PRIMERGY

PRIMERGY RX100 S3Server System Operating ManualXenia FierleyFujitsu Siemens Computers GmbH cognitas PS81730 Münchene-mail: e-mail:[email protected].: (089) 61001-157Fax: (++49) 700 / 372 00000U41615-J-Z156-1-76Sprachen: En

Edition August 2005

Page 2: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Fax forms for sending us your comments are included inthe back of the manual.

There you will also find the addresses of the relevantUser Documentation Department.

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2000.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and TrademarksCopyright © 2005 Fujitsu Siemens Computers GmbH.

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

Page 3: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76

Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.1 Overview of the Documentation . . . . . . . . . . . . . . . . . . 51.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.3 Notational Conventions . . . . . . . . . . . . . . . . . . . . . . 91.4 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . 10

2 Installation Steps: Overview . . . . . . . . . . . . . . . . . 13

3 Important Notes . . . . . . . . . . . . . . . . . . . . . . . . 153.1 Notes on Safety . . . . . . . . . . . . . . . . . . . . . . . . . 153.2 CE Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . 203.3 FCC Class A Compliance Statement . . . . . . . . . . . . . . 203.4 Transporting the Server . . . . . . . . . . . . . . . . . . . . . 213.5 Notes on Installing the Rack . . . . . . . . . . . . . . . . . . 223.6 Environmental Protection . . . . . . . . . . . . . . . . . . . . 22

4 Hardware Installation . . . . . . . . . . . . . . . . . . . . . 254.1 Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . 254.2 Unpacking the Server . . . . . . . . . . . . . . . . . . . . . . 264.3 Installing/Removing the Server into/from the Rack . . . . . . . 274.3.1 Requirements of the Rack . . . . . . . . . . . . . . . . . . . . 284.3.2 Necessary Parts . . . . . . . . . . . . . . . . . . . . . . . . . 314.3.3 Preparing the Server . . . . . . . . . . . . . . . . . . . . . . 314.3.4 Mounting in the PRIMECENTER/DataCenter Rack . . . . . . . 324.3.5 Mounting in 3rd-Party Racks . . . . . . . . . . . . . . . . . . 344.3.6 Installing the Server . . . . . . . . . . . . . . . . . . . . . . . 354.4 Connecting Devices to the Server . . . . . . . . . . . . . . . . 364.4.1 Connecting the Monitor . . . . . . . . . . . . . . . . . . . . . 374.5 Connecting the Server to the Mains . . . . . . . . . . . . . . . 374.6 Instructions on Connecting and Disconnecting Cables . . . . . 38

5 Preparation for Use/Operation . . . . . . . . . . . . . . . . 395.1 Operating and Indicator Elements . . . . . . . . . . . . . . . . 395.1.1 The Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395.1.2 The Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425.2 Switching the Server ON/OFF . . . . . . . . . . . . . . . . . . 445.3 Configuring the Server . . . . . . . . . . . . . . . . . . . . . 465.3.1 Hard Disk Write Cache . . . . . . . . . . . . . . . . . . . . . 465.3.2 Configuration with ServerStart . . . . . . . . . . . . . . . . . 475.3.3 Configuration without ServerStart . . . . . . . . . . . . . . . . 485.4 Cleaning the Server . . . . . . . . . . . . . . . . . . . . . . . 49

Page 4: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76

Contents

6 Problem Solutions and Tips . . . . . . . . . . . . . . . . . . 516.1 Power-ON Indicator Remains Dark . . . . . . . . . . . . . . . 516.2 The Server Switches Itself OFF . . . . . . . . . . . . . . . . . 526.3 The Monitor Remains Dark . . . . . . . . . . . . . . . . . . . 526.4 Flickering Stripes Across the Monitor . . . . . . . . . . . . . . 536.5 No Monitor Display or Display Drifts . . . . . . . . . . . . . . . 536.6 No Mouse Pointer Displayed on the Monitor . . . . . . . . . . 536.7 Time and/or Date are Incorrect . . . . . . . . . . . . . . . . . 546.8 System Fails to Boot . . . . . . . . . . . . . . . . . . . . . . 546.9 Error Messages on the Monitor . . . . . . . . . . . . . . . . . 54

7 Property and Data Protection . . . . . . . . . . . . . . . . . 557.1 BIOS Setup security functions . . . . . . . . . . . . . . . . . 55

8 Hot-plug Hard Disk Drives . . . . . . . . . . . . . . . . . . . 578.1 Handling HDD Modules . . . . . . . . . . . . . . . . . . . . . 588.2 Installing/Removing a HDD/Dummy Module . . . . . . . . . . 59

Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

Page 5: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 5

1 IntroductionThe PRIMERGY RX100 S3 server is an Intel-based server for small and medium-sized networks and can be mounted into both, rack systems of the Fujitsu Siemens Computers GmbH and present rack systems from different manufacturers.

The PRIMERGY RX100 S3 server offers a high level of reliability and availability through highly developed hardware and software components. These include the ServerView server management software, Prefailure Detection and Analyzing (PDA) and Automatic Server Reconfiguration and Restart (ASR&R).

Security functions in the BIOS Setup and on the system board protect the data on the server against manipulation. Additional security is provided by the lockable rack door.

The server occupies 1 height unit (HU) in the rack.

1.1 Overview of the Documentation

I PRIMERGY manuals are available in PDF format on the ServerBooks CD. The ServerBooks CD is part of the ServerView Suite delivered with each server system.

The PDF files for the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found via the URL:http://manuals.fujitsu-siemens.com. For the documentation of the PRIMERGY servers choose the navigation point industry standard servers.

Concept and Target Group of this Manual

This operating manual describes how to install and how to operate your server.

This operating manual is intended for those responsible for installing the hardware and operating the system. The manual contains all the information required for mounting and operating your PRIMERGY RX100 S3.

To understand the different expansion options, you need a knowledge of hardware and data transmission, as well as basic knowledge of the operating system used.

Page 6: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

6 U41615-J-Z156-1-76

Overview of the Documentation Introduction

Additional components of the server documentation

To the PRIMERGY RX100 S3 documentation set belong the following additional manuals:

– “Quick Start Hardware - PRIMERGY RX100 S3” (poster)– “Quick Start Software - PRIMERGY ServerView Suite” (poster)– “Warranty” manual (print version delivered together with the system, PDF file

available on the ServerBooks CD)– “Safety” manual (print version delivered together with the system, PDF file

available on the ServerBooks CD)– “Ergonomics” manual (PDF file available on the ServerBooks CD)– “Returning used devices” (PDF file available on the ServerBooks CD)– “Helpdesk” (poster with worldwide helpdesk telephone numbers)– “PRIMERGY RX100 S3 Serversystem Options Guide” (PDF file available on

the ServerBooks CD)– Technical Manual for the system board D2004 (PDF file available on the

ServerBooks CD)– “BIOS Setup” manual (PDF file available on the ServerBooks CD)– “ServerView Suite” includes the ServerStart CD, the ServerBooks CD and the

print version of the manual “PRIMERGY ServerView Suite - ServerStart”. The PDF file of the manual is also available on the ServerBooks CD.

I If you need a backup of the ServerBooks CD, send the details of your server via email address: [email protected].

– “Global Array Manager Client Software User’s Guide” (PDF file available on the ServerBooks CD)

– “Global Array Manager Server Software User’s Guide” (PDF file available on the ServerBooks CD)

– “LSI SATA Software RAID User’s Guide” (PDF file available on the ServerBooks CD)

Further sources of information

– Technical Manual for the rack– manual for the monitor– server management manual ServerView– manual for the Remote Test and Diagnostic System RemoteView– operating system documentation– information files of your operating system

(see also “Related publications” on page 63).

Page 7: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 7

Introduction Features

1.2 Features

System Board

The features of the system board can be found in the Technical Manual of the system board D2004 for the hardware and in the “BIOS Setup” for the firmware (see “Related publications” on page 63).

Hard Disk Drives

The server may have a maximum of two hard disk drives with SATA interface. There are two server variants:

– Server with non hot-plug hard disk drives (mounted in an “easyChange” hard disk carrier)

– Server with hot-plug hard disk drives (see “Hot-plug Hard Disk Drives” on page 57)

The different features of each server variant are described in the appropriate sections of this manual.

Accessible Drives

An CD or DVD drive is available.

Power Supply

The server has a fixed, wide range power supply unit that adjusts automatically to a power voltage in the range from 100 V - 127 V or 200 V - 240 V.

High Level of Availability and Reliability

When memory data are accessed, 1-bit errors in the main memory are recog-nized and automatically corrected with the ECC (Error Correcting Code) method.

ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in the case of an error and automatically ”hides“ the defective system components.

The PDA (Prefailure Detection and Analyzing) technology from Fujitsu Siemens Computers analyzes and monitors all components important for system reliability.

Page 8: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

8 U41615-J-Z156-1-76

Features Introduction

Server Management

Server management is implemented with the aid of the supplied ServerView software and PDA (Prefailure Detection and Analyzing) technology from Fujitsu Siemens Computers. PDA reports early the threat of a system error or overloading so that preventative measures can be taken.

ServerView enables the management of all PRIMERGY servers in the network via a central console. Here ServerView supports the following functions:

● Remote startup (Wakeup On LAN)

● Temperature monitoring of the CPU and the surrounding area

● Power monitoring

● End-of-life monitoring of the fans with timely notification before a failure

● Watchdog timer for operating system monitoring and application monitoring with ASR&R

Further information on the ServerView server management is provided in the associated documentation (see “Related publications” on page 63).

Server Management LAN (SM LAN)

The Server Management LAN is a direct communication interface between a remote system and the local BMC. It is used for “Console Redirection” (text and grafical) and for transferring e. g. power management commands from the remote system to the BMC via LAN.

The LAN connection (only LAN port 1) (see section “Connecting Devices to the Server” on page 36) can be exclusive for management or be shared with the standard OS.

ServerStart

You can configure the PRIMERGY server quickly and precisely with the ServerStart software provided. User-guided menus are available for installing the server operating systems.

Page 9: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 9

Introduction Notational Conventions

Service and Support

PRIMERGY server are service-friendly and modular, thus enabling quick and simple maintenance. The flash EPROM program supplied with the Fujitsu Siemens Computers utilities supports fast BIOS Update.

The optional RemoteView Remote Test and Diagnosis System allows the PRIMERGY RX100 S3 Server to be maintained from remote locations. A Remote Service Board (RSB) can be used in conjunction with RemoteView. Together they facilitate a remote diagnosis for system analysis, remote configu-ration, and remote restart should the operating system or hardware fail.

1.3 Notational Conventions

The following notational conventions are used in this manual:

Italics indicate commands, menu items or software programs.

“Quotation marks” indicate names of chapters and terms that should be emphasized.

Ê text which follows this symbol describes activities that must be performed in the order shown.

V CAUTION! pay particular attention to text marked with this symbol. Failure to observe this warning may endanger your life, damage the server, or lead to loss of data.

I supplementary information, remarks, and tips follow this symbol.

Table 1: Notational Conventions

Page 10: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

10 U41615-J-Z156-1-76

Technical Data Introduction

1.4 Technical Data

Electrical Data

Compliance Standards

Rated voltage range 100 V - 127 V or 200 V - 240 V

Rated frequency 50 Hz - 60 Hz

Rated current in basic configuration: 100 V - 127 V / 1.86 A200 V - 240 V / 0.98 A

Max. rated current: 100 V - 127 V / 4 A200 V - 240 V / 2 A

Active power 254 W

Apparent power 254 VA

Thermal dissipation 914.4 kJ/h (866.68 btu/h)

Main power fuse 16 A (6.3 A)

Protection class I

Product safety and ergonomics IEC 60950 / EN 60950, UL 1950 3rd. Ed., CAN/CSA 22.2 No. 60950 3rd. Ed.

Electromagnetic Compatibility(standard power supply)

FCC class AVCCI class A /JEIDACNS 13438 class AC-Tick class A

Emitted interference EN 55022 class A

Harmonic current EN 61000-3-2

Flicker EN 61000-3-3

Noise immunity EN 55024

CE label according to EU directives

Low-Voltage Directive 73/23/EEC Electromagnetic Compatibility 89/336/EEC

Page 11: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 11

Introduction Technical Data

Mechanical Values

Weight

Approx. 12 kg (depending on the configuration)

Ventilation Clearance

At least 200 mm on the front and on the rear side

Environmental Conditions

Condensation during operation must be avoided.

Noise Level

Width 430 mm

Depth device 560 mm

Height 42.5 mm or 1 HU

Environment class 3K2Environment class 2K2

EN 60721 / IEC 721 section 3-3 EN 60721 / IEC 721 section 3-2

Temperature: Operation (3K2) Transport (2K2)

10 °C ... 35 °C-25 °C ... 60 °C

Relative humidity 10% ... 85%

Sound power level LWAd (ISO 9296) < 6.4 B (standby)< 6.7 B (operating)

Sound pressure level at bystander position LpAm (ISO 9296)

< 51.7 dB (A) (standby) < 56.3 dB (A) (operating)

Page 12: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens
Page 13: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 13

2 Installation Steps: OverviewIn this chapter you will find an overview of the steps necessary to install your server system. Links guide you to sections where you can find more detailed information on the individual steps:

Ê At first, please take notice of chapter “Important Notes” on page 15ff, especially of „Notes on Safety“.

Ê Unpack the system, check the contents of the package for visible transport damage and check whether the delivery agrees with the details in the delivery note (see section “Unpacking the Server” on page 26).

Ê Transport the server to the place where you want to set it up.

Ê Make sure all necessary manuals (see section “Overview of the Documen-tation” on page 5) are available; possibly print of the PDF files.

Ê Mount the server into the rack (see section “Installing/Removing the Server into/from the Rack” on page 27).

Ê Cable the server. Please also refer to the section “Connecting Devices to the Server” on page 36 and section “Instructions on Connecting and Discon-necting Cables” on page 38.

Ê Connect the system to the line voltage (see section “Connecting the Server to the Mains” on page 37).

Ê Make yourself familiar with the operating and indicator elements on the front and on the rear side of the server (see section “Operating and Indicator Elements” on page 39).

Ê Configure the server and install the desired operating system and the appli-cations. To do so, you have the following possibilities:

– Remote configuration and installation with ServerStart:

With the ServerStart-CD provided, you can configure the server and install the operating system in a convenient manner.

Configuring the SATA RAID controller with GAM (Global Array Manager).

To find out how to operate ServerStart and for further information, refer to the corresponding manual “PRIMERGY ServerView Suite - ServerStart”.

Additional configuring information is contained in section “Configuration with ServerStart” on page 47).

Page 14: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

14 U41615-J-Z156-1-76

Installation Steps: Overview

– Local configuration and installation with or without ServerStart (see section “Configuration with ServerStart” on page 47 and/or section “Configuration without ServerStart” on page 48).

Configuring the SATA RAID controller during BIOS-POST with CTRL-M or with GAM (Global Array Manager) after the installation of the Operating System.

Page 15: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 15

3 Important NotesIn this chapter you will find essential information regarding safety when working with your server.

3.1 Notes on Safety

I You will also find the following safety instructions in the manual entitled “Safety“.

This device complies with the relevant safety regulations for data processing equipment.

If you have any questions, contact your sales outlet or our customer service centre.

V CAUTION!

The actions described in these instructions should only be performed by technical specialists. Equipment repairs should only be performed by authorized, qualified staff. Any unauthorized openings and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability.

Page 16: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

16 U41615-J-Z156-1-76

Notes on Safety Important Notes

Before Setting up

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for you device (see section “Technical Data” on page 10).

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine.

Before operating the device, wait until it is absolutely dry and has reached approximately the same temperature as the installation site. Failure to observe these guidelines can lead to material damage of the device.

● Transport the device only in the original packaging or in a packaging which protects it from knocks and jolts.

Installation and Operation

V CAUTION!

● If the server is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector.

● The server automatically adjusts to a mains voltage between 100 V - 127 V or 200 V - 240 V. The server may be place in operation only, if the mains voltage range set on the server corresponds to the local mains voltage.

● This device has a specially approved power cable and must only be connected to a grounded insulated socket.

● The ON/OFF button does not disconnect the device from the mains voltage. To completely disconnect it from the mains voltage, remove the power plug from the insulated socket.

● Always connect the device and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the central processing unit is still running but the peripheral device (e.g. storage subsystem) has failed during a power outage.

Page 17: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 17

Important Notes Notes on Safety

V CAUTION!

● Data cables must be adequately shielded to avoid interference.

● To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174-1/2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 Mbps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC 11801 are to be considered.

● Route the cables in such a way that they do not form a potential hazard and that they cannot be damaged. Refer to the relevant notes in the operating manual when connecting the device.

● No data transmission cable should be connected or disconnected during a thunderstorm (lightning hazard).

● In emergencies (e.g. damaged casing, elements, or cables, penetration of liquids or foreign matter), switch off the device immedi-ately, remove the power connector from the grounded power socket, and contact your customer service centre.

● Proper operation of the device (in accordance with IEC 60950/ EN 60950) is only ensured if the casing is completely assembled and the rear covers for the installation openings have been put in place (electric shock, cooling, fire protection, interference suppression).

● Install only system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment. If you install other expan-sions, you may damage the system or violate the safety regulations and regulations governing RFI suppression. Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet.

● The components marked with a warning label (e.g. lightning symbol) may only be opened, removed, or exchanged by authorized, qualified personnel.

● The warranty is invalidated if the device is damaged during the instal-lation or replacement of system expansions.

● You may set only those resolutions and refresh rates specified in the ”Technical data“ section of the monitor description. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service centre.

Page 18: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

18 U41615-J-Z156-1-76

Notes on Safety Important Notes

Batteries

V CAUTION!

● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the Technical Manual for the system board under “Related publications” on page 63).

● Replace the lithium battery on the system board in accordance with the instructions in the Technical Manual for the system board (see “Related publications” on page 63).

Note about the Laser

The CD/DVD drive is classified for laser class 1 according to IEC 60825-1.

V CAUTION!

The CD/DVD drive contains a laser diode (LED). Sometimes, the LED produces a stronger laser beam than laser class 1. Direct view into the laser beam is dangerous.

Never remove parts of the CD/DVD drive assembly!

Notes on Handling CDs/DVDs and CD/DVD Drives

V CAUTION!

● Use only CDs/DVDs in proper condition in the CD/DVD drive of your server to prevent data loss, damage to the device and injuries.

● Therefore, check each CD/DVD for damage, cracks, breakage etc. before inserting it in the drive.

Please note that any additional labels applied may change the mechanical properties of a CD/DVD and cause imbalance.

Damaged and imbalanced CDs/DVDs can break at high drive speeds (data loss).

Under certain conditions, sharp-edged pieces of broken CDs/DVDs can penetrate the cover of the drive (damage to the device) and be thrown out of the device (danger of injury, particularly on uncovered body parts such as the face or neck).

Page 19: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 19

Important Notes Notes on Safety

I You protect the CD/DVD drive and prevent mechanical damage, as well as premature wearing of the CDs/DVDs by observing the following suggestions:

– Only insert the CDs/DVDs in the drive when needed and remove them after use.

– Store the CDs/DVDs in suitable sleeves.– Protect the CDs/DVDs from exposure to heat and direct sunlight.

Modules with Electrostatic Sensitive Devices:

Electrostatic-sensitive components may be identified by the following sticker:

Figure 1: ESD label

When you handle components fitted with ESDs, you must observe the following points under all circumstances:

● You must always discharge static build up (e.g. by touching a grounded object) before working.

● Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components.

● The equipment and tools you use must be free of static charge.

● Remove the power plug from the power socket before inserting or removing components containing ESDs.

● Always hold components with ESDs at the edges or at the positions highlighted in green (touch points).

● Do not touch any exposed pins or conductors on a component.

● Place all components on a static-safe base.

I You will find a detailed description for handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).

Page 20: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

20 U41615-J-Z156-1-76

CE Certificate Important Notes

Other Important Notes:

● When cleaning the device, please observe the relevant notes in the section “Cleaning the Server” on page 49.

● Keep this Operating Manual safety and all additional documentation (e.g. Technical Manual, CD) together with the device. If you pass on the device to third parties, you should also pass on the complete documentation.

3.2 CE Certificate

3.3 FCC Class A Compliance Statement

If there is an FCC statement on the device, then:

The following statement applies to the products covered in this manual, unless otherwise specified herein. The statement for other products will appear in the accompanying documentation.

NOTE:

This equipment has been tested and found to comply with the limits for a „Class A“ digital device, pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference-Causing Equipment Standard ICES-003 for digital apparatus. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in strict accordance with the instructions, may cause harmful interference to radio communications. However, there is no warranty that inter-ference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

The shipped version of this device complies with the requirements of the EEC directives 89/336/EEC ”Electromagnetic compatibility“ and 73/23/EEC ”Low voltage directive“. The device therefore qualifies for the CE certificate (CE=Communauté Européenne).

Page 21: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 21

Important Notes Transporting the Server

● Reorient or relocate the receiving antenna.

● Increase the separation between equipment and the receiver.

● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

● Consult the dealer or an experienced radio/TV technician for help.

Fujitsu Siemens Computers is not responsible for any radio or television inter-ference caused by unauthorized modifications of this equipment or the substi-tution or attachment of connecting cables and equipment other than those specified by Fujitsu Siemens Computers. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.

The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules.

3.4 Transporting the Server

V CAUTION!

Transport the server only in its original packaging or in a packaging which protects it from knocks and jolts. Do not unpack the server until you are done transporting.

If you need to lift or transport the server, ask other people to help you.

Page 22: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

22 U41615-J-Z156-1-76

Notes on Installing the Rack Important Notes

3.5 Notes on Installing the Rack

● When connecting and disconnecting cables, observe the relevant notes in the chapter ”Important notes“ in the Technical Manual for the corresponding rack. The Technical Manual is supplied with the corresponding rack.

● Ensure that the anti-tilt bracket is correctly mounted when you set up the rack.

● For safety reasons, only one unit should be withdrawn from the rack at any one time.

● If several units are withdrawn at the same time from the rack there is a danger that the rack will tilt forward.

● The power connection for the rack must be installed by an authorized technician (electrician).

● If the rack model is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector.

3.6 Environmental Protection

Environmentally friendly product design and development

This product has been designed in accordance with standards for ”environmen-tally friendly product design and development“. This means that the designers have taken into account important criteria such as durability, selection of materials and coding, emissions, packaging, the ease with which the product can be dismantled and the extent to which it can be recycled.

This saves resources and thus reduces the harm done to the environment.

Notes on saving energy

Devices that do not have to be on permanently should not be switched on until they need to be used and should be switched off during long breaks and on completion of work.

Page 23: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 23

Important Notes Environmental Protection

Notes on packaging

Please do not throw away the packaging. We recommend that you do not throw away the original packaging in case you need it later for transporting your system unit. If possible, devices should be transported in their original packaging.

Notes on dealing with consumables

Please dispose of printer consumables and batteries in accordance with local government regulations.

Do not throw batteries and accumulators into the household waste. They must be disposed of in accordance with local regulations concerning special waste.

All batteries containing pollutants are marked with a symbol (a crossed-out rubbish bin on wheels). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant:

Cd Cadmium Hg Mercury Pb Lead

Notes on labeling plastic housing parts

Please avoid attaching your own labels to plastic housing parts wherever possible, since this makes it difficult to recycle them.

Page 24: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

24 U41615-J-Z156-1-76

Environmental Protection Important Notes

Returning, recycling and disposal

For details on returning and reuse of devices and consumables within Europe, refer to the “Returning used devices” manual, or contact your Fujitsu Siemens Computers branch office/subsidiary or our recycling centre in Paderborn:

Fujitsu Siemens ComputersRecycling CenterD-33106 Paderborn

Tel. +49 5251 8 18010

Fax +49 5251 8 18015

The device may not be disposed of with household rubbish. This appliance is labelled in accordance with European Directive 2002/96/EC concerning used electrical and electronic appliances (waste electrical and electronic equipment - WEEE).The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU. To return your used device, please use the return and collection systems available to you. You will find further information on this at www.fujitsu-siemens.com/recycling.

Page 25: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 25

4 Hardware InstallationV CAUTION!

Please note the safety instructions in chapter “Important Notes” on page 15.

Do not expose the server to extreme environmental conditions (see section “Technical Data” on page 10). Protect it from dust, moisture, and heat.

The server must be acclimatized in its operating environment for an accli-matization time.

4.1 Installation Steps

The following installation steps are described in detail in other sections of this chapter:

Ê Unpacking the server (see next section “Unpacking the Server”).

Ê Mounting the server into the rack (see the layout arrangement created with System Architect on the order lists).

Ê Cabling the server. Please also refer to the section “Instructions on Connecting and Disconnecting Cables” on page 38.

Ê Connecting the server to the power supply (see section “Connecting the Server to the Mains” on page 37).

Temperature difference (°C)(operating environment/outside)

Minimum acclimatization time (hours)

5 3

10 5

15 7

20 8

25 9

30 10

Table 2: Acclimatization time

Page 26: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

26 U41615-J-Z156-1-76

Unpacking the Server Hardware Installation

4.2 Unpacking the Server

V CAUTION!

Please note the safety instructions in chapter “Important Notes” on page 15.

Do not unpack the server until you are done transporting.

It is recommended to not throw away the original packaging material! It may be required for transportation at some later date.

Ê Unpack all the individual parts.

Ê Check the contents of the package for visible transport damage.

Ê Check whether the delivery agrees with the details in the delivery note.

The identification rating plate is located on the rear area on the server.

If you find transport damage or inconsistencies between the contents of the package and the delivery note, inform your supplier immediately!

Ê Transport the server to the place where you want to set it up.

Page 27: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 27

Hardware Installation Installing/Removing the Server into/from the Rack

4.3 Installing/Removing the Server into/from the Rack

V CAUTION!

● Please note the safety instructions in chapter “Important Notes” on page 15 and in section “Notes on Installing the Rack” on page 22.

● The rack can tip over when more than one slide-in unit is pulled out.

V CAUTION!

There is no cable management for the server in the rack!

Before the server is removed, all cables must be disconnected from the sockets. Please proceed as follows:

– Terminate all applications and shut down the operating system.

– Switch off the server.

– Disconnect and remove all cables connected to the server.

– Remove the server from the rack.

Page 28: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

28 U41615-J-Z156-1-76

Installing/Removing the Server into/from the Rack Hardware Installation

4.3.1 Requirements of the Rack

The rack systems of the Fujitsu Siemens Computers (PRIMECENTER Rack, DataCenter Rack) support fully the installation of the PRIMERGY RX100 S3 server system. The installation into the at present usual rack systems of different foreign manufacturers (3rd-Party Rack) is supported to large part.

To accommodate the ventilation concept and ensure proper ventilation of the components in the rack, any unused areas must be closed using dummy covers.

The power is supplied via the socket strips available in the rack.

The main features of the rack systems of the Fujitsu Siemens Computers are:

PRIMECENTER Rack

– Frontally bolted telescopic rails (in the rear left area a support bracket is used).

The rails are provided with a linear alignment possibility to ensure also an adjustment to different rack depths.

DataCenter Rack

– Frontally or laterally bolted telescopic rails (in the rear left area a support bracket is used).

The rails are provided with a linear alignment possibility to ensure also an adjustment to different rack depths.

Page 29: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 29

Hardware Installation Installing/Removing the Server into/from the Rack

3rd-Party Rack

Certain boundary conditions are to be fulfilled:

– Installation dimensions (see the dimensions shown in figure 2 on page 30):

– The operability of the safety mechanisms at the server e.g. stoppers or holding back systems must be guaranteed.

– The form of the rack support uprights must ensure the frontal screwing on of the rails.

– Frontally bolted telescopic rails.

The rails are provided with a linear alignment possibility to ensure also an adjustment to different rack depths.

– Climatic conditions.For the ventilation of the installed server a large extent unhindered air intake in the rack front and air discharge in the rear cover of the rack are necessary.

In principle the ventilation concept plans that the necessary cooling is reached by the horizontal self-ventilation of the installed devices (air flow from the front to the rear).

1 rack front side

2 rack rear side

A rack depth (comparison PRIMECENTER Rack 940/1000 mm)

B rack width (comparison PRIMECENTER Rack 700 mm)

C clearance of the 19-inch installation level

C1 front 19-inch installation level

C2 rear 19-inch installation level

D area for cable routing (cable area depth) and ventilation

E area for front panel and ventilation

F right and left area for support systems

P PRIMERGY installation depth

a1 front left support upright

a2 front right support upright

b1 rear left support upright

b2 rear right support upright

Page 30: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

30 U41615-J-Z156-1-76

Installing/Removing the Server into/from the Rack Hardware Installation

– Power supply.For the installation in 3rd-Party Racks it is to be made certain that appro-priate socket strips are present.

Figure 2: Mechanical conditions

Page 31: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 31

Hardware Installation Installing/Removing the Server into/from the Rack

4.3.2 Necessary Parts

For mounting the server into the appropriate rack the following parts are available:

– support bracket – one left and one right telescopic rail (assembled)

4.3.3 Preparing the Server

Ê Open one of the telescopic rails completely.

Ê Push the locking spring and pull the u-shaped telescopic bar completely out from the rail.

Ê Repeat both steps with the second telescopic rail.

Figure 3: Fastening the telescopic bar to the server

Ê Place the u-shaped telescopic bars with the flat side on the left and/or on the right on the server.

Ê Fasten the telescopic bars with 3 screws (M4) each, to the server (left and right).

Page 32: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

32 U41615-J-Z156-1-76

Installing/Removing the Server into/from the Rack Hardware Installation

4.3.4 Mounting in the PRIMECENTER/DataCenter Rack

I General information is provided in the Technical Manual for the PRIME-CENTER and/or DataCenter Rack (see “Related publications” on page 63).

Mounting the support bracket

When mounting the left telescopic rail in the PRIMECENTER/DataCenter Rack, the supplied support bracket must first be mounted level with the device on the rear left support upright.

I For better orientation the height units are marked on the support uprights (PRIMECENTER Rack only).

Ê Place the support bracket at the appropriate height on the left rear support upright by inserting the positioning nub (1 in figure 4) in the corresponding hole of the support upright.

Figure 4: Mounting the support bracket

Ê Secure the bracket with two screws incl. plugwashers.

Page 33: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 33

Hardware Installation Installing/Removing the Server into/from the Rack

Mounting the rails

To fasten the telescopic rails, no flange nuts are necessary since the rails are equipped with threaded holes.

Figure 5: Mounting the left telescopic rail

Ê Position the left telescopic rail onto the support bracket by inserting the small horizontal lead (between the securing holes on the rear end of the rail) in the corresponding hole.

Ê Press the rail together, and position it onto the frontal support upright, and release it again. The rail will be adjust automatically in the rack clearance depth.

Ê Secure the telescopic rail on the frontal left support upright and on the support bracket, each with two screws M5x10 incl. plugwashers.

Ê Repeat the steps with the right telescopic rail (to be mounted on the right support uprights).

Ê Mount the server (see section “Installing the Server” on page 35).

Page 34: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

34 U41615-J-Z156-1-76

Installing/Removing the Server into/from the Rack Hardware Installation

4.3.5 Mounting in 3rd-Party Racks

For mounting the server in the 3rd-Party Rack the following parts are necessary:

– one left and one right telescopic rail (assembled)

Ê Take the original manual of the rack manufacturer regarding the mechanical installation and/or the climatic conditions to assistance.

V CAUTION!

With the installation in 3rd-Party Rack it is to be made certain that the air flow is ensured from the front to the rear in the rack.

Ê Mount the necessary manufacturer original parts (like support brackets).

I Sometimes a number of parts of the delivered mounting kit cannot be used because original parts of the 3rd-Party Rack are to be used.

Ê Mount the telescopic bars as described in section “Preparing the Server” on page 31.

Ê Secure the telescopic rails into the rack as described in section “Mounting in the PRIMECENTER/DataCenter Rack” on page 32.

Ê Mount the server (see section “Installing the Server” on page 35) and route the cables as described in the original manual of the rack.

Page 35: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 35

Hardware Installation Installing/Removing the Server into/from the Rack

4.3.6 Installing the Server

Ê Position the prepared server (see section “Preparing the Server” on page 31) into the telescopic rails, push the locking springs (1) and insert the server until the telescopic bars click into place (2).

Figure 6: Fitting the Server in the Rack

Ê Push the server completely into the rack (3).

I After you have inserted the server, you should pull out the server again completely and insert it again into the rack. Thus it is guaranteed that the server runs cleanly in the telescopic rails.

Ê Fasten the server (front panel) using two knurled screws (4).

The server is removed in the reverse order.

V CAUTION!

There is no cable management for the server in the rack!

Before the server is removed, all cables must be disconnected from their sockets. Before you remove the server, please observe the hints in section “Installing/Removing the Server into/from the Rack” on page 27.

1

2

3

4

24

Page 36: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

36 U41615-J-Z156-1-76

Connecting Devices to the Server Hardware Installation

4.4 Connecting Devices to the Server

The ports for external devices are on the front and on the rear of the server. Which additional ports are available on your server depends on the PCI boards installed.

The standard ports (figure 7) on the rear are marked with symbols, and some are color-coded:

Figure 7: Ports on the rear

There is an additional USB port on the right front side of the server.

I The COM1 port (1) is disabled by default. This setting may be changed in the BIOS Setup.

I Some of the devices that you connect require special driver software (see the documentation for the connected device).

Ê Connect the data cables to the server and peripherals.

1 Serial port (COM1, disabled by default)

4 Monitor port (VGA) (blue)

2 Mouse port (PS/2) (green) 5 LAN port 1 incl. Server Management LAN (SM LAN) (see “Server Management LAN (SM LAN)” on page 8)

3 Keyboard port (PS/2) (purple) 6 LAN port 2

7 USB ports 1 and 2

Page 37: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 37

Hardware Installation Connecting the Server to the Mains

4.4.1 Connecting the Monitor

Ê Plug the data cable of the monitor into the monitor port (4).

Ê Connect the insulated connector of the monitor power cable to a grounded mains socket in the socket strip of the rack (see also the Technical Manual of the rack).

4.5 Connecting the Server to the Mains

The server has a fixed power supply unit.

V CAUTION!

The server automatically adjusts to a mains voltage between 100 V - 127 V or 200 V - 240 V. The server may be operated only, if the mains voltage range set on the server corresponds to the local mains voltage.

Ê Connect the insulated connector of the power cable to the power supply unit of the server.

Ê Connect the power plug to a insulated socket in the socket strip of the rack (see also the Technical Manual of the rack).

Page 38: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

38 U41615-J-Z156-1-76

Connecting and Disconnecting Cables Hardware Installation

4.6 Instructions on Connecting and Disconnecting Cables

V CAUTION!

Be sure to read the documentation for the peripheral devices before connecting them.

Do not connect or disconnect data cables during a thunderstorm.

When removing a cable, always hold it by the plug.

Connect and disconnect the cables in the order described below.

Connecting cables

Ê Turn off all power and equipment switches.

Ê Pull all power plugs out of grounded power sockets.

Ê Plug all cables into the server and peripherals. Secure the data transmission cable connections (e. g. nut retention).

Ê Plug all data communication cables into the utility sockets.

Ê Plug all power cables into the grounded power sockets.

Disconnecting cables

Ê Turn off all power and equipment switches.

Ê Pull all power plugs out of grounded power sockets.

Ê Unplug all data communication cables from the utility sockets.

Ê Loosen the nut retentions on the connector housings and pull the corre-sponding cables out from the server and from the peripherals.

Page 39: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 39

5 Preparation for Use/OperationV CAUTION!

Please note the safety instructions in chapter “Important Notes” on page 15.

5.1 Operating and Indicator Elements

5.1.1 The Front

Figure 8: Operating and indicator elements on the front (hot-plug system)

1 CD-ROM access indicator (green)

Lights up green when the storage medium is being accessed.

2,3 HDD indicators (hot-plug hard disk drives only)

For explanation see table 4 on page 42.

4 HDD access indicator (green)

Flashes green when a hard disk drive is being accessed.

Table 3: Indicators and operating elements on the front

NMI

ID RST ID

Page 40: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

40 U41615-J-Z156-1-76

Operating and Indicator Elements Preparation for Use/Operation

5 Identification indicator (blue)

Lights up blue when the system has been selected by pressing the identification button (7). To deactivate, press the button again. The identification indicator lights up synchronously with the corresponding indicator on the rear.

The indicator can also be selected via ServerView and its status is also reported to ServerView.

6

RST

Reset button

Pressing the reset button with a pointed object (e.g. a bent paperclip) reboots the system.

7

ID

Identification button

Pressing this button lights up synchronously the identification indicators on the front and on the rear of the server.

8 ON/OFF button

When the system is switched OFF, it can be switched ON by pressing the ON/OFF button. When the system is operating, pressing the ON/OFF button will switch OFF the system. More hints may be found in section “Other ON/OFF possibilities” on page 45.

I The ON/OFF button does not disconnect the server from the mains voltage. To completely disconnect it from the mains voltage, remove the power plug from the socket.

9

NMI

NMI button

Pressing the NMI button with a pointed object (e.g. a bent paperclip) shuts the operating system down immediately.

I Please, do not use it! The NMI button may only be used by service personnel.

10 Power-on indicator (bicolor)

Lights up green when the server is switched ON.

Flashes green when the system is in standby mode.

Lights up amber when the server is in shutdown mode (shut down of the operating system) and/or is switched OFF.

Table 3: Indicators and operating elements on the front

Page 41: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 41

Preparation for Use/Operation Operating and Indicator Elements

Hard disk drive control indicators

Figure 9: Hot-plug HDD module: indicators

11 Global Error indicator (amber)

Does not light when the system is ok. No service incident or critical event has occurred.

Flashes amber when a critical event has occurred. Users can check BIOS Setup, systemlog and eventlog or via ServerView for event details. The indicator also flashes in standby mode.

Lights amber when a prefailure event has been recognized. Users can check systemlog and eventlog or via ServerView for event details. The indicator also lights in standby mode.

If the event is still acute after a power failure, the indicator is activated after the restart.

12 Floppy disk drive access indicator (green)

Lights up green when the storage medium is being accessed.

Table 3: Indicators and operating elements on the front

!

Page 42: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

42 U41615-J-Z156-1-76

Operating and Indicator Elements Preparation for Use/Operation

5.1.2 The Rear

Figure 10: Indicators on the rear

LED green

HDD BUSY

– lights: HDD in active phase– does not light: HDD inactive

LED amber

HDD FAULT

– does not light: No HDD Error– lights: HDD Faulty or Rebuild Stopped (drive defective/needs

replacing, a rebuild process was stopped or the HDD module is not correctly inserted)

– slow flash: HDD Rebuild (the data is restored by the RAID controller after changing a hard disk drive)

Table 4: Meaning of hot-plug HDD module LED indicators

Page 43: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 43

Preparation for Use/Operation Operating and Indicator Elements

1 Global Error indicator (amber)

Does not light when the system is ok. No service incident or critical event has occurred.

Flashes amber when a critical event has occurred. Users can check BIOS Setup, systemlog and eventlog or via ServerView for event details. The indicator also flashes in standby mode.

Lights amber when a prefailure event has been recognized. Users can check systemlog and eventlog or via ServerView for event details. The indicator also lights in standby mode.

If the event is still acute after a power failure, the indicator is activated after the restart.

2,3 LAN port s indicators

Each LAN port (1 and 2) is equipped with a green LED indicator (3) on the left upper side and a amber/green LED indicator (4) on the right upper side.

These indicators are described in the Technical Manual for the D2004 system board (see “Related publications” on page 63).

4 Identification indicator (blue)

Pressing the identification button on the front panel lights up synchro-nously the integrated identification indicator on the front and on the rear of the server.

Lights up blue when the system has been selected by pressing the identification button. To deactivate, press the button again.

The indicator can also be activated via ServerView and its status is also reported to ServerView.

Table 5: Indicators on the rear

Page 44: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

44 U41615-J-Z156-1-76

Switching the Server ON/OFF Preparation for Use/Operation

5.2 Switching the Server ON/OFF

The ON and OFF indicators and operating elements may be found in figure 8 on page 39 with the associated table on page 39.

V CAUTION!

If after switching ON the server there is nothing but flickering stripes on the screen, switch the server OFF immediately (see chapter “Problem Solutions and Tips” on page 51).

The ON/OFF button does not disconnect the server from the mains voltage. To completely disconnect it, you must pull the power plug.

Switching the server ON

– First system installation:

Ê Press the ON/OFF button.

Ê Insert the ServerStart CD and/or an installation disk into the corre-sponding drive.

Ê Follow the instructions on the monitor (see also section “Configuring the Server” on page 46).

– System already installed:

Ê Press the ON/OFF button.

The server is switched ON, performs a system test and boots the operating system.

Switching the server OFF

Power-on indicator lights up green.

Ê Shut down the operating system in an orderly manner.

The power-on indicator lights up amber.

Ê Press the ON/OFF button and/or send a corresponding control signal (see “Other ON/OFF possibilities” on page 45).

The server switches OFF.

Page 45: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 45

Preparation for Use/Operation Switching the Server ON/OFF

Server in standby mode

Power-on indicator flashes green. The ON/OFF button is being pressed.

System fans speed slows down due to a IPMI signal.

Ê Shut down all RGB applications.

Ê Press any button to return to normal operation.

Other ON/OFF possibilities

In addition to the ON/OFF button, the server can be switched ON and OFF in the following ways:

– Specified switch-On time/switch-OFF time

The server is switched ON or OFF at a time specified in the ServerView program.

– Ring indicator

The server is switched ON via an internal or external modem.

– Wakeup On LAN (WOL)

The server is switched ON by a command via the LAN.

– After power failure

The server automatically switches ON following a power failure (depending of the settings in the BIOS).

– Power override function

The system may be switched OFF “unconditionally” by pressing the ON/OFF button for about 4 to 5 seconds.

V CAUTION!

Data loss may occur!

– IPMI

The server is switched ON by an IPMI console (via the serial COM1 port or via the LAN port 1). If necessary, the COM1 port must first be enabled in the BIOS Setup, as it is disabled by default.

Page 46: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

46 U41615-J-Z156-1-76

Configuring the Server Preparation for Use/Operation

5.3 Configuring the Server

This section contains information about configuring the server and installing the operating system.

I Make sure that the energy saving functions are disabled in the BIOS Setup during server operation.

5.3.1 Hard Disk Write Cache

By default, the hard disk write cache is disabled. This presetting may be changed. Consequently, not every data modification in main memory is written to disk immediately, thus boosting system performance during write operations.

V CAUTION!

When a power failure occurs with enabled write cache, data may be lost!

I The hard disk write cache can only be configured in the same way for all SATA disk drives at once.

Using SATA Software RAID

Ê While the server is booting (POST), press CTRL-M.

Ê Select Objects.

Ê Select Adapter.

Ê Select Adapter-0 <bus=00, dev=IF>.

Ê Select Write Cache = On.

Ê Press any key to confirm the warning message.

Ê Press ESC.

More information on configuring is contained in the LSI SATA Software RAID manual (see also “Related publications” on page 63).

Page 47: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 47

Preparation for Use/Operation Configuring the Server

Using Global Array Manager (GAM)

The Write Cache can only be enabled via the RAID Assist wizard of the Global Array Manager while the configuration of the SATA RAID controller is performed.

Ê Open the RAID Assist wizard and follow the instructions on the screen.

Ê Set Write Cache to enabled.

You find more information in the “Global Array Manager Client Software User’s Guide” (see also “Related publications” on page 63).

5.3.2 Configuration with ServerStart

With the ServerStart CD provided, you can configure the server and install the operating system in a convenient manner.

The menu-guided configuration includes the SATA RAID controller configuration with GAM (Global Array Manager, see “Related publications” on page 63).

I SATA-ID information:

Please note that the SATA IDs for the hot-plug hard disk drives are fixed (from right to left in the order 0, 1).

I Descriptions of operating systems not covered in the SATA RAID controller manual are provided in the appropriate readme files on the driver CDs.

To find out how to operate ServerStart and for further information, refer to the corresponding ServerStart manual (see “Related publications” on page 63).

If you use ServerStart, you can skip the following section on how to configure the server and install the operating system. Continue with section “Cleaning the Server” on page 49.

Page 48: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

48 U41615-J-Z156-1-76

Configuring the Server Preparation for Use/Operation

5.3.3 Configuration without ServerStart

Configuring the SATA RAID controller

RAID levels 0 (striping) and 1 (mirroring) are supported.

Configure the SATA RAID controller before OS loads (POST) with CTRL-M (see also the LSI SATA Software RAID manual on the ServerBooks CD) or after OS loads with GAM (Global Array Manager, see also “Related publications” on page 63).

Installing the operating system

Ê Insert the installation CDs of the operating system you want to install.

Ê Reboot the server.

Ê Follow the instructions on the screen and in the manual for the operating system.

Please read how to install the desired operating system in the related LSI SATA Software RAID manual.

I Please also read the BIOS Setup manual (see also “Related publications” on page 63).

Page 49: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 49

Preparation for Use/Operation Cleaning the Server

5.4 Cleaning the Server

V CAUTION!

Switch the server off, and pull the power plug out of the grounded-contact power socket.

Do not clean any interior parts yourself; leave this job to a service technician.

Do not use any cleaning agents that contain abrasives that may corrode plastic.

Ensure that no liquid enters the system. Ensure that the ventilation areas of the server and the monitor are free.

Use a cloth for disinfection to clean the keyboard and the mouse.

Wipe the server and monitor casing with a dry cloth. If particularly dirty, use a cloth that has been moistened in a mild domestic detergent and then carefully wrung out.

Page 50: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens
Page 51: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 51

6 Problem Solutions and TipsV CAUTION!

Observe the safety information in the ”Safety“ manual and in chapter “Hardware Installation” on page 25.

If a problem occurs, try to resolve it as described:

– in this chapter,– in the documentation for the attached devices,– in the help systems of the software used.

If you fail to correct the problem, proceed as follows:

Ê Make a note of the steps and the circumstances that led to the fault. Note also any error message which may have been displayed.

Ê Switch the server OFF.

Ê Contact our Service organization (see “Warranty” in chapter “Related publi-cations” on page 63).

6.1 Power-ON Indicator Remains Dark

The power-ON indicator remains dark after switching ON:

Power cable not connected correctly

Ê Make sure that the power cable is correctly connected to the server and to the grounded power socket.

Power supply overloaded

Ê Pull the server power plug out of the insulated socket.

Ê Wait a few seconds and plug the power plug into the insulated socket again.

Ê Switch your server ON.

Page 52: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

52 U41615-J-Z156-1-76

The Server Switches Itself OFF Problem Solutions and Tips

6.2 The Server Switches Itself OFF

Server management has detected an error

Ê Check the error list or the ErrorLog file in the

ServerView

program, and attempt to eliminate the error.

6.3 The Monitor Remains Dark

Monitor is switched OFF

Ê Switch your monitor ON.

Power saving has been activated (screen is blank)

Ê Press any key on the keyboard.

or

Ê Deactivate screen blanking (screen saver). Enter the appropriate password.

Brightness control is set too dark

Ê Adjust the brightness control to increase the brightness. For detailed infor-mation, please refer to the operating manual supplied with your monitor.

Power cable or monitor cable not connected

Ê Switch OFF the monitor and the server.

Ê Check whether the power cable is properly connected to the monitor and to the power socket.

Ê Check whether the monitor cable is properly connected to the server and monitor (if it is connected with a plug). If a separate graphics card is installed in the server, then the monitor cable must be connected to the connection on this graphics card.

Ê Switch ON the monitor and the server.

Page 53: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 53

Problem Solutions and Tips Flickering Stripes Across the Monitor

6.4 Flickering Stripes Across the Monitor

V CAUTION!

Switch OFF the server immediately. Risk of damaging the server.

Monitor does not support the set horizontal frequency

Ê Find out which horizontal frequency your monitor supports. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor.

Ê Refer to the documentation for your operating system or to the corre-sponding software for the monitor controller for how to set the correct horizontal frequency for your monitor, and follow the procedure accordingly.

6.5 No Monitor Display or Display Drifts

The wrong horizontal frequency and/or resolution has been selected for the monitor or for the application program.

Ê Find out which horizontal frequency your monitor supports. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor.

Ê Refer to the documentation for your operating system or to the corre-sponding software for the monitor controller for how to set the correct horizontal frequency for your monitor, and follow the procedure accordingly.

6.6 No Mouse Pointer Displayed on the Monitor

Mouse driver not loaded

Ê Check whether the mouse driver is properly installed and is present when the application program is started. Detailed information can be found in the documentation for the mouse, the operating system, or the application program.

Page 54: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

54 U41615-J-Z156-1-76

Time and/or Date are Incorrect Problem Solutions and Tips

Mouse controller disabled

The mouse controller on the system board must be enabled if you use the supplied mouse.

Ê Check in the BIOS Setup whether the mouse controller is Enabled.

6.7 Time and/or Date are Incorrect

Ê Set the time and/or date in the operating system or in the BIOS Setup.

I If the time and date are repeatedly wrong when you switch on your server, you must change the lithium battery. Contact our Service group.

6.8 System Fails to Boot

The system will not boot after installing a new hard disk drive.

Ê Reboot the System with the ServerStart CD or with a boot CD and reconfigure the server (see section “Configuring the Server” on page 46).

6.9 Error Messages on the Monitor

The meanings of the error messages are explained in the manual for BIOS Setup and in the documentation for the relevant components and programs on the PRIMERGY ServerBooks CD.

Page 55: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 55

7 Property and Data ProtectionThe server is fitted with an intrusion detection switch which enables the ServerStart program to detect and log any removal of the cover.

The server is protected against unauthorized access by means of a lockable rack door.

To protect your system and data internally against unauthorized access, you can use the BIOS Setup security functions.

7.1 BIOS Setup security functions

The System Security menu in the BIOS Setup offers you various options for protecting your data from unauthorized access. By combining these options, you can achieve optimum protection for your system.

I You will find a detailed description of the System Security menu and how to assign passwords in the manual for the BIOS Setup on the ServerBooks CD (see also “Related publications” on page 63).

Preventing unauthorized BIOS Setup calls

You can activate this protection by setting a supervisor password in the System Security menu.

Preventing unauthorized system access

You can activate this protection by setting a user password in the System Security menu.

Preventing unauthorized writing of diskettes and/or of hard disk drives.

To activate this protection, select the value Write Protect All Sectors or Write Protect Boot Sector for Hard Disk Drive in the System Security menu.

Page 56: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens
Page 57: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 57

8 Hot-plug Hard Disk DrivesUp to two SATA hard disk drives can be installed in the PRIMERGY RX100 S3 server. There is a “hot-plug” and a “non hot-plug” variant of the server.

I If your server is a non hot-plug variant, this chapter does not apply to you.

Upgrading or replacing non hot-plug components is described in the “Options Guide” or in the Service Supplement and may only be performed by autorized, qualified staff.

The hot-plug hard disk drives are built on a carrier which allows defective drives to be replaced or new drives to be added during operation. The hard disk drive and the carrier constitute the hard disk drive module (called “HDD module” in the following sections).

This chapter describes how to handle hot-plug HDD modules (see page 58) and how to remove and install HDD modules (see page 59).

V CAUTION!

Only a service technician may remove a hard disk drive from the HDD module.

V CAUTION!

The HDD modules must be marked clearly so that they can be put back into their original place after an upgrade. If this is not taken into account, existing data can be destroyed.

V CAUTION!

The hot-plug function can only be performed together with a corre-sponding SATA RAID configuration.

Further information about SATA RAID configurations or RAID levels can be found in the SATA RAID controller documentation (see “Related publi-cations” on page 63).

Page 58: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

58 U41615-J-Z156-1-76

Handling HDD Modules Hot-plug Hard Disk Drives

8.1 Handling HDD Modules

The hard disk drives incorporated in the HDD modules are highly sensitive electromagnetic devices and must be handled with great care. It is extremely likely that an incorrect handling will lead to a partially and/or total failure of the hard disk drives.

These failures will result in data errors and to loss of data or to total destruction of the hard disk drive.

Please observe the following rules, which will help to avoid the occurrence of this type of problems:

● Store and transport HDD modules only within the limits stipulated in the specification.

● When transporting HDD modules (even over short distances), always use the original packaging (ESD labeling).

● Never expose a HDD module to a temperature shock. Avoid the formation of condensation inside and on the outside of the hard disk drives.

V CAUTION!

The HDD module must be acclimatized in its operating environment for an acclimatization time.

● Always put the HDD module down carefully, with its largest surface facing downwards, to avoid the danger of tipping over.

Temperature difference (°C)(operating

environment/outside)

Minimum acclimatization time (hours)

5 3

10 5

15 7

20 8

25 9

30 10

Table 6: Acclimatization time for the HDD module

Page 59: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 59

Hot-plug Hard Disk Drives Installing/Removing a HDD/Dummy Module

8.2 Installing/Removing a HDD/Dummy Module

Removing the dummy module

Free slots are provided with a dummy module (an empty carrier) which must be removed before installing an additional HDD module.

Figure 11: Removing the dummy module (hot-plug variant only)

Ê Press both tabs on the dummy module together (see figure 11) until the locking mechanism disengages, and remove the dummy module from the slot.

Installation of the dummy module occurs in reverse order.

V CAUTION!

Keep the dummy module for future use. If the HDD module is removed again and is not replaced with a new module, then the dummy module must be reinstalled due to cooling, the applicable EMC (electromagnetic compatibility) regulations and fire protection.

Page 60: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

60 U41615-J-Z156-1-76

Installing/Removing a HDD/Dummy Module Hot-plug Hard Disk Drives

Unlocking the HDD module

Figure 12: Unlocking the hot-plug HDD module

Ê Release the locking mechanism by pressing the locking button (1).

I If the HDD modules are provided with a transport lock (1 in figure 13), remove it before you release the locking mechanism.

Ê Push the handle of the HDD module fully in the direction of the arrow.

Figure 13: Hot-plug HDD module: releasing the transport lock

Page 61: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 61

Hot-plug Hard Disk Drives Installing/Removing a HDD/Dummy Module

Installing the HDD module

Figure 14: Installing the hot-plug HDD module

Ê Insert the HDD module with the opened handle carefully into the empty slot (1) until it stops.

Ê Push the module handle completely in the original position (2) until the locking mechanism engages.

Page 62: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

62 U41615-J-Z156-1-76

Installing/Removing a HDD/Dummy Module Hot-plug Hard Disk Drives

Swapping the HDD module

If you want to replace a hot-plug HDD module during operation, proceed as follows:

Ê Pull out the HDD module by a few centimeters.

V CAUTION!

Under no circumstances should you remove a HDD module while the system is in operation, if you are not sure that the hard disk drive is operated by a SATA RAID controller and belongs to a disk array which is operating in RAID level 1.

Only pull out a HDD module if the drive is not being accessed. Observe the control LEDs for the corresponding HDD module (see “Hard disk drive control indicators” on page 41).

Ê Wait for at least 60 seconds.

I This period is necessary for the SATA RAID controller to recognize that a HDD module has been pulled out and for the hard disk drive to come to a stop.

Ê Pull out the HDD module completely.

Ê Insert the new HDD module, as described in “Unlocking the HDD module” on page 60 and in “Installing the HDD module” on page 61.

V CAUTION!

If the HDD module is removed and not replaced with a new module, then the dummy module must be reinstalled due to cooling, the applicable EMC (electromagnetic compatibility) regulations and fire protection. Make sure that the retaining clips of the dummy unit engage correctly in the location.

Page 63: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 63

Literatur

Related publicationsManuals for PRIMERGY server systems are available as PDF files on the ServerBooks CD. The ServerBooks CD is part of the PRIMERGY ServerView Suite delivered with each server system.

The current versions of the required manuals can be downloaded free of charge as PDF files from the Internet. The overview page showing the online documen-tation available on the Internet can be found via the URL:http://manuals.fujitsu-siemens.com. For the documentation of the PRIMERGY servers choose the navigation point industry standard servers.

[1] Safety

[2] Ergonomics

[3] Warranty

[4] Returning used devices

[5] System Board D2004 Technical Manual

[6] BIOS Setup Reference Manual

[7] Quickstart Hardware - PRIMERGY RX100 S3 Poster

[8] Quickstart Software - PRIMERGY ServerView Suite Poster

[9] PRIMERGY RX100 S3 Server System Options Guide

[10] PRIMERGY ServerView Suite ServerStartUser Manual

[11] Global Array Manager Client Software User Manual

Page 64: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

64 U41615-J-Z156-1-76

Related publications

[12] Global Array Manager Server Software User Manual

[13] LSI SATA Software RAID User Manual

[14] PRIMECENTER Rack Technical Manual

[15] DataCenter Rack Technical Manual

[16] PRIMERGY ServerView Suite ServerView S2Server ManagementUser Manual

[17] PRIMERGY ServerView Suite ServerViewServer ManagementUser Manual

[18] PRIMERGY ServerView Suite RemoteViewUser Manual

Page 65: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 65

Index

3rd-Party Rackinstalling in 34requirements 29

Aacclimatization time 25, 58ASR&R 7availability 7

BBIOS

security functions 55BIOS Update 9button

identification 40

Ccables

connecting 38disconnecting 38

CD/DVD driveindicator 39

CE label 10, 20Class B Compliance Statement 20cleaning

monitor, mouse, server, keyboard 49

componentshardware/software 5

configuringserver 8, 46

connectingcables 38external devices 38

consumables 23correcting error 51

Ddata manipulation 5data protection 55DataCenter Rack

requirements 28delivery note 26devices

connecting to the server 36disconnecting

cables 38disposal, of devices 24dummy module

HDD module 59

EECC 7electrical data 10electromagnetic compatibility 10, 20EMC 10EMC regulations 59environmental conditions 11environmental protection 22error

display drifts 53flickering stripes on screen 53no mouse pointer 53screen remains dark 52server switches off 52system does not boot 54wrong date 54wrong time 54

Error Correcting Code 7error message

on screen 54ESD (devices sensitive to electrostatic

discharge) 19ESD-sensitive devices 19external devices

connecting 38

Page 66: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

66 U41615-J-Z156-1-76

Index

Ffault

display drifts 53screen dark 53system does not boot 54

FCC statement 20features 7Flash-EPROM 9floppy disk drive

indicator 41

GGlobal Error

indicator 41, 43graphic card 37

Hhard disk drive 7

carrier 57handling 58HDD module 57indicator 41online replacing 62

HDD busyindicator 39

HDD moduleacclimatization time 58carrier 59dummy module 57handling 57hard disk drive 59hot-swap 62installing/removing 59

hot-swapHDD module 62

Iidentification

button 40indicator 40, 43

indicatorhard disk drive 41

indicatorsCD/DVD 39Global Error 41, 43HDD busy 39identification 40, 43LAN 43on the server 39power-ON indicator 40, 51

informationadditional 6

installingserver 27

installing in3rd-Party Rack 34PRIMECENTER Rack 32

LLAN

indicator 43light-emitting diode (LED) 18lithium battery 18low-voltage directive 10, 20

Mmains voltage

connecting the server 37meaning of the symbols 9model rating plate 26monitor

display drifts 53flickering 53no display on screen 53screen dark 53

mounting kitserver 31

mouseno mouse pointer on the

screen 53

Page 67: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

U41615-J-Z156-1-76 67

Index

NNMI button 40noise level 11notational conventions 9note on the laser 18notes on safety 15

OON/OFF button 40operating elements 39operating system

installing 48operation 39operator panel 39overloading 8

Ppackaging 23, 26password

property protection 55supervisor 55user 55

PDA 7, 8ports 36

keyboard port 36LAN port 36monitor port 36mouse 36serial port 36USB port 36

power supply unitfixed 37

power-ON indicatordoes not light 51

PRIMECENTER Rackinstalling in 32requirements 28

property protection 55password 55

Rrack

requirements 28RAID controller

configuring 48recycling, of devices 24reliability 7RemoteView 9removing

server 27requirements

3rd-Party Rack 29DataCenter Rack 28PRIMECENTER Rack 28

reset button 40returning, of devices 24routing cables 33

Ssaving energy 22screen

error message 54flickering stripes 53remains dark 52

security functions 5supervisor password 55user password 55

serveracclimatization time 25configuring 46connecting external devices 36connecting mains voltage 37correcting error 51data protection 55dimensions 11electrical data 10environmental conditions 11fitting in the rack 27indicators 39, 40installing 27

Page 68: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

68 U41615-J-Z156-1-76

Index

keyboard port 36LAN port 36monitor port 36mounting kit 31mouse port 36NMI button 40noise level 11ON/OFF button 40operation 39operator panel 39ports 36property protection 55removing 27reset button 40routing cables 33safety standards 10serial port 36setting up 39standards 10suspend mode 45switches itself off (error) 52switching OFF 44switching ON 44technical data 10transport 21troubleshooting 51unpacking 26USB port 36ventilation clearance 11weight 11

server management 8ServerStart 8, 47ServerView 8

supported functions 8standards 10

sticker 23support bracket 32suspend mode 45switching OFF

server 44switching ON

server 44switch-OFF time

define 45switch-ON time

define 45System Architect 25System board 7system does not boot 54

Ttarget group 5technical data 10time, wrong 54transport damage 26troubleshooting, server 51

Uunpacking

server 26

Vventilation clearance 11

Wweight 11

Page 69: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

Comments on PRIMERGY RX100 S3Server System

U41615-J-Z156-1-76

CommentsSuggestionsCorrections

Submitted by

Fujitsu Siemens Computers GmbHUser Documentation81730 MünchenGermany

Fax: (++49) 700 / 372 00000

e-mail: [email protected]://manuals.fujitsu-siemens.com

Page 70: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens
Page 71: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

Comments on PRIMERGY RX100 S3Server System

U41615-J-Z156-1-76

CommentsSuggestionsCorrections

Submitted by

Fujitsu Siemens Computers GmbHUser Documentation81730 MünchenGermany

Fax: (++49) 700 / 372 00000

e-mail: [email protected]://manuals.fujitsu-siemens.com

Page 72: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens
Page 73: PRIMERGY RX100 S3 Server System - Fujitsumanuals.ts.fujitsu.com/file/3919/rx100s3-ba-en.pdf · PRIMERGY PRIMERGY RX100 S3 Server System Operating Manual Xenia Fierley Fujitsu Siemens

Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu-ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So-lutions.

This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.

Contact and support addresses will now be offered by Fujitsu Technology So-lutions and have the format …@ts.fujitsu.com.

The Internet pages of Fujitsu Technology Solutions are available at http://ts.fujitsu.com/... and the user documentation at http://manuals.ts.fujitsu.com.

Copyright Fujitsu Technology Solutions, 2009

Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit-dem den Namen Fujitsu Technology Solutions.

Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.

Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.

Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.

Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die Benutzerdokumentation.

Copyright Fujitsu Technology Solutions, 2009