108
Nortel Ethernet Routing Switch 8600 Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis NN46205-303 (316314-F Rev 03) .

Nortel 8600 instalación

Embed Size (px)

DESCRIPTION

instalación nortel avaya

Citation preview

  • Nortel Ethernet Routing Switch 8600

    Installing and Maintaining theEthernet Routing Switch 8000Series Chassis

    NN46205-303 (316314-F Rev 03).

  • Document status: StandardDocument version: 01.02Document date: 10 January 2008

    Copyright 2008, Nortel NetworksAll Rights Reserved.

    Sourced in Canada and the United States of America

    LEGAL NOTICEWhile the information in this document is believed to be accurate and reliable, except as otherwise expressly agreedto in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANYKIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subjectto change without notice.

  • 3ContentsNew in this release 7Other changes 7

    Air filter 7Bezel modifications 7Document changes 7Document corrections 7Part numbers 7

    Introduction 9Regulatory information 10

    Chassis installation fundamentals 178010co chassis 178010 chassis 198006 chassis 218003 chassis 23Power supplies 24Fan trays 25Site requirements 26

    8010, 8006, and 8003 chassis 268010co chassis 27

    Hardware requirements 288010, 8006, and 8003 chassis 288010co chassis 32

    Successful installation verification 34

    8010, 8006, and 8003 chassis installation 37Positioning the chassis on a flat surface 37Mounting the chassis in an equipment rack 38Installing the cable management brackets 44

    8010co chassis installation 49Mounting the chassis in a two-post rack 49Mounting the chassis in a Hendry rack 53Installing the cable management brackets 57Installing 8004DC power supplies with the BIP 59Grounding the chassis 59

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 4 Contents

    Switch operations 67Powering on DC power supplies 67Powering on AC power supplies 69Resetting the switch 70Installing removable flash memory cards 70Removing removable flash memory cards 72Protecting memory card files 73

    Troubleshooting 75Navigation 75LED indications of problems 75Apparent module failure 76

    Module failure workaround 1 77Module failure workaround 2 77

    Failure to get a login prompt from the Console port 77Cable connection problems 78

    10BASE-T cables 78100BASE-T and 1000BASE-T cables 79GBIC cables 79

    Common procedures 81Reducing the chassis weight 81

    Part numbers 83Technical specifications 85Chassis weight 85Rack-mount 86Model 8003AC power supply 86Model 8004AC power supply 87Model 8005AC power supply 87Model 8004DC power supply 88Model 8005DC power supply 89Component input power 90Input power consumption example: 8010 chassis 90

    8004AC power supply example 918004DC power supply example 92

    Input power consumption example: 8006 chassis 928005AC power supply example 938005DC power supply example 93

    8010co chassis 94Physical specifications 94Network Equipment Building Standard 94Environmental specifications 95Maximum airflow 95

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Contents 5

    International regulatory requirements 958010 chassis 96

    Physical specifications 96Environmental specifications 97International regulatory requirements 97

    8006 chassis 99Physical specifications 99Environmental specifications 99International regulatory requirements 100

    8003 chassis 101Physical specifications 101Environmental specifications 102International regulatory requirements 102

    Index 104

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 6 Contents

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 7New in this releaseThe following sections detail whats new in Installing and Maintaining theEthernet Routing Switch 8600 Chassis (NN45205-303; 316314-F) forRelease 4.1:

    Other changesFor information about changes that are not feature-related, see the followingsections: "Air filter" (page 7) "Bezel modifications" (page 7) "Document changes" (page 7) "Document corrections" (page 7) "Part numbers" (page 7)

    Air filterInformation about the air filter in the 8010co chassis is removed. For moreinformation about installing an air filter, see Replacing an Air Filter in the8010co Chassis (313592-D).

    Bezel modificationsThe Ethernet Routing Switch 8600 chassis bezel is modified. All figures andpart lists are updated with the new bezel information.

    Document changesThis document is reformatted to comply with Nortel CustomerDocumentation Standards.

    Document corrections8692 SF/CPU and 8630GBR module power information is corrected, see"Technical specifications" (page 85).

    Part numbersTable 6 "Accessories shipped with the 8010, 8006, and 8003 chassis" (page28) is updated with part numbers.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 8 New in this release

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 9IntroductionThe Nortel Ethernet Routing Switch 8600 chassis provides the physicalframework for the Nortel Ethernet Routing Switch 8600 modules.

    This document provides the instructions to install the Nortel EthernetRouting Switch 8600 chassis in an equipment rack. This document alsodescribes some of the routine tasks to operate the Nortel Ethernet RoutingSwitch 8600 and includes technical specifications for the chassis andmodules.

    Prerequisites Before you install the Nortel Ethernet Routing Switch 8600 chassis,

    ensure that you install all network wiring on the premises by usingstandard cable-system practices.

    Navigation "Chassis installation fundamentals" (page 17) "8010, 8006, and 8003 chassis installation" (page 37) "8010co chassis installation" (page 49) "Switch operations" (page 67) "Troubleshooting" (page 75) "Common procedures" (page 81) "Part numbers" (page 83) "Technical specifications" (page 85)

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 10 Introduction

    Regulatory informationInternational regulatory statements of conformity

    This is to certify that the Nortel Networks 8000 Series chassis andcomponents installed within the chassis were evaluated to the internationalregulatory standards for electromagnetic compliance (EMC) and safety andwere found to have met the requirements for the following internationalstandards: EMCElectromagnetic EmissionsCISPR 22, Class A EMCElectromagnetic ImmunityCISPR 24 Electrical SafetyIEC 60950, with CB member national deviations

    Further, the equipment has been certified as compliant with the nationalstandards as detailed in the following sections.

    National electromagnetic compliance (EMC) statements of complianceFCC statement (USA only)This equipment has been tested and found to comply with the limits for aClass A digital device, pursuant to Part 15 of the Federal CommunicationsCommission (FCC) rules. These limits are designed to provide reasonableprotection against harmful interference when the equipment is operatedin a commercial environment. This equipment generates, uses, and canradiate radio frequency energy. If it is not installed and used in accordancewith the instruction manual, it may cause harmful interference to radiocommunications. Operation of this equipment in a residential area is likelyto cause harmful interference, in which case users will be required to takewhatever measures may be necessary to correct the interference at theirown expense.

    ICES statement (Canada only)Canadian Department of Communications Radio InterferenceRegulations This digital apparatus (8000 Series chassis and installedcomponents) does not exceed the Class A limits for radio-noise emissionsfrom digital apparatus as set out in the Radio Interference Regulations ofthe Canadian Department of Communications.

    Rglement sur le brouillage radiolectrique du ministre desCommunications Cet appareil numrique (8000 Series chassis) respecteles limites de bruits radiolectriques visant les appareils numriques declasse A prescrites dans le Rglement sur le brouillage radiolectrique duministre des Communications du Canada.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Regulatory information 11

    CE marking statement (Europe only)EN 55 022 statements This is to certify that the Nortel Networks 8000Series chassis and components installed within the chassis are shieldedagainst the generation of radio interference in accordance with theapplication of Council Directive 89/336/EEC. Conformity is declared by theapplication of EN 55 022 Class A (CISPR 22).

    ATTENTIONThis is a Class A product. In a domestic environment, this product may causeradio interference, in which case, the user may be required to take appropriatemeasures.

    Achtung:Dieses ist ein Gert der Funkstrgrenzwertklasse A. In Wohnbereichen knnenbei Betrieb dieses Gertes Rundfunkstrungen auftreten, in welchen Fllen derBenutzer fr entsprechende Gegenmanahmen verantwortlich ist.

    Attention:Ceci est un produit de Classe A. Dans un environnement domestique, ce produitrisque de crer des interfrences radiolectriques, il appartiendra alors lutilisateur de prendre les mesures spcifiques appropries.

    EN 55 024 statement This is to certify that the Nortel Networks 8000Series chassis is shielded against the susceptibility to radio interferencein accordance with the application of Council Directive 89/336/EEC.Conformity is declared by the application of EN 55 024 (CISPR 24).

    EC Declaration of Conformity This product conforms to the provisionsof the R&TTE Directive 1999/5/EC.

    VCCI statement (Japan/Nippon only)This is a Class A product based on the standard of the Voluntary ControlCouncil for Interference (VCCI) for information technology equipment. If thisequipment is used in a domestic environment, radio disturbance may arise.When such trouble occurs, the user may be required to take correctiveactions.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 12 Introduction

    BSMI statement for 8010, 8006 and 8003 chassis (Taiwan only)This is a Class A product based on the standard of the Bureau of Standards,Metrology and Inspection (BSMI) CNS 13438, Class A.

    MIC notice for 8010, 8006, 8003 chassis (Republic of Korea only)This device has been approved for use in Business applications only perthe Class A requirements of the Republic of Korea Ministry of Informationand Communications (MIC). This device may not be sold for use in anon-business application.

    National safety statements of complianceCE marking statement (Europe only)EN 60 950 statement This is to certify that the Nortel Networks 8000Series chassis and components installed within the chassis are incompliance with the requirements of EN 60 950 in accordance with the LowVoltage Directive. Additional national differences for all European Unioncountries have been evaluated for compliance. Some components installedwithin the 8000 Series chassis may use a nickel-metal hydride (NiMH)and/or lithium-ion battery. The NiMH and lithium-ion batteries are long-lifebatteries, and it is very possible that you will never need to replace them.However, should you need to replace them, refer to the individual componentmanual for directions on replacement and disposal of the battery.

    NOM statement 8010, 8006, and 8003 chassis (Mexico only)The following information is provided on the devices described in thisdocument in compliance with the safety requirements of the Norma OficialMxicana (NOM):

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Regulatory information 13

    Exporter: Nortel Networks, Inc.4655 Great America ParkwaySanta Clara CA 95054 USA

    Importer: Nortel Networks de Mxico, S.A. de C.V.Avenida Insurgentes Sur #1605Piso 30, OficinaCol. San Jose InsurgentesDeleg-Benito JuarezMxico D.F. 03900

    Tel: 52 5 480 2100Fax: 52 5 480 2199Input: Model 8003AC:

    100-240 V AC, 50-60 Hz, 9 A maximum for each powersupplyModel 8004AC:100-240 V AC, 50 to 60 Hz, 12-6 A maximum for eachpower supplysingle supply, single supply + one redundant supply, twosupplies, or two + one redundant supply configurationModel 8005AC:100 to 120 V AC, 50 to 60 Hz, 16 A maximum for eachpower supply200 to 240 V AC, 50 to 60 Hz, 9.5 A maximum for eachpower supplysingle supply, single supply + one redundant supply, twosupplies, or two + one redundant supply configurationModel 8004DC:-48 VDC, 29 Asingle supply, single supply + one redundant supply, twosupplies, or two + one redundant supply configurationModel 8005DC:-48 VDC, 42 Asingle supply, single supply + one redundant supply, twosupplies, or two + one redundant supply configuration

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 14 Introduction

    Informacin NOM (unicamente para Mxico)La informacin siguiente se proporciona en el dispositivo o en losdispositivos descritos en este documento, en cumplimiento con losrequisitos de la Norma Oficial Mxicana (NOM):

    Exportador: Nortel Networks, Inc.4655 Great America ParkwaySanta Clara, CA 95054 USA

    Importador: Nortel Networks de Mxico, S.A. de C.V.Avenida Insurgentes Sur #1605Piso 30, OficinaCol. San Jose InsurgentesDeleg-Benito JuarezMxico D.F. 03900

    Tel: 52 5 480 2100Fax: 52 5 480 2199Embarcar a: Model 8003AC:

    100-240 VCA, 50-60 Hz, 9 A max. por fuente de poderModel 8004AC:100-240 VCA, 50 - 60 Hz, 12-6 A max. por fuente depoderuna fuente, una fuente + configuraciones de una fuenteredundante, dos fuentes o dos + configuraciones deuna fuente redundanteModel 8005AC:100 - 120 VCA, 50 -60 Hz, 16 A max. por fuente depoder200 - 240 VCA, 50 - 60 Hz, 9.5 A max. por fuente depoderuna fuente, una fuente + configuraciones de una fuenteredundante, dos fuentes o dos + configuraciones deuna fuente redundanteModel 8004DC:-48 VCD, 29 Auna fuente, una fuente + configuraciones de una fuenteredundante, dos fuentes o dos + configuraciones deuna fuente redundanteModel 8005DC:

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Regulatory information 15

    -48 VCD, 42 Auna fuente, una fuente + configuraciones de una fuenteredundante, dos fuentes o dos + configuraciones deuna fuente redundante

    Denan statement (Japan/Nippon only)

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 16 Introduction

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 17

    Chassis installation fundamentalsEach Nortel Ethernet Routing Switch 8600 chassis consists of a sheet metalenclosure, a backplane, and a power backplane. The number of bays forpower supplies and the number of fan trays depends on the chassis type.For information about the minimum software versions required to supportthe hardware, see Network Design Guidelines (313197-E).The section includes information about the following chassis types: 8010co chassis 8010 chassis 8006 chassis 8003 chassis

    Navigation "8010co chassis" (page 17) "8010 chassis" (page 19) "8006 chassis" (page 21) "8003 chassis" (page 23) "Power supplies" (page 24) "Fan trays" (page 25) "Site requirements" (page 26) "Hardware requirements" (page 28) "Successful installation verification" (page 34)

    8010co chassisAs shown in Figure 1 "8010co chassis and components" (page 19), the8010co chassis has eight slots for interface modules and two slots for the8691 Switch Fabric/Central Processor Unit (SF/CPU) or 8692 SF/CPUmodules. Slots are numbered from left to right. You can install NortelEthernet Routing Switch 8600 interface modules in slots 1 through 4 and inslots 7 through 10. Slots 5 and 6 are reserved for Nortel Ethernet Routing

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 18 Chassis installation fundamentals

    Switch 8600 modules. For information about Nortel Ethernet RoutingSwitch 8600 modules, see Installing Ethernet Routing Switch 8600 Modules(NN46205-304; 312749-K).The 8010co chassis has three bays for either alternating current (AC) ordirect current (DC) power supplies. The 8010co chassis supports thefollowing AC power supplies: 8004AC 8005AC

    The 8010co chassis supports the following DC power supplies: 8004DC 8005DC

    CAUTIONRisk of equipment damageThe 8004 and 8005 power supplies use different power ratings.Nortel recommends that you do not operate the Nortel EthernetRouting Switch 8600 chassis with a mix of power supply models(8004 and 8005).If you upgrade the Nortel Ethernet Routing Switch 8600 and use aredundant power configuration, you can hot swap the 8004 powersupply with the 8005 power supply while the Nortel EthernetRouting Switch 8600 remains in operation. Do not operate thechassis with a mix of power supply models for an extended periodof time.Upgrade the power supplies before you upgrade the modules.

    For information about power supply installation, see Installing an AC PowerSupply in an Ethernet Routing Switch 8000 Series Chassis (NN46205-306;312751-E) or Installing a DC Power Supply in an Ethernet Routing Switch8000 Series Chassis (NN46205-307; 313070-E). The 8010co chassis usestwo fan trays for cooling, see Installing a Fan Tray in an Ethernet RoutingSwitch 8000 Series Chassis (312752-E).

    Figure 1 "8010co chassis and components" (page 19) shows the location ofcustomer-replaceable components in the 8010co chassis.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 8010 chassis 19

    Figure 18010co chassis and components

    8010 chassisAs shown in Figure 2 "8010 chassis and components" (page 21), the 8010chassis has eight slots for interface modules and two slots for the 8691SF/CPU or 8692 SF/CPU modules. Slots are numbered from the top down.You can install Nortel Ethernet Routing Switch 8600 interface modules inslots 1 through 4 and in slots 7 through 10. Slots 5 and 6 are reserved forNortel Ethernet Routing Switch 8600 SF/CPU modules.For complete information about module installation, see Installing EthernetRouting Switch 8600 Modules (NN46205-304; 312749-K).The 8010 chassis uses three bays for either AC or DC power supplies. The8010 chassis supports the following AC power supplies: 8001AC (discontinued)

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 20 Chassis installation fundamentals

    8004AC 8005AC

    The 8010 chassis supports the following DC power supplies: 8002DC (discontinued) 8004DC 8005DC

    CAUTIONRisk of equipment damageNortel does not support 8001AC and 8002DC power supplies withR modules. R modules installed in the 8006, 8010, or 8010cochassis require the 8004AC, 8004DC, 8005AC, or 8005DC powersupplies.

    CAUTIONRisk of equipment damageThe 8004 and 8005 power supplies use different power ratings.Nortel recommends that you do not operate the Nortel EthernetRouting Switch 8600 chassis with a mix of power supply models(8004 and 8005).If you upgrade the Nortel Ethernet Routing Switch 8600 and use aredundant power configuration, you can hot swap the 8004 powersupply with the 8005 power supply while the Nortel EthernetRouting Switch 8600 remains in operation. Do not operate thechassis with a mix of power supply models for an extended periodof time.Upgrade the power supplies before you upgrade the modules.

    For information about power supply installation, see Installing an AC PowerSupply in an Ethernet Routing Switch 8000 Series Chassis (NN46205-306;312751-E) or Installing a DC Power Supply in an Ethernet Routing Switch8000 Series Chassis (NN46205-307; 313070-E). The 8010 chassis usestwo fan trays for cooling, see Installing a Fan Tray in an Ethernet RoutingSwitch 8000 Series Chassis (312752-E).

    Figure 2 "8010 chassis and components" (page 21) shows the location ofcustomer-replaceable components in the 8010 chassis.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 8006 chassis 21

    Figure 28010 chassis and components

    8006 chassisAs shown in Figure 3 "8006 chassis and components" (page 23), the 8006chassis provides four slots for interface modules and two slots for 8691SF/CPU or 8692 SF/CPU modules. The top four slots are for the installationof 8600 interface modules. Slots 5 and 6 are reserved for Nortel EthernetRouting Switch 8600 SF/CPU modules.For information about module installation, see Installing Ethernet RoutingSwitch 8600 Modules (NN46205-304; 312749-K).The 8006 chassis uses three bays for either AC or DC power supplies. The8006 chassis supports the following AC power supplies: 8001AC (discontinued) 8004AC 8005AC

    The 8006 chassis supports the following DC power supplies: 8002DC (discontinued) 8004DC 8005DC

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 22 Chassis installation fundamentals

    CAUTIONRisk of equipment damageNortel does not support 8001AC and 8002DC power supplies withR modules. R modules installed in the 8006, 8010, or 8010cochassis require the 8004AC, 8004DC, 8005AC, or 8005DC powersupplies.

    CAUTIONRisk of equipment damageThe 8004 and 8005 power supplies use different power ratings.Nortel recommends that you do not operate the Nortel EthernetRouting Switch 8600 chassis with a mix of power supply models(8004 and 8005).If you upgrade the Nortel Ethernet Routing Switch 8600 and use aredundant power configuration, you can hot swap the 8004 powersupply with the 8005 power supply while the Nortel EthernetRouting Switch 8600 remains in operation. Do not operate thechassis with a mix of power supply models for an extended periodof time.Upgrade the power supplies before you upgrade the modules.

    For information about power supply installation, see Installing an AC PowerSupply in an Ethernet Routing Switch 8000 Series Chassis (NN46205-306;312751-E) or Installing a DC Power Supply in an Ethernet Routing Switch8000 Series Chassis (NN46205-307; 313070-E). The 8006 chassis usestwo fan trays for cooling, see Installing a Fan Tray in an Ethernet RoutingSwitch 8000 Series Chassis (312752-E).

    Figure 3 "8006 chassis and components" (page 23) shows the location ofcustomer-replaceable components in the 8006 chassis.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 8003 chassis 23

    Figure 38006 chassis and components

    8003 chassisAs shown in Figure 4 "8003 chassis and components" (page 24), the 8003chassis provides two slots for interface modules and one slot for an 8691SF/CPU module.

    ATTENTIONThe 8003 chassis does not support the 8692 SF/CPU with 8000 Series SoftwareRelease 3.7.The 8003 chassis does not support the following R modules with SoftwareRelease 4.x:

    8630GBR 8648GTR 8683XLR 8683XZR

    Slots are numbered from the top down. Install Nortel Ethernet RoutingSwitch 8600 interface modules in slots 1 and 2. Slot 3 is reserved forthe 8690 SF/CPU or 8691 SF/CPU module. For information aboutmodule installation, see Installing Ethernet Routing Switch 8600 Modules(NN46205-304; 312749-K).

    The 8003 chassis uses two bays for 8003AC power supplies and a single8003 fan tray for cooling.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 24 Chassis installation fundamentals

    For information about power supply and fan installation, see Installing anAC Power Supply in an Ethernet Routing Switch 8000 Series Chassis(NN46205-306; 312751-E) and Installing a Fan Tray in an Ethernet RoutingSwitch 8000 Series Chassis (312752-E).

    Figure 4 "8003 chassis and components" (page 24) shows the location ofcustomer-replaceable components in the 8003 chassis.

    Figure 48003 chassis and components

    Power suppliesThe 8010 and 8006 chassis each provide three bays for power supplyinstallation. The following power supplies are available for these chassis: 8001AC (discontinued) 8004AC 8005AC 8002DC (discontinued) 8004DC 8005DC

    The 8010co chassis provides three bays for power supply installation. Thefollowing power supplies are available for these chassis: 8004AC 8005AC 8004DC 8005DC

    You require a minimum of two power supplies for the 8010co chassis. Youcan install an additional power supply for redundancy.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Fan trays 25

    CAUTIONRisk of equipment damageNortel does not support 8001AC and 8002DC power supplies withR modules. R modules installed in the 8006, 8010, or 8010cochassis require the 8004AC, 8004DC, 8005AC, or 8005DC powersupplies.

    CAUTIONRisk of equipment damageThe 8004 and 8005 power supplies use different power ratings.Nortel recommends that you do not operate the Nortel EthernetRouting Switch 8600 with a mix of power supply models (8004and 8005).If you upgrade the Nortel Ethernet Routing Switch 8600 and use aredundant power configuration, you can hot swap the 8004 powersupply with the 8005 power supply while the Nortel EthernetRouting Switch 8600 remains in operation. Do not operate thechassis with a mix of power supply models for an extended periodof time.Upgrade the power supplies before you upgrade the modules.

    The 8003 chassis provides two bays for 8003AC power supply installation.Each power supply provides 500 watts (W) of output power for the switch.Two power supplies constitute a redundant power configuration for allinstalled module configurations in the chassis.

    For power supply and system power technical specifications, see "Technicalspecifications" (page 85).

    For information about power supply installation, see Installing an AC PowerSupply in an Ethernet Routing Switch 8000 Series Chassis (NN46205-306;312751-E) or Installing a DC Power Supply in an Ethernet Routing Switch8000 Series Chassis (NN46205-307; 313070-E).

    Fan traysThe following table lists the number of fan trays for each Nortel EthernetRouting Switch 8600 chassis.

    Table 1Number of fan trays installed in each chassisChassis Fan tray8010co Two fan trayseach fan tray uses two high-capacity fans

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 26 Chassis installation fundamentals

    Chassis Fan tray8010 Two fan trayseach fan tray uses eight high-capacity fans8006 One fan tray with six high-capacity fans8003 One fan tray with three high-capacity fans

    A control or monitor circuit board in the fan tray reports temperature and thestatus of fan operation to the network management software. A green lightemitting diode (LED) indicates correct fan operation.

    For fan installation instructions, see Installing a Fan Tray in an EthernetRouting Switch 8000 Series Chassis (312752-E).

    Site requirementsEnsure that the installation site meets the space, electrical, andenvironmental requirements listed in this section. See "Technicalspecifications" (page 85) for more information.

    8010, 8006, and 8003 chassisThe following sections include the site requirements for the 8010, 8006,and 8003 chassis.

    Space requirementsThe installation site must provide sufficient free space around the chassisto ensure proper ventilation and service access.Use the following guidelines to plan front and rear access: The maintenance aisle in front of the frame requires a clearance of

    76.2 cm (30 inches). The wiring aisle at the back of the frame requires a clearance of 61 cm

    (24 inches).

    AC input electrical requirementsFor information about specifications for the power supply, see "Technicalspecifications" (page 85).

    For AC input power specifications for each of the modules, see Installingan AC Power Supply in an Ethernet Routing Switch 8000 Series Chassis(NN46205-306; 312751-E).

    DC input electrical requirements (8010 and 8006 chassis)The installation site must meet the electrical requirements for DC power asshown in Table 2 "Electrical requirements for the DC models" (page 27). Foradditional electrical requirements, see "Technical specifications" (page 85).

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Site requirements 27

    Table 2Electrical requirements for the DC modelsDC power supply Nominal input voltage Input current Input power8004DC 48 VDC 29 A 1392 W8005DC 48 VDC/ 60 VDC 42 A/34 A 1950 W

    Environmental requirementsThe installation site must meet the environmental requirements shown inTable 3 "Environmental requirements" (page 27).Table 3Environmental requirementsAltitude Humidity Temperature010 000 ft (0 to 3048m)

    5%85%, noncondensing 32F104F (0C40C),stable

    8010co chassisThe following sections include the site requirements for the 8010co chassis.

    Space requirementsThe installation site must provide sufficient free space around the 8010cochassis to ensure proper ventilation and service access.Use the following guidelines to plan front and rear access: The maintenance aisle in front of the frame requires a clearance of

    76.2 cm (30 inches). The wiring aisle at the back of the frame requires a clearance of 61 cm

    (24 inches).

    AC input electrical requirementsFor information about specifications for the power supply, see "Technicalspecifications" (page 85).

    DC input electrical requirementsIf you install a Breaker Interface Panel (BIP), the installation site must meetthe electrical requirements for DC power shown in Table 4 "DC powerrequirement for BIP" (page 27).Table 4DC power requirement for BIPNominal input voltage Maximum input current Physical 48 VDC 60 A for each DC input

    feedReinforced insulationfrom the main DC power

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 28 Chassis installation fundamentals

    If you do not install a BIP, see the system power specifications for the8004DC or 8005DC power supply in "Technical specifications" (page 85).

    Environmental requirementsThe installation site must meet the environmental requirements shown inTable 5 "Environmental requirements" (page 28).Table 5Environmental requirementsEnvironmental specificationsOperating temperature 5 to 55C (23 to 131F)Storage temperature 40 to 70C ( 40 to 158F)Operating humidity 90%Storage humidity 92.5%Operating altitude 13 123 ft at 35C and 45C

    6000 ft at 55C 200 ft at 55C

    Storage altitude 40 000 ft

    Hardware requirementsThis section includes information about the hardware shipped with the8010co, 8010, 8006, and 8003 chassis.

    8010, 8006, and 8003 chassisThe following table is a checklist of items included in the shipment container.

    Table 6Accessories shipped with the 8010, 8006, and 8003 chassisCheck Accessory Part number Usage

    Bracket kit with Two rack-mounting brackets Phillips-head screws

    Prepare the chassis forinstallation in an equipmentrack.

    Screw package Mount the chassis in anequipment rack.

    Side cable management brackets two brackets for the 8010

    chassis one bracket each for the 8006

    and 8003 chassis

    DS1411013 Manage network interfacecables.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Hardware requirements 29

    Check Accessory Part number UsageRubber footpads Keep the chassis from

    slipping when you mount it ona flat surface.

    Console cable DS1411012 Connect an optionalmanagement console tothe chassis. Each end of theconsole cable uses a DB-25and a DB-9 connector.

    Figure 5 "Items in the 8010 chassis shipping container" (page 29), Figure6 "Items in the 8006 chassis shipping container" (page 30), and Figure 7"Items in the 8003 chassis shipping container" (page 31) illustrate the itemsin the chassis shipping container.

    Figure 5Items in the 8010 chassis shipping container

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 30 Chassis installation fundamentals

    Figure 6Items in the 8006 chassis shipping container

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Hardware requirements 31

    Figure 7Items in the 8003 chassis shipping container

    Other equipmentYou need items not included in the 8010, 8006, or 8003 chassis accessorypackage. The following sections describe these items. Before you install thehardware, ensure that you have all the cables, tools, and other equipmentyou need.

    Management consoleTo configure startup options and to monitor the results of startup diagnostics,you can either attach an optional PC, laptop, video terminal (VT)-100console or equivalent, such as a PC terminal emulator, or you can attachan AT-compatible modem to allow dial-in access to startup configurationand diagnostics.

    CablesUnless you specifically order them, Nortel does not include the cablesrequired for your network configuration in the chassis accessory package. Ifyou need the proper cables, contact your network administrator.

    Mounting hardware for the 8010, 8006, 8003 chassis

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 32 Chassis installation fundamentals

    To install the 8010, 8006, or 8003 chassis in an equipment rack, you needa Phillips screwdriver and an equipment rack that meets the followingspecifications: Heavy-duty steel construction Electronic Industries Association (EIA) standard hole spacing Width of 19 in. (48.26 cm) and depth of 24 in. (60.96 cm)

    8010co chassisIn addition to the 8010co chassis, your shipping container contains severalhardware accessories. Verify that the items in the shipping container matchthose on the shipment packing list.

    Use Table 7 "8010co chassis shipping accessories" (page 32) as a checklistwhen you verify the contents of the shipping container.

    Table 78010co chassis shipping accessoriesCheck Accessory Usage

    Antistatic wrist strap Direct the discharge of static electricity fromyour body to the chassis and avoid dischargeto, and possible damage of, sensitive electroniccomponents.

    One 10-ft console serial cable Connect an optional management console.Screws and hardware: The hardware required to mount the chassis in a

    rack depends on your rack type.12 Phillips-head screws12 self-tapping hex-head screws12 clip nuts

    Mount the chassis to a rack rail.

    Mount the chassis to a Hendry rack.Use the clip nuts if necessary.The hardware required to mount the installation shelfin a rack depends on your rack type.

    4 Phillips-head screws4 hex nuts4 self-tapping hex-head

    Mount the installation shelf to a rack rail.Mount the installation shelf to a rack rail.Mount the installation shelf to a Hendry rack.

    4 pan-head screws Install the cable management bracket.Installation shelf Mount the 8010co chassis in an equipment rack.One upper cable managementbracket

    Manage network interface cables.

    Two side cable managementbrackets

    Manage network interface cables.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Hardware requirements 33

    Figure 8 "Accessories in the 8010co chassis shipping container" (page33) illustrates the accessories in the 8010co chassis shipping container.

    Figure 8Accessories in the 8010co chassis shipping container

    Other equipmentYou can require items not included in the 8010co chassis accessorypackage. The following sections describe these items. Before you installthe 8010co hardware, ensure that you obtain all the cables, tools, and otherequipment you need.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 34 Chassis installation fundamentals

    Management consoleTo configure startup options and to monitor the results of startup diagnostics,you can attach a PC, laptop, VT100 console or equivalent, such as a PCterminal emulator, or you can attach a configured AT-compatible modem toallow dial-in access to startup configuration and diagnostics.

    Hardware for mounting the chassis in an equipment rackThe hardware required to mount the 8010co chassis in an equipment rackdepends on your equipment rack type.You need a Phillips screwdriver to install the 8010co chassis in a standardrail-type equipment rack. You need a nutdriver to install the 8010co chassisin a Hendry rack.The racks must meet the following specifications: Heavy-duty steel construction Electronic Industries Association (EIA) standard hole spacing Two-post rack with a width of 19 in. (48.26 cm) and a depth of 24 in.

    (60.96 cm) Two-post rack with a width of 23 in. (58.42 cm) and a depth of 24 in.

    (60.96 cm) (Requires an EIA 19 to 23-in. adapter. Contact your rackmanufacturer to order the adapter.)

    If the rack does not use threaded rail holes, you must use the supplied clipnuts with the clip nut screws.

    CablesUnless you specifically order them, Nortel does not include the cablesrequired for your network configuration in the 8010co chassis accessorypackage. If you require the proper cables, contact your networkadministrator.

    Successful installation verificationIn a normal power-up sequence, the LEDs light as follows: After you apply power to the switch, the green LED on each power supply

    and fan tray lights, and the Online LED for each module lights amber. Each module initiates a self-test, during which the port and module

    LEDs display various patterns to indicate the progress of the self-test. Upon successful completion of the self-test (within 2 or 3 minutes after

    you apply power for a fully-loaded chassis), the module Online LEDtransitions from amber to green.

    After 1 minute of operation, the fan tray Pass LED lights steady green.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Successful installation verification 35

    If the LEDs on the modules light in this sequence, your installation issuccessful. Contact your network administrator to verify that the NortelEthernet Routing Switch 8600 is now connected to the network.

    If the LEDs do not light in this sequence, contact your local Nortel TechnicalSolutions Center.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 36 Chassis installation fundamentals

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 37

    8010, 8006, and 8003 chassisinstallation

    This section describes how to install the 8010, 8006, and 8003 chassis.

    Navigation "Reducing the chassis weight" (page 81) "Positioning the chassis on a flat surface" (page 37) "Mounting the chassis in an equipment rack" (page 38) "Installing the cable management brackets" (page 44)

    Prerequisites to chassis installation Inspect all items for shipping damage. If you detect damage, do not

    install the chassis. Call the Nortel Technical Solutions Center in yourarea.

    Verify that the items in the shipping container match those on theshipment packing list. Use Table 6 "Accessories shipped with the 8010,8006, and 8003 chassis" (page 28) as a checklist when you verify thecontents of the shipping container.

    Verify that you have all other required hardware.

    Positioning the chassis on a flat surfaceAs long as you provide adequate space around the unit for access to cableconnectors, you can mount the chassis onto an appropriate flat, levelsurface that can safely support the weight of the chassis, the components,and the attached cables.

    Procedure steps

    Step Action

    1 Place the switch on the flat surface and check for proper ventilation.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 38 8010, 8006, and 8003 chassis installation

    Allow at least 2 in. (5.1 cm) on each side for proper ventilation and 5in. (12.7 cm) at the front for power cord clearance.

    2 Attach rubber feet to each marked location on the bottom of thechassis.The rubber feet are optional but Nortel recommends that you usethem to help keep the unit from moving.

    End

    Mounting the chassis in an equipment rackMount the chassis in a standard 19 in. equipment rack. If you mountthe chassis in a 23 in. equipment rack, see the rack adapter installationinstructions provided by the rack manufacturer.

    Prerequisites You need the following items:

    Standard 19-in. (48.2 cm) equipment rack 10 screws and washers (extra screws ship with the 8010 chassis) Phillips screwdriver

    Procedure steps

    Step Action

    1 Hold each rack-mounting bracket against one side of the chassis.Ensure the attachment holes in the bracket match the holes in thechassis.Each bracket fits only one side of the chassis. The brackets arelabeled R (right) and L (left). If the mounting holes do not line upbetween a bracket and the chassis, try that bracket on the otherside of the chassis.For more information about positioning the rack-mounting brackets,see "Positioning the rack-mounting brackets: 8010 chassis" (page39), "Positioning the rack-mounting brackets: 8006 chassis" (page39), and "Positioning the rack-mounting brackets: 8003 chassis"(page 39).

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Mounting the chassis in an equipment rack 39

    Positioning the rack-mounting brackets: 8010 chassis

    Positioning the rack-mounting brackets: 8006 chassis

    Positioning the rack-mounting brackets: 8003 chassis

    2 Insert and tighten the supplied Phillips-head screws to fasten eachbracket to the chassis.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 40 8010, 8006, and 8003 chassis installation

    For more information about attaching the rack-mounting brackets,see "Attaching the rack-mounting brackets to the 8010 chassis"(page 40), "Attaching the rack-mounting brackets to the 8006chassis" (page 40), and "Attaching the rack-mounting brackets to the8003 chassis" (page 41).Attaching the rack-mounting brackets to the 8010 chassis

    Attaching the rack-mounting brackets to the 8006 chassis

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Mounting the chassis in an equipment rack 41

    Attaching the rack-mounting brackets to the 8003 chassis

    3 Measure the appropriate number of rack units of free vertical spaceinside the rack and mark the spot.For more information about the number of rack units to allocate foreach chassis, see "Procedure job aid" (page 44).

    4 Hold the chassis in position and align the flanged end of eachmounting rail with the two holes on each side of the vertical racksupport.Complete this step with two people. Ensure that the hole pairs oneither side of the vertical support match horizontally. For moreinformation about aligning the rack-mounting brackets, see "Aligningthe rack-mounting brackets with the equipment rack: 8010 chassis"(page 41), "Aligning the rack-mounting brackets with the equipmentrack: 8006 chassis" (page 42), and "Aligning the rack-mountingbrackets with the equipment rack: 8003 chassis" (page 42).Aligning the rack-mounting brackets with the equipment rack: 8010chassis

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 42 8010, 8006, and 8003 chassis installation

    Aligning the rack-mounting brackets with the equipment rack: 8006chassis

    Aligning the rack-mounting brackets with the equipment rack: 8003chassis

    5 Insert and tighten the rack-mounting screws with a Phillipsscrewdriver.For more information about rack installation, see "Installing the 8010chassis in an equipment rack" (page 43), "Installing the 8006 chassisin an equipment rack" (page 43), and "Installing the 8003 chassis inan equipment rack" (page 43).

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Mounting the chassis in an equipment rack 43

    Installing the 8010 chassis in an equipment rack

    Installing the 8006 chassis in an equipment rack

    Installing the 8003 chassis in an equipment rack

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 44 8010, 8006, and 8003 chassis installation

    End

    Procedure job aidTable 8 "Number of rack units to allocate for chassis" (page 44) lists thenumber of rack units to allocate for each chassis.

    Table 8Number of rack units to allocate for chassis

    Chassis Rack units Inches8010 13.2 23.18006 9.7 16.98003 6.0 10.5

    Installing the cable management bracketsInstall the cable management brackets to keep cable clusters fastened andout of the way but still accessible for maintenance.

    Procedure steps

    Step Action

    1 Loosen, but do not remove, the rack-mounting screws needed toinstall one cable management brackets.For more information about loosening the rack-mounting screws,see "Loosening the rack-mounting screws: 8010 chassis" (page 44),"Loosening the rack-mounting screws: 8006 chassis" (page 45), and"Loosening the rack-mounting screws: 8003 chassis" (page 45).Loosening the rack-mounting screws: 8010 chassis

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Installing the cable management brackets 45

    Loosening the rack-mounting screws: 8006 chassis

    Loosening the rack-mounting screws: 8003 chassis

    2 Slide the bracket onto the loosened screws.For more information about sliding the bracket onto the screws,see "Sliding the bracket onto the screws: 8010 and 8006 chassis"(page 45) and "Sliding the bracket onto the screws: 8003 chassis"(page 46).Sliding the bracket onto the screws: 8010 and 8006 chassis

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 46 8010, 8006, and 8003 chassis installation

    Sliding the bracket onto the screws: 8003 chassis

    3 Tighten the screws to secure the bracket to the chassis.For more information about tightening the screws, see "Securingthe bracket to the chassis: 8010 chassis" (page 46), "Securing thebracket to the chassis: 8006 chassis" (page 47), and "Securing thebracket to the chassis: 8003 chassis" (page 47).Securing the bracket to the chassis: 8010 chassis

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Installing the cable management brackets 47

    Securing the bracket to the chassis: 8006 chassis

    Securing the bracket to the chassis: 8003 chassis

    End

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 48 8010, 8006, and 8003 chassis installation

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 49

    8010co chassis installationThis section describes how to install the 8010co chassis.

    Navigation "Reducing the chassis weight" (page 81) "Mounting the chassis in a two-post rack" (page 49) "Mounting the chassis in a Hendry rack" (page 53) "Installing the cable management brackets" (page 44) "Installing 8004DC power supplies with the BIP" (page 59) "Grounding the chassis" (page 59)

    Prerequisites to chassis installation Before you begin the installation, verify that

    Inspect all items for shipping damage. If you detect damage, do notinstall the chassis. Call the Nortel Technical Solutions Center inyour area.

    Verify that the items in the shipping container match those onthe shipment packing list. Use Table 7 "8010co chassis shippingaccessories" (page 32) as a checklist when you verify the contentsof the shipping container.

    Verify that you have all other required hardware.

    Mounting the chassis in a two-post rackMount the 8010co chassis in a standard two-post equipment rack. To installthe 8010co chassis in a 23-in. equipment rack, see the adapter installationinstructions provided by the rack manufacturer.

    In a 7-ft two-post rack, you can install two 8010co chassis platforms and aBIP.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 50 8010co chassis installation

    Prerequisites To mount the 8010co chassis in a two-post rack, you need the following

    equipment: Installation shelf (shipped with the 8010co chassis) A standard 19-in. or 23-in. equipment rack

    Attach the clip nuts shipped with the 8010co chassis, if necessary. 12 Phillips screws and a Phillips screwdriver

    Procedure steps

    Step Action

    1 Place the installation shelf at the bottom of the rack inside the rails.

    2 Hold the installation shelf in position and align the mounting rail withthe two holes on each side of the vertical rack support.

    3 Insert a Phillips screw through each installation shelf mounting holeand into the corresponding hole in the rack.For more information about installing the shelf, see "Installing theinstallation shelf in a 19-in. equipment rack" (page 50).Installing the installation shelf in a 19-in. equipment rack

    4 Add a hex nut to each screw and tighten by using a hex wrench.

    5 Tighten each screw with a Phillips screwdriver.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Mounting the chassis in a two-post rack 51

    6 If the holes in the vertical supports require clip nuts, insert a clipnut in each of the 12 locations.

    WARNINGRisk of personal injuryIt requires three people to lift the 8010co chassis. To make thechassis lighter, remove the modules and power supplies beforeyou lift it.

    7 Lift the 8010co chassis onto the installation shelf.

    8 Hold the 8010co chassis in position and align the flanged end ofthe chassis mounting rail with the six holes on either side of thevertical rack support.For more information about installing the chassis, see "Installing the8010co chassis in a 19-in. two-post rack" (page 52).

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 52 8010co chassis installation

    Installing the 8010co chassis in a 19-in. two-post rack

    9 Make sure that the hole pairs on either side of the vertical supportmatch horizontally.

    10 Tighten each screw with a Phillips screwdriver.

    End

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Mounting the chassis in a Hendry rack 53

    Procedure job aid"Two 8010co chassis with BIP in a two-post rack" (page 53) shows two8010co chassis with a BIP installed in a two-post rack.

    Two 8010co chassis with BIP in a two-post rack

    Mounting the chassis in a Hendry rackMount the 8010co chassis in a Hendry rack.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 54 8010co chassis installation

    Prerequisites To mount the 8010co chassis in a Hendry rack, you need the following

    equipment: Installation shelf (shipped with the 8010co chassis) 12 hex-head screws and a nutdriver A Phillips screwdriver

    Procedure steps

    Step Action

    1 Place the installation shelf at the bottom of the rack.

    2 Hold the installation shelf in position and align the mounting rail withthe two holes on either side of the vertical rack support.

    3 Insert a hex-head screw through the mounting hole of eachinstallation shelf and into the corresponding hole in the rack.For more information about installing the shelf, see "Installing theinstallation shelf in a Hendry rack" (page 54).Installing the installation shelf in a Hendry rack

    4 Tighten each screw with a nutdriver.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Mounting the chassis in a Hendry rack 55

    5 Use a Phillips screwdriver to remove the five screws that secureeach of the two mounting rails to the 8010co chassis.For more information about removing the mounting rails, see"Removing the mounting rails from the 8010co chassis" (page 55).Removing the mounting rails from the 8010co chassis

    6 Use the 10 screws you removed from the two mounting rails toreinstall the mounting rails.For more information about installing the mounting rails, see"Installing the mounting rails for a Hendry rack" (page 56).

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 56 8010co chassis installation

    Installing the mounting rails for a Hendry rack

    7 If the holes in the vertical supports require clip nuts, insert a clipnut in each of the 12 locations.

    WARNINGRisk of personal injuryIt requires three people to lift the 8010co chassis. To make thechassis lighter, remove the interface modules and power suppliesbefore you lift it.

    8 Lift the 8010co chassis onto the installation shelf.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Installing the cable management brackets 57

    9 Hold the 8010co chassis in position and align the flanged end ofthe chassis mounting rail with the six holes on either side of thevertical rack support.Make sure that the hole pairs on either side of the vertical supportmatch horizontally.

    10 Tighten each clip nut with a Phillips screwdriver.

    11 After you secure the 8010co chassis in the rack, you can removethe installation shelf.

    End

    Installing the cable management bracketsInstall the cable management brackets to keep cable clusters fastenedand out of the way but still accessible for maintenance. With the 8010cochassis, you must install a top cable management bracket and two sidecable management brackets.

    Procedure steps

    Step Action

    1 Align the mounting retainers on the inside of the top cablemanagement bracket with the holes on the front of the chassis.For more information about aligning the mounting retainers, see"Installing cable management brackets" (page 58).

    2 Push the sides of the top cable management bracket in place.

    3 Insert and tighten the eight screws by using a Phillips screwdriver tosecure the top cable management bracket to the chassis.For more information about securing the top cable managementbracket, see "Installing cable management brackets" (page 58).

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 58 8010co chassis installation

    Installing cable management brackets

    4 Align the slots on the side bracket with the rods in the chassis.See "Installing cable management brackets" (page 58).

    5 Push the bracket into place.

    End

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Grounding the chassis 59

    Installing 8004DC power supplies with the BIPIf you install the 8010co BIP, the 8010co equipment shelf load and 8004DCpower rating is limited to 732 W for each power supply. Because of thedifference between the 8010co BIP output circuit protection rating of 30 A,and the 8004DC power supply input current rating of 29 A at 48 V DCnominal operating condition, this limitation is required to ensure the productcomplies with the electrical code.

    The BIP (DS1400001) does not support the 8005DC power supply.

    Procedure steps

    Step Action

    1 Install the 8010co chassis as described in previous procedures.

    2 Install the 8004DC power supplies as described in Installing a DCPower Supply in an Ethernet Routing Switch 8000 Series Chassis(NN46205-307; 313070-E)

    3 Install the BIP as described in Installing the Breaker Interface Panelfor the Ethernet Routing Switch 8010co Chassis (312755-G).

    End

    Grounding the chassisNortel recommends that you ground the 8010co chassis before you connectpower cables or network cables to the switch.

    Prerequisites To attach a ground to one of the chassis grounding studs, you need

    the following: one single-hole cable lug that fits over one of the grounding studs a nut and a locking washer for the grounding stud a 6-AWG grounding wire long enough to connect to the ground point 7/16-in. hex wrench to fasten the hardware

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 60 8010co chassis installation

    Procedure steps

    Step Action

    1 Locate the shelf grounding point on the rack. This grounding pointcan be a grounding strip at the back base, top, or side of the rack."Rack grounding strip example" (page 60) shows an example of arack grounding strip. Your rack grounding strip can look differentthan the one shown in this example.

    2 Attach the lug ends of the chassis ground cables to the rackgrounding strip.Use a 7/16-in. hex wrench to fasten the hardware in the correctorder. For more information about attaching the lug ends, see "Rackgrounding strip example" (page 60).Rack grounding strip example

    End

    Procedure job aidThe following figure shows the location of the ground studs on the 8010cochassis rear panel.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Grounding the chassis 61

    Figure 9Location of 8010co chassis ground studs

    The following figure shows an example of how to ground two 8010cochassis and a BIP. In this example, each chassis uses three 8004DC powersupplies. Your rack-grounding strip can look different or can be in a differentlocation than the one shown in the example.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 62 8010co chassis installation

    Figure 10Chassis and 8004DC power supply grounding example

    The following table describes the reference items shown in Figure 10"Chassis and 8004DC power supply grounding example" (page 62).Table 9Item description for chassis and 8004DC power supply groundingItem Description1 Cabinet frame or equipment rack2 AWG 6 ground lead (provided with BIP)3 Upper shelf chassis ground stud

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Grounding the chassis 63

    Item Description4 Upper shelf ground lead (not provided)5 Upper shelf power supply ground leads x 3 (provided with BIP

    option)6 Lower shelf chassis ground stud7 Lower shelf ground lead (not provided)8 Lower shelf power supply ground leads x 3 (provided with BIP

    option)9 Single point ground system10 AWG 6 ground lead (not provided)11 Rack ground strip (example only)

    The following figure shows an example of how to ground two 8010cochassis. In this example, each chassis uses three AC power supplies.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 64 8010co chassis installation

    Figure 11Chassis and AC power supply grounding example

    The following table describes the reference items shown in Figure 11"Chassis and AC power supply grounding example" (page 64)Table 10Item description for chassis and AC power supply groundingItem Description1 Cabinet frame or equipment rack2 Upper shelf chassis ground stud3 Upper shelf ground leads (not provided)

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Grounding the chassis 65

    Item Description4 Lower shelf chassis ground stud5 Upper shelf ground leads (not provided)6 AC equipment ground (ACEG) leads within individual lower shelf

    cords (x 3)7 Single-point ground system8 AWG 6 ground lead (not provided)9 Rack ground strip (example only)10 AC equipment ground (ACEG) leads within individual upper

    shelf cords (x 3)

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 66 8010co chassis installation

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 67

    Switch operationsThis section describes some of the routine tasks you perform to operate theNortel Ethernet Routing Switch 8600.

    For information about operational modes, see Managing PlatformOperations (315545-E).

    Switch operations navigation "Powering on DC power supplies" (page 67) "Powering on AC power supplies" (page 69) "Resetting the switch" (page 70) "Installing removable flash memory cards" (page 70) "Removing removable flash memory cards" (page 72) "Protecting memory card files" (page 73)

    Powering on DC power suppliesPower on the direct current (DC) power supplies to provide power to theswitch.

    Prerequisites If you power on an 8010co chassis with a DC power source and the

    chassis connects to the optional Breaker Interface Panel (BIP), makesure that the circuit breakers on the BIP are in the on position.

    Procedure steps

    Step Action

    1 On each DC power supply, turn the power switch to the on position.If your chassis contains two or three power supplies, turn on thepower supplies simultaneously. If you wait longer to turn on thesecond power supply, one of the power supplies can shut off within

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 68 Switch operations

    7 seconds. To correct this condition, turn off the power supplies fora short period of time, and then turn on the power supplies againsimultaneously.It is not necessary to remove the bezel to turn the power switch on.Do not operate the 8010co chassis with only one power supply. Forinformation about the power switch location, see "DC power supplypower switch" (page 68).DC power supply power switch

    2 Verify that the power output LED for each power supply lights green.

    3 Verify that the power supply status LEDs and the fan LED onthe 8691 Switch Fabric/Central Processor Unit (SF/CPU) or 8692SF/CPU modules light green.

    4 Verify that air flows from the cooling fans out through the back ofthe 8010co chassis.The fan tray red fail LED can light briefly while the fans power tooperational speed.After you turn on the switch, each module automatically initiates adiagnostic test to verify proper module function.

    5 If the power supply LED remains off or if you cannot feel air flowfrom the 8010co chassis vents,on each power supply, turn the powerswitch to the off position.

    6 If you install the 8010co chassis and connect it to the optional BIP,ensure the circuit breakers on the BIP are in the off position.

    7 Wait 1 minute.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Powering on AC power supplies 69

    8 If you install the 8010co chassis and connect it to the optional BIP,turn the circuit breakers on the BIP to the on position.

    9 On each power supply, turn the power switch to the on position.If the problem persists, contact the Nortel Technical Solutions Center.

    End

    Powering on AC power suppliesPower on the AC power supplies to provide power to the switch.

    Procedure steps

    Step Action

    1 Verify that the AC power cords connect to AC power outlets.

    2 On each power supply, turn the power switch to the on position.If your chassis contains two or three power supplies, turn on thepower supplies simultaneously. If you wait longer to turn on thesecond power supply, one of the power supplies can shut off within7 seconds. To correct this condition, turn off the power supplies fora short period of time, and then turn on the power supplies againsimultaneously.Do not operate the 8010co chassis with only one power supply.

    3 Verify the power LED on each power supply lights green.

    4 Verify the power supply status LEDs and the fan LED on the 8691SF/CPU or 8692 SF/CPU modules light green.

    5 Verify air flows from the cooling fans out through the vents of thechassis.The fan tray red fail LED can light briefly while the fans power tooperational speed.

    6 If the power supply LED remains off or if you cannot feel air flowfrom the chassis vents, on each power supply, turn the power switchto the off position.

    7 Wait 1 minute.

    8 On each power supply, turn the power switch to the on position.If the problem persists, contact the Nortel Technical Solutions Center.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 70 Switch operations

    End

    Resetting the switchReset the switch to reboot the switch hardware without cycling power.

    Procedure steps

    Step Action

    1 On the 8691 SF/CPU or the 8692 SF/CPU, press Reset."Reset button" (page 70) shows the location of the Reset button.

    Reset button

    End

    Installing removable flash memory cardsInstall a removable flash memory card in an 8691 SF/CPU module or an8692 SF/CPU module to provide alternative storage media.

    Procedure steps

    Step Action

    1 Position the card with the label facing to the left and the insert arrowpointing toward the card receptacle.For more information about inserting a card, see"Inserting aremovable flash memory card: 8010co chassis" (page 71) and"Inserting a removable flash memory card: 8010, 8006, and 8003chassis" (page 71).

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Installing removable flash memory cards 71

    Inserting a removable flash memory card: 8010co chassis

    Inserting a removable flash memory card: 8010, 8006, and 8003chassis

    2 Insert the card into the card receptacle.

    3 Gently push in the card until it fits tightly in place.

    End

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 72 Switch operations

    Removing removable flash memory cardsRemove a flash memory card from the 8691 SF/CPU module or the 8692SF/CPU module to stop using it as a storage medium.

    Procedure steps

    Step Action

    1 Press the eject button above the memory card receptacle on the8691 SF/CPU module or the 8692 SF/CPU module .The card pops out slightly.For information about removing a card, see "Removing a flashmemory card: 8010co chassis" (page 72) and "Removing a flashmemory card: 8010, 8006, 8003 chassis" (page 73).Removing a flash memory card: 8010co chassis

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Protecting memory card files 73

    Removing a flash memory card: 8010, 8006, 8003 chassis

    2 Pull the flash memory card out of the card receptacle.

    End

    Protecting memory card filesNortel ships each memory card with the read-write protect switch in theunprotected position. After you successfully load the configuration file andsave your configuration, you can write-protect the memory card for backuppurposes.

    Typically, you do not operate a Nortel Ethernet Routing Switch 8600 with awrite-protected memory card. Make a copy of your configuration on anothermemory card, write-protect the second card, and store it in a safe place. Ifyou do not use a second memory card, you can copy your configuration to aFile Transfer Protocol (FTP) or Trivial FTP (TFTP) server.

    Procedure steps

    Step Action

    1 To remove the card, press the eject button above the memory cardreceptacle.

    2 Pull the card out of the card receptacle.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 74 Switch operations

    CAUTIONRisk of data lossYou must remove the card from the 8691 SF/CPU moduleor the 8692 SF/CPU module before you change theread-write protection. Failure to remove the card canresult in improper write protection.

    3 Locate the read-write protect switch on the edge opposite the arrowon the memory card.For information about the location of the read-write protect switch,see "Memory card read-write protect switch" (page 74).Memory card read-write protect switch

    4 Adjust the read-write protect switch.5 To reinsert the card, position the card with the label facing to the left

    and the insert arrow pointing toward the card receptacle.

    6 Insert the card into the card receptacle.

    7 Gently push in the card until it fits tightly in place.

    End

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 75

    TroubleshootingThe following sections provide troubleshooting information for some of themore common problems you may encounter with the Ethernet RoutingSwitch 8000 Series chassis.

    Navigation "LED indications of problems" (page 75) "Apparent module failure" (page 76) "Failure to get a login prompt from the Console port" (page 77) "Cable connection problems" (page 78)

    LED indications of problemsThe following table lists possible problems indicated by the LEDs on theswitch modules and suggests corrective action.

    LED problem indicatorsSymptom Probable cause Corrective actionGreen AC power supplyLEDs are off.

    The switch is not receivingAC power or the powersupply has failed.

    Verify that each AC power cord isfastened securely at both ends andthat power is available at each ACpower outlet. Plug in a device such asa lamp to ensure that the power outletis operational. Verify that each powersupply is turned on.

    The Link/Activity LED for aconnected port is off or doesnot blink (and you believethat traffic is present).

    The switch is experiencinga port connection problem,or the switchs link partneris not auto-negotiatingproperly.

    Verify that the cable connections tothe link partner are correct. Verify portconfiguration parameters for both endsof the connection. Move the cableto another port to see whether theproblem occurs on the new port.

    The Link/Activity LED blinkscontinuously.

    There may be a high trafficload or possible packetbroadcast storm.

    Verify port configuration parametersfor both ends of the connection.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 76 Troubleshooting

    Symptom Probable cause Corrective actionThe Online LED is steadyamber for longer than 3minutes.

    Software incompatibilityexists, or the module cannotcommunicate with themaster module over thebackplane.

    Use the show log command tocheck the system log for indicationsof communication problems. Use theboot command to download a newsoftware image.

    The Master LED on amodule in slot 1 or slot 2 isamber.

    The module has detecteda system clock generationfailure on its own circuitry.

    Replace the module; make sure that itis in the correct slot.

    This LED has significance only for themodule in slot 1 or slot 2 that providesthe clock function for the switch.

    The Fault LED is blinkingamber.

    A chassis failure has beendetected.

    From the console management station,use the show log command to checkthe system log for information abouthardware failures.Check the fan tray to make sure bothfans are running.Check the switch power supplies; onemay have stopped functioning.The module may have failed to readthe MAC address from the chassisbackplane. If this is the case, arrangeto replace the chassis.

    The Fault LED is steadyamber.

    The module failed itspower-on self-test. Adiagnostic or hardwarefailure has been detected.

    Replace the module.

    No LEDs are lit. A hardware failure has beendetected.

    Turn the switch power off and thenturn it on again.

    Apparent module failureIf a module failure occurs, check for possible backplane connectionproblems. Make sure that the module is correctly seated in the backplaneconnector and that the retaining screws are securely tightened.

    If a module fails during module initialization and the replacement module isthe same module type, in rare cases, the new module may not initialize.

    To work around this issue, follow the steps in either workaround 1 or 2.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Failure to get a login prompt from the Console port 77

    Module failure workaround 1

    Step Action

    1 Remove the faulty module.

    2 Insert a module type that is different from the module type removedin Step 1 and wait for this replacement module to initialize.

    3 Remove the module inserted in Step 2.

    4 Insert a new module model in the same slot as the faulty moduleresided. This new module model must be identical to the modulemodel removed in Step 1.

    End

    Module failure workaround 2

    Step Action

    1 Remove the faulty module.

    2 Insert a new module.

    3 Reboot the chassis.

    End

    If the module still fails to operate, contact the Nortel Technical SolutionsCenter for assistance.

    Failure to get a login prompt from the Console portIf you connect a terminal to the Console port of an SF/CPU module andyou fail to get a login prompt, the port may have an incorrect DCE/DTEsetting. Try moving the DCE/DTE switch from its current setting to the otherposition. See the following figure.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 78 Troubleshooting

    Figure 12DCE/DTE switch

    Cable connection problemsPort connection problems are usually traced to a poor cable connection orto an improper connection of the port cables at either end of the link. Toremedy such problems, make sure that the cable connections are secureand that the cables are connected to the correct ports at both ends of thelink.

    10BASE-T cablesCabling for 10BASE-T networks can consist of two-pair Category 3, 4, or5 unshielded twisted pair (UTP) wiring. However, to prepare for futureupgrades to Fast Ethernet, Nortel strongly recommends that you use allCategory 5 cable in your network.

    Ethernet 10BASE-T network installations use cables consisting of two pairsof twisted pair wiresone pair to send data and one to receive data. Thesewires must connect to another 10BASE-T station that has the sending pairattached to its receiving pair and vice versa. If the two nodes are wiredalike, they both attempt to send data out on the same RJ-45 pins. In such acase, a straight-through cable does not work. However, a crossover cableoperates normally.

    The 8648TXE, 8648TXM, and 8632TXE modules are designed to haveEthernet network interface cards (NICs) connect directly to their RJ-45 portsusing straight-through cables. NICs port types are MDI. However, if an8648TXE, 8648TXM, or 8632TXE module must connect to a hub or anotherswitch that follows usual conventions, a crossover cable is required becausethe port types are MDI-X. You only need crossover cables when connectingcables to devices that have the same port type.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • Cable connection problems 79

    100BASE-T and 1000BASE-T cablesThe 100 Mbit/s ports and 1 Gbit/s ports are designed to operate usingCategory 5 UTP cabling only. To minimize crosstalk noise, maintain the twistratio of the cable up to the point of termination; untwist at any terminationcannot exceed 0.5 in. (1.27 cm).

    GBIC cablesCables for the GBICs vary depending on the specific GBIC type. Forinformation about the cable requirements for GBICs, see Installing SFP andXFP Transceivers and GBICs (NN46205-305; 318034-D).

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 80 Troubleshooting

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 81

    Common proceduresThis section describes common procedures when you install the chassis.

    Reducing the chassis weightReduce the chassis weight to make the chassis easier to lift and thus reducethe risk of personal injury or equipment damage.

    Procedure steps

    Step Action

    1 Remove the power supply filler panels.For more information, see Installing and AC Power Supply in theEthernet Routing Switch 8000 Series Chassis (NN46205-306;312751-E) or Installing a DC Power Supply in an Ethernet RoutingSwitch 8000 Series Chassis (NN46205-307; 313070-E).

    2 Remove the module filler panels.For more information, see Installing Ethernet Routing Switch 8600Modules (NN46205-304; 312749-K).

    3 Remove the fan trays.For more information, see Installing a Fan Tray in an EthernetRouting Switch 8000 Series Chassis (312752-E).

    End

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 82 Common procedures

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 83

    Part numbersThe following table lists Nortel Ethernet Routing Switch 8600 hardwareand part numbers.

    Part number

    Item Additional details

    DS1400001

    8010co chassis Breaker Interface Panel(BIP)

    Support for one or two 8010co chassis.Includes rack level alarms and cablingfrom BIP to chassis.

    DS1402001

    8010 10-slot chassis Includes chassis, dual backplane, twofan trays, RS232 cable for managementconsole, rack-mount kit, and cablemanagement bracket kit.

    DS1402002

    8006 6-slot chassis Includes chassis, dual backplane, fan tray,RS232 cable for management console,rack-mount kit, and cable managementbracket kit.

    DS1402003

    8003 3-slot chassis Includes chassis, fan tray, RS232 cablefor management console, rack-mount kit,and cable management bracket kit.

    DS1402004

    8010co 10-slot NEBS chassis Includes chassis, fan trays, RS232 cablefor management console, rack-mount kitand cable management bracket.

    DS1405007

    8004DC 850 W power supply

    DS1405A03

    8003ACPS 100-240 V AC power supply Does not include power cord.

    DS1405B03

    8003ACPS 100-240 V AC power supply Includes European Schuko power cord.

    DS1405C03

    8003ACPS 100-240 V AC power supply Includes power cord used in the UK andIreland.

    DS1405D03

    8003ACPS 100-240 V AC power supply Includes power cord used in Japan.

    Nortel Ethernet Routing Switch 8600Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis

    NN46205-303 01.02 Standard4.1 10 January 2008

    Copyright 2008, Nortel Networks.

  • 84 Part numbers

    Part number

    Item Additional details

    DS1405E03

    8003ACPS 100-240 V AC power supply Includes North American power cord.

    DS1405F03

    8003ACPS 100-240 V AC power supply Includes Australian power cord, also usedin New Zealand and the PRC.

    DS1405A08

    8004AC 100-240 V AC power supply Does not include power cord.

    DS1405B08

    8004AC 100-240 V AC power supply Includes European Schuko power cord.

    DS1405C08

    8004AC 100-240 V AC power supply Includes power cord used in the UK andIreland.

    DS1405D08

    8004AC 100-240 V AC power supply Includes power cord used in Japan.

    DS1405E08

    8004AC 100-240 V AC power supply Includes North American power cord.

    DS1405F08

    8004AC 100-240 V AC power supply Includes Australian power cord, also usedin New Zealand and the PRC.

    DS1411001

    Spare fan tray for 8010 10-slot chassis

    DS1411002

    Spare fan tray for 8006 6-slot chassis

    DS1411006

    Spare fan tray for 8010co 10-slot NEBSchassis

    DS1