11
| 1 FOR PROFESSIONALS Product Catalog A BONE ANCHORED FACIAL PROSTHETIC SOLUTION

Product Catalog - epitheses.orgProduct+Catalog.pdf · tightened to 25 Ncm. Cochlear Vistafix 3 Healing Abutment The healing abutment is used during healing and allows the clinician

Embed Size (px)

Citation preview

Page 1: Product Catalog - epitheses.orgProduct+Catalog.pdf · tightened to 25 Ncm. Cochlear Vistafix 3 Healing Abutment The healing abutment is used during healing and allows the clinician

| 1

FOR PROFESSIONALS

Product Catalog

A BONE ANCHORED FACIAL PROSTHETIC SOLUTION

Page 2: Product Catalog - epitheses.orgProduct+Catalog.pdf · tightened to 25 Ncm. Cochlear Vistafix 3 Healing Abutment The healing abutment is used during healing and allows the clinician

ContentsSterile products Vistafix 3 System 4

Sterile products Prior generation Vistafix 6

Prosthetic and lab components 8

Reusable instruments 12

Osscora surgical set and accessories 13

Compatibility of reusable instruments 14

Training equipment and accessories 15

Instrument and component guide Vistafix 3 System 16

Instrument and component guide Prior generation Vistafix 17

Retention component guide 18

Index 19

NOTE : • Imagesinthisguidearenottoscale. • Notallproductsareavailableinallmarkets.Productavailabilityissubjecttoregulatory approvalintherespectivemarkets.

The Cochlear™ Vistafix® 3 System consists of:

• CochlearVistafixVXI300Implant(Vistafix3Implant)• CochlearVistafixVXA300Abutment(Vistafix3Abutment)

The prior generation Vistafix System consists of:

• CochlearVistafixSTFixtures(flangeless)• Standardabutments

Page 3: Product Catalog - epitheses.orgProduct+Catalog.pdf · tightened to 25 Ncm. Cochlear Vistafix 3 Healing Abutment The healing abutment is used during healing and allows the clinician

| 54 |

Sterile productsAllimplants,abutmentsandcoverscrewsaremade oftitanium.Allsterileproductsareforsingleuseonly.

Cochlear Vistafix 3 ImplantsUsedforVistafixone-stageortwo-stagesurgery.

Cochlear Vistafix 3 AbutmentsTheVXA300Abutmentsareonlycompatible withVXI300Implants.

NOTE:TheVXA300Abutmentscrewsshouldbetightenedto25Ncm.

Cochlear Vistafix 3 Healing AbutmentThe healing abutment is used during healing and allowsthecliniciantoselectingafinalabutmentheightafterhealinghasoccurred,oncethefinaltissuethicknessisknown.Themarkingsonthehealing abutment can be used to indicate the thicknessofthesofttissue.Thehealingabutmentismountedontheimplant.

NOTE:TheVXA300Healingabutmentshouldbetightenedto25Ncm.

92994 VXA300 Abutment3.5mm 92995 VXA300Abutment4.5mm

92996 VXA300Abutment6mm 92997 VXA300Abutment7.5mm

93100 VXI300Implant 3mm,Ø4.5mm

93101VXI300Implant 4mm,Ø4.5mm

92998VXA300Healingabutment

Cover screw

NOTE:ThecoverscrewconicalisonlycompatiblewithVXI300Implants.

DrillsStainlesssteel.

NOTE:Theguidedrillhasaremovablespacerfordrillingtodifferentdepths.

WARNINg: Theguidedrillsandwideningdrillsfeaturedhereareonlycompatiblewiththe Vistafix3System,andCANNOTbeusedwith priorgenerationVistafixImplantsandFixtures.

Biopsy punch

NOTE:Thebiopsypunchisonlysoldinpacksof10.

Healing capThe healing cap is used to hold the dressing inplaceduringhealing.

93102Coverscrewconical forVistafixVXI300Implant

92139 Guide drill 3+4mm,Ø2.3mm

92141 Widening drill withcountersink4mm, Ø4.1mm

92140 Widening drill withcountersink3mm, Ø4.1mm

90802HealingcapØ14mm

90940BiopsypunchØ4mm

90801 HealingcapØ6.5mm

Vistafix 3 System

Page 4: Product Catalog - epitheses.orgProduct+Catalog.pdf · tightened to 25 Ncm. Cochlear Vistafix 3 Healing Abutment The healing abutment is used during healing and allows the clinician

| 76 |

Flangeless implantsImplantshaveamachinedtitanium surfaceandhexagonalconnection.

Healing abutment and healing caps

Cover screw

NOTE:CoverscrewisforpriorgenerationVistafixonly.

Instruments – reusable

90478 Connection to handpiece 90941 Abutmentclamp for counter-torque

90438 FixtureST 3mm,Ø3.75mm

90436 Healing abutment Unigrip 7 mm

90801 Healingcap Ø6.5mm

Standard abutments

NOTE: Standard abutments are only compatiblewithpriorgeneration Vistafix Implants

Drills

Instruments for limited space – reusable

90415 Guide drill 3+4mm,Ø1.8mm

90238 Fixturemount Unigrip short

90456 Screwdriver for hexagon 17 mm

90416 Drill countersink3mm, Ø3.3mm

90380 Drill Machine screwdriverUnigrip20mm

90459 Screwdriver Unigrip20mm

90417 Drill countersink4mm, Ø3.3mm

90453 Screwdriverfor internalhexagon20mm

90620 Coverscrew spacewithinternalhexagon

90780 Standard abutment 3 mm

90778 Standard abutment 4 mm

90776 Standard abutment5.5mm

90774 Standard abutment 7 mm

90440 FixtureST 4mm,Ø3.75mm

90802Healingcap Ø14mm

Sterile productsPrior generation Vistafix

Page 5: Product Catalog - epitheses.orgProduct+Catalog.pdf · tightened to 25 Ncm. Cochlear Vistafix 3 Healing Abutment The healing abutment is used during healing and allows the clinician

| 98 |

Prosthetic and lab componentsBarconstructioncomponents.

90446 Gold bar Ø2x50mm

Prosthetic components for Cochlear Vistafix 3 SystemDuringtheprostheticwork,thegoldbarissoldered to the gold cylinders and the clips incorporatedintheacrylicoftheprosthesis.

NOTE: The gold cylinder 4 mm can be ground down1mmtoa3mmgoldcylinder.Thegoldscrewshouldbetightenedto10Ncm.

NOTE:Forfullretentionforce,theclipattachmentshouldbeactivatedbycarefullycompressingthetwolamellae.

90338GoldscrewUnigrip for gold cylinder

Prosthetic lab components compatible with both Cochlear Vistafix 3 and prior generation Vistafix

90796 Guidepin20mm

93184 Gold cylinder 4 mm forVistafixVXA300

93192 Impression coping squared for VistafixVXA300

93185 Abutment replica for VistafixVXA300

90842 Clip attachmentØ2mm

90448 Gold bar Ø2x100mm

Prior generation Vistafix prosthetic components

90374 Abutment replica

90772 Gold cylinder 4 mm

90379 Impression coping squared

90794 Guidepin10mm

Page 6: Product Catalog - epitheses.orgProduct+Catalog.pdf · tightened to 25 Ncm. Cochlear Vistafix 3 Healing Abutment The healing abutment is used during healing and allows the clinician

| 1110 |

DeSCrIPTION PrODuCT ImAge

DeSCrIPTION PArT

NumBer

HeIgHT (mm)

DIAmeTer (mm)

reTeNTION

FOrCe (N)

AurICulAr mAgNeT Magnet for auricular magnacaps

MLL2-OR-S 2.7 5.5 19.4

PrOSTHeSIS mAgNeTS Micro magnetMini magnetMidi magnetMaxi magnet

M0-SM1-SM2-SM3-S

1.993.23.23.9

4.54.55.55.5

4.26.510.511.5

PrOSTHeSIS mAgNeTS (Lip design)

Micro lip magnetMini lip magnetMidi lip magnetMaxi lip magnet

ML0-SML 1-SML2-SML3-S

1.993.23.23.9

4.54.55.55.5

4.26.510.511.5

PrOSTHeSIS mAgNeTS (Long lip design)

Maxi long lip magnet MLL3-S 3.9 5.5 11.5

AurICulAr mAgNACAP for Vistafix 3 System

Auricularmaximagnacap for Vistafix 3 System

VF-MC2-OR-S 2.7 5.26

mAgNACAPS for Vistafix 3 System

Mini magnacap for Vistafix 3 System

Maxi magnacap for Vistafix 3 System

VF-MC1-S

VF-MC2-S

2.1

2.1

4.4

5.1

AurICulAr mAgNACAP for prior generation Vistafix

Auricularmaximagnacap for prior generation Vistafix

BMC2-OR-S 2.7 5.5*

mAgNACAPS for prior generation Vistafix

Mini magnacap for prior generation Vistafix Maxi magnacap for prior generation Vistafix

B-MC1-S

B-MC2-S

2.1

2.1

4.4

5.1

mAgNABuTmeNTS for prior generation Vistafix

Mini magnabutment Maxi magnabutments for prior generation Vistafix only

E-MA1-SE-MA2-S

3.63.6

4.45.1

Magnet components (manufactured by Technovent Ltd).

*Atfittingsurface.

DeSCrIPTION PrODuCT ImAge

DeSCrIPTION PArT NumBer

HeIgHT (mm) DIAmeTer (mm)

lAB COmPONeNTS Mini hand capfit toolMaxi hand capfit toolMini latch capfit toolMaxi latch capfit tool

CF1CF2CF3CF4

Transfer magnet MT1MT2

3.23.2

4.55.5

Lab analog capfor prior generation Vistafix

B-LAC1B-LAC2

2.12.1

4.45.1

Lab analog capfor Vistafix 3 System • Mini magnacap •Maximagnacap and auricular magnacap

V-LAC1V-LAC2

2.12.1

4.45.1

Lab analog abutment LAA1LAA2

2.53.5

4.45.1

Locator ringsfor prior generation Vistafix

LR1LR2

LR-LL2

Page 7: Product Catalog - epitheses.orgProduct+Catalog.pdf · tightened to 25 Ncm. Cochlear Vistafix 3 Healing Abutment The healing abutment is used during healing and allows the clinician

| 1312 |

reusable instruments

90381 Machine screwdriverUnigrip25 mm

90397 Machine screwdriverabutment

90459ScrewdriverUnigrip20mm

90944 Raspatorium

92142 Implant inserter

Osscora surgical set and accessoriesOsscora surgical setAlltheOsscorasurgicalsetsaredeliveredwith thefollowingarticles:• Motorwith3.5mcableincludingmotorprotective

cover,lockingpins(2pcs)andclips(10pcs)

• Osscoracontra-anglehandpieceincluding sprayclips(2pcs)andnozzlecleaner

• Irrigationtubingset(6pcs)

• FootcontrolS-N1

• Irrigationstand

• Powerable

91053 Osscora surgical set 115 V

AccessoriesThefollowingcomponentcanbeordered as an accessory to the Osscora surgical set:

91102 Sterilizationcassette

Spare partsThefollowingarticlescanbeorderedasspare parts for the Osscora surgical set:

91050 Osscorahandpiece20:1 91054 Osscora motor withcable3.5m

04032600 Motor protectivecover

91116 Drill indicator for WS-75 and Osscora

90943 Dissector

90469 ScrewdriverUnigrip 95 mm

92143 MultiwrenchwithISOadapter

92347 ISO adapter forMultiwrench.Spare part for Multi wrench. For compatibility with ISO instruments such as implant inserter.

92290 Square adapter forMultiwrench.For compatibility withfixture mount on implants with hexagonal connection.

92353 ISO adapter forsurgicalwrench.For compatibility with ISOinstruments such as implant inserter.

90408Screwdriverfor internal hexagon

93183 Counter torquewrenchforVistafixVXA300

90139 Surgical organizer

90146 Instrument organizer

Allinstrumentsareorderedindividually.Forinstrumentcompatibility,seepage14.Forcleaningandsterilizationguidelines please see the Vistafix Treatment and SurgeryGuide.

NOTE: The instruments in this page are used for the Vistafix3System.Inadditiontothis,thereareinstrumentsusedforthepriorgenerationimplantsystem,seepriorgenerationVistafix,page14.

Wrench adapters

Page 8: Product Catalog - epitheses.orgProduct+Catalog.pdf · tightened to 25 Ncm. Cochlear Vistafix 3 Healing Abutment The healing abutment is used during healing and allows the clinician

| 1514 |

Training equipment and accessories

Training equipment

Accessories

91040 Abutmentcleaningbrush

91153 ½Skullmodel withsofttissue

90643 ¼Skullmodel, plastic temporal bone

90644 ½Skullmodel,plastic temporal bone

92150 Dummy implant 4 mm

93385 Dummy VistafixVXA300Abutment6mm

Compatibility of reusable instruments

91050Osscorahandpiece20:1

92347 ISO adapter for Multiwrench

92353 ISO adapter for surgicalwrench

90478Connection to handpiece

90381Machinescrew-driverUnigrip25mm

92142 Implant inserter

VXI300Implant

92143Multiwrench

90338GoldscrewUnigrip for gold cylinder

Standard abutments withhexagonal

connection

Prior generation Vistafix series

VXA300Healingabutment

VXA300Abutment

NOTE: Theabovechartexplainscompatibilitybetweenbothnewandpriorgenerationsofinstruments.

90762Surgicalwrench

90397Machinescrewdriverabutment

90941Abutmentclamp

93183 Vistafix counter torquewrench

92290SquareadapterforMultiwrench

STfixturewith fixture mount

Prior generation Vistafix series

Page 9: Product Catalog - epitheses.orgProduct+Catalog.pdf · tightened to 25 Ncm. Cochlear Vistafix 3 Healing Abutment The healing abutment is used during healing and allows the clinician

| 1716 |

PATIENT COMPONENTS

VX

I300

Impl

ants

Cove

r scr

ewV

XA

300

Abu

tmen

tsH

ealin

g ca

p an

d ab

utm

ent

ASSOCIATED INSTRUMENTS

90802 Healingcap Ø14mm

92143 Multiwrenchwith

ISO adapter

Insertion

Instrument and component guide

93100 3 mm

93101 4 mm

92142 Implant inserter

93102 CoverscrewconicalforVistafixVXI300Implant

90459 ScrewdriverUnigrip

20mm

90469 Screwdriver

Unigrip 95 mm

92994 3.5mm

92995 4.5mm

92996 6 mm

92997 7.5mm

90397 Machinescrewdriver

abutment

93183 Counter torque wrenchfor

VistafixVXA300

90397 Machine screwdriverabutment

92998 VXA300Healing

abutment

93183 Counter torque wrenchfor

VistafixVXA300

90469 Screwdriver

Unigrip 95 mm

92143 Multiwrenchwith

ISO adapter

90459 Screwdriver

Unigrip20mm

92143 Multiwrenchwith

ISO adapter

LABORATORY COMPONENTS

gol

d cy

linde

r an

d go

ld s

crew

Impr

essi

on c

opin

gs

and

guid

e pi

ns

ASSOCIATED INSTRUMENTS

90794 Guide pin 10mm

90796 Guide pin 20mm

PATIENT COMPONENTS ASSOCIATED INSTRUMENTS

90469 Screwdriver

Unigrip 95 mm

90469 Screwdriver

Unigrip 95 mm

90469 Screwdriver

Unigrip 95 mm

90338 Goldscrew

Unigrip

93184 Gold cylinder

4 mm for Vistafix VXA300Abutment

90459 ScrewdriverUnigrip

20mm

90381 Machinescrew-driver

Unigrip 25 mm

93192 Impression

coping squared for

VistafixVXA300

93185 Abutmentreplica for

VistafixVXA300

92143 Multiwrenchwith

ISO adapter

LABORATORY COMPONENTS

gol

d cy

linde

r an

d go

ld s

crew

Impr

essi

on c

opin

gs

and

guid

e pi

ns

ASSOCIATED INSTRUMENTS

90794 Guide pin 10mm

90796 Guide pin 20mm

PATIENT COMPONENTS ASSOCIATED INSTRUMENTS

90381 Machinescrew-driver

Unigrip 25 mm

90469 Screwdriver

Unigrip 95 mm

90338 Goldscrew

Unigrip

90772 Gold cylinder

90459 ScrewdriverUnigrip

20mm

90379 Impression

coping squared

90374 Abutment

replica

Instrument and component guidePrior generation Vistafix

PATIENT COMPONENTS

Prio

r gen

erat

ion

V

ista

fix im

plan

tsPr

ior g

ener

atio

n

Vis

tafix

Abu

tmen

tsH

ealin

g ca

p an

d

abut

men

t

ASSOCIATED INSTRUMENTS

FOR TIgHTENINgFOR TIgHTENINg

FOR HEALINg CAPFOR HEALINg CAP

FOR COUNTER TORqUEFOR COUNTER TORqUE

90802 Healingcap Ø14mm

92143 Multiwrenchwith

ISO adapter

FOR HEALINg ABUTmENT

90438 3mm,

Ø3.75mm

90440 4mm,

Ø3.75mm

90397 Machinescrewdriver

abutment

90941 Abutmentclamp

90436 Prior generation

Healingabutment

90469 Screwdriver

Unigrip 95 mm

92143 Multiwrenchwith

ISO adapter

90459 Screwdriver

Unigrip20mm

ImPOrTANT: Only the listedguide drills are compatible with the prior generation Vistafix implants. The guide drill and countersink drills CANNOT be used with the Vistafix 3 System implants.

90417 Countersink 4mm,

Ø3.3mm

90416 Countersink 3mm,

Ø3.3mm

90478 Connection to

handpiece

Cove

r scr

ew

90620 Coverscrewspacewith

internal hexaon

90453 Screwdriver

for internal hexagon

90780 3 mm

90778 4 mm

90776 5.5mm

90774 7 mm

90941 Abutmentclamp

90415 3+4mm, Ø1.8mm

Vistafix 3 System

FOR INSERTIONImPOrTANT: Only the listedguide drills are compatible with the Vistafix 3 Systemimplants. The guide drill andwidening drills CANNOT beused with the prior generation Vistafix implants.

92139 Guide drill 3+4mm, Ø2.3mm

92140 Widening drill withcountersink 3mm,Ø4.1mm

92141 Widening drill withcountersink 4mm,Ø4.5mm

FOR HEALINg ABUTmENT

90381 Machinescrew-driver

Unigrip 25 mm

Page 10: Product Catalog - epitheses.orgProduct+Catalog.pdf · tightened to 25 Ncm. Cochlear Vistafix 3 Healing Abutment The healing abutment is used during healing and allows the clinician

| 1918 |

retention component guidePART NAME PART NUMBER PAGE

¼Skullmodel,plastictemporalbone 90643 15

½Skullmodelwithsofttissue 91153 15

½Skullmodel,plastictemporalbone 90644 15

Abutmentclamp 90941 7

Abutmentreplica 90374 8

AbutmentreplicaforVistafixVXA300 93185 8

Auricularmagnet MLL2-OR-S 10

Auricularmaximagnacap,forpriorgenerationVistafix BMC2-OR-S 10

Auricularmaximagnacap,forVistafix3System VF-MC2-OR-S 10

BiopsypunchØ4mm 90940 5

Cleaningbrush 91040 15

Connectiontohandpiece 90478 14

CountertorquewrenchforVistafixVXA300 93183 12

CoverscrewconicalforVistafixVXI300Implant 93102 5

Coverscrewspacewithinternalhexagon 90620 6

Dissector 90943 12

Drillcountersink3mm 90416 6

Drillcountersink4mm 90417 6

Drill indicator for WS-75 and Osscora 91116 12

DummyImplant4mm 92150 15

DummyVistafix3Abutment 93385 15

FixturemountUnigripshort 90238 7

FixtureST3mm,flangeless 90438 6

FixtureST4mm,flangeless 90440 6

GoldbarØ2x100mm 90448 9

GoldbarØ2x50mm 90446 9

Goldcylinder4mmforpriorgenerationVistafix 90772 8

Goldcylinder4mmforVistafixVXA300 93184 8

GoldscrewUnigripforgoldcylinder 90338 9

Guidedrill3+4mmØ1.8mmforpriorgenerationVistafix 90415 6

Guidedrill3+4mmØ2.3mm 92139 5

Guidepin10mm 90794 9

Guidepin20mm 90796 9

HealingabutmentUnigrip7mm 90436 7

HealingcapØ14mm 90802 7

HealingcapØ6.5mm 90801 7

Implant inserter 92142 12

Impressioncopingsquared 90379 8

ImpressioncopingsquaredforVistafixVXA300 93192 8

Instrumentorganizer 90146 12

ISOadapterforMultiwrench 92347 12

ISOadapterforsurgicalwrench 92353 12

Labanalogabutment LAA1 11

Labanalogabutment LAA2 11

LabanalogcapforpriorgenerationVistafix B-LAC1 11

LabanalogcapforpriorgenerationVistafix B-LAC2 11

LabanalogmaximagnacapforVistafix3System V-LAC2 11

LabanalogminimagnacapforVistafix3System V-LAC1 11

Locator rings for prior generation Vistafix LR1 11

Locator rings for prior generation Vistafix LR2 11

Locator rings for prior generation Vistafix LR-LL2 11

Machinescrewdriverabutment 90397 12

MachinescrewdriverUnigrip20mm 90380 12

MachinescrewdriverUnigrip25mm 90381 12

Maxihandcapfittool CF2 11

Maxilatchcapfittool CF4 11

Maxilipmagnet ML3-S 10

Maxilonglipmagnet MLL3-S 10

MaximagnabutmentsforpriorgenerationVistafixonly E-MA2-S 10

MaximagnacapforpriorgenerationVistafix B-MC2-S 10

IndexPART NAME PART NUMBER PAGE

MaximagnacapforVistafix3System VF-MC2-S 10

Maximagnet M3-S 10

Microlipmagnet ML0-S 10

Micromagnet M0-S 10

Midilipmagnet ML2-S 10

Midimagnet M2-S 10

Minihandcapfittool CF1 11

Minilatchcapfittool CF3 11

Minilipmagnet ML1-S 10

MinimagnabutmentforpriorgenerationVistafixonly E-MA1-S 10

MinimagnacapforpriorgenerationVistafix B-MC1-S 10

MinimagnacapforVistafix3System VF-MC1-S 10

Minimagnet M1-S 10

Motorprotectivecover 4032600 13

MultiwrenchwithISOadapter 92143 12

Osscorahandpiece20:1 91050 13

Osscoramotorwithcable3.5m 91054 13

Osscorasurgicalset115V(US,Canada) 91053 13

Raspatorium 90944 12

Screwdriverforhexagon 90408 12

Screwdriverforhexagon17mm 90456 7

Screwdriverforinternalhexagon20mm 90453 7

ScrewdriverUnigrip20mm 90459 7

ScrewdriverUnigrip95mm 90469 12

SquareadapterforMultiwrench 92290 12

Standardabutment3mm 90780 6

Standardabutment4mm 90778 6

Standardabutment5.5mm 90776 6

Standardabutment7mm 90774 6

Sterilizationcassette 91102 13

Surgicalorganizer 90139 8

Transfer magnet MT1 11

Transfer magnet MT2 11

VXA300Abutment4.5mm 92995 4

VXA300Abutment6mm 92996 4

VXA300Abutment7.5mm 92997 4

VXA300Abutment3.5mm 92994 4

VXA300Healingabutment 92998 4

VXI300Implant3mm 93100 4

VXI300Implant4mm 93101 4

Wideningdrillwithcountersink3mm 92140 5

Wideningdrillwithcountersink4mm 92141 5

*Seewww.technovent.com

93101 4 mm

93100 3 mm

92994 3.5mm

92995 4.5mm

92996 6 mm

92997 7.5mm

93184 Gold cylinder

4 mm for VistafixVXA300

BAR RETENTION

90338 Goldscrew

Unigrip

90842 Clip attachment

Ø2mm

90446 or 90448

Gold bar Ø2x50mm Ø2x100mm

MAGNET RETENTION*

VF-mC1-S VF-mC2-S

Magnacaps for Vistafix 3 System*

mll2-Or-S Auricularmagnet

VF-mC2-Or-S Auricular

magnacap for Vistafix 3 System

m0-Sm3-S ml0-Sml3-S

mll3-S Prosthesis magnets*

MAGNET RETENTION*

mll2-Or-S Auricularmagnet

B-mC2-S Auricular

magnacap for prior generation Vistafix

mm0-S m0-Sm3-S

ml0-Sml3-S mll3-S

Prosthesis magnets*

mC1-S mC2-S

Magnacap

e-mA1-S e-mA2-S

Magnabutment

90772 Gold cylinder

for prior generation Vistafix

90440 4 mm

90438 3 mm

STANDARD ABUTmENTS FOR PRIOR gENERATION VISTAFIx ImPLANTSVxA300 ABUTmENTS

PRIOR gENERATION VISTAFIx ImPLANTSVxI300 ImPLANTS

90780 3mm

90778 4mm

90776 5.5mm

90774 7 mm

Prior generation VistafixUniversalVistafix 3 System

Page 11: Product Catalog - epitheses.orgProduct+Catalog.pdf · tightened to 25 Ncm. Cochlear Vistafix 3 Healing Abutment The healing abutment is used during healing and allows the clinician

VFX002 ISS1 JUN12

Cochlear Americas13059EastPeakviewAvenueCentennial,CO80111USA

Telephone: 13037909010Support: 18004833123WebChat: www.CochlearAmericas.com

Cochlear Canada Inc2500-120AdelaideStreetWestToronto,ONM5H1T1Canada

Telephone: 14169725082Fax: 14169725083

©2012 Cochlear Limited. All rights reserved. Trademarks and registered trademarks are the property of Cochlear Limited or Cochlear Bone Anchored Solutions. The names of actual companies and products mentioned herein may be the trademarks of their respective owners.

www.CochlearAmericas.com

Asyourpatient’spartner,Cochlearbelievesitisimportanttoconveynotonlythebenefits,butalsothepotentialrisksassociatedwithaCochlearVistafixprocedure.

Vistafixiscontraindicatedinpatientswithinadequatebonequalityorquantitytoprovidestabilityandsupportfortheimplant,orinpatientswhowillbeunabletomaintainandcleantheskinaroundtheabutment.IntheU.S.andCanada,useoftheimplantedfixture isalsocontraindicatedinchildrenunderagefiveyears.

Allsurgicalproceduresincludeanelementofrisk,anditisimpossibletoguaranteesuccess.Thedevicemayfailtoosseointegrateforanumberofreasons,includingphysiologicalandsurgicalissuesaswellastraumaticimpacttotheimplantsite.Onrareoccasionstheskinaroundtheabutmentmaybecomeinflamedfromamildinfectionortheskinmaygrowbacktowardsitsoriginalthickness.ForcompleteinformationregardingtherisksandbenefitsofaVistafixprocedure,pleaserefertotheInstructionsforusefortheVistafiximplantavailableatwww.CochlearAmericas.com/VistafixIndications