Upload
others
View
18
Download
0
Embed Size (px)
Citation preview
2925
2675
3945
9545
2925
2675
3945
9545
2450
2700
11400
2925
2675
3945
9545
2925
2675
3945
9545
11150
2925
2675
3945
9545
HOUSE TYPE B2HOUSE TYPE B3
4400
WC
ST.
2.7 m²
5025
3500
Kitchen/Dining
18.1 m²
HOUSE TYPE B2
5575
HALL
LIVING ROOM
20.8 m²
5025
LIVING ROOM
16.2 m²
4400
WC
ST.
2.7 m²
5025
3500
Kitchen/Dining
18.1 m²
HOUSE TYPE B3
5575
1125
HALL
3800
BATH
4400
ST.
1.3 m²
3250
2200
HOUSE TYPE B2
5575
BEDROOM 3
7.5m²
2125
3670
BEDROOM 1
15.7m²
Attic
Hatch
2800
BEDROOM 2
11.4m²
1675
1900
E/S
3530
2975
BATH
4400
ST.
0.7 m²
3525
4200
HOUSE TYPE B3
5575
BEDROOM 3
7.5m²
2125
3670
BEDROOM 1
14.4m²
E/S
2800
BEDROOM 2
11.4m²
Attic
Hatch
Folding attic
stairs to provide
access to attic
storage area
3.5m2
HOUSE TYPE B3HOUSE TYPE B2
Obscure
Glazing
Indicitive Solar Panel Position, Final Solar Panel Position Depends
on House Orientation.
The solar panels shown are a provisional option to satisfy
renewable energy requirements of building regs part L. Solar panels
may be omitted in favour of alternative renewable energy source.
FRONT ELEVATION B3-B2 (SEMI-DETACHED)
Ground
Floor Level
+0.000
First Floor Level
+2.925
Attic Storage Level
+5.600
Ridge Level
+9.545
Ground
Floor Level
+0.000
First Floor Level
+2.925
Attic Storage Level
+5.600
Ridge Level
+9.545
KITCHEN/DINING
TOILET
LIVING ROOM
ATTIC STORAGE
BED 2 HALL BED 1
SECTION A-A
Ground
Floor Level
+0.000
First Floor Level
+2.925
Attic Storage Level
+5.600
Ridge Level
+9.545
Ground
Floor Level
+0.000
First Floor Level
+2.925
Attic Storage Level
+5.600
Ridge Level
+9.545
GROUND FLOOR PLAN B3-B2 (SEMI-DETACHED)
AREA B2 = 53.7m², AREA B3 = 52.5m²
OA B2 = 107.4m² / 1156sq.ft, OA AREA B3 = 106.2m² / 1143sq.ft
FIRST FLOOR PLAN B3-B2 (SEMI-DETACHED)
AREA B3/B2 = 53.7m²
REAR ELEVATION B3-B2 (SEMI-DETACHED)
Obscure
Glazing
SIDE ELEVATION - House Type B2
Ground
Floor Level
+0.000
First Floor Level
+2.925
Attic Storage Level
+5.600
Ridge Level
+9.545
Obscure
Glazing
SIDE ELEVATION - House Type B3
s
u
b
s
u
b
s
u
b
s
u
b
s
u
b
s
u
b
s
u
b
s
u
b
s
u
b
s
u
b
s
u
b
sub
SW/A1
.011
s
u
b
s
u
b
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
B
U
S
B
U
S
B
U
S
B
U
S
STOP
STOP
STOP
STOP
STOP
STOP
REVISIONS
DATE DESCRIPTIONNo.
NOTES:
DO NOT SCALE FROM
DRAWINGS. WORK TO
FIGURED DIMENSIONS
ONLY. ARCHITECT TO
BE NOTIFIED OF ALL
DISCREPANCIES.
DRAWING TITLE:
PROJECT TITLE:DATE:
DRAWN BY:
SCALE: REVISION:
JOB NO: DRAWING NO:
M CROSSAN O ROURKE MANNING
cARCHITECTS
M C
1 Grantham Street, Dublin 8, D08 A49Y, Ireland.
Tel: 01-4788700 Fax: 01-4788711 E-Mail: [email protected]
HOUSE TYPE B2/B3
Plans, Sections & Elevations
Coosan, Athlone
A1:100
CLMay'20
18029 PL06
TYPE B3/B2 - 3 BED - SEMI-DETACHED
TY
PE
B
3/B
2 - 3 B
ED
- S
EM
I-D
ET
AC
HE
D
N
HOUSE TYPE
2 STOREY
B2
BED 3
Semi-Detached
SQM /107.4 SQF1156
B2
THIS DRAWING TO BE READ IN CONJUNCTION WITH ARCHITECT'S DRAWINGS,
CONSULTANT ENGINEER'S DRAWINGS AND SPECIFICATIONS & LANDSCAPE
ARCHITECTS DRAWINGS
REFER TO ARCHITECT'S SITE PLAN PL02 FOR NORTH ORIENTATION.
LEVELS GIVEN ON HOUSE TYPE DRAWINGS ARE GIVEN TO A LOCAL ABSOLUTE
ZERO LEVEL. FOR SPECIFIC LEVELS DEPENDING ON INDIVIDUAL UNIT
LOCATION, REFER TO ARCHITECT'S CONTEXT SECTIONS AND ENGINEER'S
DRAWINGS WHERE LEVELS ARE ARE ALL GIVEN IN RELATION TO LAND
SURVEYOR'S BENCHMARK BASED ON MALIN HEAD DATUM LEVEL.
ROOF : TO BE FINISHED IN SLATE OR CONCRETE ROOF TILES IN
SELECTED COLOUR OR SIMILAR APPROVED.
WALLS : SELECTED CLAY BRICKWORK WHERE INDICATED OTHERWISE
PAINTED SAND / CEMENT RENDER OR SELF COLOURED
RENDER. EXPRESSED BANDS AROUND EXTERNAL OPES/
EXPRESSED LINTOLS OVER EXTERNAL OPES WHERE
INDICATED TO BE RECONSTITUTED STONE (LIGHT CREAM
LIMESTONE OR GRANITE EFFECT) OR RENDER
JOINERY : ALL WINDOWS AND DOORS, FRAMES AND LEAVES, TO BE
ALUMINIUM POWDER-COATED TO APPROVED COLOUR
OR uPVC.
OBSCURE GLAZING WHERE INDICATED TO SENSITIVE
WINDOWS.
RAINWATER GOODS : GUTTERS, DOWNPIPES, AND FIXINGS TO BE uPVC OR
ALUMINIUM POWDER COATED TO SELECTED COLOUR TO
MATCH ROOF SLATES
G E N E R A L N O T E S
N O T E S O N F I N I S H E S :
SOLAR PANELS: INDICATIVE SOLAR PANEL POSITION, FINAL SOLAR PANEL
POSITION DEPENDS ON HOUSE ORIENTATION. THE SOLAR
PANELS SHOWN ARE A PROVISIONAL OPTION TO SATISFY
RENEWABLE ENERGY REQUIREMENTS OF BUILDING REGS
PART L. SOLAR PANELS MAY BE OMITTED IN FAVOUR OF
ALTERNATIVE RENEWABLE ENERGY SOURCE.
*
HOUSE TYPE
2 STOREY
B3
BED 3
Semi-Detached
SQM /106.2 SQF1143
B3
Side Entrance
KEY PLAN
Scale - 1:2500
30-3-20 General update for planning A