4
Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Passive House Efficiency Class phA advanced component phB basic component phC certifiable component not suitable for Passive Houses Certified Passive House component for cool, temperate climate, valid until 31.12.2014 Category: Window Frame Manufacturer: Hilzinger FBS GmbH 53909 Zülpich, GERMANY Product name: VADB-Plus 550 The following comfort criteria were used in awarding this certificate: Given a U g value of 0.70 W/(m²K) and a window size of 1.23 m by 1.48 m, U W = 0.76 W/(m²K) 0.80 W/(m²K) Taking into account the installation based thermal bridges, and provided that the installation is, with regard to the thermal bridges, equal or better than shown in the data sheet, the window meets the following criterion. U W,installed 0.85 W/(m²K) Thermal data of the window frame U f -value Width Ψ g f Rsi=0.25 [W/(m²K)] [mm] [W/(mK)] [-] Spacer Bottom 0.68 100 0.024 Side/top 0.64 75 0.026 *Spacers of lower thermal quality, especially those made of alu- minium, lead to significantly higher thermal losses and lower temperature factors. Further information see data sheet www.passivehouse.com 0037wi03 TPS* 0.73

Passive House Institute - Catalogue produitspmp-catalogues.be/files/chassis/103/zd-hilzinger-fbs...Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Passive House

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Passive House Institute - Catalogue produitspmp-catalogues.be/files/chassis/103/zd-hilzinger-fbs...Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Passive House

Passive House InstituteDr. Wolfgang Feist 64283 DarmstadtGERMANY

Passive HouseEfficiency Class

phAadvanced

component

phBbasic

component

phCcertifiable

component

not suitable for Passive Houses

Certified Passive House componentfor cool, temperate climate, valid until 31.12.2014

Category: Window FrameManufacturer: Hilzinger FBS GmbH

53909 Zülpich, GERMANYProduct name: VADB-Plus 550

The following comfort criteria were used in awarding this certificate:

Given a Ug value of 0.70 W/(m²K) and a window size of

1.23 m by 1.48 m,

UW = 0.76 W/(m²K) ≤ 0.80 W/(m²K)

Taking into account the installation based thermal bridges, andprovided that the installation is, with regard to the thermal bridges,equal or better than shown in the data sheet, the window meetsthe following criterion.

UW,installed ≤ 0.85 W/(m²K)

Thermal data of the window frame

Uf-value Width Ψg fRsi=0.25

[W/(m²K)] [mm] [W/(mK)] [-]SpacerBottom 0.68 100 0.024Side/top 0.64 75 0.026

*Spacers of lower thermal quality, especially those made of alu- minium, lead to significantly higher thermal losses and lower temperature factors.

Further information see data sheet

www.passivehouse.com 0037wi03

TPS*

0.73

Page 2: Passive House Institute - Catalogue produitspmp-catalogues.be/files/chassis/103/zd-hilzinger-fbs...Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Passive House

Data Sheet Hilzinger FBS GmbH, VADB-Plus 550

Manufacturer Hilzinger FBS GmbHBergheimer Str. 21, 53909 Zülpich, GERMANYTel.: +49 (0)2252 2064Email: [email protected], www.hilzinger.de

Bottom section Isothermal

Description

Thermal data for the window frame

Uf-value Width Ψg fRsi=0.25

[W/(m²K)] [mm] [W/(mK)] [-]SpacerBottom 0.68 100 0.024Side/top 0.64 75 0.026Mullion 110 0.67 110 0.026 0.73Mullion 125 0.64 125 0.025 0.73

Mullion

* Spacers of lower thermal quality leading to higher thermal losses and lower temperatures.

www.passivehouse.com Passive House Institute Page 1/3

Plastic frame

TPS*

0.73

Page 3: Passive House Institute - Catalogue produitspmp-catalogues.be/files/chassis/103/zd-hilzinger-fbs...Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Passive House

Data Sheet Hilzinger FBS GmbH, VADB-Plus 550

Installation

Installation based thermal bridge Ψinstal.

in Passive House suitable walls

Bottom [W/(mK)] 0.016 0.028 0.011Side/top [W/(mK)] 0.007 0.020 0.007UW,instal. [W/(m²K)] 0.79 0.82 0.78

Explanatory notes

U Glazing Ug [W/(m²K)] 0.66 0.60 0.54

U Window UW [W/(m²K)] 0.73 0.68 0.63

www.passivehouse.com Passive House Institute Page 2/3

EIF

S

Tim

ber

cons

truc

tion

wal

l

Insu

late

d fo

rmw

ork

bloc

ks

The window U-values were calculated based on a 1.23 m by 1.48 m window Ug = 0.70 W/(m²K).If better glazing is used, the window U-value decrease as follow:

Depending on the thermal losses through opaque elements, windows are categorised according to efficency classes. These thermal losses include the losses through the frame, multiplied by its width, the thermal bridge at the edge bondedge bond as well as the length of the edge bond.Please ask the manufacturer for a detailed report containing all calculations and results.For further information, please visit www.passivehouse.com or www.passipedia.org.

Position

Page 4: Passive House Institute - Catalogue produitspmp-catalogues.be/files/chassis/103/zd-hilzinger-fbs...Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Passive House

Datenblatt FBS Over GmbH, VADB-Plus 550 S

Manufacturer Hilzinger FBS GmbHBergheimer Str. 21, 53909 Zülpich, GERMANYTel.: +49 (0)2252 2064Email: [email protected], www.hilzinger.de

Bottom section Isothermal

Description

Thermal data for the window frame

Uf-value width Ψg fRsi=0.25

[W/(m²K)] [mm] [W/(mK)] [-]AbstandhalterUnten 0.81 100 0.025Seitlich/oben 0.84 75 0.025Stulp 110 0.83 110 0.024 0.72Stulp 125 0.85 125 0.025 0.72

* Spacers of lower thermal quality leading to higher thermal losses and lower temperatures. Mullion

www.passivehouse.com Passive House Institute Page 3/3

0.73

Plastic frame reinforced with steel

TPS*