Upload
others
View
21
Download
0
Embed Size (px)
Citation preview
Subject to Change Without No�ce
HAWKHAWKENTERPRISESENTERPRISES
HAWK ENTERPRISES 2902 Park Six Court, Elkhart, IN 46514 (574) 294-1910 www.hawkenterprises.com
HAWK AS 500 HEPA Air ScrubberHAWK AS 500 HEPA Air Scrubber250-500 Variable CFM250-500 Variable CFM
AS 500 HEPA Air Scrubber
Model AS 500 HEPAMotor Rating 0.33 HPPower 115v/60 HzCurrent 2.5 AmpsCFM 250-500Weight 39 lbs.Dimensions 22”x13”x19.5”Certifications C-ETL-USFilter Size 16” x 16”Pre-Filter G4 Pleated - 1”HEPA Filter H13 - 2”Optional Filter Activated CarbonColor Red
Op�onal Filter Ac�vated Carbon
Power 115v/60 Hz
Specifica�ons
Motor Ra�ng 0.33 HPModel AS 500 HEPA
Current 2.5 AmpsCFM 250-500
Dimensions 22”x13”x19.5”Filter Size 16” x 16”
Weight 39 lbs.
HEPA Filter H13 - 2” Pre-Filter G4 Pleated - 1”
Pre-Filter
Pre-Filter
HEPA Filter
CarbonFilter(optional)
Pre-Filter
C
VarialSpeedControlCircuit
BreakerCord Plugin for Daisy ChainConnections
AirIntake
CleanedAirExhaust
DAYS 1 thru 15 A unit that fails within the first 15 days a�er the sale to an end-user may be eligible to be replaced with a new unit at the sole discre�on of the manufacturer. All transporta�on costs will be covered for the customer.
The manufacturer warrants that goods sold to the original user shall be free from defects in material and workmanship as follows:
6. Reimbursement for warrantable replacement parts not supplied by the manufacturer.7. Shipping damage, or damage as a result of abuse in transpor�ng the unit. The manufacturer does not warrant that
All other warran�es, guaran�es, or representa�ons, express or implied, by opera�on of law or otherwise, are expressly disclaimed. If circumstance warrants, the manufacturer may opt to refund the purchase price of such goods. Where applicable, as indicated above, the manufacturer will pay return transporta�on charges on returned goods not exceeding the transporta�on charges applicable to ship from original des�na�on unless the returned goods are free from defect and conform to specifica�ons. Be sure to review this instruc�on booklet. Returned goods which are found by the manufacturer to be free from defect and to conform to specifica�ons shall be held for Purchaser’s shipping instruc�ons, which shall be furnished promptly upon request.
Any replacement parts supplied under warranty will be warranted for the balance of the product’s warranty.. Establishing the proof of purchase date for warranty purposes is the responsibility of the end-use customer, failing which, the effec�ve date will be based upon the date of manufacture plus thirty (30) days. Retain your bill of sale as proof of purchase.
Limited Manufacturer’s Warranty
1-year parts and labor on the en�re unit.
HAWK will not be responsible for:
2. Damage due to failure to perform normal maintenance as outlined in the Instruc�on Manual.
inadequacy or interrup�on of electrical services.4. Damage or repairs needed as a consequence of any misapplica�on, abuse, neglect, unauthorized altera�on,
the unit ra�ng plate.
other condi�ons beyond the control of the manufacturer.
For warranty informa�on and assistance contact Hawk Enterprises at (574) 294-1910 or email [email protected]
DAYS 16 thru 1 Year. A unit that fails between 15 and 365 days a�er sale will have parts and labor charges covered under warranty, but transporta�on charges are to be paid by the customer. Transporta�on costs include travel charges by repair personnel, or shipping charges to move the unit to and from a repair loca�on.
1. Useful filter life / replacement filters.
3. Failure to start due to voltage condi�ons, blown fuses, open circuit breakers, or any other damages due to the
improper servicing, or opera�on, including opera�on outside the voltage and frequency limita�ons as stated on
5. Damage as a result of flooding (immersion), fires, lightning, freezing of residual water, corrosive environment, or
this sec�on.
The manufacturer’s liability shall in no event extend beyond replacement, repair or refund of the purchase price and shall not be liable under any circumstances for special, con�ngent, incidental or consequen�al damages, nor for losses, damages, or expenses directly or indirectly arising from the use of the goods, including without limita�on, warehousing, labor, handling and service charges, die, equipment, or machine breakage, nor for costs, lost profits or loss of good will. The use of subs�tute parts and/or filters in this product voids all warran�es and performance claims. The remedies set forth herein are exclusive.
the goods sold are merchantable or fit for any par�cular purpose, and makes warran�es other than as stated in
Unit Assembly
HAWK ENTERPRISES 2902 Park Six Court, Elkhart, IN 46514 (574) 294-1910 www.hawkenterprises.com
HAWK ENTERPRISES 2902 Park Six Court, Elkhart, IN 46514 (574) 294-1910 www.hawkenterprises.com
HAWKHAWKENTERPRISESENTERPRISES
Ÿ NEVER allow children to play around the AS 500.
Ÿ Store the AS 500 in clean, dry environment. Do not store outdoors. Do not allow water inside the unit’s motor. If the motor becomes wet, allow it to thoroughly dry before use.
Ÿ Operate the AS 500 on a flat surface. Do not operate where unit could fall, or on slippery surfaces. This increases the chance of injury, fire, or electrical shock.
Ÿ Do not move or carry the AS 500 while it is opera�ng. When opera�ng, the powerful airflow can cause unpredictable movement.
Ÿ Keep all liquids from being drawn into the AS 500. Never operate unit without factory installed safety inlet and outlet grills in place.
Ÿ Do not use the AS 500 near combus�ble gas, or hot air. Units could melt and cause a fire or electrical hazard.
Ÿ Do not alter or modify your AS 500 in any way.
Ÿ Unplug before service or changing filters.
The HAWK AS 500 HEPA Air Scrubber is a portable filtra�on system that removes airborne par�cles including mold, pet dander, dust, pollen, drywall dust, and other miscellaneous debris as small as 0.3 microns. The AS 500 u�lizes up to 3 stages of filtra�on including a pre-filter, op�onal 2nd stage, and a HEPA filter. The AS 500 will create cleaner air in any environment. The pre-filter and second stage filter capture larger par�cles and the HEPA filter captures smaller par�cles.
Ÿ Never use the AS 500 near water. Prevent risk of serious injury from electrical shock.
Ÿ Handle the AS 500 carefully to avoid causing damage or injury.
Ÿ Use only replacement parts authorized by Hawk Modifica�ons or use of unauthorized parts could create a hazard and will void your warranty.
Ÿ Do not stack more than 2 units high in order to avoid a �pping hazard – falling equipment can cause bodily harm.
Warnings!
Ÿ Make sure the air intake and outlet are free from all materials and away from obstruc�ons Any restric�ons may cause the AS 500 to overheat and cause a shock or fire hazard.
Ÿ Do not repair the AS 500 unless you are qualified.
qualified electrician or service person. Do not
the desired speed se�ng.
5. Operate unit un�l area is clear of unwanted contaminates or un�l filters need to be
1. Place the AS 500 upright on a level and stable
2. Remove the dust cover.
3. Plug the AS 500 into a grounded 115 volt
Opera�on
grounded outlet with the correct voltage and
protected by a ground fault circuit interrupter.
amperage. For maximum protec�on against
If you are unsure about the outlet, check with a
electrical shock, ALWAYS use a circuit that is
surface with the handle up.
use an adapter or extension cord.
4. To switch the unit on, locate the control panel and turn the variable speed switch clockwise to
Pre-Filter G4
Prime-Filter H13 (Made in Germany)
light which illuminates when the HEPA filter
changing filters.
changed. The control panel has a filter change
needs to be changed. See instruc�ons for
Auxiliary/GFCI Outlet/Daisy ChainYou can interconnect (“daisy-chain”) up to three AS 500 units to customize your air filtra�on needs. The GFCI will “trip” if it detects a sudden “ground fault,” or overload and interrupt the electric current. When the GFCI “trips,” unplug the unit and look for poten�al hazards such as standing water, frayed cords, or anything that would cause a dangerous electrical problem. If such a situa�on exists, plug the AS 500 into a different outlet and then push the “reset” bu�on which is located between the 2 outlets on the GFCI. If the unit will not operate check the circuit breaker sec�on below.
Power 115 Volts, 60 Hz
Current 2.5 amps
Air Flow 250-500 CFM
Unit Specifica�ons
Motor Ra�ng .33 hp
Cer�fica�ons C-ETL-US
grounded outlet
2) Open door by releasing sliding latches
Circuit Breaker Switch
Filters should be changed a�er every remedia�on job and whenever the filter change indicator light comes on. The unit should also be cleaned a�er each job to prevent cross-contamina�on.
AS 500 must be dry before installing clean filters.
1) Unplug the AS 500
outward, away from the AS 500 body.
The AS 500 is equipped with a circuit breaker switch to protect the motor. The switch is located directly above the GFCI outlet and cuts off power to the unit when it detects an unsafe amount of electricity passing through the unit. If the switch “trips,” unplug the unit and look for poten�al hazards or anything that may be crea�ng an overload situa�on. “Reset” breaker by pushing bu�on in and con�nue normal opera�on.
Changing FiltersWarning! Contaminated Hazard
To change filters:
3) Remove used filters and install new filters.4) Latch door closed and plug the unit in a
Always wear NIOSH compliant protec�ve gear when changing filters and dispose of used filters according to your local regula�ons.
• Circuit breaker or GFCI has tripped-push rest bu�onAS 500 does not turn on • Switch not turned on. Turn on.
Troubleshoo�ngProblem Problem Cause / Solu�on
• Excessive dirt built up on fan blade – wipe with a slightly damp cloth.
• No power to scrubber-make sure unit is plugged in; check power supply
AS 500 starts and then • Obstructed inlet/outlet – remove obstruc�on
• Damaged housing/fan so fan will not spin – replace housing or fan wheel
• Faulty switch-replace
Motor makes noises but won’t • Damaged/faulty motor or motor sha� – replace
shuts off • Faulty motor - replace
AS 500 vibrates • Motor sha� is bent – replace motor. Fan blade is bent – replace
• Air intake restricted – remove restric�on or bends/kinks induc�ng
turn on • Broken/loose wire to capacitor – �ghten
• Motor sha� set screw holding fan wheel is loose - �ghten
• Damaged/faulty capacitor – replace
AS 500 change light illuminated • HEPA filter needs replacement - replace
DO NOT OPERATE MACHINE IN AN EXPLOSIVE ENVIRONMENT!
Warning!
For the safe opera�on of this machine follow the instruc�ons given in this booklet and the training provided. Failure to do so can result in personal injury and/or damage to machine and property!
NOTE: In Canada, the use of a temporary adapter is not permi�ed by the Canadian Electrical Code.
HAWK ENTERPRISES 2902 Park Six Court, Elkhart, IN 46514 (574) 294-1910 www.hawkenterprises.com
HAWK ENTERPRISES 2902 Park Six Court, Elkhart, IN 46514 (574) 294-1910 www.hawkenterprises.com
HAWK AS 500 HEPA Air ScrubberHAWK AS 500 HEPA Air Scrubber250-500 Variable CFM250-500 Variable CFM