5
Page 1,of 5 UQ-POWER DIESEL GENERATOR Powered by Kubota Model:KE15Tier 4 Photo above for illustration purposes only kW/kVA 15.0 kW/kVA 12 kW/kVA 16 Hz/rpm 60 18.0 15 20 1800 V 208 120 A / / mm kg mm kg GENERAL DATAPrime Power Frequency Voltage Current Connection Rated Power Factor Open TypeL×W×HOpen Type(Weight) Silent TypeL×W×HSilent Type(Weight) 42 3P 4W Series 0.8pf 1300×800×11 90 410 2000x950x120 0 730 Available in the following voltages 120/208, 277/480, 120/240( both single and three phase) All data based on ISO 3046, altitude 1000m (361ft), barometric pressure 100kPa (29.53inHg), air temperature 25 (77° F), relative humidity 30%. Please contact UQ-Power for correct generator capacity selection when the load application can't meet with the standard reference. UQ-Power diesel generators comply with standards ISO8528ISO 14000ISO3046GB755BS5000VDE0530, ISO3046IEC34-1 All data is subject to change without notice. Countinueous Stand by

Photo above for illustration purposes only

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Photo above for illustration purposes only

Page 1,of 5

UQ-POWER DIESEL

GENERATOR Powered by Kubota

Model:KE15Tier 4

Photo above for illustration purposes only

kW/kVA 15.0

kW/kVA 12

kW/kVA 16

Hz/rpm 60

18.0

15

20

1800

V 208 120

A

/

/

mm

kg

mm

kg

GENERAL

DATAPrime Power

Frequency

Voltage

Current

Connection

Rated Power Factor

Open Type(L×W×H)

Open Type(Weight)

Silent Type(L×W×H)

Silent Type(Weight)

42

3P 4W Series

0.8pf

1300×800×11

90 410

2000x950x120

0 730

■ Available in the following voltages 120/208, 277/480, 120/240( both single and three phase)■ All data based on ISO 3046, altitude 1000m (361ft), barometric pressure 100kPa (29.53inHg), air temperature 25 ℃(77°F), relative humidity 30%.

■ Please contact UQ-Power for correct generator capacity selection when the load application can't meet with the standardreference.■ UQ-Power diesel generators comply with standards ISO8528,ISO 14000,ISO3046,GB755,BS5000,VDE0530,ISO3046,IEC34-1

All data is subject to change without notice.

Countinueous

Stand by

Page 2: Photo above for illustration purposes only

All data is subject to change without notice.. Page 2,of 5

Engine accessories ◇ Heavy-duty air filter ◇Coolant heater ◇Lub oil heater ◇Fuel and Water Separator

◇50℃ radiator ◇Heat exchanger + water cooling tower + External water circulation pumpingsystem

◇Remote horizontal water tank system

◇Other(Comap controls inc)

◇2, 3 and 4 pole, thermo-magnetic

◇ATS- available in Nema 1 and 3R, 2 and 3 pole

◇Single wall and double wall tank available in 8, 12, and24 hour sizes

www. u

q-po

wer.com

Engine

Alternator

Radiator

Base frame

Circuit Breaker Engine

Control System Start

Battery

Exhaust System

Documents

Cooling system

Control System

Circuit Breaker

Automatic Transfer Switch

Optional Fuel Tank

.

Brand new Kubota Diesel Engine, to include air filter,

fuel filters, oil filter, starting motor and charging

T AS

Alternator YANAN SLG brushless AC alternator with Yanan YN-440 AVR

50℃, fan with protective shroud

Base mounted fuel tank, fuel meter, rubber anti-vibration pads, battery holder ≥500KW: channel steel base frame

Molded case circuit breaker (MCCB) ABB-UL listed

DEEP SEA 6020

Lead-acid battery, connection cables.

Flex exhaust, Elbow and flange, Exhaust silencer, etc.

UQ-Power standard,Mechanical drawing, electric drawing, operation & maintenance manual,

certification etc.

NDARD

CONFIGURATION

Standard Unit Configuration

Optional available Equipment

Page 3: Photo above for illustration purposes only

All data is subject to change without notice. Page 3,of 5

18.1 kW

1.647 L

87×92.4 mm

23:1

1800 RPM

5.1 l/h

D1503-M-BG

Naturally Aspirated Vertical

in line 3

Electric Governor

4.7 l/h No.2-

D(ASTMD975) Bosch Type

■ Lubrication System

7 L NA l/h

CF 121 ℃

■ Coolant System

15 L 110 ℃

71 ℃ Shaft drive

■ Air Intake System

1.29 m3/min ≦ 1.96 kPa

■ Exhaust System

3.48 m3/min 7.07 kPa

■ Starting System

Electric start 80 Ah

ENGINE DATA Engine

Model

Aspiration Type

No. of Cylinders

Governor Type

■ FuelSystem ■ Prime power Fuelconsumption

Fuel #

Lub Oil Capacity

Lub #

Coolant Capacity

Std. Thermostat (Modulating) Range

Air intcke capacity

Exhaust Gas Flow

Start Mode

Engine power

Displacement

Bore×Stroke

Compression Ratio

Rated Speed

Standby power Fuel consumption

Injection System

Lub Oil Consumption

Max.Temperature

Max. Top Tank Temp.

Fan Drive Type

Air Pressure

Max.Back Pressure

Battery

www.uq-po

wer.com

Page 4: Photo above for illustration purposes only

All data is subject to change without notice. Page 4,of 5

ALTERNATOR DATA14/17.5 kW/kVA

208/120 V

60 Hz

CONTROL SYSTEM DATA MODEL DSE6020

■ Control Panel features

Electronic J1939 (CAN) and Modbus capable. MPU and alternator

sensing engine support for diesel,and gas engines all in one

controller. With a large number of flexible inputs, outputs and

protection circuits.

The modules can be easily adapted to suit a wide range of

applications.

■ Key Functions

▲Configurable remote start input▲utility voltage sensing

▲Generator/load power monitoring

▲Configurable staged loading

▲CAN, MPU and alternator

(kW, kV A, kV Ar, pf) speed sensing in one variant

▲alternative configuration

▲alarm including common alarm,common

▲Generator overload protection (kW) ▲3 engine maintenancealarms

electric and common shutdown

▲Efficient power save mode

▲mains and generator closed viafront panel

▲LCD and LED alarmindication

▲Configurable event log (50)

▲Heated display optionavailable

☆For more information, please visit the

▲4 configurable DC outputs

▲4 configurable analog./digitali nputs&s topping Deep Sea Controls website

▲6 configurable digital inputs

▲Support for 0-10 V & 4-20 mA oilpressure sensors

▲engine speed protection

▲Engine pre-heat

▲Multiple date and time scheduler

▲Engine idle control for starting

▲Fuel pump control

▲Battery voltage monitoring

▲Start on low battery voltage output

Single Bearing

IP21

80.70%

±1.0%

YN440

Alternator Model

PF.

Phase

Connection

Winding Pitch

Insulation Class

Tel. Influence

Harmonic

Coefficient Voltage

Adjust Scope

Yanan SLG164C

0.8

3

3P 4W,Y

connection 2/3

H/H

TIF:<50

THF:<2%

≥±5%

Rate Power

Voltage

Frequency

Bearing

Proteccion

Class

Efficiency

Voltage

Regulation AVR

Excitation

System

Self-excited

www.uq-po

wer.com

Page 5: Photo above for illustration purposes only

All data is subject to change without notice, sorry for inform.

Page 5,of 5

WARRANTY POLICY

1.Standard warranty for one year or 1000 hours ( whichever comes first) from sales date.

Refer to

《UQ-Power Diesel Generator Warranty Manual》 for more details.

2.Maintenance parts( filters, belts,hoses, batteries),improper operation and maintenance

failures are excluded from the warranty policy

Ⅷ . DRAWING (for illustration purposes only)