16
Pebbletex Adhered Mat Design Typical Details

Pebbletex Adhered Mat Design - BASF

  • Upload
    others

  • View
    17

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Pebbletex Adhered Mat Design - BASF

Pebbletex Adhered Mat DesignTypical Details

Page 2: Pebbletex Adhered Mat Design - BASF

(THIS PAGE INTENTIONALLY LEFT BLANK)

Page 3: Pebbletex Adhered Mat Design - BASF

1. Pebbletex Adhered Mat Design Application (Plan VIew)

2. Pebbletex Adhered Mat Design (Isometric View)

3. Aesthetic Groove

4. Insulation Boards / Reinforcing Mesh Application at Openings

5. Window Head (Flush)

6. Window Head (Recessed)

7. Window Jamb Detail (Flush)

8. Window Jamb Detail (Recessed)

9. Window Sill Detail (Flush)

10. Window Sill Detail (Recessed)

11. Roof Edge Flashing Detail

12. Metal Coping Detail

13. Parapet Cap Detail

14. Expansion Joint Detail at Floorline

15. Expansion Joint at Change in Substrate

16. Section at Fascia/Soffit

17. Expansion Joint Detail

18. Pipe Penetration

19. Corner Mesh Application with STRONG 15 or HI-IMPACT 20 (Plan View)

20. Corner Mesh Application with Standard Mesh, INTERMEDIATE 6 or 12 (Plan View)

21. Light Fixture

22. Termination at Foundation

23. Termination at Foundation (Flush)

24. Kick-out Flashing Detail

Pebbletex Adhered Mat Design

TABLE OF CONTENTS

Page 4: Pebbletex Adhered Mat Design - BASF

0616

Pebbletex® Adhered Mat Design

AM-01 TYPICAL PEBBLETEX ADHERED MAT DESIGN APPLICATION (PLAN VIEW)

AM-02 TYPICAL PEBBLETEX ADHERED MAT DESIGN (ISOMETRIC VIEW)

ACCEPTABLE SHEATHING

PERMALATH 1000 OR METAL LATH

FINESTONE INSULATION BOARD

FRAMING

FINESTONE REINFORCING MESH

FINESTONE BASE COAT

FINESTONE FINISH COAT

MECHANICAL FASTENER

ACCEPTABLE SHEATHING

FINESTONE INSULATION BOARD

FRAMING

FINESTONE BASE COAT

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

PERMALATH 1000 OR METAL LATH

MECHANICAL FASTENER

FINESTONE BASE COAT

SELF-ADHERING MESH TAPE (4”), 4” SHEATHING FABRIC OR BASF WS FLASH

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

FINESTOP®, FINESTOP RA OR SECOND-ARY MOISTURE PROTECTION BARRIER

Page 5: Pebbletex Adhered Mat Design - BASF

0616

AM-03 TYPICAL AESTHETIC GROOVE (PLAN VIEW)

AM-04 TYPICAL INSULATION BOARDS/REINFORCING MESH APPLICATION AT OPENINGS

WRAP FINESTONE BASE COAT ANDSTANDARD MESH REINFORCING MESH AT INSULATION BOARD EDGES

FINESTONE INSULATION BOARD

STAGGER INSULATION BOARDJOINTS AT CORNER OF OPENINGS

STANDARD MESH REINFORCING MESH EMBEDDED IN FINESTONE BASE COAT

NOTE: • TYPICAL AT WINDOWS, DOORS, ETC.• MAINTAIN A MIN. 13 mm (1/2”) PERIMETER SEALANT JOINT• FLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN/CODE REQUIREMENTS

229 mm (9”)

305 mm (12”)

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

ACCEPTABLE SHEATHING

FINESTONE INSULATION BOARD

FRAMING

AESTHETIC GROOVE

MIN. 19 mm (3/4”)

PERMALATH 1000 OR METAL LATH

FINESTONE BASE COAT

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

MECHANICAL FASTENER

Page 6: Pebbletex Adhered Mat Design - BASF

0616

Pebbletex® Adhered Mat Design

AM-05 TYPICAL WINDOW HEAD (FLUSH)

AM-06 TYPICAL WINDOW HEAD (RECESSED)

ACCEPTABLE SHEATHING

BACKER ROD AND SEALANT

BASF COLOR COAT

FRAMING

WINDOW

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

ACCEPTABLE SHEATHING

SELF-ADHERING MESH TAPE (4”), 4” SHEATHING FABRIC OR BASF WS FLASH

FINESTONE INSULATION BOARD

FRAMING

WINDOW

FLASHING W/ SEALANT

FINESTONE BASE COAT

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

MECHANICAL FASTENER

PERMALATH 1000 OR METAL LATH

NOTE: IF SECONDARY MOISTURE PROTECTION BARRIER IS USED IN LIEU OF FINESTOP OR FINESTOP RA, ENSURE BARRIER IS PROPERLY LAPPED OVER THE FLASHING FLANGE.

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

FINESTONE INSULATION BOARD

FINESTONE BASE COAT

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

MECHANICAL FASTENER

PERMALATH 1000 OR METAL LATH

WRAP BASE COAT AND FINESTONE REINFORCING MESH

Page 7: Pebbletex Adhered Mat Design - BASF

0616

AM-07 TYPICAL WINDOW JAMB DETAIL (FLUSH)

AM-08 TYPICAL WINDOW JAMB DETAIL (RECESSED)

ACCEPTABLE SHEATHING

FINESTONE INSULATION BOARD

FINESTONE BASE COAT

BACKER ROD AND SEALANT

BASF COLOR COAT

PERMALATH 1000 OR METAL LATH

SEE ALTERNATE OPTION DETAIL

FINESTOP® FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

FRAMING

MECHANICAL FASTENER

SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA

WINDOW

ACCEPTABLE SHEATHING

FINESTONE INSULATION BOARD

FINESTONE BASE COAT

PERMALATH 1000 OR METAL LATH

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

FRAMING

MECHANICAL FASTENER

SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA

WINDOW

WRAP BASE COAT AND FINESTONE REINFORCING MESH

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

BACKER ROD AND SEALANT

BASF COLOR COAT

BASF WS FLASH

FINESTOP OR FINESTOP RA

ALTERNATE OPENING PROTECTION OPTION FOR WINDOW JAMBS (WS FLASH MAY BE APPLIED UNDER OR OVER THE FINESTOP OR FINESTOP RA).

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

WRAP BASE COAT AND FINESTONE REINFORCING MESHALTERNATE OPENING

PROTECTION OPTION FOR WINDOW JAMBS (WS FLASH MAY BE APPLIED UNDER OR OVER THE FINESTOP OR FINESTOP RA).

WS FLASH

FINESTOP OR FINESTOP RA

Page 8: Pebbletex Adhered Mat Design - BASF

0616

Pebbletex® Adhered Mat Design

AM-09 TYPICAL SILL DETAIL (FLUSH)

AM-10 TYPICAL SILL DETAIL (RECESSED)

SEE ALTERNATE OPTION DETAIL

ACCEPTABLE SHEATHING

FINESTONE INSULATION BOARDFINESTONE BASE COAT

BACKER ROD AND SEALANTFINESTONE ASAP

PERMALATH 1000 OR METAL LATH

BASF WS FLASH

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

FINESTOP OR FINESTOP RA

FRAMING

MECHANICAL FASTENER

SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA

WINDOW

WRAP BASE COAT AND FINESTONE REINFORCING MESH

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

ALTERNATE OPENING PROTECTION OPTION FOR WINDOW SILL (WS FLASH MAY BE APPLIED UNDER OR OVER THE FINESTOP OR FINESTOP RA).

SEE ALTERNATE OPTION DETAIL

ACCEPTABLE SHEATHING

FINESTONE INSULATION BOARDFINESTONE BASE COAT

PAN FLASHING

PERMALATH 1000 OR METAL LATH

BASFF WS FLASH

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

FINESTOP OR FINESTOP RA

FRAMING

MECHANICAL FASTENER

SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA

WINDOW

WRAP BASE COAT AND FINESTONE REINFORCING MESH

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

ALTERNATE OPENING PROTECTION OPTION FOR WINDOW SILL (WS FLASH MAY BE APPLIED UNDER OR OVER THE FINESTOP OR FINESTOP RA).

SEALANT

NOTE: • EXTEND FLASHING MIN. 50 mm (2”) OVER EIFS• FLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN/CODE REQUIREMENTS

Page 9: Pebbletex Adhered Mat Design - BASF

0616

AM-12 TYPICAL METAL COPING DETAIL

METAL COPING

AM-11 TYPICAL ROOF EDGE FLASHING DETAIL

ACCEPTABLE SHEATHING

FRAMING

FINESTONE INSULATION BOARD

FINESTONE BASE COAT

SEALANT

ROOF SYSTEM

ROOF EDGE FLASHING

WRAP BASE COAT AND FINESTONE REINFORCING MESH

PERMALATH 1000 OR METAL LATH

MIN. 50 mm (2”)

MIN. 50 mm (2”)

ROOF SYSTEM

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

MECHANICAL FASTENER

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

ACCEPTABLE SHEATHING

FINESTONE INSULATION BOARD

FINESTONE BASE COAT

SEALANT

PERMALATH 1000 OR METAL LATH

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

MECHANICAL FASTENER

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

WRAP BASE COAT AND FINESTONE REINFORCING MESH

FRAMING

Page 10: Pebbletex Adhered Mat Design - BASF

0616

Pebbletex® Adhered Mat Design

AM-13 TYPICAL PARAPET CAP DETAIL

AM-14 TYPICAL EXPANSION JOINT DETAIL AT FLOORLINE

ACCEPTABLE SHEATHING

FRAMING

FINESTONE INSULATION BOARD

FLOOR SLAB

MIN. 19 mm (3/4”)

MIN. 25 mm (1”)

SEALANT

FINESTONE BASE COAT

BACKER ROD AND SEALANT

ROOF SYSTEM

12

6

MIN. 203 mm

(8” )

PERMALATH 1000 OR METAL LATH

SLIP TRACK

BASF WS FLASH

FLASHING

ACCEPTABLE SHEATHING

FINESTONE INSULATION BOARD

FINESTONE BASE COAT

PERMALATH 1000 OR METAL LATH

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

MECHANICAL FASTENER

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

FRAMING

SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA

WRAP BASE COAT AND FINESTONE REINFORCING MESH

EPS CAP

NOTE: FLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN/CODE REQUIREMENTS

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

WRAP BASE COAT AND FINESTONE REINFORCING MESH

BASF COLOR COAT

WIDTH PER DESIGN

Page 11: Pebbletex Adhered Mat Design - BASF

0616

AM-15 TYPICAL EXPANSION JOINT AT CHANGE IN SUBSTRATE

AM-16 TYPICAL SECTION AT FASCIA/SOFFIT

ACCEPTABLE SHEATHING

FRAMING

FINESTONE INSULATION BOARD

ACCEPTABLE SHEATHING

FINESTONE INSULATION BOARD

BACKER ROD AND SEALANT

BASF COLOR COAT

NOTE: JOINT WIDTH PER DESIGN

PEBBLETEX CLASSIC PB SYSTEM

PERMALATH 1000 OR METAL LATH

FINESTONE BASE COAT

PERMALATH 1000 OR METAL LATH

FINESTONE BASE COAT

BASF WS FLASH

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

WRAP BASE COAT AND FINESTONE REINFORCING MESH

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

ACCEPTABLE SUBSTRATE

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

WRAP BASE COAT AND FINESTONE REINFORCING MESH

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

NOTE: EXTEND FINESTOP OR FINESTOP RA A MIN. OF 102 MM (4”) ONTO SOFFIT. USE APPROPRIATE REINFORCEMENT AT CORNER.

Page 12: Pebbletex Adhered Mat Design - BASF

0616

Pebbletex® Adhered Mat Design

AM-17 TYPICAL EXPANSION JOINT DETAIL

AM-18 TYPICAL PIPE PENETRATION

ACCEPTABLE SHEATHING

FRAMING

FINESTONE INSULATION BOARD

SEALANT AT PERIMETER OF PENETRATION

BACKER ROD AND SEALANT

BASF COLOR COAT

MIN. 13 mm (1/2”)

ACCEPTABLE SHEATHING

FRAMING

FINESTONE INSULATION BOARD

BASF WS FLASH

FINESTONE BASE COAT

BACKER ROD AND SEALANTWIDTH PER DESIGN

PERMALATH 1000 OR METAL LATH

BASF COLOR COAT

FINESTONE BASE COAT

PERMALATH 1000 OR METAL LATH

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING • MESH• FINESTONE FINISH COAT

WRAP BASE COAT AND FINESTONE REINFORCING MESH

FINESTOP®, FINESTOP RA OR SEC-ONDARY MOISTURE PROTECTION BARRIER

WRAP BASE COAT AND FINESTONE REINFORCING MESH

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING • MESH• FINESTONE FINISH COAT

Page 13: Pebbletex Adhered Mat Design - BASF

0616

AM-19 TYPICAL CORNER MESH APPLICATION WITH STRONG 15 OR HI-IMPACT 20 (PLAN VIEW)

AM-20 TYPICAL CORNER MESH APPLICATION WITH STANDARD MESH, INTERMEDIATE 6 OR 12 (PLAN VIEW)

ACCEPTABLE SHEATHINGFRAMING

FINESTONE BASE COAT

CORNER MESH EMBEDDED IN BASE COAT

STANDARD MESH REINFORCING MESH OR INTERMEDIATE 6 EMBEDDED IN FINESTONE BASE COAT

STRONG 15 OR HI-IMPACT 20 EMBEDDED IN FINESTONE BASE COAT

FINESTONE INSULATION BOARDPERMALATH 1000 OR METAL LATH

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA

NOTE: • BUTT EDGE OF STRONG 15 OR HI-IMPACT 20 TO CORNER MESH• A CONTINUOUS OVERLAY OF STANDARD MESH OR INTERMEDIATE 6 IS REQUIRED OVER STRONG 15, HI-IMPACT 20 OR CORNER MESH.

ACCEPTABLE SHEATHINGFRAMING

FINESTONE BASE COAT

CORNER MESH EMBEDDED IN BASE COAT

STANDARD MESH REINFORCING MESH OR INTERMEDIATE 6 EMBEDDED IN FINESTONE BASE COAT

FINESTONE INSULATION BOARD

PERMALATH 1000 OR METAL LATH

FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA

NOTE: A CONTINUOUS OVERLAY OF STANDARD MESH OR INTERMEDIATE 6 OR 12 IS REQUIRED OVER CORNER MESH.

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING • MESH• FINESTONE FINISH COAT

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

Page 14: Pebbletex Adhered Mat Design - BASF

0616

Pebbletex® Adhered Mat Design

AM-21 TYPICAL LIGHT FIXTURE

AM-22 TYPICAL TERMINATION AT FOUNDATION

ACCEPTABLE SHEATHING

FRAMING

FOUNDATION

FLASHING

FINESTONE BASE COAT

ACCEPTABLE SHEATHING

PERMALATH 1000 OR METAL LATH

FRAMING

WIRE OPENING

FINESTONE BASE COAT

SET FLANGE IN SEALANT

SMALL LIGHT FIXTURE

FINESTONE INSULATION BOARD

FINESTONE INSULATION BOARD

SEALANT

PERMALATH 1000 OR METAL LATH

FINESTOPTM, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

WRAP BASE COAT AND FINESTONE REINFORCING MESH

FINESTOPTM, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

SELF-ADHERING MESH TAPE (4”), 4” SHEATHING FABRIC OR BASF WS FLASH

WRAP BASE COAT AND FINESTONE REINFORCING MESH

NOTE: • IF SECONDARY MOISTURE PROTECTION BARRIER IS

USED IN LIEU OF FINESTOP OR FINESTOP RA, ENSURE BARRIER IS PROPERLY LAPPED OVER THE FLASHING FLANGE.

• TERMINATE PEBBLETEX ADHERED MAT DESIGN SYSTEM MIN. 203 mm (8”) ABOVE GRADE.

MIN. 50 mm (2”)MAX. 305 mm (12”)

Page 15: Pebbletex Adhered Mat Design - BASF

0616

AM-23 TYPICAL TERMINATION AT FOUNDATION (FLUSH)

ACCEPTABLE SHEATHING

FRAMING

FOUNDATION

FINESTONE INSULATION BOARD

PERMALATH 1000 OR METAL LATH

BACKER ROD, SEALANTAND WEEP TUBE

BASF COLOR COATMIN. 25 mm (1”)

FINESTONE BASE COAT

BASF WS FLASH

AM-24 TYPICAL KICK-OUT FLASHING DETAIL

ACCEPTABLE SHEATHING

PEBBLETEX ADHERED MAT DESIGN

STEP FLASHING

BACKER ROD AND SEALANT

ROOF SHINGLES

BUILDING PAPER

DRIP EDGE

KICK-OUT FLASHING

MIN. 100 mm (4”)

MIN. 50 mm (2”)

FINESTOPTM, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

WRAP BASE COAT AND FINESTONE REINFORCING MESH

FINESTOPTM, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER

FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT

NOTE: • KICK-OUT FLASHING MUST BE ANGLED 100˚ MIN.TO ALLOW FOR PROPER DRAINAGE.• KICK-OUT FLASHING SEAMS MUST BE SOLDERED OR SEALED WITH APPROPRIATE SEALANT.• TERMINATE PEBBLETEX ADHERED MAT DESIGN MIN. 50 mm (2”) ABOVE ROOF.

Page 16: Pebbletex Adhered Mat Design - BASF

BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.finestone.basf.com© 2016 BASF Corporation rev 160622

For the most current version of this literature, please visit our website at www.finestone.basf.com.

Pebbletex® Adhered Mat Design