Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Job Name: System Reference: Date: Outdoor Unit: 24-TON PUHY-P288TSLMU-A (-BS) (Consists of One PUHY-P120TLMU-A (-BS), One PUHY-P96TLMU-A (-BS), One PUHY-P72TLMU-A (-BS) and One CMY-Y300CBK2 Twinning Kit) Specifications System Module 1 Module 2 Module 3 Unit Type PUHY-P288TSLMU-A (-BS) PUHY-P120TLMU-A (-BS) PUHY-P96TLMU-A (-BS) PUHY-P72TLMU-A (-BS) Nominal Cooling Capacity (208/230V) Btu/h 288,000 120,000 96,000 72,000 Nominal Heating Capacity (208/230V) Btu/h 323,000 135,000 108,000 80,000 Operating Temperature Range *1 Cooling (Outdoor) *2 Refer to Module Data 23~126° F (-5~52° C) DB Heating (Outdoor) -13~60° F (-25~15.5° C) WB External Dimensions (H x W x D) In. (mm) Refer to Module Data 64-31/32 x 68-29/32 x 29-5/32 (1,650 x 1,750 x 740) 64-31/32 x 48-1/16 x 29-5/32 (1,650 x 1,220 x 740) 64-31/32 x 36-1/4 x 29-5/32 (1,650 x 920 x 740) Net Weight Lbs. (kg) 1,605 (727) 671 (304) 499 (226) 435 (197) External Finish Refer to Module Data Pre-coated galvanized steel sheet Electrical Power Requirements Voltage, Phase, Hertz Refer to Module Data** 208 / 230V, 3-Phase, 60Hz Minimum Circuit Ampacity (MCA) A Refer to Module Data** 42 / 39 32 / 29 24 / 22 Maximum Overcurrent Protection (MOP) A Refer to Module Data** 60 / 60 50 / 45 35 / 35 Piping Diameter (Brazed) From Twinning Kit to First Joint or Header (In. / mm) Liquid (High Pressure) 3/4 (19.05) Refer to System Data Gas (Low Pressure) 1-3/8 (34.93) Max. Total Refrigerant Line Length Ft. 3,280 Refer to System Data Max. Refrigerant Line Length (Between ODU & IDU) Ft. 541 Max. Control Wiring Length Ft. 1,640 Indoor Unit Total Capacity 50~130% of outdoor unit capacity Refer to System Data Model / Quantity P06~P96/2~50 Refer to System Data Sound Pressure Level dB(A) 64.0 Refer to System Data Fan Type x Quantity Refer to Module Data Propeller fan x 2 Propeller fan x 1 Propeller fan x 1 Airflow Rate CFM 11,300 6,700 6,200 External Static Pressure In. WG Refer to Module Data Selectable; 0, 0.12 or 0.24”WG; factory set to 0”W.G. Compressor Operating Range 4% to 100% Refer to System Data Compressor Type x Quantity Refer to Module Data Inverter-driven Scroll Hermetic x 1 Inverter-driven Scroll Hermetic x 1 Inverter-driven Scroll Hermetic x 1 Refrigerant Refer to Module Data R410A; 26 lbs. + 1 oz. (11.8 kg) R410A; 22 lbs. + 12 oz. (10.3 kg) R410A; 16 lbs. + 9 oz. (7.5 kg) Protection Devices High Pressure Refer to Module Data High pressure sensor, High pressure switch at 4.15 MPa (601 psi) High pressure sensor, High pressure switch at 4.15 MPa (601 psi) High pressure sensor, High pressure switch at 4.15 MPa (601 psi) Inverter Circuit (Comp. / Fan) Over-current protection Over-current protection Over-current protection AHRI Ratings (Ducted/Non-Ducted) EER 12.0 / 13.5 Refer to System Data IEER 20.4 / 24.0 COP 3.47 / 3.70 UNIT OPTION □ Standard Model…...…...…………......………PUHY-P288TSLMU-A Seacoast (BS) Model…….....……......….PUHY-P288TSLMU-A-BS ACCESSORIES Twinning Kit (required)...............................................…CMY-Y300CBK2 Joint Kit..............................for details see Pipe Accessories Submittal Low Ambient Kit ...............…..for details see Low Ambient Kit Submittal Snow/Hail Guards Kit......…for details see Snow/Hail Guards Kit Submittal Base Pan Heater Kit .............for details see Base Pan Heater Kit Submittal OUTDOOR VRF HEAT PUMP SYSTEM NOTES: *1. When applying product below -4° F, consult your design engineer for cold climate application best practices, including the use of a backup source for heating. *2. For details on extended cooling operation range down to -10° F DB, see Low Ambient Kit Submittal. ** Each individual module requires a separate electrical connection. Refer to electrical data for each individual module.

Outdoor Unit: 24-TON PUHY-P288TSLMU-A (-BS)

  • Upload
    others

  • View
    37

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Outdoor Unit: 24-TON PUHY-P288TSLMU-A (-BS)

Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc.

Job Name:

System Reference: Date:

Outdoor Unit: 24-TON PUHY-P288TSLMU-A (-BS)(Consists of One PUHY-P120TLMU-A (-BS), One PUHY-P96TLMU-A (-BS), One PUHY-P72TLMU-A (-BS) and One CMY-Y300CBK2 Twinning Kit)

Specifications System Module 1 Module 2 Module 3

Unit Type PUHY-P288TSLMU-A (-BS)

PUHY-P120TLMU-A (-BS)

PUHY-P96TLMU-A (-BS)

PUHY-P72TLMU-A (-BS)

Nominal Cooling Capacity(208/230V) Btu/h 288,000 120,000 96,000 72,000

Nominal Heating Capacity(208/230V) Btu/h 323,000 135,000 108,000 80,000

Operating Temperature Range *1 Cooling (Outdoor) *2 Refer to Module Data 23~126° F (-5~52° C) DB Heating (Outdoor) -13~60° F (-25~15.5° C) WB

External Dimensions (H x W x D) In. (mm) Refer to Module Data64-31/32 x 68-29/32 x

29-5/32(1,650 x 1,750 x 740)

64-31/32 x 48-1/16 x 29-5/32

(1,650 x 1,220 x 740)

64-31/32 x 36-1/4 x 29-5/32

(1,650 x 920 x 740)Net Weight Lbs. (kg) 1,605 (727) 671 (304) 499 (226) 435 (197)External Finish Refer to Module Data Pre-coated galvanized steel sheet

Electrical Power Requirements Voltage, Phase, Hertz Refer to Module Data** 208 / 230V, 3-Phase, 60Hz

Minimum Circuit Ampacity (MCA) A Refer to Module Data** 42 / 39 32 / 29 24 / 22

Maximum Overcurrent Protection (MOP) A Refer to Module

Data** 60 / 60 50 / 45 35 / 35

Piping Diameter (Brazed)From Twinning Kit to First Joint or Header (In. / mm)

Liquid (High Pressure) 3/4 (19.05) Refer to System DataGas (Low Pressure) 1-3/8 (34.93)Max. Total Refrigerant Line Length Ft. 3,280

Refer to System DataMax. Refrigerant Line Length (Between ODU & IDU) Ft. 541

Max. Control Wiring Length Ft. 1,640

Indoor UnitTotal Capacity 50~130% of outdoor

unit capacity Refer to System Data

Model / Quantity P06~P96/2~50 Refer to System DataSound Pressure Level dB(A) 64.0 Refer to System DataFanType x Quantity Refer to Module Data Propeller fan x 2 Propeller fan x 1 Propeller fan x 1Airflow Rate CFM 11,300 6,700 6,200External Static Pressure In. WG Refer to Module Data Selectable; 0, 0.12 or 0.24”WG; factory set to 0”W.G.Compressor Operating Range 4% to 100% Refer to System Data

Compressor Type x Quantity Refer to Module Data Inverter-driven Scroll Hermetic x 1

Inverter-driven Scroll Hermetic x 1

Inverter-driven Scroll Hermetic x 1

Refrigerant Refer to Module Data R410A; 26 lbs. + 1 oz. (11.8 kg)

R410A; 22 lbs. + 12 oz.

(10.3 kg)

R410A; 16 lbs. + 9 oz.

(7.5 kg)

Protection DevicesHigh Pressure

Refer to Module Data

High pressure sensor, High

pressure switch at 4.15 MPa (601 psi)

High pressure sensor, High

pressure switch at 4.15 MPa (601 psi)

High pressure sensor, High

pressure switch at 4.15 MPa (601 psi)

Inverter Circuit (Comp. / Fan)

Over-current protection

Over-current protection

Over-current protection

AHRI Ratings(Ducted/Non-Ducted)

EER 12.0 / 13.5Refer to System DataIEER 20.4 / 24.0

COP 3.47 / 3.70

UNIT OPTION □ Standard Model…...…...…………......………PUHY-P288TSLMU-A □ Seacoast (BS) Model…….....……......….PUHY-P288TSLMU-A-BS

ACCESSORIES □ Twinning Kit (required)...............................................…CMY-Y300CBK2 □ Joint Kit..............................for details see Pipe Accessories Submittal □ Low Ambient Kit ...............…..for details see Low Ambient Kit Submittal □ Snow/Hail Guards Kit......…for details see Snow/Hail Guards Kit Submittal □ Base Pan Heater Kit.............for details see Base Pan Heater Kit SubmittalOUTDOOR VRF HEAT PUMP SYSTEM

NOTES:*1. When applying product below -4° F, consult your design engineer for cold climate application best practices, including the use of a backup source for heating.*2. For details on extended cooling operation range down to -10° F DB, see Low Ambient Kit Submittal.

** Each individual module requires a separate electrical connection. Refer to electrical data for each individual module.

Page 2: Outdoor Unit: 24-TON PUHY-P288TSLMU-A (-BS)

Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc.

Outdoor Unit: PUHY-P288TSLMU-A (-BS) – DIMENSIONS

NOTES: SEACOAST PROTECTION • Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.• Standard: Salt Spray Test Method - no unusual rust development to 480 hours.• Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours.

Disc

harg

e air

Outd

oor u

nit 1

Left

view

Fron

t vie

w

Inta

keai

rIn

take

air

Outd

oor u

nit 3

Outd

oor u

nit 2

Inta

keai

r

To in

door

uni

t

To in

door

uni

t

Gas

Tw

inni

ng p

ipe

2 <o

ptio

nal p

arts

>

ba

Liqu

id T

win

ning

pip

e 2

<opt

iona

l par

ts>

ji

Gas

Tw

inni

ng p

ipe

1 <o

ptio

nal p

arts

>

dc

Liqu

id T

win

ning

pip

e 1

<opt

iona

l par

ts>

hg

fe

P72

e or

g o

r iU

nit m

odel

P12

0P

96

Liqu

idG

asf o

r h o

r j

Twin

ning

pip

e~O

utdo

or u

nit

Not

e 1.

Con

nect

the

pipe

s as

sho

wn

in th

e fig

ure

abov

e. R

efer

to th

e ta

ble

abov

e fo

r the

pip

e si

ze.

2.

Twin

ning

pip

es s

houl

d no

t be

tilte

d m

ore

than

15

degr

ees

from

the

horiz

onta

l pla

ne.

Be

sure

to s

ee th

e In

stal

latio

n M

anua

l for

det

ails

of T

win

ning

pip

e in

stal

latio

n.

3.Th

e pi

pe s

ectio

n be

fore

the

Twin

ning

pip

e (s

ectio

ns "a

", "b

", "c

" and

"d" i

n th

e fig

ure)

mus

t hav

e at

leas

t 500

mm

(19-

11/1

6) o

f stra

ight

sec

tion

(*in

clud

ing

the

stra

ight

pip

e th

at is

sup

plie

d w

ith th

e Tw

inni

ng p

ipe)

.

4.O

nly

use

the

Twin

ning

pip

e by

Mits

ubis

hi (o

ptio

nal p

arts

).

dcba

PU

HY-

P72

TLM

U-A

(-B

S)

PU

HY-

P12

0TLM

U-A

(-B

S)

PU

HY-

P96

TLM

U-A

(-B

S)

PU

HY-

P28

8TS

LMU

-A(-

BS

)

Out

door

uni

t 3

Liqu

id

Liqu

idG

as

Gas

Out

door

uni

t 2O

utdo

or u

nit 1

Twin

ning

pip

e 1~

Twin

ning

pip

e 2

Indo

or u

nit~

Twin

ning

pip

e 2

Out

door

Tw

inni

ng K

it(op

tiona

l par

ts)

Com

pone

nt u

nit n

ame

Pac

kage

uni

t nam

eTw

inni

ng p

ipe

conn

ectio

n si

ze

ø22.

2(7/

8)ø9

.52(

3/8)

ø28.

58(1

-1/8

)ø1

2.7(

1/2)

ø22.

2(7/

8)ø9

.52(

3/8)

CM

Y-Y

300C

BK

2ø1

9.05

(3/4

)

ø19.

05(3

/4)

ø34.

93(1

-3/8

)

ø34.

93(1

-3/8

)

920(

36-1

/4)

1220

(48-

1/16

)30

(1-3

/16)

30(1

-3/1

6)17

50(6

8-15

/16)

1650(65)

740(

29-3

/16)

PUHY-P288TSLMU-A(-BS)Unit : mm (in.)

Page 3: Outdoor Unit: 24-TON PUHY-P288TSLMU-A (-BS)

Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc.

Model: PUHY-P120TLMU-A (-BS) – DIMENSIONS

NOTES: SEACOAST PROTECTION • Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.• Standard: Salt Spray Test Method - no unusual rust development to 480 hours.• Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours.

(26-3/4~26-15/16)

(26-13/16)

(3-3

/16)

(3-3

/16)

=(5-15/16)×4 (2-13/16)

(11-15/16)

(4-13/16)

(5-3/4)

(3-5/16)

(1-3/16) (1-3/16)

(3-3/4)

(6)(7-3/4)

(8-9/16)

(3-9/16)(3-1/16)

(23-5/8)

(13/

16)

(13/

16)

(23-

1/8)

(13/

16)

(13/

16)

(2-1

/4)

(2-1

/4)

2×2-

80(3

-3/1

6)×3

5(1-

7/16

) Ova

l hol

e<S

ling

hole

>

Dis

char

ge a

ir

Inta

keai

rIn

take

air

Ser

vice

pane

l

Inta

keai

r

2×3-

14(9

/16)

×20(

13/1

6) O

val h

ole

(Mounting pitch)

(Mou

ntin

g pi

tch)

(Mou

ntin

g pi

tch)

Con

trol b

ox

Ref

riger

ant s

ervi

ce v

alve

<liq

uid>

Ref

riger

ant s

ervi

ce v

alve

<ga

s>

Ser

vice

pan

el

2×7-

ø4.6

(3/1

6) H

ole

(Mak

e ho

le a

t the

pla

stic

fan

guar

d fo

r sno

w h

ood

atta

chm

ent)

<Sno

w h

ood

atta

chm

ent h

ole>

Ref

riger

ant s

ervi

ce

valv

e <g

as>

Ref

riger

ant s

ervi

ceva

lve

<liq

uid>

(6-13/16)

(8-13/16)

Fan

box

Fron

t vie

w

Top

view

Left

side

vie

w

Bot

tom

vie

w

(5-15/16)

*1 E

xpan

d th

e on

-site

pip

ing

and

conn

ect t

o th

e re

frige

rant

ser

vice

val

ve p

ipin

g.

*2 U

se th

e pi

pe jo

int(f

ield

sup

ply)

and

con

nect

to th

e re

frige

rant

ser

vice

v

alve

pip

ing.

*3

Indi

cate

s di

men

sion

s an

d co

nnec

tion

spec

ifica

tions

in th

e ca

se th

e un

it is

use

d in

com

bina

tion

with

oth

er o

utdo

or u

nits

. *4

Fur

thes

t pip

ing

leng

th (O

U fr

om IU

) ≥40

m(1

31ft)

(1-3

/8)

ø34

Kno

ckou

t hol

eFo

r tra

nsm

ission

cable

s

(2-1

/16)

ø52

Kno

ckou

t hol

e

For p

ipes

(5-1

5/16

)(3-

3/4)

150

× 94

Kno

ckou

t hol

e(5

-9/1

6)(3

-1/1

6)14

0 ×

77 K

nock

out h

ole

NO

.U

sage

For w

ires

Botto

m th

roug

h ho

le

Fron

t thr

ough

hol

e

Fron

t thr

ough

hol

e

Fron

t thr

ough

hol

e

Botto

m th

roug

h ho

le

Botto

m th

roug

h ho

le

Fron

t thr

ough

hol

e

(1-3

/8)

ø62.

7 or

ø34

.5 K

nock

out h

ole

(2-1

/2)

(7/8

)ø4

3.7

or ø

22.2

Kno

ckou

t hol

e(1

-3/4

)

Spe

cific

atio

ns

ø65

Kno

ckou

t hol

e(2

-9/1

6)

*1(1

/2)

ø12.

7 Br

azed

(1/2

)ø1

2.7

*1(1

-1/8

)ø2

8.58

Bra

zed

(1-1

/8)

ø28.

58

Ref

riger

ant p

ipe

Ser

vice

val

veD

iam

eter

Mod

el

Con

nect

ing

pipe

spe

cific

atio

ns

*1 *3

*4

*2ø9

.52

Braz

ed(3

/8)

(1/2

)(ø

12.7

Bra

zed)

PUH

Y-P1

44TL

MU

PUH

Y-P1

20TL

MU

Gas

Gas

Liqu

idLi

quid

*2(5

/8)

ø15.

88 B

raze

dPU

HY-

P168

TLM

U

58(2

-5/1

6)75

(3)

54

1(21

-5/1

6)

217

172

196151121

303

2

1

4

73

56

1347(53-1/16)

1650(65)

1750

(68-

15/1

6)19

.583

1(32

-3/4

)83

1(32

-3/4

)19

.5600=150×4 70

(740)(29-3/16)

29.529.5

562(

22-3

/16)

740(29-3/16)

77 89

8079

5(31

-5/1

6)79

5(31

-5/1

6)80

681(678~684)

140(

5-9/

16)

49(1

-15/

16)

54(2-3/16) 57

20 586

57

20223

145

590(

23-1

/4)

83(3

-5/1

6)15

0(5-

15/1

6)56

1(22

-1/8

)

516(

20-3

/8)

84 94

150

1 2 43 5 6 7

Not

e1.P

leas

e re

fer t

o th

e en

gine

erin

g m

anua

l for

info

rmat

ion

rega

rdin

g ne

cess

ary

spac

ing

arou

nd th

e un

it an

d

fo

unda

tion

wor

k. O

utdo

or u

nit m

ust b

e m

ount

ed a

t lea

st

2

.At b

razi

ng o

f pip

es,w

rap

the

refri

gera

nt s

ervi

ce v

alve

w

ith w

et c

loth

and

kee

p th

e te

mpe

ratu

re o

f

re

frige

rant

ser

vice

val

ve u

nder

120

°C(2

48 °

F).

12" o

ff th

e gr

ound

or 1

2" a

bove

the

high

est a

vera

ge s

now

dept

h, w

hich

ever

is g

reat

er.

Unit : mm (in.)PUHY-P120, 144, 168TLMU-A

Page 4: Outdoor Unit: 24-TON PUHY-P288TSLMU-A (-BS)

Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc.

Model: PUHY-P96TLMU-A (-BS) – DIMENSIONS

NOTES: SEACOAST PROTECTION • Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.• Standard: Salt Spray Test Method - no unusual rust development to 480 hours.• Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours.

(8-9/16)

Bot

tom

vie

w

Left

side

vie

wFr

ont v

iew

Top

view

(1-3/16) (1-3/16)(Mounting pitch)

(26-3/4~26-15/16)

(26-13/16)

(Mou

ntin

g pi

tch)

(3-3

/16)

(3-3

/16)

Ref

riger

ant s

ervi

ce

valv

e <g

as>

Ref

riger

ant s

ervi

ceva

lve

<liq

uid>

(4-13/16)(5-3/4)(7-3/4)

(5-3/4)

(3-5/16) (3-3/4)

(5-1

5/16

)(1

0-3/

4)(1

1-7/

8)(8

-15/

16)

(8-3/4)

(6-13/16)(2

-1/4

)(2

-1/4

)

(13/

16)

(13/

16)

(3-9/16)(3-1/16)

1

(9-1

5/16

)(1

0-3/

4)

(11-15/16)

(13/

16)

(13/

16)

(2-13/16)=(5-15/16)×4

(5-15/16)

(23-5/8)

<Sno

w h

ood

atta

chm

ent h

ole>

4×5-

ø4.6

(3/1

6) H

ole

(Mak

e ho

le a

t the

pla

stic

fan

guar

d fo

r sno

w h

ood

atta

chm

ent)

Inta

keai

r

Dis

char

ge a

ir

Ref

riger

ant s

ervi

ce v

alve

<ga

s>

Ref

riger

ant s

ervi

ce v

alve

<liq

uid>

Con

trol b

ox

Inta

keai

r

Ser

vice

pane

l

Inta

keai

r

<Slin

g ho

le>

2

5347

2×2-

14(9

/16)

×20(

13/1

6) O

val h

ole

2×2-

80(3

-3/1

6)×3

5(1-

7/16

) Ova

l hol

e

6

*1 E

xpan

d th

e on

-site

pip

ing

and

conn

ect t

o th

e re

frige

rant

ser

vice

val

ve p

ipin

g.*2

Use

the

pipe

join

t(fie

ld s

uppl

y) a

nd c

onne

ct to

the

refri

gera

nt s

ervi

ce

val

ve p

ipin

g.*3

Fur

thes

t pip

ing

leng

th (O

U fr

om IU

)≥90

m(2

95ft)

NO

.

Fron

t thr

ough

hol

e

Bot

tom

thro

ugh

hole

Bot

tom

thro

ugh

hole

Fron

t thr

ough

hol

e

Fron

t thr

ough

hol

e

For w

iresU

sage

Fron

t thr

ough

hol

e

Bot

tom

thro

ugh

hole

For p

ipes

For t

rans

miss

ion

cabl

es

Spe

cific

atio

ns

Gas

Liqu

idR

efrig

eran

t pip

eLi

quid

Dia

met

erM

odel

Ser

vice

val

ve

Con

nect

ing

pipe

spe

cific

atio

ns

Gas

PUHY

-P96

TLM

U

(3-1

/16)

140

× 77

Kno

ckou

t hol

e(5

-9/1

6)

(5-1

5/16

)15

0 ×

94 K

nock

out h

ole

(3-3

/4)

ø62.

7 or

ø34

.5 K

nock

out h

ole

ø43.

7 or

ø22

.2 K

nock

out h

ole

ø65

Kno

ckou

t hol

e(2

-9/1

6)ø5

2 K

nock

out h

ole

(2-1

/16)

(1-3

/8)

ø34

Kno

ckou

t hol

e

(2-1

/2)

(1-3

/8)

(1-3

/4)

(7/8

)

(7/8

)ø2

2.2

Bra

zed

*2(1

/2)

(ø12

.7 B

raze

d)(3

/8)

ø9.5

2 Br

azed

*1 *2 *

3

ø28.

58(1

-1/8

)ø9

.52

(3/8

)

217

145

222

(740)(29-3/16)

150

83(3

-5/1

6)27

230

1

57

29.5

54(2-3/16)

58(2

-5/1

6)

8010

60(4

1-3/

4)

586(

23-1

/8)

57

9484

121

227

600=150×4

2075

(3)

1220

(48-

1/16

)

172

150

1650(65)

196

272

1347(53-1/16)

89

303

29.5

20

740(29-3/16)

70

1181

(46-

1/2)

140(

5-9/

16)

80

77

146

251

681(678~684)

19.5

19.5

1 2 43 5 6 7

Not

e1.P

leas

e re

fer t

o th

e en

gine

erin

g m

anua

l for

info

rmat

ion

rega

rdin

g ne

cess

ary

spac

ing

arou

nd th

e un

it an

d

fo

unda

tion

wor

k. O

utdo

or u

nit m

ust b

e m

ount

ed a

t lea

st

2

.At b

razi

ng o

f pip

es,w

rap

the

refri

gera

nt s

ervi

ce v

alve

w

ith w

et c

loth

and

kee

p th

e te

mpe

ratu

re o

f

re

frige

rant

ser

vice

val

ve u

nder

120

°C(2

48 °

F).

12" o

ff th

e gr

ound

or 1

2" a

bove

the

high

est a

vera

ge s

now

dept

h, w

hich

ever

is g

reat

er.

Unit : mm (in.)PUHY-P96TLMU-A(-BS)

Page 5: Outdoor Unit: 24-TON PUHY-P288TSLMU-A (-BS)

Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc.

Model: PUHY-P72TLMU-A (-BS) – DIMENSIONS

NOTES: SEACOAST PROTECTION • Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.• Standard: Salt Spray Test Method - no unusual rust development to 480 hours.• Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours.

217

58(2

-5/1

6)75

(3)

201

145(5-3/4)

740(29-3/16)

140(

5-9/

16)

8977

303 1347(53-1/16)

1650(65)

600=150×4150

70

920(

36-1

/4)

881(

34-1

1/16

)

222

681(678~684)

8076

0(29

-15/

16)

80

(740)(29-3/16)

29.5 29.5

54(2-3/16)

57

20

586(

23-1

/8)

20

57

9484(3-5/16)

222172

222

150(

5-15

/16)

251

8317

7

121146

196

19.5

19.5

Left

side

vie

w

Top

view

Fron

t vie

w

Bot

tom

vie

w

Con

trol b

ox

<Sno

w h

ood

atta

chm

ent h

ole>

2×5-

ø4.6

(3/1

6) H

ole

(Mak

e ho

le a

t the

pla

stic

fan

guar

d fo

r sno

w h

ood

atta

chm

ent)

(2-13/16)

(5-15/16)

=(5-15/16)×4(23-5/8)

(11-15/16)

(3-1/16) (3-9/16)

(8-9/16)

Ser

vice

pane

l

Inta

keai

rIn

take

air

Inta

keai

r

Dis

char

ge a

ir

(6-13/16)

(8-3/4)(1

3/16

)(1

3/16

)

(2-1

/4)

(2-1

/4)

Ref

riger

ant s

ervi

ce v

alve

<ga

s>

Ref

riger

ant s

ervi

ce v

alve

<liq

uid>

(4-13/16)

(7-3/4)(5-3/4)

(3-5

/16)

Ref

riger

ant s

ervi

ceva

lve

<liq

uid>

Ref

riger

ant s

ervi

ce

valv

e <g

as>

(Mou

ntin

g pi

tch)

(3-3

/16)

(3-3

/16)

(26-13/16)

(Mounting pitch)(26-3/4~26-15/16)(1-3/16) (1-3/16)

(3-3/4)

(13/

16)

(13/

16)

(7-1

5/16

)(8

-3/4

)

(8-3

/4)

(9-1

5/16

)(7

)

74 3

1

2×2-

14(9

/16)

×20(

13/1

6) O

val h

ole

265

2×2-

80(3

-3/1

6)×3

5(1-

7/16

) Ova

l hol

e<S

ling

hole

>

*1 E

xpan

d th

e on

-site

pip

ing

and

conn

ect t

o th

e re

frige

rant

ser

vice

val

ve p

ipin

g.*2

Use

the

pipe

join

t(fie

ld s

uppl

y) a

nd c

onne

ct to

the

refri

gera

nt s

ervi

ce

v

alve

pip

ing.

NO

.

Fron

t thr

ough

hol

e

Botto

m th

roug

h ho

le

Botto

m th

roug

h ho

le

Fron

t thr

ough

hol

e

Fron

t thr

ough

hol

e

For w

ires

Usa

ge Fron

t thr

ough

hol

e

Botto

m th

roug

h ho

leFo

r pip

es

For t

rans

miss

ion ca

bles

Spe

cific

atio

ns

PU

HY-

P72

TLM

U

Gas

Con

nect

ing

pipe

spe

cific

atio

nsS

ervi

ce v

alve

Mod

elD

iam

eter

Liqu

idR

efrig

eran

t pip

eLi

quid

Gas

(3-1

/16)

140

× 77

Kno

ckou

t hol

e(5

-9/1

6)

(5-1

5/16

)15

0 ×

94 K

nock

out h

ole

(3-3

/4)

ø62.

7 or

ø34

.5 K

nock

out h

ole

ø43.

7 or

ø22

.2 K

nock

out h

ole

ø65

Knoc

kout

hol

e(2

-9/1

6)ø5

2 Kn

ocko

ut h

ole

(2-1

/16)

(1-3

/8)

ø34

Knoc

kout

hol

e

(2-1

/2)

(1-3

/8)

(1-3

/4)

(7/8

)

(7/8

)*2

ø22.

2 B

raze

d

(1-1

/8)

ø28.

58

(3/8

)ø9

.52

(3/8

) *1

ø9.5

2 B

raze

d

1 2 43 5 6 7Not

e1.P

leas

e re

fer t

o th

e en

gine

erin

g m

anua

l for

info

rmat

ion

rega

rdin

g ne

cess

ary

spac

ing

arou

nd th

e un

it an

d

fo

unda

tion

wor

k. O

utdo

or u

nit m

ust b

e m

ount

ed a

t lea

st

2

.At b

razi

ng o

f pip

es,w

rap

the

refri

gera

nt s

ervi

ce v

alve

w

ith w

et c

loth

and

kee

p th

e te

mpe

ratu

re o

f

re

frige

rant

ser

vice

val

ve u

nder

120

°C(2

48 °

F).

12" o

ff th

e gr

ound

or 1

2" a

bove

the

high

est a

vera

ge s

now

dept

h, w

hich

ever

is g

reat

er.

Unit : mm (in.)PUHY-P72TLMU-A(-BS)

Page 6: Outdoor Unit: 24-TON PUHY-P288TSLMU-A (-BS)

Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc.

1340 Satellite Boulevard. Suwanee, GA 30024Toll Free: 800-433-4822 www.mehvac.com

Twinning Kit: CMY-Y300CBK2

The angle of the branch pipe for hign pressure is within against the horizontal plane. 2. Use the attached pipe to braze the port-opening of the distributer.3. Pipe diameter is indicated by inside diameter.4. Only use the Twinning pipe by Mitsubishi (optional parts) .

Note 1. Reference the attitude angle of the branch pipe below the fig.

Distributer

15

15

FORM# PUHY-P288TSLMU-A (-BS) - 201605

For Gas pipe: For Liquid pipe:

ID: Inner Diameter OD: Outer Diameter

Ref.: CMY_Y300VBK2_EXD_EUDB_SIin.CMY-Y300CBK2

<Reducer(Accessory)>

Note 2

1/2"

5/8"1/2"

1/2"

3/4"1/2"

Pipe cover

Local brazing

3-7/8"

Local brazing

Pipe cover 5/8"3/4"

3/4"

5/8"3/4"

5/8"

9-11/16"

3-3/8"

7-9/16"

4-9/16

"

7-5/16"

9-5/8"

(Dot-dashed part)

(Dot-dashed part)

Note 2

Distributer

Distributer

3/8"

1-1/8" 7/8"

1/2"

1-15/16"

2-1/2"

1/2"5/8"

5/8" 3/8"

1-15/16"

1-15/16"

1/2" 5/8"

(2 pcs.)1-15/16"

1-5/8"1-1/2"

(3 pcs.)

1-1/8" 3/4"

1-3/8"1-1/2"

2-1/2"(2 pcs.)

2-3/4"

2-3/4"

1-3/8"

Pipe cover

Local brazing1-1/4"

1-1/8"

1-3/8"

1-1/8"1-1/8"

6-7/16

"

1-1/8"

1-1/8"1"

1-1/8"

1"

Local brazing

Pipe cover

19-15/16"

22-15/16"

13-3/8"

23-1/16"

13-5/16"

1-1/2"

Note 2

(Dot-dashed part)

(Dot-dashed part)

Note 2

Distributer

Distributer

19-11/16"

6-7/16

"

3-3/8"