1
Yokogawa Technical Report English Edition Vol. 60 No. 2 (2017) New Products 71 123 Wireless communication offers various advantages including a substantial reduction of wiring costs, and is widely used for production facilities in plants. In addition, the technology is increasingly being used in safety facilities. Since wireless systems can satisfy the following needs, they are strongly recommended for gas detection systems in plants. Gas detection systems are easily affected by various factors such as installation location and ambient conditions. Even after installation, it is necessary to optimize the configuration by adding detectors or changing their locations. It is also necessary to install detectors in inaccessible places for wiring. In floating production, storage and offloading systems (FPSO) and offshore platforms, priority is given to light weight and small footprint, and so cabling also needs to be reduced. The ProSafe-RS SIL2 wireless gas detection system released in November 2017 consists of the ProSafe-RS R4.03.10 safety instrumented system to meet the safety integrity level (SIL) 3 requirements defined in the IEC61508 international standard, Yokogawa’s ISA100 Wireless-based system, and GasSecure AS i GS01 or GS01-EA wireless gas detectors. The GS01 and GS01-EA are the only wireless gas detectors in the industry that satisfy SIL2 requirements. The safety control station (SCS) of ProSafe-RS receives gas concentration data from the GS01 and GS01-EA via safety communication, and these data can be treated as input data of safety application (safety loop). MAJOR FEATURES Total system support The ProSafe-RS SIL2 wireless gas detection system is suitable for fire and gas systems or emergency shutdown systems thanks to its achievement of SIL2 requirements for risk reduction. Based on its knowledge of each component of this system and its expertise in production control, safety instrumentation, and field wireless engineering and consulting, Yokogawa is able to offer total system solutions, including customer support. Enhanced operating and maintenance efficiency The operation and monitoring screen of Yokogawa’s CENTUM VP integrated production control system shows the standard faceplate for all fire and gas sensors, including wireless/wired gas, flame, smoke and heat detectors, to maintain operating consistency and avoid mis-operation. In addition, information on the status of all network devices, the remaining charge level of gas detector batteries, and the status of wireless communication is easily monitored, enabling operators to quickly recognize and respond to any abnormality. i A subsidiary of Drägerwerk AG & Co. KGaA in Germany Example of system configuration MAJOR SPECIFICATIONS OF SAFETY COMMUNICATION FUNCTION Fire and gas communication function The fire and gas communication function acquires gas concentration data from wireless gas detectors via the S2LP131 Fire and Gas Communication Module mounted on the SCS, and the field wireless system complies with the ISA100.11a standards. Safety communication function The SCS and GS01/GS01-EA use the PROFIsafe protocol, which complies with SIL3, for the safety layer of communication. This protocol enables secure transmission of safety data between these devices. The SIL2-compliant system including communication is built based on this mechanism. Contact us: International System Sales Department, System Sales Center, IA System & Service BHQ URL: https://www.yokogawa.com/solutions/products-platforms/ control-system/safety-instrumented-systems-sis/ For worldwide locations, please see the back cover. * YFGW, CENTUM, and ProSafe are the registered trademarks of Yokogawa Electric Corporation. * All other company names and product names that appear in this page are either trademarks or registered trademarks of their respective holders. Human machine interface CENTUM VP HIS Safety engineering station ProSafe-RS SENG Safety control station ProSafe-RS SCS Field wireless management station YFGW410 Field wireless access point YFGW510 SIL2 wireless gas detector GasSecure GS01, GS01-EA Table 1 Basic specifications of fire & gas communication function Item Specifications Number of S2LP131 units to be mounted Max. 8 units/SCS Number of field wireless management stations (YFGW410) to be connected Max. 128 devices / S2LP131 Number of wireless field devices (GS01/GS01-EA) to be connected Max. 60 devices / S2LP131 Max. 320 devices / SCS YFGW410/YFGW510 S2LP131 SCS Safety application PROFIsafe ESB Bus ESB Bus PROFINET PROFINET ISA100.11a GS01 Safety application PROFIsafe ISA100.11a ESB Bus communication Field wireless communication (ISA100.11a) PROFINET communication PROFIsafe communication ProSafe-RS SIL2 Wireless Gas Detection System –Offering total system support including both consulting and engineering–

ProSafe-RS SIL2 Wireless Gas Detection System...Total system support The ProSafe-RS SIL2 wireless gas detection system is suitable for fire and gas systems or emergency shutdown systems

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ProSafe-RS SIL2 Wireless Gas Detection System...Total system support The ProSafe-RS SIL2 wireless gas detection system is suitable for fire and gas systems or emergency shutdown systems

Yokogawa Technical Report English Edition Vol. 60 No. 2 (2017)

New Products

71 123

Wireless communication offers various advantages including a substantial reduction of wiring costs, and is widely used for production facilities in plants. In addition, the technology is increasingly being used in safety facilities.

Since wireless systems can satisfy the following needs, they are strongly recommended for gas detection systems in plants.

• Gas detection systems are easily affected by various factors such as installation location and ambient conditions. Even after installation, it is necessary to optimize the configuration by adding detectors or changing their locations. It is also necessary to install detectors in inaccessible places for wiring.

• In floating production, storage and offloading systems (FPSO) and offshore platforms, priority is given to light weight and small footprint, and so cabling also needs to be reduced.

The ProSafe-RS SIL2 wireless gas detection system released in November 2017 consists of the ProSafe-RS R4.03.10 safety instrumented system to meet the safety integrity level (SIL) 3 requirements defined in the IEC61508 international standard, Yokogawa’s ISA100 Wireless-based system, and GasSecure AS i GS01 or GS01-EA wireless gas detectors. The GS01 and GS01-EA are the only wireless gas detectors in the industry that satisfy SIL2 requirements.

The safety control station (SCS) of ProSafe-RS receives gas concentration data from the GS01 and GS01-EA via safety communication, and these data can be treated as input data of safety application (safety loop).

MAJOR FEATURES

� Total system supportThe ProSafe-RS SIL2 wireless gas detection system is suitable for fire and gas systems or emergency shutdown systems thanks to its achievement of SIL2 requirements for risk reduction. Based on its knowledge of each component of this system and its expertise in production control, safety instrumentation, and field wireless engineering and consulting, Yokogawa is able to offer total system solutions, including customer support.

� Enhanced operating and maintenance efficiencyThe operation and monitoring screen of Yokogawa’s CENTUM VP integrated production control system shows the standard faceplate for all fire and gas sensors, including wireless/wired gas, flame, smoke and heat detectors, to maintain operating consistency and avoid mis-operation. In addition, information on the status of all network devices, the remaining charge level of gas detector batteries, and the status of wireless communication is easily monitored, enabling operators to quickly recognize and respond to any abnormality.

i A subsidiary of Drägerwerk AG & Co. KGaA in Germany

Example of system configuration

MAJOR SPECIFICATIONS OF SAFETY COMMUNICATION FUNCTION

● Fire and gas communication functionThe f ire and gas communication function acquires gas concentration data from wireless gas detectors via the S2LP131 Fire and Gas Communication Module mounted on the SCS, and the field wireless system complies with the ISA100.11a standards.

● Safety communication functionThe SCS and GS01/GS01-EA use the PROFIsafe protocol, wh ich compl ie s w it h SI L3, for t he sa fe t y laye r of communication. This protocol enables secure transmission of safety data between these devices. The SIL2-compliant system including communication is built based on this mechanism.

Contact us:International System Sales Department, System Sales Center, IA System & Service BHQ

URL: https://www.yokogawa.com/solutions/products-platforms/control-system/safety-instrumented-systems-sis/

For worldwide locations, please see the back cover.

* YFGW, CENTUM, and ProSafe are the registered trademarks of Yokogawa Electric Corporation.

* All other company names and product names that appear in this page are either trademarks or registered trademarks of their respective holders.

Human machine interfaceCENTUM VP HIS

Safety engineering stationProSafe-RS SENG

Safety control stationProSafe-RS SCS

Field wireless management stationYFGW410

Field wireless access pointYFGW510

SIL2 wireless gas detectorGasSecure GS01, GS01-EA

Table 1 Basic specifications of fire & gas communication functionItem Specifications

Number of S2LP131 units to be mounted Max. 8 units/SCSNumber of field wireless management stations (YFGW410) to be connected

Max. 128 devices / S2LP131

Number of wireless field devices (GS01/GS01-EA) to be connected

Max. 60 devices / S2LP131Max. 320 devices / SCS

YFGW410/YFGW510S2LP131

SCS

Safety application

PROFIsafe

ESB Bus ESB Bus PROFINET PROFINET ISA100.11a

GS01

Safety application

PROFIsafe

ISA100.11a

ESB Bus communication Field wireless communication (ISA100.11a)

PROFINET communication

PROFIsafe communication

ProSafe-RS SIL2 Wireless Gas Detection System–Offering total system support including both consulting and engineering–