19
· · · Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow the sections that pertain to your particular installation. This will help you avoid costly mistakes. In addition to proper installation, read all operating and safety instructions. All information is based on the latest product information available at the time of publication. Kohler China Ltd. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. These instructions contain important care, cleaning, and warranty information-please leave these instructions for the consumer. BEFORE YOU BEGIN BEFORE YOU BEGIN · · · · · · · INSTALLATION INSTRUCTIONS BUBBLE MASSAGE BATH K-18212T-G1/G2, K-1709T-G1/G2 ODEON OVE A. Ordering Information ODEON Bubble Massage Bath, L/Drain....K-18212T-G1 ODEON Bubble Massage Bath, R/Drain ...K-18212T-G2 OVE Bubble Massage Bath, L/Drain ...........K-1709T-G1 OVE Bubble Massage Bath, R/Drain...........K-1709T-G2 A. ...........................K-18212T-G1 ...........................K-18212T-G2 ................................K-1709T-G1 ................................K-1709T-G2 ROUGHING-IN & DIMENSIONS ROUGHING-IN & DIMENSIONS B. 220~240 5.1 50 A (GFCI) B. Required Electrical Service 220~240V 5.1A 50Hz. Dedicated branch circuit required, protected with Class A Ground-Fault Circuit-Interrupt (GFCI): Pump , 2008 Copyright Kohler China Ltd., 2008 -1- 368 201419 1061639-T01-C

ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

Embed Size (px)

Citation preview

Page 1: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

Please read these instructions carefully to

familiarize yourself with the required tools, materials,

and installation sequences. Follow the sections that

pertain to your particular installation. This will help

you avoid costly mistakes. In addition to proper

installation, read all operating and safety instructions.

All information is based on the latest product

information available at the time of publication.

Kohler China Ltd. reserves the right to make

changes in product characteristics, packaging, or

availability at any time without notice.

These instructions contain important care, cleaning,

and warranty information-please leave these

instructions for the consumer.

BEFORE YOU BEGINBEFORE YOU BEGIN

INSTALLATION INSTRUCTIONS

BUBBLE MASSAGE BATHK-18212T-G1/G2, K-1709T-G1/G2

ODEONOVE

A. Ordering Information

ODEON Bubble Massage Bath, L/Drain....K-18212T-G1ODEON Bubble Massage Bath, R/Drain ...K-18212T-G2OVE Bubble Massage Bath, L/Drain ...........K-1709T-G1OVE Bubble Massage Bath, R/Drain...........K-1709T-G2

A.

...........................K-18212T-G1

...........................K-18212T-G2................................K-1709T-G1................................K-1709T-G2

ROUGHING-IN & DIMENSIONSROUGHING-IN & DIMENSIONS

B.

220~240 5.1 50

A(GFCI)

B. Required Electrical Service

220~240V 5.1A 50Hz.

Dedicated branch circuit required, protected withClass A Ground-Fault Circuit-Interrupt (GFCI):

Pump

, 2008

Copyright Kohler China Ltd., 2008-1-

368 201419

1061639-T01-C

Page 2: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

Fixture*: Basin Area Top Area Weight

Bathing Well

* Approximate measurements for comparison only.

1412 751mm1098 492mm

To Overflow 458mm 208L

Water depth Capacity

*

458 208

*

1412 7511098 492

K-18212T-G1/G2

C. Product Information C.

Blowermotor:

Heater

300 W

Voltage Frequency Amperage

220~240 V 50 Hz 5A1 HP 300 W 220~240 V 50 Hz 5A1

D.

Read the entire installation instructions beforebeginning the installation.

D. Installation

1092 427 1585 625

*

327 214

Fixture*

Bathing well

To overflow

* Approximate measurements for comparison only.

Basin area

1092 427mm 1585 625mm

Water depth

327mm

Top area

Capacity

214L

Weight

33.5kg

K-1709T-G1/G2

E.E. Dimensions

Unit: mm: mm

K-18212T-G1/G2

Blowermotor:

Heater

300 W

Voltage Frequency Amperage

220~240 V 50 Hz 5A1 HP 300 W 220~240 V 50 Hz 5A1

-2-

32.534.3

27580.8

50

1525

34.3

820

45.552

465

100

500

K-18212T-G1

K-18212T-G2

5052

31.8kg 31.8

33.5

1061639-T01-C

Page 3: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

K-1709T-G1/G2 Unit: mm: mm

PRODUCT NOTICES

A.

(GFCI)

A. Installation Hazard Notification

DANGER: Risk of fire, electric shock, or injury toPersons.

WARNING: Risk of electrical shock.

WARNING: Risk of electrical shock.

WARNING: Risk of electrical shock.

WARNING: Risk of injury or property damage.

NOTICE:WARNING: Keep the area around the blowermotor clean and free of debris.

Read important safety instructions oninside front cover of these instructions.

A licensedelectrician should make all electrical connections.

Connectonly to a circuit protected by a Ground-FaultCircuit-Interrupter (GFCI) or Earth-LeakageCircuit-Breaker (ELCB).

Disconnect power before servicing.

Please read all instructions thoroughly beforebeginning installation, including the followingProduct Requirements.

Follow all local plumbing and electrical codes.

Ensure that thearea around the blower motor is free of sawdust,insulation, dirt, or other small loose debris. Suchmaterial could clog the blower motor air ductsand reduce the air flow through the blower.

-3-

43

457

470

84 52

50

333

1700

750

K-1709T-G1

K-1709T-G2

1061639-T01-C

Page 4: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

B. Factory-Assembled Features

Factory installed components include blower motor withpower supply cord, check valve, air piping, userkeypad, and keypad cable. Other than power wiringand plumbing, no assembly is needed.

Do not relocate theblower motor, or make other modifications to thesystem in the absence of kit instructions, as thiscould adversely affect the performance and safeoperation of the bath with airjets. Kohler Chinashall not be liable under its warranty or otherwisefor personal injury or damage caused by anysuch unauthorized modification.

WARNING: Unauthorized modification maycause unsafe operation or affect performanceof the bath with airjets.

B.

PRODUCT REQUIREMENTS

B. Plumbing Specifications

If using a rim-mounted bath faucet, flexible connections

between the valves and spout may be required.

Confirm adequate mounting, connection space of

specified faucet for your installation.

Confirm adequate support for the faucet; large faucets

that may inadvertently used as a means of support are

not appropriate or safe or this installation.

B.

A. Summary Of Key Requirements

Observe all local plumbing codes.

Install the unit to a level subfloor.

Provide properly-dimensioned framing.

Baths with airjets are designed for a variety ofinstallations, depending upon the model chosen.

A.

C. Product Inspection

Carefully unpack and inspect the bath with airjets for

damage. Leave all materials in the carton during

constructions to prevent damage.

C.

D. Electrical Requirements

The installation must have a Class A Ground-Fault

Circuit-Interrupter (GFCI). The GFCI protects against

Line-to-ground shock hazard. Use a 220-240 V, 10 A

(minimum), 50 Hz dedicated service for the bath with

airjets.

D.

A (GFCI) GFCI220-240 10

( ) 50

-4-1061639-T01-C

Page 5: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

INSTALLATION REQUIREMENTSINSTALLATION REQUIREMENTS

Adjustable pipewrench

Rule

Level

Safety shoes

Safety glasses

Square

Screwdriver

Pliers

Utility knife

Pencil

Measuring Tape

Plus:

Conventional woodworking tools and materials orconventional bricklaying tools and materials

Drop Cloth

Construction adhesive (optional)

Cement or mortar (optional)

2x4's or 2x6's

:

� � �

� � �

� 2x4' 2x6'

Plumbers putty

Wall coverings, as necessary

Silicone sealant

Gypsum cement (optional)

Construction adhesive

(optional)

Protective covering for

bathtub

Nails

Silicone Sealant

B. Materials RequiredA. Tools Required

( )

( )

( )

B.A.

Old BathFloor Protection Boards

SITE REQUIREMENTSSITE REQUIREMENTS

A.

A. Old Bath Removal (If Applicable)

Disconnect the drain at the trap. Remove the old wallmaterial. Slip boards under the old bath feet to protectthe floor, and slide the old bath out of the recess asillustrated.

-5-1061639-T01-C

Page 6: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

B.Prepare the Site

CAUTION: Risk of product damage.

NOTICE:

NOTICE:

Do not

support the bath by the rim.

Unless otherwise specified, floor supportunder the bath must provide for a minimum of 80lbs./square foot (390 kg./square meter) loading.

Provide adequate ventilation and a minimumof 15 cubic feet (.4 cubic meters) in the installedlocation for cooling the motor and to supply sufficientair for the blower. Do not install the blower motor closerthan 2.5mm from the wall or other objects.

Make sure the flooring offers adequate support foryour bath, and verify that the subfloor is flat andlevel.

This bath may be installed in a drop-in or in anisland installation. An island installation requires afour side surround. In both instances, make sure thedeck is supported by brick or concrete.

Install an access panel to allow the blower to beserviced. Jalousie access is recommended.

Construct brick or concrete supports.

Provide a 2mm gap between the bath rim and theconcrete or brick framing. Frame the floor, orconstruct a frame for a raised installation, inaccordance with the roughing-in information packedwith the bath.

B.

80 / (390 / )

5000 15 (0.4

)

25

2

Approved Tile Backing

Typical

Bath

2 mm

TileBrick

access

panel

Approved Tile Backing Install an access panel to allowthe pump to be serviced.

Bath may be installed next to thewall or as an island installation.

TileBrick

-6-1061639-T01-C

Page 7: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

C. Whirlpool Area ConstructionPreparation (Optional)

Make sure you allow for access to the pump in the

event the unit requires service. When constructing the

framing, allow for the thickness of sub and finish wall

material (e.g. mortar mix and ceramic or marble tilling).

C. ( )

(

)

Drop In Installation Refer to rough-in notes on page 2for cut-out details. Make sure the whirlpool is supportedby the supporting feet on the bottom of the whirlpool.Do not hang the bath by the rim.

2

Bath Rim

1/ 5" (2mm) GapBetween Bath Rimand Framing

2

1

A.

B.

Your new whirlpool has been manufactured to the

highest possible standards, it has been factory tested

and approved.

When removing bath from protective carton

. Inspect for any

possible damage that may have occurred in transit.

Position a clean drop cloth or similar material in the

bottom of the bath to pretect the finish. Be careful

not to scratch the surface of the bath.

DO

NOT LIFT BATH BY PIPE WORK

A.

B.

BEFORE INSTALLING WHIRLPOOLBEFORE INSTALLING WHIRLPOOL

C.

C.

Identify motor access location before proceeding with

installation.NOTE NO MOTOR ACCESS NO WARRANTYSERVICE. Ventilation must be provided in order toallow heat from motor to dissipate.

PROVIDE MOTOR ACCESS AS SHOWN.

Jalousie access isrecommended.

Blower Access

Control Panel Access

-7-1061639-T01-C

Page 8: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

D. IMPORTANT: Bath must be installed level on all top

edges.

D.

E. Install the drain to the bath according to the drain

' Do not connect the trap atthis time.manufacturer s instructions.

E.

1

2

3

4

5

9

7 8 13

10

11

12 9a

SILICONE

Smear with SILICONE

9b

6

Bath

14

15

16

17

F. Partially Install Bath Drain F.

Unpack drain (17295T-CP) and ensure that the ControlCable is not twisted or awkwardly bent.Please ensure that the bath is placed on woondenblocks or bricks to protect the waste body under thebath.

Installation steps:

1) Fit to

2) Insert into hole in bath from upper side.

3) Fit to and

to underside of bath.

4) to by means of

..

Drain Gasket Thin Strainer

Strainer

Drain Gasket Thick Drain Body Assy

Drain Body Assy

Strainer Drain Body Assy Fix

Screw Strainer Do not tighten firmly at thisstage

Ý

5 4

4

6 9

9

4 9

3

9b

(17295T-CP)

1)

2)

3)

4)

Ý

9b

5

4

4

6 9

4 93

-8-1061639-T01-C

Page 9: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

5) Apply a bead of silicone around the overflow hole, onthe outside of the bath. Smear with silicone the insidewall of overflow hole as illustrated.

Gasket Overflow Over Flow Body

Overflow CoverControl CableOverflow Cover

6) Fit 2nd. toand offer this assembly to back of overflow opening,ensuring they are centrally positioned and thenscrew on to central spindle .

is not twisted before fully tightening. In the event that the Control

Cable is twisted or jammed, the pop-up mechanismwill not operate.

9b

12

9a

12

14

9b

12

9a

12

5)

( )

6) 14

7 8

2

1

7) Centralise Grating with Waste Body by liningup ribs of each directly in line and tighten Fixing

Screw with a coin or suitable screwdiver.- handtight plus 1/4 turn should

be sufficient.

8) Adjust Plug by twisting Control Knob to the 'up'position and then fix Plug height by use of Adjusting

Screw .9) Secure Flexible Pipe by tightening Compression

Nut against Compression Seal .10) Set drain pipe , put on nut drain pipe , and then

tighten gasket .Check if the pop-up mechanism is operating correctly.If it doesn't the Plug height still needs adjusting orControl Cable might be twisted or jammed. Proceedwith bath installation only after you've ensured thedrain is operating correctly.

Do not overtighten

13

7)

-----

8)

9)

10)

13

16 17

15

16 17

15

4 9

3

10

4 9

3

101

2

78

-9-

CAUTION: Risk of product damage.

CAUTION: Risk of product damage.

Do not liftthe bath with airjets by the air channels or blowermotor, or use the air channels or blower motorfor structural support of the bath.

Do notsupport the bath by the rim.

If the subfloor is not level, shim the bath support blocksas necessary.

INSTALL THE BATHINSTALL THE BATH

1061639-T01-C

Page 10: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

A. Option Using a Cement or Mortar Bed

NOTE: Do not use gypsum cement or drywallcompound for this application, as they will not providean acceptable, durable bond.

Spread a 50mm thick layer of cement or mortar onthe subfloor where the bath will be set. This will helpsecure, level, and support the unit. Clear all thematerial away from the support block locations.

Position a piece of plastic drop cloth material on topof the cement or mortar bed.

With help, carefully lift the bath into place, and makesure the support blocks do not rest in the bedMaterial.

Insert the drain tailpiece into the trap. Make sure thebath is level and resting on all support blocks.

Remove the protective tape from the rim.

A.

50

Spread a 51mm Layerof Cement orMotarBed Materiral.

51mm

Clear spacesfor support blocks.

-10-

B. Option Using Construction Adhesive

Apply a generous amount of high-quality

construction adhesive to the bottom of the support

blocks.

With help, carefully lift the bath into position.

Insert the drain tailpiece into the trap. Make sure the

bath is level and resting on all support blocks.

Remove the protective tape from the rim.

B.

Apply Constructionadhesive to theSupport Blocks.

1061639-T01-C

Page 11: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

C. Option Using Silicone Sealant

With help, Carefully lift the bath into position.

Insert the drain tailpiece into the trap. Make sure thebath is level and resting on all support blocks.

Remove the protective tape from the rim. Apply acontinuous bead of high-quality silicone sealantaround the entire rim of the bath.

Allow the sealant to cure according to themanufacturer s instructions.'

C.

Bath Rim

1/16" (2mm) GapBetween Bath Rimand Framing

2

D. Install the Plumbing

CAUTION: Risk of property damage.

NOTICE:

Ensure awatertight seal on the bath drain.

Connect the drain to the trap according to the

An access panel will simplify futuremaintenance.

Install the fa

kage.

manufacturer s instructions.

ucet valving according to the faucetmanufacturer s instructions. Do not install the faucettrim until instructed. Open the hot and cold watersupplies, and check the supply connections forleakage.

Run water into the bath, and check the drainconnections for lea

'

'

D.

-11-1061639-T01-C

Page 12: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

E. Make Electrical Connections

WARNING: Risk of electric shock.

NOTE:

To reduce

the risk of electrical shock, connect the blower

motor to a properly grounded, grounding-type

receptacle protected by Ground-Fault Circuit-

Interrupters (GFCI s). Do not remove the plug

grounding pins. Do not use grounding adapters.

The bath with airjets model number is printed

on a label near the blower motor. This label also

identifies the electrical rating.

Your Kohler bath with airjets is equipped with a cord

and plug. The blower motor has been wired at the

factory. A licensed electrician must install a

dedicated GFCI-protected, 220 V, 10 A, grounded

outlet. Locate the outlet behind the bath, and within

610mm of the blower motor.

Plug the blower motor into this outlet.

Clean the area of all dust and debris.

'

E.

GFCI

220 10 GFCI

610

Blower Motor

GFCI-Protected Receptacle

-12-1061639-T01-C

Page 13: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

F. Test Run the Bath with Airjets

For information on unit operation, refer to the"Confirm Proper Operation" section.

Check all electrical connections, and make sure theelectrical power to the bath with airjets is on.

Make sure all piping connections in the air harnessare secure.

Verify that the blower motor is secure.

Temporarily remove the plastic drop cloth or otherprotective sheeting from the bath.

Fill the bath to a level at least 50mm above the topof the highest airjet.

Check the drain piping for leaks. Repair any leaks.

Operate the bath and check for air flow through theairjets. Check the air piping for air leaks.

Stop the bath and drain the water.

Return the plastic drop cloth or other protectivesheeting to the bath.heck the drain connections forleakage.

F.

50

Purge Mode

On/Off/

Increases Flow

Decreases Flow

Finished tiled Wall

Brick orConcrete Wall

Bath

Silicone Filler

Paste Mortar

G. Drop-In Models:

CAUTION: Risk of product damage. Do not

support the weight of the bath by the rim.

For sunken type installation, construct the ceramic or

marble tiles. Seal the joints between the bath rim and

the tiled wall with silicone sealant.

G.

-13-1061639-T01-C

Page 14: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

H.

/12mm 6mm 1800 / 12mm 900

600

H. Drilling And Cutting Acrylic

DRILLING:

NOTE:

CUTTING:

Small holes can be drilled with a twist drill,but the cutting edge MUST be backed off with an oilstone (the sharp edge dulled). Large holes must bedrilled with a hole saw. Maximum drill size-12mm. Drillspeeds-6mm 1800 RPM-12 mm 900 RPM.

Always drill from acrylic surface.

If for any reason the acrylic requires cutting,use a fine tooth hacksaw and proceed with caution.Edges can be smoothed with a second-cut file andmedium-fine sandpaper. If the surface of the acrylicshould happen to be damaged, it can be restored bypolishing with an abrasive cleaner. Deep scratches canbe removed by rubbing with 600 grade wet & drysandpaper then polishing.

A.

BATH OPERATIONBATH OPERATION

A. Fill the Bath

CAUTION: Risk of product damage.

NOTE:

Ensurethat the area around the blower motor is free ofsawdust, insulation, dirt, or other small loosedebris. Such material could clog the blowermotor air ducts and reduce the air flow throughthe blower motor.

Please read these steps carefully before youoperate your bath with airjets. Troubleshoot anyproblems using the "Troubleshooting" section.

I. Clean-Up After Installation

Clean the area around the blower motor of all dust

and debris.

Use warm water and a liquid detergent to clean the

surface of the bath with airjets.

, as they may scratch and dull

the surface.

Solid substances could block the airjets.

Chemically active cleaning solutions can damage

the bath surface. Refer to the homeowners guide for

normal cleaning recommendations.

Do not use

abrasive cleansers

Do not use powdered cleaners

unless the cleaner is fully issolved in water.

Do not use

bleach or ammonia cleaning solutions.

I.

-14-1061639-T01-C

Page 15: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

B. Keypad Operation

On/Off -

Purge Mode -

Increases Flow -

Decreases Flow-

Turns the blower motor on and off.

Pressing the switch once starts the blower motor at

a midrange speed. Pressing the button again stops

the blower motor. The blower motor automatically

stops after about 20 minutes of operation. The

blower motor can be restarted by pressing the

On/Off button.

Initiates the purge cycle manually.

The purge cycle blows any residual water out of the

air channels after the bath has been drained.

Pressing the button once starts the blower motor at

low-speed. The blower motor stops automatically

after about two minutes. Pressing the button again

before the cycle ends will stop the blower motor.

Note that this product also has an automatic purge

cycle, which initiates about 30 minutes after the

blower has stopped.

Increases the air flow.

Decreases the air flow.

B.

/

20 /

2

30

C. Preliminary Checks

Temporarily remove all access panels.

Verify that the union connection at the check valve issecurely hand tightened.

Verify that the screws are installed in the PVC airpiping at the blower motor and at the check valve.

Verify that cable ties support the air piping.

Verify that the blower motor is secure.

Verify that the keypad cable is securely connectedat the user keypad and at the blower motor.

Fill the bath to a level at least 50mm above the topof the highest airjet.

C.

PVC

50

Purge Mode

On/Off/

Increases Flow

Decreases Flow

-15-1061639-T01-C

Page 16: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

D. Confirm Air System Operation

Press the power button on the user keypad.

Observe that the blower motor starts at a midrange

speed.

Observe that air is blowing through all of the airjets.

Press the up button on the user keypad.

Verify that the air flow increases.

Press the down button on the user keypad.

Verify that the air flow decreases.

Press the power button on the keypad to stop the

blower motor.

D.

E. Confirm Manual Purge Operation

Drain the bath.

When the bath has drained, press the purge buttononce.

Observe that the blower motor starts at low speedand blows any residual water from the air channels.

Observe that air comes out of the airjets.

Verify that pressing the purge button again stops theblower motor.

Press the purge button to restart the manual purge.

Observe that the blower motor stops automaticallyafter about two minutes.

F. Confirm Automatic Purge Operation

Press the power button.

Press the power button again to turn off the blower.

Note the time.

If filled, drain the bath.

Observe that the blower motor starts in the purge

cycle after about 30 minutes.

Observe that the blower motor stops automatically

after about two minutes.

E.

F.

30

-16-1061639-T01-C

Page 17: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

SYMPTOMS PROBABLE CAUSES RECORRECTIVE ACTION

1. Bath with airjets does notstart.

A. No power to blower motor.

2. Blower motor starts, butthere are few or no bubbles.

3. Bath stops automaticallybefore 18 minutes.

B. User keypad cable loose or damaged.

C. User keypad does not work.

D. Blower motor does not work.

A. Set/reset GFCI or ELCB breaker;check wiring.

B. Check wire connections. If necessary,replace user keypad cable.

C. Check wire connections.Replace user keypad.

D. Replace blower motor.

A. Blower motor is disconnected.

B. Blower motor air flow is restricted.

A. Connect blower motor to air harness.

B. Clean the area around the blowermotor. Ensure adequate ventilation.

A. GFCI or ELCB trips.

B. Motor overheated and protectiondevice activated.

A. Identify source of fault and correct.

B. Check for blockage at motor vents.Remove blockage and allow motor tocool.

A. Replace blower motor.

A. Check wire connections. If necessary,replace user keypad cable.

B. Replace user keypad.

C. Replace blower motor.

A. Replace blower motor.

4. Bath does not stopautomatically after 22minutes.

5. Blower motor does not stopwhen power button on userkeypad is pressed.

6. Blower motor operates butvariable speed feature doesnot work.

7. Automatic purge cycle doesnot occur.

A. Blower motor does not work.

A. User keypad cable loose or damaged.

B. User keypad does not work. B. Replace user keypad.

A. User keypad cable loose or damaged.

B. User keypad does not work.

C. Blower motor does not work.

A. Check wire connections. If necessary,replace user keypad cable.

A. Blower motor does not work.

8. Manual purge cycle doesnot Work.

A. User keypad cable loose or damaged.

B. User keypad does not work.

C. Blower motor does not work.

A. Check wire connections. If necessary,replace user keypad cable.

B. Replace user keypad.

C. Replace blower motor.

-17-1061639-T01-C

Page 18: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

1.

2.

3. 18

4. 22

5.

6.

7.

8.

A.

B.

C.

D.

A.

B.

A.GFCI ELCB

B.

A.

A.

B.

A.

B.

A.

A.

B.

C.

A. / GFCI ELCB

B.

C.

D.

A.

B.

A.

B.

A.

A.

B.

A.

B.

A.

A.

B.

C.

*

* 2

Mequiars 28 ( )

( )

IMPORTANT CONSUMER INFORMATIONIMPORTANT CONSUMER INFORMATION

Consumer Responsibilities

Please confirm that the bubble massage bath is

installed according to the installation instructions.

Massage system should be used at least once a month

to avoid the possibility that the electrical fittings be

damaged because of excessive moisture.

Cleaning Acrylic Surfaces: Do not use abrasive

cleansers on any acrylic surfaces, as they will scratch

and dull the surface. Wipe out the bath after each use

to prevent a build-up of soap and scum.

If the acrylic surface becomes dull, an automotive type

rubbing compound may be used on the unit, followed

by an application of paste wax.

We recommended:

Rubbing compound mequiars mirror glaze 28 metal

polish (import product) or "green oil".

-18-1061639-T01-C

Page 19: ODEON OVE - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k18212tg10.pdf · INSTALLATION REQUIREMENTSINSTALLATIONREQUIREMENTS Adjustable pipe wrench Rule Level Safety shoes

* /* Color code must be specified when ordering.

1033944Cable

1081385Blower Controller

1032493-FJCustomer Interface

1034122-FJCheck Valve

1081337Air Blower

BUBBLE MASSAGE BATHK-18212T-G1/G2, K-1709T-G1/G2

ODEONOVE

SERVICE PARTS PAGE

-19-1061639-T01-C