196
JDSU Optical FiberCable OFS-200 Software Fiber Optic PC processing tools, Release 4.40 User Manual

Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Embed Size (px)

Citation preview

Page 1: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

JDSU Optical FiberCable OFS-200 SoftwareFiber Optic PC processing tools, Release 4.40

User Manual

Page 2: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05
Page 3: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

JDSU Optical FiberCable OFS-200 SoftwareFiber Optic PC processing tools, release 4.40

User Manual

Page 4: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05
Page 5: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Notice Every effort was made to ensure that the information in this document was accurate at the time of printing. However, information is subject to change without notice, and JDSU reserves the right to provide an addendum to this document with information not available at the time that this document was created.

Copyright © Copyright 2006 JDSU, LLC. All rights reserved. JDSU, Enabling Broadband & Optical Innovation, and its logo are trademarks of JDSU, LLC. All other trademarks and registered trademarks are the property of their respective owners. No part of this guide may be reproduced or transmitted electronically or otherwise without written permission of the publisher.

Trademarks JDSU is a trademark of JDSU in the United States and other countries.

Microsoft, Windows, Windows CE, Windows NT, MS-DOS, Excel, Word and Microsoft Internet Explorer are either trademarks or regis-tered trademarks of Microsoft Corporation in the United States and/or other countries.

Pentium is a trademark or registered trademark of the Intel Corpora-tion in the United States and/or other countries.

IBM is a trademark of International Business Machines Corporation.

Specifications, terms, and conditions are subject to change without notice. All trademarks and registered trademarks are the property of their respective companies.

Available manuals This guide is a product of JDSU's Technical Information Development Department.

This manual gives you the main information to install, start and use the FiberCable OFS-200 software.

It is only delivered in pdf format, with the software, on the CD-ROM.

FiberCable Manual 7OFSMAN12/05 v

Page 6: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

vi FiberCable Manual 7OFSMAN12/05

Page 7: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Table of Contents

About This Guide xviiAbout the FiberCable software . . . . . . . . . . . . . . . . . . . . . . . . .xviiiAbout the Platform 6000/8000 . . . . . . . . . . . . . . . . . . . . . . . . . . xviiiTechnical assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xviiiConventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix

Chapter 1 Installation 1Software requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Hardware requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Installing the software on your PC . . . . . . . . . . . . . . . . . . . . . . . . 2

First installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Modifying or upgrading your installation . . . . . . . . . . . . . . . . . . . . 4Removing the software from your PC . . . . . . . . . . . . . . . . . . . . . . 4

Chapter 2 Generalities 5Opening trace files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Trace file sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Opening a file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Opening several files in the same window . . . . . . . . . . . . . . . . . 7

FiberCable Manual 7OFSMAN12/05 vii

Page 8: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Table of Contents

Files conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Converting several «WTK» files into «SOR» . . . . . . . . . . . . . . . 7Converting several «SOR» or «TFW» files to the «WTK» format 8

File Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8To save your work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Delete Trace(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Printing trace and results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9To select your printer and printing optins . . . . . . . . . . . . . . . . . . . . 9To Setup the page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Mosaic setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Multi-traces printout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

To Preview the printing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13To Print the Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Mosaic page layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Chapter 3 Remote control of the MTS 15Remote Control menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Configuration of a MTS <-> PC link . . . . . . . . . . . . . . . . . . . . . . . 16Connection of the MTS to the PC . . . . . . . . . . . . . . . . . . . . . . . . . 17

Connection via the Ethernet interface . . . . . . . . . . . . . . . . . . . . . 17Connection via the RS232 interface . . . . . . . . . . . . . . . . . . . . . . 18Local connection via ppp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Connexion via existing ppp . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Create a new connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Disconnecting the MTS from the PC . . . . . . . . . . . . . . . . . . . . . . 23Transfer of files MTS <-> PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

File transfer from the PC to a remote MTS . . . . . . . . . . . . . . . . 24File transfer from the MTS to the PC . . . . . . . . . . . . . . . . . . . . . 25Possible actions on the selected files on PC or MTS . . . . . . . . 25Leaving the transfer menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Remote Control of a measurement on the MTS . . . . . . . . . . . . . 26Acquisition of an OTDR trace . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Acquisition of an optical spectrum . . . . . . . . . . . . . . . . . . . . . . . . 27

Storing traces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Format for OTDR traces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Format for optical spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Naming files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Automatic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Semi-automatic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

viii FiberCable Manual 7OFSMAN12/05

Page 9: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Table of Contents

Chapter 4 Displaying Traces 33Traces display window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

The menu and tool bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35The trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Trace parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Customize the job parameters . . . . . . . . . . . . . . . . . . . . . . . . . 36OTDR parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37WDM / OSA parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38PMD parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38CD parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39ATS parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40FOX parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Specfic information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Moving between events (OTDR) . . . . . . . . . . . . . . . . . . . . . . . . . 40Actions on traces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Grid (OTDR / WDM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Display Zoom Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Zoom-in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Zoom out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Vertical or horizontal zoom . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Reset the zoom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Predefined zoom (OTDR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Using the maximum display area . . . . . . . . . . . . . . . . . . . . . . . . 43Displaying the Results / Alarms table . . . . . . . . . . . . . . . . . . . . . 44Trace Shift (OTDR / WDM-OSA) . . . . . . . . . . . . . . . . . . . . . . . . . 44

OTDR Trace shift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Vertical shift for WDM / OSA traces . . . . . . . . . . . . . . . . . . . . . 46

Cursors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Mouse pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Cursors A and B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Positioning A and B cursors . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Cursor selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Tooltips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Trace information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Setting Display Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Display preferences for OTDR traces . . . . . . . . . . . . . . . . . . . . . 50Display preferences for WDM/OSA traces . . . . . . . . . . . . . . . . . 51Display preferences for PMD traces . . . . . . . . . . . . . . . . . . . . . . 52Display preferences for CD traces . . . . . . . . . . . . . . . . . . . . . . . 52Display preferences for ATS traces . . . . . . . . . . . . . . . . . . . . . . . 53Display preferences for fox results . . . . . . . . . . . . . . . . . . . . . . . 53

Displaying open trace files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

FiberCable Manual 7OFSMAN12/05 ix

Page 10: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Table of Contents

Navigating between open files . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Displaying more than one file at a time . . . . . . . . . . . . . . . . . . . . 54

In tile and cascade mode display . . . . . . . . . . . . . . . . . . . . . . . 54Displaying Multi traces (OTDR / WDM -OSA) . . . . . . . . . . . . . . 54

Removing a trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56To copy the trace to a word processing file . . . . . . . . . . . . . . . . . 56

Chapter 5 Analyzing OTDR Traces 57Trace display window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

Trace display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Cursors position indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

Defining Calculation Parameters . . . . . . . . . . . . . . . . . . . . . . . . . 60Defining parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Event detection criteria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

Automatic Event Detection and measurements . . . . . . . . . . . . . 61Using Markers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

Markers mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62Adding Markers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Hiding and Displaying Markers . . . . . . . . . . . . . . . . . . . . . . . . . . 63Repositioning a Marker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Deleting a marker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Deleting all the markers and the results . . . . . . . . . . . . . . . . . . . . 64Canceling last actions on markers . . . . . . . . . . . . . . . . . . . . . . . . 64Precise positioning of a marker . . . . . . . . . . . . . . . . . . . . . . . . . . 64Modifying a marker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64Markers group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

Selection of a marker group . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Marker group properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Possible Actions on the marker group . . . . . . . . . . . . . . . . . . . 66To cancel a marker group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67To shift the marker group on the trace . . . . . . . . . . . . . . . . . . . . 67To widen the marker group on the trace . . . . . . . . . . . . . . . . . . 67To copy the marker group to another trace . . . . . . . . . . . . . . . . 67To copy the marker group to another trace with inversion of the markers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67To copy the marker group to a word processing file or a spreadsheet file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68To copy the marker group from a text or a spreadsheet file to a trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

Manual measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69Measuring the Slope of the Trace . . . . . . . . . . . . . . . . . . . . . . . . 69

x FiberCable Manual 7OFSMAN12/05

Page 11: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Table of Contents

Measuring Discontinuity on the Trace . . . . . . . . . . . . . . . . . . . . . 70Measuring Reflectance on the Trace . . . . . . . . . . . . . . . . . . . . . 71Measuring the Optical Return Loss . . . . . . . . . . . . . . . . . . . . . . . 71

To measure the ORL: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Measuring the Contribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Defining a Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

Differences between traces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Both End measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

Measurement Principles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76Execution of a Both End measurement . . . . . . . . . . . . . . . . . . . . 76

Multi-traces analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78Generate a multi-traces analysis . . . . . . . . . . . . . . . . . . . . . . . . . 78

Opening an OEO result from a 6000/8000 Platform . . . . . . . . . . 79Operations onto the OEO files . . . . . . . . . . . . . . . . . . . . . . . . . . 79Save one of the 2 traces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

Results Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80Displaying Results Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80Results table content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

Level of confidence in result table . . . . . . . . . . . . . . . . . . . . . . 82Saving Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Results file contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

To copy the results to a word processing file . . . . . . . . . . . . . . . 84

Chapter 6 Analyzing WDM / OSA traces 85Trace display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86

Trace display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86Cursors position indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

Defining Calculation Parameters . . . . . . . . . . . . . . . . . . . . . . . . 87Calculations carried out on the spectrum . . . . . . . . . . . . . . . . . 89Results Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

Table contents without statistics . . . . . . . . . . . . . . . . . . . . . . . . . 91Choice of channels displayed in the table . . . . . . . . . . . . . . . . . . 92Results sorting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Display of relative results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Link between the trace and the table . . . . . . . . . . . . . . . . . . . . . . 92Successive addressing of channels according to the sort method 93Table contents with statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . 93Saving results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

Exceeding the alarm thresholds . . . . . . . . . . . . . . . . . . . . . . . . . 95Comparing traces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95

Opening an overlay trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95

FiberCable Manual 7OFSMAN12/05 xi

Page 12: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Table of Contents

Trace resulting from difference between traces . . . . . . . . . . . . . . 95

Chapter 7 Analyzing PMD traces 97Trace display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98

Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98Cursor position indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99Cursors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Alarm thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100Results Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

Displaying Results Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102Saving results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102Results file contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

Chapter 8 Analyzing CD traces 105Trace display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106CD Trace selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

Cursors position indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107Defining Calculation Parameters . . . . . . . . . . . . . . . . . . . . . . . . 107Alarm thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108

Wavelength limits (nm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108

Dispersion, Slope and Delay traces . . . . . . . . . . . . . . . . . . . . . . 109OTDR traces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

Marker mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110Automatic positioning of marker . . . . . . . . . . . . . . . . . . . . . . . 110Repositioning a Marker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111Deleting a marker or all the markers . . . . . . . . . . . . . . . . . . . . 111Adding markers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111

Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111CD measurement on a section . . . . . . . . . . . . . . . . . . . . . . . . . 112Bi-directional measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . 113

Results Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113Results Table display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113Table contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114Link between the trace and the table . . . . . . . . . . . . . . . . . . . . . 114Saving results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114Results file contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

xii FiberCable Manual 7OFSMAN12/05

Page 13: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Table of Contents

Chapter 9 Analyzing ATS traces (Spectral Attenuation) 117Trace display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118

Trace display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118Cursors position indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119

Defining calculation parameters . . . . . . . . . . . . . . . . . . . . . . . . 119Results table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

Displaying the results table . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121Table contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121Saving results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121Results file contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122

Chapter 10 Analyzing OFI module results 123Results display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124

Opening fox files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124Results display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124Fiber Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125

Setting the alarm parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . 125Saving results in a txt file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126

Saving results in a txt format . . . . . . . . . . . . . . . . . . . . . . . . . . . 126Saving results in a txt file for Fiber Budget . . . . . . . . . . . . . . . . . 126

Chapter 11 Macros 127Macro principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128Recording a Macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128Executing a Macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129

Chapter 12 Measurement Report 133Measurement Report Methodology . . . . . . . . . . . . . . . . . . . . . 134

Requisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134Measurement Report pProcess . . . . . . . . . . . . . . . . . . . . . . . . . 135

FiberCable Manual 7OFSMAN12/05 xiii

Page 14: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Table of Contents

Selecting traces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136Tooltips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136Selection of files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137Transfer of files in the selection list . . . . . . . . . . . . . . . . . . . . . 137Selection List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138To expand the selection list . . . . . . . . . . . . . . . . . . . . . . . . . . 139Available commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139

Opening the trace(s) for a fiber . . . . . . . . . . . . . . . . . . . . . . . . . 141In the case of a four OTDR trace with middle point . . . . . . . . . 141

Bookmarking the files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143Printing the traces from the Report list . . . . . . . . . . . . . . . . . . . . 143Saving report status information in a txt or xls file . . . . . . . . . . . 144Allocating a reference fiber to the other fibers of the cable . . . . . 146

OTDR reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146PMD or CD reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147

Selecting parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147Cable Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147

Access to Report parameters . . . . . . . . . . . . . . . . . . . . . . . . . 149OTDR parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149

Measurement setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Middle point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152Other . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153Threshold per wavelength . . . . . . . . . . . . . . . . . . . . . . . . . . . 153

PMD parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154Alarm thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154Fiber length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154

CD parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155Thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155Approximation method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 Reference wavelength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155Calculation parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155

Previewing the report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156Previewing bookmarked fibers . . . . . . . . . . . . . . . . . . . . . . . . 156Previewing bookmarked fibers (step by step) . . . . . . . . . . . . . 157

Generating the measurement report . . . . . . . . . . . . . . . . . . . . . 157Generating the report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158Generating the report (step by step) . . . . . . . . . . . . . . . . . . . . 158

Post Processing the measurement report . . . . . . . . . . . . . . . . 158Using the Excel FiberCable Macro . . . . . . . . . . . . . . . . . . . . . . 159

Opening the FiberCable box . . . . . . . . . . . . . . . . . . . . . . . . . 161Report format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161

xiv FiberCable Manual 7OFSMAN12/05

Page 15: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Table of Contents

Report generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162Report printing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162Processing the report in a user defined language . . . . . . . . . . . 162

Appendix A Customer Services 165About our services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166Customer care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166

Technical assistance (business hour) . . . . . . . . . . . . . . . . . . . . 166Warranty information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167

Global services and solutions . . . . . . . . . . . . . . . . . . . . . . . . . . 168

Index 169

FiberCable Manual 7OFSMAN12/05 xv

Page 16: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Table of Contents

xvi FiberCable Manual 7OFSMAN12/05

Page 17: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

About This Guide

Welcome to the FiberCable OFS-200 Software, the standard refer-ence for processing traces acquired using the range of JDSU fiber optic analyzers.

– “About the FiberCable software” page xviii– “About the Platform 6000/8000” page xviii– “Technical assistance” page xviii– “Conventions” page xix

FiberCable Manual 7OFSMAN12/05 xvii

Page 18: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

About This GuideAbout the FiberCable software

About the FiberCable softwareThe FiberCable is the standard reference for PC processing of fiber traces from the JDSU's range of Fiber Optic products in a standard Microsoft® Windows™ environment. It provides trace archiving, com-plex trace analysis, and report generation for fiber installation and maintenance work.

Microsoft® Windows™ allows the user to freely transport his traces to more powerful software applications like Microsoft® Excel, Microsoft® Word using facilities such as screen dump and exporting.

About the Platform 6000/8000The Platform 6000/8000 is called T-Berd 6000/8000 in North America and MTS 6000/8000 in the rest of the world. This manual will always refer to the T-Berd 6000/8000 and MTS 6000/8000 using the term Platform 6000/8000.

Technical assistance If you need assistance or have questions related to the use of this product, call or e-mail JDSU’s Technical Assistance Center for customer support.

Table 1 Technical assistance centers

Region Phone Number

AmericasTelecom Products

866 228 3762 World Wide: 301 353 1550

[email protected]

Europe, Africa, and Mid-East

+49 (0) 7121 86 1345 (Europe)

[email protected]

+33 (0) 1 30 81 50 60 (JDSU France)

[email protected]

xviii FiberCable Manual 7OFSMAN12/05

Page 19: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

About This GuideConventions

During off-hours, you can request assistance by doing one of the fol-lowing:

– leave a voice mail message at the Technical Assistance number in your region;

– e-mail North American Technical Assistance Center, [email protected], or European Technical Assistance Center, [email protected];

– or submit your question using our online Technical Assistance Request form at www.jdsu.com.

ConventionsThis guide uses naming conventions and symbols, as described in the following tables.

Asia and the PacificSoutheast Asia, Aus-tralia, and New Zea-land

+852 2892 0990 (Hong Kong)

+86 10 6833 7477 (Beijing-China)

All others 866 228 3762 [email protected]

Table 1 Technical assistance centers (Suite)

Region Phone Number

Table 2 Typographical conventions

Description Example

User interface actions appear in this typeface.

On the Status bar, click Start.

Buttons or switches that you press on a unit appear in this TYPEFACE.

Press the ON switch.

Code and output messages appear in this typeface.

All results ok

FiberCable Manual 7OFSMAN12/05 xix

Page 20: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

About This GuideConventions

Table 4 Symbol conventions

Text you must type exactly as shown appears in this type-face.

Type: a:\set.exe in the dia-log box

Variables appear in this type-face.

Type the new hostname.

Book references appear in this typeface.

Refer to Newton’s Telecom Dictionary

A vertical bar | means “or”: only one option can appear in a sin-gle command.

platform [a|b|e]

Square brackets [ ] indicate an optional argument.

login [platform name]

Slanted brackets < > group required arguments.

<password>

Table 3 Keyboard and menu conventions

Description Example

A plus sign + indicates simul-taneous keystrokes.

Press Ctrl+s

A comma indicates consecu-tive key strokes.

Press Alt+f,s

A slanted bracket indicates choosing a submenu from menu.

On the menu bar, click Start > Program Files.

Table 2 Typographical conventions

Description Example

This symbol represents a general hazard.

xx FiberCable Manual 7OFSMAN12/05

Page 21: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

About This GuideConventions

This symbol represents a risk of electrical shock.

NOTEThis symbol represents a Note indicating related information or tip.

FiberCable Manual 7OFSMAN12/05 xxi

Page 22: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

About This GuideConventions

xxii FiberCable Manual 7OFSMAN12/05

Page 23: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 1 Installation

1

This chapter describes how to install the FiberCable OFS-200.

The topics discussed in this chapter are as follows:

– “Software requirements” page 2– “Hardware requirements” page 2– “Installing the software on your PC” page 2

FiberCable Manual 7OFSMAN12/05 1

Page 24: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 1 InstallationSoftware requirements

Software requirements– Microsoft® Windows™ version 98 or later.– Microsoft® Excel™ (version 97 or later if the Microsoft® Excel™

Fiber Cable macro is used).– All the files necessary to install the FiberCable software package

on your hard disk are provided on a CD-ROM.

Hardware requirements– An IBM® Pentium 133MHz PC or 100% compatible computer

(Pentium II 233MHz or more recommended).– A Hard disk.– A CD-ROM unit.– 64 MB or more of memory.– A mouse pointing device.– Memory requirements for Microsoft® Excel™ Fiber Cable macro:

64 MB or more of memory (128 MB recommended).– A 800*600 monitor (1152*864 or more recommended).– In addition a printer is recommended, but not required.

Installing the software on your PCYou can install the FiberCable software on your hard drive, modify or upgrade a previous installation, or remove the software from your PC.

First installation 1 Insert the FiberCable Installation CD-ROM in the corresponding player.

2 From the Windows Explorer select the CD-ROM Drive and double click on the JDSU Optical FiberCable Setup.exe icon. The files needed to install the software on your computer are extracted.

3 Select the language you want to use.

2 FiberCable Manual 7OFSMAN12/05

Page 25: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 1 InstallationInstalling the software on your PC

4 The Welcome dialog box prompts you to continue or cancel the installation. Press Next > to continue the installation.

5 A dialog box prompts you to personalize your copy of FiberCable:– In the Name field, type your name, then press the TAB key. – In the Organization field, type the name of your group or

company, and then press the Next > button.

6 You are prompted to choose for the directory to install the software in. The default directory is:C:\Program Files\FiberCable – Press Next > to accept the default directory. – Or to install FiberCable in a different directory, press the

Browse button and enter or select the required directory name and press OK. If you enter a directory name that does not exist, you will be prompted to accept whether or not to create the directory.

7 Select the Setup type to install: – Typical: install the most common options (recommended).– Compact: install the minimum required options– Custom: install the options you choose (for advanced users).Press the Next > button.

8 If the Custom type has been selected, select the components you want to install, then press Next >.

9 You are prompted to choose the Program Folder where you wish to install the application icons. The default directory is: Fiber Cable.– Choose Next > to accept the folder. – Or to install the FiberCable application icons in a different sub-

directory, choose an existing directory from the list displayed or enter a new directory name.

Press Next > to start copying the files or < Previous to go back and change any required parameters.A progress bar and various information messages are displayed.

10 When your first installation of the FiberCable software is finished, you have to restart the computer before using the program. Select either to restart now or later, then press Finish to terminate the installation.

FiberCable Manual 7OFSMAN12/05 3

Page 26: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 1 InstallationInstalling the software on your PC

Modifying or upgrading your

installation

To modify your installation or to install a new software release:

1 Insert the FiberCable Installation CD-ROM in the corresponding player.

2 From the Windows Explorer select the CD-ROM Drive and double click on the Acterna Optical FiberCable Setup.exe icon. The files needed to install the software on your computer are extracted.

3 Select the language used.

4 In the Welcome dialog box:– select Modify if you only want to add missing components.– select Repair if you want to upgrade the current software by a

new one. Press Next > to continue the installation.

5 If the Modify option has been selected, select the components you want to install and clear the components you don’t want. Then press Next >.

Removing the software from

your PC

1 Insert the FiberCable Installation CD-ROM in the corresponding player.

2 From the Windows Explorer select the CD-ROM Drive and double click on the Acterna Optical FiberCable Setup.exe icon. The files needed to install the software on your computer are extracted.

3 Select the language used in the installed software.

4 In the Welcome dialog box select Remove, then press Next >.

5 You are prompted to confirm. Press OK. All the FiberCable appli-cation and all of its components are removed from the PC.

4 FiberCable Manual 7OFSMAN12/05

Page 27: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 2 Generalities

2

This chapter describes the basic functionalities of the FiberCable soft-ware.

Topics discussed in this chapter are as follows:

– “Opening trace files” page 6– “File Operations” page 8– “Printing trace and results” page 9

FiberCable Manual 7OFSMAN12/05 5

Page 28: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 2 GeneralitiesOpening trace files

Opening trace files

Trace file sources To use the FiberCable OFS-200 software you must first have suitable trace files available. These can be files you have previously saved using FiberCable or files you have acquired with the JDSU test plat-forms (with OTDR, WDM, OSA, PMD or CD modules) and transferred to your PC.

FiberCable is also compatible with the OTDR files, .sor type, respect-ing the Bellcore standards 1.0, 1.1 ans 2.0.

Opening a file To open a file use the following steps:

1 Press the button or select the menu File > Open.The Open dialog box is displayed.

2 Select the drive and directory you require using the standard windows navigation options.

3 Select the type of file you want to open (OTDR, DWDM, etc.) and its format (*.tfw, *.wdm, *.wtk, *.sor, etc.).The file selection menu shows in the upper part the list of files of the directory with the type and format you have selected, and in the lower part the general information for each trace:

Other specific information is displayed depending on the type of measurement.

File The file name.Date The date and time the acquisition was made.

Device The type of product used for the measurement

Cable The Cable Identification (ID)

Fiber The Fiber Identification (ID)

6 FiberCable Manual 7OFSMAN12/05

Page 29: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 2 GeneralitiesOpening trace files

4 To simplify the selection of a trace from a long list of traces, you can specify the order in which the traces are displayed. To do this left click on the column heading name to sort the trace file using the criteria you have selected. For example, clicking on the Date column heading name will sort the trace files by date.

5 To open the trace file, either Left-Click on the trace you require from the list of traces menu and then left-click on the Open button, or double left-click on the required trace.

Opening several files in the same window

You can also open several OTDR or WDM/OSA files at the same time. To do this select the required files and left-click on the Open or Open in the same window button. According to the button used, the traces will be opened in different windows or in the same window. You can then use the Display/Multi-trace commands to add or remove a trace in the window: see "Displaying Multi traces (OTDR / WDM -OSA)" page -54.

Files conversion With the FiberCable OFS-200 software, you can:

– directly open an OTDR trace, to the «WTK» format (from a MTSe

Série 5000 series or MTS 5100 OTDR) and save it to the «SOR» format (format used with the Platform 6000/8000 and with FiberCable version 4.0).

– convert the TFW files (previous FiberTrace format for OTDR) into SOR or WTK files.

– automatically convert several files at the same time. You will have to use the Import and Export functions in the File menu.

Converting several «WTK» files into

«SOR»

To convert several «WTK» or «SOR» traces, use the function File/Import/JDSU MTS 5000 files... A new window opens:

1 Find, in the Source field, the trace(s) to convert.

2 Select the traces to be converted.

3 Choose the directory where the traces will be stored (click on Create directory if necessary)

4 Click on Import for a partial selection or on Import All for a whole selection.

FiberCable Manual 7OFSMAN12/05 7

Page 30: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 2 GeneralitiesFile Operations

5 Click on Close to close the dialog box. The converted files are available in the destination directory.

Converting several «SOR» or «TFW» files

to the «WTK» format

To convert several «SOR» or «TFW» traces into «WTK» format, use the function File/Export/JDSU MTS 5000 files... A new window opens:

1 Find, in the Source field, the trace(s) to convert.

2 Select the traces to be converted.

3 Choose the directory where the traces will be stored (click on Create directory if necessary)

4 Click on Export.

Click on Close to close the dialog box. The converted files are avail-able in the destination directory chosen.

File Operations

To save your work When you save your work, you can change its name and its location. When you change the name of a file or its location you create a copy of the file.

1 Choose Save as... from the File menu.

2 Change the name of the file, open a different directory to hold the file in, or do both.

3 If necessary, change the type of file to save it in another format.

4 Click Save.

Delete Trace(s) You can delete Trace(s).

1 Choose Delete... from the File menu.

2 Select the source drive and directory where the trace you want to delete is located.

8 FiberCable Manual 7OFSMAN12/05

Page 31: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 2 GeneralitiesPrinting trace and results

3 Select the trace(s) you want to delete.

4 Click Delete.

5 Click Yes in the confirmation dialog box to delete the trace and its associated file.

Printing trace and resultsFiberCable is preset to print a copy of the trace and, if it exists, of the results table on a pre-selected printer by simply clicking the but-ton (or using the File > Print menu).

But before you print a trace for the first time you have to:

– check the printer selection and choose the printer options you want to use.

– select the page setup and enter the required parameters.

To select your printer and

printing optins

Before you print a trace for the first time, you may want to check the printer selection and choose the printer options you want to use.

1 Choose Print Setup from the File menu.

2 Choose the printer.

3 Choose a paper source and paper size.

NOTEIf a mosaic page layout is used (for example, more than one page on an A4 format), then all mosaic cases must be filled, otherwise there is no printing (see “Mosaic page layout” page 13).

NOTEYou can choose to print the trace on paper or in pdf format; for this fomat a pdf writer software is mandatory (Adobe Acrobat / Cuteprin-ter / PDFCreator...).

FiberCable Manual 7OFSMAN12/05 9

Page 32: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 2 GeneralitiesPrinting trace and results

4 Make sure you have correctly selected all the options you want to use: you can print a scaled image of your document, print in portrait or landscape orientation, etc.

5 Click OK.

To Setup the page To make easier identification of printed traces and results you can:

– add specific information to the headers and footers of your print-outs.

– apply margins around the pages.– add a logo.– choose the arrangement of pages.– request a print of a trace, table, comments and uncertainties, and

specify whether the results table is to be printed on the first page.

1 Choose Page Setup from the File menu. The Page Setup dialog box is displayed.

Fig. 1 Page Setup dialog box

10 FiberCable Manual 7OFSMAN12/05

Page 33: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 2 GeneralitiesPrinting trace and results

2 Under the Page tab:– Enter the text and any codes you require in the header and footer

of the page(s).

Pressing the ? button displays all the codes you can use.

The following codes are available:

Example: the following entry in the Header field: Trace &T will give on each page header: Trace JDSU_01 if the title of the trace is JDSU_01.

– Enter the size of the margins you require for the left, top, right and bottom of the page.

– Enter the folder path of the file containing the logo and the file name (in .bmp or .WMF format)

– Enter the company name: they will be printed at the top right of the page.

3 Under the Content tab, you can either use the default settings by clicking on the Default button, or change the printer options by checking the associated boxes to your own requirements:

&P Inserts the page number (by default in the footer).

&T Inserts the title of the trace (by default in the header)

&& Allows you to insert the & character.

Logo Logo and company name selected in the Page setup windows will be printed (see Figure 1 on page 10).

Configuration Title, Operator, Cable, Fiber, Origin, End, and parameters depending on the type of trace (OTDR, WDM, etc.) will be printed.

Comments Comments entered when acquiring the trace will be printed.

FiberCable Manual 7OFSMAN12/05 11

Page 34: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 2 GeneralitiesPrinting trace and results

Mosaic setup Choose the Mosaic presentation (number of pages to be printed on a sheet):

Multi-traces printout In this part, you can choose to print all traces on the same page or print each indivudual trace on a separate page with its associated results table.

Job Information relative to the job (cable manu-facturer, cable type, fiber type, etc.) will be printed. This option is not available when a mosaic layout is selected.

Trace the trace and its parameters will be printed

Results summary the Results table will be printed (on the second page if the next case is not notched)

Results summary on first page

the result table will be printed on the first page with the parameters (and with the trace if selected).

No normal page layout of 1 page per sheet

1 x 2 2 columns = 2 pages per sheet

2 x 1 2 columns per page

2 x 2 2 lines, 2 columns = 4 pages per sheet

Others a dialog box allows for the entry of the required number of lines and columns per sheet

Multiple-traces All the traces will be printed on the same page

Single traces Each trace opened in the same window will be printed on a separate page, with its associ-ated results table.

NOTEUsing the Mosaic setup 2 x1 and the Single traces parameter, you can directly and easily printout a bi-directional analysis with sepa-rate traces and results in a 2 columns format.

12 FiberCable Manual 7OFSMAN12/05

Page 35: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 2 GeneralitiesPrinting trace and results

To Preview the printing

Before printing the trace you can preview it to see what it will look like when it is printed with the options you have selected.

1 Choose Print Preview from the File menu or click on the . icon.

2 Use the command buttons to preview what will be printed: Previous, Next: to scroll the pages, One Page, Two Pages: to have one or two pages simultaneously displayed on the screen.

3 Click Close to quit the preview display or Print to start the printing.

To Print the Trace – Click on (or choose the Print option in the File menu). – Enter the number of required copies.– If needed, click on Properties, to make any changes to the printer

configuration.– Click on the Print button.

If a normal page layout (Mosaic: No) has been selected, that is to say one page per sheet, then the pages are printed.

Mosaic page layout If a Mosaic page layout (N squares) has been defined (refer to the pre-vious page), then the N squares must be filled, otherwise the pages are not printed.

For example, for a mosaic 2 x 2, if only three pages are filled, when a print is submitted, the printer waits until the empty square is filled.

NoteThe job parameters cannot be printed if the mosaic setup is selected.

NOTEThe alarms thresholds selected in the menu Display > Alarms... will be printed in the printout header, wether the file is printed on paper or in pdf format.

FiberCable Manual 7OFSMAN12/05 13

Page 36: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 2 GeneralitiesPrinting trace and results

d

NOTETo force a printout when all the mosaic squares have not been filled, select Eject page from the File menu. This Eject page option is fol-lowed by the number of occupied squares from the selected mosaic presentation (in our example: 3/4).

14 FiberCable Manual 7OFSMAN12/05

Page 37: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTS

3

From a PC, FiberCable enables you to remote control the functions OTDR, WDM of the MTS (with the corresponding modules).

Topics discussed in this chapter are as follows:

– “Remote Control menus” page 16– “Configuration of a MTS <-> PC link” page 16– “Connection of the MTS to the PC” page 17– “Transfer of files MTS <-> PC” page 24– “Remote Control of a measurement on the MTS” page 26– “Storing traces” page 29

FiberCable Manual 7OFSMAN12/05 15

Page 38: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSRemote Control menus

Remote Control menusThe Remote menu of FiberCable allows to control the functions (OTDR, OSA, etc.) of a MTS:

– configuring the PC-MTS link,– requesting the connection or disconnection – transferring the results files from MTS to PC or from PC to MTS.– configuring the MTS module (OTDR, OSA, etc.),– starting a measurement– storing the results of the measurement.

Configuration of a MTS <-> PC link1 In the Remote menu, select the Connect... option. A dialog box is

displayed.

2 Choose the type of connection between the PC and the MTS with the associated parameters:

– Ethernet: IP Address.– PPP: Select the driver that is configured in Windows (exclusively

used with the MTS 5x)– RS232: Port COM1, COM2, ... and transmission rate (exclusively

used with the MTS 5x).

3 Click the OK button.

4 Choose the Remote > Connect menu option to establish a connec-tion.

When a message is displayed indicating that a connection has been made, click OK.

16 FiberCable Manual 7OFSMAN12/05

Page 39: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSConnection of the MTS to the PC

Connection of the MTS to the PC

Connection via the Ethernet

interface

The connection of the Platform 6000/8000 to the PC via Ethernet is done automatically.

The MTSe Série 5000 can be remotely controlled via the RS 232-C (type DCE) interface of the controller.

Link between the MTS 5x and the PC

The link with the PC may be direct or via a network:

1 To establish a direct link between the Ethernet ports of the MTS 5x and of the PC, use the Ethernet crossed cable supplied with the Ethernet option of the MTS 5x.

2 To establish a link via the network, ask the network administrator for an IP address and connect the MTS 5x on a hub by using a direct cable supplied by the administrator (and not the crossed cable provided with the MTS 5x Ethernet option).

Configuration of MTS 5x– Start the MTS 5x and press the key Config. System.– Select the interface E/S: FTP/Eth using the key pad. – Configure the Ethernet interface: IP address, IP mask, IP bridge.

NOTEThe IP address is in the following form: xxx.xxx.xxx.xxx (4 numbers separated by dots) If one of the numbers has only one or two digits, enter only this (or these) digit(s). Do not add a zero, otherwise the link will not be established.

NOTETo check that the connection has been made correctly, without using the software WS-FTP Pro, click on Start, then on Execute..., and choose: ping followed by the IP address of the MTS 5x.

FiberCable Manual 7OFSMAN12/05 17

Page 40: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSConnection of the MTS to the PC

Connection via the RS232

interface

Connect the serial remote controller to the 9 pin serial connector (RS232 DTE) of the MTS 5x.

Selection of the MTS 5x transmission parameters

In the SYSTEM / RS232 menu, if necessary modify the following config-uration parameters:

1 Connect the modem to the MTS 5x via the RS232 connector.

2 On the MTS 5x, in the System set-up > Remote Access menu, select the option TCP/PPP.

3 On the MTS 5x, press on the Init Modem key: the modem connected to the MTS 5x is initialized. You are ready to transfer data.

Local connection via ppp

You can, using the PPP protocol, connect directly the MTS 5x (RS 232 port)1 and the PC via a cable seen as a modem.

NOTEThis connection is only available with the MTS 5x.

As PCs are usually configured as DTE, an adaptor (DTE to DCE) may be needed to connect the PC to the MTS 5x.

BAUD RATE 115200

CHAR. LENGTH 8 bits

STOP BIT 1

PARITY Without

TERMINATOR CR

PROTOCOL RTS/CTS

NOTEThe transmission rate must be the same for both MTS 5x and PC.

1. see "Connection via the RS232 interface" on page -18

18 FiberCable Manual 7OFSMAN12/05

Page 41: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSConnection of the MTS to the PC

Then you have to:

1 install this fictive modem on the PC.

2 configure the link on the PC.

NOTELocal connexion via ppp can be done exclusively with a MTS 5x.

NOTEWhen the MTS 5x is connected to the PC using the PPP protocol, if the connection is unintentionally interrupted, the MTS 5x considers that it is still connected for about 3 minutes and refuses all attempt to connect it in the meantime.

If the MTS 5x is accessible, you can switch it off/on to avoid this delay before restoring the connection.

NOTEThe following procedures are given for information only: they can be slightly different according to the PC configuration.

FiberCable Manual 7OFSMAN12/05 19

Page 42: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSConnection of the MTS to the PC

Connexion via existing ppp

In the Remote menu, click on Connection and select PPP.

Select the required connection..

Click on Connect... to start the connection of the MTS 5x to the PC.

When a message is displayed, indicating that a connection is estab-lished, click OK.

The MTS 5x is connected to the PC.

Create a new connection

In the Remote menu, click on Connection > PPP.

Fig. 2 Driver configuration

Select PPP

NOTETo edit or modify the connection parameters, click on Modify PPP in the Driver Configuration dialog box. Then, click on Properties in the Configuration PPP dialog box.

Fig. 3 Connecting...

20 FiberCable Manual 7OFSMAN12/05

Page 43: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSConnection of the MTS to the PC

Click on Modify PPP > Add to create a new connection.

With an existing modem

In the Add MTS connection dialog box, enter a connection name and select the modem in the list.

Once the modem is selected and the name is entered, click Add but-ton.

The Configuration PPP dialog box reappears, with the name of the connection, the type of modem and the corresponding number.

Click on Close button to go back to the Driver Configuration dialog box.

Click on Connect to start the MTS 5x connection to the PC.

Fig. 4 Configuration PPP

Fig. 5 Modem selection

Fig. 6 Connecting...

Add a connection

Connection name Modem

selection

FiberCable Manual 7OFSMAN12/05 21

Page 44: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSConnection of the MTS to the PC

When a message is displayed, indicating that a connection has been enabled, click OK.

Add a new null. modem

In the Add MTS connection dialog box, click Add MTS5000 null modem....

,

Select a communication port in the list and click OK.

The modem is loading and a dialog box opens:

Click on the Continue Anyway button to finish the installation.

Fig. 7 Install a new port

Fig. 8 Digital signature

Add MTS5000 null modem...

22 FiberCable Manual 7OFSMAN12/05

Page 45: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSConnection of the MTS to the PC

After less than 1 minute, the Add MTS connection dialog box is dis-played with the name of the modem (Acterna Mts)..

Enter the connection name and click on Add to validate.

The Configuration PPP dialog box reappears, with the connection name, the modem type and the corresponding number.

Click on Close to go back to the Driver Configuration dialog box.

Click on Connect to start the MTS 5x connection to the PC.

The Connecting... dialog box opens (Figure 3)

When a message is displayed, indicating that a connection has been made, click OK.

Disconnecting the MTS from the PC

Once the files are transferred (see "Transfer of files MTS <-> PC" page 24):

Select Disconnect in the Remote menu.

Fig. 9 Connection name

Connection name Name of the

modem

FiberCable Manual 7OFSMAN12/05 23

Page 46: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSTransfer of files MTS <-> PC

Transfer of files MTS <-> PCIn the Remote menu, select the File Transfer ... option. The File Transfer dialog box is displayed. In this box :

– the left-hand side windows are relative to the local system (PC).– the right-hand windows are relative to the remote system (MTS).

File transfer from the PC to a remote MTS

1 On the local system (PC), use the drop down menu to access the folder where the file(s) are stored to be transferred. The contents of the folder is displayed in the bottom left-hand side window.

2 Select either the folder or the required file(s) in the folder to be transferred.

Fig. 10 Transfer of files

PC side MTS side Enter / Selct folders

24 FiberCable Manual 7OFSMAN12/05

Page 47: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSTransfer of files MTS <-> PC

3 Click the button to transfer the file(s) to the remote system.

File transfer from the MTS to the PC

Searching for the files to transfer to the PC:

With a Platform 6000/8000, manually enter the user directory acterna\user\ and choose the support where the files are stored:

– harddisk: MTS harddisk– cflash: MTS mother board– disk: MTS internal memory

With the MTS 5x, directory are displayed automatically.

1 Select either the whole directory or the required file(s) in the direc-tory.

2 Click the button to transfer the file(s) to the PC.

Possible actions on the selected files on

PC or MTS

Four buttons enable the following actions to be executed on the selected files on the PC and the MTS:

Refresh

Updates the current display

Delete files

Deletes selected files without requesting any confirmation.

Create a directory

Creates a folder in which a name must first be entered.

NOTERespect the typography for the directory manual input.

NOTEIt is not possible to select more than one directory, however you can select and transfer several files at one time.

FiberCable Manual 7OFSMAN12/05 25

Page 48: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSRemote Control of a measurement on the MTS

Delete directory

Deletes the selected folder. A confirmation is requested before execut-ing the deletion.

Leaving the transfer menu

Click the Exit button to leave the transfer menu.

Remote Control of a measurement on the MTSAccording to the modules included in the MTS (OTDR, WDM, etc.), the user will have different Remote Control possibilities.

Acquisition of an OTDR trace

1 In the Remote menu, select Measurement > Setup OTDR. The following dialog box is displayed:

The MTS type, serial number and software version are indicated in the Device field.

2 Select the OTDR module of the MTS (if two modules are present).

Fig. 11 OTDR configuration module

26 FiberCable Manual 7OFSMAN12/05

Page 49: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSRemote Control of a measurement on the MTS

3 Choose the measurement parameters: wavelength, pulse width, range, acquisition time, resolution. Click Auto to have an auto-matic selection of the resolution.

4 Click the OK button. The Trace information dialog box is displayed:

5 Enter the measurement information: – Title – Operator name– Cable identification– Fiber number. – Automatic fiber number increment for each acquisition or not.– Identification of the origin and of the extremity– Way: Origin -> Extremity or Origin <- Extremity.

6 Click the OK button to configure the OTDR module.

7 To start the measurement, select the Measurement > Start option from Remote menu.

The trace is then transferred to the PC.

Acquisition of an optical spectrum

1 In the Remote menu, select Measurement > Setup OSA. The following dialog box is displayed:

Fig. 12 WDM Configuration module

FiberCable Manual 7OFSMAN12/05 27

Page 50: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSRemote Control of a measurement on the MTS

The MTS type, serial number and software version are indicated in the Device field.

2 Select the WDM module of the MTS in which the measurement is to be carried out on (if two modules are present).

3 Choose the measurement conditions: – Number of required sweep to establish the trace (1 to 100),– High sensitivity:

No = power +15 to - 65 dBm Yes = power - 25 to - 75 dBm.

– Filter resolution: Max (<0,1 nm) or 0,1 / 0,2 / 0,3 / 0,4 / 0,5 nm.– Signal thresholds: Auto or Manual (-79.9 to + 20 dBm).

4 Click the OK button. The Trace information dialog box is displayed:

5 Enter the measurement information: – Title– Operator– Cable identification– Fiber number. – Automatic fiber number incrementation for each measurement, or

not– Identification of the origin, the extremity and the test point.

6 Click the OK button to configure the OSA module.

7 To start the measurement, select the Measurement > Start option from the Remote menu.The trace is then transferred to the PC.

The trace is then displayed on the screen of the PC and can be even-tually stored (see "Storing traces" page 29) or analysed.

28 FiberCable Manual 7OFSMAN12/05

Page 51: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSStoring traces

Storing tracesThe storing of the traces can be carried out in two ways:

– manually using the menu File > Save As... – automatically after the acquisition.

To define the required save type, from the Remote menu, choose the Measurement > Storage option.

The Saving acquisitions dialog box is displayed.

1 Select either Yes or No from the Automatic storage option.

2 Indicate which directory is to be used to store the trace.

3 Select the file naming type: Manual, Semi-automatic or Automatic. Refer to "Naming files" page 30 for further explanation about these options.

Fig. 13 Automatic Saving option of an OTDR trace

FiberCable Manual 7OFSMAN12/05 29

Page 52: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSStoring traces

4 Choose the file format from the below supported list (depending on the PC’s configuration). See next sections.

5 Click OK.

Format for OTDR traces

Format for optical spectrum

Naming files The user can choose from the three different filename types:

Automatic The factory-defined code is indicated in the Name Coding window and the character definitions are given in the Key Characters windows.

Semi-automatic The name of the file is automatically created when it is being stored using the code that the user must enter in the Name Coding window. The character definitions are recalled in the Key Characters windows. The filename can contain fixed UPPERCASE characters, which is dif-ferent from the code that is always in lowercase.

Manual A filename can be entered in the Name Coding window: - any uppercase characters can be used - lowercase characters must correspond with the code.

NOTEWith automatic storage, the filename type must either be semi-auto-matic or automatic.

tfw format of a trace created from FiberCable.

wtk JDSU format, corresponding to a compressed Bellcore format.

sor format in convention with the Bellcore GR-196 stan-dards

wdm JDSU format

txt ASCII format for a transfer to a spreadsheet or word processing program.

30 FiberCable Manual 7OFSMAN12/05

Page 53: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSStoring traces

If a filename or a code has been entered, or left in the Name Coding window, when being stored by Save As..., this filename will be pro-posed to the user who could either accept or modify it.

For further details about automatic and semi-automatic filename types, refer to the File management chapter of the MTS 5x user man-ual.

FiberCable Manual 7OFSMAN12/05 31

Page 54: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 3 Remote control of the MTSStoring traces

32 FiberCable Manual 7OFSMAN12/05

Page 55: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying Traces

4

This chapter describes the main traces displaying functions.

Topics discussed in this chapter are as follows:

– "Traces display window" page 34– "Actions on traces" page 41– "Display Zoom Functions" page 41– "Cursors" page 47– "Setting Display Preferences" page 50– "Displaying open trace files" page 53– "To copy the trace to a word processing file" page 56

FiberCable Manual 7OFSMAN12/05 33

Page 56: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesTraces display window

Traces display windowThe traces display window provides the commands and functions required to operate trace analysis.

The window contains the following items:

– The Menu bar (different according to the type of trace).– The Tool bar (different according to the type of trace).– The Trace Parameters window.– The display of the active trace file or of all open trace files

depending on the window display mode.– The Status Bar (different according to the type of trace).– The table resultas (if selected)– The table markers (only for OTDR traces, if selected)– The small trace– The Alarms results (if the table results is displayed)

Fig. 14 Traces display window

Small traceCursors position

Status Bar Trace Alarms table

Tool barMenu Bar

Parameters Results table

34 FiberCable Manual 7OFSMAN12/05

Page 57: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesTraces display window

The menu and tool bars

The menu bar generally have the same commands as the tool bar, but not necesseraly. Exclusively the most used functions of the menu bar are available on the tool bar.

The trace The open trace(s) is / are open in a window. According to the trace type, several actions can be done: zoom, shift the trace, display a grid, add markers / events, set cursors etc. (See "Actions on traces" page 41)

Trace parameters Some trace parameters can be modified or added in order to change any identification data that was included during the acquisition.

To edit the trace information select Edit trace information from the File menu or double click on the Trace information window.

All the information about the trace is displayed in the Trace information dialog box under the different tabs, but you can only edit the informa-tion displayed on a white background.

The following information and parameters are given for all the types of trace

NOTEThe icons which can be activated are colored whereas those you cannot activate are dispayed in grey.

The tool and menu bars are different according to the type of trace open.

Tab Parameter DescriptionINFORMATION File File name

Technic Operator name.Comment Comment about the acqui-

sition (up to 90 characters).ACQUISITION Date, Hour Date and time of trace

acquisition.

FiberCable Manual 7OFSMAN12/05 35

Page 58: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesTraces display window

* Not available for fox results

Customize the job parameters

The job information are, by default: Cable Manufacturer / Cable Type / Fiber manufacturer / Fiber Type / Contractor / Project Manager / Jointing.

However, you can modify the labels set by default:

1 notch the case User defined labels.The labels are displayed on a white background

2 Modify the labels name and enter the specific parameter for each one.

All the new labels will be saved and re-used for each trace.

Device Device type and serial num-ber

Module Type and serial number of the module used for the measurement.

CABLE Cable Origin Cable origin identificationFiber Origin * Fiber origin identificationColor Origin * Color origin fiberCable End Cable end identificationFiber End * Fiber end identification.Color End * Color end identificationOrigin Name of the origin location;

for example the name of the town or geographic location

Extremity Name of the end location; for example the name of the town or geographic location

JOB Allows you to enter information relative to the cable and fibers and the project in which they are used.

36 FiberCable Manual 7OFSMAN12/05

Page 59: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesTraces display window

There are also some specific parameters for each type of trace.

OTDR parameters The specific parameters for OTDR traces are:

Tab Parameter DescriptionACQUISITION Lambda (nm) Wavelength in nm of the

MTSPulse (us) Pulse width of the OTDR

laser in microseconds.Acq. Time Time taken to make the

averages.Range Distance range.Resolution Distance between 2 acqui-

sition points.Index Index of refraction of the

fiber.CABLE Way Direction of the measure-

ment (Origin -> End or End -> Origin).

FiberCable Manual 7OFSMAN12/05 37

Page 60: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesTraces display window

WDM / OSA parameters

The specific parameters for WDM / OSA traces are:

PMD parameters The specific parameters for PMD traces are:

Tab Parameter DescriptionACQUISITION Wavelength

(nm)Wavelength (or frequency) range of the spectrum

Number of acqui-sitions

Number of acquisitons for statistical calculation (from 2 to 100).

Resolution Max. resolution used.High sensivity Yes / NoAverage Number of measurementsSNR method Method used for the signal/

noise ratioDistance S<->N (Ghz)

Distance between the 2 modules

Noise acquisition (nm)

Noise acquisition level

Coupler compen-sation

Attenuation due to the access point.

CABLE Test point Identifies the point of where the analyzer is positioned.

Tab Parameter DescriptionACQUISITION Wavelength

(nm)Wavelength (or frequency) range of the spectrum

Number of acqui-sitions

Number of acquisitons for statistical calculation (from 2 to 100).

Average Number of measurementsFiber length Length of the fiber (to calcu-

late the PMD coefficient).

38 FiberCable Manual 7OFSMAN12/05

Page 61: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesTraces display window

CD parameters The specific parameters for CD traces are:

Coupling Strong (for classical, single-mode fibers)Weak (for polarization-maintained fibers and com-ponents)

CABLE Test point Identifies the point of where the analyzer is positioned.

UNDER THE DISPLAYED PARAMETERS

Methods Method used for statistics calculation (FTT / DRIFT)

Tab Parameter DescriptionACQUISITION Length Length of the fiber or of the

section under testIndex Index of refraction of the fiber.

CABLE Way Direction of the measure-ment (Origin -> End or End -> Origin).

CALCULA-TION

Methods Formula used for delay fitting in order to generate disper-sion and slope measure-ments: quadratic, 3T Sellmeier, 5T Sellmeier.

Wavelength ref. Wavelength taken as refer-ence for delay calculation: other wavelength delays are subtracted from this reference delay.

Fiber type Standard / Special- Used to measure hybrid fiber links configuration such as Disper-sion compensating fiber.

FiberCable Manual 7OFSMAN12/05 39

Page 62: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesTraces display window

ATS parameters The specific parameters for ATS traces are:

FOX parameters

Specfic information Extremities are different

If the option «Extremities different» is selected, in the Cable tab, you can specify a different name and color code for cable and fiber, at each end.

Launch cable (OTDR)

Click on the corresponding radio button to show wether there are no or 1 to 3 launch cables at the front end, the middle (if there is a loop) or at the far end of the cable.

Moving between events (OTDR)

To move quickly from one event to another on the active trace, use the Next Event or Previous event command in the Calculation menu (or select the or button). The next or previous event is centered in the screen.

Tab Parameter DescriptionACQUISITION Wavelength Wavelength range of the

spectrumAveraging Number of measurementsFiber length Length of the fiber or of the

section under test.

Tab Parameter DescriptionACQUISITION Index of refrac-

tionEnter a value for the index of refraction.

NOTEThe «Extremities are different» parameter is exclusively available with traces acquired with a 6000/8000 Platform.

40 FiberCable Manual 7OFSMAN12/05

Page 63: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesActions on traces

Actions on traces

Grid (OTDR / WDM)

The display window of the trace may contain a grid to facilitate the con-trol of the position of the markers.

To display a grid on an OTDR trace, click on or in the Dis-play>Grid menu. To remove the grid, click once again onto the icon or unselect Grid in the Display menu.

One of the following grid types can be selected from the Display > Grid menu for the WDM / OSA traces.

– Conventional grid: the space interval is indicated in the top right corner of the window. It varies according to the zoom level.

– ITU grid: it uses the ITU-T G.692 channel plan channel spacings available: 50, 100 or 200 GHz.

– Grid defined by the user to correspond exactly to the channels. Enter the position of the first vertical line (wavelength of the first channel), the spacing between channels and the number of chan-nels.

Display Zoom Functions

The zoom functions are used to widen or reduce the trace diplay. With an OTDR file, you can also set a predefined zoom.

Zoom-in To zoom-in on the trace display:

1 Press the button or select Zoom from the Display menu.The cursor changes to a when you move it into the trace display window.

Once the cursor is displayed, you can:

NOTEFor the CD traces, the zoom functions are exclusively available with the OTDR mode.

+

FiberCable Manual 7OFSMAN12/05 41

Page 64: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesActions on traces

– Select a section: the selected part will be automatically enlarged.– Click as many time as necessary: the trace will be zoomed in with

constant step. The reference point is the clic location of the mouse.

– Set the cursor on the trace and use the mouse roll forward to enlarge the display.

Zoom out To zoom out on the trace section:

– Click as many times as necessary on the icon .

or

– Set the cursor on the trace and use the mouse roll backward.

Vertical or horizontal zoom

To make a vertical or horizontal zoom:

1 Click on

2 Set the cursor onto the section to enlarge.

3 Press and hold down the Shift key (for a vertical zoom) or the Ctrl key (for an horizontal zoom).

4 Use the mouse roll forward to zoom-in, and backward to zoom-out.

Reset the zoom To reset the display to show the complete trace: press the button or select Zoom reset from the Display menu.

Predefined zoom (OTDR)

With OTDR files, it is possible to predefine zoom levels which will be saved.

+

+

NOTEYou cannot select a section to be zoomed out. You have to select the Zoom out function as many times as necessary, the Zoom in icon being automatically the icon by default.

+

42 FiberCable Manual 7OFSMAN12/05

Page 65: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesActions on traces

To define these levels, modify them, rename or delete them, select Predefined Zoom from the Display menu.

You can define several zooms. To apply them, use the same option in the menu or use the icons . These icons are used to apply directly the previous and next predefined zoom.

Saving predefined zoom levels to a text file

It is possible to create a text file containing different predefined zooms and to import them into a trace.

1 To export the predefined zoom levels to a text file:– click on the Export key.– in the Save As... window, enter the filename and its location, then

click on Save.

2 To import predefined zoom levels in a trace:– click on the Import key.– select the file– click on the Open key.

Using the maximum display

area

The trace window, by default, does not occupy all of the display. The left-hand side is left free for the trace parameters. If you want to use all of the display for the trace, press the icon Trace only (different accord-ing to the type of trace) or select Trace only in the Display menu.

Icon Trace only for OTDR traces.

Icon Trace only for WDM traces

Icon Trace only for PMD traces

Icon Trace only for CD traces

Icon Trace only for ATS traces

To return to the display of parameters, press again the icon or unselect Trace only in the Display menu.

FiberCable Manual 7OFSMAN12/05 43

Page 66: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesActions on traces

Displaying the Results / Alarms

table

To show or hide the table, click on the icon or select Table results in the Display menu.

To move the Results / Alarms table, click on the window upper part and move the table where you want before releasing the mouse button.

To set the table to the pop-up mode or contrary, double click in the win-dow upper part.

Trace Shift (OTDR / WDM-OSA)

Once you are in multi-traces mode (see "Displaying Multi traces (OTDR / WDM -OSA)" page 54) you can shift traces horizontally and vertically from the active trace to make measurements on the active trace more easily.

OTDR Trace shift Different procedures allow you to shift one or several traces according to a fix one.

– If more than two traces are displayed only the manual procedure and the one using the mouse are possible.

– If only two traces are displayed, directions are available in the tool bar to automatically shift the two traces horizontally, vertically or in both directions.

Manual procedure– Select Shift > Shift … of the Display menu.

– Choose the required X and Y shift for each trace, from the displayed dialog box.

– Click on Apply to see the chosen shift without closing the dialog box or click on OK to apply the shift and close the dialog box.

Fig. 15 Manual shift

44 FiberCable Manual 7OFSMAN12/05

Page 67: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesActions on traces

Shift using the mouse– Select the reference trace (fixed), with the radio button (see

"Displaying Multi traces (OTDR / WDM -OSA)" page 54)– Press and hold down the Ctrl key– Set the cursor on the trace– Use the mouse roll forward to shift the trace to the right, and back-

ward to shift the trace to the left.

Horizontal auto shift

1 Position the cursor A at the location on the active trace where you want the overlay trace to be horizontally shifted.

2 Position the cursor B at the point on the overlay trace that you want to move to the position indicated by the cursor A.

3 Press the button or, in the Display menu select Shift > Shift X (B to A), to shift the reference trace to the required position.

4 To reposition the overlay trace to its original horizontal position, press the same button or select in the Display menu: Shift > Shift X (B to A), without positioning any cursors.

Vertical auto Shift

1 Position the cursor A at the position on the active trace where you want the overlay trace to be vertically shifted.

2 Press the button or select, in the Display menu: Shift > Shift Y (along A) to shift the overlay trace to the required position.

3 To reposition the overlay trace to its original vertical position, press the same button or select, in the Display menu: Shift > Shift Y (along A), without positioning any cursors.

Horizontal then vertical auto shift

1 Position the cursor A at the position on the active trace where you want the overlay trace to be shifted.

2 Position the cursor B at the point on the trace where you want to move the position indicated by the cursor A.

3 Press the button or select in the Display menu: Shift > Shift X then Y (along A), to shift the reference trace to the required posi-tion.

FiberCable Manual 7OFSMAN12/05 45

Page 68: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesActions on traces

4 To reposition the overlay trace to its original horizontal position, press the same button or select, in the Display menu: Shift > Shift X then Y (along A) without positioning any reference cursors.

Vertical shift for WDM / OSA traces

When one or more WDM / OSA traces are displayed, it is possible to shift them vertically.

– Select in the Display menu the option Shift Y...:

– Choose the shift interval for the trace(s) to be shifted.– Click Apply to check the interval without closing the dialog box,

and make any modifications if necessary.– Click OK to close the dialog box.

NOTEIn Zoom mode, it is impossible to shift the trace.

Fig. 16 Traces shift

46 FiberCable Manual 7OFSMAN12/05

Page 69: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesCursors

Cursors

Mouse pointer If you move the mouse pointer in the trace display window, the pointer will be represented by:

– A small circle on the trace– A small triangle on the X and Y axis.

This representation is useful to show the precise coordinates of the trace point, corresponding to the mouse position.

Fig. 17 Symbols used to check the mouse position according to the trace

Cursors A and B You can position two reference cursors (A and B) and then have delta results between the reference cursors. These cursors are dotted ver-tical lines.

1

2

3

FiberCable Manual 7OFSMAN12/05 47

Page 70: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesCursors

The cursor position indicator shows the distance and attenuation from the start of the fiber to the point that the cursor intersects with the trace. It also indicates when the cursor is in the zone preceeding an event, the number and characteristics of this event.

Positioning A and B cursors

To accurately position a cursor it is often easier to first zoom-in on the display (refer to “Zoom-in” page 41).

To move a cursor, select it and drag it with the mouse, or click on the position you want.

Cursor selection To make the cursor selection easier, use the option Cursor Mode in the Display menu.

– Cursor «Auto»: the active cursor is the closest one of the current cursor. Directly click on the display window allow you to immedi-ately move the active cursor. This option allows you to move either the right or left cursor.

– Cursor «A / B» : this option is used to exclusively move the A / B cursor.

– Cursor «A + B» : move the both cursors simultaneously, without modifying their distance.

Tooltips The current cursor is associated with a Tooltips (activated in the Dis-play > Preferences ... menu) which gives the coordinates of the point of the trace showed by the current cursor, as well as the direction of the A and B cursors. The active cursor is underlined.

When you click on the cursor or when the focus stays more than 1 sec-ond on it, a bigger tooltip is displayed, giving more informations (loss, reflectance, slope etc.).

NOTEFor PMD traces, you can position only one cursor (A).

NOTEYou cannot make a cursor selection with the PMD traces.

48 FiberCable Manual 7OFSMAN12/05

Page 71: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesCursors

Trace information Once the A and B cursors are positioned on the trace, their respective positon and the difference between the two locations are displayed at the bottom of the trace.

NOTEThe cursors data are different according to the type of trace ope-ned.

Fig. 18 Display values for the A and B cursors

B - A value

Cursor B value

Cursor A value

FiberCable Manual 7OFSMAN12/05 49

Page 72: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesSetting Display Preferences

Setting Display PreferencesSeveral display parameters can be set as preferences to allow you to optimize visualization of the results on the trace.

– Select Preferences from the Display menu. The Trace display dialog box is opened.

– Click on the Default button to select the default values or choose each parameter as explained below.

– Click on the Font button to select the desired text format.– Activate / Disactivate the Tooltips radio button to show / hide the

informations given by tooltips.– Click on the OK button to confirm the displayed values and to

return to the trace display.– Click on the Cancel button to cancel the modification and come

backto the trace display.– Other parameters are displayed and can be changed according to

the trace type (OTDR / WDM-OSA / PMD / CD / ATS).

Display preferences for

OTDR traces

– Enter the required values for the trace top and bottom margins2.– Check the boxes to select the results to be displayed on the trace:

– Events– Distances– Slopes– Values– Units– Markers name– Write in vertical (in case of dropping out of place - needs a font

allowing this function)– Print results in black (for color printer)

– Results on all the traces: allows to display the measurement results on all traces in the same screen.

– Select the distance unit (Meters / Km / Feet / Kfeet / Miles)

2.Define the display zone

50 FiberCable Manual 7OFSMAN12/05

Page 73: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesSetting Display Preferences

– Choose the inversion axis for both-end measurement.

Display preferences for

WDM/OSA traces

– Select the parameter used in X: frequency in THz or wavelength in nm.

– Select the unit used in X: nm, THz or GHz.– Set the top and bottom margins of the trace (in dB).– Choose to show or hide the horizontal cursors.

Fig. 19 Display preferences for OTDR traces

Fig. 20 Display preferences for WDM traces

FiberCable Manual 7OFSMAN12/05 51

Page 74: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesSetting Display Preferences

Display preferences for

PMD traces

– Select the wavelength unit: nm or THz. – Select the distance unit: Kilometers / Kilofeet / Miles

Display preferences for

CD traces

– Select the CD trace to display when opening the file: Dispersion, Delay, Slope or OTDR.

– Select the distance units: meters, kilometers, feet, kfeet or miles.

– You can notch the corresponding case to display: - Markers values - Vertical write

Fig. 21 Display preferences for PMD traces

Fig. 22 Display preferences for CD traces

52 FiberCable Manual 7OFSMAN12/05

Page 75: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesDisplaying open trace files

Display preferences for

ATS traces

– Select the wavelength unit: kilometers, kilofeet or miles.

– Set the top and bottom margins of the trace (in dB),

Display preferences for

fox results

– Notch Display references to display the reference measurements realised.

– Select the distances unit (Meters / Kilometers / Feet / Kilofeet / Miles)Clicking on the Default button will set the distances unit in Kilome-ters.

Displaying open trace files

Navigating between open

files

Whenever you open a trace file, the trace becomes the active display and occupies all the trace display window. Its name is shown in the title bar.

Fig. 23 Display preferences for ATS traces

Fig. 24 Display preferences for FOX results

FiberCable Manual 7OFSMAN12/05 53

Page 76: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesDisplaying open trace files

– If you open another trace file, it is superimposed on the previously opened file and becomes the active display.

– If you want to reselect the first display, select its filename from the Window menu. It will then become the active display again

The name of the active displayed file is preceded with a in the Window menu and it is shown in the title bar.

Displaying more than one file at a

time

You can display more than one open file at the same time to simplify comparisons. Two methods are available: Cascade or Tile, selected from the Window menu.

– Using the cascade method displays all the open files in cascade with the active display always on the top of the stack.

– Using the tile method re-scales the displays to show all the open files in the trace display window.

In tile and cascade mode display

– To choose which file is the active display, left-click on the title bar of the required file (the color of the title bar changes).

– To reposition the active file in the display window, left-click on the title bar of the displayed file and drag it to a new position.

– To quit the tile or cascade mode and use all of the trace display window for a file, double left-click on the title bar of the required file.

Displaying Multi traces

(OTDR / WDM -OSA)

It is possible to display up to 12 traces simultaneously (OTDR or WDM/OSA) in the same window. To do this, one of the traces being opened:

– From the Display menu, select the Multi-traces > Add trace option.The Open a trace file window is displayed.

– Select the required traces. They are then displayed in the same window but in different colors to the active trace. All traces have 2 dB shift.

54 FiberCable Manual 7OFSMAN12/05

Page 77: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesDisplaying open trace files

You can also directly open several traces, once the software is open:

– Click on Open in the File menu– Select the required traces (using the Ctrl or Shift key).– Click on the Open in the same window button

For each trace are provided, on the left:

– Its trace parameters.– A radio button to select which is the active trace.

NOTETo select several files at the same time in the Open dialog box, click on the Ctrl key and maintain while you select the files.

For a consecutive files list,press and hold down the Shift key while you select the first and the last file of the list.

Fig. 25 Multi-traces display mode

Display / Hide trace

Color selectors

Swap active trace with selected trace

FiberCable Manual 7OFSMAN12/05 55

Page 78: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 4 Displaying TracesTo copy the trace to a word processing file

– A checkbox to select whether or not the trace is displayed. Un-checking this checkbox removes the trace from the display window.

– A color selector showing the color of the corre-sponding trace and allowing to modify it: double clicking on a color selector opens a color palette allowing you to select the color of the corre-sponding trace.

Removing a trace To remove a trace from a Multi-traces display:

– from the Display menu, select Multi-traces > Remove trace ..., – select the trace to remove from the list displayed.– click the OK button.

To copy the trace to a word processing file1 Right-click in the trace window, then select Copy trace.

2 Open the destination file (Word for example) and select Edit > Special paste.

In the Special paste menu: - select Image (metafile), then click on OK to copy the trace, - select Text, then click on OK to copy the trace parameters.

NOTEIf you open traces which are not compatible (index, measurement module or pulse value different), a dialog box informs you and you can choose to cancel or continue the files opening.

56 FiberCable Manual 7OFSMAN12/05

Page 79: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR Traces

5

This chapter describes the analysis of OTDR traces.

Topics discussed in this chapter are as follows:

– "Trace display window" page 58– "Defining Calculation Parameters" page 60– "Automatic Event Detection and measurements" page 61– "Using Markers" page 62– "Manual measurements" page 69– "Differences between traces" page 75– "Both End measurement" page 76– "Multi-traces analysis" page 78– "Opening an OEO result from a 6000/8000 Platform" page 79– "Results Table" page 80– "To copy the results to a word processing file" page 84

FiberCable Manual 7OFSMAN12/05 57

Page 80: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesTrace display window

Trace display window

Trace display The analysis window includes:

– On the left, the acquisition parameters are displayed .– On the right, the trace is displayed– At the bottom, the cursors information.

– The results / alarms table can be displayed in a seperate window or at the bottom of the trace.

Fig. 26 Trace analysis window

Cursors A and B position Distance and loss between A and B cursors

Table alamrs

Trace parameters Small trace

Table resultss

Tooltip

58 FiberCable Manual 7OFSMAN12/05

Page 81: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesTrace display window

Cursors position indicator

The status bar, at the bottom of the trace, gives the values of the cur-sors A and B.

Cursors Values

Cursor A - Distance from the origin of the fiber to the cursor A.- Attenuation at the cursor A.

Cursor B - Distance from the origin of the fiber to the cursor B.- Attenuation at the cursor B.

Cursor B - A - The distance difference (in km) between cursors A and B.- The attenuation difference (in dB) between cursors A and B.- The linear attenuation (in dB/km) between cursors A and B.

Fig. 27 Values of the cursors A and B

NOTEThe differences between A and B are negative if the cursor A is positioned after cursor B.

/

FiberCable Manual 7OFSMAN12/05 59

Page 82: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesDefining Calculation Parameters

Defining Calculation ParametersBefore you make measurements you can define specific parameters you want to use, depending on the device used to acquire the trace.

Defining parameters

1 Select Calculation parameters … from the Calculation menu. The General parameters box is displayed:

2 Enter the required values or left click on the Default button to select the default values.

3 Click on the OK button to accept the displayed values and return to the trace display.

Fig. 28 Calculation parameters

NOTE

For reflectances you have to select one of the proposed value.

For splices you can either select a defined value or enter a value in the corresponding field.

For slopes, masks and ghosts you have to enter the required value in the corresponding fields

60 FiberCable Manual 7OFSMAN12/05

Page 83: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesAutomatic Event Detection and measurements

Event detection criteria

The detection of an event depends on the selected attenuation and reflectance threshold of the event. The event will be displayed if one of these values is above a threshold. Both results for an event will be dis-played if both can be calculated.

The event reflectance is always measured unless all the elements of the event cannot be measured, e.g. peak saturation or an event lost in noise. In such cases instead of giving the exact calculated reflectance value e.g. -30 dB, the display shows >-30dB to indicate that the reflec-tance is worse than -30 dB.

It is also possible to detect two events that are very close together, even though all the elements of each event cannot precisely be mea-sured.

Automatic Event Detection and measurementsYou can quickly locate all the events detected on the trace using auto-matic measurements as an OTDR will do it.

An automatic measurement detects all the events on the trace, dis-plays the measured value for each event, and generates an event result table.

To start an automatic measurement of a displayed trace define the specific calculation parameters you want to use for the measurement and press the button or select Automatic measurement from the Calculation menu or use the Shift + A keys.

The trace is displayed with all the detected events and the measure results associated.

– A marker is automatically set on each detected event.

NOTEThe values followed by H-M are only valid for Helios, the MTS and the RTU.

FiberCable Manual 7OFSMAN12/05 61

Page 84: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesUsing Markers

Using MarkersYou can position markers on the trace to indicate the exact position of detected faults so that you can quickly locate the same positions after repair or measurement using different calculation parameters.

Markers mode To position or modify the markers you must be in markers mode. To access this mode, click on the button in the Tools bar or select the Markers mode option in the Markers menu.

Fig. 29 Automatic Measurement results

Reflectance End of fiber

Splice Slope

Number of Detected events

NOTEOnce you have selected the marker insertion mode you will not be able to use cursors unless you hide the markers (see below) or you hold down the Ctrl key.

62 FiberCable Manual 7OFSMAN12/05

Page 85: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesUsing Markers

Adding Markers Use the following steps to position markers on the trace:

1 Access Markers mode (see below).

2 Move the cursor to the required position for the marker and left-click. A blue marker symbol is positioned on the trace and the measurements relative to the marker are made and displayed: - slope before and after the marker - attenuation on the marker - and/or reflectance peak.

3 Repeat step 2 until you have positioned all the markers you require.

Hiding and Displaying

Markers

Once you have added markers you can toggle between displaying them or hiding them. To do this press the button or select Markers from the Markers menu. If markers are displayed they will be hidden and if they are hidden they will be displayed.

Repositioning a Marker

To move a previously positioned marker:

1 Access Markers mode (see "Markers mode" page 62).

2 Carefully position the cursor on the marker you want to move.

3 When the cursor is correctly positioned it changes to a .

4 Press and hold the left mouse button, drag the marker to the required position and release the mouse button

The marker is repositioned and the measurements relative to the new location are updated.

Deleting a marker To delete a previously positioned marker:

NOTETo accurately position markers it is often easier to first zoom-in on the display (refer to “Zoom-in” page 41).

FiberCable Manual 7OFSMAN12/05 63

Page 86: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesUsing Markers

1 Access Markers mode (see "Markers mode" page 62).

2 Carefully position the cursor on the marker you want to delete.

3 When the cursor is correctly positioned it changes from a to a .

4 Left-click the mouse button.

The marker is deleted and the measurements are updated.

Deleting all the markers and the

results

Press the button or select the option Delete Marker in the Markers menu, to delete all the markers on a trace. Confirmation of the deletion is then required.

This operation also deletes all measurement results associated with the markers.

Canceling last actions on

markers

To cancel the last action made on marker (add a marker, delete marker etc.), use the button.

The successive actions on markers are memorized, so pressing several time will cancel the successive previous actions.

Precise positioning of a

marker

1 In the Define Marker dialog box, enter the distance with respect to the origin of the trace and, if known, the longitude and latitude of the point.

2 If required, enter the marker name.

3 Click on the Add button: the marker is added in the list.

4 Click on Apply: the marker appears on the trace.

Modifying a marker

1 In the Markers List field, choose the marker to be modified.

2 Modify the marker positioning parameters or its name.

3 Click on the Modify button, then click either the Apply or OK button.– The Delete button is used to delete the current marker

64 FiberCable Manual 7OFSMAN12/05

Page 87: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesUsing Markers

– The Apply button is used to apply the modification of a parameter to the current marker without closing the Define Markers window.

– The Cancel button is used to cancel the modification of a current marker parameter until a save (by Apply) operation has been carried out.

– The OK button is used to save the current marker parameters and close the Define Markers window.

Markers group You can select a group of markers in order to move it on the trace, copy it to another trace, copy the characteristics of the markers in a spread-sheet file or a text file, etc.

Selection of a marker group

1 Press the button or select Shift Marker Group from the Markers menu. The cursor is followed by the mark.

2 Draw a rectangle around the markers you want to insert in the group.

NOTEPressing the Ctrl key allows you to select non consecutive markers in the group.

Fig. 30 Marker group selection

FiberCable Manual 7OFSMAN12/05 65

Page 88: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesUsing Markers

The selected markers are black. The group is defined by a rectangle with a double-lined edge on the right-hand side indicating that a group is drawn from this point.

Marker group properties

– You can display or not the marker group selection: click on the button or check the Shift marker group option of the Marker

menu.– The group will be saved even if you modify its marker locations or

erase some of them.

Possible Actions on the marker group

When a marker group is selected, a right-click on the trace window gives access to the following menu:

This menu options (accessed by a right-click on the trace) allows to:

1 Cancel the marker group selection.

2 Copy the selected markers in the clipboard.

3 Cut the selected marker groups and copy them to the clipboard in order to paste them to a trace, a spreadsheet or a text file.

4 Paste markers from the clipboard to the current trace, a spread-sheet or a text file.

5 Paste markers from the clipboard to the current trace, a spread-sheet or a text file, with distance inversion (for both end measure-ment).

Fig. 31 Contextual Markers menu

The same commands are also available in the Markers menu

66 FiberCable Manual 7OFSMAN12/05

Page 89: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesUsing Markers

To cancel a marker group

1 If necessary, click on the button to activate the Marker group function.

2 Click in the trace window outside the group, or select Cancel marker selection after a right-click in the trace window.

To shift the marker group on the trace

If, for example, you want to shift the group of markers on the trace to compensate for the addition of launch cables, do as follows:

1 If necessary, click on the button to activate the Marker group function.

2 Click inside the group, when the cursor is a : you can then shift the group along the trace.

To widen the marker group on the trace

If you want to widen the group of markers on the trace to compensate for a measurement made on the same cable, but with different condi-tions (index, lambda, etc.), do as follows:

1 If necessary, click on the button to activate the Marker group function.

2 Click on the right-edge of the group, when the cursor is a : you can then widen the group on the trace.

To copy the marker group to another trace

1 Select Copy selected markers after a right-click in the trace window.

2 Open the trace on which you want to copy the marker.

3 Select Paste markers selection after a right-click in the trace window.

The group is copied on the trace: you can now shift it or widen it to adjust the position of the markers.

To copy the marker group to another trace

with inversion of the markers

In Both End measurement (see "Both End measurement" page 76)you can copy the markers of the O->E trace on the inverted E->O trace. In this case, use the preceding procedure with the Paste and invert markers selection.

FiberCable Manual 7OFSMAN12/05 67

Page 90: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesUsing Markers

To copy the marker group to a word

processing file or a spreadsheet file

To copy the the marker group characteristics to a word processing file or a spreadsheet program, such as Microsoft Excel:

1 Select Copy selected markers after a right-click in the trace window.

2 Open the word processing or spreadsheet file

3 Select Paste.

The marker group characteristics are copied. For each marker, the fol-lowing information is given:

To copy the marker group from a text or a

spreadsheet file to a trace

1 Select the lines concerning the markers you want to copy and the characters of the interested columns (to copy markers the first column giving distances is compulsory).

2 Select the Edit > Copy function.

NOTEThe marker End of fiber having no equivalent in the E->O trace, it must not be selected in the marker group.

Column 1 Distance of the marker from the origin of the trace (in meters). This information is necessary. Information in the following columns is optional.

Column 2 Marker name selected in the Define Marker box.

Column 3 Longitude in decimal degrees (default: 0)

Column 4 Latitude in decimal degrees (default: 0)

Column 5 Identifier of the element in the schematic.

Column 6 Attribute of the element in the schematic.

Column 7 Bellcore characteristics (corrector factor).

Column 8 Bellcore characteristics (landmark code).

Column 9 Bellcore characteristics (mode field diameter).

Column 10 Bellcore characteristics (sheath marker entering land-mark).

Column 11 Bellcore characteristics (sheath marker leaving land-mark).

68 FiberCable Manual 7OFSMAN12/05

Page 91: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesManual measurements

3 Open the trace in which you want to copy the markers.

4 Right click on the trace and select Paste marker selection, or Paste and invert marker selection to copy the markers on the trace without or with inversion.

Manual measurements

Measuring the Slope of the Trace

You can easily measure the slope or linear attenuation of a section of the trace contained between cursors A and B.

To measure the slope or loss:

1 Position the cursors A and B in order to contain the section of the trace you want to measure (See “Cursors” page 47).

2 Press the button or select Slope from the Calculation menu.Red brackets display the origin and end of the section. The linear attenuation calculated is displayed between the markers in dB/km.

You can make as many slope measurements on the trace as you require as long as the sections do not overlap. If the slope measure-ment section overlaps another section previously defined and mea-sured, the new measurement replaces the previous measurement. Any other measurements calculated from this slope measurement are also deleted (refer to “Measuring Discontinuity on the Trace”).

NOTEIf you have not positioned the cursors before starting a slope measurement, the following alert message is displayed: «Impossible slope measurement. You should position two cursors.»

FiberCable Manual 7OFSMAN12/05 69

Page 92: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesManual measurements

Measuring Discontinuity on

the Trace

You can measure the discontinuity (splice ...) between two sections of the trace where you have previously made slope measurements:

1 Make slope measurements on two sections of the trace (refer to “Measuring the Slope of the Trace” page 69).

2 Position cursor A between the two slope measurements at the right position on the event.

3 Press the button or select Splice from the Calculation menu.The result of the measurement is shown on the display with a blue marker indicating the exact measurement location on the trace.

The splice measurement values then remain associated with the trace even if the display is modified (Zoom function, etc.). To erase the splice measurement values you must use the Delete results command (refer to “Deleting all the markers and the results” page 64) or make a new measurement.

Fig. 32 Manual measurement results

Result of splice measurementResult of slope measurement

Result of reflectance

70 FiberCable Manual 7OFSMAN12/05

Page 93: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesManual measurements

Measuring Reflectance on the

Trace

You can measure the reflectance of a Fresnel for a reflective event:

1 Position the cursor A at the base of the peak and the cursor B at the top of the peak of the required Fresnel (refer to “Automatic Event Detection and measurements” page 61).

2 Press the button or select Reflectance from the Calculation menu.The result is shown on the display with purple markers indicating the exact positions that correspond to the reflectance measure-ment.

The reflectance result then remains associated with the trace even if the display is modified (Zoom function, etc.…). To delete this result you can use the Delete results command (refer to “Deleting all the markers and the results” page 64) or make a new measurement.

Measuring the Optical Return

Loss

You can measure the Optical Return Loss (ORL) from a section of the fiber that is the amount of light reflected from the fiber. This value, in dB, is calculated as follows:

To measure the ORL: 1 Position the A & B cursors at the beginning and end of the section of the fiber you want to measure (refer to “Automatic Event Detec-tion and measurements” page 61).

NOTEBefore positioning a cursor, for greater precision, it is preferable to zoom in on the trace (refer to “Zoom-in” page 41).

NOTEIf you have not positioned the cursors before starting a reflectance measurement an alert message is displayed: «Impossible reflectance measurement. You should position two cursors».

ORL 10 Incident energyReflected energy----------------------------------------log=

FiberCable Manual 7OFSMAN12/05 71

Page 94: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesManual measurements

To accurately position a cursor it is often easier to first zoom-in on the display (refer to “Measuring Reflectance on the Trace” page 71).

2 Press the button or select Optical Return Loss from the Calcu-lation menu.The section of the fiber measured is shown shaded green. A measurement result box in the top right-hand corner of the window shows:– the Reflectance Coefficient used (in dB)– the ORL value (in dB)– the Contribution to the reference point (in dB)

The ORL measurement result remains associated with the trace. It stays displayed just until a new measurement is carried out either from the button or by Optical Return Loss in the Calculation menu even if the display is modified (Zoom function, etc.…). To delete the ORL measurement result, press the button or select Optical Return Loss from the Calculation menu a second time.

NOTEIf you have not positioned the cursors before starting an ORL mea-surement the following alert message is displayed: «Impossible Opti-cal Return Loss measurement».

Fig. 33 ORL Measurement

ORL result

72 FiberCable Manual 7OFSMAN12/05

Page 95: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesManual measurements

Measuring the Contribution

Once you have made an ORL measurement you can measure the contribution (in dB) to the overall ORL that a specific reflective event causes. This contribution is measured from the start of the ORL mea-surement.

Use the following procedure to measure the contribution caused by a specific event:

1 Make an ORL measurement on a section of the trace.

2 Position the cursors to indicate the start and end points of the event you want to measure the contribution for.The original position of the start of the ORL measurement is indi-cated with a solid green cursor. The section of the fiber where the event you are measuring is located is shown shaded green and the contribution value to the reference point in dB is displayed in the measurement result box.

The contribution measurement result is not associated to the trace. It stays displayed just until a new measurement is carried out.

Fig. 34 Contribution Measurement

Contribution of event to ORL measurement

Start of ORL

FiberCable Manual 7OFSMAN12/05 73

Page 96: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesManual measurements

Defining a Mask To help you to detect faults on the fiber you can define a mask (or threshold) for a section of the trace that will indicate the first point of the trace that exceeds the selected threshold value.

In order to do this you must first specify the mask threshold value in dB and define the section of the trace where you want to apply the mask.

Use the following procedure to define the mask:

1 Select Calculation parameters … from the Calculation menu.

2 Enter the mask threshold in dB in the Mask field and press OK.

3 Position the cursor A and B at the extremities of the section of the trace where you want to apply the mask.

4 Select Mask from the Calculation menu to test the mask.

The area you defined is represented as a parallelogram:

– If no point of the trace exceeds the selected threshold, the paral-lelogram is green and a test status box is displayed in the top right hand corner of the display giving the selected mask value and an OK status message.

Fig. 35 Mask Test Result

Mask zone delimited by a parallelogram (Green = Good, Red = Bad)

Test status box

74 FiberCable Manual 7OFSMAN12/05

Page 97: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesDifferences between traces

– If the test fails, the parallelogram is red and the status box shows the distance from the start of the fiber to the first point that the trace exceeds the selected threshold and a Bad status message.

To erase the mask, select Mask from the Calculation menu.

Differences between tracesWhen two traces are simultaneously displayed (see "Displaying Multi traces (OTDR / WDM -OSA)" page 54), it is possible to obtain the trace corresponding to the difference, point by point, between the cur-rent trace and the overlaid trace.

To do this, select Difference between traces, in the Display menu. The difference is calculated by using the logarithmic values.

NOTEYou can only have the differences between traces acquired with the same type of OTDR, using the same pulse width, for fibers with the same refractive index. Unless the following alert message is dis-played: «Impossible difference calculation. The traces do not meet the conditions: same indices, same analyzers, same pulse width».

NOTEYou cannot make any calculations on the difference trace from the Calculation menu.

You cannot use the button Difference between traces... if more than 2 traces are opened.

FiberCable Manual 7OFSMAN12/05 75

Page 98: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesBoth End measurement

Both End measurementThe Both End measurement function allows the results of measure-ments made in both directions of the fiber (Origin to End or End to Ori-gin) to be used to obtain true splice and connector loss results.

Measurement Principles

The Both End measurement function uses the Multi-trace function (see “Displaying Multi traces (OTDR / WDM -OSA)” page 54).

The traces obtained form the two measurements (one in each direc-tion) are displayed with event markers. They are first displayed super-imposed, then one of them is inverted (left ↔ right), in order that the markers associated to the same events are on the same horizontal position.

The Both End measurement result table show the following loss types:

– The O → E and O ← E losses correspond to the measurements made in each direction.

– The third value corresponds to the average of the two previous values. It corresponds to the real value of the insertion loss of the event.

Execution of a Both End

measurement

Display of the two traces O → E and O ← E

Use the following procedure to make a both end measurement:

1 Open the trace file of the measurements made from one of the extremities of the fiber you want to measure (preferably O->E).

2 Use the Multi-traces >Add Trace command from the Display menu to select the trace file of the measurements made from the other end of the same fiber (preferably O<-E). See “Displaying Multi traces (OTDR / WDM -OSA)” page 54.

3 If necessary choose the type of inversion for the O<-E trace, in the Display > Preferences menu (see “Defining Calculation Parame-ters” page 60).

76 FiberCable Manual 7OFSMAN12/05

Page 99: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesBoth End measurement

4 If necessary select the launch cables in the Edit trace box called by the File > Edit trace information ... > Cable menu (see “Trace infor-mation” page 49).

5 Select the Both end measurement command from the Display menu to enable measurements from both ends.

The O → E and O ← E traces are automatically aligned when the measurement is started or when a launch cable is inserted. If necessary, shift the traces to align the corresponding events (see “Trace Shift (OTDR / WDM-OSA)” page 44).On the second trace the events are located by a vertical line. These line are markers: if they are not displayed, click on . On the active trace, if necessary: - move the markers to align them with the corresponding line of the second trace. - add new markers if they are missing on the active trace and present on the other trace.

6 Swap the traces using the swap radio button of the trace parame-ters window to select the second trace as the active trace.

7 Make on this trace the required adjustments and measurement as described previously.

Fig. 36 Both end measurement

FiberCable Manual 7OFSMAN12/05 77

Page 100: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesMulti-traces analysis

8 Press the button (or select Events result table from the Display menu) to display the average results of the measurements from both ends of the fiber.

The Both End measurement can be saved to a file (see "Results Table" page 80).

Multi-traces analysisWhen displaying multiple traces (see "Displaying Multi traces (OTDR / WDM -OSA)" page 54), a multi-traces analysis can be generated.

This function is used to compare the automatic measurements from several traces and to complete the detected events onto the active trace.

This analysis also allows to delete markers on the active trace, where the automatic measurement (see "Automatic Event Detection and measurements" page 61) would have detected some by mistake.

Generate a multi-traces analysis

To perform a multi-traces analysis, open several traces in the same window (see "Displaying Multi traces (OTDR / WDM -OSA)" page 54).

– Select the reference trace to activate, notching the corresponding radio button, in order to set the events.

– Select Multi-trace analysis in the Calculation menu.

The cable event configuration dialog box is displayed.

Fig. 37 Results table of a Both End measurement

78 FiberCable Manual 7OFSMAN12/05

Page 101: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesOpening an OEO result from a 6000/8000 Platform

– Enter the distance tolerance: exclusively the events located in this distance range will be considered as identical. this parameter depends on the pulsewidth and resolution.

– Enter the minimum frequency: minimum number of times when the event appears on the displayed traces.

– Click on the Start button to generate the analysis– Click on Exit to close the dialog box.

Opening an OEO result from a 6000/8000 PlatformA OEO result is a file containing 2 traces in a multi-traces displaying mode: 1 file O -> E and 1 file E -> O.

Those results are directly generated from a 8000 Platform.

Operations onto the OEO files

The OEO files allow to:

– perform Both End measurements (see "Both End measurement" page 76)

– generate a multi-traces analysis (see "Multi-traces analysis" page 78)

– display, save and print results (see "Results Table" page 80)

Fig. 38 Multi-traces analysis parameters

NOTEIf you click on the Exit button without having clicked on the Start button previously, the multi-traces analysis is not generated.

FiberCable Manual 7OFSMAN12/05 79

Page 102: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesResults Table

Save one of the 2 traces

You can save the active trace of an OEO file (radio button notched) under a new extension (.sor / .wtk / .txt)

– Click on the Save as... button in the File menu.– Select the directory where you want to save the active trace– Enter a new name for the file– Select the file extension in the pop-up menu Type– Click on Save

Results TableWhenever you make a measurement, an event result table is gener-ated. This table lists all the results of events detected during the mea-surement.

A results table is also available after a both end measurement onto the traces.

Displaying Results Table

To display the results table, click on the button or select Results Table from the Display menu.

This table is interactive and shows the measurement in progress. Any operation on the trace is immediately entered in the table.

Results table content

If the alarm thresholds are validated in the menu Calculation / Calcula-tion parameters ... (see "Defining Calculation Parameters" page 60 )a mes-sage, above the table, gives the global result with respect to the threshold.

To the right side of the table results is displayed the alarms table results.

NOTEYou cannot delete one of the two traces in a OEO file.

80 FiberCable Manual 7OFSMAN12/05

Page 103: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesResults Table

In the first table column, an icon represents the event type:

Fig. 39 Example of Results Table

Icons Description

(green) The analysis didn’t find any out of range results.

The analysis has found at least one out of range result.

Out of range result.

Icons Description

Non-reflective event (ex. splice)

Reflective event (ex. connection)

Ghost reflective event

End of the fiber

No result on this marker. The measurement could not be performed

ORL measurement

Launch cable

Results of the analysis with respect to the chosen alarm thresholds

Event not standard Out of range result Alarms table

FiberCable Manual 7OFSMAN12/05 81

Page 104: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesResults Table

The following information is given for the detected events on a trace:

– The distance from the beginning of the fiber to the event.– The attenuation of the event, or the total loss of the fiber if the

event is the end of the fiber.– The reflectance of the event (or the ORL if an ORL measurement

is made).– The slope before the event.– The distance between the event maker and the previous one.– The total loss up to the event– Any uncertainty about the event.– A comment, if any.

Level of confidence in result table

The following remarks are possible:

Table 5 Level of confidence in results table

Concerning loss measurements

2c manual Result of a manual measurement between the ref-erence and the cursor, “two cursor” method.

5c manual Result of a manual measurement according to the “five cursor” method.

Global The loss displayed is the global result for Fresnels that are not sufficiently separated.

Close evts Several events being too close, only the attenua-tion of the last is displayed.

Concerning slope measurements

Few points Slope measurement using the linear regression method not using many acquisition points.

2 points Slope measurement using the “two point” method.

82 FiberCable Manual 7OFSMAN12/05

Page 105: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesResults Table

Saving Results After a trace analysis, the results can be saved in a text file format in order to integrate them in a report or in a spreadsheet to make statis-tical analysis.

Use the following steps to save your results:

1 Select Save Results from the File menu.

The Save as... dialog box is displayed.

2 Select the source drive and the directory where you want to save the file.

3 In the File name field, enter the file name you require: the .xls extension is provided by default.

4 Select the file format required

5 Left click on the Save button.

Results file contents

The results file contains the following information, depending on the type of OTDR used for the measurement:

Identification of the file and of the measurement:– access path of the file and file name– measurement title, acquisition date & time, device, wavelength,

pulse width, number of averages, acquisition time.– range, index of refraction, cable identifier, fiber n°, way, OTDR

module used.

For each event detected, for normal measurement: – the event number– its type: splice, launch cable, etc.– its distance from the start of the fiber,– the distance from the start of the fiber of reflectance peaks– its reflectance (for a reflective event), – the attenuation due to the event– the relative distance with the previous event– the distance from the start of the fiber, of the start and end of the

slope before the event

FiberCable Manual 7OFSMAN12/05 83

Page 106: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 5 Analyzing OTDR TracesTo copy the results to a word processing file

– the linear attenuation (slope) in dB/km, – the segment loss, – the link budget, – the uncertainty.– the comment

For each event detected, for a both end measurement– the event number & its type for O → E measurement,– the event number & its type for E → O measurement,– its distance from the start of the fiber for O → E measurement

only,– the attenuation in dB for O → E measurement,– the attenuation in dB for E → O measurement,– the average attenuation of the O → E and O ← E measurements,– the linear attenuation per unit length (slope) before the event for O

→ E measurement,– the linear attenuation per unit length (slope) before the event for E

→ O measurement,– the average attenuation per unit length of the O → E and O ← E

measurements.

To copy the results to a word processing file1 Right-click in the trace window, then select Copy results.

2 Open the destination file (Word for example) and click on paste or select Edit > Special paste.

3 In the Special paste menu: - select Text, then click on OK to copy the results.

84 FiberCable Manual 7OFSMAN12/05

Page 107: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 6 Analyzing WDM / OSA traces

6

This chapter describes how to analyze optical spectrums with a Fiber-Cable OFS-200 Software.

Topics discussed in this chapter are as follows:

– "Trace display" page 86– "Defining Calculation Parameters" page 87– "Calculations carried out on the spectrum" page 89– "Results Table" page 91– "Exceeding the alarm thresholds" page 95– "Comparing traces" page 95

FiberCable Manual 7OFSMAN12/05 85

Page 108: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 6 Analyzing WDM / OSA tracesTrace display

Trace display

Trace display When a WDM trace has been opened, the display shows:

– on the left, the trace parameters used during acquisition.– on the right, the trace– on the bottom, data relatives to cursors A and B.

On the Trace display window: – The horizontal axis shows the frequency or wavelength (see

“Setting Display Preferences” page 50). – The vertical axis is the power in dBm.

Fig. 40 Optical spectrum Display

Measurement results

Position of cursors A & B and power at the point of intersection with the trace

Trace parameters Grid steps

Distance and loss between cursors A & B

Power composite between cursors A & B, in dBm and µW

Choice of cursor mode and indication of the chosen mode (A, B or A+B)

86 FiberCable Manual 7OFSMAN12/05

Page 109: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 6 Analyzing WDM / OSA tracesDefining Calculation Parameters

Cursors position indicator

The status bar, at the bottom of the trace, gives the values of the cursors A and B.

Fig. 41 Values of the cursors A and B

Defining Calculation ParametersBefore you make measurements you can define the following specific parameters:

– alarm threshold on the Power level (in dBm).– alarm thresholds for Statistics on Delta Signal/Noise ratio, Delta

Power level and Delta frequency.– alarm threshold on the Power level for trace comparison.– the OSNR measurement parameters:

Cursors Values

Cursor A - Frequency or wavelength (according to the unit) of the cursor A- Power level of the cursor A (dBm)

Cursor B - Frequency or wavelength (according to the unit) of the cursor B- Power level of the cursor B (dBm)

Cursor B - A - Difference (of frequency or of wavelength) between the cursors A and B.- Difference of power level between the cur-sors A and B.

NOTEThe wavelength difference result is negative if the cursor A is posi-tioned after cursor B.

FiberCable Manual 7OFSMAN12/05 87

Page 110: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 6 Analyzing WDM / OSA tracesDefining Calculation Parameters

Noise measurement distance, that is to say the difference between the frequency corresponding to the highest point of the channel and the frequency corresponding to the reference point for the noise: 25 / 50 /100 GHz (about 0,2/ 0,4/ 0,8 nm at 1550 nm). Noise measurement method: side of the peak where the reference point has been taken for the noise: to the right or to the left. For the method "Left+Right", it is the average value calculated from the levels obtained to the right and the left that is used.

– threshold for detecting channels on the OSA-155/160/200.– delta wavelength and delta level for importation on the OSA-155

To define these parameters select Calculation parameters … from the Calculation menu. The Calculation parameters box is displayed.

1 Check the parameters on which you wish to place an alarm threshold and enter the value of this threshold. A warning appears in the results table when these thresholds have been exceeded (see “Exceeding the alarm thresholds” page 95).

2 Select the distance of noise measurement (25, 50 or 100 GHz) and the noise measurement method (Left, Right, or Left+Right).

3 In the case of a spectrum acquired on an Acterna OSA-155, OSA-160 or OSA-200 enter the channel detection threshold.

4 In the case of a spectrum acquired on an Acterna OSA-155 enter the wavelength and level difference required for the importation.

5 Left click on the OK button to accept the displayed values and return to the trace display.

Noise measurement distance:25 / 50 / 100 GHz 0,2 / 0,4 / 0,8 nm

Noise level with reference point: - to the left- to the right

88 FiberCable Manual 7OFSMAN12/05

Page 111: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 6 Analyzing WDM / OSA tracesCalculations carried out on the spectrum

Calculations carried out on the spectrum

MTSe Série 5000 traces

The following parameters are calculated from the spectrum resulting from the MTS 5x:

– the tilt gain and gain slope for the channels as a whole or between the cursors A and B if they are positioned.

– the total power between the cursors A and B.– the signal/noise ratio.

These results are displayed on the trace and in the results table.

To display a result on a trace, select it in the Display menu (Composite Power, Total Power, Tilt and Gain Slope).

Fig. 42 Calculation parameters

FiberCable Manual 7OFSMAN12/05 89

Page 112: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 6 Analyzing WDM / OSA tracesCalculations carried out on the spectrum

To calculate a result or update it after moving the cursor, select it from the Calculation menu or click on the corresponding icon:

Total power calculation

Tilt gain and gain slope calculation

OSA-155, OSA-160, OSA-200 traces

There are no calculations carried out on these traces, but when they are opened a search is made for the channels exceeding the chosen threshold.

NOTEIf the display of a result parameter is not selected in the Display menu, this parameter cannot be calculated. It is in grey in the Calcu-lation menu. This is to avoid erasing results that have not been reg-istered.

90 FiberCable Manual 7OFSMAN12/05

Page 113: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 6 Analyzing WDM / OSA tracesResults Table

Results TableWhenever you make a measurement a results table is generated con-taining the results of each channel detected.

To display this table, click on the button or select Results Table from the Display menu.

It is possible to choose the channels to be displayed in the table, sort the displayed data, display relative results with respect to a selected channel, display the statistics carried out (if the trace is obtained by multiple acquisitions).

Table contents without statistics

In the absence of statistics the parameters given for each channel are as follows:

1 Channel number (the number of detected channels is given in the first column header).

2 Frequency or wavelength (Lambda) of the channel according to the chosen unit.

3 Spacing between the channels.

4 Power level of the channel in dBm.

5 Noise level in dBm.

6 Signal/Noise ratio for the channel in dB.

7 Channel power / Composite power ratio (P/Pcomp) in %.

Fig. 43 Results table (without statistics) with an alarm

FiberCable Manual 7OFSMAN12/05 91

Page 114: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 6 Analyzing WDM / OSA tracesResults Table

The contents of the last five columns of the table will be different if a display of the statistics is requested. They will indicate the current value, average value, max. value, min. value, and standard deviation of the parameter for which the statistics have been calculated (fre-quency or wavelength, level or signal/noise ratio).

Choice of channels

displayed in the table

In the Results menu, choose the channels for which you wish to see the results displayed in the table:

– All channels– Selection of channels between A and B cursors– Selection of channels in the user-defined grid (see “Grid (OTDR /

WDM)” page 41)

Results sorting By default, the results are classified by channel number in ascending order.

To modify the way in which sorting is carried out, select Results sorting in the Results menu, then choose the desired sorting criterion:

– Channel number– Frequency / Lambda– Level– SNR

Display of relative results

The table usually gives the results in absolute values. To obtain these results as relative values, that is with respect to the reference channel, do the following:

– In the Results menu, choose Channel related result ... : a dialog box enables you to choose this channel among those displayed in the table.

Link between the trace and the table

If you click on a channel in the table, it is highlighted in blue, and on the trace the active cursor (A or B) moves to the channel correspond-ing to this table of results.

92 FiberCable Manual 7OFSMAN12/05

Page 115: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 6 Analyzing WDM / OSA tracesResults Table

Successive addressing of

channels according to the

sort method

On the trace and in the table, it is possible to make the cursor pass successively from one channel to another one according to the selected sort order. To do this:

– choose the cursor A or B for use on the trace.– click the key (or choose Peak search in the Calculation menu)

to go to the max. amplitude channel.– click either the or keys (or choose Next channel or

Previous channel in the Calculation menu) to make the cursor jump back to the previous channel or on to the following channel.

Table contents with statistics

The Statistics menu allows you to select the statistic results:

– on Frequency (or wavelength), – on Level, – on Signal Noise Ratio– on frequency and level (Mixed statistics)

According to the selected statistic, the table displays for each channel:

Table 6 Table Contents according to the statistic menu

No statist Freq or Lambda Level Mixed SNR

Channel Channel Channel Channel Channel

Freq. or Lambda

Freq. or Lambda

Freq. or Lambda

Freq. or Lambda

Freq. or Lambda

Spacing Spacing or L ref or F ref a

a. L ref or F ref used to detect alarms

Level F or L min SNR

Level F or L Avg Avg. P. F or L Max Avg. SNR

Noise F or L max Max P. Level Max SNR

SNR F. or Min L. Min P. P min Min SNR

P/P comp Sdev b F or L

b. Standard deviation

Sdev P P Max Sdev SNRc

c. Signal Noise Ratio

FiberCable Manual 7OFSMAN12/05 93

Page 116: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 6 Analyzing WDM / OSA tracesResults Table

Saving results After a trace analysis, the results can be saved in a text file format in order to integrate them in a report or in a spreadsheet to make statis-tical analysis.

Use the following steps to save your results:

1 Select Save Results... from the Results menu.The Save as ... dialog box then appears.

2 Select the location and directory in which the file will be saved.

3 Enter the name of the file: by default, a .txt is proposed. However, you can enter a filename extension corresponding to your spread-sheet (for example, .xls).

4 Click the Save button.

Results file contents

All the results and statistics that have been carried out are saved in the file (for each detected channel):

– the frequency (Freq.)– the average frequency (F avg), min. frequency (F Min) and max.

frequency (F Max)– the frequency standard deviation (Sdev F)– the space interval with the previous channel (spacing)– the power level (level)– the average power (P avg), min. power (P Min) and max. power (P

Max)– the power standard deviation (Sdev P)– the noise level (Noise)– the signal/noise ratio (SNR)– the average signal/noise ratio (SNR avg), min. signal/noise ratio

(SNR Min) and max. signal/noise ratio (SNR Max)– the standard deviation on the signal/noise ratio (Sdev SNR)– the total power/composite power ratio in % (P/Pcomp)

94 FiberCable Manual 7OFSMAN12/05

Page 117: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 6 Analyzing WDM / OSA tracesExceeding the alarm thresholds

Exceeding the alarm thresholdsAn alarm indicator appears in the table if the results exceed the alarm thresholds chosen in the Calculation > Calculation parameters... menu:

Comparing tracesOnce you have displayed a trace you can display a second trace in the same window. This is very useful for comparing the results of acquisi-tions before and after a repair or to detect changes occurred between acquisitions. You can also generate a new trace of the differences between an active trace and a reference trace.

Opening an overlay trace

To set another overlay trace, use the multi-traces display command (see “Displaying Multi traces (OTDR / WDM -OSA)” page 54).

Once 2 traces are displayed, click on the radio button of the trace to activate.

Trace resulting from difference between traces

When two traces are simultaneously displayed, it is possible to obtain the trace corresponding to the difference, point by point, between the current trace and the overlaid trace.

To do this, select Difference between traces, in the Display menu.

The difference is calculated by using the logarithmic values.

General indicator of a threshold exceeded on the channel (in the first column).

Indicator of a threshold exceeded regarding Delta Level sta-tistics.

Indicator of a threshold exceeded regarding Delta Frequency statistics.

Indicator of a threshold exceeded regarding Delta SNR sta-tistics.

FiberCable Manual 7OFSMAN12/05 95

Page 118: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 6 Analyzing WDM / OSA tracesComparing traces

NOTEYou can only have the differences between traces acquired with the same type of instrument, using the same pulse width, for fibers with the same refractive index. Unless the following alert message is dis-played: “Impossible difference calculation. The traces do not meet the conditions: same indices, same analyzers, same pulse width.”

NOTEYou cannot make any calculations on the difference trace from the Calculation menu.

NOTEYou cannot use the option Difference between traces... if more than 2 traces are opened.

96 FiberCable Manual 7OFSMAN12/05

Page 119: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 7 Analyzing PMD traces

7

This chapter describes how to analyze with a FiberCable OFS-200 software, PMD results acquired with an JDSU MTSe Série 5000 analyser equipped with a 5073PMD (or 5073 WDM-PMD) module.

Topics discussed in this chapter are as follows:

– "Trace display" page 98– "Alarm thresholds" page 100– "Results Table" page 102

FiberCable Manual 7OFSMAN12/05 97

Page 120: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 7 Analyzing PMD tracesTrace display

Trace display

Trace The genral contents of a PMD trace are: the trace, its parameters, the cursor position, the mode (FFT or Drift) and the results table.

The trace displayed shows:

– The PMD delay (in ps), with FFT mode.

Fig. 44 PMD results Display

Trace (with FFT method)Trace parameters

Position of the cursor

Trace selection (FFT / Drift)

Results table (and eventually statistics)

98 FiberCable Manual 7OFSMAN12/05

Page 121: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 7 Analyzing PMD tracesTrace display

Cursor position indicator

The status bar, at the bottom of the trace, gives the values of the cursor A.

Cursors To move the cursor use the mouse or the direction arrow keys. The coordinates of its intersection with the trace are indicated in the asso-ciated tooltip, if the function is validated in the Display> Preferences ... menu.

Data associated with the cursor are:

– delay and amplitude for the FFT method

To position a reference cursor click on the place required: the contin-uous line changes in a dotted line. The coordinates of its intersection with the trace are indicated below the trace.

To move this reference cursor place the current cursor on it (the then becomes ), then click and drag, without releasing the mouse button, to the required position.

Fig. 45 Values of the cursor A

Cursor Values

Cursor A (FFT)

- PMD delay.- Intensity

Cursor A (DRIFT)

- Acquisition number- PMD delay and coefficient (ps /√km)- PMD 2 delay and coefficient

FiberCable Manual 7OFSMAN12/05 99

Page 122: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 7 Analyzing PMD tracesAlarm thresholds

Alarm thresholdsThresholds can be entered in the Calculation > Threshold ...menu:

Three options are available:

– None: no alarm selected. – Predefined (Rate info): thresholds on PMD delay are automatically

calculated and adjusted according to the rate information selected: OC-1 (2000 ps), OC-3/STM-1 (640 ps), OC-12/STM-4 (160 ps), OC-24 (80 ps), OC-48/STM-16 (40 ps), OC-192 / STM-64 (10 ps), OC-768 / STM-256 (2,5 ps).

– Manual: you have to notch the parameter with an alarm (PMD Delay, PMD Coeff, PMD2 Delay, PMD2 Coeff) and to enter the corresponding threshold.

Fig. 46 Positioning the cursor on a trace

Cursor

Results tableData of the cursor

100 FiberCable Manual 7OFSMAN12/05

Page 123: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 7 Analyzing PMD tracesAlarm thresholds

If the alarm thresholds are on, a message is displayed above the trace parameters showing if a result exceed the threshold.

:

Fig. 47 Alarm thresholds

Fig. 48 Example: results table with statistics

Result exceeding the threshold

Alarm message relative to thresholds

FiberCable Manual 7OFSMAN12/05 101

Page 124: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 7 Analyzing PMD tracesResults Table

Results Table

Displaying Results Table

A results table is generated for each measurement. It displays the four following parameters: PMD delay and coefficient, second order PMD delay and coefficient.

If the statistics are selected in the Display menu (and if the trace is obtained by multiple acquisitions) the table shows for every parame-ters: mean, min.,and max. values and standard deviation.

To display/erase this table, click on the button (or notch / unnotch Results Table from the Display menu).

The results table is automatically updated and fitted to the selected measurement method. It is interactive: every operation carried out on the trace is immediately entered in the table.

Saving results After a trace analysis, the results can be saved in a text file format in order to integrate them in a report or in a spreadsheet to make statis-tical analysis.

Use the following steps to save your results:

1 Select Save Results... from the File menu.

Icons Description

(green) No threshold exceeded.

General indicator of at least one threshold exceeded.

Indicator on a result exceeding the threshold.

NOTETo save the statistics with the results, previously click on Statistics in the Display menu.

If statistics is not selected, the file contents will not include those statistics.

102 FiberCable Manual 7OFSMAN12/05

Page 125: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 7 Analyzing PMD tracesResults Table

The Save as ... dialog box then appears.

2 Select the folder in which the file will be saved.

3 Enter the name of the file: by default, a .txt format is proposed but you can enter another extension (.xls etc.).

4 Click the Save button.

Results file contents

The file contains the following results:

– Path and file name– Measurement title, acquisition date and time, device type– Wavelength, number of measurements, averaging– Coupling mode, Test point– Measurement results– If you save the results with statistics, the file displays all the inter-

mediate measures.

FiberCable Manual 7OFSMAN12/05 103

Page 126: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 7 Analyzing PMD tracesResults Table

104 FiberCable Manual 7OFSMAN12/05

Page 127: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 8 Analyzing CD traces

8

This chapter describes how to analyze Chromatic Dispersion measu-rement results with a FiberCable OFS-200 Software.

Topics discussed in this chapter are as follows:

– "Trace display" page 106– "Defining Calculation Parameters" page 107– "Alarm thresholds" page 108– "Dispersion, Slope and Delay traces" page 109– "OTDR traces" page 110– "Measurements" page 111– "Results Table" page 113

FiberCable Manual 7OFSMAN12/05 105

Page 128: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 8 Analyzing CD tracesTrace display

Trace display

Trace The display window shows the measurement parameters, the buttons to select the CD trace and the selected trace.

CD Trace selection The default trace to display is selected in the Display / Preference ... menu among the Dispersion, Slope, Delay and OTDR traces.

To display another trace click on the corresponding button on the left of the trace or use the directional arrow keys on the keyboard to scroll the traces.

Fig. 49 CD trace display

Cursor Information

Cursor mode: A, B or A+B

Trace parameters

Trace and color selection

Zero dispersion Wavelength λ0 Slope S0 corresponding to λ0

Trace displayed

Trace and color selection

106 FiberCable Manual 7OFSMAN12/05

Page 129: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 8 Analyzing CD tracesDefining Calculation Parameters

Beside the button selecting a trace a square shows the color of the trace. To change the color and call the color palette, double click on this square.

Cursors position indicator

The status bar, at the bottom of the trace, gives the values of the cursors A and B.

Defining Calculation ParametersBefore you make measurements you can define the calculation parameters.

To define these parameters select Calculation parameters … from the Calculation menu. The Calculation parameters box is displayed.

Fig. 50 Values of the cursors A and B

Cursors Values

Cursor A - Wavelength of the cursor A (nm).- Dispersion of the cursor A (ps/nm)

Cursor B - Wavelength of the cursor B (nm).- Dispersion of the cursor B (ps/nm)

Cursor B - A - Wavelength difference between the cur-sors A and B (nm).- Dispersion difference between the cursors A and B (ps/nm)

NOTEThe wavelength difference result is negative if the cursor A is posi-tioned after cursor Bt.

FiberCable Manual 7OFSMAN12/05 107

Page 130: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 8 Analyzing CD tracesAlarm thresholds

1 Click on the Default button to select the default values, or enter the required values:

– Normalized values: the dispersion figures are normalized to 1 km (i.e. results are divided by the fiber length expressed in km).

– Min. and Max wavelength displayed on the trace and in the table (from 1250.0 to 1650.0).

– Increment: wavelength increment between two results saved in the table (from 0.1 nm).

2 Left click on the OK button to accept the displayed values and return to the trace display.

Alarm thresholdsTo define alarm thresholds you must select Calculation > Threshold ….

Wavelength limits (nm)

If you don’t need to apply the thresholds on the whole wavelength range, notch the case Active and enter the wavelength limits in the Start and Stop fields.

Thresholds To manually enter threshold values on the normalized dispersion and slope values:

– select the option Manuals,– notch the parameter (Dispersion and / or Slope) and enter the

corresponding threshold.– Click on OK to validate the parameters and return to the trace.

Fig. 51 Calculation parameters

108 FiberCable Manual 7OFSMAN12/05

Page 131: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 8 Analyzing CD tracesDispersion, Slope and Delay traces

– Click on Cancel to cancel the parameters.

Dispersion, Slope and Delay tracesThese traces depend on the parameters selected in the Calculation menu: max. and min. wavelengths, increment and normalization at 1 km.

The horizontal axis shows the wavelength in nm.

The vertical axis shows, according to the trace:

– the dispersion values in ps/nm (or in ps/nm.km with normalized values)

– the slope values in ps/nm2 (or in ps/nm2.km with normalized values)

– the delay values in ps (or in ps/km with normalized values)

On the screen the following information is displayed:

– title: the filename (if the result was saved in memory).– in the right upper corner, for the Dispersion: zero dispersion wave-

length λ0 and slope corresponding to λ0.– under the trace: information associated to the cursors A and B on

the corresponding trace: A and B horizontal and vertical values, B-A horizontal and vertical values.

Fig. 52 Alarm thresholds

FiberCable Manual 7OFSMAN12/05 109

Page 132: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 8 Analyzing CD tracesOTDR traces

OTDR tracesThe acquisition has been made on 1 to 4 wavelengths (1310, 1480, 1550 and 1625 nm). The corresponding OTDR traces are displayed with distances on the horizontal axis and attenuations on the vertical axis. A marker is usually placed at the top of each end of fiber peak.

The following informations are displayed:

– below the traces: informations associated to cursors A and B.– on the traces: the location of the markers (if this display is selected

in the Display > Preferences ... menu).

If the Section or Bidir. mode is selected, the reference marker location is also displayed in a frame on the right of the traces.

Marker mode To position or modify the markers you must be in markers mode. To access this mode, click on the button in the Tools bar or select the Markers mode option in the Calculation menu.

A marker is represented on the trace by the symbol . If it has been selected in the Display > Display Preferences ... menu the position of the marker is displayed.

In Marker mode, if several markers are displayed, the cursor is rela-tive to the nearest marker.

Automatic positioning of marker

To automatically place a marker at the top of the reflective event of a trace:

– Access Markers mode.

– Click on the button (or select the command Calculation > Automatic marker): the traces are listed as well as the option All.

– Select All to place automatically a marker on all the traces or select one or several traces to place a marker on it / them.

NOTEIn the marker mode you cannot use cursors unless you hold down the Ctrl key.

110 FiberCable Manual 7OFSMAN12/05

Page 133: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 8 Analyzing CD tracesMeasurements

It is is advised to use the Automatic method to place markers for it is the more precise.

Repositioning a Marker

To move a marker:

1 Access Markers mode.

2 Position the cursor then click.

The marker is moved and results are recalculated with respect to the new position.

Deleting a marker or all the markers

To delete markers on the trace:

1 Access Markers mode.

2 Click on the button : the traces with marker are listed as well as the option All.

3 Select All to erase all the markers or select one or several traces to erase the corresponding marker.

Adding markers If the markers have not been automatically positioned, to place a marker manually:

– click on the button to access the marker mode (or select Calculation >Marker mode)

– click on the button , – Select the marker you want in the list and click on OK.– Move the cursor to the required position and click.

MeasurementsWhen a trace is opened, measurements are automatically made in the selected mode each time a marker is placed, moved or removed.

The mode of measurement is selected in the Calculation > Measure-ment mode ... :

– Normal: Measurement on the link from one end.

FiberCable Manual 7OFSMAN12/05 111

Page 134: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 8 Analyzing CD tracesMeasurements

– Section: Measurement on a section of the link, using two acquisi-tions from one end of the link, up to each extremity of the section.

– Bidirectional: Measurement on the link using two acquisitions one from each extremity of the link.

CD measurement on a section

To measure the CD on a section of link, this section must be limited by specific events (reflective events or Fresnel) like connectors.

If the section is limited by the events X and Y, two acquisitions are made from the origin of the link:

– one up to the event Y.– the other to the event X (reference).

The process to mesure CD on a section is:

1 Load the trace having the complete CD results, up to the Y event.

2 In the menu Calculation > Measurement mode ..., select Section.

3 In the menu File, select Open reference file ... : find the file and open it.

Then, the table gives results of the section of fiber.

The reference value for every OTDR trace is given on the right of the trace.

Fig. 53 CD measure on one fiber section

O X Y E

Acquisition 2

Acquisition 1

Section of fiber under test

NOTEThe different measurements must be performed with strictly the same module.

112 FiberCable Manual 7OFSMAN12/05

Page 135: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 8 Analyzing CD tracesResults Table

Bi-directional measurement

In order to measure a long link which cannot be entirely measured from one end, a bidirectional measurement shall be used if the link has an event (reflective events or Fresnel) which can be detected from both ends.

Then two acquisitions are made, one from the origin up to X, the other from the end up to X. Both results are added to give the global results of the link.

The process to measure CD on a section is:

1 Open the traces acquired from each extremity of the fiber.

2 In the menu Calculation select: Measurement mode > Bidirectional

Then, the table gives the results of the whole fiber.

The reference value for every OTDR trace is given on the right of the trace.

Results TableWhenever you make a measurement a results table is generated.

Results Table display

To display / hide the table, click on the button or select Results Table from the Display menu.

Fig. 54 Bi-directional measurement

O Y E

Acquisition 1 Acquisition 2

NOTEFor this measurement both acquisitions must be performed with the same CD module.

FiberCable Manual 7OFSMAN12/05 113

Page 136: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 8 Analyzing CD tracesResults Table

Table contents The results table shows for every wavelength: the delay, the dispersion and the slope. This table is interactive and shows the measurement in progress. Any operation on the trace is immediately entered in the table.

If the alarm thresholds are validated in the menu Calculation / Calcula-tion parameters ... a message, above the table, gives the global result with respect to the threshold.

Link between the trace and the table

If you click on a line in the table, it is highlighted and, on the Dispersion, Slope or Delay trace, the cursor A moves to the corresponding position and vice versa.

Saving results After a trace analysis, the results can be saved in a text file format in order to integrate them in a report or in a spreadsheet to make statis-tical analysis.

Use the following steps to save your results:

Fig. 55 Results table

Icons Description

(green) The analysis didn’t find any out of range results.

The analysis has found at least one out of range result.

Out of range result.

Out of range result

Results of the analysis with respect to the chosen alarm thresholds

114 FiberCable Manual 7OFSMAN12/05

Page 137: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 8 Analyzing CD tracesResults Table

1 Select Save Results... from the File menu.The Save as ... dialog box then appears.

2 Select the folder in which the file will be saved.

3 Enter the name of the file: by default, a .txt is proposed. However, you can enter a filename extension corresponding to your spread-sheet (for example, .xls).

4 Click the Save button.

Results file contents

The file contains the following results.

File and measurement identifications:– File name,– Title, acquisition date and time,– Device and module used (type and serial number),– Cable and fiber identification, reflective fiber index,– Approx. formula used,– Length of the tested fiber,– Reference wavelength,– Origin and End identification,– Way,– Comment.

For each wavelength: – delay, dispersion and slope values.

FiberCable Manual 7OFSMAN12/05 115

Page 138: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 8 Analyzing CD tracesResults Table

116 FiberCable Manual 7OFSMAN12/05

Page 139: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 9 Analyzing ATS traces (Spectral Attenuation)

9

This chapter describres how to analyze ATS (Spectral Attenuation) measurements acquired with a JDSU Platform 6000/8000.

Topics discussed in this chapter are as follow :

– “Trace display” page 118– “Defining calculation parameters” page 119– “Results table” page 121

FiberCable Manual 7OFSMAN12/05 117

Page 140: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 9 Analyzing ATS traces (Spectral Attenuation)Trace display

Trace display

Trace display The display window of an ATS file shows the trace parameters, the trace, the position of the cursors A and B and the results table (if selected).

Fig. 56 Spectral Attenuation display

Trace parameters

Position of the cursors

Color selector of the trace

Cursor mode (A / B / Auto)

Small trace

Results table

NOTEThe results table is printed in two columns (click on Print Preview).

118 FiberCable Manual 7OFSMAN12/05

Page 141: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 9 Analyzing ATS traces (Spectral Attenuation)Defining calculation parameters

Cursors position indicator

The status bar, at the bottom of the trace, gives the values of the cursors A and B.

Defining calculation parameters Before performing measurements, you can define specific parameters you want to use.

To modify the calculation parameters, select Calculations parame-ters … in the Calculation menu. The calculation parameters dialog box is displayed.

1 Left click on the Default button to select the default values or enter the required values for:

– Increment: wavelength increment between two results saved in the results table (from 0.1 nm)

Fig. 57 Values of the cursors A and B

Cursors Values

Cursor A - Wavelength of the cursor A (nm).- Attenuation of the cursor A

Cursor B - Wavelength of the cursor B (nm).- Attenuation of the cursor B

Cursor B - A - Wavelength difference between the cur-sors A and B (nm).- Attenuation between the cursors A and B

NOTEThe wavelength difference result is negative if the cursor A is posi-tioned after cursor B.

FiberCable Manual 7OFSMAN12/05 119

Page 142: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 9 Analyzing ATS traces (Spectral Attenuation)Defining calculation parameters

– Wavelength level:– Full band: results are displayed for the entire wavelength

range.– Band C + L: only the results of the C + L band are displayed.– Band S + C + L: only the results of the S + C + L band are

displayed.– Manual band: the displayed band is defined by two wave-

lengths, entered by the user; the starting wavelength (Min.) and the ending one (Max).

2 Notch the Normalized value to display the normalized values, to one kilometer, for each attenuation profile (result is calculated according to the fiber length and the total attenuation).See"Setting Display Preferences" page 50

3 Left click on the OK button to validate the values and to go back to the trace display.orClick on the Cancel button to return to the trace, without having validate the new parameters.

Fig. 58 Calculation Parameters

120 FiberCable Manual 7OFSMAN12/05

Page 143: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 9 Analyzing ATS traces (Spectral Attenuation)Results table

Results tableA results table is provided for each increment step.

Displaying the results table

To display / hide the table results left click on the icon or select Results Table in the Display menu.

Table contents For each wavelength, the table displays the frequency (nm), the Spec-tral Attenuation (dB/km) and the total loss (dB).

Saving results After a trace analysis, the results can be saved in a text file format in order to integrate them in a report or in a spreadsheet file.

Use the following steps to save your results:

1 Select Save results... in the File menu.The Save as... dialog box then appears.

2 Select the folder in which the file will be saved.

3 Enter the name of the file: by default, a .txt is proposed. However, you can enter a filename extension corresponding to your spreadsheet (’for example .xls).

4 Click the Save button.

Fig. 59 Results Table

FiberCable Manual 7OFSMAN12/05 121

Page 144: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 9 Analyzing ATS traces (Spectral Attenuation)Results table

Results file contents

File and measurement identification :– File name– Title, acquisition date and time,– Device and module used (type and serial number),– Cable and fiber identification, reflective fiber index– Wavelength used– Length of the tested fiber,– Average acquisition,– Origin and End identification,– Way,– Comment

For each wavelength : – Spectral Attenuation (dB/km) and total loss (dB).

122 FiberCable Manual 7OFSMAN12/05

Page 145: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 10 Analyzing OFI module results

10

This chapter describes how to analyze one or several FOX measure-ments acquired with a JDSU Platform 6000/8000.

Topics discussed in this chapter are as follow :

– “Results display” page 124– “Setting the alarm parameters” page 125– “Saving results in a txt file” page 126

FiberCable Manual 7OFSMAN12/05 123

Page 146: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 10 Analyzing OFI module resultsResults display

Results display

Opening fox files Once a fox result has been acquired with a 8000 Platform, you can display it using the FiberCable software and work on it or print the results on paper or in pdf format.

In the File menu, the user can open one single OFI result or multiple ones at the same time:

1 Go to File > Open or click on the icon

2 Select the ".fox" file format .

3 Select the file or list of files to load

4 Click on Open if you have selected one single result or Open in the same window if you have selected multiple ones.

Results display Once the file(s) is / are open, the screen displays global information and, according to the selection, detailed results on the right.

Fig. 60 Fox results

Global fiber results with average loss and worst ORL per wavelength

Detailed fiber infor-mation according to the fiber selec-tion: OE - EO; refe-rences etc.

List of fiber results.

124 FiberCable Manual 7OFSMAN12/05

Page 147: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 10 Analyzing OFI module resultsSetting the alarm parameters

Fiber Information Once the fox file is opened, you can display and modify the fiber infor-mation.

1 Select the fiber you wish (if several results have been opened in the same window).

2 Double click on the fiber you want to display the informationA dialog box Fiber Information is displayed

You can change the data, if they are on a white background: fiber iden-tification / Fiber number / Fiber Color.

Setting the alarm parametersYou can choose to activate or disactivate the alarms on the reuslts displayed.

Go in Display > Alarm threshold...

Notch Active to activate the alarms on the fox results displayed.

If the results are above the alarm threshold maximal value, the icon is displayed next to the result concerned.

Fig. 61 Fiber information

Fig. 62 Alarm thresholds parameters

FiberCable Manual 7OFSMAN12/05 125

Page 148: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 10 Analyzing OFI module resultsSaving results in a txt file

To hide this icon, un-notch Active.

Saving results in a txt fileThe file result can be saved in two different txt format:

– the results can be saved in a txt format, to have a summary of the measurement results.

– the results can be saved in a text format in order to generate a cable report using FiberBudget.

Saving results in a txt format

Once the «.fox» file is opened:

1 Click on File > Save results...

2 Select the directory in which the file will be saved.

3 Enter a name for the txt file

4 Click on Save

Saving results in a txt file for Fiber

Budget

If you want ot generate a cable report using FiberBudget, you will have to save results in a compatible txt format:

Once the FOX results are displayed:

1 Click on File > Save as...

2 Select the directory in which the txt file will be save

3 If necessary, change the file name

4 In the list «Type», select OFI: FiberBudget-OFI2000 File (*.txt)

5 Click on Save

NOTEIf the alarm thresholds are active, the alarms will be displayed in the printed version, and represented by the icon .

126 FiberCable Manual 7OFSMAN12/05

Page 149: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 11 Macros

11

You can create macros to automate repetitive analysis tasks on OTDR traces having similar characteristics. This is very useful when you want to quickly make the same measurement or analysis on a group of files and then save or print the results.

Topics discussed in this chapter are as follows:

– “Macro principle” page 128– “Recording a Macro” page 128– “Executing a Macro” page 129

FiberCable Manual 7OFSMAN12/05 127

Page 150: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 11 MacrosMacro principle

Macro principle

Creating a macro involves:– selecting the macro recording mode, – opening the file to use to make measurements you want to record, – saving the results or printing the file. – recording the macro– close the trace to stop recording, – saved the macro in a file for later execution.

Executing a macro on trace file(s) involves:– selecting the macro– selecting the trace files you want the macro to be executed on..

Recording a MacroUse the following procedure to record a macro file:

1 Open the FiberCable software.An empty window is displayed.

2 Click on or select Save series of actions from the Macro menu. You enter in the macro mode: the icon will be displayed at the end of the tool bar during the macro recording.

3 Open the trace on which the macro will be recorded.

4 Carry out the required measurements on the trace. If you modify a parameter of this trace, the modification will be saved on the Macro.

NOTEThe Macro function can only be applied to OTDR traces.

128 FiberCable Manual 7OFSMAN12/05

Page 151: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 11 MacrosExecuting a Macro

5 Depending on the final result you require, you must insert in the macro at least one of these actions from the File menu: Print, Save or Save Results.Actions are not really carried out but their function is recorded in the macro.

6 Select Close from the File menu to close the trace.You are asked if you want to save the series of actions you have just defined. If you associate a macro to a file without executing an output (Print or Save) a message informs you.

7 Click on the Yes button,

8 In the resulting Save as... dialog box, enter the macro file name with the extension .seq and its location. Then click on the OK button.

Executing a MacroUse the following procedure to execute a Macro you have created:

1 Click on the button or select Execute the resulting macro ... from the Macro menu. The following dialog box is displayed.

2 Click on the Select macro ... button and in the Open box select the Macro file to use.

3 Click on the Open button to return to the Series of actions box.

4 Click on the Select traces ... button. The Associate files to this series dialog box opens.

FiberCable Manual 7OFSMAN12/05 129

Page 152: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 11 MacrosExecuting a Macro

5 Select the trace files you want to associate to the macro in the upper window and click on the Add button. To help you in the selection of the files the bottom window gives the parameters of the file selected in the upper window.

6 Click on the OK button to return to the Series of actions dialog box. The macro selected and the files associated are listed.

Fig. 63 Series to associate dialog box

130 FiberCable Manual 7OFSMAN12/05

Page 153: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 11 MacrosExecuting a Macro

7 Either, if you don’t want to execute the macro, click on the Cancel button or if you want to start the macro, click on the Execute button. A box shows the execution in progress and display the trace the macro is executing.

Once the macro has completed, the empty trace window is displayed: you can continue your trace analysis session.

Fig. 64 Macro content dialog box

FiberCable Manual 7OFSMAN12/05 131

Page 154: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 11 MacrosExecuting a Macro

132 FiberCable Manual 7OFSMAN12/05

Page 155: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement Report

12

FiberCable provides a powerful report generation function to ensure the efficient analysis of potential problems for cables.

A cable report is carried out using OTDR, PMD and/or CD measure-ments made on the fibers of the cable by a JDSU MTSe fitted out with an OTDR, PMD and/or CD module.

The report is generated in an ASCII tabulation delimited format, compatible with the majority of Spreadsheet programs on the market (Microsoft Exce, Lotus 123, ….).

Topics discussed in this chapter are as follows:

– “Measurement Report Methodology” page 134– “Measurement Report pProcess” page 135– “Selecting traces” page 136– “Selecting parameters” page 147– “Previewing the report” page 156– “Generating the measurement report” page 157– “Post Processing the measurement report” page 158

FiberCable Manual 7OFSMAN12/05 133

Page 156: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportMeasurement Report Methodology

Measurement Report MethodologyUsing FiberCable to generate measurement reports for fiber optic cables requires a specific test methodology:

1- Measurements in the field using a JDSU MTSe

The first step consists in doing measurements for each of the fibers of the cable for which you want to generate a report, at the different wavelength (in order to detect fiber bending effects). It can be OTDR measurements in both directions, PMD measurements and Chromatic Dispersion measurements.

The acquired traces are stored on the measurement device.

2- Report generation and post processing in the office

All the trace files must be transferred on the hard disk of the office computer equipped with FiberCable and a spreadsheet program such as Microsoft Excel.

– FiberCable is used to generate the report for the cable. – This report can be post processed using the spreadsheet program

before printing. – If Microsoft Excel is available, the macro delivered with FiberCable

can setup, format and print the report.

Requisites In order to use the FiberCable Measurement Report function you must first have certain specific measurement data available on the computer where FiberCable is installed:

– In distinct directories, sets of result files corresponding to OTDR traces (measurements in both directions for all the fibers of the cable), PMD traces, CD traces.

– The OTDR measurement conditions (instrument type, wavelength and pulsewidth) and the deviation thresholds on distance and attenuation.

– The list of fibers of the cable.– The fiber to be used as a standard reference for the other fibers in

the cable.– The required alarm thresholds to be used for the report.

134 FiberCable Manual 7OFSMAN12/05

Page 157: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportMeasurement Report pProcess

Measurement Report pProcessThe successive steps required to generate a report are the followings:

1 Move the files from the MTSe to the PC via a media available (Ethernet, USB, CD etc.).

2 Select the traces to include in the report (OTDR, PMD and/or CD) after selection of the corresponding tab: see “Selecting traces” page 136.

3 Select the measurements parameters: according to the measure-ment selected (OTDR, PMD or CD), the menu Report or the button

will give access to the OTDR parameters, PMD parameters or CD parameters option (see “OTDR parameters” page 149, “PMD parameters” page 154, “CD parameters” page 155)

4 Preview the report under the Preview tab: see “Previewing the report” page 156.

5 Generate the report using the button or the Menu Report > Generate a measurement report. The report has then a text format.

6 To process this report using the Excel spreadsheet program, click on the button or select the Report > Execute the command: FiberCableMacro.xls ... See “Post Processing the measurement report” page 158.

FiberCable Manual 7OFSMAN12/05 135

Page 158: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting traces

Selecting tracesClick on the button to select the directory where are stored the trace files acquired on the cable concerning the report.

Tooltips If you want to display messages describing the commands when the cursor go over them, in the Report menu, notch the Tooltips option.

The files displayed in the file selection list correspond to those that match the defined acquisition characteristics.

It is then possible to make a first selection of files to analyze and sort them, then to notch among the selection those to put in the report.

Fig. 65 Selecting the traces concerning the Report

Trace Directory Selection

Selected filesButtons for partial or total transfer

Tabs selecting the measurement (OTDR, PMD or CD) or the report preview

Content of the selected directory

Shortcuts for main actions

136 FiberCable Manual 7OFSMAN12/05

Page 159: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting traces

Selection of files – To select a specific file click on the file name.– To select multiple adjacent files click on the first file name, press

and hold the SHIFT key and click on the last filename you wish to select. All the files between the first and last files are selected.

– To select multiple non adjacent files, click on the first file name, press and hold the CTRL key and click on the other file names you wish to select: they are highlighted.

Transfer of files in the selection list

To transfer all the files in the selection list:– Click on the select all button to transfer all the files in the

selection list.– To remove all the selected files, press the deselect all button.

To transfer some files in the selection list:– Select one or more files in the Trace Directory and click on the

transfer button .– Select any files in the selected list you do not want to include in

the report and click on the deselect button .

Fig. 66 Trace Directory File Selection

Transfer only the selected files

Transfer all files

NOTEIf you open write protected files, they display in red, are preceeded by the icon and cannot be used to generate a measurement report (buttons are inactive).

FiberCable Manual 7OFSMAN12/05 137

Page 160: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting traces

Selection List The OTDR files transferred to the selection list are automatically sorted by fiber; the same wavelength, the same cable and the same fiber in both directions.

Whenever one or several files are added or removed from the list, all the files are analyzed in order to correctly sort them and detect major incoherences in the measurements. The results of this analysis are detailed fiber1 by fiber with an icon and explanation text in the State column.

Icon list and their meanings

1. For OTDR measurement, fiber refers to the two or four trace files of the same wave-length, the same pulsewidth, the same cable and the same fiber measured from both ends.

The fiber has been selected for processing.

The pre-analysis has been interrupted.

One of the two OTDR trace files of the fiber is missing: either the O −> E or the O <− E one.

Three of the four OTDR trace files of the fiber are missing (middle point measurement).

Two of the four OTDR trace files of the fiber is missing (middle point measurement).

One of the four OTDR trace files of the fiber is missing (middle point measurement)

Read error on one of the two (or four) OTDR trace files.

Different number of events for the O −> E and O <− E files.

Number of results different for the O −> E and O<− E files

O -> E and O <− E OTDR files are not compatible.

Too large distance between OTDR file markers O ->E and E -> O for the same event.

Distance spacing for a same extremity event, between O -> E and E -> O OTDR traces, too large: check the launch cable position. For the other events see the previous icon.

(green) Pre-analysis OK.

(yellow) At least one threshold has been passed *

?

138 FiberCable Manual 7OFSMAN12/05

Page 161: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting traces

* Icons used only in the report preview.

To expand the selection list

to expand the selection list in order to improve the reading click on the button (tool bar) or select the menu Report > Expand the selection

pane.

Available commands All the possible actions on the selected files are listed either in the Report menu or in the contextual menu displayed if you right click in selected file list. Buttons give a quick access to the main actions.

The actions are described below and the direct access buttons are indicated when available.

At least one result is missing for this fiber *

Launch cable correct *

Connector: green= result correct; red= the threshold is passed *

OTDR, PMD or CD parametersOpens the dialog box allowing you to set the measurement parameters (Refer to “Selecting parameters” page 147).

Open files for the fiber selected Open the trace(s) for the fiber selected (four traces if OTDR measurement with middle point). Refer to “Opening the trace(s) for a fiber” page 141. This command is equivalent to a double click on the fiber name in the Selection list.

Bookmark all the fibers – The menu command marks all the fibers in the displayed

selection list (OTDR, PMD or CD)– The button command displays a box to select on what selec-

tion list (OTDR, PMD and/or CD) you want to mark all the fibers.

Bookmark the selectionMark any traces highlighted in the displayed selection list.a

Remove the selected bookmarksDeselect any marked traces highlighted in the displayed selec-tion list.b

FiberCable Manual 7OFSMAN12/05 139

Page 162: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting traces

Remove all the bookmarksDeselect all marked traces in the selection list (OTDR, PMD or CD) .b

Set the current fiber as measurement sourceThe highlighted OTDR trace in the selection list become the ref-erence (See “Set the current fiber as measurement source” page 140)

Remove the measurement reference sourceDeselects any trace that was previously checked to be the measurement source.

Preview the fibers bookmarkedAllows you to preview the data for each checked fiber that will be used in the measurement report (Refer to “Previewing book-marked fibers (step by step)” page 157).

Preview the fibers bookmarked (step by step)Allows you to preview the data for each checked fiber used in the measurement report on a step by step basis (Refer to “Pre-viewing bookmarked fibers (step by step)” page 157).Before the preview data is displayed, the trace files for each fiber are sequentially displayed to allow you to make modifications.

Generate a measurement reportAllows you to generate the measurement report of all the checked fibers and store the data into an ASCII file (Refer to “Generating the report” page 158).

Generate a measurement report (step by step)Allows you to generate the report on a step by step basis and store the data into an ASCII file (Refer to “Generating the report (step by step)” page 158). Before the report is saved the traces for each fiber are sequentially displayed to allow you to make modifications.

Execute command: FiberCableMacro.xlsOpen the FiberCable macro.

Print the fiber bookmarkedPrintout the bi-directionnal analysis for the fibers bookmarked. The layout will be that assigned to the first bookmarked fiber.

a. This can also be done by checking the boxes in the Selection list.b. This can also be done by unchecking the boxes in the Selection list.

140 FiberCable Manual 7OFSMAN12/05

Page 163: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting traces

Opening the trace(s) for a fiber

To open both trace and the event result table of a file, in the selection list, double click on the name of the fiber. You can also choose the fiber, then select the menu Report > Open files for the fiber selected.

For the OTDR measurement, both traces (O −> E and O <− E) of the selected fiber are displayed in the same window. The O <− E trace is inverted in the X and Y axes (depending on the options chosen in the Preferences menu) so that the events correspond on both traces.

The result table can be opened by a click on the button or by the Display > Event table menu.

Use the standard FiberCable commands to process the traces.

In the case of a four OTDR trace with

middle point

To have the configuration of the measurement with middle point, see “Measurement setup” page 149.

Fig. 67 Traces for a fiber (OTDR measurement)

Status of the fiber as it is in the selection list of the report. (refreshed at each action).

FiberCable Manual 7OFSMAN12/05 141

Page 164: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting traces

Measurement with middle point enables to measure a long fiber even if the range of the OTDR is not sufficient. Four acquisitions are carried out: one acquisition in both directions from the middle point of the fiber, then the fiber being closed, an acquisition from both extremities of the fiber. The result is four traces for one fiber.

On the display, in order to get the complete OTDR traces, the useless parts of traces 3 and 4 are cut out and:

– the trace 2 is positioned after the trace 3 to restore the O -> E trace.

– the trace 1 is positioned after the trace 4 to restore the E -> O trace.

If one of the traces is not displayed (trace 1 for ex.), the associated trace 4 is not cut but entirely displayed.

Fig. 68 OTDR Measurement with middle point principle

O EPMAcquisition 1 -> Trace 1 Acquisition 2 -> Trace 2Fiber with

OTDR on the middle point

Fiber closed at the middle point O E

Acquisition 3 -> Trace 3

EAcquisition 4 -> Trace 4

0

O E

O E

NOTE

In the mode with middle point, as there are two O-> E traces and two E -> O traces, the Origin and End parameters must have been entered for every four acquisition, for they are used to define the association of traces.

142 FiberCable Manual 7OFSMAN12/05

Page 165: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting traces

The four traces are identified by their color.

Bookmarking the files

Select one or several fibers in the Selection List and select the menu Report > Bookmark the selection. You can also:

– bookmark the fibers (step by step) notching their case in the Status column.

– or click on the button to bookmark all the fibers in the list.

Printing the traces from the Report

list

In the report list, you can print the traces corresponding to the fibers selected, on paper or in pdf format:

– notch the fibers case in the status column or click on the button to bookmark all the fibers in the list.

– Click on File > Print... or on the button

Fig. 69 Display of the four OTDR traces of a measurement with middle point.

O -> E trace

E -> O trace

PM -> E trace

PM -> O trace

FiberCable Manual 7OFSMAN12/05 143

Page 166: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting traces

The trace corresponding to the first fiber bookmarked opens– Click on Execute

The Printing dialog box open– If necessary, change the printer configuration– Click on OK to start printing

If a pdf printer has been selected, a dialog box opens: choose the directory where the file will be saved and modify the file name if necessary.

Saving report status information

in a txt or xls file

The Report Status Information can be generate in a txt. or xls format from the main menu.

Once the files are transfered in the report list:

– Select the fibers to be included in the txt / xls file.

– Right click and select Save Summary... or select the menu File > Save Summary...

– The dialog box opens and allows to save the Report status Infor-mation in a txt file.

NOTEFor a pdf format, a PDF writer software is mandatory (Adobe Acro-bat, PDFCreator, Cuteprinter...)

With the pdf format, the files selected in the report list will be printed in batch, in one single file.

NOTEIf all the fibers are unselected, the txt file will contains all the fibers by default.

144 FiberCable Manual 7OFSMAN12/05

Page 167: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting traces

The txt file contains all the details of the report files selected for a summary.

The first part is a list of the file, as shown in the report list in the OFS 200.

Then, the file displays a detailed description of each fiber, with the following parameters: File name / Pulse / Wavelength / Range / Reso-lution / Acquisition Time / Average / Date / Time / Device / OTDR number / Module / Module number / Type / Last event / Total Loss / ORL / Index / Backscatter coefficient.

Fig. 70 Selection of the Save Summary...key

Fig. 71 Report Status information with detailed parameters (txt file)

Status Information

Detailed parameters

NOTEThis function is only available with the OTDR module.

FiberCable Manual 7OFSMAN12/05 145

Page 168: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting traces

Allocating a reference fiber to

the other fibers of the cable

A fiber can serve as a measurement reference for the measurements on the other fibers of the cable. The reference fiber must contain markers.

Use the following procedure to define the reference fiber and apply its measurement conditions to others fibers of the cable.

OTDR reference 1 Double click on the fiber you wish to use as the reference fiber for your report. You can also choose the fiber and select the menu Report > Open files for the fiber selected. The traces corresponding to measurements made from both ends are displayed in the same window. The Return Trace is inverted in the X and Y axes (depending on the inversion options chosen in the Preferences menu) so that the markers of the same event on each trace correspond on both traces.

2 Select the location of launch cables (see “Measurement setup” page 149)

3 Adjust the position of event markers on the active trace (O −> E) and/or, if necessary, make manual measurements.

4 Shift the traces as required

5 Click on the radio button of the Trace Parameters window of the reference trace (O← E) to make it the active trace.

6 Adjust the position of the markers on this trace.

7 Select the Close option from the File menu. Save the modifications to each trace (O→E and O←E) when prompted to do so.

8 In the Selection List select one or more fibers in order to apply them to the measurement parameters of the reference fiber.Click on the button or select the menu Report > Bookmark the selection to mark these fibers. You can also select the fibers indi-vidually by checking the box in the State column.

9 Select the fiber you wish to use as the measurement reference source.

10 Click on the button (or select the menu Report > Select the current fiber as measurement source).

146 FiberCable Manual 7OFSMAN12/05

Page 169: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting parameters

PMD or CD reference 1 Double click on the fiber you have selected as reference to display its traces (you can also select the fiber then the menu Report > Open files for the fiber selected).

2 In the Selection List, select the fiber(s) to which you wish to apply the conditions of measurement of the reference fiber; click on the

button (or select the menu Report > Bookmark the selection). You can also mark fibers individually by notching their box in the State column.

3 Select the fiber previously defined as reference of measurement.

4 Click on the button (or select the menu Report > Set the current fiber as measurement source).

Selecting parametersFor the generation of your report you have to define cable parameters and specific OTDR, PMD and CD measurement parameters. Different tabs give access to each type of measurement and to the report preview.

Cable Information Select the menu Report > Information Cable... or click on the and enter additional information on cable and fiber (manufacturer and type), and the manager and technician names.

– Click on the Erase button to delete all the informations entered since the dialog box has been opened.

– Click on the Cancel button to delete the entered informations and close the dialog box.

– Click on the OK button to save the entered informations and close the dialog box.

NOTEAfter either a preview, or the generation of the report, or a display of the trace, the data of the reference source are copied in the destina-tion files and the link with the reference is removed.

FiberCable Manual 7OFSMAN12/05 147

Page 170: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting parameters

You can also choose to customize the cable / job information.

– Notch the box User defined labels.– Notch Copy on all fibers if you want to apply the cable informa-

tion on the entire cable. If un-notched, the original cable informa-tion will be kept.

– In the left column, enter the type of information (labels) to be displayed.

– In the right columns, enter the corresponding data for each label.

Click on Clear to delete all the information

Fig. 72 Cable parameters by default

NOTEAll the labels will be saved and re-used for each OTDR trace. Moreover, they will be displayed in the printed report.

Fig. 73 Customized cable information

148 FiberCable Manual 7OFSMAN12/05

Page 171: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting parameters

Access to Report parameters

According to the type of measurement you are setting up (OTDR, PMD or CD) the Report menu or the button opens the OTDR, PMD or CD Parameters dialog box.

OTDR parameters The OTDR tab being selected, choose the menu Report > OTDR Parameters or click on the button . The OTDR Parameters dialog box displays.

Measurement setup Select the Measurement setup tab:

1 Select the number of launch cable (0 to 3) at the start and at the end of the fiber under test by clicking on the corresponding radio buttons.

2 Select the type of measurement:– Traditional: for one fiber, one measurement in both directions,

therefore two trace files. – Loop measurement: two fibers are looped at one extremity, while

the acquisition is carried out at the other end. The result is two trace files for the two fibers. The loop parameters are defined under the Loop tab (see below).

– Measurement with Middle point: For the very long links, this type of measurement enables the artificial increase of the range (up to double). This means that for one fiber, four acquisitions can be carried out: one acquisition in both directions from the middle point of the fiber, then, after closing the fiber at the middle point, an acquisition from both extremities of the fiber. The result is four trace files for one fiber. The middle parameters are defined under the Middle point tab (see “Middle point” page 152).

FiberCable Manual 7OFSMAN12/05 149

Page 172: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting parameters

3 If you do not wish to include in the report certain results linked to fiber launch cables, then activate the appropriate check box.

The Default button enables the automatic selection of: one launch cable at the start, one launch cable at the end, a classical measure-ment, removal of launch cable values.

Loop Under the Loop tab, define the loop configuration and how the acqui-sition is performed.

The dialog box remains inactive if a loop measurement type is not selected.

Fig. 74 OTDR Parameters Dialog Box

Delete launch cable values from report

Remove the slope values and the results linked to launch cables. With a loop measurement, this removal is done auto-matically.

Delete connector values of launch cable from report

Remove the results linked to the connec-tors situated between the launch cable and the measured fiber.

150 FiberCable Manual 7OFSMAN12/05

Page 173: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting parameters

– Choose one of the Number of looping reels radio buttons:– 0 if the loop is done with an adapter, a splice or a jumper the

OTDR will not measure (one reflectance peak).– 1 to 3 if the loop is done by one or more reels.

– Choose the Method of numbering the measurement direction and then the Method of numbering the fiber:

Fig. 75 Loop parameters

All the acquisitions are done in the direction 0 -> E (acquisition from the origin). The fiber number is incremented by +1 for each OTDR acquisition. Sequence: n, n+1, n+2, n+3, etc.

All the acquisitions are done in the direction E -> 0 (acquisition from the extremity). The fiber number is incremented by +1 for each OTDR acquisition, Sequence: n, n+1, n+2, n+3, etc.

The fiber number of the E -> O trace corresponds to the fiber number of the O -> E trace. To and Return Traces being on the same fiber number, the sequence is: n, n, n+2, n+2, etc.

FiberCable Manual 7OFSMAN12/05 151

Page 174: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting parameters

This last sequence is not recommended: it is only available for compa-tibility reasons with previous FiberCable versions.

– The Default button allows for the automatic selection of one looping reel and the sequence O -> E.

– Click on OK to save the chosen parameters.

Middle point The Middle point dialog box is inactive if the middle point measurement is not selected.

Middle point measurement process:

1 Choose the number of launch cables at the middle point, for both directions of the measurement (0 to 3).

2 Choose the Middle point localization mode:– Automatic: the middle point location is deducted from the

results obtained from the four OTDR traces.– Distance Origin-MP: the middle point location is calculated from

detected events in the direction E --> O. It is associated with the event closest to the entered value in the corresponding field.

– Event number (O--> E): the middle point location is calculated from detected events in the direction O --> E. It is associated with the event whose number is entered in the corresponding field.

Fig. 76 Middle point parameters

152 FiberCable Manual 7OFSMAN12/05

Page 175: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting parameters

3 The Default button allows for the automatic selection of: 1 launch cable at middle point in each direction and automatic localization.

4 Click on OK to save the chosen parameters.

Other Select the Other tab.

1 Select the parameters which will be used for the report preparation but will not be included:

– Enter the Distance spacing tolerance: the max. distance between the corresponding markers to the same event, on the two traces O->E and E->O. When this value is exceeded, a message is displayed in the selected trace list.

– Select Alarm on negative values if you wish to have a message when the result is negative for an event. This message is displayed in the report preview.

2 Enter the Loss difference threshold between wavelengths to use in the report. This threshold corresponds to the max. difference for an event between the measurement results to the wavelengths.

3 The Default allows for the automatic selection of the tolerance (5%), the alarm on negative values, the threshold loss difference between wavelengths: 0,5 dB

4 Click on OK to save the selected parameters.

Threshold per wavelength

Select the Thresholds per wavelength tab:

1 The buttons and enable the scrolling of wavelengths.

2 Choose the required threshold values per wavelength.– The first set of values concerns the thresholds relative to the

average between the measurements O --> E and O <-- E for each event of the fibers (in the following table given as an ex: M11, M12, ...M21, M22, etc.).

– The second set of values concerns the thresholds relative to the average between the measurements O -->E and O <-- E for each event of every fiber (in the ex: Me1, Me2, Me3, ...) and for every event of each fiber (in the ex: Mf1, Mf2, Mf3...).

FiberCable Manual 7OFSMAN12/05 153

Page 176: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting parameters

3 Click on the Default button to choose the default threshold.

4 Click on the OK button to save the report parameter information.

PMD parameters Select the PMD tab and click on the button (or menu Report > PMD Parameters).

Alarm thresholds Three options are possible:

– None: no alarm selected. – Predefined: PMD threshold delays are automatically calculated

and adjusted according to the selected bit rate among: OC-1 (2000 ps), OC-3/STM-1 (640 ps), OC-12/STM-4 (160 ps), OC-24 (80 ps), OC-48/STM-16 (40 ps), OC-192 / STM-64 (10 ps), OC-768 / STM-256 (2.5 ps).

– Manuals: thresholds must be entered after notching the corre-sponding parameter: PMD or PMD2 Delay, PMD or PMD2 Coeff.

Coupling – Strong: For classical, long single-mode fibers, – Weak: For polarization-maintained fibers and components.

Fiber length The fiber length must be entered to calculate the PMD coefficient.

Event 1 Event 2 Event 3

Fiber EO OE Average EO OE Average EO OE Average Average

F1 M11 M21 M31 Mf1

F2 M12 M22 M32 Mf2

F3 M13 M23 M33 Mf3

.

.. .

.

.. .

Average Me1 Me2 Me3

154 FiberCable Manual 7OFSMAN12/05

Page 177: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportSelecting parameters

CD parameters Select the CD tab and click on the button (or menu Report > CD Parameters).

Click on the Default button to select the default values, or enter the required values.

Thresholds To enter manually the threshold of the standardized values of disper-sion and slope:

– in the Thresholds field, select the option Manual.

– notch the parameter on which you wish to place a threshold (Dispersion and/or Slope) and enter the threshold in the corre-sponding field.

Approximation method

You can change the delay approximation method used to generate the dispersion and slope traces:

– Quadratic: A+Bλ+Cλ2.

Recommended only for G.653 fiber in the 1550 nm region. – Sellmeier 3-term: A+Bλ2+Cλ-2.

Recommended only for G.652 in the 1310 nm region– Sellmeier 5-term: A+Bλ2+Cλ-2+Dλ4+Eλ-4.

Recommended for all the other cases, even in non homoge-neous fiber links.

Reference wavelength

You can also change the wavelength taken as reference for delay calculation: other wavelength delays are subtracted from this refer-ence delay.

Calculation parameters

You can select the following parameters:

– dispersion results normalized to 1 km (dividing them by the fiber length expressed in km)

– minimum and maximum wavelengths displayed on the trace and in the table (from 1255.0 to 1650.0).

– the number of results listed in the table (1 to 400).– the wavelength increment between two successive results in the

table (from 0.1 nm).

FiberCable Manual 7OFSMAN12/05 155

Page 178: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportPreviewing the report

Click on the OK button to enter the displayed values and go back to the trace display.

Previewing the reportBefore generating your report you can preview the traces to ensure that the correct data will be generated. There are two methods of previewing the files:

– either preview all the marked fibers directly.– or (for OTDR measurement only) preview the marked fibers on a

step by step basis. In this case, pressing the Next button allows to display the successive traces for each selected fiber and, if neces-sary, to modify them.

The data is displayed in the final report format with tabs giving the following data groups:

– General Information– Loss (dB)– Slopes (dB/km)– Reflectance (dB)– Spans (m)– OTDR Alarms (display the out of range values)– PMD– CD

Previewing bookmarked fibers

Click on the Preview tab button to visualize what will be stored in the spreadsheet file of the measurement report.

NOTEYou can directly open the traces of a fiber by a double-click on the corresponding line of the table.

156 FiberCable Manual 7OFSMAN12/05

Page 179: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportGenerating the measurement report

Previewing bookmarked fibers

(step by step)

Use the following procedure to preview the marked files step by step:

1 Select the menu Report > Preview the fibers bookmarked (step by step).

The traces of the first fiber selected in the selection list displays.

OTDR traces for measurements made from both ends are displayed in the same window. The O <− E trace is inverted in X and/or Y so that the events correspond on both traces.

2 Make any modifications you require and click on the Next button to display the traces of the next fiber selected in the selection list.

3 Repeat the above step for each of the fibers marked in the selec-tion list.The Preview window allows you to visualize what will be stored in the spreadsheet file of the measurement report.

4 Press the OK button to close the Preview window and return to the Configure a measurement report window. You can also return to the Configure a measurement window without closing the preview window by clicking anywhere in the Configure a measurement window. To return to the Preview window click anywhere on it.

Generating the measurement reportOnce you have selected all the fibers you want to include in your measurement report and are satisfied with the previewed result you can generate the measurement report.

NOTEThe Previous button allows you to return to the previous fiber. The Stop button stops the preview and returns to the Configure a measurement report dialog box. The Execute button stops the step by step previewing. The preview continues normally.

NOTEGenerating the report is always possible even if the preview window shows errors.

FiberCable Manual 7OFSMAN12/05 157

Page 180: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportPost Processing the measurement report

The Report generation function provides two methods of generating the data:

– either to generate the data for all the fibers directly – or, in step by step mode, open the successive files before saving

the data. In this case, the traces for each of the fibers selected are displayed one after another (using the Next button) to make any necessary modifications before saving the data in the selected spreadsheet file.

Generating the report Use the following procedure to generate the measurement report:

1 Select the menu Report > Generate a measurement report. The Spreadsheet File text box displays.

2 Select the directory where you want to store the generated spreadsheet file.

3 Enter its file name.

4 Select its type:.txt or *.*

5 Click on the Save button.

The measurement report is generated and stored in the spreadsheet file in ASCII tab delimited format.

Generating the report (step by step)

– Use the same procedure as detailed in the previous section but select the menu Report > Generate a measurement report (step by step).

– You can display the traces for each fiber sequentially to make any modifications. Then, the measurement report is generated and stored in the spreadsheet file.

Post Processing the measurement reportAfter you have successfully generated your measurement report you can open the spreadsheet file using a spreadsheet program such as Microsoft Excel to carry out any post processing you require.

You must first, if necessary, convert the file in an Excel format.

158 FiberCable Manual 7OFSMAN12/05

Page 181: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportPost Processing the measurement report

To help you do the conversion as efficiently as possible a special Excel macro file (FiberCableMacro.xls) is delivered with FiberCable, in the FiberCable directory. This file is used to select the user language and the required number of decimal digits, and to setup the pages for printing.

Using the Excel FiberCable Macro

1 Open the macro:– either, from Windows Explorer, by double-clicking on the Fiber-

CableMacro.xls file located in the FiberCable directory. – either, from the Configure measurement report window of Fiber-

Cable, by clicking on the button or in selecting the menu, Report > Execute command: FiberCableMacro.xls ...

The Excel application starts.

2 A macro warning message may appear. In this case select Acti-vate the macros.

3 A second warning message may appear. In this case select OK. The FiberCable box opens:

4 Click on the Configuration button.

NOTETo use this macro a printer must be installed.

Fig. 77 FiberCable Macro box

1- Generate the folder

2- Final printing

Configuration

FiberCable Manual 7OFSMAN12/05 159

Page 182: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportPost Processing the measurement report

5 Under the Configuration tab you can setup the report – the Language (for the user language see “Processing the report

in a user defined language” page 162).– the Paper size (A4, A5, etc.)– the Title of the report– the Logo filename: you can load most of the format accepted by

ExcelTM,– the Number of fibers per page: 1 to 48,– the Number of digits in the results: 1 to 3,– the display of a preview before printing

– the use of the Compact format

6 Under the Results tab, notch the results (OTDR, PMD, CD) to insert in the report:

For OTDR measurements select:– the wavelengths inserted in the report. If only one wavelength

is selected, the comparison is automatically removed from the report.

– It is not possible to select monomode and multimode wave-lengths simultaneously. Thus if a monomode wavelength is selected, the multimode values are not available and vice versa.

– the table of results to print: connector & splice, reflectance, slope, total link loss, out of range values, bi-lambda compari-sons (the macro can deal with more than two wavelengths, so you must select both wavelengths required for the comparison)

– Insertion loss and ORL table– import results coming from the JDSU OFI 2000 tester, via the

Fiber Budget software. Then, at the start of the macro, a window requests to indicate the directory where the OFI results are stored. This function is only possible if one of the boxes Insertion loss table and ORL table is notched.

NOTE

Total link loss table cannot be selected if the Compact format has been selected (under the tab Configuration of this box)

160 FiberCable Manual 7OFSMAN12/05

Page 183: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportPost Processing the measurement report

7 Once the configuration is finished, click on the OK button. The FiberCable box appears again: you must choose between generating the report or printing it.

Opening the FiberCable box

If this FiberCable box is not opened you can display it using one of the two following methods:

1 Click on the button.

2 Select the menu Tools > Macro > Macros ... The Macro dialog box displays: select the Auto_open macro and click the Execute button.

Report format Standard Format

In the standard format, the report includes the following informations:

1 the title

2 the table of contents

3 general information about the link, the cable and the measure-ments

4 a length table of each link section

5 bi-directionnal splice loss tables for each wavelength

6 section loss tables for each wavelength

7 total link loss tables for each wavelength

8 insertion loss tables for each wavelength

9 ORL tables for each wavelength

10 a table giving the results of the comparison between the two selected wavelength.

11 a table of PMD results

12 a table of CD results

13 a table of Out of range OTDR results (for the selected wave-length), PMD and CD results.

Compact Format

In the compact format:

FiberCable Manual 7OFSMAN12/05 161

Page 184: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportPost Processing the measurement report

– length, bi-directionnal splice loss, loss difference (between the two selected wavelengths) and total link loss values, for every wave-length, are put together in the same table.

– for each other parameter (slope, insertion loss, ORL, Out of range) there is only one table including results at every selected wavelength.

Report generation 1 Select the option 1: FiberCable file format.The Open file dialog box is displayed.

2 Select the report file and click Open. The macro formats the report then you are prompted to enter the file name for the report.

3 Enter this filename and click OK. The file is generated and you can analyze it before printing it.

Report printing 1 Select the option “2: Print preview formatted file” (or print formatted file) depending on the configuration selected.The Open file dialog box is displayed.

2 Select the report file and click Open. The macro formats the printing then the report is previewed.

3 Click on the Print tab to print it.

Processing the report in a user

defined language

When the FiberCableMacro.xls has been opened, the button and the FiberCable box are on the screen.

To translate the report text and the menus in your own language, if it is not one of those available:

– Close the FiberCable box.– Expand the button to display the worksheets.– Click on the User worksheet.

NOTEThe process speed is directly linked to the printer driver.

162 FiberCable Manual 7OFSMAN12/05

Page 185: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportPost Processing the measurement report

– Translate in your own language the text displayed in english in the orange field.

Menus and texts of the report will then be in this language.

Others worksheets

The Config. worksheet remind in column 7, the report set-up. For each parameter: Y = parameter in the report, N = parameter out of the report.

In the worksheets Français, English, Deutsch and Espanol it is possible to change the text of the report in the corresponding languages.

The next worksheets show the different parts of the measurement report.

FiberCable Manual 7OFSMAN12/05 163

Page 186: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Chapter 12 Measurement ReportPost Processing the measurement report

164 FiberCable Manual 7OFSMAN12/05

Page 187: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Appendix A Customer Services

A

This chapter describes the customer services available through JDSU.

Topics discussed in this chapter include the following:

– “About our services” page 166– “Customer care” page 166– “Global services and solutions” page 168

FiberCable Manual 7OFSMAN12/05 165

Page 188: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Appendix A Customer ServicesAbout our services

About our servicesJDSU offers an unmatched portfolio of services to deploy, support and innovate purchased equipment through its Customer Care and Global Services and Solutions organizations. Customer Care is standard with every product sale and consists of business hour technical assistance, in-warranty repair, calibration, and upgrade services. Global Services and Solutions provides professional services to optimize product capabilities and maximize efficiencies, including field engineering and deployment, technical training, product support, consulting and cus-tom software development. Together these organizations supply the services necessary successfully utilize purchased equipment.

Customer careCustomer Care is accompanied with the sale of every JDSU product. Customer Care services include:

– Needs Analysis on Products and Services – Comprehensive Product and Service Literature – Pre-Sales Consulting– Technical Assistance (Business Hour)– Instrument Repair (Under Warranty Repair and Calibration

Services) – Immediate Return Authorizations Contact a Customer Care representative through your local distributor or by accessing www.jdsu.com for information on upgrades, calibra-tion, warranty policies or any of Global Services and Solutions offer-ings. Representatives also provide assistance with product repairs and returns.

Technical assistance

(business hour)

Expert business hour technical support, including help with product configuration, circuit qualification, and complete network trouble sec-tionalization is provided with your product (see“Technical assistance” page xviii).

166 FiberCable Manual 7OFSMAN12/05

Page 189: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Appendix A Customer ServicesCustomer care

Warranty information

The warranties described herein shall apply to all commercially avail-able JDSU products. Any additional or different warranties shall apply only if agreed to by JDSU in writing. These warranties are not transfer-able without the express written consent of JDSU.

Software Warranty — JDSU warrants that Software Products licensed to Customer shall, under normal use and service, and for a period of ninety (90) days from the date of shipment of the Software to Licensee (the “Warranty Period”), perform in all material respects in accordance with the published specifications for such Software as established by JDSU. However, JDSU does not warrant that the Software will operate uninterrupted or error free, operate in the combination with other soft-ware, meet Customer’s requirements, or that its use will be uninter-rupted.

JDSU’s obligation and Customer’s sole and exclusive remedy under this Software Warranty is limited to, at JDSU’s option, either (i) correct-ing the material errors reported to JDSU in writing by Customer during the Warranty Period and which JDSU is able to reproduce, (ii) replacing such defective Software, provided that JDSU received written notice of such defect within the Warranty Period, or (iii) provided that JDSU received written notice of such defect within the Warranty Period, ter-minating the License and, upon return to JDSU of the Software, Docu-mentation and all other materials provided by JDSU under the applicable License, providing Customer with a refund of all charges paid with respect thereto. JDSU shall have no warranty obligations hereunder if (a) the Software is altered or modified or is merged with other software by Customer or any third party or (b) all or any part of the Software is installed on any computer equipment other than the Designated Server or used with any operating system for which the Software is not designed.

WARRANTY DISCLAIMER — FOR HARDWARE, SOFTWARE, AND/OR SERVICES FURNISHED BY JDSU, THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTEES AND CONDITIONS, EXPRESS OR IMPLIED. JDSU SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EITHER EXPRESS OR IMPLIED, ON ANY HARDWARE, SOFTWARE, DOC-UMENTATION OR SERVICES INCLUDING BUT NOT LIMITED TO WAR-RANTIES RELATING TO QUALITY, PERFORMANCE, NONINFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICU-LAR PURPOSE, AS WELL AS THOSE ARISING FROM ANY COURSE OF

FiberCable Manual 7OFSMAN12/05 167

Page 190: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Appendix A Customer ServicesGlobal services and solutions

DEALING, USAGE OR TRADE PRACTICE. UNDER NO CIRCUMSTANCES WILL JDSU BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAM-AGES RELATED TO BREACH OF THIS WARRANTY.

Global services and solutionsGlobal Services and Solutions markets a broad portfolio of services to enable customers to aggressively build their competitive advantage within the markets they serve. Global Services and Solutions innova-tive offerings respond to our customers’ dynamic needs:

– System deployment and field engineering services– Technical training– Product support – Consulting– Custom software development – Integrated service programs

Additional information can also be found on our web site under Ser-vices.

168 FiberCable Manual 7OFSMAN12/05

Page 191: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Index

AAP

trace parameters 40

ATScalculation parameters 119cursors 119display preferences 53results 121trace display 118

CCD

alarms 108calculation parameters 107cursors 107display preferences 52markers 110measurement 111

bi-directional 113section 112

OTDR traces 110results 113trace

delay 109dispersion 109slope 109

trace display 106trace parameters 39

Confidence in results 82

ConfigurationMTS-PC 16

ConnectionMTS-PC 17

Cursors 47

Customer services 165

DDisplay

trace only 43

EEthernet

connection 17

FFile

FiberCable Manual 7OFSMAN12/05 169

Page 192: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Index

cascade and tile 54conversion 7navigation 53opening 6opening several files 7

FOXalarm parameters 125display preferences 53fiber information 125file opening 124results display 124results in a txt file 126trace parameters 40

HHardware

requirements 2

MMacro

execute 129principle 128recording 128

Meas. Reportbookmark files 143excel macro 159generating 157, 162methodology 134OTDR parameters 149parameters 147, 149PMD parameters 154post processing 158prevew 156printing 162printing traces 143process 135requisites 134status 144traces selection 136transferring files 137

Mouse pointer 47

OOEO files 79

OTDRboth end measurement 76contribution measurement 73cursor 59defining mask 74differences between traces 75discontinuity measurement 69, 70display preferences 50event 40

automatic detection 61detection criteria 61

grid 41manual measurements 69markers 62

adding 63delete 64hide/display 63mode 62modify 64position 64

markers group 65multi-traces 54

analysis 78ORL measurement 71parameters 60predefined zoom 42reflectance measurement 71results table 80saving results 83slope measurement 69trace display 58trace parameters 37trace shift 44

PPMD

alarms 100cursor 99display preferences 52results 102trace display 98trace parameters 38

Printingmosaic 12, 13multi-traces 12options 9

170 FiberCable Manual 7OFSMAN12/05

Page 193: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Index

RRS 232

connection to the interface 18

SSoftware

installation 2removing from PC 4requirements 2upgrade 4

TTable

alarms 44results 44

Table of resultsconfidence 82

Tracecopy to Word 56information 49menu 35parameters 35removing 56

tool bar 35window 34

WWarranty 167

WDM-OSAalarms 95calculation parameters 87calculations 89channels 92, 93cursors 87differences between traces 95display preferences 51grid 41multi-traces 54overlay trace 95results 92, 94results table 91statistics 93table contents 93trace display 86trace parameters 38vertical shift 46

ZZoom 41

FiberCable Manual 7OFSMAN12/05 171

Page 194: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Index

172 FiberCable Manual 7OFSMAN12/05

Page 195: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05
Page 196: Ofs-200 v4.40 en Nov06- Pn 7ofsman12 Rev05

Test and Measurement Regional Sales

North AmericaToll Free: 1 800 638 2049Tel: +1 240 404 2999Fax:+1 240 404 2195

Latin AmericaTel: +55 11 5503 3800Fax:+55 11 5505 1598

Asia PacificTel: +852 2892 0990Fax:+852 2892 0770

EMEATel: +49 7121 86 2222Fax:+49 7121 86 1222

www.jdsu.com

7OFSMAN12/05Rev.05, 11-06English