Optical Needle Holder Intraluminal repair of posterior tracheal rupture THOR 11 3.1 11/2017-E

Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

Embed Size (px)

Citation preview

Page 1: Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

Optical Needle HolderIntraluminal repair of posterior tracheal rupture

T H O R 1 1 3 . 1 1 1 / 2 0 1 7 - E

Page 2: Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

2

Endotracheal suture of an iatrogenic laceration of the posterior tracheal wall

Trachea rupture is a rare complication of intubation and percutaneous tracheostomy. Early surgical treatment is recommended as iatrogenic injury to the membranous wall may cause severe mediastinal emphysema or mediastinal prolapse as well as other respiratory complications. Complete endotracheal suturing is a new and anatomically friendly method of surgical repair. We developed a new needle holder consisting of a HOPKINS® telescope in a fixed attachment to an endoscopic needle holder. This allows endotracheal suturing of an iatrogenic laceration of the posterior tracheal wall without additional surgical access in an anatomically friendly manner. Patients are thus spared a surgical intervention and associated postoperative pain. There is no scarring and early extubation is possible. Even if prolonged ventilation is necessary, endoluminal suturing can prevent a tube dislocation at the injury site and associated life-threatening respiratory complications.This method is suitable for patients who are able to tolerate jet ventilation during an intervention and where rupture is limited to the trachea.There are some technical limitations to this method: If the tracheal tear has no rim of membranous wall; if the rupture extends into the right main bronchus; and if the patient cannot tolerate jet ventilation due a functional limitation.

PD Dr. Stefan Welter Ruhrlandklinik, Westdeutsches Lungenzentrum

am Universitätsklinikum Essen gGmbH -Universitätsklinik- Tüschener Weg 40

45239 Essen Germany

The QR code provides a 2-minute video1. This shows a tracheal rupture and the use of an optical needle holder.

References

1. Welter S, Darwiche K, Cheufou D, Stamatis G. Management von Komplikationen in der Thoraxchirurgie: Tracheaverletzungen, Insuffizienz von Bronchusstumpf oder -anastomose, Recurrensparese. Chirurg 2015, März 22.DOI 10.1007/s00104-014-2862-3

2. Welter S, Cheufou D, Ehmann T, Kampe S, Scharmann P. Endotracheal Repair of an Iatrogenic Tracheal Laceration in a 83-Year Old Critically Ill Woman with Aspiration Pneumonitis and Sepsis. J AnestheticAnesthesiol 2014,1:3

3. Welter S. Repair of tracheobronchial injuries. Thorac Surg Clin. 2014 Feb; 24(1): 41–50. Review.

4. Welter S, Hoffmann H. Injuries to the tracheo-bronchial tree. Zentralbl Chir. 2013; 138(1): 111–6.

5. Welter S, Krbek T, Halder R, Stamatis G. A new technique for complete intraluminal repair of iatrogenic posterior tracheal lacerations. Interact Cardiovasc ThoracSurg 2011; 12(1): 6–9

6. Welter S, Stamatis G. Reply to the Editor. Intraluminal repair of tracheal membrane rupture. Ann Thoracic Surg 2011; 91:1655

7. Welter S, Jacobs J, Krbek T, Halder R, Stamatis G. A new endoscopic technique for intraluminal repair of posterior tracheal laceration. Ann ThoracSurg 2010; 90(2): 686-8

1 Courtesy of PD Dr. Stefan Welter, Ruhrlandklinik, Essen, Germany

© K

AR

L S

TOR

Z 9

6082

012

THO

R 1

1 3.

1 11

/201

7/E

W-E

Page 3: Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

3

Endoscopic techniquefor the intraluminal repair of a posterior tracheal rupture

In the preparation phase, a clip is applied to the suture loop so that the thread is grasped twice. The first stitch is secured with this clip.

After suturing is complete, the proximal clip is inserted through the tracheoscope under direct visualization. The open clip is guided along the thread until the forceps is positioned dorsal to the membranous wall and the thread is directed caudally. The use of two clips is recommended.

Clips: PDS clip Absolok 100 (Ethicon)

The rigid tracheoscope is visible at the bottom of the image. The tracheal rupture can be seen on the left-hand side and the optical needle holder with needle in the center (2.0 Vicryl UCLX needle, 70 cm; Ethicon) during piercing of the right rim.

The endotracheal suture is performed with a shortened, rigid 14 mm tracheoscope and an optical needle holder. Using a 2/0 Vicryl thread and a UCLX needle (Ethicon), the rim of the ruptured membranous wall is re-adapted under jet ventilation.

This image shows a posterior tracheal rupture after complete intraluminal repair using the endoscopic technique.

After each stitch, it is necessary to suction blood and secretions and to re-align the camera head to restore the horizon line. The thread is held under tension to offset any turbulence caused by jet ventilation.

Information on the OR technique and OR images provided with the kind permission of PD Dr. Stefan Welter, Ruhrlandklinik, Westdeutsches Lungenzentrum, am Universitätsklinikum Essen gGmbH, Universitätsklinik, Tüschener Weg 40, 45239 Essen, Germany.

© K

AR

L S

TOR

Z 9

6082

012

THO

R 1

1 3.

1 11

/201

7/E

W-E

Page 4: Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

4

The newly developed optical needle from KARL STORZ allows the user to perform minimally invasive and safe intraluminal repair of a tracheal rupture under visual control without requiring surgical access. This method is more gentle on the patient than previous methods of tracheal rupture repair.

The new set from KARL STORZ consists of a shortened tracheoscope in size 14 mm and a needle holder with a 4 mm HOPKINS® endoscope.

Features and Properties at a Glance

Tungsten carbide inserts in both jaws ensure a firm and secure hold of the needle while maintaining high material resistance.

The needle holder is used in conjunction with a 4 mm HOPKINS® Endoscope 10105 FA with a direction of view of 12° and a working length of 30 cm. The endoscope provides optimal visualization and thus allows targeted suturing under continuous visual control.

The distal tip features a robust, movable and fixed jaw.

Page 5: Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

5

To use the needle holder, a 14 mm Tracheoscope 10318 GK with a working length of 20 cm is recommended. In contrast to standard tracheoscopes, this shorter tracheoscope offers a greater freedom of movement that simplifies suturing.

The special needle blocker provides safe and precise positioning of the needle in the jaws. The disengageable ratchet mechanism on the handle enables effortless unlocking of the needle blocker at any time.

The ergonomic handle design allows comfortable and precise work. The needle holder is lighter in weight thanks to titanium handles.

Page 6: Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

6

Set from KARL STORZfor the intraluminal suture of a posterior tracheal wall rupture

10130 N Optical Needle Holder, for endoscopic treatment of trachea ruptures, for use with HOPKINS® Telescope 10105 FA

10105 FA HOPKINS® Telescope 12°, diameter 4 mm, length 30 cm, autoclavable, fiber optic light transmission incorporated, color code: black

10318 GK Tracheoscope, size 14, length 20 cm

© K

AR

L S

TOR

Z 9

6082

012

THO

R 1

1 3.

1 11

/201

7/E

W-E

Page 7: Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

7

12067 TR Clip Forceps, applicator for absorbable ligating clips, jaw curved to right, with cleaning connector, working length 30 cm

10367 S Scissors, straight, single action jaws, with cleaning connector, sheath diameter 2.5 mm, length 35 cm

© K

AR

L S

TOR

Z 9

6082

012

THO

R 1

1 3.

1 11

/201

7/E

W-E

Page 8: Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

8

IMAGE1 S Camera System

* Also available in the following languages: DE, ES, FR, IT, PT, RU

TC 200EN* IMAGE1 S CONNECT™, connect module, for use with up to 3 link modules, resolution 1920 x 1080 pixels, with integrated KARL STORZ-SCB and digital Image Processing Module, power supply 100-120 VAC/ 200-240 VAC, 50/60 Hz including: Mains Cord, length 300 cm DVI-D Connecting Cable, length 300 cm SCB Connecting Cable, length 100 cm USB Flash Drive, 32 GB USB Silicone Keyboard, with touchpad, US

TC 300 IMAGE1 S™ H3-LINK, link module, for use with IMAGE1 FULL HD three- chip camera heads, power supply 100-120 VAC/200-240 VAC, 50/60 Hz, for use with IMAGE1 S CONNECT™ TC 200EN including: Mains Cord, length 300 cm Link Cable, length 20 cm

© K

AR

L S

TOR

Z 9

6082

012

THO

R 1

1 3.

1 11

/201

7/E

W-E

Page 9: Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

9

IMAGE1 S Camera Heads

TH 100 IMAGE1 S™ H3-Z Three-Chip FULL HD Camera Head, progressive scan, soakable, gas- and plasma-sterilizable, with integrated Parfocal Zoom Lens, focal length f = 15-31 mm (2x), 2 freely programmable camera head buttons, for use with IMAGE1 S™ and IMAGE 1 HUB™ HD/IMAGE1 HD

TH 104 IMAGE1 S™ H3-ZA Three-Chip FULL HD Camera Head, autoclavable, progressive scan, soakable, gas - and plasma-sterilizable, with integrated Parfocal Zoom Lens, focal length f = 15-31 mm (2x), 2 freely programmable camera head buttons, for use with IMAGE1 S™ and IMAGE 1 HUB™ HD/IMAGE1 HD

© K

AR

L S

TOR

Z 9

6082

012

THO

R 1

1 3.

1 11

/201

7/E

W-E

Page 10: Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

10

9826 NB 26" FULL HD Monitor, color systems PAL/NTSC, max. screen resolution 1920 x 1080, image format 16:9, video inputs: DVI, 3G-SDI, VGA, S-Video, Composite, video outputs: DVI, 3G-SDI, Composite, power supply 100-240 VAC, 50/60 Hz, 5 V DC output (1 A), wall mount with VESA 100 adaptor including: External 24 VDC Power Supply Mains Cord

9627 NB 27" FULL HD Monitor, color systems PAL/NTSC, max. screen resolution 1920 x 1080, image format 16:9, Interface: RS 232, power supply 85-264 VAC, 50/60 Hz, wall mount with VESA 100 adaptor including: External 24 VDC Power Supply Mains Cord

Optional Accessories:

9826 SF Monitor Stand, basic monitor stand, tiltable, rotation +/-30, disinfectable, color white, VESA 100 adaptor, for use with 26” FULL HD Monitor 9826 NB, 26" 3D Monitor 9826 NB-3D and other monitors

9626 SF Monitor Stand, with integrated cable channel, for use with Monitors 9619 NB, 9626 NB, 9626 NB-2, 9627 NB, 9627 NB-2

KARL STORZ Monitors

© K

AR

L S

TOR

Z 9

6082

012

THO

R 1

1 3.

1 11

/201

7/E

W-E

Page 11: Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

11

Light Source

20 1614 20-1 Cold Light Fountain Power LED 175 SCB, with integrated KARL STORZ-SCB, high-performance LED and one KARL STORZ light outlet, power supply 100-240 VAC, 50/60 Hz

533 TVB Adaptor, with ergonomic swivel, autoclavable, permits telescope changing under sterile conditions (optional)

040112-40 Camera Cover, folded inside out, 13 x 242 cm, sterile, for single use, package of 40, for use with all standard endoscopic video camera systems

It is recommended to check the suitability of the product for the intended procedure prior to use.

© K

AR

L S

TOR

Z 9

6082

012

THO

R 1

1 3.

1 11

/201

7/E

W-E

Page 12: Optical Needle Holder - KARL STORZ · This shows a tracheal rupture and the use of an optical needle holder. References 1. elter S, Darwiche K, Cheufou D, ... USB Silicone Keyboard,

9608

2012

TH

OR

11

3.1

11/2

017/

EW

-E

KARL STORZ SE & Co. KG Dr.-Karl-Storz-Straße 34, 78532 Tuttlingen/Germany Postbox 230, 78503 Tuttlingen/Germany Phone: +49 (0)7461 708-0 Fax: +49 (0)7461 708-105 E-Mail: [email protected]

www.karlstorz.com