogue arc display helps to confirm

insulation condition & to monitor fluctuating readings not apparent on the

digital display

Continuity testing at 200mA down to 0.01ohms resolution

Automatic discharge of circuit under test

1mA test current at selected voltage range

Default voltmeter automatically switches in when the instrument is connected

to a circuit with an AC or DC voltage greater than 25V

Autoranging analogue arc scale shows only the scale in use

Tests to BS7671 413-04-04, 713-02, 713-03, 713-04, 713-06.

Live circuit warning above 25V, also inhibits insulation & continuity tests above 50V

Lead resistance compensation on continuity

Hands free continuity testing Auto power-down after 5 minutes

Complies with IEC 1010-1 safety standard installation Category III, 600V phase to earth

Conforms to EN61557-1

Tests to BS7671, 713-02, 713-03, 713-04, 713-06, 713-08, 413-04-04

Live circuit warning above 25V, also inhibits insulation & continuity tests above 50V

Lead resistance compensation on continuity

circuit

Lead resistance nulling on continuity allows for use of fused test probes

Automatic discharge of circuit under test

Safety input terminal interlock - prevents unsafe connection of test leads

Intelligent Safety System - even if connected to a live circuit whilst on continuity setting the tester

will remain safe and undamaged

Live voltage warning alerts the operator when a circuit voltage over 25V exists when insulation

testing

Safety lockout prevents the test from operating when the circuit voltage is > 50V

Continuity check - prevents a continuity test or buzzer test on a live circuit

3 phase safe - will not be damaged if connected across phases

Locking test button

Meets the requirement of BS EN 61010-1 for safe connection to a 440V Installation Category III

supply (600V Phase to Earth)

IP54

MIT310A

Dimensions (H x W xD)

128 x 180 x 125 mm Insulation testvoltages

100, 250, 500, 1 kV d.c.

Weight 1kg Terminal Current(ons/c) (insulationresistance)

1.9mA

Ranges Accuracy

Insulation resistance 0 to 2000MΩ (1mA) Insulation resistanceand continuityranges

Typically ± 1.5 of f.s.d.Conforms to VDE 0413 (parts 1and 4)

Continuity 0 to 4Ω (200mA) Voltage range ± 2.5 of f.s.d. Voltage 0 to 600V a.c. Batteries 6 x 1.5V cells IEC LR6 (AA)

Moving coil display

Stock no. Price per OM S$ S$ S$

616-661S unit 1+ 1820·00

Supplied with: 6 x AA alkaline batteries, test leads crocodile clips, carry case & instructions.

MIT320 benefits from the following additional features:

Model MIT220 Zero offset adjust 0 to 9.99ΩTest Voltage 250, 500V Continuity buzzer Operates <5ΩTest current onLoad

>1mA at minimum pass levels specifiedin BS7671, HD384, IEC364 & VDE0413 part1

Voltagemeasurementrange

25V to 600V @ 50/60Hz & dc

Insulation range 0.01MΩ to 1000MΩ on all ranges Accuracy 25V to 450V ac/dc ±(1% rdg +1d) 450V to 600V ac/dc ±(2% rdg +1d)

Measuringaccuracy

±(3% rdg +2d) to 10MΩ, ±(5% rdg +2d) to 100MΩ

Operatingtemperaturerange

-10 °C → +60 °C

Continuity Range 0.01Ω to 100.0Ω Battery life 3500 x 5 sec tests (typ) Open circuitvoltage

5V± 1V Dimensions /Weight

195 x 98 x 40 mm / 530g

Accuracy (20°C) <10Ω ±(3% rdg +2d) >10Ω ±(5% rdg +2d)

Result recall to screen X X

Bluetooth download X

Download software X

Backlit display and range selection ideal for low light environment

Selectable insulation alarm limit for fast go - no go testing

Selectable continuity alarm limit for fast go - no go testing

Resistance measurement range to 1 MΩ

SP3 switched probe supplied for one handed operation

SP1000 illuminated switched probe with ultra-bright LED light available separately

Description Stock no. Price per OM S$ S$ S$

MIT480 611-1285S unit 1+ 890·00

MIT481 611-1279S unit 1+ 1230·00

MIT485 611-1291S unit 1+ 1370·00

SP5 Switched Probe 611-1308 unit 1+ 76·00

BM200 Series Replacement Guide

Old BM200 Model RS stock no. BM Test voltage MIT220 RS 535-3185 MIT230 RS 535-3191

BM121 198-0294 250 � -

BM221 254-9658 500 � -

BM222 254-9664 500,1000 - �

BM223 254-9670 250,500,1000 - �

BM224 254-9686 500 � -

BM227 330-8379 250,500 � -

Supplied with: instructions, 2 wire test lead set with crocodile clips, 8 x AA alkaline batteries, neck

strap & carry case.

Stock no. Price per OM S$ S$ S$

535-3185S unit 1+ 610·00

Model MIT300 MIT310 MIT310A MIT320

Insulation ranges

250V Yes Yes Yes Yes

500V Yes Yes Yes Yes

1000V - Yes Yes Yes

Measuring range 10kΩ to 999MΩ 10kΩ to 999MΩ 10kΩ to 999MΩ 10kΩ to 999MΩ

Short Circuit Current 1.5mA nominal 1.5mA nominal 1.5mA nominal 1.5mA nominal

Test Current on Load@ min pass values of insulation(BS7671, HD384 & IEC364)

1mA 1mA 1mA 1mA

Accuracy (@ 20°C) ±3%, ±2 digits ±3%, ±2 digits ±2.5% of scalelength

±3%, ±2 digits

Insulation Limit Alarm 10kΩ to 1GΩ 10kΩ to 1GΩ 10kΩ to 1GΩ 10kΩ to 1GΩ

Continuity

Measuring Range 0.01Ω to 99.9Ω 0.01Ω to 99.9Ω 0Ω to 50Ω 0.01Ω to 99.9Ω

Open Circuit Voltage 5V ±1V 5V ±1V 5V ±1V 5V ±1V

Short Circuit Current 205 mA ±5mA 205 mA ±5mA 205 mA ±5mA 205 mA ±5mA

Zero Offset Adjust 0 to 9Ω 0 to 9Ω 0 to 0.5Ω 0 to 9Ω

Buzzer Operates @ <5Ω <5Ω <5Ω 1 Ω to 20Ω adj.

Buzzer Response time <20ms <20ms <100ms <20ms

Resistance (MIT320)

Measuring Range - - - 10Ω to 1MΩ

Open Circuit Voltage - - - 5V

Short Circuit Current - - - 200μA

Accuracy @ 20°C - - - ±3%, ±2 digits up to 100kΩ

Voltage

Measuring Range 0 to 600 Vac (50/60 Hz) or dc

0 to 600 Vac (50/60 Hz) or dc

0 to 600 Vac (50/60Hz) or dc

0 to 600 Vac (50/60 Hz) or dc

Accuracy @ 20°C dc or ac (50/60Hz)±1% ±2 digits

dc or ac (50/60Hz)±1% ±2 digits

±2.5% of scale length for 50/60 Hz

dc or ac (50/60Hz)±1% ±2 digits

Selection Guide

MIT300 MIT310 MIT310A MIT320

Resistance �

Voltage warning �

Default voltmeter � � �

Back-lit display �

Back-lit selector �

Auto power down � � �

Switched test probe �

Description Stock no. Price per OM S$ S$ S$

MIT300 Digital 516-7681S unit 1+ 550·00

MIT310 Digital 516-7697S unit 1+ 710·00

MIT310A Analogue 516-7704S unit 1+ 650·00

MIT320 Digital 516-7710S unit 1+ 830·00

2240

www.nguyenxuong.com

Page 6: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Megger Loop Testers

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

New products available online every week

LTW 300 Series

SP1 Switched Probe Accessory

Megger MFT1800 Series

MIT400 Series Digital Insulation &Continuity Testers

LTW315

For use with BM80/2, BMM80 and BMM503 Insulation and Continuity

Tester

All instruments meet IEC1010, HD384 and BSEN61557, and are sealed to

IP54 for weatherproof performance.

Easy to hold and comfortable to use, the large display provides the

unique combination of two digital readouts and an analogue arc.

All primary results are displayed in the larger digital display and

repeated on the analogue arc. Additionally, auxiliary test information

such as frequency, leakage current, Insulation or circuit voltage etc is

displayed in the smaller secondary digital display.

Rubber over-moulding combines the tough shock absorbing outer

protection with excellent grip, on a strong modified ABS housing,

providing an almost indestructible case.

Battery requirements are 5 AA batteries of either standard Alkaline

(supplied) or Nickel Metal Hydride (NiMH) rechargeable type.

All models feature:

Multifunction tester for electrical

installation testing in accordance

with VDE 0100

2-wire no-trip & high current loop

impedance testing

Auto-start tests on continuity and

loop resistance

Simultaneous display of loop

resistance and fault current results

Dual test buttons for left or right-

handed operation

Earth loop impedance testers to verify the loop impedance of a

live electrical circuit without the need to disconnect the

electrical supply. The LTW300 series instruments offer a safe

and easy 2 wire loop testing solution that does not trip 30mA

RCDs and can be used on a wide range of voltages.

Stock no. Price per OM S$ S$ S$

232-8827 unit 1+ 80·50

Backlit display

0.01Ω resolution

No-trip loop test on circuits with RCDs of ≥30 mA

3 phase circuits with RCD protection can be tested

Tests radial circuits where the circuit does not return to the

origin, even where only a phase and neutral contacts are

available.

10 second non trip loop test time with Auto test extension up

to a further 10 seconds if noise is detected, to improve the

Insulation testing to 1000V with Insulation test voltage display

Continuity testing at 200mA down to 0.01ohms

Alternative 20mA test current

AC/DC Voltage measurement

True RMS Measurement to 600V

50V Live circuit test inhibit

Complies with EN61010-1 CATIV 600V

IP54 weatherproof housing

Hard carry case

Optional SP5 switched probe with remote test button for single-handed operation

Hands free continuity testing Auto power-down after 5 minutes

Complies with IEC 1010-1 safety standard installation Category III, 600V phase to earth

Conforms to EN61557-1

Tests to BS7671, 713-02, 713-03, 713-04, 713-06, 713-08, 413-04-04

Switched probe for ease of use

Weatherproof to IP54

Input protection against accidental connection to live circuits

CAT IV 300V safety standard

Supplied with: Durable hard carry case, silicone test lead set, AA alkaline batteries & instructions.

Note: German version

accuracy of the test

High current loop testing for supplies that do not have an RCD fitted

AUTO START will start the loop test running as soon as the test leads are connected; no need to

press the test button means much safer testing

Supplied with: 6 x AA alkaline batteries, test leads crocodile clips, carry case & instructions.

MIT400 Series Comparison table

MIT400 MIT 410 MIT420 MIT430 MIT40X Insulation Test Voltage

10V to 100V adjustable �

50V, 100V � � �

250V, 500V, 1000V � � � �

Insulation Resistance

100Gohm range � � �

200Gohms range � �

Leakage current display � � � �

Voltage/Frequency

Frequency � � �

Features

Remote switched probe � � �

PI and DAR timed functions � � �

Capacitance measurement � �

Storage and downloading

Test result storage � �

Result recall to screen � �

Bluetooth download & software �

MFT1815 MFT1825 MFT1835

Voltage & frequency 600V, 400Hz 600V (RMS),400Hz

600V (RMS), 400Hz

Polarity � � �

Insulation resistance testvoltages

250, 500 V 250, 500, 1000 V 100, 250, 500, 1000 V

Adjustable insulation alarm limits � �

200mA Continuity Test � � �

Loop Impedance Testwith PFC

� (20kA PFC) � (40kA PFC) � (40kA PFC)

Phase to Phase Loop Test(480V) � �

RCD Test Range 100 - 280V45 to 65Hz

50 - 500V45 – 65Hz

50 - 500V45 – 65Hz

Auto RCD Test � �

RCD ramp Test � � �

RCDs Type Tests AC, A (G&S) AC, A (G&S) AC, A, B (G&S)

3 Phase RCD Test � �

3 Pole & Stakeless Earth resistance �

Phase Rotation � �

Memory (1000 measurements) �

Bluetooth Interface �

Power 8 x AA alkalinebatteries

8 x AA alkalinebatteries

8 x AA NiMH rechargeable batteries withcharger included

General Dimensions/ weight 220 x 92 x 50 mm, 775g Battery life 2200 insulation tests with duty cycle of

5 sec ON /55sec OFF @ 1000Vinto1Mohm

Insulation Resistance

Basic Full ScaleAccuracy

± 3% ± 2 digits Measurement 0,01 kΩ to 1000 kΩ (0 to 1 MΩ onanalogue scale)

Insulation measurement resolution Accuracy ± 3% ± 2 digits Digital 0.01MΩ Digital Voltage range

Analogue range 1GΩ full scale 0 to 600Vdc ± 2% ± 2 digits Short CircuitCurrent

2 mA +0% -50% 10mV to 600V TRMSsinusoidal (40 to400Hz)

±2% ±2digit

Test Current onload

1mA at min. pass value of insulationspecified in BS7671, HD384 and IEC364,2mA max.

Default Voltmeter Operates at >25 volts a.c. or d.c. on anyrange except OFF

EN61557 Operatingrange

0,10MΩ to 1,00GΩ Frequency 40-450Hz (40Hz - 99,9Hz ±0.5% ± 1digit)

Continuity Capacitance (MIT420 & MIT430)

Measurement 0,01 Ω to 99,9 Ω (0 to 100 Ω onanalogue scale)

Measurementrange

100 pF to 10 uF

Accuracy ± 3% ± 2 digits (0 to 100Ω ) Accuracy ± 5.0% ± 2 digits Test current: 200mA (–0mA, +20mA) (0.01 Ω to 9.99

Ω) 20mA(±1mA ) (10.0Ω to 99.9Ω) Distance by capacitance: (MIT420 & MIT430)

Lead resistancezeroing

Up to 9,00 Ω Arithmetic conversion from capacitance measurement.

Buzzer Variable limit 1Ω, 2Ω, 5Ω, 10Ω, 20Ω Capacitance range 40nF/m to 60nF/m (default 50nF/m)

Model MIT230 Zero offset adjust 0 to 9.99ΩTest Voltage 250, 500V, 1000V Continuity buzzer Operates <5ΩTest current onLoad

>1mA at minimum pass levels specifiedin BS7671, HD384, IEC364 & VDE0413 part1

Voltagemeasurementrange

25V to 600V @ 50/60Hz & dc

Insulation range 0.01MΩ to 1000MΩ on all ranges Accuracy 25V to 450V ac/dc ±(1% rdg +1d) 450V to 600V ac/dc ±(2% rdg +1d)

Measuringaccuracy

±(3% rdg +2d) to 10MΩ, ±(5% rdg +2d) to 100MΩ

Operatingtemperaturerange

-10 °C → +60 °C

Continuity Range 0.01Ω to 100.0Ω Battery life 3500 x 5 sec tests (typ) Open circuitvoltage

5V± 1V Dimensions /Weight

195 x 98 x 40 mm / 530g

Accuracy (20°C) <10Ω ±(3% rdg +2d) >10Ω ±(5% rdg +2d)

Description Stock no. Price per OM S$ S$ S$

MFT1815 (German) 704-0474a unit 1+ 1897·00

MFT1825 (German) 704-0478a unit 1+ 2334·00

MFT1835 (German) 704-0487a unit 1+ 2893·00

Description Stock no. Price per OM S$ S$ S$

MIT400 535-3113S unit 1+ 710·00

MIT410 535-3129S unit 1+ 820·00

+ RS Cal. 535-6421S unit 1+ 1260·00

MIT420 611-1257S unit 1+ 960·00

MIT430 611-1263S unit 1+ 1070·00

MIT40X 611-1314S unit 1+ 900·00

Description Stock no. Price per OM S$ S$ S$

MIT230 Tester 535-3191S unit 1+ 670·00

MIT230 + RS Cal. 535-6487S unit 1+ 1250·00

2241

www.nguyenxuong.com

Page 7: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

ISO-TECH Insulation & Continuity Testers

Megger RCD Tester

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple a New product to range

IIT2302 Digital Insulation/Continuity Tester

IIT2301 Analogue Insulation/Continuity Tester

IIT1601 Digital InsulationTester

RCDT310 & RCDT320 RCD Testers

Microprocessor-controlled, triple-voltage insulation tester

with high performance circuitry for fast data processing and

rapid display of readings. 200mA short-circuit current in

accordance with BS7671 regulations continuity test.

250V, 500V, & 1000V insulation test voltages

200 mA continuity short circuit current, fuse protected to comply

with BS7671 Wiring Regulations

Backlit display

Live circuit audible & visible warning

Lock-down button

Ohms zero-adjust to null out test lead resistance

Complies with safety standard EN610101-1 CAT III 300V

Tests to BS7671 413-04-04, 713-02, 713-03, 713-06, 713-08

Large backlit 3¾ digit, 4000 count LCD with analogue

bargraph

Insulation resistance to 4000MΩ autoranging

250V, 500V & 1000V insulation test voltages

Continuity to 40Ω, 200mA test current

Low battery warning

Continuity beeper

Lock and hold facility

Auto power off

Meets the requirements of EN61557 and BS7671 / wiring

regulations

Safety to EN61010-1 600V CAT III

Digital continuity and insulation tester

250/500/1000V insulation test ranges (1mA)

20/200/2000 Ohm continuity ranges with 200mA test

current

Auto null

Bar graph indication of test voltage

Live circuit warning

Protects against accidental connection to live circuit

Supplied with: Test leads, crocodile clips, instruction manual and 6 AA alkaline batteries.

Supplied with: Test leads and batteries.

Two RCD testers that comply with

EN61557 for testing, measuring or

monitoring of protective measures.

Insulation Test Ranges Open CircuitVoltage Output

4 to 9Vdc

DC Test Voltage 250V, 500V, 1000V Short CircuitCurrent Output

200mA min

Measuring Range(Mid Full Scale )

0 to 100MΩ (1MΩ)0 to 200MΩ (2MΩ)0 to 400MΩ (4MΩ)

Accuracy ± 3% of scale length

Output Current 1mAdc General

Accuracy 5% Withstand Voltage 5000Vac for 1 minute between electricalcircuit and case

Continuity Test Ranges Dimensions (H x Wx D)

175 x 115 x 86mm

Measuring Ranges0 to 2Ω, 0 to 20Ω Weight 640g

General

Power 12 Vdc (8 x 1.5 V AA)

Safety EN61010-1 600 V CAT III

Memory (Test results) Data hold function

Dimensions 77 x 140 x 190 mm

Weight 900g

AC Voltage

Voltage Range 0 → 600 V

Voltage Resolution 1 V

Voltage Accuracy ±(1.5 % rdg + 3 digits)

Overload Protection 750 Vrms

Insulation

Insulation Resistance Impedance Range 0 - 4000 MΩ

Resolution 1kΩ

Accuracy ±(3% rdg + 3 digits)

Output Short Circuit current 1.7 mA Max.

Continuity

Range 400Ω

Accuracy ±(1% rdg + 5 digits)

Overload protection 220Vrms

Continuity Beeper

Resolution 0.1Ω

Operation resistance <40Ω

Overload protection 220Vrms

Tests 30mA, 100mA, 300mA and 500mA rated RCDs

1/2x I, I, 5x I tests standard, DC and selective RCDs

0° or 180° polarity tests on all RCDs

Selective breakers have a time delay in tripping. When

selected, trip test times are extended and a 30s delay is

allowed between the measurement of the fault voltage

and the application of the test current

Selectable touch voltage inhibit and touch voltage display

on the analogue bargraph

Automatic capacitive circuit discharge on release of test button

Lock-down test button for continuous operation

Complies with safety standard EN61010-1 CAT III 300V

Description Stock no. Price per OM S$ S$ S$

IIT1601 697-3724S unit 1+ 636·00

PFC Display up to 20kA

Voltage and frequency measurement

110Vac systems including 110V centre tap to earth (55V phase to earth) can be tested on the

secondary winding.

IP54 Weatherproof case

Optional 10A fused 2 wired test leads and crocodile clip set

Complies with IEC61010-1 300V CATIV safety standard and meets EN61557

300Vac (25 to 45Hz) voltage measurement range

Clear 20mm high digit LCD display with analogue arc bargraph

Tough rubber armoured case with self-contained display cover that locks away underneath the

instrument during use

Safety input terminal interlock - prevents unsafe connection of test leads

Safety lock-out prevents the test from operating when the circuit voltage is >300V

Stock no. Price per OM S$ S$ S$

530-5681S unit 1+ 460·00

RCDT320 model additional features

Note: RS is an authorised Megger distributor. Purchased though RS this product is eligible for the

Megger extended 3 Year warranty

Supplied with: Test lead set with crocodile clips, mains socket test lead, 8 AA alkaline batteries, hard

carry case and instructions.

10mA/1A RCD extended test capability

Backlit display and range selection ideal for low light environments

Ramp Test measures & displays the actual trip current of an RCD. Ideal for diagnosing nuisance

tripping of RCDs

Auto testing allows remote testing from the RCD under test. The RCDT320 will automatically

perform a 1/2 I, I and 5I test at both 0°and 180°. When the RCD trips the user resets it and the tester

proceeds to the next test automatically. All results are displayed at the end of the test

25 to 450Hz Frequency measurement range

Optional 2-wire test leads supplied

Voltage measurement

(ac only) 50V to 440V Accuracy ±2% ±1V Range 25Hz to 99.99Hz Accuracy ±0.1Hz A warning will be shown if applied voltage exceeds 440VDamage will occur if applied voltage exceeds 600Vrms Loop testing

No-trip loop and high current loop test

Source voltage LTW315: 100V to 280V (50Hz)LTW325: 50V to 440V (50Hz)

Display range 0.01Ω to 2000ΩAccuracy ±5% ±0.03ΩNominal test current No-Trip loop test 15 mA (at nominal 230Vac supply) High current loop test 4 A (at

nominal 230 Vac supply) Operational range 0.30Ω to 1000ΩProspective Fault Current (PFC)

Prospective fault current Measured Source Voltage / Loop resistance Maximum range 40 kA; accuracy is derived from loop test and voltage measurement. Safety

EN61010 Designed to EN61010-1 ed2 2001-02 Designed for 300 volts to Earth Category IV, withPhase to Phase voltages to 440 Volts; Fuse protected to 600 volts rms ac

EN61557 Complies with the following parts of EN61557, Electrical safety in low voltage systemsup to 1000V ac and 1500V dc- Equipment for testing, measuring or monitoring ofprotective measures: Part1-General Requirements; Part3-Loop resistance

Power supply

Battery 8 x 1.5V cells IEC LR6 type (AA alkaline) Rechargeable 8 x 1.2V NiCd or NiMH cells Battery life 2000 consecutive tests Mechanical

Weight 1000g ±10% excluding test leads Dimensions 203 x 148 x 78 mm

3-phase safe - Meets the requirements of BSEN 61010-1 for safe connection to a 440V Installation

Category III supply (300V phase to Earth)

Weatherproof to IP54

Dimensions (WxHxD): 190 x 75 x 140mm; Weight 980g

Description Stock no. Price per OM S$ S$ S$

LTW315 198-435S unit 1+ 910·00

LTW325 198-457S unit 1+ 1070·00

Note: RS is an authorised Megger distributor. Purchased though RS this product is eligible for the

Megger extended 3 Year warranty

Supplied with: Instructions, Mains plug test leads, 8 AA alkaline batteries, neck strap.

Description Stock no. Price per OM S$ S$ S$

RCDT310 T RCD Tester 712-5737Sa unit 1+ 801·00

RCDT320 RCD Tester 712-5746S unit 1+ 880·00

RCDT320 RCD Tester,Aus version

163-974 unit 1+ 1050·00

2242

www.nguyenxuong.com

Page 8: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Martindale Insulation and ContinuityTesters

ISO-TECH RCD Tester

ISO-TECH Loop Testers

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Many more leading brands from over 2,500 suppliers available online

Triple Voltage Insulation andContinuity Tester MartindaleIN2102

Fused Test Lead Set for Loop &RCD Testers

IRT2310 RCD Tester with DCtest

IRT1900 Digital RCD Tester

IPT2300 PSC Loop ImpedanceTester with Anti-RCD TripFeature

18 RCD test current ranges

Tests RCDs and DC sensitive breakers 1⁄2 x, 1x, and 5x device ratings

Constant current control circuitry permits accurate readings

even when mains fluctuates by ±10% at 240V

0° and 180° phase selection

LED status lights for easy reading in dimly lit areas

LED indication of correct wiring status

Excessive overvoltage warning with lockout

Tripping time resolution 1ms

Complies with safety standard EN610101-1 CAT III 300V

A fully specified insulation tester with 250V, 500V & 1000V insulation tests that

provides accurate testing and is ideal for single handed operation. The output test

voltage is automatically displayed during testing and confirms that the desired test

voltage is being developed. The automatic zero adjust removes the resistance of

the leads and the test button can be set to be either latching, to give a permanent

output, or "press to test".

Custom microprocessor for highest accuracy and

reliability

3 LED’s for checking correct wiring status

0° and 180° phase angle switch permits quick tests and

consistent readings

Visual indication of reversed phase & neutral wiring at

socket

Digital read out of tripping time

20/200/2000Ω loop impedance test ranges

PSC measurement to 20kA

Anti trip technology allows 15mA low current loop testing

without bypassing all RCD types

25A high current test for fast tests in noisy environments

and where tripping RCDs is not a consideration.

Fully protected against phase to phase connection

Earth probe for testing exposed metalwork

Colour coded LEDs for instant check of correct wiring

status

Complies with BS 7671 wiring regulations

Complies with safety standard EN610101-1 CAT III 300V

This auxiliary test lead is designed for use with a wide range of earth loop

impedance testers and RCD testers. Both the red and black probes are

fused to enhance the safety of the user. A pair of shrouded safety croc-clips

are also available.

Supplied with: Test leads

Note: Colour may differ from that shown.

Description Stock no. Price per OM S$ S$ S$

Fused test leads 216-839 unit 1+ 74·50

Shrouded Crocodile Clips 218-100 unit 1+ 20·10

250V,500V & 1000V insulation test voltages

200mA continuity test current with buzzer below 30Ω

5,000 count backlit digital display with analogue bargraph

Displays test voltage

Auto HOLD of test readings

Automatic discharge of circuit under test

Live circuit audible and visible warning

“Press to test” or latching test button mode to give a permanent output on

Note: Colour may differ from that shown.

Tests to: BS7671: 413-04-04, 713-02, 713-03, 713-04, 713-06, 713-08-01

Supplied with: BS1363 mains socket test lead, distribution board fused test leads with earth lead

crocodile clip, instruction manual test lead pouch and 8 x AA alkaline batteries.

Supplied with: carrying strap, mains leads for BS1363 mains socket outlets, test lead pouch and

instruction booklet.

General Fault condition setting x1/2, x1 & x5 Safety EN61557; BS7671, EN61010-1 300V CAT III Fault trip time 2000ms, 40ms (x5) Display Type LCD Low set resolution 1ms (x1/2, x1) & 0.1ms (x5) Dimensions 70 x 130 x 180mm Trip time accuracy ± (1% rdg + Dgts) Weight 800g Operating voltage 230V ±10%, 50/60Hz Specification Withstand voltage 3000V AC for 1 minute Tripping current 10 / 20 / 30 / 100 / 300 / 500mA Operating temperature & humidity 0 to 40°C below 80% RH

insulation test

Automatic zero adjust removes the resistance of the test leads

Complies with BS EN 61557 (17th Edition) UK and international standards

Complies with EN61010 CAT III 600V

Supplied with: 6 AA alkaline batteries, instructions, carry case, test leads and crocodile clips.

Supplied with: Test leads, crocodile clips, instruction manual and 6 AA alkaline batteries.

Test current settings 10, 20, 30, 100, 300,500 mA

Test current Factors 1/2X, 1X, 5X, DC

Fault Trip Current Duration 2000ms (1/2X, 1X, DC)50ms (5X)

Rated system voltage 230V +10% , -15%; 50Hz

Trip time accuracy ±(0.6% + 4 digits)

Safety Rating EN61010-1 CAT III 300V

Stock no. Price per OM S$ S$ S$

697-3777S unit 1+ 490·00

Range Test Current Accuracy

Loop Normal 0 → 20Ω 25A for 10ms 3% rdg ±4 digits

Loop Normal 0 → 200Ω 2.3A for 40ms 3% rdg ±4 digits

Loop Normal 0 → 2000Ω 15mA for 360ms 3% rdg ±4 digits

Loop Anti-Trip 0 → 20Ω P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω

3% rdg ±6 digits

Loop Anti-Trip 0 → 200Ω P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω

3% rdg ±6 digits

PSC Normal 0 → 20kA 25A Determined by loop accuracy

PSC Normal 0 → 2000A 2.5A Determined by loop accuracy

PSC Normal 0 → 200A 2.3A Determined by loop accuracy

PSC Anti-Trip 0 → 20kA P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω

Determined by loop accuracy

PSC Anti-Trip 0 → 2000A P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω

Determined by loop accuracy

PSC Anti-Trip 0 → 200A P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω

Determined by loop accuracy

Voltage Measurement 100 → 300V 50Hz - 2% ±4 digits

Insulation Test Ranges Accuracy 0 to 20Ω ±(1.5% rdg +5 dgt)0 to 200Ω & 0 to 2000Ω ±(1.5%rdg +5 dgt)

DC Test Voltage 250V; 500V; 1000V General

Measuring Ranges 20MΩ 200MΩ 2000MΩ Withstand Voltage 5000Vac for 1 minute betweenelectrical circuit and case

Output Voltage on OpenCircuit

250Vdc ±10%500Vdc ±10%1000Vdc ±10%

Overload Protection

Output Current 1mAdc Safety Standard EN61010-1 CAT III 300V Output Short Circuit Current 1.3mA approx Dimensions (H x W x D) 175 x 115 x 86mm Accuracy 20MΩ / 200MΩ ± (1.5% rdg +5

dgt)2000MΩ ± (10% rdg +3 dgt)

Weight 640g

Continuity Test Ranges

Measuring Ranges Short Circuit Output Current 200mA min

Stock no. Price per OM S$ S$ S$

712-7036S unit 1+ 544·00

Stock no. Price per OM S$ S$ S$

712-7032S unit 1+ 740·00

IN2102 Accuracy ±3% ± 5 digit Display Digital Short circuit test current >200 mA Insulation Resistance Ranges 4/40/400/1000MΩ (250 V)

4/40/400/4000 MΩ (500 V)4/40/400/5000 MΩ (1000 V)

Resistance Range 0.1Ω to 1999 kΩ

Accuracy ±3% ±5 digit Accuracy ±3% ±5 digit Test voltage 250 V, 500 V, 1000 Vdc Test voltage 4 Vdc nom. Short circuit current <1.5 mA Voltage test range 0 → 600 V ac/dc Continuity Range 40Ω Accuracy ±3% ± 5digit

Stock no. Price per OM S$ S$ S$

530-5697S unit 1+ 420·00

Stock no. Price per OM S$ S$ S$

379-472S unit 1+ 700·00

2243

www.nguyenxuong.com

Page 9: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Combined Test Equipment

Kyoritsu Insulation Testers

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple a New product to range

4120A Kyoritsu Loop/PSC Tester

6010A 5-in-1 Multi Function Tester

6050 Loop/RCD Combi Tester

3007A Microprocessor DigitalInsulation & Continuity Tester

3125 High Voltage Insulation Tester

Large custom digital display readout

Custom microprocessor controlled for highest

accuracy and reliability

3 LEDs for checking correct wiring status

Wide range measurements from 500V to 5000V and

up to 1000GΩ

Large digital display with Bar Graph indication and

back light

Continuity and Insulation Testing

Bargraph to display insulation resistance

6050 Combi tester provides the ultimate in

Microprocessor technology offering Loop and RCD

tests with a comprehensive memory and facility for

downloading test results

Displays the value of external AC voltage along with flashing

symbol

Trac-Lok mode to conserve battery life on insulation and

continuity tests

Live circuit warning beeper

Backlight function

LOOP impedance 2000Ω range measurement is carried out

with a low test current (15mA) which will not trip the most

sensitive (30mA) RCDs

In-built Automatic RCD(ELCB)lock device. There is no need to

by-pass most passive RCD’s at distribution boards when

conducting LOOP or PSC tests

Direct reading of Prospective Short Circuit Current (PSC) and

earth fault currents

Safe voltage measurement function

Automatic lock-out if test resistor overheats

Visual indication of reversed phase-and-neutral wiring at

socket

Polarization Index measurement (PI)

Timer measurement function

Indication of Output voltage and Discharge voltage

Auto-discharge function and Voltage output warning function

Auto power off and Battery Check

Supplied with a line probe, earth cord, guard cord, pickle type cord,

alkaline batteries LR14 x 8 pcs and hard carrying case

Live circuit warning LED: Immediate illumination of

a warning lamp if the circuit under test is live

Auto Discharge:Allows fast and safe discharge of

LOOP Impedance 200/2000Ω range measurement is carried out

using a test current of 15mA which will not trip RCD’s rated at

30mA or greater

High resolution for low Loop Impedance (resolution of 0.01Ω) on

20Ω range

Direct reading of Prospective Short Circuit Current (PSC) and

earth fault current

RCD tests at 0 and 180 degree phase angle switch permit quick

tests and consistent readings

RCD Ramp test in order to indicate the actual tripping current of

RCD

Constant current source circuitry ensures that a fluctuating mains

voltage does not affect the accuracy of readings

Visual indication of correct wiring status and automatic lock-out

if test resistor overheats

Contact Voltage Reading (UC) with two selectable contact

voltage limits (25 and 50V)Supplied with: Pouch with test leads, shoulder strap

electrical energy stored in capacitive circuits following

testing

Integral overload protection on internal continuity and

insulation test circuitry

Standards: IEC 61010-1 CAT.III 300V, IEC 61557

Standards: IEC61010-1, CAT III 300V Pollution Degree 2,IEC61010-2-031, IEC61557-1/2/4

Standards: IEC61010-1 CAT.III 600V Pollution degree 2

Loop and RCD Testing

Supplied with: Pouch with test leads, shoulder strap and batteries

Standards: IEC61010-1 CAT.III 300V, IEC61557-1,-3, IEC61010-2-031 Pollution Degree 2,IEC60529-IP54

Range Insulaton resistance Voltagemeasurement

500 V 1000V 2500V 5000V AC/DC V

Measuring range 0.0-99.9MΩ 0.0-99.9MΩ 0.0-99.9MΩ 0.0-99.9MΩ

100-999MΩ 100-999MΩ 100-999MΩ 100-999MΩ AC/DC

1.00-1.99GΩ 1.00-9.99GΩ 1.00-9.99GΩ [50/60Hz]

10.0-99.9GΩ 10.0-99.9GΩ

100-1000GΩ

Accuracy ±5 % rdg ±3dgt ±5 % rdg ±3dgt ±5 % rdg ±3dgt ±5 % rdg ±3dgt(±20% 1000GΩ

range)

±2 % rdg ±3dgt

Short Circuit Current 1.3mA approx. -

Rated test current 1 to 1.2mA at0.5MΩ load

1 to 1.2mA at1MΩ load

1 to 1.2mA at2.5MΩ load

1 to 1.2mA at5MΩ load

-

Open circuit voltage 500Vdc +30%-0%

1000Vdc +20%-0%

2500Vdc +20%-0%

5000Vdc +20%-0%

-

Max display 999 Counts (1000 counts only at 1000GΩ) 630 Counts

Current consumption Approx.1000mA (During measurement) 25mA approx.

Withstand voltage 5320V AC for 5 seconds

Power supply DC 12V: 1.5V R14 × 8

Dimensions 205(L) × 152(W) × 94(D) mm, weight approx. 1.8kg

Insulation Resistance Ranges Output Voltage 7 - 12V DC Test Voltage 250V/500V/1000V Measuring Current 200mA DC min Measuring Ranges 20MΩ/200MΩ/2000MΩ AC Voltage Range 0 - 600V AC Output Voltage on Open Circuit Rated Test Voltage +20%, -0% General Specifications

Nominal Current 1mA DC min Power Source R6P (AA) (1.5V) x 8 Output Short Circuit Current 1.5mA DC approx. Dimensions (mm) 185 (L) 167 (W) 89 (D) Continuity Test Ranges Weight 990g approx. Measuring Ranges 20MΩ/200MΩ/2000MΩ

Stock no. Price per OM S$ S$ S$

627-8760 unit 1+ 1000·00

Stock no. Price per OM S$ S$ S$

466-6014 unit 1+ 540·00

Wiring connection check LEDs: Immediate indication if

wiring of circuit under test is correct

Overheat Protection:Rapid detection of overheating of

internal circuitry, display of warning signal to user and

automatic halting of measurement

Supply Voltage Indication: Can display supply voltage

value in loop impedance mode

Low Current Loop Impedance Test: Short duration low

test current will prevent tripping of many passive RCDs

Phase Angle Selection: Selection of test current from +ve

or -ve half cycle of waveform can prevent tripping of

polarized type RCDs

Loop Impedance Ranges (Z reading) 20/200/2000Ω 1000ms: x1/2, x1, DC Max test current on Loop ranges 3A (20Ω) / 15mA (200

and 2000Ω) 200ms: x5, DC (500mA), & x1

(1000mA) PSC / Earth Fault Current Ranges 200/2000A/20kA RCD Ramp Test From 20% to 110% of

IΔn (AC type) RCD Test AC Type (Standard and Selective) Contact Voltage Reading (RCD) 100.0V x1/2: 10, 30, 100, 300, 500,

1000mA Working Voltage for Loop Tests 20Ω: 230V+10%-15%

x1: 10, 30, 100, 300, 500,1000mA

200/2000Ω:230V+10%-15% and400V+10%-15%

x5: 10, 30, 100mA Working Voltage for RCD Tests 230V+10%-15% Auto Ramp: 10, 30, 100, 300, 500mAVoltage Tests 100 ∼ 260V RCD Test A Type (Standard andSelective)

10, 30, 100, 300, 500mA (LOOP 200/2000Ω,PSC 200A:100 ∼ 440V)

RCD Test Currents multipliers x1/2, x1, x5 Memory 300 memory locations (max 1000mA type AC)Dimensions 186(L) x 167(W) x

89(D)mm (max 500mA type A) Weight 980g

RCD Test Time Duration

Standards: IEC61010-1 CAT.III 300V Pollution Degree

Stock no. Price per OM S$ S$ S$

255-049 unit 1+ 470·00

2, IEC61010-2-031, IEC61557

Continuity Testing Output Voltage on Open Circuit 570V DC±6% Measuring Ranges (0-19.99) and 10.0-

199.9Ω (2 auto ranges) Rated Current >1mA(as per IEC364)

Open Circuit Voltage > 4V(as per IEC364) Accuracy ±(3% + 3dgt) Short Circuit Current > 200mA DC(as per

IEC364) RCD Testing

Accuracy ±(3% + 3dgt) Rated Voltage 230V AC +10%-15%(50Hz)

Loop Impedance Testing Trip Current Settings RCD × 1/2: 5, 15, 50, 150,250mARCD × 1: 10, 30, 100, 300,500mA

Rated Voltage 230V AC +10%-15%(50Hz)

Trip Current Duration RCD × 1/2 × 1: 2000ms

Voltage Measuring Range 100-250V AC (50Hz) Fast Trip 150mA Impedance Range Nominal TestCurrent

20/2000Ω 25A(20Ωrange) 15mA(2000Ω range)

Accuracy Trip current ±3% of testcurrent at 230V. Trip time ±(3% + 3dgt)

Test Period 1/2 cycle (10ms) General

Accuracy 20Ω range : ±(3% +8dgt) 2000Ω range :±(3% + 8dgt)

Withstand Voltage 4000V AC for 1 minute

Insulation Testing Power Source R6P(AA)(1.5V) × 8 Measuring Ranges 0-19.99 and 10.0-

199.9MΩ (2 auto ranges)Dimensions 175(L) × 115(W) × 86(D)

mm Test Voltage 500V DC Weight 780g approx.

Manu. Part No. Stock no. Price per OM S$ S$ S$

6010A 627-8776 unit 1+ 460·00

2244

www.nguyenxuong.com

Page 10: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Sanwa Insulation Testers

Chauvin Arnoux Electrical Installation TestEquipment

Combination Testers

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Visit our website for additional price information and exciting promotions

DM 1528S Analogue InsulationResistance Tester

DM 508S/DM 1008S AnalogueInsulation Resistance Tester

DG7 Mini Digital Insulation Tester

CA6521, CA6523 andCA6525 Insulation Testers

Instaltest Combo MI-3125 Seaward Electronic

Technical Specification - General

Display 4200-count LCD with LogBargraph

Operatingtemperature

0 to 40°C

Measurementnethod

Average value sensing Operating humidity 0 to 90% non-condensing

Sampling rate 2 readings per second Power source 6 x AA cell, Alkaline forMG1000

Range selection Auto only; Up at >4200, Downat <380

Size and Weight 170 x 142 x 57 mm, 600 g

A compact light weight easy to use insulation resistance tester. Inner

magnetic field taut-band type meter gives a reliable stable needle

indication. The Auto-discharge function is also featured.

Compact light weight easy to use insulation resistance testers. Inner

magnetic field taut-band type meter gives a reliable stable needle

indication. The Auto discharge function is also featured. Digital LCD with simulated analogue arc bargraph

200mA continuity test capability

Super small pocket size & compact insulation tester

Various test voltages available

Wide measurement range

Data hold functionality

Auto power save (30min.) to conserve battery power

Sampling rate : 2 times / sec. for numeral display, 20

times for bargraph

Technical Specification - Measuring Ranges

Insulation resistance MG500 MG1000

Measuring ranges 5: 400.0 kΩ to 4000 MΩ 4: 4.000 MΩ to 4000 MΩ

Test voltages 125-250-500V 250-500-1000V

Bargraph centre scale 10-100-1000 MΩ 10-100-1000 MΩ

Accuracy

1st effective meas range ±(3% rdg +4 digits) ±(3% rdg +4 digits)

2nd effective meas range ±(5% rdg +5 digits) ±(5% rdg +5 digits)

Resistance/Continuity (MG500 & MG1000)

Range Resolution Accuracy

4000 Ω (+ buzzer) 1 Ω ±(3% rdg +3 digits)

40.00 Ω 0.01 Ω ±(3% rdg +10 digits)

Voltage AC/DC (MG500 & MG1000)

600 Vac/dc 1 V ±(3% rdg +2 digits)

Input resistance: 9 MΩ Overload: 780 Vrms

Continuity buzzer

Lead resistance compensation (Not CA6521)

Auto power down to save batteries

Battery life indication

Programmable thresholds with buzzer alarm

Timer measurements over long periods (CA6525 only)

IP54 ingress protection

3 range tester for maximum versatility

MΩ measuring switch allows one-shot and continuous

measurements

dc voltages up to 60V can be measured

ac voltages up to 600V can be measured

Handy neck strap for hands free operation

IEC 1010-1 CATIII 600V

JIS C 1302-1994

Description Stock no. Price per OM S$ S$ S$

MG500 543-302 unit 1+ 450·00

MG1000 543-308 unit 1+ 495·00

The 3-in-1 multi-function tester, installation

tester and pass/fail tester

MΩ measuring switch allows one-shot and continuous

measurements

dc voltages up to 60V can be measured

ac voltages up to 600V can be measured

Handy neck strap for hands free operation

IEC 1010-1 CATIII 600V

JIS C 1302-1994

BestAccuracy

± (2% + 0 to 4digit)

Battery Silver OxideCell SR44 x 2

Resolution 0.001 MΩ Size 117(H) x 76(W)x 18(D) mm

Display 4000 Weight 125g

MG Series Testers

Supplied with: 6 x LR6 batteries, "Hands-free" shoulder bag and test leads.

Function Range 250V Insulation Test 0.05 to 500MΩ

1000V Insulation Test 1 to 2000MΩ ac Voltage 0 to 600V500V Insulation Test 0.5 to 1000MΩ dc Voltage 0 to 60V

Function Range ac Voltage 0 to 600V500V Insulation Test DM 508S 0.5 to 1000MΩ dc Voltage 0 to 60V500V Insulation Test DM 5 to 2000MΩ Battery life DM 508S 5.5 hours1008S Battery life DM 1008S 4 hours

Stock no. Price per OM S$ S$ S$

627-8726 unit 1+ 305·00

Replaces multimeter, insulation tester, RCD tester, loop

impedance tester and phase sequence tester

Installation verification tests to AS/NZS3017 covering earth

continuity, insulation resistance, polarity, correct connections,

fault loop impedance and RCD tests

Tests sockets in seconds with single push button and without

trailing leads

Preset and user defined Pass/Fail limits with on-screen tick/cross

plus red/green LED indicators

Model Number CA 6521 CA 6525

Insulation

Voltage (V) 250, 500 250, 500, 1000 Range (Ω) 50k to 2000k 50k to 2000k Accuracy ±(3% + 5digts) ±(3% + 5digts) Continuity

Range (Ω) 0 to 19.99 0 to 19.99 Resolution (Ω) 0.01 0.01 Accuracy ±(3% + 5digts) ±(3% + 5digts)

Manu. Part No. Stock no. Price per OM S$ S$ S$

DM508S 384-1309 unit 1+ 245·00

DM1008S 384-1315 unit 1+ 275·00

Supplied with: Test leads, test probes, alligator clips and resistor

box

Insulation Resistance Testers

Stock no. Price per OM S$ S$ S$

384-1292 unit 1+ 320·00

Loop Impedance Ranges 20/200/2000Ω (20/200Ω D-LOK) PSC Ranges 200A (2.3A 40ms) Loop Impedance Accuracy ±2% rdg ±4 dgt 2000A (25A 20ms) D-LOK AC Test Current 20Ω 25A 20kA (25A 20ms) D-LOK

200Ω 2.3A PSC Ranges Accuracy ±2 % rdg ±4dgt 2000Ω 15mA Voltage 110V-260V ±2% rdg ±4 dgt

AC Test Period 20Ω (20ms) Operating Voltage 230V +10% -15% (195 - 253V) 50Hz 200Ω (40ms) Dimensions 185(L) × 167(W) × 89(D) mm 2000Ω (280ms) Weight 960g

Warning of live (>30V) circuit detection via buzzer and red warning LED

Buzzer plus large "flash" symbol on LCD alert user when test voltage is

generated

Operation of highest test voltage is interlocked to prevent inadvertant

or accidental operation

Large log scaled bargraph allows measured value to be checked with

the same ease-of-use as an analogue tester.

Automatic data hold for last measured value

Backlight allows use in poorly lit conditions

Durable and tough body, with easy-to-hold "portrait"shape

Case is fitted with carrying strap and non-slip side grips for safe and

secure handling

Display 128 x 64 dot matrix LCD with backlight

Power source 6 x 1.5V batteries

Enclosure rating IP40

Dimensions 230 x 140 x 80mm

Overvoltage Category 600V CAT III, 300V CAT IV

Weight 1000g

Loop Impedance Test Type 3 wire Automatic RCD Test Yes Download Yes Non Tripping Yes

Stock no. Price per OM S$ S$ S$

255-039 unit 1+ 520·00

Standards: IEC61010-1 Cat III 600V

Stock no. Price per OM S$ S$ S$

712-6023a unit 1199·00

Supplied with: Test lead set & Instructions

2245

www.nguyenxuong.com

Page 11: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Earth Testing

Fluke Insulation and Continuity Testers

Fluke Installation Testers

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple a New product to range

Fluke 1625 GEO Earth Ground Tester Kit

Fluke 1507 / 1503 Insulation Testers

Fluke 1650 Series

A comprehensive earth tester capable of conventional 3 and 4

pole measurement of the resistance of earth installations, and

ground resistivity. It offers many advanced features, including

&#146;selective’ earth testing and ’stake-less’ earth testing.The

stake-less method is able to measure the resistance of individual

ground connections in multi grounded systems without the use

of ground stakes; 2 clamps are clamped around the earth rod so

leaving the bonded earth ground system intact during testing.

Using this method, earth resistance tests can be conducted

where there is on access to soil.

3- and 4-pole earth ground measurement

4-Pole soil resistivity testing

2-pole resistance measurement AC

2- and 4-pole resistance measurement DC

Insulation test range: (1507): 0.01MΩ to 10GΩ, (1503): 0.1MΩ to 2000MΩ

Insulation test voltages: (1507) 50V, 100V, 250V, 500V, 1000V; (1503) 500V,

1000V

Automatic calculation of Polarization Index and Dielectric Absorption Ratio

(1507 only)

Compare (pass/fail) function (1507 only)

Remote test probe

Live circuit detection prevents insulation test if >30V is present

Auto-discharge of capacitive voltage

Voltage range 0.1 to 600Vac/dc

Continuity 200mA

Resistance 0.01 to 20kΩ

Multifunction installation testers to verify the safety of

electrical installations in industrial, commercial and

domestic applications

Meet the requirements of IEC 60364, HD 384 and BS 7671

17th Edition wiring regulations

Large illuminated display with exceptionally wide viewing

angle

Rugged: withstand a one meter drop for demanding field

use

Selective testing with no disconnection of ground conductor (using one clamp)

Stake-less testing with no disconnection of ground conductor and no ground stakes for quick

ground loop testing using 2 clamps

Resistance measurement without current or voltage spikes for rapid testing of pole mounted

transformers.

Earth impedance measurement at 55 Hz

Automatic frequency control (94, 105, 111, 128 Hz) selects a measuring frequency to minimise the

effect of existing interference

Selectable test voltage20/48V enables safe testing where livestock may be present

IP56 splash-proof case

Programmable GO / NO-GO limits, settings

Continuity with buzzer

All inputs are protected to EN 61010-1, CAT III 500V

Battery indicator, and battery test function

Weight 1.2kg

Supplied with: Remote probe, test leads, test probes, alligator clips, holster, user

documentation.

Supplied with: 2 test leads, 4 earth ground stakes, 3 cable reels with wire (2 x 25m, 1 x 50m), clamp

set for selective / stake-less (one inducing, one sensing), batteries, manual, carrying case.

AC/DC Voltage Accuracy Short circuit current 1mA nominal Range accuracy 600.0V General Specifications

Resolution accuracy 0.1V Max. voltage applied to any terminal 600Vac rms ordc

50Hz to 400Hz +/- (% of Rdg + Digits)accuracy

+/-(2% + 3) Operating temperature -20 °C → +55°C

Overload protection 600V rms or dc Dimensions H203 x W50 xD100mm

Earth Bond Resistance Measurement Weight 550g Range accuracy +/-(1.5% + 3) Overload protection 2V rms or dc Height (mm) 203 Insulation Specifications Width (mm) 50 Test voltages 1507; 50V, 100V,

250V, 500V,1000V1503: 500V,1000V

Depth (mm) 100

Test voltage accuracy +20%, -0% Weight 0.5 kg

Support Accessories:

Display 4 digit 3000 count LCD Accuracy ±7% of range +2 digits 3 & 4- pole measuringrange

0.001Ω to 300kΩ Operating errors ±10% of range +5 digits

Accuracy ±2% of range +2 digits Test current 250mA a.c. short circuit Operating errors ±5% of range +5 digits Test voltage 20V / 48V a.c. Selective rmeasuringranges

0.001Ω to 30kΩ Battery life Typical 3000 measurements(RE+RH ≤ 1kΩ)Typical 6000 measurements(RE+RH ≤ 10kΩ)

Accuracy ±7% of range +2 digits Dimensions (W x H x D) 250 x 133 x 187mm Operating errors ±10% of range +5 digits Weight 1.1 kg including batteries

5.5 kg including accessories andbatteries in carrying case

Stake-less measuringrange

0.001Ω to 30kΩ Working temp. range -10 °C → +50 °C

TP165X remote probe Slim line remote probe with built-in test button to facilitate one-handed

measurements on Fluke 1650 & 1650B series installation testers see 468-0616

TL165X fused test lead set see 468-1063

Earth Spike Test kit: For earth resistance testing on the Fluke 1653 & 1653B using the 3 wire

connection method and auxiliary earth spikes.

Contains Auxiliary earth probes, test connection leads and crocodile clips, purpose-made carry

case . See 468-0600

FVF-SC2 FlukeView� documenting software: for documenting, storage and analysis of

measurements, from the Fluke 1653B and 1654B. Allows editing of an existing form or creation of a

new form to customize the report to individual needs

Contains software on CD-ROM and USB/ IR interface cable See 385-0599

Lead Compensation No YES Resistance

Range (Ω) No 0 to 399.9k Resolution (Ω) No 0.1/1/10/100 Accuracy No ±(3% +2digts) Voltage

Range (V) 0 - 600 ac/dc 0 - 600 ac/dc Resolution 0.1/1V 0.1/1V Accuracy ±(3% + 1digt) ±(3% + 1digt) Alarm No YES Timer No 0 to 15 mins Size (WxHxD) & Weight 108 x 211 x 60mm, 835g 108 x 211 x 60mm, 835g Safety IEC 61010-1 CAT III 600V IEC 61010-1 CAT III 600V

Description Stock no. Price per OM S$ S$ S$

1503 518-5998S unit 1+ 737·00

1507 518-6008S unit 1+ 858·00

Description Stock no. Price per OM S$ S$ S$

CA6521 346-7355S unit 1+ 680·00

CA6525 346-7377S unit 1+ 870·00

Contact RS for calibration requirements

Stock no. Price per OM S$ S$ S$

645-1820 unit 1+ 6133·00

Note: 6AA Alkaline are originally supplied, 1.2V NiMh are also suitable; all stored data will be lost if

batteries are not replaced within approximately 1 minute for model 1653B and 1654B

RS is currently unable to supply replacement fuses for these products.

Supplied with: (All models): detachable leads (TP165X & TL165X), 6 AA cell batteries, a durable

hard carrying case, padded carrying strap, mains test cord, quick reference guide.

1651B 1652C 1653B 1654B

Voltage, frequency � � � �

Polarity � � � �

Insulation resistance testvoltages

250, 500,1000V

250, 500,1000V

50, 100, 250, 500,1000V

50, 100, 250, 500,1000V

Continuity & Resistance � � � �

Fast, high current loop test � � �

High current loop test with 1 mΩ resolution �

Non trip loop impedance test � � � �

RCD tripping time � � � �

RCD tripping current level ramp test � � �

RCD auto test & ramp test � � �

Standard AC RCD tests (G & S-Type)

� � � �

Pulsating DC sensitive RCD tests (G & S-type) � � �

Earth resistance (RE) � �

Phase sequence indicator � �

Memory (500 measurements) � �

IR interface for data downloading � �

Remote Probe � � �

Description Stock no. Price per OM S$ S$ S$

Fluke 1651B 712-5954S unit 1+ 1536·00

Fluke 1652 Aus/NZ 482-1974 unit 1+ 2833·00

Fluke 1653 Aus/NZ 482-1952 unit 1+ 2550·00

Fluke 1653B 712-5951S unit 1+ 2574·00

Fluke 1654B 712-5960S unit 1+ 2789·00

Accessories

Description Stock no. Price

per

OM S$ S$ S$

FVF-SC2 Flukeviewsoftware

385-0599 unit 1+ 390·00

ES165X Earth Spike Kit 468-0600 1 kit 1+ 282·00

TP165X Remote Probe 468-0616 unit 1+ 127·00

TL165X Fused Lead Set 468-1063 unit 1+ 185·00

2246

www.nguyenxuong.com

Page 12: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

New products available online every week

DLR010HD Heavy Duty 10A LowResistance Ohmmeter

Digital Low Resistance Ohmmeter

DET4TCR/2 4 Pole Earth Tester

Earth Testing Field Kit

DET4TC 4 Pole Earth Tester

This kit provides all the necessary equipment to enable

earth testing to be carried out in conjunction with a 3 or 4

pole earth tester

4 pole earth tester with rechargeable batteries for measuring

soil resistivity and resistance of earth rods and associated

installations. Supplied in a hard carry case together with

auxiliary stakes and cables.

4 pole earth tester for measuring soil resistivity and resistance

of earth rods and associated installations. Supplied in a hard

carry case together with auxiliary stakes and cables.,An ICLAMP

selective clamp is available separately, and when used with the

DET4TC allows the testing of an earth rod without the need for

disconnection from the system.,A VCLAMP is also available

separately, which when used in conjunction with ICLAMP

allows stakeless measurements to be made in situations where

driving auxiliary stakes is not practical.

Large backlit LCD display, controlled by 2-axis paddle for ease of use.

Results can then be stored together with any relevant notes, for later

download to a PC.

Resistance range 0.01 to 20,000 ohms auto ranging

Choice of 2, 3 or 4 terminal measurements

Simple one button operation

Superior noise rejection to 40V pk-pk

Results in less than 3 seconds

Lightweight, easily portable and easy to use

4-wire measurement to null out lead resistance

Auto mode. Connection of handspikes supplied automatically starts

test without the need to press test button

Auto current reversal cancels out standing EMFs

User selectable high and low limits

Memory for up to 700 sets of results complete with notes of up to 200

characters

Keypad for extra data entry

Fuse protected to 600V

NiMH battery reduces weight

Contents:

Heavy duty low resistance ohmmeter combining

rugged construction with accuracy and ease of

use. It features an internal rechargeable battery

Resistance range 0.01 to 20k ohms auto ranging

Choice of 2, 3 or 4 terminal measurements

Simple one button operation

Superior noise rejection to 40V pk-pk

Measures earth voltage 0 – 100V

Automatic P spike and C spike check

Clamp input for no-disconnect testing (required ICLAMP)

Clamp inputs for stakeless testing (required ICLAMP and

Tool bag

One 2.5lb (1.1kg) hammer

Four galvanised steel spikes

30m and 50m lengths of cable on a cable-winder

3m leads complete with connectors and clips

Measures earth voltage 0 – 100V

Automatic P spike and C spike check

Clamp input for no-disconnect testing (required ICLAMP)

Clamp inputs for stakeless testing (required ICLAMP and VCLAMP)

Earth current range (requires ICLAMP)

and can also operate from a mains supply, even if the battery is

completely flat

250mW power limit (with optional override) to avoid heating the test sample

VCLAMP)

Earth current range (requires ICLAMP)

Stock no. Price per OM S$ S$ S$

204-612 unit 1+ 580·00

Supplied with: 2 x spikes, mains charger, car charger and NiMH battery.

Standards: EN61010-1 CAT IV 100V

Standards: EN61010-1 CAT IV 100V

2 high power ( up to 25W) ranges ideal for inductive applications,

and where heating a potential weakness is desirable

7 low power output ranges limited to 0.25W to avoid heating the

test piece and to extend battery life.

Rechargeable battery or line power supply, continuous operation,

even with dead battery

10 A for 60 seconds, less time waiting to cool, great for charging

inductance

High input protection to 600 V, inadvertent connection to line or

UPS voltage will not blow a fuse

Heavy duty case: IP 65 lid closed, IP54 operational (battery operation only)

Large backlit LCD is clear and easy to read in all lighting conditions.

Rotary switch selects one of five test modes, including auto start on connection, giving ease of use

1·9999Ω 100μΩ ±0·2%±0·2mΩ 20mV 10mA

19·999Ω 1mΩ ±0·2%±2mΩ 20mV 1mA

199·99Ω 10mΩ ±0·2%±20mΩ 20mV 100μA

1999·9Ω 100mΩ ±0·2%±0·2Ω 200mV 100μA

Measurement modes Manual, Auto Continuous, High Power, Unidirectional

Test current accuracy ±10%

Output current stability >10ppm per sec @ 10mA; >100ppm per second @ higher currents

Voltmeter input impedance > 200kΩ

Hum rejection Less than 1% +20 digts additional error with 100mV rms 50/60Hz onpotential leads. If exceeded, a warning lamp will illuminate.

Battery capacity 7Ah NiMH rechargeable battery

Battery life Typically 1000 x 10A tests

Recharging External 115/230Hz charger or 12V car battery

Standard charging rate 4 hours

Quick charging rate 2.5 hours to 90% capacity @ 20°C

Operating temperature +5 → +45 °C full specification; -10 → +50 °C reduced accuracy

Error v. temperature <0·01% per°C over range 5 to 40°C

Standard charge 0 → +45 °C

Fast charge +10 → +45 °C

Safety EN61010-1 600V Category III, (with DH6 handspike set)

Size (HxWxD) & Weight 220 x 100 x 237mm, 2.6kg

Full scale Resolution Accuracy Volts (full scale) Test Current

1·9999mΩ 0·1μΩ ±0·2%±0·2μΩ 20mV 10A

19·999mΩ 1μΩ ±0·2%±2μΩ 20mV 1A

199·99mΩ 10μΩ ±0·2%±20μΩ 20mV 100mA

Supplied with: 4 earth test stakes, 4 connection leads, 8 x AA NiMH rechargeable batteries, hard carry

case, mains charger, quick start guides, user guide on CD

Supplied with: 4 earth test stakes, 4 connection leads, 8 x AA alkaline batteries, hard carry case, quick

start guides, user guide on CD

Stock no. Price per OM S$ S$ S$

410-0110S unit 1+ 8070·00

Resistance range 0.01 to 20kΩ Test frequency Hz 94.105.111 Accuracy 2% ± 3 digits Earth current range with ICLAMP 0.5mA to 19.9A Ingress protection IP54 Display LCD with back light Output ±25V or ±50V Operating temp. -15 → +55 °C

Resistance range: 0.01 to 20,000Ω Earth current range with ICLAMP 0.5mA to 19.9A Accuracy: 2% ± 3 digits Display: LCD with back light Ingress protection: IP54 Operating temp: -15 → +55 °C Output ±25V or ±50V at 128Hz

Support accessories:

Description Stock no. Price per OM S$ S$ S$

DET4 TCR2-RS 489-674S unit 1+ 2000·00

ICLAMP 514-4672 unit 1+ 460·00

DH5 straight duplex handspike set with 2.5m long leads. See stock no. 666-7371

Description Stock no. Price per OM S$ S$ S$

DET4 TC-RS 489-664S unit 1+ 1480·00

VCLAMP 104-767 unit 1+ 415·00

ICLAMP 514-4672 unit 1+ 460·00

Supplied with: DH4 duplex handspikes with 1.2m lead length, test lead pouch (lid mounted) user

guide on CD ,6V 7Ah sealed lead acid battery (fitted)

Test Current Resistance Range Resolution Accuracy * Full scale voltage Max. power output

0.1 mA 0 → 2500.0 Ω 100 mΩ ±0.2% ±200 mΩ 25 mV 2.5 μW

0.1 mA 0 → 250.00 Ω 10 mΩ ±0.2% ±20 mΩ 25 mV 2.5 μW

1 mA 0 → 25.000 Ω 1 mΩ ±0.2% ±2 mΩ 25 mV 25 μW

10 mA 0 → 2500.0 mΩ 100 μΩ ±0.2% ±200 μΩ 25mV 250 μW

100 mA 0 → 250.00 mΩ 10 μΩ ±0.2% ±20 μΩ 25 mV 2.5 mW

1 A 0 → 25.000 mΩ 1 μΩ ±0.2% ±2 μΩ 25 mV 25 mW

10 A 0 → 2500.0 μΩ 0.1 μΩ ±0.2% ±0.2 μΩ 25 mV 0.25 W

1 A 0 → 2500.0 mΩ 100 μΩ ±0.2% ±200 μΩ 2.5 V 2.5 W

10 A 0 → 250.00 mΩ 10 μΩ ±0.2% ±20 μΩ 2.5 V 25 W

* The accuracy stated assumes forward and reverse measurements.Inductive mode or unidirectional mode will introduce an undefined error if an external EMF is present

Measurementmodes

Normal, Automatic, Continuous, Inductive, Unidirectional

TemperatureCoefficient

< 0.001% per °C, from 5 °C → 40 °C

Test currentAccuracy

±10%

Voltmeter inputimpedance

>200 kΩ

Noise rejection: <1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads.Warning will show if hum or noiseexceeds this level.

Battery capacity 6V 7AH sealed lead acid

Battery Life 1000 Auto (3 sec) tests

Charging time 8 hours

OperatingTemperature

+5 °C → +45 °C full specification, -10 °C → +50 °C reduced accuracy

Line voltage inputrange

90 → 264 V rms, 9 → 17 VA, 50/60 Hz

Dimensions &Weight:

315 x 285 x 181mm : 6.7kg

Description Stock no. Price per OM S$ S$ S$

DLR010HD 712-5768Sa unit 1+ 6260·00

2247

www.nguyenxuong.com

Page 13: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple

4105A Compact Digital EarthTester

4102A High PerformanceAnalogue Earth Tester

CA 6415 Ground Tester

Fluke 1630 Earth Ground Clamp Meter

CA6250 10A Low ResistanceMicro-ohmmeter

DET14C & DET24C Earth TestClamp

Portable 10A Micro-ohmeter for testing the quality of

mechanically bonded metalwork, contacts and switches,

Dust and Drip Proof

Allows quick checking of earth loops without

disconnecting the earth cable under test

Push button controls for single handed operation

Ground resistance range : 0.050 Ω to 1500 Ω

True RMS Ground leakage current range : 0.2 mA to 35 A

Auto ranging & HOLD function

4 digit plus 6 digit backlit LCD display

High and low resistance alarms

256 test results storage & recall

Real time date & time stamping of results

Oval clamp for easy access to earth cables & earth straps

37mm dia conductor & 50mm earth strap capacity

Low maintenance flat jaw interface

EN61010 Safety rating CATIV 600V

Extended battery life

Dust and drip proof (desgined to IEC60529 IP54)

An earth ground clamp meter to simplify ground loop testing also known as

’stakeless’ earth ground testing with no need for placing earth stakes and

disconnecting the earth system from the electrical installation.The Fluke 1630 is

ideally suited for the following applications:,Ground loop checks on any earthing

system;,Continuity tests on earth bonding circuits and connections;,Inspection of

lightning protection systems.

Precision measurement and test leads for simplified two wire

measuring system supplied as standard accessories

Automatic warning when resistance of auxillary earth spikes is in

excess of tolerance

Small, lightweight and shock resistant

A wide ground loop resistance range, from 0.025Ω to 1500Ω, to satisfy all

requirements

33mm jaw size for tests on ground conductors and/or equipotential bus bars

Measurement of ground leakage current, from 0.2mA to 1000mA, without needing

to disconnect - ideal for system troubleshooting

Wide true RMS ac current measurement range from 0.2A to 30A allows one

instrument for multiple applications

User-defined HI/LO alarm limits, for rapid measurement evaluation

Display-HOLD function to freeze measurements

resistance of cables and heating of motors and transformers.

DET24C Additional Features

0 to 1200Ω measuring range

Measurement of leakage current from 1 to 30mA

Earth “Noise” indicator to maintain highest accuracy

Large 32mm clamp diameter

Sealed flat face jaws for ease of cleaning and reliability

User suitable alarm thresholds

99 measurement capacity

Visual indicators for battery life, Jaws closed and Display

Hold

Precision measurement and two wire measuring system supplied as

accessories

Capable of measuring earth voltage

Recording function for automatic storage of measured values, which can be recalled later on the

LCD display

Automatic self calibration ensures correct measurement every time

Complies with EN61010-1 CAT III 300V

Overload protection: 200 A

Standards: IEC 61010-1, CAT III 300V Pollution Degree 2, IEC61557

Supplied with: Alkaline battery and carrying case.

Large backlit LCD display

Broad measurement range 1μΩ to 2,500Ω

Temperature compensation of readings to allow for temperature

variations

4 wire measurement with automatic compensation for spurious

voltages

Automatic detection of the presence of external AC or DC voltages

on the terminals to disable measurements where accuracy cannot be

guaranteed

3 measurement modes:

Inductive mode for measurements on inductive components

(transformers, motors, etc.)

Non-inductive mode for measurements on resistances, with a time

≥ 8 hours battery life (continuous operation)

IrDA to USB interface for download

Standards: IEC 61010-1, CAT III 300V Pollution Degree 2, IEC61557

Resistance 0.1Ω to 1.2kΩ in 7 ranges Alarm Adjustable thresholds from 1 to 199ΩResolution (Ω) 0.01 at 0.1 to1Ω Safety Complies with EN61010-2-032 1500V,

cat III, pollution level 2 Frequency of use(Hz)

2400 Power supply 1 x 9V alkaline or NiCD battery

Current 1 to 300mA; 0.3 to 3.00A; 3 to 30A Size (HxWxD) &Weight

55 x 100 x 235mm, 1kg

Resolution (mA) 1mA @ 3.0mA; 10mA @ 3 to 30A

2000 test results storage

PowerDB LiteTM software

constant of a few ms (contacts, metallization, etc.)

Non-inductive mode with automatic triggering for measurements on resistances with no time

constant

Programmable audible alarm limit

Memory storage of 1,500 measurements

2 wire PT100 temperature probe input

RS232 interface for connection to a PC or printer

Rechargeable NiMH batteries with integral charger

IP64 case (closed); IP53 (open)

Complies with EN61010-1 CAT III, 50V

Supplied with: 9V PP3 battery, carry case, resistance test loop & instructions.

Measurement Ranges

Earth Resistance 20Ω/200Ω/2000ΩEarth Voltage

(50-60Hz) 0-200V AC Accuracy

Earth Resistance equals ±2% rdg ±0.1Ω (20Ω range) equals ±2% rdg ±3 digits (200-2000Ω)

Earth Voltage equals ±1% rdg ±4 digits Power Source R6P (AA) (1.5) x 6 Dimensions (mm) 105 (L) 158 (W) 70 (D) Weight 550g approx.

Measurement Ranges Earth Voltage equals ± 3% of fullscale

Earth Resistance 12Ω/120Ω/1200Ω Power Source R6P (AA) (1.5V) x 6 Earth Voltage (50-60Hz)

0-30V AC Dimensions (mm) 105 (L) 158 (W) 70(D)

Accuracy Weight 600g approx. Earth Resistance equals ± 3% of full

scale

Stock no. Price per OM S$ S$ S$

466-6058 unit 1+ 375·00

Stock no. Price per OM S$ S$ S$

466-6036 unit 1+ 340·00

Stock no. Price per OM S$ S$ S$

375-2574 unit 1+ 2190·00

Supplied with: Carry case, NiMH batteries (fitted), 2m test lead set with Kelvin clips; mains power

lead and instruction manual.

Contact RS for calibration requirements

Supplied with: (DET14C & DET24C):Carry case carry strap , User guide on CD, calibration check

accessory, 4 x AA alkaline batteries.

(DET24C only): USB IrDA dongle, USB lead & PowerDB lite software

Range Resolution Accuracy Test current

5.0000 mΩ 0.1 μΩ 0.15 % + 1.0 μΩ 10 A

25.000 mΩ 1 μΩ 0.05 % + 3 μΩ 10 A

250.00 mΩ 10 μΩ 0.05 % + 30 μΩ 10 A

2500.0 mΩ 0.1 mΩ 0.05 % + 0.3 mΩ 1 A

25.000 Ω 1 mΩ 0.05 % + 3 mΩ 100 mA

250.00 Ω 10 mΩ 0.05 % + 30 mΩ 10 mA

2500.0 Ω 100 mΩ 0.5 % + 300 mΩ 1 mA

Power 5 off D cell (8.5Ah) NiMH rechargeable batteries ;typical life 5000 Hours ( 10A test)

Charger supply 90 to 264V @ 45 to 420Hz

Dimensions 270 x 250 x 180 mm

Weight 4kg

Range Resolution

Resistance 0.025 to 1500 Ω 0.002 Ω to 20 Ω

Current 0.2 to 35A 0.01A

Leakage current 0.3 to 1000 mA 0.001mA to 1mA

Continuity Buzzer <40Ω approx

Dimensions & Weight 257 x 100 x 47mm: 640g

Battery 9V alkaline PP3 (supplied)

Battery life ≥8 hours (continuous operation)

Resistance Measurement 0.05Ω (±1.5% ± 0.05Ω) to 1500Ω (±35%) in 8 ranges

Current Measurement 0.200 mA (± 2.0% ± 0.05 mA) to 35.0 A (± 2.0% ± 0.1 A) in 6 ranges

Battery life 24 hours continuous @ 25Ω

Operating temperature -20 °C → +55 °C

Dimensions & Weight 248 x 114 x 49 mm, 960g

Stock no. Price per OM S$ S$ S$

712-5967S unit 1+ 2521·00

Stock no. Price per OM S$ S$ S$

236-571 unit 1+ 5380·00

Description Stock no. Price per OM S$ S$ S$

DET14C 705-9422S unit 1+ 1710·00

DET24C 705-9431S unit 1+ 1980·00

2248

www.nguyenxuong.com

Page 14: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

AC Current Clampmeters

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Many more leading brands from over 2,500 suppliers available online

ICM A5 Electrical Tester withNon Contact Voltage Detector

ICM A7D Electrical Tester

IEK 10 Digital Multimeter withCurrent Clamp

Fluke 365

4200 Earth Clamp Tester

Fluke T5-600 & T5-1000 Multi-function

Backlit LCD display with display HOLD

Detachable compact jaw head for easy access to tightly

packed wires

Compact design fits in the hand and can be used while

wearing personal protective equipment.

200 A ac (true rms) and dc current measurement with

fixed jaw

600 V ac (true rms) and dc voltage measurement

Resistance & continuity measurement

CAT.IV Clamp Meters can measure voltages and

currents in both very low and high power circuits

Multiple Earthing System allows earth resistance

2000 count large LCD display

Slim line electrical tester to check voltage, resistance, continuity and current. The

integral non contact ac voltage detector enables fast identification of the presence of

mains voltages. The open jaw current clamp enables safe, non intrusive measurement

of ac currents up to 200A.

Current, Voltage and Continuity/ResistanceTesters

300Aac non-intrusive current measuring

Voltage measurement to 600Vac/dc

Ohms ranges from 300Ω to 30MΩ

3200 count display (0.1mV resolution at 300.V)

65 segment analogue bar graph

Innovative open jaw technology

200A (ac) measurement capability

600V dc/ac voltage measurement

2000Ω resistance range

Continuity bleeper

Display HOLD function

Auto power off

4mm plug in lead set allows replacement or connection of fused test leads

Safety to EN61010-01 600V CAT III for industrial environments

from 0.05 to 1200Ω to be measured without the auxiliary earth spikes

Accurate true RMS readings of AC current including distorted waveform

from 1mA to 30A

Noise Check Function detects current, which occurs during earth

resistance measurements and display ""NOISE"" mark on the LCD

Memory function allows saves and displays up to 100 measurement data

Data hold / Buzzer / Back light / Over-range indication functions

Applications include power distribution, power utilities and maintenance

fields

Mains proof ohms ranges

Fast continuity beeper

Diode test capability

Data hold function to freeze display

600V protection in every range

Auto power off

2000 counts large LCD display

Open jaw technology – 16mm dia. conductor size

200A ac measurement capability

750V ac/ 1000Vdc measurement range

Integral non-contact AC voltage detector with visual & audible indication

20MΩ resistance range

Continuity and Diode Test

Display hold

Auto–power off

Conforms to EN61010-1 (safety rating) CAT IV 600V, CAT III 1000V

Automatically measures AC & DC volts

Displays resistance up to 1000Ω

Easy and accurate OpenJaw� current measurement

Continuity beeper

Compact design with probe storage

Detachable probe tips

Protected to 600V (T5-600) and 1000V (T5-1000) for use in

CAT III environments

Power from 2 x AA cell

Auto switch-off

Built in flashlight for illumination and identification of wires

CAT III 600V safety rating.

State of the art signal processing allows for use in noisy electrical environments while providing

stable readings

Contact RS for calibration requirements

Supplied with: PP3 9V alkaline battery, users instructions & test leads.

Supplied with: Instructions, test lead set and 9V PP3 battery.

Supplied with: Soft carry case, 2 AAA alkaline batteries & instructions

Supplied with: IDM17 probe multimeter with 2xAAA alkaline batteries fitted, ICA15 current adaptor,

test lead set, operator’s manual, soft carry case.

Note: Only for multiple earth point systems only; single earth can not be

measured

Standards: IEC 61010-1 : 2001 (CAT.IV 300V Pollution degree2)

DC Voltage Accuracy ± (1.0% rdg + 2d) AC Voltage Lowest Range Resolution 0.1V DC Voltage Lowest Range 200V Resistance Accuracy ± (1.0 % rdg + 2d) DC Voltage Highest Range 600V Resistance Lowest Range 200ΩDC Voltage Lowest Range Resolution 0.1V Resistance Highest Range 20MΩ

AC Voltage Accuracy (45 to 60 Hz) ± (1.5% rdg + 3d) Resistance Lowest Range Resolution 0.1ΩAC Voltage Lowest Range 200V Dimensions & weight 185mm x 50mm x

35mm; 170g AC Voltage Highest Range 750V

Note: Please contact RS for calibration requirements

Current range 0.1 to 300A Accuracy ±(1.7%+5d) at 40 to 500Hz Accuracy ± (1.9%+0.5A) at 50 to 60Hz Resistance ranges 300Ω to 30.0MΩ

Max. cable size 29mm diameter Accuracy from ±(1%+2d) to ±(3%+5d) d.c. voltage range 300mV to 600V Safety

specification Designed to meet IEC 61010-1,Installation Category III 300V

Accuracy ±(0.7%+2d) Size (HxWxD) &Weight

102 x 72 x 36mm, 150g

a.c. voltageranges

300mV to 600V

AC Voltage 600V AC Accuracy ± (3% + 3 digits) AC Accuracy ± (1.5% + 3 digits) Ohms 2000ΩDC Voltage 600V Ohms Accuracy ± (1% + 2 digits) DC Accuracy ± (1% + 2 digits) Continuity Beeper 25 Ω beep on/ >300 Ω beep off AC Current 200A Size (HxWxD) & Weight 84 x 175 x 31mm, 280g

Note: T5 accessory kit available containing TP220 test probes, AC285 alligator clips, C33 soft zippered

case

Stock no. Price per OM S$ S$ S$

697-3989 unit 1+ 145·50

Measurement Range Resolution Accuracy

AC & DC Current 200 A 0.1 A ± (2% + 5d )

AC & DC Voltage 600 V 0.1 V ± (2% + 5d )

Resistance 6000 Ω 0.1 Ω ± (1% + 5d )

Jaw capacity 17mm ∅

Stock no. Price per OM S$ S$ S$

697-4064S unit 1+ 158·00

Stock no. Price per OM S$ S$ S$

697-3991 unit 1+ 139·50

Supplied with: Hard carry case & batteries

T5-600 T5-1000

AC voltage 600V rms 1000V rms

AC voltage accuracy ± (1.5% +2 digits) ± (1.5% +2 digits)

DC voltage 600V 1000V

DC voltage accuracy ± (1% + 1 digit) ± (1% + 1 digit)

AC current 100A 100A

AC current accuracy ± (3% + 3 digits) ± (3% + 3 digits)

Ohms 1000 ohms 1000 ohms

Ohms accuracy ± (1% + 2 digits) ± (1% + 2 digits)

Input impedance V ac/dc 1Mohm >100pf 1Mohm >100pf

Ohms <2.6kOhm <2.6kOhm

Safety IEC1010 CAT III 600V IEC1010 CAT III 1000V

Battery life 400 hrs typical 400 hrs typical

Size (HxWxD) & Weight 31 x 51 x 203mm, 300g 31 x 51 x 203mm, 300g

Description Stock no. Price per OM S$ S$ S$

T5-600 291-9372S unit 1+ 173·00

T5-1000 292-1230S unit 1+ 234·00

AC Current 100mA - 30A Earth Resistance (Autorange)

200 - 1200Ω

Operating System Earth resistance function : Constant voltage injection, Current detection, (Frequency : Approx.2400Hz) Dual Integration AC current function : Successive Approximation

Response Time Approx.7 seconds (Earth resistance), Approx.2 seconds (AC current) Sample Rate Approx. 1 times per second Current Consumption Approx. 50mA (max. 100mA) Withstand Voltage AC5320Vrms / 5 seconds, Between the Transformer jaws fitted parts and Case enclosure

(except for jaws) Dimensions 246(L) × 120(W) × 54(D)mm Weight 780g

Type Clampmeter Maximum Jaw Capacity ∅ 17 mmMaximum Current 200 A Maximum dc Voltage 600 VMaximum Voltage 600 V

Accessories

Stock no. Price per OM S$ S$ S$

255-033 unit 1+ 1130·00

Description Stock no. Price per OM S$ S$ S$

Fluke 365 705-1941S unit 1+ 431·00

Description Stock no. Price per OM S$ S$ S$

AC285 Large Alligator Clips 451-1431 unit 1+ 36·40

Holster T5-600/T5-1000 292-1246 unit 1+ 49·90

2249

www.nguyenxuong.com

Page 15: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple

ICM20 Digital Current Clamp

Multimeter Test Leads

ICM3090 Digital Clamp Meters

ICM33 II and ICM33R II DigitalClamp Meters

Fluke 333, 334 and 335

www.rssingapore.com

ICM 134 HVAC CurrentClampmeter

ICM A6 Automatic ElectricalTester, 600A

AC current clamp designed for safe, non-intrusive AC current

Replacement test leads to suit ISO–TECH and most other

digital multimeters. Fitted with right-angled 4mm shrouded

plugs and supplied with probe tip insulators to prevent

accidental short circuits and a pair of crocodile clips.,Probes

designed to meet BS EN 61010-1 (safety standard) 1000V Cat

III.,Current rating 10A.

Two clamp multimeters able to measure ac current up to 600A, ICM33R II has true rms

reading in AC current and AC voltage measurement.

Fully automatic intelligent tester that selects the measuring function dependant on

input terminal and current clamp conditions. No range of function selection is

necessary by the user. The priority is AC voltage, DC voltage, resistance then AC

current.

Three clamp meters designed to measure AC current, AC/DC voltage and

resistance.

A clamp multimeter designed to measure AC currents up to

Featuring current clamp, multimeter and thermometer functions the ICM134 is ideally

suited to HVAC and electrical maintenance applications up to 600A ac.

3 1/2 2000 count LCD

600V ac voltage measurement

2000Ω resistance range

Continuity beeper for <50Ω

Display hold

600V circuit protection

34 mm conductor jaw capacity

Powered by 1x alkaline PP3 battery (supplied)

Safety to EN 61010-1 CAT III 600V

Rugged construction with fire retardant, high-impact plastic case

4000 count large backlit LCD display

750V ac / 1000dc voltage measurement

600A ac current measurement

4000μA dc current measurement ideal for flame sensor testing

40MΩ resistance measurement.

4mF capacitance measurement

-40 °C to 400 °C type K thermocouple temperature measurement input & sensor

Continuity & diode test

Display hold function

32mm conductor jaw size

Complies with IEC 61010-1 CAT III 600V, CAT II 1000V

400A, including ac/dc voltage and resistance measurement.

600V a.c./d.c. voltage measurement

Continuity beeper below 30Ω

Auto shut-off to maximise battery life

Display hold keeps measurements on the display

Ergonomic control layout

30mm jaws

Lightweight design

Safety rating IEC 1010-2-032 (safety standard) Cat III 600V

Type Test Lead Connection Type Shrouded Right Angle Plug

measurement upto 400 Amps

10000 counts LCD display with annunciators

Auto sensing on ACV, DCV, Ω, ACA

600A ac measurement capability

750V ac/ 1000Vdc measurement range

2kΩ resistance range

Continuity and Diode Test

32mm conductor jaw capacity

Display hold

Auto–power off

Conforms to EN61010-1 (safety rating) CAT IV 600V, CAT III 1000V

3 3⁄4 digit LCD, 4000 count display

Auto-ranging

Convenient pocket size

40, 400Aac current measuring ranges

2% basic AC current accuracy

600Vac/dc voltage measurement

400Ω resistance range with continuity beeper below 40Ω

Data hold function

27mm conductor jaw capacity

Auto power-off

Powered by 2x AAA alkaline cells (supplied)

Safety to EN61010 - 1 CATIII 300V, CATII 600V

Description Stock no. Price per OM S$ S$ S$

Test leads 243-2998 unit 1+ 27·90

334 Additional Features:

Supplied with: 9V battery, carry case, test leads, type K thermocouple adaptor and

2000 count Large-scale LCD display

AC current measuring up to 400 Amps

Data Hold

Max Hold

Easy battery replacement

27mm dia. conductor size

1.2m Drop Proof

Auto power off to maximise battery life

Safety to EN61010-1 CAT. III 600V

Supplied with: Carrying case, test leads, 9V PP3 battery.

Supplied with: carry case, 2 x AA batteries, users instructions & test leads.

Back-lit display

In-rush current measurement

DC Voltage Accuracy ± (1.0% rdg + 2d) AC Voltage Range Resolution 0.1V DC Voltage Range 1.5V to 999V Resistance Accuracy ± (1.0 % rdg + 2d) DC Voltage Lowest Range Resolution 0.1V Resistance Range 2000Ω

AC Voltage Accuracy (50 to 500 Hz) ±(1.5% rdg + 3d) Resistance Range Resolution 0.1ΩAC Voltage Range 1.0V to 750V Dimensions & weight 200mm x 83mm x 40mm; 395g

Range/Resolution Accuracy

AC current 200A / 0.1A600A/1A

± 1.9% +5d, 50 to 60Hz±1.5% +5d (0 to 400A) 50-60Hz±2.5% +5d (400 to 600A) 50-60Hz

AC voltage 600V / 1V ±1.2% +3d 40Hz to 500Hz

Resistance 200Ω / 1Ω ±1.5% rdg +2dgt

Size (HxWxD) & Weight 200 x 76 x 41mm, 360g

type K bead sensor, users manual, vinyl belt pouch.

Supplied with: PP3 battery (installed), Manual, and Carrying case

Supplied with: Test leads, carry case, batteries.

Description Stock no. Price per OM S$ S$ S$

ICM A6 697-3998 unit 1+ 175·00

335 Additional Features:AC Current Range (50 - 60Hz) 20.0A 200.0A 400A Basic Accuracy (50 - 60Hz) ±(3.0%+0.05A) ±(2.0%+0.5A) ±(2.0%+5A) Conversion Type Average sensing Maximum Conductor Size 27mm dia Battery Life 200 hours typical Size (HxWxD) & Weight 56 x 180 x 32mm (WxLxH), 250g

Range Resolution Accuracy Frequency

Range

AC Current 40A 0.01A ± (2% reading + 10 digits) 50/60Hz

400A 0.1A ± (2% reading + 10 digits) 50/60Hz

DC Voltage 400V 0.1V ± (1% reading + 5 digits) –

600V 1V ± (1% reading + 5 digits) –

AC Voltage 400V 0.1V ± (1.5% reading + 10 digits) 40 - 600Hz

600V 1V ± (1.5% reading + 10 digits) 40 - 600Hz

Resistance 400Ω 0.1Ω ± (1% reading + 5 digits) –

Size (HxWxD) & Weight 192 x 64 x 31mm, 250g

Range Accuracy Resolution

Volts DC 4 to 1000V ±(0.9% + 2d) 1mV

Volts AC 4 to 750V ±(1.5% + 5d) 1mV

Current AC 0 to 600A ±(1.9% + 1A) 0.1A

Current DC 0 to 4000μA ±(1% + 2d) 0.1μA

Resistance 0 to 40MΩ ±(0.7% + 2d) 0.1Ω

Temperature -10 to 400 °C ±(1% + 4 °C) 0.1 °C

Capacitance 4nF to 4000μF ±(2.0% + 8d) 1pF

Continuity <=30Ω

Maximum jaw capacity 32mm

Dimensions & weight 212 x 84 x 40 mm, 390g

Description Stock no. Price per OM S$ S$ S$

ICM33 II 697-3976 unit 1+ 186·00

ICM33R II 697-3979 unit 1+ 205·00

Stock no. Price per OM S$ S$ S$

697-3960 unit 1+ 105·50

Stock no. Price per OM S$ S$ S$

697-3954 unit 1+ 235·00

True rms current measurement

Back-lit display

In-rush current measurement

Stock no. Price per OM S$ S$ S$

697-3709 unit 1+ 149·50

Supplied with: TL 75 test leads, soft carry case, 2 x AA batteries.

Contact RS for calibration requirements

Accessories

Description Stock no. Price per OM S$ S$ S$

H3 Holster 410-1242 unit 1+ 53·70

2250

www.nguyenxuong.com

Page 16: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Visit our website for additional price information and exciting promotions

Kyoritsu 2017 Digital AC Clamp Meter

Kyoritsu 2007A Clamp Meter

Kyoritsu 2002 PA Clamp Meter0 to 2000A

ICM133R 1000A ac,True-rmsreading

ICM135R 600A ac,True-rmsreading

Fluke 373

F3N True rms Clampmeter

Tear drop shaped jaws for use in tight spaces

Large backlit display

600 A ac current measurement with fixed jaws

600 V ac (true rms) and dc voltage measurement

Capacitance, resistance and continuity measurement

Display HOLD

CAT IV 300V, CAT III 600 V safety rating

Standards: IEC 61010-1 CAT III 600V, IEC 61010-2-031, IEC 61010-2-032

1000A ac current measurement

750Vac / 1000Vdc voltage measurement

Large 51mm dia. conductor jaw capacity

4000 count backlit digital display with analogue bargraph

True RMS reading on AC mode

Resistance & continuity beeper <30Ω

Display Hold & Min Max Function

10ms Peak Hold on ac A & ac V

Frequency Counter

Auto Power Off (30 minutes)

Separate battery compartment

600V circuit protection

Complies with EN61010 CAT. III 600V Safety Standard for industrial applications

Rugged construction with flame retardant, high impact plastic

This is a 700A ac general purpose current clamp meter

which is also able for measure current and frequency on

variable speed drives, switching power supplies and other

600A ac measurement

600V ac/dc voltage measurement

34mm dia. conductor jaw capacity

4000 count backlit LCD display with analogue bargraph

True RMS reading on AC mode

Resistance & continuity beeper <30Ω

Display Hold & Min Max Function

10ms Peak Hold on ac A & ac V

Frequency Counter

Auto Power Off (30 minutes)

Separate battery compartment

600V circuit protection

Complies with EN61010 CAT. III 600V Safety Standard for industrial applications

Digital display with maximum 4000 counts

Tear-drop shaped jaws for use in confined spaces

Data hold function

Sleep function to save battery

Standards: IEC61010-1CAT.III 300V; IEC61010-1CAT.II 600V;IEC61010-1CAT.I 1000V; IEC61010-2-031; IEC61010-2-032;IEC61326(EMC)

Terminal cover to avoid the use of incorrect terminals

Peak function to measure current peaks

Supplied with: Soft carry case, 2 x AA alkaline batteries and instructions

complex loads. Because of its unique set of functions the F3N

can be used for a wide range of power electronic applications:

measurement of peak motor start currents to determine the crest

factor, estimation of the harmonic content of a signal, recording

average consumption over a 24 hour (or other) period or check

for imbalances in motors, checking variable speed drives and

generator sets, etc.

Tear drop shaped jaws for ease of use in crowded

cable areas

Supplied with: Test leads, carry case, instruction leaflet and 9V PP3 alkaline battery.

Note: Colour may differ from that shown.

AC Current 400/600A±1.5% rdg ±4 dgt (50/60Hz)±2% rdg ±5 dgt (40∼400Hz)

AC Voltage 400/750V±1.2% rdg ±3dgt [50/60Hz]±1.5% rdg ±4dgt [40∼400Hz]

Resistance 400/4000Ω ±1.5% rdg ±2dgt Frequency Response 40Hz-400Hz Continuity Check buzzer sounds below 50Ω±35ΩConductor Size ∅33mm max. Withstand Voltage 3700V AC for 1 minute Dimensions 195(L) × 78(W) × 36(D)mm Weight 260g

Three functions of AC current, AC voltage & resistance

4-digit 10,000 count display with bar graph

True rms reading with crest factor capability of 5

Frequency measurement from 0.5Hz to 10kHz

Peak (2ms) mode enables measurement of half cycle peak

current values

Smooth mode averages last 3 readings to reduce display

Supplied with: Test leads, carry case, instruction leaflet and 9V PP3 alkaline battery.

ac voltage Basic Accuracy ±(1.9% rdg + 5d) 50-60Hz Ranges 400V & 750V Resistance

Resolution 0.1V & 1V Range 400ΩBasic Accuracy ±(1.0% rdg+ 5d)

50 to 500Hz Resolution 0.1Ω

dc voltage Basic Accuracy ±(1.0% rdg+ 3d) Ranges 400V & 1000V Frequency counter

Resolution 0.1V & 1V Ranges 4kHz & 10kHz Basic Accuracy ±(0.7% rdg+ 2d) Resolution 1Hz & 10Hz ac current Basic Accuracy ±(0.1% + 2d) @5V rms max Ranges 400A & 1000A Size (WxHxD) and Weight 90 x 275 x 51mm, 420g Resolution 0.1A & 1A

Standards: IEC 61010-1 CAT III 600V, IEC 61010-1 CAT II 1000V, IEC61010-2-031, IEC 61010-2-032

Note: Please contact RS for calibration requirements

AC A 400/2000A Conductor Size ∅55mm max. AC V 40/400/750V Power Source R6P(AA) (1.5V) x 2 approx. DC V 40/400/1000V 150 hours continuous use

400Ω/4k/40k/400k Ω Dimensions (mm) 247 (L) 105 (W) 49 (D) Continuity 400Ω Weight 470g approx. Output Voltage 400/2000A DC 400mV/200mV

Measurement Range Resolution Accuracy

AC Current 600 A 0.1 A 2% ± 5 digits

AC Voltage 600 V 0.1 V 1.5% ± 5 digits

DC Voltage 600 V 0.1 V 1% ± 5 digits

Resistance 6000 Ω 0.1 Ω 1% ± 5 digits

Capacitance 1000 μF 1 μF 1.9% ± 2 digits

Fixed jaw capacity 32mm diameter (750 MCM)

Stock no. Price per OM S$ S$ S$

255-027 unit 1+ 91·50

flicker on both current and frequency

Record mode allows the max., min. and average current or frequency to be displayed

Live bar graph displays the current whatever the operating mode

Designed to meet IEC 1010 600V CAT III safety standards

Stock no. Price per OM S$ S$ S$

697-3945 unit 1+ 265·00

ac voltage Basic Accuracy ±(1.9% rdg + 5d) 50-60Hz Ranges 400V & 600V Resistance

Resolution 0.1V & 1V Range 400ΩBasic Accuracy ±(1.0% rdg+ 5d)

50 to 500Hz Resolution 0.1Ω

dc voltage Basic Accuracy ±(1.0% rdg+ 3d) Ranges 400V & 600V Frequency counter

Resolution 0.1V & 1V Ranges 4kHz & 10kHz Basic Accuracy ±(0.7% rdg+ 2d) Resolution 1Hz & 10Hz ac current Basic Accuracy ±(0.1% + 2d) @5V rms max Ranges 400A & 600A Size (WxHxD) and Weight 76 x 220 x 50mm, 360g Resolution 0.1A & 1A AC A 200/600A

AC V 200/600V

Ω 200Ω buzzer sounds below 30 ±20Ω

Conductor size ∅33mm max.

Frequency Response 45Hz to 1kHz

Power Source 6F22 (9V) x 1

Dimensions (mm) 208 (L) 91 (W) 40 (D)

Weight 400g approx.

Stock no. Price per OM S$ S$ S$

420-0737 unit 1+ 270·00

Description Stock no. Price per OM S$ S$ S$

Fluke 373 705-1948S unit 1+ 328·00

Supplied with: Alkaline 9V PP3 battery (fitted), instruction manual, carrying holster with belt clip.

Stock no. Price per OM S$ S$ S$

697-3957 unit 1+ 215·00

Manu. Part

No.

Stock no. Price

per

OM S$ S$ S$

2017 420-1061 unit 1+ 117·00

Measuring range 0.3A to 400A trms (700A for sine) Accuracy 400A range ±5% of reading (400 - 700A) Range overload limits 700A rms or 1000A crest Frequency Current measurement 10Hz to 1kHz

Frequency measurement 0.5Hz to10kHz

Accuracy 40A range ±(2% rdg +20 digits) Crest factor 2.5 max. at 400A at 45 to 65Hz 5 max. at 40A at 45 to 65Hz

Accuracy 400A range ±2% of reading (<400A) Size (WxHxD) andweight

98 x 232 x 44mm, 500g

Stock no. Price per OM S$ S$ S$

206-624 unit 1+ 630·00

2251

www.nguyenxuong.com

Page 17: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Leakage Current Clampmeters

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple

Sanwa DCM60L

AVO DCM 300E

ISO-TECH ILCM03

Fluke 360 AC Leakage Current ClampMeter

Kyoritsu 2413R True RMS

Kyoritsu 2431

Kyoritsu 2027 Digital ClampMeter True RMS

Kyoritsu 2031 Compact ACCurrent

A 3 1⁄2 digit ac hand held ac clamp meter offering a cost

effective solution for general purpose use. External test

leads are supplied for use where direct measurements are

required.

Compact, light weight and easy-to-use

Rotary switch for easy one finger power-on and

range selection

Large 4000 count 3 3⁄4 digit LCD with analogue bar graph

40mA, 400mA, 4A, 40A, 100A measuring ranges

10μA ultra high resolution

30mm diameter conductor jaw capacity

400Vac voltage range

400Ω resistance and continuity range with beeper below

Large 68mm capacity jaws enable clamping of all

three or four wires of 3-phase systems for leakage

current measurement.

Tear drop shaped jaws for ease of use in confined spaces

Non-invasive measurement of leakage current with 3 mA range and 1 μA of

resolution, for accurate monitoring of insulation erosion

Advanced shielding to ensure accurate results when measuring near other

conductors

Automatic ranging within the manually selected mA or A range

3200 count LCD and bargraph display with wide display angle for easily viewing

measurements

Display-HOLD for convenience when measuring in hard to see locations

Broad range of measurements currents up to 60 A for all installation needs

Easy carrying, pocket sized clamp fits into tight spaces

40mm jaw size

Auto power off with audible warning buzzer

Complies with EN61010 -1 CAT II 300V

Perfect fit to the palm of your hand

3 1⁄2 digit compact design

25mm clamp diameter

Data hold function

IEC 1010 CAT II 600V, CE mark

Sensitve 20mA range has resolution of 0.01mA

Teardrop shaped jaws for use in confined spaces

Frequency filter to eliminate the effect of harmonics

Auto power-off function (automatically turns off after 10

minutes)

Measures from mA up to 1000A

True RMS readings give accurate measurements of distorted waveforms.

Switchable frequency filter to eliminate the effect of the harmonics.

2-way analogue output terminal: Measured AC current is converted to AC

and DC output voltage.

Peak hold function (Selectable 10 or 100ms response time)

Data hold function allows easy reading in dimly lit or hard-to-reach locations

LCD back-light facility (Defaults to "off")

Data hold function

Auto-power off

True RMS sensing

Supplied with: carry case, 3V Lithium battery & instruction manual.

40Ω

Auto power off selectable

Max./min. function

Zero/relative value function

Data hold function

Safety to EN61010 CAT III 300V

Fully IEC1010-1 and IEC101-2-032

compliant for circuits up to 500V

phase to phase or 300V phase to earth

CAT III or 600V CAT II

Continuity buzzer

Contact RS for calibration requirements

Standards: IEC61010-1 CAT.III 300V, IEC61010-2-032

Standards: IEC 61010-1 CAT III 600V, IEC 61010-2-031, IEC 61010-2-032

Standards: IEC61010-1 CAT.III 300V Pollution degree 2, IEC61010-2-032

Supplied with: Carrying case, 2 AAA batteries

Standards: IEC 61010-1 CAT III 300V

AC A 20/200A Power Source 1.5V button cell x2 type LR-44 Conductor Size ∅24mm max. Dimensions (mm) 147 (L) 58.5 (W) 26 (D) Frequency response 50Hz to 1kHz Weight 100g approx. Withstand Voltage 3700V AC for 1 minute

Function Range Ohms 0.1 to 200Ω

ac Voltage (Autorange) 0.1 to 200V and 1 to 600V Continuity Approx. 100Ω

ac Current (Autorange) 0.1 to 200A and 1 to 600A

Supplied with: Carry case, battery and instruction manual

30mA and 300mA ranges for leakage current

measurement

0.01mA resolution on 30mA range

30A and 300A ranges for power measurements

Data hold facility

Maximum conductor size 40mm diameter

3200 count LCD display with analogue bar graph

Range Resolution Accuracy

AC Current 50-60Hz 40Hz-1kHz 40mA 10μA ±(1.5% rdg + 3d) ±(2% rdg + 5d) 400mA 100μA ±(1.5% rdg + 3d) ±(2% rdg + 5d) 4A 1mA ±(1.5% rdg + 3d) ±(2% rdg + 5d) 40A 10mA ±(1.5% rdg + 3d) ±(2% rdg + 5d) 100A 100mA ±(2.2% rdg + 5d)* ±(2.5% rdg + 5d)* AC Voltage

400V 0.1V ±(1% rdg + 3d) ±(2% rdg + 4d) Resistance

400Ω 0.1Ω ±(1% rdg + 3d) Size (HxWxD) and Weight 210 x 62 x 36mm, 200g

* Specified accuracy applies only up to 80A

Function Range Resolution Accuracy

Current AC 50/60 Hz 3mA30mA30A60A

0.001mA0.01mA0.01A0.1A

±(1% + 5d)±(1% + 5d)±(1% + 5d) (0 ∼ 50A)±(5% + 5d) (50∼60A)

Battery life 90 hours approx (continuous use)

Dimensions & weight 176mm x 70mm x 25mm : 220g

Supplied with: Carry case, 2 x LR-44 battery and instruction

AC A 200/600A (True RMS) Frequency Response 40Hz to 1kHz AC V 200/600V (True RMS) Power Source 6F22 (9V) x 1 Ω 200Ω buzzer sounds below 30 ±20Ω Dimensions (mm) 208 (L) 91 (W) 40 (D) Conductor Size ∅33mm max. Weight 400g approx.

Supplied with: Batteries, instruction manual, carrying case.

manual

Stock no. Price per OM S$ S$ S$

420-1055 unit 1+ 137·00

Stock no. Price per OM S$ S$ S$

384-1270 unit 1+ 113·00

Technical Specification - Ranges and Accuracy

Range Accuracy, filter "50-60Hz" Accuracy, filter "Wide" Accuracy, filter "Wide"

50/60Hz input 50/60Hz input 40-1000Hz input

200mA, 2A, 20A ± (2.5% reading + 5 digits) ± (1.8% reading + 5 digits) ± (3% reading + 5 digits)

200A, 1000A (<500A) ± (3% reading + 5 digits) ± (2% reading + 5 digits) ± (3.5% reading + 5 digits)

1000A (>500A) ± 5.5% reading ± 5% reading

Stock no. Price per OM S$ S$ S$

252-191S unit 1+ 1190·00

Stock no. Price per OM S$ S$ S$

697-3721 unit 1+ 530·00

Stock no. Price per OM S$ S$ S$

420-1077 unit 1+ 158·50

Conductor Size Ø 68mm max. Crest Factor 3.0 or less Frequency Response40Hz - 1kHz Withstand Voltage 3700Vac for 1 minute Measurementmethod

True RMS Power Source 6F22 (9V PP3) Opearting life approx. 60hours

Analogue Output 200mV ac/dc for full scale (2000-count)reading

Size (LxWxD) andWeight

250 × 130 × 50mm, approx 600 g

ac leakage current (mA) 30 & 300 Accuracy ±(1.2% rdg +5 digits) 0-200A±(5% rdg +5 digits) 300A

ac current (A) 30 & 300 Power 2 x 1.5 V Button Cells LR44 or SR44 Resolution 0.01mA (30/300mA range)

0.01A (30/300A range) Size (HxWxD) and Weight 176 x 64 x 23mm, 125g

Technical Specification - Ranges and Accuracy

Range Accuracy, filter ’’50-60Hz’’ Accuracy, filter "Wide’’ Accuracy, filter "Wide"

50/60Hz input 50/60Hz input 40-400Hz input

20mA, 200mA, 200A (<100A) ± (3% reading + 5 digits) ± (2% reading + 4 digits) ± (5% reading + 6 digits)

200A (>100A) ± (5% reading + 5 digits) ± (5% reading + 4 digits) –

Stock no. Price per OM S$ S$ S$

543-847 unit 1+ 980·00

Conductor Size Ø 24mm max. Measurement method Average value Frequency Response 40 - 400Hz Effect of external stray magnetic field Ø15mm @ 100A 10mA AC max. Withstand Voltage 3700V AC for 1 minute Power Source 2 × LR44 (1.5V button cell) Size (LxWxD) and Weight 149 × 60 × 26mm, approx. 120 g

Stock no. Price per OM S$ S$ S$

247-0142S unit 1+ 910·00

Stock no. Price per OM S$ S$ S$

543-295 unit 1+ 530·00

2252

www.nguyenxuong.com

Page 18: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

AC & DC Digital Clampmeters

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

New products available online every week

Fluke 374 and 375

ICM 36R

ICM 136R (true r.m.s. reading)

ICM30 & ICM30R

Kew 5000 & 5001 Data Loggers

A current clamp using Hall effect technology to measure a.c.

Leakage current data logger with 3 input channels and ability to record

continuously for up to 25 days (40 days with model 5001)

Clamp multimeter utilising Hall effect technology and nickel

Measure a.c. and d.c. current up to 300A.

Large backlit display

600 A ac and dc current measurement with fixed jaws

2500 A ac current measurement with optional iFlex flexible current probe

600 V ac (true rms) and dc voltage measurement

Capacitance, resistance and continuity measurement

Display HOLD, Min, max, average and inrush recording

CAT IV 600V, CAT III 1000 V safety rating

Hall effect technology

Auto-ranging

4000 cound LCD display

Continuity beeper

Auto-zeroing key for d.c. current range

375 additional feature

and d.c. current up to 600A.

steel alloy jaws for precise measurement of ac and dc current up to 600A.

True RMS measurement of leakage current

Data is stored in non-volatile memory ensuring retention even after battery

exhaustion

4-stage display of remaining battery life

Information such as present time, recording interval, start of recording and

recording method can be set by using supplied software

Selection of one-time or endless logging modes*

Recall function - Latest 10 sets of data can be checked

Recorded data can be transfered to PC via USB link

Supplied "KEW LOG soft 2" software allows graphing and processing of data

on PC

True rms reading in ac current measurement

2000 count LCD display

Jaw capacity up to 34mm diameter or 20 × 40 mm conductor

Zero adjust knob for d.c. ranges

Display hold function

Auto power down to conserve battery life

Designed to meet IEC 61010-01 (safety standard) 300V Cat III pollution degree 2

Data hold function

MAX hold function

600V protection in every range

Auto power off selectable

* One time mode: Recording stops when the memory is full, Endless mode:

oldest data overwriten by latest data

500mV dc measurement range to interface with other accessories

Frequency measurement

Low pass filter for stable readings in noisy environments

Backlit 4000 count LCD display with analogue bargraph

True r.m.s. reading on ac mode

600A ac/dc current measurement

600V ac/dc voltage measurement

Resistance measurement with continuity beeper

Display hold & peak hold (10ms)

Maximum Conduct Size of 35mm diameter

Maximum Busbar Size: 40×15mm

DCA zeroing key

Min/max function

Frequency counter

Auto power off

Supplied with: Soft carry case, 2 x AA alkaline batteries and instructions

ICM30R has true rms reading in both a.c. current and a.c. voltage measurement.

Standards: EN61010 CAT. III 600V

Note: Kew 8481 current clamp (547-865) must be purchased separately

Supplied with: deluxe carrying case, alkaline PP3 battery (fitted) and instruction

booklet.

Supplied with: Test leads, battery, carry case and instructions

Note: Please contact RS for calibration requirements

Dual Hall sensor nickel-steel alloy jaw mechanism

1.0% basic dc/ac current accuracy

22mm diameter conductor jaw capacity

Safety to EN 61010-1 CAT III 300V, CAT II 600V

Maximum a.c. Current (A) 600 Resolution d.c. Current (mA) 100 Resolution a.c. Current (A) 0.1 Basic Accuracy d.c. Current ± 1.9% Rdg +2 digits Basic Accuracy a.c. Current ±1.5% rdg +5 digits Size (HxWxD) and Weight 203 x 81 x 39mm,

310g Maximum d.c. Current (A) 600

Supplied with: Manual, LR6 alkaline battery, software, USB cable & portable case

Stock no. Price per OM S$ S$ S$

697-3982 unit 1+ 240·00

Range Resolution Accuracy

AC Current 400A 0.1A ±(1.9% rdg + 5d) 50-60Hz 600A 1A ±(1.9% rdg + 5d) 50-60Hz

AC Voltage 400V 0.1V ±(1% rdg + 5d) 50-500Hz 600V 1V ±(1% rdg + 5d) 50-500Hz

DC Current 400A 0.1A ±(1.5% rdg + 5d) 600A 1A ±(1.5% rdg + 5d)

DC Voltage 400V 0.1V ±(0.7% rdg + 2d) 600V 1V ±(0.7% rdg + 2d)

Resistance 400Ω 0.1Ω ±(1% rdg + 3d) Frequency 4kHz 1Hz ±(0.1% rdg + 2d) Size (HxWxD) and Weight 235 x 88 x 52mm, 280g

Note: Colour may differ from that shown.

Standards: IEC 61010-1:2001 CAT.III 300V Pollution degree 2, IEC 61326 (EMC Standard)

Measurement Range Resolution Accuracy

AC Current via Jaw 600 A 0.1 A ± (2% + 5 d)

AC Current via iFlex (optional) 2500 A 0.1 A ± (3% + 5 d)

DC Current 600 A 0.1 A ± (2% + 5 d)

AC Voltage 600 V 0.1 V ± (1.5% + 5 d)

DC Voltage 600 V 0.1 V (374)0.1 mV (375)

± (1% + 5 d)

Resistance 6000 Ω (374)60000 Ω (375)

0.1 Ω ± (1% + 5 d)

Frequency (375 only) 500 Hz 0.1 Hz ± (0.5% + 5 d)

Capacitance 1000 μF 1 μF ± (1% + 4 d)

Fixed jaw capacity 32mm diameter (750 MCM or 2-500 MCM)

Description Stock no. Price per OM S$ S$ S$

Fluke 374 705-1939S unit 1+ 466·00

Fluke 375 705-1935S unit 1+ 535·00

Stock no. Price per OM S$ S$ S$

697-3932 unit 1+ 250·00

Supplied with: carrying case, test leads and two AA batteries.

Input AC Voltage, 100mV//A

Maximum input AC 170mV rms, 250mV Peak

A-D conversion Successive Approximation

Measurement method True RMS value

Memory capacity 3 ch. @ 20,000 readings, or 1 ch. @ 60,000 readings

Measurement Interval 1, 2, 5, 10, 15, 20, 30 sec., 1, 2, 5, 10, 15, 20, 30, 60 min.

Maximum Display 1049 counts

Over-range indication Display of

Insulation resistance Over 50MΩ @ 1000V

Size and Weight Model 5000: 111 x 60 x 36 mm, 255 g

Model 5001: 111 x 60 x 42 mm, 315 g

Power Model 5000: Alkaline battery LR6 x 4

Model 5001: Alkaline battery LR6 x 6

Maximum a.c. Current (A) 300 Maximum d.c. Voltage (V) 600 Resolution a.c. Current (mA) 10 Resolution d.c. Voltage (mV) 0.1 Basic Accuracy a.c. Current (%,mA) ±(3% rdg +3 digits)

(50 to 60 Hz) Basic Accuracy d.c. Voltage (V, mV) ± (0.5% rdg + 2

digits) Maximum d.c. Current (A) 300 A Resistance Range 400Ω to 40MΩ

Resolution d.c. Current (A, mA) 10 mA Resistance Resolution (Ohms) 10KΩ (40 MΩ

range) Basic Accuracy d.c. current (A, mA) ±(2% rdg +2 digits) Resistance Accuracy (%, Ohms) ±(2.5% rdg +5 digits)Maximum a.c. Voltage (V) 600 Maximum Jaw Capacity (mm) 22 Resolution a.c. Voltage (V) 1 Size (HxWxD) and Weight 192 x 66 x 27mm,

205g Basic Accuracy a.c. Voltage (%, Mv, V) ± (1.5% rdg +5

digits)

Cross-reference to manufacturer’s part no.

Kyoritsu part no Stock no.

5000 543-831

5001 543-841

8141 547-865

Description Stock no. Price per OM S$ S$ S$

Kew 5000 Leakage Logger 543-831 unit 1+ 1910·00

Kew 5001 Leakage Logger 543-841 unit 1+ 1910·00

Leakage Current Clamp 547-865 unit 1+ 440·00

Description Stock no. Price per OM S$ S$ S$

ICM30 697-3963 unit 1+ 240·00

ICM30R 697-3967 unit 1+ 270·00

2253

www.nguyenxuong.com

Page 19: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple

F15 True RMS

Fluke H3 Holster Accessory for the 321/322/333/334/335/336 and 337

Fluke 321 & 322

www.rssingapore.com

Fluke 381 Remote Display True-rms AC/DC Clamp Meter

Fluke 376 True-rms AC/DC Clamp Meterwith iFlex

Fluke iFlex Flexible Current Probes

Fluke 321

Dimensions: 231x90x64 mm

2500 A ac current measurement with select Fluke meters

Works with frequency, inrush, and min/max functions on

select Fluke meters

Large loop size and thin 7.5mm cross section allow

measurement of awkward sized conductors with

improved access in crowded spaces

CAT IV 600V, CAT III 1000 V safety rating

Compatible with Fluke 374, 375, 376 & 381 clamp meters

Wireless technology allows the display to be carried up to

10m away from the point of measurement for added

flexibility

Removable magnetic backlit display can be conveniently

mounted where it is easily seen

1000 A ac and dc current measurement with fixed jaws

2500 A ac current measurement with iFlex flexible current

probe

1000 V ac (true rms) and dc voltage measurement

Frequency, resistance and continuity measurement

Display HOLD, Min, max, average and inrush recording

Large backlit display

1000 A ac and dc current measurement with fixed jaws

2500 A ac current measurement with iFlex flexible current

probe

1000 V ac (true rms) and dc voltage measurement

500mV dc measurement range to interface with other

accessories

Frequency, capacitance, resistance and continuity

measurement

Display HOLD, Min, max, average and inrush recording

Contact RS for calibration requirements

Measurement Capability

True ac/dc rms current measurement (ac, dc, sinusoidal

or distorted)

Current up to 1000A a.c./1400A d.c.

Low pass filter for stable readings in noisy environments

CAT IV 600V, CAT III 1000 V safety rating

Low pass filter for stable readings in noisy environments

CAT IV 600V, CAT III 1000 V safety rating

600Vac/dc measurement

4kHz frequency measurement (voltage or current)

4MΩ resistance measurement (mains proof) and continuity

beeper

Auto-ranging with manual override for faster readings

Min./max measurement - ideal for momentary voltage or

current peaks (in rush current)

Display HOLD

Diode Test function

Complies with EN61010-2-032 CAT III 600V

Supplied with: 18in iFlex current probe, soft carry case, 2 x AA alkaline batteries and instructions

Fluke 322

Supplied with: 18in iFlex current probe, TL75 test leads, soft carry case, 5 x AAA alkaline batteries

and instructions

Note: Please contact RS for calibration requirements

Accessories

Supplied with: carry case, test lead set, 9V alkaline PP3 battery

Note: Please contact RS for calibration requirements

Description Stock no. Price per OM S$ S$ S$

H3 Holster 410-1242 unit 1+ 53·70

Note: Please contact RS for calibration requirements

Measurement Range Resolution Accuracy

AC Current* 2500 A 0.1 A 3% ± 5 digits

Frequency* 500 Hz 0.1 Hz 0.5% ± 5 digits

External magnetic field rejection 40 dB (with cable >10 cm from the coupling)

Inrush When used with compatible Fluke meter

* Accuracy stated includes probe and meter accuracy

New smaller size fits easily into tight places

Precise measurements with 1.8% basic accuracy

Resolution up to 0.1A and 0.1V AC

Measures AC current to 400 A

Measures AC voltage to 600 V

Resistance measurement to 400 Ω

Continuity for quick checking of shorts

Display hold function

Automatic low battery indicator

Auto power-off function

Fluke 322 only:

and instruction manual.

Measurement Range Resolution Accuracy

AC Current via Jaw 1000 A 0.1 A ±(2% + 5 d)

AC Current via iFlex 2500 A 0.1 A ±(3% + 5 d)

DC Current 1000 A 0.1 A ±(2% + 5 d)

AC Voltage 1000 V 0.1 V ±(1.5% + 5 d)

DC Voltage 1000 V 0.1 mV ±(1% + 5 d)

Resistance 60000 Ω 0.1 Ω ±(1% + 5 d)

Frequency 500 Hz 0.1 Hz ±(0.5% + 5 d)

Capacitance 1000 μF 1 μF ±(1% + 4 d)

Fixed jaw capacity 32mm diameter (750 MCM or 2-500 MCM)

Description Stock no. Price per OM S$ S$ S$

I2500-10 10 in. iFLEX probe 705-1945S unit 1+ 173·00

I2500-18 18 in. iFLEX probe 705-1954S unit 1+ 173·00

Measurement Range Resolution Accuracy

AC Current via Jaw 1000 A 0.1 A ± (2% + 5 d)

AC Current via iFlex 2500 A 0.1 A ± (3% + 5 d)

DC Current 1000 A 0.1 A ± (2% + 5 d)

AC Voltage 1000 V 0.1 V ± (1.5% + 5 d)

DC Voltage 1000 V 0.1 V ± (1% + 5 d)

Resistance 60000 Ω 0.1 Ω ± (1% + 5 d)

Frequency 500 Hz 0.1 Hz ± (0.5% + 5 d)

Fixed jaw capacity 32mm diameter (750 MCM or 2-500 MCM)

Stock no. Price per OM S$ S$ S$

705-1932S unit 1+ 664·00

DC voltage measurement capability

Additional 40A AC current range gives 0.01A resolution

Current ranges (ac/dc) 400A & 1000A Frequency resolution 0.01Hz, 0.1Hz, 1Hz Current resolution (ac/dc) 0.1A & 1A Requency accuracy ±(0.1% rdg + 15 digits) Maximum measurement 1000A ac, 1400A dc Resistance ranges 400Ω, 4kΩ, 40kΩ, 400kΩ,

4MΩ

Basic accuracy ac/dc current±(2.5% rdg + 2 digits) Resistance resolution 0.1Ω, 1Ω, 10Ω, 100Ω, 1KΩ

Voltage ranges (ac/dc) 400mV, 4V, 40V, 400V, 600V Accuracy resistance < 400Ω ±(1.5% rdg + 7 digits) Voltage resolution (ac/dc) 0.1mV, 1mV, 10mV, 100mV, 1V Accuracy resistance > 400Ω ±(1.5% rdg + 4 digits) Basic accuracy ac voltage ±(1.5% rdg + 2 digits) Continuity buzzer threshold 40Ω on 400Ω range Basic accuracy dc voltage ±(1% rdg + 2 digits) Maximum Jaw Capacity (mm) 42 (Dia); 50 x 5 (Bus bar) Frequency ranges 100Hz, 1kHz, 4kHz Size (HxWxD) and Weight 254 x 97 x 46mm, 600g

Stock no. Price per OM S$ S$ S$

705-1923S unit 1+ 1014·00

Contact RS for calibration requirements.

Stock no. Price per OM S$ S$ S$

207-4435 unit 1+ 510·00

Standards: IEC 1010-2-032, 600V CAT IIISupplied with: Carry case, test leads & instruction manual

Fluke 321 Fluke 322

Voltage DC – 0 - 600 V

Voltage DC resolution – 1 V

Voltage DC Accuracy – 1% ± 5 counts

Voltage AC 0 - 400 V 0 - 400 V

Voltage AC resolution 0.1 V 0.1 V

Voltage AC max 0 - 600 V 0 - 600 V

Voltage AC resolution 1 V 1 V

Voltage AC Accuracy 1.2% ± 5 counts (50 - 400 Hz)

Current AC 0 - 400 A 0 - 400 A

Current AC resolution 0.1 A 0.1 A

Current AC max – 0 - 40 A

Current AC resolution – 0.01 A

Current AC Accuracy 1.8% ± 5 counts (50 - 60 Hz)

3.0% ± 5 counts (60 - 400 Hz)

Resistance Range 0 - 400 Ω 0 - 400 Ω

Resistance resolution 0.1 Ω 0.1 Ω

Resistance Accuracy 1% ± 5 counts

Continuity Buzzer Operates at < 30 Ω on Resistance measurements

Operating Temperature -10°C to +50°C

Storage Temperature -30°C to +60°C

Power source 2 x AAA battery, typical life 100 hours (Zinc Carbon)

Size and Weight 190 x 63 x 35 mm, 230 g

Temperature de-rating of measurement accuracy:Add 0.1x specified accuracy for each °C above 28°C or below 18°C

Model Stock no. Price per OM S$ S$ S$

Fluke 321 543-318 unit 1+ 190·00

Fluke 322 543-314 unit 1+ 200·00

2254

www.nguyenxuong.com

Page 20: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Many more leading brands from over 2,500 suppliers available online

Kyoritsu 2033 AC/DC Current Mini Clamp Meter

Kyoritsu 2009A AC/DC 0 to 2009A True RMS

Kyoritsu 2003A AC/DC 0 to 2000A

Fluke 355 True-RMS, 2000A AC/DC

Fluke 353 True-RMS, 2000A AC/DC

ICM139R 1000A AC/DC,True-rms reading

ICM2000

4000 count backlit display

4000 count backlit digital display with analogue bargraph

True RMS reading on a.c. mode

NickelSteel alloy jaw mechanism

1000A a.c./d.c. current measurement

1000V a.c./d.c. voltage measurement

Resistance & continuity beeper <30Ω

Display hold & Min Max Function

10ms peak Hold on ACA & ACV

Frequency Counter

Auto Power Off (30 minutes)

51mm dia. conductor jaw capacity

Separate battery compartment

Complies with EN61010 CAT. IV 600V/ CAT. III 1000V Safety Standard for industrial

applications

4000 count backlit display

Tear drop jaws for ease of use in confined areas

Accurate True RMS reading of AC current and

voltage regardless of the whole waveform

Average function for fluctuating current and voltage

A 2000A a.c./d.c. clamp meter designed to meet BSEN61010 &

24mm diameter tear drop shaped jaws

Minimum resolution of 0.01A AC&DC

Data hold function

Auto zero function for one touch zero adjustment

Tear drop shaped jaws for use in tight spaces

Auto-Null function for one-touch zero adjustment

Maximum measurement function for ease of

reading peak currents over a period of time

Standards: IEC 61010-1 CAT III 600V, IEC 61010-1 CAT II 1000V, IEC61010-2-031, IEC 61010-2-032

Supplied with: Test leads, carry case, instruction leaflet and 9V PP3 alkaline battery.

measurements

BSEN61010-2-032 600V cat III.

True-RMS AC + DC current & voltage measurement

True RMS crest factor = 2.4

Motor inrush current measurement

Min/Max/Average recording mode

Frequency Measurement

Voltage AC/DC

Resistance measurement

Continuity measurement with beeper

58mm dia conductor jaw capacity

Safety to EN61010 CAT IV 600 V, CAT III 1000 V

True-RMS AC + DC measurements

True RMS crest factor = 2.4

Motor inrush current measurement

Min/Max/Average recording mode

Frequency Measurement

58mm dia conductor jaw capacity

Safety to EN61010 CAT IV 600 V, CAT III 1000 VStandards: IEC 61010-1 CAT III 300V, IEC 61010-2-032

Standards: IEC 61010-1 CAT III 600V, IEC 61010-1 CAT II 1000V, IEC61010-2-031, IEC 61010-2-032

Range/Resolution Basic Accuracy

a.c. voltage 400V/0.1V 750V/1V

±(1.0% rdg+5d) 50 to 500Hz

d.c. voltage 400V,/0.1V 1000V/1V

±(0.7% rdg+ 2d)

a.c. current 400A,/0.1A 1000A/1A

±(1.5% rdg+ 5d) 50Hz/60Hz ±(1.9% rdg+ 7d) 50Hz/60Hz

d.c. current 400A,/0.1A 1000A/1A

±(1.0% rdg+ 3d)±(1.9% rdg+ 7d)

Resistance 400Ω/0.1Ω ±(1.0% rdg+ 3d)

Frequency counter 20 to 400Hz/1Hz ±(0.1% + 2d) @ 5V rms max

Size (HxWxD) and Weight 275 x 90 x 51mm, 420g

Additional error due to remanence: 1% of current peak max.

AC A 400/2000A Output Voltage 400/2000A, DC 400mV/200mV AC V 400/750V Conductor Size ∅55mm max. DC A 400/2000A Power Source R6P(AA) (1.5V) x 2 DC V 400/1000V Approx. 100hours in continuous use Ω 400/4000Ω Dimensions (mm) 250 (L) 105 (W) 49 (D) Continuity 400Ω Weight 530g approx.

Supplied with: C43 soft case, 6 AA alkaline batteries, TL224 1.5m silicone test leads,

TP2 slim reach probes (2 mm), AC285 crocodile clips and users manual

Supplied with: C43 soft case, 6 AA batteries and users manual

4000 count LCD display

DC current measurements to 2500A

AC current, true rms and Crest Factor to 2000A

AC/DC voltage to 600V

Max./min. hold

Resistance and continuity measurement

Diode Test

Frequency measurement

Low battery indication

Digital and bar graph display

AC A 40/300A (Autoranging) Power Source 1.5V button cell x 2 type LR-44 or SR-44 DC A 40/300A (Autoranging) Dimensions (mm) 147 (L) 59 (W) 25 (D) Conductor Size ∅24mm max. Weight 100g approx.

AC A 400/2000A Output Voltage 400/2000A, DC 400mV/200mV AC V 40/400/750V Conductor Size ∅55mm max. DC A 400/2000A Power Source 6F22(9V) x 1 approx. DC V 40/400/1000V 15 hours in continuous use Ω 400/4000Ω Dimensions (mm) 250 (L) 105 (W) 49 (D) Continuity 400Ω Weight 540g approx. Frequency 10 to 4000Hz

Stock no. Price per OM S$ S$ S$

420-0765 unit 1+ 270·00

Stock no. Price per OM S$ S$ S$

420-0743 unit 1+ 500·00

Stock no. Price per OM S$ S$ S$

697-3951 unit 1+ 405·00

Contact RS for calibration requirements

Contact RS for calibration requirements

Note: Colour may differ from that shown.

Stock no. Price per OM S$ S$ S$

420-0759 unit 1+ 570·00

Voltage Range AC/DC 0-4.000 V, 0-40.00 V, 0-400.0 V, 0-600 V ACrms, 0-1000 V DC

Basic Accuracy 1% ± 5 counts

Current Range AC/DC 0-40.00 A, 0-400.0 A, 0-2000 A; 1400 AC rms

Basic Accuracy 1.5% ± 5 counts

Resistance range 0-400.0 Ω, 0-4.000 kΩ, 0-40.00 kΩ, 0-400.0 kΩ

1.5% ± 5 counts

Frequency Measurement Range 5.0Hz to 100Hz 101Hz to 1kHz

Basic Accuracy 0.2% ± 2 counts 0.5% ± 5 counts

Size (H x W x D) and weight 300 x 98 x 52mm: 814g

Current Range AC/DC 0-40.00 A, 0-400.0 A, 0-2000 A, 1400 AC rms

Basic Accuracy 1.5% ± 5 counts 1.5% ± 5 counts

Frequency Measurement Range 5.0Hz to 100Hz 101Hz to 1kHz

Basic Accuracy 0.2% ± 2 counts 0.5% ± 5 counts

Size (H x W x D) and weight 300 x 98 x 52mm: 814g

Maximum a.c. current 2100A Maximum d.c. voltage (V) 0.4; 4 ; 40; 400; 600 Resolution a.c. current (A) 0.1 (400 A); 1 (1000 A); 1 (2100

A) Resolution d.c. voltage 0.1 mV (400 mV); 0.001 V (4 V);

0.01 V (40 V); 0.1 V (400 V); 1 V (600 V)

Basic accuracy a.c. current ± 3% ± 5 digits (40 to 1 kHz) Basic accuracy d.c. voltage ± 1.5% Rdg ± 3 digits Maximum d.c. current (A) 400; 2000; 2500 Resistance range (Ω) 400; 4 kΩ; 40 kΩ;

400 kΩ; 4 MΩ; 40 MΩ

Resolution d.c. current (A) 0.1 (400 A); 1 (2000 A); 1 (2500A)

Resistance resolution (Ω) 0.1 (400 Ω); 1 (4 kΩ); 10 (40 kΩ); 100 Ω (400 kΩ); 1 kΩ (4 MΩ); 10 kΩ (40 MΩ)

Basic accuracy d.c. current ± 2% Rdg ± 3 digits Resistance accuracy ± 1.5% Rdg ± 3 digits Maximum a.c. voltage (V) 0.4; 4; 40; 400; 600 Maximum jaw capacity

(mm) 55 (Dia); 65 x 24 (Bus bar)

Resolution a.c. voltage 0.1 mV (400 mV); 0.001 V (4 V); 0.01 V (40 V); 0.1 V (400 V); 1 V (600 V)

Size (HxWxD) and Weight 271 x 112 x 46mm, 647g

Basic accuracy a.c. voltage ± 2% Rdg ± 5 digits (40 to 1 kHz)Power supply 9V PP3 battery

Stock no. Price per OM S$ S$ S$

411-970S unit 1+ 1299·00

Stock no. Price per OM S$ S$ S$

411-974S unit 1+ 1083·00

Stock no. Price per OM S$ S$ S$

697-3702 unit 1+ 500·00

2255

www.nguyenxuong.com

Page 21: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Process Clamp Meters

HVAC Clampmeters

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple

Fork Current Tester 2300R

Sanwa DCM400 Series Clamp Meter

Fluke 771 mA Process Clamp Meter

Fluke 902 HVAC Current Clamp

www.rssingapore.com

Kyoritsu 2037 Clampmeter

2046R AC/DC True RMS Clamp Meter

2300R features:

High accuracy auto-ranging True RMS AC/DC Clamp

Multimeter

CAT.IV Clamp Meters can measure voltages and

currents in both very low and high power circuits

6039 counts with Bar Graph display

Red LED, as "Non Contact Voltage" function, gives

Able to measure current frequency

4000 count display

Voltage frequency measurement range up to 10MHz

To IEC1010 CATIII 300V, CATII 600V

Measure mA signals for PLC and control system analog I/O

Teardrop shaped jaws for use in confined spaces

Measure 4 to 20 mA output signals from transmitters without breaking the loop

Hold function captures and displays changing measurements

Dual backlit display with both mA measurement and percent of 4 to 20 mA span

Measurement spotlight illuminates hard to see wires in dark enclosures

Detachable clamp head with extension cable for measurements in tight locations

Measure 10 to 50 mA signals in older control systems using the 99.9 mA range

Non-contact voltage function

True RMS Reading

DCM 400

warning to the user of the presence of AC Voltages

MIN/MAX measurement function

Double-moulded case construction gives comfortable handling

Applications include power distribution, power utilities and maintenance

fields

600V ac/dc voltage measurement

600A ac current measurement

200μA dc current measurement ideal for flame sensor testing

Resistance and capacitance measurement

Auto Power-Off

Data Hold (AC A/DC A Only)

4000-count LCD display

Measures both AC and DC current and voltage

True RMS reading permits precise measurements of non-sinusoidal AC

currents and voltages

AC measurements extend down to 10 Hz

Normal, Average, Peak or Frequency reading selection

Supplied with: 2 AA batteries, soft carry case and user manual.

Standards: IEC 61010-1 CAT.IV 600V; IEC61010-031; IEC61010-2-032; IEC61326

Frequency measurement by clamp or test leads

DCM 400 AD

Standards: IEC61010-1 CAT.III 600V Pollution Degree 2, IEC61010-2-031

Function Range Resolution Accuracy

Measure 4-20mA -20.99 to +20.99 mA 0.01mA 0.2% or reading + 5counts

Measure 10-50mA -21 to -99.9 mA;+21 to +99.9 mA

0.1mA 1% or reading +5 counts

Dimensions & weight 59 x 38 x 212 mm; 260g

400°C contact temperature with standard K-type thermocouple

Backlit display shows actual and Min/Max measurements with display hold

function

Complies with IEC 61010-1, IEC 61010-2-032 CAT III 600V

Standards: IEC 61010 - 1, CAT III 300V PollutionDegree 2

Supplied with: Carry case and test leads.

One push calibration for DC(A)

Relative Measurement

Supplied with: Carry case, test leads, battery and iinstruction manual

Stock no. Price per OM S$ S$ S$

287-642S unit 1+ 886·00

AC Current 0-600.0A±2.0 5dgt (50/60Hz)±3.5 5dgt (40∼500Hz)

Continuity Check Buzzer Sounds at 100Ω

DC Current 0-600.0A±1.5 ±5dgt

Conductor Size ∅33mm max.

AC Voltage 6/60/600VAuto Ranging±1.5 ±4dgt (50/60Hz)±3.5 ±5dgt (40∼400Hz)

Withstand Voltage 6880V AC for 5 seconds

DC Voltage 600m/6/60/600VAuto Ranging±1.0 ±3dgt

Dimensions 243(L) × 77(W) × 36(D)mm

Resistance 600/6k/60k/600k/6M/60MΩ (Auto Ranging)±1 ±5dgt (600-6M) / ±5 ±8dgt (60M)

Weight 300g

Frequency/Duty 10/100/1k/10kHz (Auto Ranging) / 0.1∼99.9%

Measurement Ranges AC Current equals +/- 2% rdg +/- 5 digits(50 - 60 Hz)

DC Current 0 to +/- 100 A Power Source R03 (AAA) x 2 AC Current 0 to 100A Dimensions (mm) 161.3 (L) 40.2 (W) 30.3 (D) Accuracy Weight 110g (with batteries) DC Current equals +/- 2% rdg +/-5 digits

Supplied with: 2 AA alkaline batteries, 1 pair TL75 test leads, 80BK integrated DMM

Temperature probe, users manual, soft carrying case.

Contact RS for calibration requirements

Stock no. Price per OM S$ S$ S$

255-023 unit 1+ 425·00

Stock no. Price per OM S$ S$ S$

466-6042 unit 1+ 205·00

Function Measurement ranges Accuracy

DC Voltage 40V, 400V, 600V ± (1% reading + 5 digits)

AC Voltage 40V, 400V, 600V ± (1.5% reading + 5 digits) 50-60Hz, CF<3

± (3.5% reading + 5 digits) 40Hz-1kHz

DC Current 400A, 1000A ± (1% reading + 5 digits)

AC Current 400A, 1000A ± (1.5% reading + 5 digits) 50-60Hz, CF<3

± (3.5% reading + 5 digits) 40Hz-1kHz

Frequency 3000 Hz ± (1.5% reading + 5 digits)

Resistance 400Ω, 4000Ω ± (1% reading + 5 digits)

Continuity buzzer Sounds at <20Ω on 400Ω range

Conductor size, AC/DC current Maximum 33mm Ø

Withstand voltage 5550Vac for 1 minute

Power Source 6F22 or equivalent (PP3 9V) battery

Size (LxWxD) and Weight 208 x 91 x 40 mm, approx. 450 g

Contact RS for calibration requirements

Stock no. Price per OM S$ S$ S$

543-289 unit 1+ 475·00

Range Accuracy Resolution

Volts DC 0 to 600V ±(1% + 5d) 0.1V

Volts AC 0 to 600V ±(1% + 5d) 0.1V

Current AC 0 to 600A ±(2% + 5d) 0.1A

Current DC 0 to 200μA ±(1% + 5d) 0.1μA

Resistance 0 to 9999Ω ±(1.5% + 5d) 0.1Ω

Temperature -10 → +400 °C ±(1% + 0.8°C) 0.1°C

Capacitance 1μF to 1000μF ±(1.9% + 2d) 0.1μF

Continuity ≤30 Ω

Maximum jaw capacity 30mm

Dimensions & weight 280 x 80 x 40 mm, 310g

Note: Image shows DCM400AD only, DCM400 is similar

Stock no. Price per OM S$ S$ S$

131-303S unit 1+ 450·00

DCM 400 DCM 400 AD

AC (A) 40/400 A 40/400 A

DC (A) – 40/400 A

AC (V) 400/600 A 400/600 V

DC (V) 400/600 V 400/600 V

Frequency (A) 20-4k/10kHz –

Frequency (V) 4k/40k/400k/4M/10MHz –

Resistance (Ω) 400Ω 400Ω

Clamp Diameter 25 25

Manu. Part No. Stock no. Price per OM S$ S$ S$

DCM400 353-3957 unit 1+ 175·50

DCM400AD 353-3963 unit 1+ 300·00

2256

www.nguyenxuong.com

Page 22: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Power Clamp Meters

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Visit our website for additional price information and exciting promotions

ISO-TECH 6600 Power Clamp

ISO-TECH IPM2009R

ISO-TECH IPM3000N HVACPower Clamp Meter

ISO-TECH IPM138 HVAC AC/DC Power Clamp Meter

Amprobe ACD-14 TRMS FX

3¾ digit 4000 count LCD with fast analogue bar graph

The IPM3000N is a 1000Aac power meter with features ideally suited to HVAC and

electrical maintenance applications.

The ACD 14 FX is the professionals’ choice for both HVAC &

Electrical applications due to its complete set of measuring

A power clampmeter designed to meet the BSEN61010 &

The IPM138 is a 600A ac/dc power meter with features ideally suited to HVAC and

electrical maintenance applications.

True rms reading

AC+DC 1200KW power measurement

DC/AC 2000A current measurement with analogue output

Large 55mm jaw capacity (bus bars to 64mm x 25mm)

600Vac/dc voltage measurement

Type K thermocouple input. Type K adaptor (available separately) accepts

thermocouple sensors with miniature connectors

Continuity buzzer up to 40Ω

Auto-ranging A, V,°C & KW

Relative measurement

Display min/max. hold

Powered by 1x alkaline PP3 battery (supplied)

100MΩ resistance range

Safety to EN 61010-1 CAT III 600V

BS61010-2-032 600V cat III

features. Its dual display allows voltage and current to be viewed simultaneously, and

the True RMS capability gives accurate and reliable measurements.

10,000 count dual display LCD

True rms current & voltage measurement

True and apparent power and phase angle measurement (kW, kVA, Ø)

Dual display options (kW+PF, kVA+ Ø,V+A, A+Hz, V+Hz)

1000Aac current range to check motor & compressor current consumption

40mm clamp diameter

Min/Max with elapsed time to capture motor inrush current readings

Data hold facility

1nF to 3500μF capacitance range suits run/start capacitor checks

1kHz frequency measurement range

Diode and continuity test

μA range to measure flame sensor current

6000 count large backlit LCD display

True RMS current & voltage measurement AC + DC coupled

1000V ac/dc voltage measurement

600A ac/dc current measurement

600kW active power measurement and PF display

Total Harmonic Distortion measurement

AC current inrush measurement ideal for motor & compressor checks

MIN/MAX, Display and PEAK hold

20kΩ resistance measurement.

-50 °C to 1000 °C type K thermocouple temperature measurement input & sensor

4kHz frequency counter

Continuity & diode testAC/DC power factor measurement

AC/DC voltage measurement

AC/DC current measurement

3 phase AC/DC balanced & unbalanced

Apparent power & reactive power

Phase angle

Frequency measurement

10,000 count 4-digit dual LCD display

Powered by 9V alkaline PP3 battery (supplied)

Dual 33⁄4 digit 4000 count displays

True RMS reading, Auto-ranging

Current and Voltage can be read simultaneously

AC and DC Voltage to 600V

AC Current to 400A

Resistance to 40MΩ with Continuity Buzzer

Micro-amp measurements for testing “Flame Sensors”

Temperature reading via Type-K thermocouple probe

Capacitance to 3000 μF

Frequency measurement

Diode test

Hold and Maximum reading functions

Auto power-off and low battery indication

Accommodates conductors up to 1.02" (26mm) in diameter

Rubber over-moulded case

100MΩ resistance range

Size (HxWxD) and weight: 228x76x39mm, 465g

Meets with EN61010-1 IEC1010-2-032 600V Cat III

900°C range Type K thermocouple input socket.

Analyse time-stamped temperature and power data

Supplied with: test leads, 9V PP3 battery

35mm conductor jaw size

Complies with IEC 61010-1 CAT III 600V, CAT II 1000V

Supplied with: case, battery & instructions

Supplied with: Test leads, 2 x croc clips, case, 9V PP3 battery,7 instructions

Supplied with: Test leads, carry case, type K thermocouple probe & battery

Safety EN 61010-1 Accuracy dc current ±(1.5% + 3 digits) Power measurements 40; 400; 1200 KW Maximum ac voltage (V) 600 Temperature measurement(°C)

-50 to 400; 400 to 1000 Resolution ac voltage (V) 0.001 (4 V); 0.01 (40 V); 0.1(400 V); 1 (600 V)

Maximum ac current (A) 2100 Accuracy ac voltage ±(1.5% + 3 digits) Resolution ac current (A) 0.1 (400 A); 1 (2100 A) Maximum dc voltage (V) 600 Accuracy ac current ±(2.5% + 5 digits) Accuracy dc voltage ±(1.5% + 3 digits) Maximum dc current (A) 2500 Maximum jaw capacity (mm) 55; 64 x 25 Resolution dc current (A) 0.1 (400 A); 1 (2500 A) Size (HxWxD) and Weight 271 x 112 x 26mm, 647g

Supplied with: PP3 9V battery, carry case, test leads, type K thermocouple adaptor and type K bead

sensor, users manual, vinyl belt pouch.

Measurement Range Accuracy

DC Voltage 1000V ±(0.7% +5d)

AC Voltage (45Hz ∼ 500Hz) 1000V ±(1.0% +5d)

DC Current 600A ±(1.5% +5d)

AC Current 600A ±(1.5% +5d) 45Hz ∼ 65Hz ±(2.5% +5d) 6Hz ∼ 500Hz

Power measurement (kW) 600kW Sum of voltage & current errors

Power Factor PF -1 to +1 ± 3°

THD measurement (Fundamental 45 – 65Hz)

0 ∼100% ±(3% +10d)

Inrush Current (Integration time ∼100ms)

10.0 ∼ 59.9Aac 60.0 ∼ 600A

±(2.5% +2A) ±(2.5% +5d)

Temperature measurement -50 to +1000°C ±(1% +3°C)

Dimensions & weight 235mm x 78mm x 41mm 400g

Safety BSEN 61010; BS 61010-2-032 Accuracy dc current (A,mA)

± 2.5% ± 5 digits (50 / 60 Hz); ± 3%± 5 digits (40 - 400 Hz)

Memory (Test results) Yes Maximum ac voltage (V) 600V (ac + dc, Trms) Phase angle accuracy(%)

± 2 Resolution ac voltage (V) 0.1 (0 - 200 V); 0.1 (200 - 500 V); 1(500 - 600 V)

Maximum ac current (A) 2000A (ac + dc, Trms) Accuracy ac voltage ± 1.5% ± 5 digits (50 / 60 Hz); ±2.0% ± 5 digits (40 - 400 Hz)

Resolution ac current (A) 0.1 (0 - 200 A); 0.1 (200 - 500 A); 1(500 - 2000 A)

Maximum dc voltage (V) 600V (ac + dc, Trms)

Accuracy ac current ± 2.5% ± 5 digits (50 / 60 Hz); ± 3%± 5 digits (40 - 400 Hz)

Accuracy dc voltage ± 1.5% ± 5 digits (50 / 60 Hz); ±2.0% ± 5 digits (40 - 400 Hz)

Maximum dc current (A,mA)

2000 A (ac + dc, Trms) Maximum jaw capacity(mm)

55 dia. or 65 x 24 bus bar

Resolution dc current (A,mA)

0.1 A (0 - 200 A); 0.1 A (200 - 500A); 1 A (500 - 2000 A)

Size (HxWxD) andWeight

271 x 112 x 46mm, 647g

Stock no. Price per OM S$ S$ S$

697-3733 unit 1+ 580·00

Standards: CE, CAT III 600V

Function Measuring Ranges Basic accuracy Range resolution

Power measurement 60 → 600 kW/kVA ±5% 10 → 100 W/VA

Phase angle -60° → +60° ± 6° 0.1°

DC Voltage 999.9 mV → 600 V ±1.0% 100 μV → 0.1 V

AC Voltage 999.9 mV → 600 V ±2.0% 100 μV → 0.1 V

μA (AC+DC) Current 99.99 μA → 999.9 μA ±1.0% 10 nA → 100 nA

AC Current 99.99 mA → 999.9 A ±2.0% 10 mA → 1 A

Resistance 999.9 Ω → 99.9 MΩ ±1.0% 100 mΩ → 10 kΩ

Capacitance 10 μF → 7000 μF ±1.5% 1 nF→ 1 μF

Frequency 40 Hz → 1kHz ±0.5% 0.01Hz

AC V 4.000V/40.00V/400.0V/600 V Accuracy: ±(1.5% Rdg + 5 digits)

DC V 0-400.0 mV/4.000V/40.00V/400.0V/600V Accuracy: ±(0.5% Rdg + 3 digits )

AC A 0-40.00A/400.0A Accuracy: ±(1.9% Rdg + 8 digits)

AC/DC microamps 400μA/2000μA Accuracy: DC: ±(1.5% Rdg + 4 digits), AC: ±(2.0% Rdg + 5 digits)

Resistance 0-400.0 Ω/4.000 kΩ/40.00 kΩ/400.0 kΩ Accuracy: ±(0.6% Rdg + 4 digits)

Capacitance 500.0nF/5.000μF/50.00μF/500.0μF/3000μF Accuracy:±(3.5% Rdg + 6 digits)

Frequency 10Hz to 100kHz Accuracy: ±(0.5% Rdg + 4 digits)

Temperature -4°F to 572°F (-20°C to 300°C) Accuracy: ±(2.0% Rdg + 6°F)

Conductor Size 26mm diameter max.

Size (LxWxH) and Weight 190 x 63 x 32mm, 204g

Stock no. Price per OM S$ S$ S$

697-4067 unit 1+ 260·00

Stock no. Price per OM S$ S$ S$

697-3780 unit 1+ 750·00

Accessories

Stock no. Price per OM S$ S$ S$

697-3746 unit 1+ 260·00

Type Clamp Multimeter Maximum Voltage 600 VCurrent Type AC Max. Conductor Size 26 mmMaximum Current 400 A

Description Stock no. Price per OM S$ S$ S$

Thermocouple AdaptorKDMM I/P

222-0234 unit 1+ 15·50

Stock no. Price per OM S$ S$ S$

543-885 unit 1+ 167·50

2257

www.nguyenxuong.com

Page 23: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Power Quality Analysers

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple a New product to range

Fluke 43B Power Quality Analyser

Fluke 434/PWR Power Analyser Kit

Fluke 434 & 435 3 Phase Power QualityAnalysers (3U+I)

Fluke 1735 Power Logger

Voltage, current and power harmonics to the 51st, phase angle and THD

Sag and swell measurement down to one cycle, recorded over time

Voltage, current and frequency measurement, and waveform display

Power measurements - watts, power factor, displacement power factor, VA

and Var

Complete three-phase

troubleshooting tool for finding

energy waste in commercial and

factory buildings and equipment.

Number of inputs: 4 voltage and

current (3 phases + neutral).

Maximum input voltage: 1000 Vrms

(6 kV peak).

Maximum sampling speed: 200 kS/s

on each channel simultaneously.

Vrms (AC+DC): 1 … 1000 V.

20 measurement memory to save/recall screens and data with cursor readings

Captures up to 40 voltage transients

Ohms, continuity and capacitance measurement

Temperature scaling for temperature accessories

Calculates 3-phase power on balanced loads

The Fluke 1735 Power Logger is the ideal

tool for electricians and maintenance

technicians for conducting energy studies

and basic power quality logging. The 1735

Contact RS for calibration requirements

Note: VPS40 Voltage Probe and 61 IR Thermometer are not included as this

product not is sourced from Europe

Volt/Amps/Hertz.

Dips and swells.

Power and energy: Watt, VA, VAR, kWh, kVAh, kVARh, Power Factor / Cos / DPF.

Unbalance, Harmonics. & inter-harmonics

Autotrend recording: Up to 450 days.

Memory - Screens and Data: 50, shared memory divided between logging, screens and data sets

Fluke power quality analysers help locate,

predict, prevent and troubleshoot problems in

power distribution systems and include many

features to capture details to pinpoint problems

quickly and safely. Troubleshooting is fast with

on-screen display of trends and captured events,

logs most electrical power parameters, harmonics and

captures voltage events. View graphs and generate reports

with the included Fluke Power Log software.

Supplied with: Rugged soft carry case, i430-Flexipack 4 current clamps, 5 Test leads, BC430 Battery

charger eliminator, Power Log Software, OC4USB Optical cable for USB, Colour localization set, user

manual pn CD-ROM

3 Phase power meter and data logger in one instrument

ideal for troubleshooting, load profiling and supply

monitoring

even while background recording continues.

Confirm instrument setup easily with colour display of waveforms and trends

Record power and associated parameters for up to 45 days with built in 4MB flash memory, 3.5MB

for measuring data

Measures all three phases and neutral with 4 flexible 3000A ac current probes (supplied)

Numerical display of RMS values of current and voltage, plus frequency and related parameters

High resolution colour transmissive ¼VGA display (320 x 240) for waveform, harmonics, chart and

multi parameter display

Prove the benefit of efficiency improvements with power & energy consumption tests in single or

three phase systems, star or delta configuration

Measure harmonic distortion caused by electronic loads for voltage and current up to the 50th

Identify system power characteristics with internal trend recording with real time clock for RMS

values of voltage and current, power & energy

Improve reliability by capturing voltage dips and swells from load switching

Monitor maximum power demand over user-defined averaging periods

Automatic recording of min., max., average values (1⁄2 cycle values)

On screen analysis or data download via RS-232 for reporting and archiving of results

NiMH rechargeable battery giving typically 12 hours operation or mains powered for continuous

use

No. Phases 4Maximum Voltage 1000 Vrms

Complete three-phase troubleshooting tool: measures voltage,

current, frequency, power, unbalance and flicker, harmonics, inter

harmonics, power consumption (Energy) and inrush

AutoTrend: Every displayed reading is automatically and

continuously recorded without having to set up threshold levels or

interval times

Displays trends in voltage, current, frequency, power, harmonics or

Description Stock no. Price per OM S$ S$ S$

Fluke 434/PWR 705-1272Sa unit 1+ 9321·00

Standards: IEC 61010-1, 600V CATIII, Pollution degree 2

Supplied with i400s ac current clamp (4 supplied) range 0.5A to 400A; , maximum conductor

diameter 32mm. Safety rating CAT IV, 600V

flicker on all three phases plus neutral

Analyse the trends using the cursors and zoom function while background recording continues

System-Monitor: gives immediate insight into power system’s quality. Checks conformity to limits

specified in EN50160 or to user defined limits. The overview is shown on a single screen, with

colour-coded bars clearly indicating which parameters fall outside the limits

Inrush mode for troubleshooting nuisance circuit breaker tripping

Four channels: simultaneously measures voltage and current on all three phases and neutral

Meets EN61010-1 600 V CAT IV, 1000 V CAT III safety standard required for measurements at the

service entrance.

Rugged, handheld instrument operates for more than 7 hours on included rechargeable NiMH

battery pack

Complies with IEC 61000-4-30 measurement standards.

Stored measurements can be transferred to a PC to view graphs and generate reports with

FlukeView software with OC4USB interface adaptor / cable (supplied)

Automatic transient display: captures up to 40 dips, swells, interruptions or transients automatically

8MByte memory, shared memory divided between logging, screens and datasets

Fluke 435 Advanced Features

Supplied with: Soft carrying case, 4 flexible current probes (15A/150A/3000 A), Power Log software,

Voltage leads and clips, Colour localisation set, RS-232 PC interface cable, (9 way) mains adaptor.

Fully Class A Compliant - conduct tests according to the stringent international IEC 61000-4-30 Class

A standard

Configure for any test condition with memory for over 400 parameters at user defined intervals

16MByte memory, shared memory divided between logging, screens and datasets

Measure interference from specific frequency signals with mains signalling function

i430 flexible current clamp (4 supplied as standard) range 30A to 3000A ac; , maximum conductor

diameter 160mm. Safety rating CAT IV, 600V

C435, Hard carrying case with handle and wheels

PowerLog software

Volts rms V-rms (STAR) measurement ranges:57V/ 66V/ 110V/ 120V/ 127V /220V/ 23 V/ 240V/ 260V/ 277V/ 347V/ 380V/ 400V/417V/ 480V acV-rms (DELTA) measurement ranges:100V/ 115V/ 190V/ 208V/ 220V/ 380V/ 400V/ 415V/ 450V/ 480V/ 600V/ 660V/ 690V/720V/ 830V ac

Amps rms Flexi set measurement range: 15A/ 150A/ 3000A rms (at sine)Current clamp measurement range: 1A/ 10A

Frequency Measurement range: 46 Hz to 54 Hz and 56 Hz to 64 Hz

Harmonics and THD To 50th harmonic (< 50 % of nom)

Power measurementMeasuring range(P - Active, S - Apparent, Q- Reactive, D - Distorting)

see V-rms and A-rms measurement ranges

Energy Measurement (kWh,KVAh, kVARh)

1 W to 10 W resolution

PF (Power factor) 0.000 to 1.000

Events Detection of voltage dips, voltage swells and voltage interruptions with a 10msresolution and measuring error of the half period sine wave of rms

Memory 4 MB Flash memory, 3.5 MB for measuring data

Sample rate 10.24 kHz

Line frequency 50 Hz or 60 Hz, user-selectable, with automatic synchronization

Display VGA Graphic Color transmissive displays 320 x 240 pixels with additionalbackground lighting and adjustable contrast, text and graphics in color

Interface RS-232 SUB-D socket; 115.2 k Baud

Power supply NiMH battery-pack, with ac adapter (15V to 20V / 0.8A)

Operating temperature 0 °C → +40 °C

Size (HxWxD) 240 mm x 180 mm x 110 mm

Weight 1.7 kg, including battery

Current Clamp Options

Stock no. Price per OM S$ S$ S$

636-2809 unit 1+ 4934·00

i430Flex 3000A ac flexible current clamps (set of 4 supplied as standard with 435) range 30A to

3000A, maximum conductor diameter 160mm. Safety rating EN610101 CAT IV, 600V

i5sPQ3: 5Aac current clamps (3 in a set) range 10mA to 5A; maximum conductor diameter 15mm,

Safety rating EN610101 CAT III 600V

i1000s, ac current clamp (sold individually) range 0.1A to 1000 A rms, maximum conductor

diameter 54mm. Safety rating EN610101 CAT III 600V

Contact RS for calibration requirements

Note: 3 year warranty on Analyser units 434 & 435 only.

Supplied with: Hard carrying case (Fluke 434 with C434, Fluke 435 with C435 with handle and

wheels), 4 current probes, 5 test leads and crocodile clips, NiMH battery charger, BP190 NiMH

rechargeable battery (installed), FlukeView analysis (Fluke 434 and 435) & PowerLog software (Fluke

435 only), OC4USB optical USB cable, colour localisation set, quick start printed manual, user manual

CD.

Range Accuracy

Voltage Vrms (AC+DC) 1 to 1000V ±0.1% of nominal (FL435) ±0.5% of nominal (FL434)

Current Arms (AC+DC) 0 to 20000A ±0.5% ± 5 counts Frequency 42.50 57.50 Hz ±0.01% Harmonics DC, 1 – 50 (Off, 1 – 49) Power Watt,VA,VAR 1.0 – 20MVA ±1.0% ± 10 counts Energy * kWh,kVAh,kVARh 0.00 – 200.0 GVAh ±1.5% ± 10 counts Power Factor 0 - 1 ±0.03 Flicker Pst(1min),Pst,Plt,PF5 0.00 – 20.00 ±5% Unbalance Volts 0.0 – 5.0% ±0.15% Unbalance Current 0.0 – 20% ±1% Transient capture ±6000V ±2.5% of Vrms Min transient capture time 5μs Inrush Arms (AC+DC) 0.00 – 20.00 kA ±1% of measurement ± 5 counts Memory - Capacity 8MByte (FL434)

16MByte (FL435) Shared memory divided between logging, screens and datasets

Memory - Screens/Data 50/10 Standards Measurement method: IEC61000-4-30 Class A;EN50160;IEC61000-4; IEC61000-4-7 Battery life 7hours; 4 hour typical charging time Size (HxWxD) and Weight 256 x 169 x 64mm, 2kg

Description Stock no. Price per OM S$ S$ S$

Fluke 435 613-1576 unit 1+ 13940·00

Fluke 434 493-5506a unit 1+ 10363·00

Accessories

Description Stock no. Price per OM S$

I5sPQ3 Clamp set of 3 530-0995a 1 set 1+ 2078·00

i1000s Clamp 408-8751a unit 1+ 937·00

2258

www.nguyenxuong.com

Page 24: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

New products available online every week

ISO-TECH IPM3005 3000Aac,Flexible Probe PowerQuality Tester

Fluke 345 Power Quality Clamp Meter

CA8220 Power Analyser

Balanced 3 phase and single phase 3000A power quality tester with

flexible 3000A probe and data logging functions for the

measurement and diagnosis of power problems in electrical

installations and power circuits. An optically isolated USB lead and

analysis software enables readings to be displayed and/or

downloaded for analysis on a PC or Laptop.

The Fluke 345 measures a wide range of electrical parameters for troubleshooting

The CA8220 is optimised for maintenance and

troubleshooting of electrical equipment, electrical systems

and in single phase and balance three phase systems.,The

CA8220 includes measurements for testing and monitoring

rotating machines in operation. including temperature,

current , duration of in-rush current, resistance of windings

and rotation speed.

power disturbances in single- and three phase electrical loads. With a bright colour

display to see waveforms and trends, a low-pass filter to remove high frequency noise,

and a high EMC immunity design, the Fluke 345 is ideal for measurements on

switching loads such as variable speed drives, electronic lighting and UPS systems.

True RMS measurement of Vac and Iac

Active power measurement (W, kW, HP)

Reactive power measurement (VAR, kVAR)

Apparent power measurement (VA, kVA)

Power factor (PF) and phase angle (Ø) measurements

Energy calculation (WH and kWH)

Measures balanced 3Ø power and sequence

Clamp-on measurement of ac current up to 1400A rms and dc current up to 2000A

without breaking the circuit

Low pass filter ensures the clamp meter is accurate in noisy environments even with

distorted waveforms present on electronic loads

Identify intermittent faults by logging any power quality parameter for minutes, or

over a month, including harmonics

Direct measurement of dc ripple (%) for battery and dc systems

Analyse and log harmonics digitally or graphically

Inrush current measurement to capture and analyse nuisance tripping, from 3 to 300

seconds

Large backlit 173-segment LCD display.

Power measurement up to 250kW (dependant on clamp selection)

600V rms and up to 6,500A (with clamps)

Harmonics (IEC 1000-4-7) display up to 50th order

MIN, MAX, AVERAGE, PEAK and Crest Factor display

W, VA, VAR power, DF, THD, CosΦ

Inrush current measurements – Max instantaneous value; Max RMS half-

cycle current value and duration of motor start.

RPM rotation speed

Resistance measurement

Simultaneous recording of all parameters, alarms and motor start up

currents.

RS232 direct output to PC

2 wire PT100 temperature probe input

Select AC current probes separately :-

Ampflex A193: 10 to 6500Aac (10Hz to 20kHz) 450mm long flexible probe

(rs 236-565)

MN93A: 0.2 to 120Aac (40Hz to 10kHz): Jaw size 20mm dia. (rs 236-559)

IP54 Rated

Large backlit colour display of waveforms (scope function) and trends

Balanced 3-phase power measurement capability

Power Log software supplied to view graphs and generate reports on a PC

USB interface

Harmonic analysis: Analyse, display and log harmonics up to the 30th harmonic (40th harmonic for

15Hz to 22Hz)

Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems

EN61010 safety rating: 600V CAT IV / 1000V CAT III rated for use at the service entrance

Supplied with: Supplied with 6 off AA alkaline batteries, test leads, 4mm test

Fluke 43B Basic Fluke 43B

Power - 5 W Safety EN/IEC 61010-2-032; ANSI/ISA S82; CSA-C22.2 No.1010.1-92; UL 1244 Power Measurements 250W to 1.56GW Memory (Test results) Yes Phase Measurement Yes Phase Angle Accuracy ±3° to ±15°Power Factor 0 to 1.0 Capacitance Measurement Yes Temperature Measurement -100 to +400 C Maximum ac Current 1250kA (rms, ac + dc) Accuracy ac Current ± (1% +10 Counts) (rms, ac + dc) Maximum dc Current 1250kA (rms, ac + dc) Accuracy dc Current ± (1% +10 Counts) (rms, ac + dc) Maximum ac Voltage 1250V (rms, ac + dc) Accuracy ac Voltage (V, mV) ± (1% +10 Counts) (rms, ac + dc) Maximum dc Voltage 1250V (rms, ac + dc) Accuracy dc Voltage (mV, V, Percent) ± (1% +10 Counts) (rms, ac + dc) Continuity Check Yes Diode Test Yes Size (HxWxD) and Weight 232 x 115 x 50mm, 1.1kg

probes, crocodile clips, RS232/USB optical cable and instructions

Features & facilities

Standard available in all models 43B Basic 43B

Fliuke 43B Power Quality Analyzer YES YES

BP120MH Ni-MH Battery pack (Installed) YES YES

PM 8907 Battery Charger/Line Voltage Adaptor YES YES

TL24 Test Leads YES YES

AC20 Industrial test Clips YES YES

TP4 Slim Reach Test Probes (4mm) YES YES

BB120 Banana-to-BNC Adaptor plug YES YES

Model Difference

i400s AC Current Clamp (400 A) YES YES

SW43W FlukeView Software for Windows + Power Quality Video YES

OCBUSB Interface/Adaptor Cable YES

C120Hard Case YES

TP1 Slim Reach Test Probe Set (flat blade) YES

AC85 Large Jaw Alligator Clips YES

Users Manual / Application Guide (CD-ROM) YES YES

Getting Started Booklet YES YES

VPS40 Voltage Probe YES

Fluke 61 IR Thermometer YES

Supplied with: Test Leads, Power Log software on CD-ROM, USB lead, batteries(fitted), mains

adaptor, carry case & instructions.

Voltage range 6 VRMS to 600 VRMS AC+DC ±(0.5%+2pts) AC current range 5mA to 6500 A ±(0.5%+1pts) DC current range 1 A to 1700 A ±(1%+1pts) Fundamental frequency 40 Hz to 70 Hz Harmonics (IEC 1000-4-7) Up to 50th order Engine rotation speed 6 RPM to 120 kRPM ±(0.5%) Temperature (Pt100) 200°C to 850°C ±(1%+10pts) Resistance (coiling) 0.0Ω to 2000 Ω ±(0.5%+1 Ω) Phase rotation Yes, with display of phase order in three-phase IEC 61010-1 600 V, Cat. III

Current

DC, DC rms, AC rms All measurements dc and 15Hz to 1kHz. Amps rms is a true rms measurement (ac + dc)

Maximum overload 10,000 A or RMS x frequency < 400,000 Harmonics All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequency range

F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A Measuring range 0 – 2000 A dc or 1400 ac rms Accuracy DC, rms I > 10 A: ± 1.5 % rdg ± 5 digits

I < 10 A: ± 0.2 A Voltage measurement

DC, DC rms, AC rms All measurements dc and 15 Hz to 1 kHz. Volts rms is a true-rms measurement (AC + DC)

Maximum overload 1,000 V rms. Measuring range 0 – 825 V dc or ac rms Accuracy DC, rms V > 1 V: ± 1 % rdg ± 5 digits

V < 1 V: ± 0.02 V Harmonics All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hz to 65

Hz; Vacrms > 1V Power (single and three phase)

Watts measurement 0 – 1650 kW dc or 1200 kW DC, DC rms, AC rms Accuracy 2.5 % rdg ± 5 digits

W1Ø < 2 kW ± 0.08 kWW3Ø < 4 kW ± 0.25 kW

VA measurement 0 -1650 kVA dc or 1200 kVA ac DC, DC rms, AC rms Accuracy VA > 2 kVA: 2.5 % rdg ± 5 digits

VA < 2 kVA: ± 0.08 kVA VAR measurement (0.3 < PF< 0.99)

0 – 1250 kVAR

Accuracy VAR > 4 kVAR: ± 2.5 % rdg ± 5 digitsVAR < 4 kVAR: ± 0.25 kVAR

Power factor &Displacement power factor

0.3 capacitive to 1.0 to 0.3 inductive (72.5° capacitive to 0° to 72.5° inductive)

Kilowatt Hour (kWHr) 40,000 kWHr Accuracy kWHr > 2 kWHr: ± 3 % ± 5 digits

kWHr < 2 kWHr: ± 0.08 kWHr Frequency Measurement

Accuracy 15 to 22 Hz ± 0.5 % rdg40 Hz to 70 Hz ± 0.5 % rdg15 Hz to 1000 Hz ± 1% rdg

Scope function

Time base 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div Current measurement: Ranges 10A/ 20A/ 40A/ 100A/ 200A/ 400A/ 1000A/ 2000A Accuracy ± 3 % rdg ± 1 pixel Voltage measurement: Ranges 4V/ 10V/ 20V/ 40V/ 100V/ 200V/ 400V/ 1000V Accuracy ± 2 % rdg ± 1 pixel Inrush current function All measurements dc and 15 Hz to 1 kHz Ranges 40, 400 and 2000 A Memory Up to 50 screen shots and over 150,000 individual measurement values Safety IEC 61010-1 600 V CAT IV, 1000V CAT III Display Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight Jaw opening 60 mm, max conductor 58 mm diameter Battery type 6 off 1.5 V Alkaline AA MN 1500 or IEC LR6 Battery Eliminator BE345 Input 110/230 V 50/60 Hz

Output 15 V dc, 300 mA

Description Stock no. Price per OM S$ S$ S$

Fluke 43B 413-0004 unit 1+ 6072·00

Stock no. Price per OM S$ S$ S$

252-214S unit 1+ 3973·00

Stock no. Price per OM S$ S$ S$

237-394 unit 1+ 930·00

2259

www.nguyenxuong.com

Page 25: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple a New product to range

Accessories for Fluke 430 Series

ISO-TECH IPM6300 3000A acGraphical Power QualityAnalyser

ISO-TECH IPM6200 1500A acPower Quality AnalyserA single phase and balanced 3 phase 1500A ac graphical power quality analyser

with data logging functions for analysis and diagnosis of power quality & power

disturbance problems in electrical installations and power circuits. Optically isolated

USB connection lead & analysis software is supplied enabling readings to be

displayed and recorded data to be downloaded controlled and analysed on a PC or

laptop computer.

Balanced 3 phase and single phase 3000A graphical power

quality analyser with data logging functions for the analysis

and diagnosis of power quality and disturbance problems in

electrical installations and power circuits. An optically

isolated USB lead and analysis software enables readings to

be displayed and/or downloaded for analysis on a PC or

Laptop.

OC4USB: Optical USB interface

cable

BC430: Battery charger/mains

Power quality analysis of single and balanced 3-phase

systems

Graphical display of voltage and current waveforms

Active power measurement (W, kW, HP)

Reactive power measurement (VAR, kVAR)

Apparent power measurement (VA, kVA)

Power factor (PF) and phase angle (Ø) measurements

Power quality analysis of single and balanced 3-phase systems

Graphical display of voltage and current waveforms

128x64 Dot matrix LCD with backlight

Active power measurement (W, kW, HP)

Reactive power measurement (VAR, kVAR)

Apparent power measurement (VA, kVA)

Power factor (PF) and phase angle (Ø) measurements

Energy calculation (WH and kWH)

adapter

Flexible AC current clamps: Set of 4x i2000flex

flexible AC current clamps (2000 A)

WC100 colour localisation set: 32 metal clips for

identifying cables (8 colours)

Non-interrupted harmonic analysis (V and A) to the 50th order in % and magnitude

Dual display with fast Peak Hold, Max and Min functions

Selectable CT ratios from 1 to 1000

Data logging to internal memory for up to 8000 readings with programmable logging interval

Selectable Auto power-off up to 30 minutes

Energy calculation (WH and kWH)

Transient detection of Swell, Dip and Outage

Graphical harmonic analysis (V and A) to the 50th order in % and magnitude

Analysis of % THD

Graphical phase diagram display, plus fast peak display

Maximum demand measurement over presettable time period

128x64 Dot matrix LCD with backlight

Real time clock

Programmable CT ratio from 1 to 3000 for very high power measurements

Data logging to internal memory for up to 50000 readings/32000 transient events with

programmable logging interval

Programming logging interval from 1 to 3000 seconds

Maximum demand measurement over presettable time period

Transient detection of Swell, Dip and Outage

Analysis of % THD

Graphical phase diagram display, plus fast peak display

Graphical harmonic analysis (V and A) to the 50th order in % and magnitude

Real time clock

Programmable CT ratio from 1 to 3000 for very high power measurements

Data logging to internal memory for up to 50000 readings/32000 transient events with

programmable logging interval

Programming logging interval from 1 to 3000 seconds

Type Stock no. Price per OM S$ S$ S$

OC4USB cable 493-5540a unit 1+ 307·00

Note: Colour may differ from that shown.

Note: Support Accessories: Portable thermal dot matrix printers for results printout, see stock no. 697-

3787

Note: Colour may differ from that shown.

Note: Support Accessories: Portable thermal dot matrix printers for results printout, see stock no. 697-

3787

Supplied with: Opto-isolated USB lead, PC software on CD, Test leads with crocodile clips, Software

and User manuals, 2 x AA alkaline batteries

Note: Support Accessories: Portable thermal dot matrix printers for results printout, see stock no. 697-

3787

ac Current Range 50-60Hz True RMS, Crest Factor 4 0-3000A Resolution ac current 0.1A (0-999.9A), 1A (1000-3000A) Accuracy ac current ±1% of range (typical) ac Voltage Range 50-60Hz True RMS, Crest Factor <4 4-600V Resolution ac voltage 0.1V Accuracy ac voltage ±0.5% reading ±5 digits Power measurement 10W - 9999kW/kVA/kVAR Resolution power 0.1 (10W - 1kW/VA/VAR)

1 (1kW - 10kW/VA/VAR)10 (10kW - 100kW/VA/VAR)100 (100kW - 1000kW/VA/VAR1000 (1000kW - 9999kW/VA/VAR)

Accuracy active/apparent power (0-1500A) ±1% ±20 digits (>20V,>20A)±2% ±40 digits (<20V,<20A)

Accuracy reactive power (0-1500A) ±1% ±20 digits (>20V,>20A)±3% ±40 digits (<20V,<20A)

Accuracy Power Factor (PF) (0.0-1.0) ±0.04 (>20V,>20A) Harmonics Vac (50/60Hz >80V) ± 2%, 1st- 20th

4% of reading ±2%, 21st- 50th

Harmonics Iac (50/60Hz >20A) ± 2%, 1st- 20th

4% of reading ±2%, 21st- 50th

Phase angle (Ø, V>20V, I >30A) -180° to +180°: ±2°0° to 360°: ±2°

THD-F (50/60Hz, >80V, >20A, 1st to 50th Harmonics) 0 to 20%: ±2%20 to 100% :±6% of reading ±1%

Peak value of Voltage (RMS value >10V) ± 5%, ±30 digitsPeak value of Current (RMS value > 20A) ± 5%, ±30 digitsBattery 2 off AA alkaline Maximum conductor size 170mm

Supplied with: Opto-isolated USB lead, PC software on CD, Test leads with crocodile clips, Software

and User manuals, 2 x AA alkaline batteries

Supplied with: Opto-isolated USB lead, PC software on CD, Test leads with crocodile clips, Software

and User manuals, 2 off AA alkaline batteries

Stock no. Price per OM S$ S$ S$

697-3768 unit 1+ 770·00

Peak value of Current (RMS value > 20A) ± 5%, ±30 digitsBattery 2 off AA alkaline Maximum conductor size 55mm dia, 64x24mm bus bar

ac Current Range 50-60Hz True RMS, Crest Factor <4 4-1500A Resolution ac current 0.01A Accuracy ac current ±1% ± 5 digits ac Voltage Range 50-60Hz True RMS, Crest Factor <4 4-600V Resolution ac voltage 0.1V Accuracy ac voltage ±0.5% reading ±5 digits Power measurement 10W - 9999kW/kVA/kVAR Resolution power 0.1 (10W - 1kW/VA/VAR)

1 (1kW - 10kW/VA/VAR)10 (10kW - 100kW/VA/VAR)100 (100kW - 1000kW/VA/VAR1000 (1000kW - 9999kW/VA/VAR)

Accuracy active/apparent power (0-1500A) ±1% ±20 digits (>20V,>20A)±2% ±40 digits (<20V,<20A)

Accuracy reactive power (0-1500A) ±1% ±20 digits (>20V,>20A)±3% ±40 digits (<20V,<20A)

Accuracy Power Factor (PF) (0.0-1.0) ±0.04 (>20V,>20A) Harmonics Vac (50/60Hz >80V) ± 2%, 1st- 20th

4% of reading ±2%, 21st- 50th

Harmonics Iac (50/60Hz >20A) ± 2%, 1st- 20th

4% of reading ±2%, 21st- 50th

Phase angle (Ø, V>20V, I >30A) -180° to +180°: ±2°0° to 360°: ±2°

THD-F (50/60Hz, >80V, >20A, 1st to 50th Harmonics) 0 to 20%: ±2%20 to 100% :±6% of reading ±1%

Peak value of Voltage (RMS value >10V) ± 5%, ±30 digits

ac Current Range 50-60Hz True RMS, Crest Factor <4 0-3000A Resolution ac current 0.1A (0-999.9A), 1A (1000-3000A) Accuracy ac current ±1% of range (typical) ac Voltage Range 50-60Hz True RMS, Crest Factor <4 4-600V Resolution ac voltage 0.1V Accuracy ac voltage ±0.5% reading ±5 digits Power measurement 10W - 9999kW/kVA/kVAR Resolution power 0.1 (10W - 1kW/VA/VAR)

1 (1kW - 10kW/VA/VAR)10 (10kW - 100kW/VA/VAR)100 (100kW - 1000kW/VA/VAR1000 (1000kW - 9999kW/VA/VAR)

Accuracy active/apparent power (0-1500A) ±1% ±20 digits (>20V,>20A)±2% ±40 digits (<20V,<20A)

Accuracy reactive power (0-1500A) ±1% ±20 digits (>20V,>20A)±3% ±40 digits (<20V,<20A)

Accuracy Power Factor (PF) (0.0-1.0) ±0.04 (>20V,>20A) Harmonics Vac (50/60Hz >80V) ±2%, 1st - 20th

4% of reading ±2%, 21st - 50th

Harmonics Iac (50/60Hz >20A) ±2%, 1st - 20th

4% of reading ±2%, 21st - 50th

Phase angle (Ø, V>20V, I >30A) -180° to +180°: ±2°0° to 360°: ±2°

THD-F (50/60Hz, >80V, >20A, 1st to 50th Harmonics) 0 to 20%: ±2%20 to 100% :±6% of reading ±1%

Peak value of Voltage (RMS value >10V) ± 5%, ±30 digitsPeak value of Current (RMS value > 20A) ± 5%, ±30 digitsBattery 2 off AA alkaline Maximum conductor size 55mm dia, 64x24mm bus bar

Stock no. Price per OM S$ S$ S$

697-3755S unit 1+ 1020·00

Stock no. Price per OM S$ S$ S$

697-3743 unit 1+ 445·00

2260

www.nguyenxuong.com

Page 26: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Energy Monitoring

Kyoritsu Power Measurement

Power Disturbance Recorders

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Many more leading brands from over 2,500 suppliers available online

Hawk 5000 Electricity UsageAnalyser

6300 Compact Power Meter

www.rssingapore.com

Fluke 1710 Single-Phase Voltage QualityRecorder

300XP Thermal Printer

Fast and easy recording of voltage trends, dropouts, and

power quality – pinpoints the root cause of single phase

voltage problems

Easy to use – plus directly into the mains power socket

and capture data

Continuous recording of all values with no gaps – saves

testing time by getting the whole picture and records both

events and voltage

Clear graphical summary of data and quick overview of

key power quality parameters

Min, Max, and Average RMS values (1⁄4 cycle) with time

All necessary Power Measurements : V, A, W, VA,

Var, Wh, VAh, Varh, cos θ, In, Hz

Recording function with "integration time"

selectable from 1 second to 1 hour

The Hawk 5000 offers additional

measuring capabilities over the Hawk

3000, enabling more detailed engineering

information to be gained regarding

Portable thermal dot matrix printer for results

printout from test instruments

Text and graphics printing

Programmable header and footer text

Printing width: 46mm: paper width 57mm

9 pin RS-232C interface plus optically isolated

interface for ISO-TECH instruments

Single print and fixed interval continuous

printing modes (5, 30, 60, 300 seconds)

Size W95 x D135 x H55mm; Weight 440g (with

batteries)

Internal non volatile Memory for non-stop recording up to 10 days

Accepts Removable Compact Flash Memory up to 128MB for non-stop

recording up to 5 years

Supplied with interface software for downloading data to PC via USB

Four wiring configurations : 3 Phase 4 Wires, 3 Phase 3 Wires, single

Phase 3 Wire and 2 Wires

Wide screen with back light Multi-Display system for simultaneous

measurements

Double power supply system : from AC Line and from Alkaline battery

with approx. 7 hours of battery life

Demand function for Energy-Saving measurements

Accessories include test leads, USB cable, mains cord, compact flash

card 32MB, PC software, batteries x 6 and carrying bag

stamp – quickly identifies what happened and when

Actual transient display (>100 μs) with time stamp – identifies power quality issues quickly with

included graphical software

Flicker recording to EN 61000-4-15, individual harmonic and THD values with trends – identifies if

the problem is power quality or equipment related

Statistical analysis of single phase voltage events - reduces analysis time by tracking event

quantities and magnitudes

Includes PowerLog software package for quick download, analysis, and automatic reporting – Save

time by generating power quality reports automatically with pre-set templates

Remote access capability via USB port to an external modem

Supplied with: 8 off AA alkaline batteries,

multinational 12V mains adaptor, thermal paper

roll, configuration software on CD-ROM &

instructions

Standards: IEC61010-1 CAT.III 600V

energy usage.

Supplied with: USB cable, PowerLog software on CD-ROM; universal power cord adapters

Instrument Compatibility

ISO-TECH IPM3005, 6200, 6300 power quality testers ISM490 solar module analyser IBT330 battery capacity tester

RS AVM-09 Anemometer

Agilent 34401A bench multimeter Measurements andparameters

Voltage, Current, Activepower,

Effect of power factor Active power : ±1.0% rdgcos θ= ±0.5 (PF=1)

Apparent power, Reactivepower,

Effective input range 10-110% of Rating range of Vand A

Active energy, Apparentenergy,

Display range Voltage : 5-120% of RatingrangeCurrent : 1-120% of Ratingrange

Apparent energy, *Reactiveenergy,

Integration time for 1/2/5/10/15/20/30 Seconds

Power factor (cos θ) recording function 1/2/5/10/15/20/30/60 Minutes Neutral current, Frequencymeter

Display update period 1 second

Wiring connections 1P 2W, 3P 4W, 3P 3W, 1P3W

Operating temperatureand humidity ranges

0-+50°C, less than 85% RH(wiithout condensation)

Voltage ranges 150.0 / 300.0 / 600.0V AC Storage temperatureand humidity ranges

-20 to+60°C, less than 85%RH(without condensation)

Voltage accuracy ±0.3 % rdg ±0.2 % fs[4565Hz]

Over load protection Voltage : 720V AC rmsCurrent : 600A AC rms (withClampsensor MODEL 8125)

Current ranges 50.00/100.0/200.0/500.0 A AC(with Clamp sensor MODEL8125)

PC communicationInterface

USB

Current accuracy ±0.3 % rdg ±0.2 % fs +Clamp sensor accuracy [at45-65Hz]

CF card Interface Compact flash card (Standard type 32/64/128MB)

Crest factor Voltage : up to 2.5 Current :up to 3.0(with 90% fs or less)

Safety standard IEC61010-1 CAT.III 600V

Frequency meter range 40-70Hz Power supply AC Line : 100-240V±10% (50/60Hz) DC Battery 9V : LR6×6(Battery life approx. 7h)

Frequency meter accuracy ±3dgt Power consumption 10VA (MAX) Active Power accuracy ±0.5 % rdg ±0.2 % fs +

Clamp sensor accuracy [at45-65 Hz]

Dimension 175(L)×120(W)×65(D) mm

Accuracy precondition PF=1, Sine wave, 23°C±5°C Weight Approx. 800g (includingbatteries)

Single or 3 phase power kW, kVA and current

Power factor and phase angle

Total kVAr regardless of phase angle

True rms current measurement (3-phase)

True rms voltage (single phase)

Contact RS for calibration requirements

Single phase frequency

Software supplied with the Hawk 5000 enables configuration, on line monitoring, data collection

and analysis with colour graphics.

Safe simple operation requires no connection to live terminals

Status indicators confirm correct operation and guide user for current transformer placement

Phasing wand can be used to ensure correct phase allocation for the CTs

Pulse measuring capability (2 channel) enables logging from remote meters, or fluid flow meters

System accuracy better than 2% ± 1% of range with supplied current transformers

High data capacity enables monitoring for periods between 7 weeks and 38 weeks (dependant

upon detail and logging parameters selected)

Hawk Reporter Pro tariff analysis software for analysis and presentation of survey results in

detailed format

Operating voltage 70 V to 300 V Flickermeasurement

EN 61000-4-15

Min/Max/Avg RMSvalue

Resolution 0.125 V Number ofrecording channels

1 Phase to Neutral2 Phase/Neutral to Ground

Number of events 175,000 Recording time 1 day to 339 days depending onaverage time from 1 second to 20minutes

Dips/Interruptions Yes Transients Yes (>100μs) Time resolution 5 ms Frequency range 50 Hz ± 1 Hz and 60 Hz ± 1 Hz Voltage resolution 0.125 V Power cord

adapterscompatibility

Australia, Central America, Europe,Ireland, Italy, Japan, Malaysia, NorthAfrica, Singapore, Switzerland, UK, US

Over-voltages Yes Safety categoryrating

CAT II 300 V

Frequency Yes Size 23 x 19.75 x 22.2 cmHarmonicsmeasurement

EN 61000-4-7 (up to 32nd)

Type Thermal Printer Dimensions (W)95 x (D)135 x (H)55 mmInterface RS-232C Weight 440 g

Stock no. Price per OM S$ S$ S$

627-8782 unit 1+ 3060·00

Stock no. Price per OM S$ S$ S$

435-601 unit 1+ 1656·00

Stock no. Price per OM S$ S$ S$

697-3787 unit 1+ 370·00

Note: Optional individual 200A CTs are also available to give improved accuracy when monitoring low

current loads.

Accessories

Supplied with: Hawk reporter Pro software on CD-ROM,carry case,3 x 1000A current transformers, 3

x colour coded CT leads, phase probe, RS-232 cable and operators manual

Description Stock no. Price per OM S$

Thermal Paper Roll 671-5890 unit 10+ 6·70

2261

www.nguyenxuong.com

Page 27: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Seaward Portable Appliance Testers

Safety Testing Software

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple

PrimeTest 300

Safety 1st Xpress

Portable appliance testers are used for periodic testing of appliances in the place where they are used

(as required by Health and Safety legislation) and for regular safety testing of appliances for hire,

repair or re-sale (as required by equipment safety regulations).

Fluke 1735 Power Logger

Fluke 435 Logging Power Quality Analyser

Lightweight battery powered hand-held tester

incorporating all Class I and Class II required

Combines the ease of use of earlier software products with

modern Windows presentation standards such as tree and

tabular view, filtering and drag and drop, to make the most

productive of this type of software on the market. The system

is designed to ensure compliance with Health & Safety

legislation whilst keeping administration costs to a minimum.

Uses database technology to hold a register of equipment, a

history of test results and a forward schedule of testing

requirements. A full template for Portable Appliance Testing

(PAT) is included in the software with the added feature of

test records of any other equipment such as ladders, lifting

tackle, cooling towers, emergency lighting, fire extinguishers,

in fact, any equipment that needs regular test.

The Fluke 435 three-phase power quality analyser helps

users to locate, predict, prevent and troubleshoot problems

in three and single phase power distribution systems.

Troubleshooting is faster with on-screen display of trends

and captured events, even while background recording

continues. The new IEC standards for flicker, harmonics and

power quality are built right in to take the guess work out of

power quality.

The Fluke 1735 Power Logger is the ideal electrician or

technician’s tool for conducting energy studies and basic

power quality logging. The 1735 can be set up in seconds

with the included flexible current probes and color display.

The meter is able to log most of the electrical power

parameters, harmonics and captures voltage events as well.

Troubleshoot real-time: Analyse the trends using the

cursors and zoom tools – even while background

recording continues

Highest safety rating in the industry – 600V Cat IV / 1000V

electrical safety tests.

Bluetooth technology enables the wireless connection of bar code

scanners & label printers allowing connection-free testing and data

transfer directly from the tester to a PC-based record keeping systems at

the touch of a button.

Key Features:

On screen graphic display for each reading

Unique screen presentation for assets - assets can be listed, several to a page with all fields shown

in a neat line format

Unique keyboard interface reduces the dependence on mouse operation

Automatic updating of standard tables on data entry

Use of short codes for key data

Generates unlimited ’reader’ systems from the licensed system

Journal system providing the ability to record events such as visits and an asset journal which

complements the test history

Asset tracking - an automatic journal entry is created when an asset is moved from one location to

another

Adaptable to each clients requirements

Prints straight from the screen

Batch input of test results

Group change facility allowing sweeping of asset register updating selected fields with specified

data

Library of downloaded files

Archiving and retrieval routines

Will accept and convert data from the Safety 1st DOS version/Safety 1st plus DOS/Windows version

Compatible with all popular PAT testers including download PAT testers:- Seaward Supernova,

Europa, 2000, 20001, 2000iee, 1000, 1000X, 1000S, SEN60204; Metrohm MicroPAT+; Robin Smart

PAT 5000 and SmartPAT 5500

CAT III

Automatic transient mode captures 200kHz waveform data on all phases simultaneously – up to

6kV

Measure all three phases and neutral with included 4 current probes

AutoTrend: Every measurement seen is always automatically recorded, without any setup

System-Monitor: Up to seven power quality parameters on one screen according to EN50160

In-rush mode for troubleshooting nuisance circuit breaker tripping

Seven hours operating time per charge on NiMH battery pack

View graphs and generate reports with included analysis software

Fully Class A Compliant - conduct tests according to the stringent international IEC 61000-4-30 Class

A standard

Logger function - Configure for any test condition with memory for over 400 parameters at user

defined intervals

Large white backlit graphics display, plus full alphanumeric keypad

Intuitive and fast user interface

Manual and automatic test modes

Programmable soft keys for customised test routines.

User definable and configurable test sequences

Large memory for storing upto 20000 results and test programs

Download / Upload to software

Records asset location and non-electrical test results with customised

System Requirements: IBM PC compatible with 64MB RAM, Pentium II 350MHz processor and high

speed hard disk, CD-ROM drive, Windows 95/98, Windows supported printer. For multi-user

applications it also requires an NT workstation and local area network supporting Windows.

Supplied on CD-ROM.

Record power and associated parameters for up to 45

days

Monitor maximum power demand over user-defined

averaging periods

screen prompts

Large internal memory facilitates the storage of test results for safety audit and traceability

purposes.

In addition to test results, the tester can also record other details and descriptions of the equipment

under test

Prove the benefit of efficiency improvements with energy consumption tests

Measure harmonic distortion caused by electronic loads

Improve reliability by capturing voltage dips and swells from load switching

Easily confirm instrument setup with color display of waveforms and trends

Measure all three phases and neutral with included 4 flexible current probes

View graphs and generate reports with included Power Log software

Compact, rugged design with IP65 case, 600 V CAT III.

View graphs and generate reports with included analysis software

Note: Not all features are available on all testers. Contact technical helpline for further information

Supplied with:

Stock no. Price per OM S$ S$ S$

423-9448 unit 1+ 1570·00

Supplied with:

Hard carrying case with rollers

4 Flex current probes (i430-flex)

5 Test leads and clips

Battery charger

Optical USB cable

Color localization set

Printed getting started manual

User manual CD

FlukeView software

Power Log software

Associated accessories available separately:

Stock Nos:470-2261, 456-1256, 475-1409, 409-9341, 409-9329, 613-1295, 613-1302, 613-1318, 613-1346,

497-498, 445-3846, 450-5969, 514-4824, 513-7056, 399-634, 513-7090 & 513-7078.

Supplied with: Test lead, mains lead, 110V socket adaptor, USB/Bluetooth adaptor with driver

software on CD-ROM, 6 off rechargeable NiMH AA batteries, mains battery charger, 30-day PATGuard

evaluation disk, reference guide, instruction manual on CD-ROM, carry case.

Soft carrying case

4 flexible current probes (15 A/150 A/3000 A)

Power Log software

Voltage leads and clips

Color localization set

PC interface cable

Universal AC adapter

Printed English manual

Multi-language manual CD

Contact RS for calibration requirements

Earth Bond Test Differential Leakage

Output Current (Load 2) : ± 200mA DC Test Voltage: 230V +10%, -15% Test Voltage (o/c): > 4VDC Maximum Load current: 13A rms Test Duration: Programmable within a

maximum limit Test Duration: Programmable within a

maximum limit Measuring Range: 0.01Ω - 19.99Ω Measurement Range: 0.25 - 19.99mA Operating Error: ±5% + 2 counts Measurement Resolution: 0.01mA Measurement Resolution: 0.01Ω Operating Error: ±5% of rdg +2 digits Pass Value: User defined Pass Value: User defined Insulation Test Touch Leakage

Test Voltages: 500VDC @ 1mA nominal Test Voltage: 230V +10%, -15% Test current: >1mA into 500k.; < 2mA into

s/c Maximum load current: 13A rms

Test Duration: Programmable within amaximum limit

Test Duration: Programmable within amaximum limit

Measurement Range: 0.10 MΩ - 40MΩ Measurement Range: 0.10 - 3.50mA Operating Error: ±5% +2 digits Measurement Resolution: 0.01mA Measurement Resolution: 0.01MΩ (Max) Operating Error: ±10% of rdg +2 digits Pass Value: User defined Pass Value: User defined

Stock no. Price per OM S$ S$ S$

627-5727 unit 1+ 14501·00

Contact RS for calibration requirements

Description Stock no. Price per OM S$ S$ S$

Hawk 5000 436-471 unit 1+ 6150·00

200A ac CT 436-516 unit 1+ 245·00

RCD Test Test Current: 30mA rms sinusoidal Test Voltage: 230V +10 %, -15 % Test Current Accuracy: +10, -0 %

Stock no. Price per OM S$ S$ S$

627-5711 unit 1+ 5508·00

2262

www.nguyenxuong.com

Page 28: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Visit our website for additional price information and exciting promotions

Supernova Xe 240V Computerised PAT

Dual Voltage Computerised PAT

PrimeTest 350 (UK)

The Seaward Supernova XE Portable Appliance

Tester is a powerful, lightweight tool, to assist in

the analysis of the safety of 240V portable

A powerful instrument designed to test 240V

and 110V appliances (from a 240V supply),

incorporating the new industrial design the

Lightweight battery powered PAT tester

incorporating all Class I and Class II required

instrument features a flip down keypad and lead storage,

with full graphics display that offers HELP screens and in

built training guidance, a full QWERTY keypad and softkeys

for instant test selection. Tests can be carries out on both

automatic or manual mode on both 240V and 110V, class 1

and class 11 appliances, including business and IT

equipment.

electrical and electronic equipment. A range of tests are provided,

with innovative features to aid difficult test situations, which allow

testing of a wide variety of equipment.

electrical safety tests.Bluetooth technology enables the wireless connection

of bar code scanners & label printers allowing fast, efficient testing and

results recording.,The PrimeTest 350 can complete alternative leakage test,

250V insulation test (for use when suppressors or other components

prevent a 500V insulation test) and load measurement. During the

protective conductor and touch current tests, the load is measured and

displayed as both a power and current measurement.The PrimeTest 350

PAT tester is a &#146;facilities management tool&#146; because through

data logging and capture, it also records the location of the assets – helping

to meet requirements of health and safety standards.

IEC lead test, safety earth test, earth screen test, earth

continuity test, insulation test, subsititue leakage test,

flash test, touch voltage, load test, leakage test and visual

Stores up to 2400 results including, appliances, location, site,

date and time in non-volatile flash memory

Accurate earth bond and leakage measurement even when

multiple earth paths exist

Full QWERTY keyboard with fast keys

Full graphics display, real-time clock

Connects to PC, barcode reader and printer

Software adjusts the user interface to differing levels of

Large white backlit graphics display & full alphanumeric keypad

Intuitive and fast user interface with manual and automatic test modes

Programmable soft keys for customised test routines.

inspection log

Unique earth bond and leakage test, that means accurate earth bond and leakage measurements

Boot up in less than 3 seconds with a full memory check

1,200 test integral memory, storing the history of appliances with technical notes, storing data by

customer, location and site. Stores test codes by appliance type and name

Automatic test code generation

Automatic or user defined pass/fail settings

Control using the most versatile user interface on the market, featuring ’learn mode’ software that

can adjust the interface to suit users of differing levels of expertise

Real time clock

Remote control earth and insulation test probe with pass/fail indication

Flash memory, that means the end of battery backup

Serial and parallel printer output for bar codes, test certificates and test reports

Test results may be downloaded to a PC running Safety 1st or Safety 1st Plus software

expertise

Auto testcode generation

Fast start-up less than 8 seconds

Superfast download up to 10 times quicker than existing testers

Compatible with the Seaward BrainCell equipment tagging system and Test N’ Tag label printer

Test results may be downloaded to a PC running, PATGuard, Safety 1st or Safety 1st Express

Rechargeable batteries with 4 hour recharge time via charging port eliminates the reliance on

mains supply, reduces downtime between tests and makes the instrument practical and portable to

use anywhere.

User definable pass / fail limits and configurable test sequences

Tests performed: Earth continuity, insulation resistance, substitute leakage, power socket wiring

check, protective earth (PE) conductor current, touch current & RCD trip time.

Memory for storing typically 8500 records

Download / Upload to Seaward PATGuard software (available separately)

Large internal memory facilitates the storage of test results for safety audit and traceability

purposes.

In addition to standard electrical safety tests, test records for items such as fire extinguishers,

emergency lighting & microwave ovens can be created and stored. The records can be

downloaded to PATGuard Software for complete traceability

Software utility supplied to upload Company logos from a PC to the tester to incorporate in test

label printout

Compatible with :

Seaward Test N Tag Elite Bluetooth Printer stock no. 461-076

Seaward bluetooth barcode scanner stock no. 461-098

Seaward PatGuard software stock nos. 613-1295, 613-1302, 613-1318 and 613-1346

Note: Compatible with Test ’N’ Tag printer stock number 456-1256

More associated accessories available separately see

Stock Nos: 497-498, 445-3846, 450-5969, 514-4824, 513-7056, 513-7090 & 513-7078.

Note: Options of instrument with UK power lead, or Aus/Nz lead.

Earth Continuity Output currents into 0.1 0hm 100mA, 4A, 10A, 25A ac

Test voltage 6V rms o/c

Ranges 0-2 Ohms, 0-20 Ohms

Accuracy +/-5% of reading +/-2 digits

Resolution 0.01 Ohms selectable (continuity variable)

Pass range Selectable (continuously variable)

Misc 4-wire measurement, floating earth

Insulation test Measuring range 50K-300M Ohms

Test voltage 250V, 500V, DC (0%, +20%)

Accuracy +/-5% reading +/-2 digits

Resolution 0.01M Ohms (>10M Ohms)

Subsititute Leakage Voltage 40V ac nominal at 230/115V supply

Range 100uA-20mA

Resolution 0.01 mA

Accuracy +/-5% reading +/- 2 digits

Pass range Selectable

Flash test Voltage class I 1500V

Class II 3000V +/-10% at 1mA at 230/115V supply

Load test Voltage measurement 90V-300V

Current 0.16A ms

Leakage Range 100uA-10mA

Resolution 0.01mA

Accuracy +/-5% reading +/-2 digits

Pass range Selectable

IEC lead test Test performed Earth continuity, Insulation

Polarity check Yes

Operating voltage Voltage range 103V - 126V, 207V-253V

Frequency 45Hz-65Hz

Test voltage/currents are nominal at 230/115v supply

For a complete kit with a saving over buying the options separately see PrimeTest 350PAT solution package RS stock no. 461-086

Supplied with: Operating manual, earth & insulation test probe, mains lead with UK 13A mains plug

or Aus/Nz depending on model.

Description Stock no. Price

per

OM S$ S$ S$

Seaward SuperNova 2000 342-8805 unit 1+ 3690·00

Supplied with: Carry case, mains lead,1.2m test lead and crocodile clip, IEC test lead, battery charger,

6 LR6 NiMH rechargeable batteries, instruction manual, utilities CD-ROM,RS232 to PC cable, RS232 to

USB adaptor, & 110V/230V socket adaptor, 30-day PATGuard evaluation disk. Earth Bond Test Test Voltage* 6V nominal (no load)

Test Current* 4A, 10A, 25A selectable (into s/c load)

Range 40mΩ - 19.99Ω

Resolution 0.01Ω

Accuracy ± 5% of reading,± 2 digits

Pass Levels Selectable

Misc 4-wire measurement, floating earth

DC Earth Bond Test Test Voltage* 4V nominal (no load)

Test Current* -200mA, +200mA selectable (into s/c load)

Range 40mΩ - 19.99Ω

Resolution 0.01Ω

Accuracy ± 5% of reading,± 2 digits

Pass Levels Selectable

Misc 4-wire measurement, floating earth

Earth Screen Test Test Voltage* 100mV nominal (no load)

Test Current* 100mA (into s/c load)

Range 40mΩ - 19.99Ω

Resolution 0.01Ω

Accuracy ± 5% of reading,± digits upto 5.00Ω

Pass Level Selectable

Misc 4-wire measurement, floating earth

Insulation Test Short Circuit Current 2mA dc maximum

Measuring Range 100kΩ - 100 MΩ

Resolution 0.01 MΩ

Test Voltage* 500V dc or 250V dc nominal (0.5MΩ load)

Accuracy ± 5% of reading, ± 2 digits (100kΩ - 20MΩ)

Pass Levels 0.5MΩ, 1.0MΩ, 2.0MΩ, 4.0MΩ, 7.0MΩ

Leakage Range 0.1mA - 10.0mA

Resolution 0.01mA

Accuracy ± 5% of reading, ± 2 digits

Pass Levels 0.25, 0.5, 0.75, 1.5, 2.25, 2.5, 3.0, 3.5 & 9.9mA

Load Test Voltage Measurement 90 - 300V Indication only

Current 0 - 4kVA Indication only

IEC Lead Test Test Voltage* 40V ac

Detects Open, Short, Good, Reverse

* Test stimulus based on mains supply of 230V, varies with supply voltage.

Test Current Phase: 0°/180° auto switched onalternate cycles

Measurement Resolution: 0.1Ω (Max)

Test Duration: 2000 ms maximum if RCDdoes not trip

Lead Test

Measuring Range: 10ms - 2000ms Test voltage: 9 VDC Operating Error: ±10 % Test Duration: 2s Measurement Resolution: 1ms Test: Live / Neutral Checks for

o/c, s/c and crossed Earth Loop Resistance Test Power Socket Test

Test Voltage: 230V +10 %, -15 % Input voltage range: 230V +10 %, -15 % AC Test Current: Such that it will not trip at

30mA RCD Indicators: phase to earth voltage

phase to neutral voltageneutral to earth

Measuring Range: 1Ω - 199Ω Dimensions 208 x 110 x 60 mm Operating Error: ±10 % +2 digits Weight 1.52 kg

Stock no. Price per OM S$ S$ S$

717-3647S unit 1+ 2722·00

Description Stock no. Price per OM S$ S$ S$

PrimeTest 300, Aus/NZ 163-851 unit 1+ 3900·00

2263

www.nguyenxuong.com

Page 29: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Seaward PAT Tester Accessories

Fluke Portable Appliance Testers

Megger Portable Appliance Testers

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple a New product to range

Test n Tag K3100 Bluetooth Adaptor

Seaward CCD Barcode Scanner

Test ’n’ Tag PAT Label printer

6200 Manual PAT Tester

PAT4DV & PAT4DVF Dual VoltageTesters

PAC3760 Plus Aus/NZ

Aust/NZ PAT - Seaward PAC3760

Compact and light weight portable appliance tester suitable for

testing both 230V and 110 V Class I and II appliances. Ideal for

manual testing and low volume applications.

These microprocessor controlled instruments are designed

for maximum flexibility coupled with ease of use. They carry

out routine safety tests on both 110V and 230V portable

appliances and extension leads. The LCD display shows full

details of clients and appliances which have been uploaded

from data storage and which can be downloaded

subsequently to a PC for certification and storage.

Dedicated key for each test for ’one-touch’ testing

Pre-set pass/fail levels to save time

Large backlit display for easy reading

Internal memory to store 100 tests

Separate IEC socket for easy mains/extension lead testing

Detachable test leads for quick field replacement

The Test ’n’ Tag PAT label system prints durable

synthetic tags immediately after the Portable

Appliance test. It replaces the need for

The PAC3760 is a next-generation PAT tester

designed specifically for standards AS/NZS

3760:2003

Connects to the Seaward Test ’N’ Tag model

K3100 printer to enable wireless Bluetooth

communication with the Seaward PrimeTest 300

Non-contact CCD barcode scanner for rapid

entry of appliance number, test codes and

asset ID details .

Circuit test checks appliance is not open circuit or short

circuit

Earth Continuity test in accordance with EEA

recommendations for IT Equipment

Simple Pass/Fail indication and automatically conducts a sequence of tests

Unique 3 button operation, class I, class II and leakage

Automatically detects if the unit under test is switched on

Auto-sense of IEC leads and extension cords

and Primetest 350 handheld PAT tester.

Earth bond low (low/high current)

Insulation 500 V

Leakage (PE current, touch current, substitute current)

Can test 110 V appliances (earth bond, insulation) via the 110 V adapter (Fluke TA700 rs 512-5766)

240V equipment load test

Supplied in a protective hard carrying case with extra storage space for accessories and other tools.

RS-232 port for printing test results

9 Way D type connector

Directly compatible with Seaward PATS :- Supernova

Plus, Supernova Plus Xe, Supernova, Europa Plus,

PAT,Europa Plus PAT, PAT2000i, PAT2000iee

Compatible with the Seaward PrimeTest 300 via Barcode

Scanner Bluetooth Adaptor (stock No. 513-7078)

Popular and easy-to-use appliance tester now

upgraded with more features.

handwriting any test labels and saves time by fully

automating the PAT testing process.

Designed to work with the Seaward Europa Plus, Supernova

Plus and Supernova Xe PAT testers.

Insulation test at 500V d.c., into 0.5MΩ load or greater with user settable pass bands

Earth Leakage test measures earth leakage via differential method to cover multiple earth paths

Fuse Test to check for blown fuses

Flash test (ON DVF ONLY)

Visual checks

Stores up to 1000 test results with full client and asset details including descriptions for download

to a PC

Full details can be uploaded from PC storage for on site history during retest

Alphanumeric keypad

Serial connection for PC and serial printer

Parallel printer connection

Compact thermal transfer printer

Portable and lightweight

Security and accuracy of information is assured as test

details are direct from the tester’s memory

Stock no. Price per OM S$ S$ S$

500-2865 unit 1+ 1350·00

Class I & II appliances, Class I leads and powerboards

Leakage test for Class I and Class II appliances

10mA & 30mA RCD trip-time test

3 phase insulation & leakage testing with optional adaptors

Battery or mains power operation

Full readings displayed with Pass/Fail indication

Bluetooth communication range up to 10m

Power on and Bluetooth LED indicators

Bluetooth connection LED indication

RJ11 communication interface to printer

DC power supply lead to derive power from the Test ’N’ Tag

printer

Unit is a Bluetooth server module

For a complete Fluke 6200 manual PAT tester solution with a saving over buying the options

separately, a 6200 kit is available comprising:

Stock no. Price per OM S$ S$ S$

514-4824 unit 1+ 680·00

6200 tester with standard accessories and hard case

EXT100, Extension lead test adaptor

560 appliance pass labels

100 appliance fail labels

Register for PAT (Log Book)

Description Stock no. Price per OM S$ S$ S$

PAT4DV AU 163-980 unit 1+ 3080·00

PAT4DVF AU 163-996 unit 1+ 3670·00

Supplied with: Carry Case, Earth Bond Lead, Mains Supply Test Lead, IEC Lead &

Training DVD.

Own company name can be customised onto the labels.

Label design includes a barcode, asset number, test date and next test date

Label size approx. 6cm long and 2cm wide

Industrial tape cartridges 25.4mm wide by 12m long are available separately

Dimensions (LxWxH): 152 x 95 x 100

For Compatible black on yellow tape cartridge, RS Stock No. 475-1409, black on white RS Stock No.

539-0998

Stock no. Price per OM S$ S$ S$

399-634 unit 1+ 375·00

Associated accessories

Display Backlit LCD grahics

Indication Pass/Fail, Measurement Value

Enclosure rating IP40

Overvoltage Category CAT II 300V

Electrical Safety IEC61010-1:2001, IEC61326:2005

Dimensions 265 x 110 x 55mm

Weight 800g

Supplied with: Seaward serial port lead and 14Vdc 1.6A mains adaptor

Type PAT Tester Download No Supply Voltage 230 V ac Flash Test No Test Type Class I and II

SP1000, EXT100 & TA700 (see the ’6500 Auto-Test PAT Tester’ for details)

Note: Options of printer with UK or Aus/Nz mains lead

Type Stock no. Price per OM S$ S$ S$

PAT Tester 712-6020a unit 1+ 1128·00

Supplied with: Hard carry case with test lead, test probe, crocodile clip, UK 230V mains lead and

instruction manual.

Description Stock no. Price per OM S$ S$ S$

Test ’N’ Tag Printer BS1363 456-1256 unit 1+ 790·00

Test ’N’ Tag kit, black onyellow cartridge

475-1409 unit 1+ 91·00 3+ 87·50

Test N Tag cartridge blackon white

539-0998 unit 1+ 86·00 3+ 82·50

Description Stock no. Price per OM S$ S$ S$

Supernova Xe (Aus/NZ) 537-2625 unit 1+ 4090·00

Contact RS for calibration requirements

Stock no. Price per OM S$ S$ S$

712-5976S unit 1+ 2147·00

2264

www.nguyenxuong.com

Page 30: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Port.Appliance Checkers

Kyoritsu Portable Appliance Tester

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

New products available online every week

Seaward PrimeTest 100 (UK)

Kyoritsu Kew 6201A

Contractor PAT & ElectricalCertification Software

PAT400 Series DownloadingPortable Appliance Testers

PAT300 Series Portable ApplianceTesters

Powersuite Professional Contractor offers all the features of PowerSuite

Lite with the addition of a data based client, assets and results

management database for managing 17th Edition electrical and Portable

Appliance test results. All records and downloaded data is allocated to the

appropriate customer on which a number of reports can be run

Performs 4 test functions to ensure safety of Class I

and Class II appliances

Readings displayed on large, clear LCD with pass or

Portable desktop appliance testers providing manual or

automatic electrical equipment safety testing in accordance

with DIN VDE 0701-0702.

Easy to use handheld tester with the

functionality of a PAT checker, an IEC lead and

fail indication

Available in Australia/New Zealand and Singapore versions

Large 5.7in. ¼ VGA backlit colour

screen for clear & easily

understandable results

5 user defined soft-keys for direct

access to frequently used functions

Full QWERTY keypad for easy and

precise data entry.

10,000 record memory for

interruption-free testing.

USB port for quick download to a

memory stick eliminating the need

to take the tester back to the office

every night, data is directly

compatible with Megger PowerSuite

Work in real certificates and forms

Client and results database manages links between customers and their

test results

Download test results from Megger downloading PAT testers, Megger

downloading electrical installation testers and third party test equipment

or direct data entry to certificates

Real time results transfer via Bluetooth with Megger MFT1553 electrical

installation tester

Import company logo and add header page to customise certificates for

250V and 500V insulation tests & 200mA continuity test

Differential, substitute & touch current tests with 10 μA

resolution

High resolution backlit colour screen with all test details

displayed before, during and after testing

Tests standard, RCD protected and anti-surge extension

leads

Instant re-start for faster testing across multiple rooms

Pre-defined test sequences

Adjustable test pass limits and adjustable test duration

times

Standards: IEC 61010-1 CAT III 300V pollution degree2, IEC61326-1, AS/NZS 3760

software.

2 USB ports for optional barcode reader & printer

Selectable PASS/FAIL limits provide instant indication of a faulty asset

200 mA continuity test

250 V and 500 V insulation tests prevents damage to sensitive electronics

Instant re-start for fast testing across multiple rooms

Tests for standard, RCD-protected and anti-surge extension leads

Interrupt-time tests for portable or plug-in RCDs

Adjustable test times allow faster testing for increased productivity

Differential, Substitute or Touch leakage current tests

Operational test with VA display

a professional appearance

Print on plain paper or pre-printed forms

Extensive range of certificate formats and supports IEE, NICEIC, ECA, SELECT and ELECSA and BS

electrical test certificates

Full range of PAT testing certificates including repairs cerificates

Reports module generates a wide range of reports for electrical installation testing and PAT testing.

Project billing certificates and reports

Digital imaging module allows picture import for increased clarity in reports

Organiser module for scheduling workload, site work and retesting etc. with graphical diary

Extended forms offer alternative and extra certificate formats including filling stations and security

systems, ensuring there is a certificate to meet your requirements

Push-button operation for test groups or individual test functions

Test results are marked as a PASS or FAIL, and compared to the pass/fail limits for each test

indicating a good or marginal result

Selectable PASS/FAIL limits

Direct testing of IEC power cords with no adapter

Supplied with: Power cord, 7129 test leads, 7101 flat test bar, 7140

adapter, probe case, shoulder strap & manual

PAT320 only:

PAT410 Features:

Note: System Requirements: Pentium IV PC running XP or Vista operating system; 128MB RAM

(Min); 100MB hard disk space; CD-ROM drive; COM1 RS232 port (or USB port with USB to RS232

adaptor) for use with downloading PAT testers; Bluetooth for use with Megger MFT1553

Light weight, low current Portable Appliance Tester, configurable for fast testing and high

productivity.

230V operation & testing

Conductor Resistance Test Measuring current 2.5mA dc or less Measuring Range 0 - 15.00 Ω Accuracy ± (2% rdg +3 dgt) Resolution of measurement 10 MΩ Leakage Current Test

Open circuit voltage <12 Vac Measuring Range AC 0.1 - 19.99 mA Measuring current 10 Aac nominal value Resolution of measurement 0.01 mA Accuracy ± (3% rdg +5 dgt) Examination time Max 15s Insulation Resistance Test Accuracy ± (3% rdg +5 dgt) Rating 250 V / 20 MΩ Mains Voltage Check

Measuring Range 0 - 19.99 MΩ Measuring Range 207 - 264 Vac Resolution of measurement 10KΩ Resolution of measurement 1 V Output voltage 25 0Vdc (+20% / -10%) @ 1MΩ Accuracy ± (2% rdg +3 dgt)

Stock no. Price per OM S$ S$ S$

667-8359 unit 1+ 1090·00

10A & 25A High current test capability

Supplied with: User Guide CD, extension lead adaptor, quick-start guide, carry case and document

wallet, bond/continuity test lead with croc-clip and probe.

Description Stock no. Price per OM S$ S$ S$

Kew 6201A Aus/NZ 410-703 unit 1+ 1100·00

Kew 6201A SG ver 543-273 unit 1+ 880·00

PAT420 Features:

Bond Test (PAT320 only) Touch Current Test

Test voltage 9Vac nominal Test Voltage Mains 115/230Vac,50/60Hz

10A Test 10A rms ±20% nominal Display Range 0 → 5mA

26A Test 26A rms ± 5% nominal Accuracy ±5% ± 30μA

Display Range 0 → 1.99Ω Resolution 10μA

Accuracy ±5% nominal Operational Test

Resolution 1mΩ , 10mΩ Test Voltage Mains 115/230Vac

Continuity Test Display Range 0 → 4KVA.

Test Voltage +4.5Vdc ± 10% Accuracy ±5% nominal

Test Current ±200mA ± 10% Resolution 1VA � 10VA

Display Range 0 → 19.99Ω Displays Load VA, voltage and current

Accuracy ±5% nominal Extension Lead Test

Resolution 1mΩ, 10mΩ Tests Insulation and Bond tests

Insulation Test Polarity Test Lead OK; LN S/C;

Test Voltage 250Vdc, 500Vdc nominal LN Reversed; L/N O/C

Display Range 0 → 100MΩ Portable RCD test

Accuracy ±2% , ±5% nominal Test Current Accuracy -8% to –2% (½ x I)

Resolution 10KΩ, 50KΩ +2% to +8% (1 x I, 5 x I)

Substitute Leakage Test Trip Time Display Range 0 → 1999ms (½ x I)

Test Voltage 40Vac ±5%, 50/60Hz 0 → 300ms (1 x I)

Display Range 0 → 19.99mA 0 → 40ms (5 x I)

Accuracy ±5% ± 100μA Accuracy ±1% ± 5 digits

Resolution 10μA Resolution 100μs

Differential Leakage Current Fuse Test

Test Voltage 115/230Vac, 50/60Hz Display OK, Open Circuit

Display Range 0 → 19.99mA

Accuracy ±5% ± 100μA

Resolution 10μA

Dual 230V and 110V operation and testing for industrial, commercial and residential applications

10A and 25A bond test with high duty cycle and no overheating on repetitive tests

Description Stock no. Price per OM S$ S$ S$

PAT320 BS1363 712-5755S unit 1+ 1952·00

PAT450 Features:Dual 230V and 110V operation and testing for industrial, commercial and residential applications

10A and 25A bond test with high duty cycle and no overheating on repetitive tests

Flash test at 1.5kV and 3kV, ideal for industrial, tool hire and service workshops

Accessories

Supplied with: User Guide CD, extension lead adaptor, quick-start guide, carry case and document

wallet, IEC C6 to C13 plug adaptor, bond/continuity test lead with croc-clip and probe, High Voltage

probe(PAT450 only)

Description Stock no. Price

per

OM S$ S$ S$

415V 5-pin to BS1363 AdaptorLead

666-6081 unit 1+ 98·00

415V 4-pin to BS1363 AdaptorLead

666-6088 unit 1+ 98·00

Description Stock no. Price per OM S$ S$ S$

PAT 410 Aus/NZ 721-2461a unit 1+ 2908·00

PAT 420 Aus/NZ 721-2465a unit 1+ 3283·00

2265

www.nguyenxuong.com

Page 31: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Flash/Hi-Pot Insulation Testers

Appliance Servicing Tester

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple a New product to range

Fluke 1550, 1555 5kV and 10kV InsulationTester

MIT510/2 & MIT520/2 5kVInsulation Testers

My Account

www.rssingapore.com

MT204-S Machine TesterTests to the requirements of European standard IEC/EN 60204 and

the German standard DIN VDE 0113 part 1.

Earth bond resistance measurement, test current 10 A or 0,2 A

Loop-/ Line impedance measurement up to 440 V with display of

prospective short circuit current PSC

Insulation resistance measurement with 250 V or 500 V

Residual voltage test, display of discharge voltage or discharge time

Integrated high voltage test with 1000Vac can be deactivated via key

switch

Measurement memory for approx. 2000 values

Integrated interface (USB 2.0) for transferring measurements to PC

Separate interface (USB 2.0) for connecting a barcode scanner, USB

keyboard or USB key

Graphical LCD for measured values, limit values and parameters

Easy to use by rotary switch and START/STOP button

5kV insulation resistance testers in a rugged IP65 case to

enable simple safety checks on insulation and also a range

of predictive tests for preventative maintenance.

Safety features include automatic discharge of capacitive

energy, test inhibit if >50V detected at test leads and timed

start button to prevent inadvertent operation if button is

jammed etc.

High voltage insulation tester ideal

for testing high voltage equipment

including switchgear, motors,

generators and cables.

Meets requirements of IEEE 43-2000

Capacitance and leakage current

measurement

Resistance measurements up to 2TΩ

(Fluke 1555)

Ramp function for breakdown

testing

Voltage breakdown detection alerts

and voltage reading up to 600 V ac or

dc for increased user safety

extension lead tester and a power socket polarity checker.

One pair of sockets for all measurement tasks

EN61010 safety rating CAT IV 300V, CAT III 600V

Easy data entry barcode scanner (RS 700-7803) and USB keyboard (RS 704-7390) are available as

optional accessories.

5kV dc test voltage, 3mA short circuit current

Automatic IR test

15TΩ resistance range

Guard terminal for enhanced accuracy (guard test lead

supplied)

99 measurements storage and recall and PC interface

Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI)

Timer settings up to 99 minutes for timed tests

Guard system eliminates the effect of surface leakage current on high-resistance measurements

Large LCD display with analogue bargraph

Long life lead acid battery with over 750 tests between charges

EN 61010 safety rating CAT IV 1000 V, CAT III 1000 V

Battery powered with mains supply for power or battery recharge

Operating temperature range -20°C to +50°C

Digital/Analogue backlit display

Voltage, leakage current, capacitance, time constant display

99 minute count up timer

Complies with EN61010-1 Cat IV 600V

Quick reference guide inside the lid

Supplied with: Compact carry case, mains lead, 2 x 2m safety test leads, 2 x 10m extension test leads,

2 crocodile clips,1 interface cable and user manual

Two electrical safety checks in one tester

6 automated test sequences

Checks appliance safety and socket safety

Simple pushbutton test sequence giving for Class I, Class II, Leakage

and Lead tests

LCD display giving clear PASS/FAIL indication

Tests Class I and II equipment including IT and business equipment

Differential Leakage test

Extension and IEC lead tests

Power socket polarity

Detects load of appliance under test to check for power switches

which are off and/or appliances which may draw excessive current

Supplied with: Test cables & crocodile clips, infrared USB adaptor, AC power cord, 12V lead acid

battery (fitted), FlukeView Forms Basic Software, user manual on CD-ROM, soft carrying case (Fluke

1555 only)

Fluke 1550 & 1555 kits include: IP67 hard case, NIST traceable certificate of calibration and

additional ruggedized crocodile clips

Display Graphical LCD, 128 x 64pixels

Insulation resistance 0.00 → 100.0 MΩ, 0.01MΩ, 0.1 MΩ

Protective earth resistance(10A)

0.00 → 20.00 Ω/0.01 Ω Test voltage /current 250 → 500 V (in 10V steps)>1 mA DC

Max. test current/voltage > 10 A / > 4 V AC Residual voltage measurementrange

0.0 → 400 V AC/DC

Protective earth resistance(0.2A)

0.00 → 4.00 Ω/0.01 Ω High voltage test voltage/current

1000V / 50mA AC

Test Current/Voltage > 0.2 A / > 4 V AC Trip current 5, 10, 25, 50mA (adjustable) Loop/Line Impedance 0.00 → 20.00 Ω/0.01 Ω Power Supply 230V +10%/-15% 50 Hz, max.

100 VA Test current 20 A (10ms) @ 230V Dimensions & weight 340 x 310 x 170 mm: 7kg

Supplied with: Test leads, carry case and comprehensive user

MIT520/2 additional features

instructions.

Stock no. Price per OM S$ S$ S$

700-7806S unit 1+ 3610·00

Pre-programmed tests: PI, DAR, SV(Step voltage),

Dielectric Discharge (DD) test for multilayer insulation, ideal for detecting cavities in generator &

motor armature windings

Selectable audible alarm points indicates when required insulation level is attained – saving test

time in production & repetitive testing applications.

Selectable breakdown or burn mode

Real time data output-RS232 and USB

32kB data storage

Download software using Megger Download Manager (supplied)

Variable test voltage and time intervals

Note: Please contact RS for calibration requirements

Earth Continuity Load Current 13A maximum Test Current ±200mA DC Test Duration 30s maximum user controlled Test Duration 60ms nominal Pass Value 3.5mA ± 0.2mA Class I

0.25mA ± 0.05mA Class II Pass Value 0.2Ω IEC Lead Test

Insulation Resistance Test Voltage 7V nominal Test Voltage 500Vdc Test Duration 2s nominal Test Current 1mA into 500kΩ 2mA short circuit Test Earth Continuity

Insulation ResistanceLive, Neutral Continuity and Polarity

Test Duration 2s nominal Power Socket Test

Pass Value 2 MΩ Input Voltage Range 230V ±10% - 15% AC Differential Leakage Voltage Indication Phase to Earth Voltage

Phase to Neutral VoltageNeutral Earth

Test Voltage 230V ± 10%

Accessories

Supplied with: 3m test lead set, USB & RS232 download leads (MIT520/2 only) and Download

Manager software (MIT520/2 only) user guide.

Test Voltages dc 250V, 500V, 1kV, 2.5kV, 5kV and 10kV (Fluke 1555 only)-0%, +10% at 1mA load current

Resistance measurement 200kΩ → 100 GΩ: ± 5%,(Fluke 1550)200kΩ → 200 GΩ: ± 5%,(Fluke 1555) 200GΩ → 1TΩ: ± 20% (Fluke 1550)200GΩ → 2TΩ: ± 20% (Fluke 1555)

Bargraph range 0 → 1 TΩ

Leakage current measurement 1 nA to 2 mA ±(5% + 2 nA)

Capacitance Measurement 0.01 μF to 15.00 μF ±(15% rdg + 0.03μF

Voltage input range 95-240 V ±10% rms 50/60 Hz and DC Capacitancemeasurement

10nF to 50μF (dependant onmeasurement voltage); ±5% ±5nF

Battery life 8 hours continuous testing at 5kV Voltage outputaccuracy (0°C to 30°C)

±4% ±10V of nominal test voltage at1GΩ load;±25V for test voltages less than 500V

Test voltages 50 to 1Kv in 10V steps1Kv to 5kV in 25V steps

Current measurementrange

±0.01nA to ±5mA ; ±5% ±0.2nA

Accuracy (23°C) ±5% to 1TΩ; ±20% to 10TΩ Display Analogue/Digital 3 digits Guard 2% error guarding 500kΩ leakage

with 100MΩ load Interference rejection 2mA rms @ 200VB and above

Display range Digital display 10kΩ to 15TΩ;Analogue display 100kΩ to 1TΩ

Timer range Counts up to 99 minutes from startof test

Short circuit/chargecurrent

3mA Dimensions 305 x 194 x 360 mm

Capacitor charge time ≤5 seconds per μF at 3mA Weight 7.1 kg Capacitor dischargetime

<120ms seconds per μF todischarge from 5000V to 50V

Stock no. Price per OM S$ S$ S$

717-3653S unit 1+ 947·00

Description Stock no. Price per OM S$ S$ S$

Barcode Scanner, USB 700-7803 unit 1+ 580·00

Keyboard, USB, UK 704-7390 unit 1+ 90·00

Description Stock no. Price per OM S$ S$ S$

MIT510 712-5761S unit 1+ 5012·00

MIT520 712-5765S unit 1+ 6394·00

2266

www.nguyenxuong.com

Page 32: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Cable Tracers/Fuse FindersCable Fault Locators

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Many more leading brands from over 2,500 suppliers available online

Fluke 2042 Kit

Lexxi T810, Cable Fault Locator

Lexxi T810

MIT1020 10kV Insulation Tester10kV insulation resistance tester in a rugged IP65 case to

enable simple safety checks on insulation and also a range

of predictive tests for preventative maintenance. IEEE 43-

2000 recommends the use of 10kV for motor windings rated

above 12kV.,Safety features include automatic discharge of

capacitive energy, test inhibit if >50V detected at test leads

and timed start button to prevent inadvertent operation if

button is jammed etc.

Cable locating set comprising a transmitter and receiver in a hard

carrying case. The transmitter connects to the cable / metal pipe to

be traced and sends a carrier signal containing a user-selected

code. The non-contact receiver detects the signal and displays the

code. Additional transmitters are available to allow multiple cables

/ pipes to be traced and identified. Both live and dead circuits can

be located.

H.260, W.110D.75, Wt.750g

Automatic cable attenuation compensation simplifies use

Narrow pulses give high resolution trace image

Automatic default pvf, impedance and gain algorithm set by cable selection

Traces cable & metal water/heating pipes in walls and

underground

Locates fuses and assignment to circuits

Locates concealed sockets and distribution boxes

Locates interruptions and short-circuits in unshielded electrical

cables & underfloor heating

Tracing depth up to 2.5m dependant on material (concrete etc.)

Mains voltage location up to 0.4m

Large, high resolution display

Tactile push buttons

Wide operating temperature range for field use

10kV dc test voltage, 3mA short circuit current

Automatic IR test

35TΩ resistance range

Guard terminal for enhanced accuracy (guard test lead

supplied)

Ranges from 10m to 3000m

Automatic cable attenuation compensation simplifies use

Narrow pulses give high resolution trace image

Select one or more test leads to suit your application:

Transmitter LCD display for transmission level, transmitting code and external voltage

Receiver with LCD display of received signal level, code and live voltage indication

Torch lamp function

Battery powered with mains supply for power or battery recharge

Rugged polypropylene case

IP65 ingress protection (lid closed)

Operating temperature -20°C → +50°C

Digital/Analogue backlit display

Voltage, leakage current, capacitance, time constant display

Pre-programmed tests: PI, DAR, SV(Step voltage),

Dielectric Discharge (DD) test for multilayer insulation, ideal for detecting cavities in generator &

motor armature windings

Selectable audible alarm points indicates when required insulation level is attained – saving test

time in production & repetitive testing applications.

Selectable breakdown or burn mode

99 minute count up timer

Complies with EN61010-1 Cat IV 600V

Quick reference guide inside the lid

Real time data output-RS232 and USB

32kB data storage

Download software using Megger Download Manager (supplied)

Variable test voltage and time intervals

Automatic default pvf, impedance and gain algorithm set by cable selection

Large, high resolution display

Tactile push buttons

Wide operating temperature range for field

MIT1020 10kV Insulation Testers

L810/3/PWR - LV power cable see RS stock no. 315-8332

L810/3/75 - Coax CATV, 75Ω see RS stock no. 339-8287

L810/3/100 - telecoms and data comms 100Ω twisted pair cable, see RS stock no.

339-8300

L810/3/BNC - F-BNC & BNC to F outlet adaptor see RS stock no. 339-8322

Supplied with: carry bag, operating manual and batteries.

Supplied with: Carry Bag, operating manual and batteries.

Supplied with: 3m test lead set, USB & RS232 download leads and Download Manager software user

guide

Select the instrument T810, then select one or more test leads to suit your application.

Charging Rate for capacitive load 5 seconds per μF

Discharge rate for capacitive load 1.55 seconds per μF

Live circuit warning 30 V → 660V ac/dc 50/60Hz ±(15% + 2 V)

Power 12V Lead-acid rechargeable battery: internal mains powered charger

Dimensions & Weight 269 x 277 x 160mm : 3.7kg

Voltage input range 95-240 V ±10% rms 50/60 Hz and DC Capacitancemeasurement

10nF to 50μF (dependant onmeasurement voltage); ±5% ±5nF

Battery life 4 hours continuous testing at 10kV Voltage outputaccuracy (0°C →30°C)

+4% ±10V of nominal test voltage at1GΩ load;±25V for test voltages less than500V

Test voltages 50 → 1kV in 25V steps, 1kV → 10kVin 25V steps

Current measurementrange

±0.01nA → ±5mA ; ±5% ±0.2nA

Accuracy (23°C) ±5% → 1TΩ; ±20% → 20TΩ Display Analogue/Digital 3 digits Guard 2% error guarding 500kΩ leakage

with 100MΩ load Interference rejection 2mA rms @200V and above

Display range Digital display 10kΩ to 35TΩ;Analogue display 100kΩ to 1TΩ

Timer range Counts up to 99 minutes from startof test

Short circuit/chargecurrent

3mA Dimensions 305 x 194 x 360 mm

Capacitor charge time ≤5 seconds per μF at 3mA Weight 7.1 kg Capacitor dischargetime

≤250ms per μF to discharge from10000V → 50V

Pulse characteristics

Width 7nS to 2μS selected according to range, nominally 8% of range Amplitude 5V nominal when unterminated Output impedance 25Ω, 50Ω, 75Ω, 100Ω, switchable Output 2 x 4mm on 19mm pitch Protection Instrument will not be damaged by direct applications of 250V a.c. rms 50/60Hz to the input.

For safety reasons, however, it should NOT be operated under these conditions. For safe useon cable carrying hazardous live voltages, the blocking filter test lead must be used.

Display LCD 128 x 64 pixels with back light Cursor Single vertical line Modes

Real time Single trace cable type select (sets pvf default gain algorithm & impedance) screen contrast,with automatic temperature compensation Units - meters or feet pvf adjustment

Power 6AA size LR6 batteries Operating temperature -20 to +55°C Dimensions 250 x 100 x 95 mm Weight 0.6 kg

Ranges (nominal) 10m, 30m, 100m, 300m, 3000m at a pvf of 0.67 Accuracy Better than 0.9% of range Resolution 1% of range Propagation velocity Variable 0.2 to 0.99 pvf Gain Automatic (varied across screen)

L810/3/PWR - LV power cable

L810/3/50- Coax LAN cable, cellular, TV & satellite antennae, 50Ω

L810/3/75 - Coax CATV, 75Ω

L810/3/100-telecoms and data comms twisted pair cable,100Ω

L810/3/BNC- F-BNC & BNC to F outlet adaptor

Ranges (nominal) 10m, 30m, 100m, 300m, 3000m at a pvf of 0.67 Accuracy Better than 0.9% of range Resolution 1% of range Propagation velocity Variable 0.2 to 0.99 pvf Gain Automatic (varied across screen) Pulse characteristics Width 7nS to 2μS selected according to range, nominally 8% of range Amplitude 5V nominal when unterminated Output impendance 25Ω, 50Ω, 75Ω, 100Ω, switchable Output 2 x 4mm on 19mm pitch Protection Instrument will not be damaged by direct applications of 250VAC rms 50/60Hz to the

input. For safety reasons, however, it should NOT be operated under these conditions.For safe use on cable carrying hazardous live voltages, the blocking filter test leadmust be used.

Display LCD 128 x 64 pixels with back light Cursor Single vertical line Modes Real time Single trace cable type select (sets pvf default gain algorithm & impedance) screen

contrast, with automatic temperature compensation Units - metres or feet pvfadjustment

Power 6AA size LR6 batteries Operating temperature -20°C to +55°C

Type Insulation Resistance Tester Safety EN 61010 safety rating CAT IV 1000 V, CAT III 1000 V Display Type LCD with analogue bargraph

Stock no. Price per OM S$ S$ S$

712-5774 unit 1+ 8095·00

Stock no. Price per OM S$ S$ S$

669-9552 unit 1+ 2250·00

Manu. Part No. Stock no. Price per OM S$ S$ S$

10/L810/3/50 339-8293 unit 1+ 73·50

Description Stock no. Price per OM S$ S$ S$

Fluke 1550 5kV Tester 705-1957S unit 1+ 5124·00

Fluke 1550 5 kV Tester Kit 705-1951S unit 1+ 5773·00

Fluke 1555 10kV Tester 705-1960Sa unit 1+ 6353·00

Fluke 1555 10 kV Tester Kit 705-1963S unit 1+ 7074·00

Accessories

Description Stock no. Price

per

OM S$ S$ S$

L810/3/PWR test lead for powercable

339-8287 unit 1+ 370·00

L810/3/75 test lead for 75Ωcoax

315-8332 unit 1+ 86·50

L810/3/100 test lead for 100Ω t/pair

339-8300 unit 1+ 86·50

L810/3/BNC-F BNC to F Adaptor 339-8322 unit 1+ 73·50

2267

www.nguyenxuong.com

Page 33: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple a New product to range

Meterman ECB50

Amprobe ECB50A

Elite Professional Fuse Finder KitMartindale FD650

Ideal 61-954 & 61-958 SureTest CableTracer Kits

61-958

The transmitter module generates a coded signal that is injected

into a powered AC line, and the receiver wand uses this signal to

The multi-purpose version of the popular FD550. Supplied in

a robust case complete with transmitter and receiver,

additional features include a 13A plug top lead for sockets

and fused test lead set with crocodile clips for junction boxes,

terminals and lighting circuits.

The ECB50 is offered in 100 to 250V configuration. The transmitter

reject noise and correctly identify the correct circuit breaker or fuse wire.

module generates a coded signal that is injected into a powered AC line. The receiver wand

uses this encoded signal to reject noise and correctly identify the right circuit breaker wire.

Supplied with: 13A plug in transmitter, Elite receiver &

instructions, rugged hard carry case, TL93 leads with

crocodile clips, 13A mains adaptor.

Includes 2042 receiver, 2042T transmitter, 4 test leads, 2 crocodile clips and 2 test probes

Three testers in one:-

Three testers in one:

61-954

Stock no. Price per OM S$ S$ S$

719-0908S unit 1+ 253·00

Note: Additional transmitters are available separately for extension or to distinguish between several

signals

Identify circuit breaker to electrical sockets

Trace AC cables in walls

Identify AC wires in a bundle

2 troubleshooting test tool kits for

finding circuit breakers and

hidden wire problems in electrical

wiring installations. These tracers

work on energized and de-

energized circuits. They identify

circuit breakers, find open and

shorts circuits and trace wires

behind walls and underground.

Identify circuit breaker to electrical socket:

Trace AC cables in walls

Sort AC wires in a bundle

Supplied with: Hard carry case, instructions, PP3 battery and 6xAA alkaline batteries

Identifies breakers & fuses

Pinpoints open & short circuits

in unshielded electrical cables

Traces wires behind walls

Locates cables, conduit or

metal pipe underground to a

depth of 4.5m

Additional features:

Additional features:-

Technical data

Transmitter: Dimensions 190 x 85 x 50 mm Display LCD with bargraph for external

voltage detection Weight approx. 450g

Voltage Receiver:

Measurement Range 12 to 400V (12V, 50V, 120V, 230V, 400V)Display 3½ digit LCD with bargraph for signalintensity

Frequency Range 0 to 60Hz Tracing Depth

Output signal 125kHz Cable Location Up to 2.5m wall/underground cables Max. Voltage up to 400Vac/dc Main voltage

detection Up to 0.4m

Measurementcategory

CAT III / 300V Power Supply 9V Battery (IEC 6LR61)

Pollution Degree 2 Dimensions 250 x 65 x 45mm Power Supply 6 x 1.5V Batteries (IEC LR6) Weight approx. 360g

TR-958 Transmitter

Microprocessor controlled

Coded transmission

Audible and visual indicators

Includes sensitivity adjustment

Cable tracing length to 150 meters (500 ft) nominal

Cable tracing depth to 40 cm (15 inches) nominall

Microprocessor controller

Coded transmission allows easy differentiation of transmitter signal

Audible and visual indicators

Includes sensitivity adjustment

Cable tracing depth to 400mm (15 inches) norminal

Receiver Tracing depth for fuse identification to 100mm (4 in) norminal

Standards: CAT lll 300V, Pollution Degree 2, Protection Class: IP20

Can be used on de-energized /energized circuits from 0-600V AC/DC

Live cable tracing without tripping RCDs

Indicates presence of AC/DC voltage

Meets EN61010 CAT III 1000V safety rating

Supplied with 3 AA alkaline batteries

Standards: EMC: EN 50081-1 and EN 50082-1, EN61010-1:2001

Description Stock no. Price per OM S$ S$ S$

2042 Cable Locator Kit 513-1799 unit 1+ 1357·00

2042T Additional Transmitter 513-1812 unit 1+ 662·00

Supplied with: Carry case & 9V battery

RC-954 receiver

Specifications Voltage range: 100 V to 250 V for ECB50-E

Power consumption: Approx 1 W

Transmitter Frequency range: 50 to 60 Hz for ECB50-E

Transmission frequency: Approx 8 kHz

Receiver Transmitter frequency: Approx 10 Hz

Tracing depth Approx 0 to 10 cm

for fuse identification: (4 in) depending on local conditions.

Tracing depth for Approx 0 to 40 cm

cable location: (15 in) depending on local conditions

Transmitter General Specifications

Operating temperature range: -10 °C to 40 °C max 80 % R.H.

Dimensions: 70 x 55 x 86 mm

Weight: Approx 65 g

Receiver General Specifications

Sensitivity setting Using On/Off control

Low battery indication 7.5 V

Switching fuse/cable Manually using Fuse-Line switch

Operating -10 °C to 40 °C

temperature range max 80 % R.H.

Dimensions: 22 x 162 x 34 mm

Weight: Approx 100 g

Power supply 9 V battery, IEC 6LR61, Alkaline only

Applicable directives EMC: EN 50081-1 and EN 50082-1 and standards

Transmitter: Low battery indication 7.5V Operating temperature range-10 to 40°C at max. 80% RH Switching fuse/cable manually using Fuse-Line

switch Overvoltage category CAT III 150 V Operating temperature range-10 to 40°C at max 80% RH Pollution degree 2, Protection Class: IP20 Overvoltage category CAT III 300 V Size and weight 70 x 55 x 86 mm, 65g Pollution degree 2, Protection Class: IP20 Receiver: Power Supply 9 V battery, IEC 6LR61, Alkaline

only Sensitivity setting Using On/Off control Size and weight 22 x 162 x 34 mm, 100g

Red LED display

Selectable receiver sensitivity modes: Search High, Search low, Trace mode & breaker mode

0-99 Numeric value display of signal strength & audible indication (pitch/tone) for easy to

understand tracing

Peak detecting bar graph display for detecting instantaneous changes in signal strength

Displays % of battery life remaining

Supplied with 4 AA alkaline batteries & connection lead set

Stock no. Price per OM S$ S$ S$

627-5755 unit 1+ 124·00

Stock no. Price per OM S$ S$ S$

543-879 unit 1+ 127·00

RC-958 ReceiverSuperbright OLED display

Rotating display for easy readout in all receiver orientations

Selectable receiver sensitivity modes: Search High, Search low, Trace mode & breaker mode

0-99 Numeric value display of signal strength & audible indication (pitch/tone) for easy to

understand tracing

Peak detecting bar graph display for detecting instantaneous changes in signal strength

Displays % of battery life remaining

Supplied with 4 AA alkaline batteries & connection lead set

Inductive Clamp with battery holder (IC-958)Connects to the TR-958 transmitter via 1.8m lead to induce a signal onto the circuit

25mm cable diameter clamp

Battery Pack holder with magnetic hanging strap (requires 6 type C cells not supplied)

61-958 currently not available

Contents

61-954 61-958

Transmitter TR-958 TR-958 Receiver RC-954 RC-958 Inductive clamp N/A IC-958 Carry case Yes Yes Test Lead Set Yes Yes

Transmitter Safety Complies with EN61010 Cat III, 1000V Operating frequency32kHzfixed amplitude, time modulated Receiver

Signal outputcurrent

200mA p-pmax into 50Ω Sensing Magnetic

Signal outputvoltage

30V nominal (2 Watts) Maximum Range 4.5m underground

Operating voltage 0- 600V ac/dc Signal response Numeric display and audible beep Battery Life 40 hours open circuit testing/25 hours

short circuit testing Battery life 20 hours

Indicators On/Off, Line Energized, Low Battery

Description Stock no. Price per OM S$ S$ S$

61-954 Cable Tracer Kit 613-1548 unit 1+ 1000·00

61-958 Cable Tracer Kit 613-1554 unit 1+ 1540·00

2268

www.nguyenxuong.com

Page 34: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

BS1363A Mains Socket Testers

Cable, Metal And Stud Detectors

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Visit our website for additional price information and exciting promotions

Cable and Metal DetectorMartindale TEK600

StudSensor i65 One Step

Wallscanner D-tect 150

Intellisensor� Stud Sensor

E-Ze Check Xtra MartindaleEZ150

Classic Check Plug MartindaleCP501

MT 6 Electronic Metal Locator

MultiScanner i700 One Step

MultiScanner i500 Zircon

Zircon

Zircon

Zircon

Scan through most non-metallic construction material including solid concrete,

tiles and marble (Not Wood or PVC pipes). A large LCD display pinpoints the

location of metallic targets to the nearest 2.54cm (1in.), and depth of the nearest

1.27cm (1/2in.).

A fast and easy way to test 13A sockets to BS 1363. When plugged

StudSensorTM i65 OneStep� quickly and easily locates studs behind non

metallic walls, floors and ceilings.

Patented CenterVision� technology finds the centre of studs in a single pass.

LCD display screen indicates direction, edge, and centre of studs

Signal strength indicator distinguishes between shallow and deep targets.

Find the centre of wood or metal studs or joists up to 38 mm (1-1/2 in.) deep

WireWarning� Alert provides continuous detection of unshielded energised

electrical conductors between 90 to 250V AC to a typical depth of 50mm (2

inches) for safety

ACT� (Auto Correcting Technology) corrects common user errors

automatically, such as when scanning begins over a stud.

Patented SpotLite� Pointing System shines a bright beam of light over target

centre

Rapid detection SCAN and precision LOCATE modes

Patented CenterVision� technology locates the centre and edges of wood or

metal studs behind non metallic walls, floors, or ceilings in one pass

Ideal detection tool to help to install cabinets, add electrical outlets, mount flat-

panel televisions on the wall, and other remodelling projects.

ACT�(Auto Correcting Technology) corrects common user errors

automatically, such as when scanning begins over a stud.

Backlit LCD screen with easy-to-understand on-screen graphics and audio

signal indicate target

The unique floating head design keeps the scanning head flat on rough surfaces

even if the handle is rocked or tilted.

Dual-sensitivity scanning—Normal mode up to 19mm (3⁄4 in.) or DeepScan� up

to 38mm (1 1⁄2 in.)

Finds copper pipes and other non ferrous metal up to 38mm (1 1⁄2 in.) deep

Finds rebar (ferrous metal) in concrete up to 76mm (3 inches) deep

Metal Detection Depth 150 mm Cable Detection Depth 150 mmStud Detection Depth 150 mm

Patented technology locates the centre and edges of wood or metal studs behind

non metallic walls, floors, or ceilings

CenterVision� Technology finds the stud centre in one pass

Backlit LCD screen with easy-to-understand on-screen graphics and audio signal

indicate target

Dual-sensitivity scanning—Normal mode up to 19mm ( 3/4 in.) or DeepScan� up

to 38mm (1 1/2 in.)

Finds copper pipes and other non ferrous metal up to 38mm (1 1/2 in.) deep

Finds rebar (ferrous metal) in concrete up to 76mm (3 inches) deep

Turn off wood and metal-scan to trace unshielded energised electrical

conductors, even in plastic conduit

Patented SpotLite� Pointing System shines a bright beam of light over target

Locates the edges of studs or joists through drywall and other

common wall materials to a maximum depth of 3/4" (19mm)

Audio and visual indication of stud edge detection

Automatic calibration switch

Durable ABS case

Automatic shut-off for longer battery life

Pocket size for easy storage

± 1/8" (3mm) wood stud centre detection accuracy

With Non-Trip Loop Impedance Check

Finds metal pipes and grids/bars, conduit or metal studs/joists up to 15cm (6in.)

deep

Pinpoints the location and depth of metal rebar and pipes

Readings in inches and centimetres

Automatic differentiation between steel and copper pipe (or any magnetic vs

non-magnetic metal)

Dual display LCD

One touch operation

Requires 9V PP3 battery (stock no. 394-9059)

The only safe solution for socket testing, as it varifies that the earth is

connected and indicates the quality of the earth connection. The T-Safe�

technology gives earth loop impedance checking without tripping 30mA

rated RCDs

13A mains socket tester

3 red/green LEDs indicate 6 loop impedance ranges (±10%): 0 - 1.7Ω, 1.7 -

5Ω; 5 - 10Ω; 10 - 100Ω; 100 - 200Ω; 200 - 500Ω

3 red/green LEDs indicates wiring good plus wiring fault conditions: P-N

reverse, P-E reverse, P fault, N open, E open

±1/4" (6mm) metal stud centre detection accuracy

Batteries are not included

Pinpoint accuracy provided by automatic sensitivity and conical sensor

housing

Detects even through damp plaster or foil backed plaster board

Compensates against extraneous influences such as metal-work in close

proximity or stray electromagnetic fields

Headphone socket provided for use in high noise environments

Requires 1 x PP3 9V battery (stock No. 394-9059)

centre

Continuous AC detection of unshielded energised electrical conductors between 90 to 250V to a

typical depth of 50mm (2 inches) for safety

Stock no. Price per OM S$ S$ S$

687-6162a unit 1+ 1244·00

Requires one 9V PP3 battery (typical stock no. 394-9059) not supplied

into a live socket, three neons lit up indicate correct wiring, whilst

one or more neons failing to light indicate wiring errors.

Select AC-SCAN to locate & trace unshielded energised electrical conductors, even in plastic

conduit

Patented SpotLite� Pointing System shines a bright beam of light over target centre

Integrated, erasable marker allows for one-handed operation.

Continuous AC detection of unshielded energised electrical conductors between 90 to 250V to a

typical depth of 50mm (2 inches) for safety

Requires one 9V PP3 battery (typical stock no. 394-9059) not supplied

Also indicates undervoltage (<195V) and overvoltage (>270V) conditions

Overvoltage Category: CAT II, 300 V

Ideal for testing 13A sockets

Three neons show wiring status

Flame retardant ABS casing

Metal Detection Depth 150 mm Width (mm) 109 Automatic Calibration Yes Depth (mm) 63 Height (mm) 251 Weight 286 g

Manu. Part No. Stock no. Price per OM S$ S$ S$

77-110 516-9429 unit 1+ 24·80

Metal Detection Depth 76 mm Cable Detection Depth 50 mmStud Detection Depth 38 mm Live ac Conductor Indication Yes

Metal Detection Depth 38 mm Cable Detection Depth 50 mmStud Detection Depth 38 mm Live ac Conductor Indication Yes

Supplied with: full instructions.

Metal Detection Depth 38 mm Stud Detection Depth 38 mmCable Detection Depth 50 mm

Stock no. Price per OM S$ S$ S$

418-369 unit 1+ 107·50

Voltage 240 V ac Earth Loop Impedance Test No Wiring Checked Yes

Stock no. Price per OM S$ S$ S$

418-363 unit 1+ 76·00

Stock no. Price per OM S$ S$ S$

418-379 unit 1+ 154·00

Twin and Earth cable detection depth 1.0 - 2.5 mm2

4.0 - 10 mm2

16 mm2

12 mm typ.25 mm typ.25 mm

Telephone & computer cable detection depth To a depth of 16 mm or better Operating temperature -5 °C → +40 °C Dimensions 50 x 64 x 30 mm Weight 190 g

Note: High sensitivity RCDs or excessive earth leakage currents may cause inadvertent tripping of the

circuit. Always check prior to use where loss of supply may be hazardous or unacceptable.

This unit is an indicator only and is not designed to provide readings for completing certificates

Stock no. Price per OM S$ S$ S$

418-353 unit 1+ 380·00

Stock no. Price per OM S$ S$ S$

255-676 unit 1+ 187·00

Voltage 230 V ac Earth Loop Impedance Test Yes Wiring Checked Yes Audible Tone No

Stock no. Price per OM S$ S$ S$

719-0885S unit 1+ 37·70

Stock no. Price per OM S$ S$ S$

719-0901S unit 1+ 154·00

2269

www.nguyenxuong.com

Page 35: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Aus/NZ Socket Testers

Phase Rotation Testers

Voltage Level Indicators

BS4343 Mains Socket Testers

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple a New product to range

SOK 40 (2P & E)

Safety Plugs

Fluke 9040

Fluke 9062

Phase Rotation & ContinuityIndicator Martindale PC15250

3-phase industrial check plugwith Martindale phase rotationPC101

A range of voltage testers each available in versions suitable for electronic or electrical applications.

Buzz-IT Check Plug with SounderMartindale BZ101

16A Industrial Check PlugsMartindale CP201 & CP301

SOK 36

16A BS 4343 3 pin (2P+E) socket tester for testing 240V systems.

Manufactured from clear impact resistant PVC, the RS Australian and

New Zealand plug-in mains socket tester is designed to ensure

personal and equipment safety.

Motor rotation and rotary field indicator with contact-free detection

Indication of the three phases via LCD

Indication of the phase rotation direction via LCD

Swift determination of the phase sequence in three-phase networks

Voltage and frequency range suitable for industrial systems

LC-display with good visibility in bright areas (i.e. outdoor)

Fused test probes (500mA 1000V fast acting)

Logical green for go indication shows good wiring status - 3 green

LEDs indicate good wiring status

Detects 18 faulty wiring condition

Continuous audible tone indicates correct wiring

Strong warbling tone indicates incorrect wiring

Audible fuse finding facility

This indicator will prove continuity, or identify fault condition, of all

Socket TesterThe green neon will light if the socket tested is wired correctly. The

For 3-phase socket outlets, this indicator will instantly verify connection,

or identify non-connection, of all three lines and shows the sequence of

phase rotation. To ensure the correct and safe operation of 3-phase plant

with motors turning in the expected direction, it is fitted with a red 16 A, 4-

pin, 3-phase and earth BS4343 plug.

As with the Martindale classic check plug, this is a fast and easy way

to test 13A sockets. Also incorporates audible indication of correct

wiring for hard-to-locate sockets and can be used as a basic fuse

finder.

Rotary field Indicator – indication of the three phases via LED

Motor rotation Indicator - display of motor rotation direction

Contact free determination of the rotation direction of running motors

Swift determination of the rotary field as for conventional rotary field indicators

Magnetic field detection to detect AC solenoid valve

Contact-free determination of rotation direction of running motors.

Ideal if motor shafts are not visible or difficult to access. (i.e. circulating pumps)

Voltage free and safe detection of three phase motor connectors .

Indicates the motor rotation before starting the motor

Fused test probes are 500mA 1000V fast acting

three lines and shows the sequence of phase rotation. It&#146;s a fast, effective

method of identifying worn or unmarked cables and ensures 3-phase outlets and

machines are wired correctly.The retractable GS38 probe shields give a choice of

long, exposed tips for inaccessible contacts or safer, shorter lengths for

increased safety.

Fast and safe indication of socket wiring

Three neons show wiring status

Incorporates audible indication of correct wiring

Fuse and trip finding, located when buzzer stops

Flame retardant ABS housing

The simplest, safest and most efficient

method of checking 16A 2P+E BS4343

sockets

Intended for use on industrial 240V

sockets whilst the 110V check plug will

check centre tapped 110V supplies

Both the 110V and the 240V Check

Plug are fitted with a standard BS4343

orange neon will light if there is a fault, i.e. missing earth or reversed polarity.

Contact RS for calibration requirements

With Non-Trip Earth Loop Impedance, Polarity

& RCD check

Indications include:

Supplied with: key/belt ring.

Voltage 240 V ac Earth Loop Impedance Test No Wiring Checked Yes Audible Tone Yes

16A plug

Fault conditions displayed on three neons on the 240V checker and on three LEDs on the 110V unit

Both Check Plugs list fault conditions and their associated indications on the face of the unit

Supplied with: 4-pin 16 A plug, instructions

Live - earth reverse

Live - neutral reverse

Faulty, neutral, earth and live

Missing live

Weight 200 g

Operational check of 30mA RCDs

Supplied with: 3 fused test probes, 3 crocodile clips, instruction

manual.

Overvoltage Cat. CAT III 600V Voltage Range 100 to 600 VFrequency Range 40 to 60Hz

Contact RS for calibration requirements

Stock no. Price per OM S$ S$ S$

719-0891S unit 1+ 48·90

Tests for total supply system polarity safety

Bright LED’s indicators with logical Green for Go LED Indication

Detects good plus 17 wiring fault conditions

Clear indication of where the actual fault is - Live, Earth or

Neutral

Continuous or strong warbling tone gives positive quick

indication of good or faulty wiring

Colour LED read out shows earth loop impedance result as

Good, Check or Urgent Check; Good when less than 1.8Ω

Built-in self check

Approvals: Australian Standards Approval number CS900020.

Supplied with: One fused crocodile clip, two fused prods with retractable GS38

shrouds, instructions

Voltage Range 40 to 700 V Measurementcategory

CAT III, 600 V / CAT IV,300V

CurrentConsumption

approx. 1 mA @ 700 V Safety Complyingwith

IEC61010 / EN61010,IEC61557-7 / EN61557-7

Frequency Range 15 to 400 Hz

SOK ADP40 Converts S0K40/16 into a 32A tester

16A socket to 32A plug

Stock no. Price per OM S$ S$ S$

254-308S unit 1+ 165·00

Note: High sensitivity RCDs or excessive earth leakage currents may

cause inadvertent tripping of the circuit during loop check. Always

Stock no. Price per OM S$ S$ S$

467-4964 unit 1+ 80·00

Stock no. Price per OM S$ S$ S$

424-585S unit 1+ 220·00

Stock no. Price per OM S$ S$ S$

780-059 unit 1+ 35·90

Pins 3 Wiring Checked Yes Audible Tone No

Description Stock no. Price per OM S$ S$ S$

Fluke 9040 513-1828S unit 1+ 467·00

1000V 500 mA Fuse 388-4132 unit 3+ 5·30

check prior to use where loss of supply may be hazardous or unacceptable.

This unit is an indicator only and is not designed to provide readings for completing certificates

Supplied with: 3 Fused test probes, 3 pc Crocodile clips,3 pc Test leads 9 V PP3 battery, Protective

Holster and Instruction manual

Description Stock no. Price per OM S$ S$ S$

240V - Blue plug CP201 253-535S unit 1+ 53·50

110V - Yellow plug CP301 253-541S unit 1+ 72·00

Voltage 230V

Wiring Checked Yes

Earth Loop Impedance Test Yes

30mA RCD test Yes

Polarity Test Yes

Audible Tone Yes

Voltage Range 1400 Vac Measurement category CAT III / 300 V Phase Display 120 - 440 Vac Protection Degree IP 40 Frequency range 2400 Hz Safety Complying with IEC61010 / EN61010, IEC61557-7 / EN61557-7 Test Currents < 3.5 mA

Description Stock no. Price per OM S$ S$ S$

Fluke 9062 513-1834S unit 1+ 340·00

1000V 500 mA Fuse 388-4132 unit 3+ 5·30

Description Stock no. Price per OM S$ S$ S$

SOK 36 704-7747a unit 1+ 126·00

2270

www.nguyenxuong.com

Page 36: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Dig. Readout Volt Level Indicator

Mains Voltage Indicators- Contact

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

New products available online every week

Fluke T100 Series Voltage and ContinuityTesters

Combicheck 1.3 6-690V AC/DC

240V Proving Unit for Neon VoltageIndicators

Digicheck 3.2

Fluke T120 & T140 LCD Display,12 to 690VAC/DC

Filament Test Lamps Drummond MTL7and MTL9C

Safety Voltage IndicatorMartindale VI13700

Mastercheck 3.2 6-400V AC/DC

Voltage testers with or without resistance measurement facility

An essential safety aid that is widely specified by training

LED voltage Indication

Illuminated test probe

Continuity testing with audible buzzer for continuity and voltage

Phase sequence testing

>90Vac Single Phase Test

Line powered LED indicates 50V-120Vac/dc even without batteries

Supplied with 2 x AAA batteries 591-657 (upto 1500 hours operation)

IP50 enclosure

Safety approved in accordance to EN61243-3 and VDE 0682 Part 401

A handheld, battery powered proving unit able to provide a nominal 240Vdc,

2mA source to prove the integrity of neon type test voltage indicators

For safety, voltage indicators should be checked for correct operation from

this known voltage source before and after every use

The unit is housed in a compact ABS plastic case and fitted with a belt clip for

convenience

An LED is used to indicate battery condition

Digi check 3.2 with AC/DC range and continuity test on a 2000 count LCD

display, with back light.

2-pole tester with LED

12 to 690V a.c./d.c voltage indication range

Diode/ Continuity test with visual and acoustical indication

Integrated single pole test for phase detection

Rotary field indication

IP65-water-jet and dust-tight protection for outdoor use

Electrical torch function for working in dark environments

Automatic, internal load for tripping out 30mA RCD’s

Quick response time (<0.1s) for fast voltage tests

Battery test function

Probe-tip protection permanently attached to lead

Complies with GS38 with regard to probe tip construction (less than 2mm of exposed

metal tip)

Fully operational voltage indication even when batteries are discharged or when no

Two filament test lamps giving safe indication of voltages

between 150V and 500Vac/dc. Their robust design meets the

recommendations of the Health and Safety Executive in

their guidance notes on electrician’s test lamps (GS38)

LED voltage Indication

Line powered LED indicates 50 to 120Vac/dc even without batteries

2 pole tester with LED and 3½ digit LCD 1999 count display

12 to 690V ac/dc voltage indication range

Diode/continuity test with visual and acoustic indication

Integrated single pole test for phase detection

Rotary field indication

IP65 protection for outdoor use

Integral torch

Automatic, internal load for tripping out 30mA RCDs

Quick response time (<0.1s) for fast voltage tests

Battery test function

Probe-tip protection permanently attached to lead

Stock no. Price per OM S$ S$ S$

481-2116 unit 1+ 83·50

0 to 100Hz (ac >2Hz) frequency range

IP50 enclosure

Safety approved in accordance to EN61243-3 & VDE 0682 Part 401

Supplied with 2 x AAA batteries (upto 1500 hours operation), see RS Stock

no. 591-657)

Automatic range selection

Illuminated measuring probes

Audible buzzer on continuity test

Display hold function

Polarity (+/-) check

Single pole phase testing

Transistor check

Battery Low indicator

Battery and function test

batteries are fitted

Complies with EN61243-3 and EN61010-1

Input protection to EN61010-1 CAT IV 600V

Note: This product will only work with test voltage indicators that have an input

impedance of greater than 120kΩ.

organisations, utilities and large contractors. This GS38 compliant voltage indicator

rapidly and safely checks if a circuit is live, its voltage range and AC and DC voltages

from 50V to 600V.

Tough, moulded case

Double insulated leads

Probe tip contains finger guard and lockable, retractable prod sheath

Probe incorporates a 500mA HRC fuse

Stock no. Price per OM S$ S$ S$

242-4111S unit 1+ 146·50

Automatic on/off to save battery life

Norm: VDE 0682 part 401 / EN/IEC 61234-3

Electrical version complies to HSE GS38 recommendation with less

Complies with GS38 with regard to probe tip construction (less than 2mm of exposed metal tip)

Fully operational voltage indication even when batteries are discharged or when no batteries are

fitted

Complies with EN61243-3 and EN61010-1

Input protection to EN61010-1 CAT IV 600V

Resistance measurement up to 1999Ω (T140 only)

Backlight (T140 only)

Contact RS for calibration requirements

Input Current Is <2.5mA at 690V Input Impedance ≥300 kΩVoltage Surge Proof 6kV Continuity Check Yes Voltage Range 6 → 690 Vac/Vdc Frequency Range 0 → 100 Display Type LED

than 4mm of exposed metal tip

Standard version has probes with 15mm exposed tips

Powered by 2 x AAA batteries (not supplied)

Surge proof to 6kV

Contact RS for calibration requirements

Input current Is <2.5mA at 400V Input Impedance 265 kΩVoltage surge proof 4kV Continuity Check Yes Voltage Range 6 → 400 Vac/dc Resistance RangesDisplay Type LED Frequency Range 0 → 100 Hz

Supplied with: Instruction leaflet & batteries.

Stock no. Price per OM S$ S$ S$

621-1155S unit 1+ 116·00

Supplied with: Instruction leaflet & batteries

Supplied with: Instruction manual.

Stock no. Price per OM S$ S$ S$

410-0104S unit 1+ 66·50

Display 12, 24, 50, 120, 230, 400, 690V LED bargraph Continuity range 0 → 400kΩVoltage range accuracy ±(3% rdg +3 digit) Power supply 2 x AAA (IEC LR03) supplied Continuity/ Diode test Optical (LED) / acoustical Operating Frequency 0 - 400 Hz

Supplied with: Operating instructions.

Description Stock no. Price per OM S$ S$ S$

T100 502-5694S unit 1+ 564·00

T100, Aus version 516-6290 unit 1+ 110·50

Voltage Range 0 to 600 V Continuity Check No Display Type LED

Voltage Range 5 to 690 Vac/dc Continuity Range 0 to 500 Input Impedance >600 kΩ Display Type LCD

Display 3½ digit LCD , 1999 count and 12, 24, 50, 120, 230, 400, 690V LED bargraph Voltage range accuracy ±(3% rdg +3 digit) Operating frequency 0 to 400Hz Resistance Measurement Up to 1999Ω (T140 only) Continuity/ Diode test Optical (LED) /acoustic Continuity range 0 to 400kΩPower supply 2 x AAA (IEC LR03) supplied

Accessories

Stock no. Price per OM S$ S$ S$

719-0882S unit 1+ 118·00

Stock no. Price per OM S$ S$ S$

493-4200 unit 1+ 230·00

Description Stock no. Price per OM S$ S$ S$

T120 502-5701S unit 1+ 172·00

T120 516-6307 unit 1+ 195·50

T140 721-5385S unit 1+ 240·00

T140 516-6313 unit 1+ 224·00

C33 Carry Case 502-5723 unit 1+ 49·90

Description Stock no. Price per OM S$ S$ S$

C33 Carry Case 502-5723 unit 1+ 49·90

TP38 Slender Probes 384-8265 unit 1+ 28·80

AC285 Large Alligator Clips 451-1431 unit 1+ 36·40

AC220 Alligator Clips 449-9915 unit 1+ 61·40

2271

www.nguyenxuong.com

Page 37: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Voltsticks- Non Contact

Mains Test Screwdrivers

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple

Mains Test Screwdriver

VDE Insulated

Volt-Stick AC Indicator

Volt-Stick AC Indicator, Intrinsically-Safe

Volt-Stick PRO Selective AC Indicator

Volt-Stick SOUND AC Indicator with audible alarm

EPF 30 Professional Easy PhaseFinder 50-400Vac 50/60Hz

Proving Unit Martindale PD690

The Volt Stick SOUND is a pen style non contact AC voltage

indicator for safely checking the presence of an AC voltage in

cables, wall sockets, fuses junction boxes etc. No current flow

A single pole voltage detector that does not require the user

to operate touch pads or any direct contact device. The EPF30

overcomes the limitation of non contact phase-live detectors

whereby under OPEN CIRCUIT parallel conductor conditions

conventional testers may give false indication of a live

The Volt Stick PRO, is a pen style non contact AC voltage

indicator for safely checking the presence of an AC voltage in

cables, junction boxes etc. The patented forked tip design has

unsurpassed selectivity. This is because the maximum

sensitivity is between the two prongs of the fork. Outside the

is needed for correct operation.

Ingenious pocket devices for determining the presence of

50Hz AC voltages. They are battery powered pen style units

with nylon tips that glow red when a voltage is detected.

There is no necessity for contact or for current to be flowing

in order to activate the unit. Ideal for finding breaks in power

cables, checking plug wiring, checking fuses, distinguishing

between live and neutral wires, determining live cables in

junction boxes, finding faulty switches, locating the faulty

lamp in a series, and many more.

Battery powered proving unit, essential for safe use of voltage

indicators and test lamps.

High quality VDE mains testing screwdriver manufactured to

DIN57860 Part 6 and VDE0680/6, suitable for use on

150V-250V. Screwdriver incorporates a neon indicator and is

sealed to prevent tampering. Blade tips are hardened and

blackened chrome-vanadium steel.

conductor.

Overall Length 146 mmBlade Dimensions 60 x 3 mm

fork the sensitivity is low, so external interference fields have small effect.

230V: range 220 to 400Vac (with respect to ground

potential). The sensitivity is optimised for detecting 230V

50Hz mains voltages.

Approved for use in hazardous areas, the

intrinsically safe Volt stick has all the features of

the standard 230V version with voltage

measuring range 230 to 1000V 50Hz (with

respect to ground potential).,Applications for

the volt stick include finding breaks in power

cables, checking plug wiring, checking fuses,

Test voltage indicators with ranges above 240V

690V (nominal) @ 0.5mA high output voltage source

Designed for use with Drummond and other similar lower resistance test

lamps, having sufficient output to cause illumination

Neon indicates battery condition

Single probe operation, allows for non-contact voltage tester proving

(access 5mm)

Operates test voltage indicators that have greater than 4kΩ internal

resistance

6 x AA batteries (required, see stock no. 591-225), maintain output

voltage for extended testing.

143 x 83 x 50mm, (H x W x D) Wt. 300g

Tip glows red and the audible sounder activates when a voltage is detected.

Locates breaks in cables

Detects blown fuses inside plugs or fuse holders

Distinguish between live and neutral wires in both single and three-phase supplies

Identifies voltage-carrying cables in junction boxes

Identifies faulty in-line switches

Locates faulty lamps in series connections

Complies with IEC 61010-1 CAT III 1000V

Mains tester/screwdrivers with internal neon and

series resistor to enable use on 220-250Vac mains.

Clear plastic moulding with extension over chrome-

vanadium screwdriver shaft. Smaller version is fitted

with metal pocket clip. Conductive plastic finger

Powerful red light in the tip glows when a voltage is detected

High selectivity reduces the risk of spurious indications for better indication of live cables in

crowded cable runs

Slide in tip adapter is supplied to reduce the selectivity where larger cables and fuses need to be

checked

Live cables can easily be detected in equipment cabinets, fuse boxes etc

Extremely safe when measuring in junction boxes

Fully insulated for safe use

Supplied with clip in shunt for use as conventional low selectivity indicator

Complies with IEC 61010-1 CAT III 1000V

Stock no. Price per OM S$ S$ S$

719-0894S unit 1+ 232·00

Stock no. Price per OM S$ S$ S$

828-022 unit 1+ 10·50

contact.

True phase locator scanning technology determines the strongest true voltage and eliminates false

signal indication

Can identify the true live phase conductor amongst a bundle of open circuit conductors

Bright LEDs plus continuous audible tone gives clear indication from dim to bright conditions

50 to 400Vac 50/60Hz operating range

Rugged construction with finger guard configuration for safe operation

Drop proof from 2 metres

Built in self test to indicate correct operation

Powered by PP3 battery (not supplied, see stock no. 394-9059)

3 minute auto power offdistinguishing between live and neutral wires, determining live cables in junction boxes, finding faulty

switches, locating the faulty lamp in a series, and many more. This handy instrument will prove

invaluable in saving time when troubleshooting.

110V: range 90 to 400Vac (with respect to ground potential). The sensitivity is optimised for detecting

110V 50Hz voltages as found in factory and other industrial applications.

Supplied with: 2 AAA batteries & instructions

Description Overall Length (mm) Blade Dimensions (mm) Stock no.

Small Test Screwdriver 134 60 x 3 544-853

Large Test Screwdriver 196 108 x 3.5 549-448

Supplied with: Nylon carry case with belt loop and instructions.

Note: Will NOT detect cables behind buried plaster, buried trunking etc. and will not detect output

from safety isolation transformers with earthed secondary centre tap. The unit should be checked for

correct operation using a known voltage before use.

Supplied with: 2 x AAA batteries and instructions.

Group & Category: II 2 G EEx ib IIC T4

Stock no. Price per OM S$ S$ S$

719-3017S unit 1+ 84·00

Description Stock no. Price per OM S$ S$ S$

Small Test Screwdriver 544-853 unit 1+ 1·50

Large Test Screwdriver 549-448 unit 1+ 1·90

110V model 230V model

Power supply 2 x 1.5V AAA alkaline batteries (supplied)

Sensitivity (50Hz) 230 VAC Operating temp: -10 °C → +50 °C Power supply: 2 x AAA (LR03) batteries Dimensions & weight 146 mm x Ø max 22mm : 40g

Sensitivity (50Hz∼) illuminate at 4mm from wire 90V 220V Temperature -20 → +50 °C Response Instantaneous

Forked tip cable capacity 4.5mm diameter Operating temperature -20 °C → +50 °C Operating frequency 50Hz Over-voltage CAT III 1000V Power Two AAA (LR03) batteries (supplied)

Power supply 2 x 1.5V AAA alkaline batteries (supplied) Sensitivity (50Hz∼) illuminate at 4mm from wire 220V Operating temperature -20 → +50 °C Response instantaneous

Description Stock no. Price per OM S$ S$ S$

Volt-Stick Indicator 230V 214-467 unit 1+ 42·90

Volt-Stick Indicator 110V 238-3571 unit 1+ 42·90

Stock no. Price per OM S$ S$ S$

167-645 unit 1+ 39·30

Voltage Range (V(ac)) Stock no. Price per OM S$ S$ S$

110 – 1000 166-816 unit 1+ 58·50

230 – 1000 166-838 unit 1+ 58·50

Description Stock no. Price

per

OM S$ S$ S$

Intrinsically Safe Volt-Stick(ATEX)

457-8327 unit 1+ 98·00

Intrinsically Safe Volt-Stick(IECex)

166-822 unit 1+ 72·00

2272

www.nguyenxuong.com

Page 38: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Automotive Voltage Indicators

Magnet Sticks Non-Contact

Cable Tracing

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Many more leading brands from over 2,500 suppliers available online

Car Voltage Tester

Non-Contact Voltage andMagnetic Indicator MartindaleTEK200

Unitest MAGNO-VOLTfix

Magnetic Field Indicator / Solenoid Tester

Intrinsically-Safe Magnetic Field Indicator

PTS100/200 - Pair Tracing Kit

LVD2 Volt Light

Non-contact AC voltage detector and LEDflashlight

Fluke 1AC Voltage Detector

Tester for automobile electric and electronic circuits. Its low

power consumption of 1.5mA is suitable for locating faults

in electronic components where conventional lamp testers

may cause damage. It has a crocodile clip on one end, and a

tester with LED display and probe tip. The bright LED display

indicates voltage and polarity. Particularly suitable for

trouble shooting in wiring harnesses with catch hook to

reach any wire and a pricking needle to probe through the

insulation.

Fluke VoltAlert� - Suitable for non contact detection of AC

voltage from 90 to 1000Vac.

The next generation VoltAlert� AC non-contact voltage

testers from Fluke are easy to use — just touch the tip to a

The tip of the Magnet Stick lights up when in the presence of

a magnetic field. It responds to all kinds of magnetic fields

from alternating current to direct current and permanent

strong magnets.,A small test magnet is housed in the cap of

the Magnet Stick to check that it is working correctly.

Contact-free, optic and acoustic detection of AC voltages

Magnetic field detection

Precise detection of line interruptions in open installed

cables

Compact, pen style construction

H.140 W.24 D.20mm Wt. 50g

Bright white flashlight illuminates working area

Blue indicator means you’re close

Red indicator means you’re at the source

Detects voltage from 40Vac to 300Vac upwards

Comes with versatile clip to secure light to a pocket, hat or even a

panel door

Operating temperature 0 °C → +50 °C

Ultra bright white LED with 100000 hour bulb life

AAA battery included"

Non-contact AC voltage detector and LED flashlight

combined into one easy to use pen-style design. The LVD2

is a CAT IV 600 V rated non-contact detector that is suitable

for commercial and industrial applications. The LVD2

includes dual sensitivity indication, showing blue when 1”

to 5” (2.54 cm to 12.7 cm) from the source and turning red

when at the source.

The PTS Pair Tracing System comprises the PTS 200 Tone

Generator and the PTS 100 Probe in a woven polyester

carrying pouch. The System is designed to provide an easy

to use and cost effective means of tracing wire pairs

A non-contact voltage indicator with the additional ability to

detect magnetic fields.,Suitable for indicating the operation

of solenoid valves in pneumatic and hydraulic control

equipment, and testing relays or solenoids in a wide range

of vehicle and machine controls.

Input voltage 3-48Vac/dc Voltage display 2 LEDs

Standards: CAT IV 600 V

Approved for use in hazardous areas

The tip of the intrinsically safe magnet stick

lights up in the presence of a magnetic field

Responds to all kinds of magnetic field from

alternating current and direct current and

permanent strong magnets

Fast, Accurate Wire Identification

Sends Tone to Identify Wires

Polarity Indication

Continuity Test

Adjustable Volume Control

Easy to Operate

2-Line Modular Test Lead

Note: This unit uses a magnetic read switch sensor. For applications requiring more sensitivity we

recommend stock No. 254-099 which uses a Hall Effect sensor.

terminal strip, outlet, or supply cord. When the tip glows red and the unit beeps, you know there’s

voltage present. Electricians, maintenance, service, safety personnel, and homeowners can quickly test

for energized circuits in the workplace or at home.

Display 2 LEDs Safety IEC 1010, EN 61010 Voltage Range 50 to 600Vac Overvoltage Cat. CAT III/600V Frequency Range 50 to 500Hz Pollution Degree 2Magnetic Sensitivity >25mT Power Supply 2 x AAA (IEC LR03) supplied

Stock no. Price per OM S$ S$ S$

225-3335 unit 1+ 32·40

Avoids the need for a separate proving unit

Tests relays, contactors and solenoids without

Stock no. Price per OM S$ S$ S$

493-3241 unit 1+ 43·40

Supplied with: AAA battery

Supplied with: Batteries fitted and an instruction leaflet.

Stock no. Price per OM S$ S$ S$

374-1849 unit 1+ 122·50

Supplied with: 2 x AAA alkaline batteries (stock No. 591-657) and integral test magnet.

Rugged Industrial design

Water Resistant

disconnecting them from circuit

Senses AC voltages from 100 to 600V by detecting the electrical field

Determines and displays polarity of magnetic fields

Self test facility ensures correct functioning

The self test circuit transmits a 50 Hz signal to the voltage or magnetic sensor to fully test the

integrity of the internal circuitry

Powered by PP3 battery (stock No. 394-9059)

Tip glows red when a voltage is detected

Pocket sized

Batteries included

Description Stock no. Price per OM

Fluke 1AC Voltage Detector 462-8545 unit 1+ 48·00

Fluke 1AC-II Voltage Detector 255-073 unit 1+ 48·30

PTS 200 Tone Generator:

Voltage Range 100V to 600Vac 3 mm at 110Vac 50Hz Voltage SensitivityDistance from a flat PVC 1 mm<sup>2</

sup>

twin and earth cable suspended in freespace:

23 mm at 240Vac 50Hz

Voltage IndicationRed LED and audible tone (3 kHz) in thepresence of an AC voltageGreen LED internal battery condition

Green LED south pole

Frequency Range 50Hz to 50kHz (voltage) Frequency Range 0 to 50kHz (magnetic) MagneticSensitivity

±10 mT Operating Temp. -5 → +40 °C

MagneticIndication

Red LED north pole Case Material ABS

Group & Category: II 2 G EEx ib IIC T4

Stock no. Price per OM S$ S$ S$

255-061 unit 1+ 60·90

Stock no. Price per OM S$ S$ S$

375-5422 unit 1+ 62·50

Stock no. Price per OM S$ S$ S$

719-0876S unit 1+ 117·00

Description Stock no. Price per OM S$ S$ S$

Magnetic field indicator, ATEX 457-8311 unit 1+ 101·50

Magnetic field indicator, IECEx 166-800 unit 1+ 96·00

The PTS 200 may be connected via the modular plug or the crocodile clips to the pair under test.

Depending on the switch position the Tone Generator will test Polarity continuity or short circuits.

The PTS 200 can be used on twisted pair wiring (Telecom, Datacom, security / alarm, audio and

electrical), single conductors, coaxial cables, de-energized AC wiring and just about any other

wiring you can think of.

PTS 100 Probe:The PTS 100 Probe has a built-in loudspeaker to make it easy to hear the tracing signals and a near/

far sensitivity Adjustment to allow both broad searches and pinpoint identification of wires. To

operate just press the button on the top and adjust the sensitivity control to hear the tone

generated by the PTS 200

Note: Only for use on non-powered cables, powered by PP3 batteries (not supplied).

Image for illustration purposes only

Description Stock no. Price

per

OM S$ S$ S$

PTS100/200 Pair Tracing Kit,BTPlug

268-357 unit 1+ 152·00

PTS100/200 Pair Tracing Kit, RJ11Plug

331-5226 unit 1+ 129·00

2273

www.nguyenxuong.com

Page 39: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Cable Fault Finders

LAN Test Equipment

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple a New product to range

Pro3000 Analog Tone andProbe Kit

701k Classic Tone and Probe Kit

Fluke TS90 & TS100

IntelliTone Probes

TES-48

540 Tone Generator and InductiveSpeaker Probe

IntelliTone Kits

The Model 701K is recognised by technicians as the industry

standard for wire and cable identification. The kit is used for

the identification of single conductors or cables within a

bundle, at a cross connect point or at remote ends. Supplied

in a sturdy woven polyester carrying case the 701K kit

comprises the 77HP High Power Tone Generator and the 200

EP Inductive Amplifier

IntelliTone� digital signal locating technology is the smarter,

faster way to locate all hidden and hard-to-find cables. LED and

Designed to make cable identification and connector tracing easier.

Rugged, battery operated, handheld LAN tester to identify cable failures

UTP, FTP and coax cabling tests

Category 5 cabling

End to end EIA/TIA 568 verification

Detects opens, shorts, mis-wires, crossed pairs, reversals and split pairs

Distance to fault location

Measures cabling length

One button test mode

Easy to read LCD display

Low battery and auto power off

99 data set memory

Identifies up to 8 different cables with cable identifiers

Can be used for cables between 1m and 350m

Faults detected: opens, shorts, reversed, crossed and split pair

Breakthrough IntelliTone� digital signal technology finds

cables other toners/probes can’t. Speeds cable location with

For toning and tracing wire on non-active networks and

specifically for identifying individual pairs with SmartTone�

technology. Angled bed-of-nails clips allow easy access to

individual wires and the RJ11 connector is ideal for use on

telephone jacks. The large loud speaker on the probe allows

you to hear through drywall, wood or other enclosures to find

wires quickly and easily. Tone signal can be sent up to 10

miles on most cables. External switch on generator allows

selection of solid or alternating tone options, indicated with

solid or flashing LEDs. Probe has adjustable volume dial

control and "quick-twist" tip for easy replacement.,Free spare

tip with "Pro3000 Tone and Probe Kit".

Fast, Accurate Wire Identification

Sends Tone to Identify Wires

Two Distinct Tone Signatures

Stock no. Price per OM S$ S$ S$

462-9267 unit 1+ 500·00

These easy-to-use testers are the

equivalent of a three-in-one tool

kit: a fault locator, a cable and

wire manager and a tone

generator with SmartTone�

technology.

advanced sensing modes. Simplified signal interpretation with smart LED

and audio indicators.

audio indicators simplify cable isolation. Works with all industry-standard tone generators.

Frequency 1000 HzTone Yes

Polarity Indication

Continuity Test

Talk Battery supply

Adjustable Volume Control

Visual and Signal Strength Indication

Large Speaker for Noisy Environments

Facility for Headset/Buttset connection

Choice of Metallic or Plastic Probe Tip

2-Line Modular Test Lead

3-Colour LED identifies AC Ring Voltage

Rugged Industrial Design

The tone Generator includes:

Rejects noise and false signals

Identifies and diagnoses POTS with multi-line Telco detect, polarity and

ring indication

Audible and visual signal indication simplifies cable location in noisy

environments

Diagnoses essential cable information with polarity, continuity, and talk

battery

Safely and effectively tones active networks

Additional probes can be ordered separately

Accessories

Rejects noise and false signals using IntelliTone� digital signal technology (with

Intellitone Toner)

Locates hard-to-find cables, even on active networks

Speeds cable isolation with thumbwheel controlled sensing modes

Simplifies signal interpretation with smart audio and LED signal indicators

Extended battery life with auto power-off

Description Stock no. Price per OM S$ S$ S$

Pro3000 Tone and Probe Kit 503-568 unit 1+ 150·50

Gain 26 dB Voltage Protection (continuity mode) 52V d.c. @ 600ΩTransmitter Power 7dB @ 600Ω Talk Battery 4.5V d.c @ 600ΩWeight Including Battery 170/140 g

Works on any multiple core

(2+) cable up to 760m (TS90)

or 914m (TS100)

Instantly measures distance to

open-circuit or any fault from

one end of any cable pair

Patented SmartTone� tone

generator positively identifies

RJ11 connector, RJ45 jack and pair of alligator clips

pair

Measures cable distance on reel

Displays distance reading rather than waveform

Large LED screen

High voltage detection

Moisture-proof

One-button operation

Auto power-off after 5 minute disconnection

Validates twisted-pair installation with visual end-to-end cablemap (Intellitone 200 only

with toner)

The probe is directly compatible with Wavetek LT8000 Series LAN cable

tester’s tone generator function.

Stock no. Price per OM S$ S$ S$

370-5247 unit 1+ 235·00

In addition the IntelliTone 200 identifies, diagnoses, and troubleshoots

datacom/telecom services

The IntelliTone 200 also validates twisted-pair installation with visual

end-to-end cablemap

Supplied with: BNC to alligator clips adaptor

Description Stock no. Price

per

OM S$ S$ S$

IntelliTone 100Probe

513-6261 unit 1+ 155·00

IntelliTone 200Probe

513-6463 unit 1+ 196·00

For additional or replacement Intellitone Probes see 513-6261 & 513-6463

Traces end-to-end connections

Identifies and locates voice and data wiring and terminations

Sends and detects standard signals and checks continuity

LEDs provide visual indication of correct wire

Adjustable volume on probe

Rubber tipped probe will not break or crack

Standards: CAN/CSA-C22.2 No. 60950-1-03, CAN/CSA-C22.2 No. 1010.1-92, CSA-C22.2 No.1010.1B-97, UL/ANSI 3111-1

Description Stock no. Price per OM S$ S$ S$

IntelliTone 100 kit 513-6457 unit 1+ 275·00

IntelliTone 200 kit 513-6479 unit 1+ 375·00

Supplied with: PP3 9V batteries installed.

Input Protection 250 V rms ac, continuous or intermittent Impedance Range 35 Ω to 330 Ω with auto-compensation within this range. Maximum cable length TS90 2500 feet (760m), TS100 3000 feet (915m) Minimum length Minimum non-zero reading is 2 feet (0.6m) Representative maximum cable lengths 2500 feet: CAT-5 Twisted Pair

2000 feet: 12/2 ac Wire 1000 feet: RG-6/U TV Coax 500 feet (150m): RG-174/U Coax

Length Accuracy ±2 ft for cables < 10ft, ±5 ft for cables > 10 ft and < 200 ft, ± (3% rdg + 5 ft) for cables > 200 feet

High Voltage Detection Warning occurs for AC voltage > 5Vrms Measurement Rate Maximum of 4 complete measurements per second Measurement Technology Time Domain Reflectometry (TDR)

50 Ω drive impedance, 6 V maximum pulse height. VOP (Velocity of propogation) Adjustable from -20- to -99-, retained during power off.

Default to -66- when batteries are changed. Tone Injection Typically 1 kHz at an amplitude of 80% of battery voltage. Cable Type Virtually all two or more conductor cables Power 4 x AA alkaline battery, reverse polarity protected Low battery warning Indicator flashes when battery voltage falls below 4.1V Temperature Range - Operating 0 to 55°C (32 to 131°F) Temperature Range - Storage -40 to 70°C (-40 to 158°F) Size and Weight 188 x 70 x 38 mm, 450 g

Stock no. Price

per

OM S$ S$ S$

326-7694 unit 1+ 189·00

Description Stock no. Price per OM S$ S$ S$

Fluke TS90 543-352 unit 1+ 350·00

Fluke TS100 543-358 unit 1+ 540·00

2274

www.nguyenxuong.com

Page 40: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Visit our website for additional price information and exciting promotions

CableIQ Residential Qualifier

LinkRunner NetworkMultimeter

LinkRunner Pro NetworkMultimeter

LinkRunner Duo NetworkMultimeter

NetTool VoIP

MicroScanner2 Professional Kit

CableIQ Qualification Tester

LinkRunner Duo enables technicians to resolve a broader range

CableIQ Tester with remote adapter is a qualification tool

designed for network technicians who need to troubleshoot

connectivity problems and qualify cabling bandwidth.

LinkRunner Pro enables technicians to resolve a broader range

CableIQ is the first qualification tester designed for residential

installers who need to document that cabling systems are

installed properly and will perform reliably. It quickly qualifies

residential cabling systems to support voice, VoIP, 10/100/

1000 Ethernet and CATV and presents results in the form of

professional test reports. Designed especially with the

residential installer in mind, CableIQ is versatile and intuitive

enough to replace multiple tools for testing, ID-tagging and

troubleshooting all voice, data, video, audio and security

cabling.

Has all of the test capability of the MS2-100, but includes all

accessories in a single, preconfigured carry case.

Solve PC-to-network connectivity problems faster with NetTool.

See inline between the PC and network to quickly verify

Contents

connection speed, duplex, utilization, link configuration, health information

and network resources. View services offered, name, IP address and subnet.

Problem log alerts, duplicate IPs, unanswered DNS queries, TCP/IP

connection failures and more.

of today’s connectivity problems. Unlike traditional 10/100 link

testers, LinkRunner Pro verifies Gigabit link – increasingly important

for today’s high-performance networks. It also pings up to 10 key

devices, detects Power over Ethernet (PoE), resolves 802.1X security

conflicts, verifies cable wiremap, and identifies the nearest switch

port with Cisco, Extreme and IEEE Link Layer Discovery Protocols

(CDP/EDP/LLDP). Built-in IntelliTone digital toning precisely locates

cables at patch panels and switches. Link status reports can be

uploaded from USB port and routed with trouble tickets to expedite

problem resolution.

of today’s copper and fibre link connectivity problems. Unlike traditional 10/100

link testers, verifies Gigabit link – increasingly important for today’s high-

performance networks. It also pings up to 10 key devices, detects Power over

Ethernet (PoE), resolves 802.1X security conflicts, verifies cable wiremap, and

identifies the nearest switch port with Cisco, Extreme and IEEE Link Layer

Discovery Protocols (CDP/EDP/LLDP). Built-in IntelliTone digital toning precisely

locates cables at patch panels and switches. Link status reports can be uploaded

from USB port and routed with trouble tickets to expedite problem resolution.

Troubleshoots why existing cabling plant can’t support

the desired network bandwidth

Discovers what’s at the end of any cable and displays

device configuration (speed/duplex/pairing)

Frees-up switch ports and identifies unused links

Graphically maps wiring configuration and shows

distance to faults with Intelligent Wiremap

Tests all copper cabling media: twisted-pair, coax, and

audio cabling

Locates and traces cable with IntelliTone� digital

Documents that residential cabling systems are defect-free and TIA-570B compliant

Qualifies residential cabling systems to support voice, VoIP, 10/100/1000 Ethernet and CATV

Graphically maps wiring systems and shows distance to faults with built-in TDR

Tests and troubleshoots all low voltage residential wiring: coax cables, telephone wire, security

wire and speaker wire

Locates and traces cables with IntelliToneTM digital signalling technology (IntelliToneTM probe

available separately (stock no. 513-6261 or 513-6463)

Link at 10/100/Gig – identify device capabilities and confirm actual speed/

duplex status

Ping key devices – measure response of DHCP, router, DNS, and other

devices or URLs

Verify 802.1X settings – authenticate with EAP type, user name, certificates,

and password

Supplied with: CableIQ main unit (CQI 100), RJ45 patch cord (2), RJ11 patch cord (2), USB cable, bare

wire adaptor, speaker wire adaptor, coax cable, coax BNC adaptor, coax RCA adaptor, ’Qualified’ labels

(50), CD ROM user manual, getting started guide, AA batteries (4), soft carrying case.

Quickly solve PC-to-network connectivity problems on networks which

are active

Verify network drops; link connectivity, speed, duplex settings, finds

faults and cable length

Identify PC network configuration devices used and problems

Identify available network resources and services offered

Ping network devices using IP or DHCP

Download and print reports

Watch VoIP phones boot

Monitor VoIP phone and system performance

Validate QoS configuration

Log call control

Monitor call quality metrics

Detects opens, shorts and split pairs

LinkRunner�, the essential personal tool which lets

you quickly verify and troubleshoot network drops.

Identifies 10BASE-T, 100BASE-TX FDX/HDX, Token

Ring, Telco, Cable ID, un-powered PC or hub, Auto-

MDIX port. Cable tests: length, open, short, splits,

wiremap, crossed, straight through, plus tone.

Auto-negotiation and link verification via static IP

signaling technology

Link at 10/100/Gig – identify device capabilities and confirm actual

speed/duplex status

Ping key devices – measure response of DHCP, router, DNS, and

other devices or URLs

MicroScanner2 with main wiremap adapter

Remote identifiers #2-7

IntelliTone Pro 200 probe

Shielded twisted-pair RJ45 patch cord

RJ11 patch cord

Clip-set - RJ45 to 8 alligator clip test lead

Bare wire adapter

F Coax push on patch cord

Accessory soft pouch

2 x AA alkaline batteries

1 x 9V alkaline battery

Getting Started Guides

Owners CDs

Packaged in a deluxe Fluke Networks carry case.

Description Stock no. Price per OM S$ S$ S$

Cable identifiers 2,3,4 425-0798 unit 1+ 48·50

Description Stock no. Price per OM S$ S$ S$

NetTool VoIP 540-8285 unit 1+ 3730·00

Kit includes Cable IQ tester with remote adapter, IntelliTone 200 Probe, six remote IDs and rugged

carrying case

Detect PoE service – verify voltage level, and pairs to IEEE 802.3af specifications

Identify switch port – supports Cisco, Extreme, and IEEE Link Layer Discovery Protocols

Test cable wiremap – measure length; detect miswires, shorts, split pairs or opens

Locate and ID cable – use IntelliTone or optional IDs to locate cables at patch panels

Document results – upload link status reports with USB port for faster problem resolution

Verify 802.1X settings – authenticate with EAP type, user name, certificates, and password

Detect PoE service – verify voltage level, and pairs to IEEE 802.3af specifications

Identify switch port – supports Cisco, Extreme, and IEEE Link Layer Discovery Protocols

Test cable wiremap – measure length; detect miswires, shorts, split pairs or opens

Locate and ID cable – use IntelliTone or optional IDs to locate cables at patch panels

Document results – upload link status reports with USB port for faster problem resolution

address or DHCP. Includes LinkRunner� Wiremap Adaptor.

Stock no. Price per OM S$ S$ S$

369-554 1 kit 1+ 1750·00

UTP Yes STP Yes

Supplied with: LinkRunner Duo, Wireview Cable ID #1, LinkRunner Connect Software CD, USB cable,

RJ45 coupler, LinkRunner Duo getting started guide, four (4) AA alkaline batteries.

Description Stock no. Price

per

OM S$ S$ S$

Cable IQ tester withpouch

513-6435 unit 1+ 2150·00

Cable IQ Kit 513-6441 unit 1+ 2900·00

Description Stock no. Price

per

OM S$ S$ S$

LinkRunner Pro NetworkMultimeter

134-443 unit 1+ 1870·00

LinkRunner Pro Extended TestKit

134-419 1 kit 1+ 2820·00

Cable tests: length, open, short, splits, wiremap, crossed, straight

through

View Link, Length, Ping for each drop

Link: Check PC drops for connectivity, speed and duplex settings

Length: Checks cable configurations, finds faults and length

Ping: Verifies connectivity to key network resources and PC NIC

response

Stock no. Price per OM S$ S$ S$

624-7441 unit 1+ 2320·00

Manu. Part No. Stock no. Price per OM S$ S$ S$

LR DUO 672-7559 unit 1+ 2450·00

Description Stock no. Price per OM S$ S$ S$

Link Runner 513-6334 unit 1+ 840·00

Link Runner Test Kit 513-6340a unit 1+ 2055·00

RJ45 UTP 340-9624 unit 1+ 11·80 15+ 11·00 25+ 10·50

Accessories

Description Stock no. Price

per

OM S$ S$ S$

MS-SX Fibre SFP Trans.Module

672-7552 unit 1+ 325·00

MS-LX Fibre SFP Trans.Module

672-7556 unit 1+ 620·00

MS-FX Fibre SFP Trans.Module

672-7565 unit 1+ 800·00

2275

www.nguyenxuong.com

Page 41: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

IDC Cable Tester

Wiring Testers

PC Cable Checker

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple ➤ Indicates more pricing available online a New product to range

IDC Cable Tester

Network Cable Tester

Linkmaster

Shielded Type II

LAN Tester & Remote

RJ45/RJ11 Continuity

NetTool Series II

PC Cable Checker

A compact microprocessor controlled cable tester enabling

quick and reliable wiring configuration checks of cables

terminated with the most popular sizes of IDC connectors,

ranging from 10 way up to 64 way. This versatile cable tester

allows the user to identify a correctly made standard ribbon

cable or to carry out a rapid comparison test with a known

"good" custom made cable.

Data wiring tester consisting of master and remote units,

designed to check the integrity of 2, 3 and 4 pair voice and

data channels with a loop distance of up to 3048 metres.

Three jack sockets are incorporated into each half to enable

8 way RJ45 USOC, 568A and 568B sequences to be checked.

Sockets are fully shielded enabling the testing of both UTP

and STP/FTP wiring systems.

A compact and portable, versatile cable tester that quickly and reliably

checks PC cables using any combination of many of the most popular

computer connectors.

Two piece tester includes main unit and remote with test results at

both ends.

Small hand-held tester with one remote, allowing one-person testing

Quickly tests twisted pair cable

Checks continuity and configuration

Debug mode for fault and pair identification

Tests all common data wiring configurations

Faults detected: shorts, opens, miswires, reversals and split pairs

Accepts most centre polarised and unpolarised IDC sockets,

with any combination of 10, 14, 16, 20, 26, 34, 40, 50, 60or 64 way housings, terminated at either end of the ribbon

Conveniently checks the continuity of screened/unscreened

telephone and computer link cabling systems (up to

1000ft/0.3km). The tester accommodates RJ11/RJ45, and DEC

type plug interfaces. An immediate, simple, visual LED

indication is provided of line continuity, by depressing a

conveniently located push-button switch to initiate a test cycle.

This basic level network tester will comprehensively test

each twisted pair through RJ45 or RJ11 connectors and

comes with remote end terminator for testing link and patch

cords. An easy red and green light system will notify you of

which pairs are fully functional and which are faulty.

One button, simple testing (PASS/FAIL or fault find)

Traces wires with tone & remote lights

Quick fault analysis on coax & data cables

Cat 5, Cat 5e or Cat 6 (UTP/STP) cable testing (may not be

compatible with Cat 6 flat or oval cable, or bonded cable)

Detects opens, shorts, crossed wires and split pairs

Compact & lightweight

Easy to read LEDs with immediate pass/fail indication

Maps both cable ends instantly

Identifies continuity, opens, shorts and cross connected wires

Checks RG58, 59, 62 BNC connectors

Checks RJ11 and RJ45 connectors

Checks 9, 15 and 25 way D connectors

Checks 15 way HD connector

Checks 36 way Centronics

Checks shield continuity

9V PP3 battery included

NetTool Series II combines powerful

NetProve diagnostics, inline Gigabit

vision, digital IntelliTone technology

Continuously sequenced LED display provides immediate

diagnosis of standard wiring faults

Fully testable shield continuity

Master and remote units snap and lock together for easy

carriage and storage

Faults detected: shorts, opens, miswires, reversals and

Tests for: open, shorted, crossed, reversed, transposed, split,

non-pair wiring

cable.

Remote terminator to test links and patch cords

Test for faults such as mis-wiring, short or reversed

wires or broken connections

For use on RJ45 connectors

Adapters included for RJ11 connectors

Supplied with: 1x6V PX2SL battery

split pairs

Supplied with: 9V PP3 battery

Kit Contents

and network, IP Phone and PC configuration testing in one

palm-sized tool. Solve PC-to-network connectivity

problems faster with NetTool. See inline between the PC

and network to quickly verify connection speed, duplex,

utilization, link configuration, health information and

network resources. View services offered, name, IP address

and subnet. Problem log alerts, duplicate IPs, unanswered

DNS queries, TCP/IP connection failures and more.

Bright LEDs clearly indicate PASS, FAIL, OPEN and SHORT conditions

Includes MEMORY facility to reduce test time

LED self test and "power down" facility to conserve battery life, supplied with comprehensive

instruction manual

Accepts 4 x AAA batteries (alkaline or zinc chloride) which should be ordered separately

Stock no. Price per OM S$ S$ S$

328-7856 unit 1+ 188·50

Stock no. Price per OM S$ S$ S$

629-5226 unit 1+ 360·00 5+ 320·00 10+ 315·00

Contents

Port interface RJ11, RJ45 or DEC Position access time 1 second I/O current 5mA (max.) Power consumption 35 m W

Network Tester

Remote End Terminator

2 x RJ11 adapters

Stock no. Price per OM S$ S$ S$

301-9697 unit 1+ 790·00 5+ 710·00

Main & Remote

2 RJ45 patch cords

2 Belt clips

The tester requires a PP3 9V battery.

NetProve� diagnostics – isolate device and application

Type UTP/STP Application Tests all common data wiring configurations Short Circuit Yes Coax Yes Open Circuit Yes STP Yes Split Pair Yes UTP Yes

Instructions manual

connectivity issues in seconds

Inline Gigabit vision - quickly troubleshoot network problems with powerful inline vision into 10/

100/Gig traffic between switches, PCs, IP phones and other devices

PoE Measurements - verify readiness of PoE systems and troubleshoot PoE device problems

Spot available network resources – See MAC and IP addresses, subnet and services offered by

active servers, routers and printers

IntelliTone digital signaling - quickly and safely locate cables on active network

Quickly solve PC-to-network connectivity problems

Verify network drops; link connectivity, speed, duplex settings, finds faults and cable length

Identify PC network configuration devices used and problems

Identify available network resources and services offered

Ping network devices using IP or DHCP

Download and print reports

Short Circuit Yes UTP Yes Open Circuit Yes STP Yes Miswire Yes Coax No Split Pair Yes

Stock no. Price per OM S$ S$ S$

233-8919 unit 1+ 295·00 3+ 275·00

Stock no. Price per OM S$ S$ S$

387-928 1 kit 1+ 230·00 6+ 215·00

Note: Does not include 9V battery (required).

Description Stock no. Price per OM S$ S$ S$

NetTool Series II Pro 134-415a unit 1+ 5130·00

NetTool Series II VOIP 134-409a unit 1+ 6163·00

Stock no. Price per OM S$ S$ S$

215-6391 unit 1+ 225·00 3+ 210·00

Type Cable Tester Miswire Yes Short Circuit Yes Application Pair testing of RJ11/RJ45 connections Open Circuit Yes Coax No

Stock no. Price per OM S$ S$ S$

557-414 unit 1+ 76·50 3+ 71·00

2276

www.nguyenxuong.com

Page 42: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Fibre Optic Test Equipment

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

New products available online every week

Visifault

Visual Fault Finder

FibreMASTER�

SIGNALTEK� - FO

Fibre Inspector PRO�

MicroMapper� WiremapChecker

VDV Pro Cable Tester

IENet Pro Tester

Quickly and easily verify the integrity of an Ethernet twisted-pair

The laser-powered Visifault locates fibres, verifies continuity

and polarity, and helps find breaks in cables, connectors and

Dirt, dust and other contaminants are the enemies of high-

speed data transmission over optical fiber. Today’s network

Easy-to-use cable tester for 2 pair and 4 pair industrial ethernet cabling. Shielded

2 pair, M12 and RJ45 ports ensure compatibility with most Industrial Ethernet

The VFF5 visual Fault Finder is a light source used to locate breaks

and bad connections in fibre optic cables. It is ideal to verify

continuity, test and find breaks in LAN’s, fibre data links and

loops.

Cable testing and verification device that quickly tests all wiring requirements in

residential and commercial environments. Dockable remote with RJ11/RJ12, RJ45

and coax interfaces, stores securely in base of main unit making it easily available

and ready for fast cable testing.

Offers capabilities such as Gigabit Ethernet Qualification,

test storage and reporting, and active link testing and adds

the powerful capability of fiber optic Qualification.

Voice - tests 3 pair USOC and 6-position RJ11/RJ12 jacks

Data - tests shielded and unshielded cable to T568A/B standard

Video - tests coax cable for opens, shorts and length with F-connector interface

Blinks network link LED for visual cable tracing

Multi-tone support for cable tracing and fault isolation

cabling installation with MicroMapper�, a compact, handheld cable tester designed

for network professionals. One button test looks for opens, shorts, crossed, reversed

and split pairs. Separate remote unit for easy, one-person testing of installed cabling

or patch cords is included.

Finds breaks, faulty splices and crimps, poor components or

connections

Slim, pocket sized and battery powered

Can be used for both single-mode and multimode cable with a

4km range

Continuous (CW) or Modulated (MOD; 1Hz Pulse) modes

Accepts ST, SC and FC connectors

Requires 2 x AA batteries (stock no. 591-225)

splices.

cabling.

A fibre optic power meter and light source.

applications require more bandwidth, making loss budgets tighter than ever. It is

critical that all optical connections are clean and free of contaminants to ensure

application success. The Fluke Networks FiberInspector Pro� video microscope

puts the solution to contaminated end-faces right before your eyes. This portable

video microscope works ten times faster than traditional scopes.

Wave Lengths 650 ±10 nm

Bright red visible laser light source

Accelerates end-to-end fibre continuity checks

Speeds fibre tracing and identification

Simplifies fibre polarity verification

Aids in location of fibre faults including tight bends, breaks and bad

connectors

Features continuous and flashing modes

Rugged case helps protect against accidental damage caused by

impact or vibration

Over 80 hours of battery life with 2 AA batteries

Handy lanyard attachment and carrying case

Features - Power Meter

Tests twisted-pair cables automatically for continuity and all major miswires

Speeds troubleshooting with easy-to-read pair-based LED fault indicators

Identifies hidden cables clearly with powerful inductive tone generator

Enables one-person testing of installed cables with separate remote unit

Tests twisted-pair cables for opens, shorts, crossed pairs, split pairs or any

miswires.

Description Stock no. Price

per

OM S$ S$ S$

VDV Pro 1 remote 702-3974 unit 1+ 410·00

VDV Pro 8 remotes 702-3978 unit 1+ 600·00

VDV Pro 1 remote and probe 702-3984 unit 1+ 440·00

Dual-magnification probe allows quick changes between 250x and 400x

Large 3.5" (9cm) display provides crisp, clear images of microscopic debris and

end-face damage

Troubleshooting is 10 times faster than with traditional scopes

Various probe adapter tips allow for inspection through many different

connector port types

Rugged carrying case and protective boot prevent damage

Simple selection between voice, 2 and 4 pair data and coax testing functions

Tests for opens, shorts, miswires, reversals, split pair and length

Indicates correct wiremap to T568A/B standards for shielded and unshielded

Identifies presence of voltage on cables

Tone generator supports four different tones making fault isolation easier

Integrated RJ45 (UTP/STP) and shielded M12 interfaces on top of unit

Detachable remote with RJ45 and shielded M12 coax interfaces

Can support additional remotes making it efficient for one person testing

Blinks network link LED for visual cable tracing

Numerical indication for UTP "No Shield" and STP "Shield"

Traditional power meter/light source kits only measure the attenuation of fiber

optic links. As Gigabit Ethernet is becoming the standard for backbone and zone

fiber optic cabling, attenuation tests alone may not be enough to guarantee

error-free performance. SIGNALTEK-FO’s Bit Error Rate testing, adds assurance

that fiber optic links can actually support high-speed data in accordance with

IEEE 802.3ab standards.

Multimode and single mode capability

Measure cable attenuation with a dynamic range of up to 20dB

Guarantee link operation at 1Gbps within IEEE error tolerances

Supplied with: FT650 Fiber Probe, FT630 Fiber Display, AC adapter/battery

charger, probe adapter tips (ST, SC, FC and universal 2.5mm patch cord tip) and

hard carrying case

Description Stock no. Price per OM S$ S$ S$

IENet Pro with 1 Remote 702-3987 unit 1+ 630·00

IENet Pro with 8 Remote 702-3980 unit 1+ 880·00

Wave Lengths 650 nm

Stock no. Price per OM S$ S$ S$

324-9416 unit 1+ 910·00

Stock no. Price per OM S$ S$ S$

513-6485 unit 1+ 230·00

850, 1300/1310, 1490 and 1550 wavelength measurement

FT630 Display

Display type 3.5 in (9 cm) TFT, active matrix

Display resolution 320 x 240 pixels

Video output NTSC

Power source Lithium Ion or AC power

Battery life 2 hours continuous use

Size and Weight 100 x 53 x 220 mm, 400 g

FT650 Fibre Probe

Magnification Low: 250 x

High: 400 x

Camera type 0.33 in (8.38 mm) CCD with adjustable focus

Light Source LED

Lighting technique Coaxial

Size and Weight 45.7 x 43.2 x 140 mm, 180 g

Stock no. Price per OM S$ S$ S$

540-8308 unit 1+ 540·00

capability

Power measurement in dBm and mW, loss display in dB

Auto Power Off

Includes universal adapter

Operates on standard 3xAAA batteries

Kit Contents

Features - Light Source

1 SIGNALTEK fiber ready near-end and 1 remote-end handset

Carrying case

Copper cable accessory kit with interfaces to RJ45, RJ11, Coax F-Type

cables, and alligator clips

Fiber optic cable accessory kit: 2 duplex LC-SC 50/125μm (2m/7ft) cables, 2

duplex LC-SC 62.5/125μm (2m/7ft) cables, 1 duplex SC-SC adapter.

8 AA alkaline batteries

2 AC power adapters with international plugs

USB interface cable

1 CD-ROM User Manual

1 Training DVD

Stock no. Price per OM S$ S$ S$

543-891 unit 1+ 6243·00

850 nm light source

Includes ST, SC and FC adapters

Power LED – lights green when light source is active

Docks in the bottom of the power meter for easy storage

Operates on standard 3xAAA batteries

Low battery indication

Wave Lengths 850 nmCable Type Data, Coax, Fibre Optic

Operating Range (dB) -60 → +3 Cable Type Single Mode and Multimode Wave Lengths 850, 1300/1310, 1490, 1550 nm

Stock no. Price per OM S$ S$ S$

563-980a unit 1+ 3551·00

Stock no. Price per OM S$ S$ S$

563-986a unit 1+ 1020·00

2277

www.nguyenxuong.com

Page 43: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Wi-Fi Test Equipment

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple a New product to range

FTK1000/2000 SimpliFiber ProBasic Verification Kit

FTK1300 SimpliFiber ProVerification Kit with FT120

FTK1350 SimpliFiber ProVerification Kit with FT500

FTK1450 SimpliFiber ProComplete Verification Kit

SimpliFiber Pro Cord Sets

AirCheck� Wi-Fi Tester

SimpliFiber Pro Power Meter

SimpliFiber Pro SinglemodeSource

Handheld wireless tester for 802.11a/b/g/n supported networks.

Integrates all Wi-Fi technologies plus interference detection,

Full-featured verification kit with FibreInspector Mini

Optical power meter with the ability to save a reference power

level, allowing direct display of fibre loss.

Starter kits for contractors and network technicians who install

Provides optical power at 1310nm and 1550nm. The source is

Full-featured verification kit with FibreViewer

and maintain fibre links. Available in singlemode or multimode

configurations, quickly verify optical loss and power levels at 850

and 1300nm or 1310 and 1550nm. Add additional sources,

microscopes, and VFL options as needed.

Kit Contents

Fibre optic test reference cord sets

Calibrated for accuracy at 6 different wavelengths (850, 1300, 1310, 1490, 1550,

1625)

Intuitive four button panel

Large LCD screen

USB serial port

channel scanning and connectivity tests. Troubleshoots the most common

Wi-Fi pain points, including;

used with SimpliFiber Pro optical power meter for testing singlemode fibre optic

cable.

Kit Contents

Complete fibre verification kit with

FibreInspector Mini

Kit Contents

Description Stock no. Price per OM S$ S$ S$

62.5 uM SC/ST cord set 1m 661-9063a unit 1+ 176·00

Supplied with: SC adapter and carrying pouch.

Dual 1310/1500 FP laser emitter

Fixed SC optical connector

Kit Contents

Coverage problems

Overloaded networks or channels

Interference

Connectivity problems

Failed access points

Rogue access points

Security settings

Client problems

SimpliFiber Pro optical power meter

850/1300nm source (SC port)

FindFibre Remote ID source

FT120 FibreViewer optical microscope

VisiFault VFL

LC and ST adapters

Carrying case

SimpliFiber Pro optical power meter

850/1300nm source (SC port)

FindFibre Remote ID source

FT500 FibreInspector Mini video microscope

VisiFault VFL

LC and ST adapters

Carrying case

Supplied with: AirCheck tester, USB cable, soft case, Getting started

guide, AirCheck Manager software CD and user manual.

SimpliFiber Pro optical power meter

Supplied with: 2xAA batteries and instruction sheet.

Resolution (dB) 0.01 Wave Lengths 850, 1300, 1310, 1490, 1550, 1625

SimpliFiber Pro optical power meter

Source

SC power-meter adapter

Carrying case

Wave Lengths 850, 1300 nmCable Type Multimode

Wave Lengths 850, 1300 nmCable Type Multimode

Cable Type Stock no. Price per OM S$ S$ S$

Multimode 661-9045 unit 1+ 5540·00

Manu.

Part No.

Wave

Lengths

(nm)

Cable Type Stock no. Price

per

OM S$ S$ S$

FTK1000 850, 1300 Multimode 661-9048 unit 1+ 4140·00

FTK2000 1310, 1550 Singlemode 661-9041 unit 1+ 4930·00

Stock no. Price per OM S$ S$ S$

702-6850 unit 1+ 4590·00

Stock no. Price per OM S$ S$ S$

661-9054 unit 1+ 10800·00

850/1300nm source (SC port)

1310/1500nm source (SC port)

2 x FindFibre Remote ID source

FT500 FibreInspector Mini video microscope

VisiFault VFL

LC and ST adapters

NFC-KIT-BOX cleaning equipment

Carrying case

Wave Lengths 1310, 1500 nmCable Type Singlemode

Stock no. Price per OM S$ S$ S$

661-9023 unit 1+ 1630·00

Accessories

Wave Lengths 850, 1300, 1310, 1500 nmCable Type Multimode and Singlemode

Accessories

Accessories

Accessories

Stock no. Price per OM S$ S$ S$

661-9032 unit 1+ 2990·00

Stock no. Price per OM S$ S$ S$

661-9057a unit 1+ 11121·00

Description Stock no. Price per OM S$ S$ S$

FT-120 Viewer 200x 389-3423 unit 1+ 880·00

FT-140 Viewer 400x 389-3439 unit 1+ 860·00

Description Stock no. Price per OM S$ S$ S$

FT-120 Viewer 200x 389-3423 unit 1+ 880·00

FT-140 Viewer 400x 389-3439 unit 1+ 860·00

Description Stock no. Price per OM S$ S$ S$

FT-120 Viewer 200x 389-3423 unit 1+ 880·00

FT-140 Viewer 400x 389-3439 unit 1+ 860·00

Description Stock no. Price per OM S$ S$ S$

Antenna 702-6863 unit 1+ 445·00

Li-On Repl. Battery 702-6866 unit 1+ 560·00

Auto Charger 702-6860 unit 1+ 84·50

AC Charger 702-6879 unit 1+ 197·00

2278

www.nguyenxuong.com

Page 44: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Line Monitors

Test Telephones

Breakout Boxes

Line Monitors

Network, Cable & Electrical TestingORDERLINE65 6865 3433

93

Many more leading brands from over 2,500 suppliers available online

Mini RS-232 Monitor

www.rssingapore.com

Oscar 250

All the telephones in this range have a high impedance passive monitor, last number redial, tone-pulse

dialling and time-break recall.

Dual Standard – DSTS 2 with DSP

www.rssingapore.com

Comtest 100C

Breakout boxes designed for rapid

checking and trouble shooting of

computer interfaces especially EIA

RS-232C (V24). The LEDs are

illuminated when signals are

present and the user may break

the signal lines by means of the

front panel dip switches and send

these signals to other lines via the

jumper wires supplied. This is

typically the method used when

pins 2 and 3 need to be cross-

wired for null modem

operation.,This break-out box

displays signals that conform to

Line monitors designed for

rapid checking and trouble

shooting of computer

interfaces especially EIA

RS-232C (V24)

Conforms to RS-232 and

discriminates against out of

tolerance signals

The LEDs on the front panels

of the testers are generally on

the signal originating side of

the unit, allowing the signal to

be broken yet remain

monitored

Separate RED and GREEN

LEDs ensure unambiguous monitoring

RS-232 and discriminates against out of tolerance signals.,The LEDs on the front panels of the testers

are generally on the signal originating side of the unit, allowing the signal to be broken yet remain

monitored. Separate RED and GREEN LEDs ensure unambiguous monitoring. RED - MARK condition

(1); GREEN - SPACE condition (0); RED and GREEN - Pulse train; Both OFF - no (or out of spec) signal.

Complete RS-232 troubleshooting tester for both DB9 and

DB25 connections

Breaks and redirects all 25 lines

102 high efficiency LED indicators

Four-state monitor on all signal lines on both DTE and

DCE

Four level bi-directional Current Loop test (4, 10, 20 and

60mA)

Ground Potential Difference test

Two DB9/25 adaptors

Oscillator and auto-ranging dB meter

suitable for any use involving the distribution

The DSTS 2 first introduced in 1988 has remained a favourite

with many telephone administrations around the world

because of its reliability and ease of use. Since its

introduction, the design has evolved in line with changes in

the technology and services deployed in the telephone

network to its present form incorporating DSP

technology.,Digital Services Protection (DSP) Test Telephones

are designed to operate safely in situations where telephone

wiring may be carrying Digital traffic, Voltage feed to remote

electronics or Hazardous voltages that result from fault

conditions or misuse of the cable

18 LEDs (9 Green, 9 Red)

Pins monitored are 2 (TXD), 3 (RXD), 4(RTS), 5 (CTS)

(DSR), 8 (CD), 20 (DTR), 11 (HS), 19(HS)

All lines are wired pin to pin

The unit has a 25-way ’D’ connector M-F line installation

500 mating cycles

30V operating voltage

30mA, 15 mΩ contact rating

Dimensions: W. 53mm D. 53mm H. 16mm.

Conversion pin-out table on rear of unit

Jumper cable set and detachable 300mm ribbon cable

Easy operation

Compact and lightweight

Battery powered (requires 1x9V PP3 battery, eg. stock no. 394-9059)

Stock no. Price per OM S$ S$ S$

202-537 unit 1+ 49·30 3+ 45·80

Digital circuit safety

Excessive voltage alarm

Automatic lock-out

No Battery Required

Tone/ pulse

Last Number Redial

High Impedance Monitor at normal listening levels

or broadcasting of audio level signals

Can be used for fault location and lining up of data/speech networks

Independent operation

Calibration in dBM

True r.m.s. reading

+10 to -50dB range

Provides a d.c. patch for control signals and line hold in telecom

applications

Built-in switchable 600Ω termination

Switchable tone source built-in

Stock no. Price per OM S$ S$ S$

360-1476 unit 1+ 390·00 3+ 365·00

3-Digit Receiver Send Frequency 800Kz to 1600Hz Resolution 0-01dB Output Impedance 600Ω with d.c. path Frequency Range 100Hz to 100Hz Power Supply 9V PP3 battery supplied Receiver Terminations (1) through – 17kΩ

High monitor level

High impact resistance

High chemical resistance

Easy non slip shoulder placement

Tone/Pulse operation

Redial in Tone and Pulse

Timed Break Recall (Flash)

Polarity Check

Ground Start/ Earth Calling

Full operation at 10mA

Protection against direct battery connection

Belt clip/hanging loop

Stock no. Price per OM S$ S$ S$

252-756 unit 1+ 630·00

Crocodile Clips (not included, order separately)300mm long lead terminated by 608A UK socket and 3 crocodile clips (earth lead is 430mm).

Krone LSA Plug (not included, order separately)235mm long lead terminated by 608A UK socket and a Krone LSA plug with an earth crocodile clip.

DC Parameters 50V, 200Ω Transmission Auto gain controlMax. o/p limitation 1.4V rms.4dB octaveRoll, off above 4KHz

Max Line Resistance 4KΩ Reception Acoustic shock protectedDynamic receiver

Current Range 10mA - >90mA Cordage CW1311 cordage with 431A plug Impedance (ReturnLoss)

>16dB 300-3.4KHz Safety Cord - case insulation. >50MΩ

Protected against 50V raw batteryindefinitely Lighting inductionprotection

Monitor >10K 0-8KHz Standards BS 6317, BS 6305, BS 2011 Dialling Loop disconnect, DTMF, LNR Approvals BABT

Description Stock no. Price per OM S$ S$ S$

DSTS 2 Test Telephone 801-522 unit 1+ 260·00

DSTS 2 - Crocodile Clip 341-3550 unit 1+ 37·70

DSTS2 - Krone LSA Plug 341-3566 unit 1+ 68·50

2279

www.nguyenxuong.com

Page 45: Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230

Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com

93

OM = Order Multiple

Fluke TS42DLX

www.rssingapore.com 65 6865 3433

Fluke TS25DData lockout and data lockout override

DSL/POTS filtering technology allows user to safely draw

The TS42 test set combines rugged DropSafe� and best-in-

class DataSafe� protection with waterproof durability, and

dial tone from a pair that is carrying voice and ADSL without

downing the ADSL service

Built-in analog tone generator for tracing and identifying

wires with a probe

DTMF digit-grabbing capability

Talk battery to supply power to non-powered (dry) pairs to

carry voice conversation

Row/column tones for single tone dialing

High voltage Lockout/Low voltage Lockout

Continual data detection in monitor mode

Amplified speaker for hands-free monitoring

Programmable phonebook stored in non-volatile memory

Speed dial (10 memories, 23 digits each)

Selectable flash and pause duration

Battery level indicator

provides powerful and versatile testing capabilities.

Superior high-impedance monitoring protects data lines

2-way hands-free speakerphone capability

Passive monitor

Over-voltage & current protection

Rugged, ergonomically designed waterproof case design for severe

weather conditions, exceeds US Mil Spec MIL-STD-810E

DropSafe� 20ft onto concrete

Top or bottom mountable, with extra large steel locking belt clip

Line-cord strain relief

Mute & polarity indication

Tone & pulse dialing

Last number redial & Speed dialing

PBX pause button

Audible ringer & Amplified speaker

Volume control levels

Hearing-aid compatible

Line and battery powered, with low battery warning

Note: This product has been safety certified for indoor use only.

Standards: Conforms to relevant European Union directives.

Electrical Current Range (Off-Hook) 10 mA to100 mA

Tone Level –3 dBm combined(typical)

DC Resistance Off-Hook 150 Ω nominal High versus Low Tone difference 2dB ± 2 dB

On-Hook >3 MΩ Memory Capacity 10 speed dial plus one last numberredial memory

AC Impedance 600 Ω nominal; 300 Hz to 3400 Hz Digit Capacity 23 digits per memory On-Hook >120 kΩ; 300 Hz to 3400 Hz Pause Duration User programmable, default 4

seconds Rotary Dial (pulse)output

Pulsing Rate 10 pps ±1 pps Hook Flash Duration User programmable, default 600 ms Break/Make Ratio 60 / 40 Automatic Speaker

Shut Off Duration User programmable, default 2minutes

Inter-digit >300 ms Battery 9V alkaline or lithium battery Interval Resistance during Break>100 kΩ

Size and Weight 254 x 96 x 107 mm, 680 g

DTMF (tone) output Tone Frequency Error ±1.5 %maximum

Electrical Return Loss >14 dB (ref 600 Ω) Tone Level –1 dBm combined (typical) DC Resistance Off-Hook 150 Ω nominal High versus Low Tone difference 2 dB ± 2

dB On-Hook >1 MΩ Memory

Capacity 10 speed-dial plus one last number redialmemory

AC Impedance Off-Hook 600 Ω nominal; 300 Hz to 3400 Hz Digit Capacity 23 digits per memory On-Hook >120 kΩ; 300 Hz to 3400 Hz Pause Duration User programmable, default 4 seconds

Rotary DialOutput

Pulsing Rate 10 pps ±1 pps Hook FlashDuration

User programmable, default 600 ms

Break/Make Ratio 60 / 40 AutomaticSpeaker ShutOff Duration

User programmable, default 5 minutes

Interdigit >300 ms Battery 9V alkaline or lithium battery Interval Resistance During Break >100 kΩ Size and Weight 200 x 68 x 40 mm, 284 g

DTMF Output Tone Frequency Error ±1.5 % maximum

Stock no. Price per OM S$ S$ S$

543-908 unit 1+ 550·00

Stock no. Price per OM S$ S$ S$

543-897 unit 1+ 465·00

2280