30
Performances of large Pixelized Micromegas detectors in the COMPASS environment Florian Thibaud CEA Saclay – Irfu/SPhN MPGD 2013 Conference July 1 st 2013 Zaragoza

Performances of large Pixelized Micromegas detectors in the COMPASS environment

Embed Size (px)

DESCRIPTION

Performances of large Pixelized Micromegas detectors in the COMPASS environment. Florian Thibaud CEA Saclay – Irfu / SPhN. MPGD 2013 Conference July 1 st 2013 Zaragoza. Outline. The COMPASS Experiment at CERN The Pixel Micromegas Detector Motivations - PowerPoint PPT Presentation

Citation preview

Performances of large Pixelized Micromegas detectors in the COMPASS environment

Florian ThibaudCEA Saclay – Irfu/SPhN

MPGD 2013 Conference

July 1st 2013Zaragoza

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 2

Outline

The COMPASS Experiment at CERN The Pixel Micromegas Detector

Motivations Discharge reduction technologies Large size detectors readout Front-end electronics

Performance of Pixel Micromegas in the COMPASS spectrometer Discharge rate Efficiency Spatial resolution Time resolution

Pixel Micromegas and track reconstruction Conclusion Outlook

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 3

Target

Dipole SM1

Dipole SM2

2nd spectrometer

1st spectrometer

µ/h 160-200

GeV

Φ = 105 -107 /s

~50 m

The COMPASS experiment at CERN

COmmon Muon Proton Apparatus for Structure and Spectroscopy High resolution spectrometer Very good spatial resolution (<100µm) required at

small angle for kinematics and particle identification One of the first experiments to use GEM and

Micromegas detectors

Micromegas Detectors Very high flux Magnetic field(s)

SPS

LHC

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 4

The Pixel Micromegas Project : motivations

Pixel Micromegas Project 10 to 100 times fewer discharges compared to present Micromegas Read-out with pixels in the beam area

40 cm

1024

ch

anne

ls

Present COMPASS Micromegas detectors : good performances but room for improvements : Blind center (5 cm diameter disk, beam area) Discharges in hadron beam (0.1 discharge/s)

COMPASS II plans for 2015 :• Hadron beam up to 107 hadrons/s

Need for a spark protected detector

• Better tracking in the beam area Need for a detector with active center

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 5

Discharge reduction technologies

2 solutions investigated :

140 µm

70 µm

• Detector with resistive pads and buried resistors Quick rise of the resistive pads’ potential Limitation of the discharge amplitude Compatible with a pixelized readout

• Preamplification stage with a GEM foil Gain shared between amplification

gap and GEM foil Diffusion of the primary electron cloud

Design by Rui de Oliveira et al.

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 6

Large size detectors : readout

Nominal design after 3 years of development 40 x 40 cm2 active area 2560 readout channels

1280 strips 768 of 400 μm x 20 cm (center) 512 of 480 μm x 40 cm (edges)

1280 rectangular pixels 640 of 400 μm x 2.5 mm 640 of 400 μm x 6.25 mm

Active area

25 mm50 mm

2.5x0.4 mm²

6.25x0.4 mm²

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 7

Large size detectors : front-end electronics

APV card Preamplification / shaping

ADC board Analog to digital conversion

HGeSiCA board Data concentrator Trigger distribution

Chain designed for

COMPASS GEM and Silicon detectors by TUM

APV chip

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 8

Large size detectors

2012 : Pixel Micromegas are included in COMPASS 2 detectors with GEM foil (+1 spare) replace 2 standard Micromegas detectors 1 prototype with Buried Resistors is tested in hadron beam All detectors participate to the physics data taking Spark resistant Micromegas detectors used as trackers at a flux

up to 650kHz/cm2 for the 1st time in a physics experiment

PMM_2012.1 - GEM

PMM_2011.2 - GEM PMM_2011.3 - BR

Target

Dipole

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 9

Discharges No discharge observed in nominal flux hadron beam on all PMM detectors

I mes

h (n

A)

I mes

h (n

A)

PMM_2012.1 - GEM PMM_2011.2 - GEM

I mes

h (n

A)

I mes

h (n

A)

300

0 20 40

0 20 40 0 20 40

0 20 40Time (min) Time (min)

Time (min) Time (min)

DischargesStandard MM with reduced gain

PMM_2011.3 - Buried Resistors

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 10

Large size detectors : data reconstruction

Ratio a1/a2 used for time reconstruction

a0

a2

a1

triggersynchronized

trigger

TCS phase

APV : 3 amplitudes samples spaced by 75 ns at each trigger A

mp.

[AD

C u

nits

]

Time [ns]0 100 200 300 400 500 600 700 800

latency

a2

xhitx1 x2 x3 x4 x5

a 1/a

2

TCS phase [ns] Hit time [ns]

Sample a2 used for position reconstruction

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 11

Efficiency (Φ=9x105 s-1)

PMM_2012.1 - GEM PMM_2011.3 - BRPMM_2011.1 - GEM PMM_2011.2 - GEM

Long strips disconnected40 cm

40 c

m

2.5 cm5 cm

ε = 98.2 % ε = 97.8 % ε = 97.8 % ε = 98.0 %

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 12

EfficiencyPMM_2011.1

GEM µ+

Φ=9x105 s-1

µ-

Φ=2x107 s-1

µ+

Φ=5x107 s-1

Pixels 97.9% 97.1% 95.7%

Strips 97.8% 97.4% 97.0%

Global 97.8% 97.2% 96.3%

PMM_2011.2GEM

µ+

Φ=9x105 s-1

µ-

Φ=2x107 s-1

µ+

Φ=5x107 s-1

Pixels 97.7% 97.3% 96.9%

Strips 98.4% 88.7%* 86.7%*

Global 97.8% 93.8% 92.3%

PMM_2012.1GEM

µ+

Φ=9x105 s-1

µ-

Φ=2x107 s-1

µ+

Φ=5x107 s-1

Pixels 98.4% 98.0% 96.8%

Strips 97.8% 97.0% 97.0%

Global 98.2% 97.6% 96.9%

PMM_2011.3BR

µ+

Φ=9x105 s-1

µ-

Φ=2x107 s-1

µ+

Φ=5x107 s-1

Pixels 97.9% Not tested Not tested

Strips 98.1% Not tested Not tested

Global 98.0% Not tested Not tested

Efficiency > 95% for all detectors in all conditions

Slight decrease at highest flux : Pixels : ~ 1.5% Strips : < 1%

*missing front-end card

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 13

Spatial Resolution Residual plots with low flux and field off Dectector resolution :

Pixels

σres = 61 µm

σdet = 56 µm

Strips

σres = 72 µm

σdet = 57 µm

PMM_2011.2 - GEM PMM_2011.3 - BR MM02X (standard Micromegas)

σPMM+GEM < σstandard MM

σPMM+BR >~ σstandard MM

Strips

σres = 85 µm

σdet = 78 µm

Pixels

σres = 76 µm

σdet = 69 µm

Strips

σres = 79 µm

σdet = 71 µm

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 14

Spatial Resolution : influence of the dipole field

Dipole fringe field up to 0.2 T at the prototype position

Detector

µ+

Φ=9x105 s-1

Dip. OFF(µm)

µ+

Φ=9x105 s-1

Dip. ON(µm)

PMM_2011.2GEM

(strips)57 56

PMM_2011.2GEM

(pixels)56 58

PMM_2011.3 BR

(strips)78 119

PMM_2011.3 BR

(pixels)69 111

MM02X(standard

Micromegas)71 104

Far from dipole No effect

Close to dipole Degradation (~ +50%)

similar for standard MM and PMM_2011.BR

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 15

Spatial Resolution : influence of the beam flux

Detectorµ+

Φ=9x105 s-1

(µm)

µ+

Φ=4x106 s-1

(µm)

µ-

Φ=2x107 s-1

(µm)

µ+

Φ=5x107 s-1

(µm)

MM01U (standard

Micromegas)65 67 71 74

PMM_2011.2 GEM

(strips)56 57 68 72

PMM_2011.2 GEM

(pixels)57 57 79 87

PMM_2011.3 BR

(strips)119 139 Not tested Not tested

PMM_2011.3 BR

(pixels)111 127 Not tested Not tested

MM02X(standard

Micromegas)104 107 Not tested Not tested

PMM + GEM

Strips : Degradation comparable to

standard MM (~10-15%)

Pixels : Degradation (~50%) at the

highest flux but still < 90µm (preliminary result*)

PMM w/ BR Degradation worse than

standard MM in the same region (25% compared to 3%)

Close to dipole

PRELIMINARY* PRELIMINARY*

*Lack of redundancy at small angle

Poor tracking resolution

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 16

Time Resolution : Gas Mixture

σ = 8.7 ns

σ = 9.1 ns

Strips

Pixels

PMM_2011.2 - GEM

Cluster time [ns]

Cluster time [ns]

σ = 13.3 ns Strips

Cluster time [ns]

σ1 = 13.2 ns Pixels

Cluster time [ns]

Muon run : 80% Ne + 10% C2H6 + 10% CF4 Hadron run : 85% Ne + 10% C2H6 + 5% CF4

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 17

Time Resolution : GEM vs BR

σ = 13.3 ns

σ = 13.2 ns

RMS = 29.9 ns

RMS = 32.1 ns

PMM_2011.3 - BRPMM_2011.2 - GEM

StripsStrips

Pixels Pixels

Cluster time [ns]

Cluster time [ns]

Cluster time [ns]

Cluster time [ns]

Hadron run : 85% Ne + 10% C2H6 + 5% CF4

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 18

Time Resolution

Summary of time resolution measurements (in ns)

DetectorPMM_2011.1

GEM(strips)

PMM_2011.1GEM

(pixels)

PMM_2011.2GEM

(strips)

PMM_2011.2GEM

(pixels)

PMM_2012.1GEM

(strips)

PMM_2012.1GEM

(pixels)

PMM_2011.3BR

(strips)

PMM_2011.3BR

(pixels)

Standard Micromegas

µ+

Φ=5x107 s-

1

8.8 9.7 8.7 9.1 12.4* 10.3*Not

testedNot

tested9.3

π -, K-

Φ=4x106 s-

1

Not tested

Not tested

13.3 13.2 13.3 13.0 29.9 32.1 12.6

σPMM+GEM ~ σMM

σPMM+BR ~ 2.5 x σPMM+GEM

*due to PCB curvature

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 19

High flux muon run (5x107 s-1): 2 PMM+GEM integrated in the tracking (BR off beam) Difficult conditions for track reconstruction in the beam area :

Beam flux up to 650 kHz/cm2

Only 5 planes between target and dipole -> PMMs = 40% of the trackers

Necessity for precise time cuts on PMM to reduce combinatorial background

Pixel Micromegas and track reconstruction

Reconstructed time [ns]Reconstructed time [ns]

Non flat background due to time reconstruction from amplitudes

(Not physical)

Clusters close to a track (Pixelized area)All clusters (Pixelized area)

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 20

Time Cuts

PMM.2011.2GEM

Pixel Plane

Number of clusters

(reduction)

Efficiency Background probability

No Cuts 2145513 95.7% 11%

Cut on cluster time (-

30ns<t<40ns)

634167(-70 %)

93.6% 2.9%

Amount of clusters on the pixelized area in the highest beam flux (650 kHz/cm2)

Clusters : -70% Small loss in efficiency (<2%) Important decrease of background probability

-30 40

-30 40

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 21

Impact of Time Cuts on the track reconstruction

µ+

Φ=5x107 s-1

650 kHz/cm2

Number of tracks > 1000(% of #events)

Number of combinations > 20000(% of #events)

No Cuts 29.8% 0.5%

Cut on cluster time (-30ns<t<40ns) 3.1% 0.1%

Observable : Amount of events with too many tracks or combinations generated by the COMPASS reconstruction software in the zone between the target and the first dipole

Rejected events : -90% Reduction of the combinatorial background

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 22

Conclusion

Micromegas detectors used as trackers in a flux up to 650kHz/cm2 for the 1st time in a physics experiment

2 spark-protection technologies used, no spark observed in nominal intensity hadron beam.

Efficiency : low flux >98%; high flux > 95%

Spatial resolution : PMM+GEM :

Better than standard COMPASS MM (55-60µm vs 65-70µm) Flux : degradation at 600 kHz/cm2 comparable to standard COMPASS Micromegas

PMM w/ BR : Comparable to standard COMPASS MM (~70-80µm) Flux : degradation more important than standard MM

Time resolution : PMM+GEM : ~9-10 ns (10% CF4), ~13 ns (5% CF4)

PMM w/ BR : ~30 ns (5% CF4)

Tracking : cut on cluster time (-30ns to 40ns) : -90% rejected events

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 23

Outlook

Choice GEM/BR : a priori GEM due to better performance, but studies on BR still ongoing.

Production : final detectors will be produced by the CIREA-ELVIA company (see talk by Damien NEYRET during RD51 meeting).

Complete installation : replacement of the 12 standard Micromegas by Pixel Micromegas foreseen for the COMPASS II run in early 2015.

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 24

Backup Slides

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 25

PMM + GEM : gain & efficiency

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 26

PMM BR : gain

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 27

Efficiency : hadron beam

MP01X Eff. High Fluxhadrons

Pixels 96.5%

Strips 97.0%

Global 96.6%

MP01Y Eff. High Fluxhadrons

Pixels 96.3%

Strips 97.0%

Global 96.3%

MP00 Eff. High Fluxhadrons

Pixels 96.5%

Strips 96.7%

Global 96.7%

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 28

Time Resolution vs position

σ = 8.7 ns

σ = 12.4ns

σ = 9.1 ns

σ = 10.3 ns Strips

Strips Pixels

Pixels

PMM_2012.1 (PixelMM w/ GEM)

PMM_2011.2 (PixelMM w/ GEM)Mean cluster time vs position

Mean cluster time vs position

Cluster time [ns]Cluster time [ns]

Cluster time [ns]Cluster time [ns]

Y [

cm]

Larger σ due to detector curvature

X [cm]

X [cm]

Y [

cm]

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 29

Pixel Micromegas and track reconstruction

Reconstructed time [ns]

All clusters (Pixelized area)All clusters (Pixelized area)

a 1/a

2

TCS phase [ns]

Florian Thibaud – CEA Saclay - Irfu - SPhN – July 2013 – 30

Impact of Time Cuts on the track reconstruction

µ+

PMM_2011.2 - GEMPixel Plane

~22500 events

#tracks/event(between target

and SM1)

%events w/ primary vertex(#tracks/vertex

)

No Cuts 1.47 41.7(2.132)

Cut on cluster time (-30ns<t<40ns) 1.54 43.2(2.135)

+ 5% + 4%