Upload
anonymous-3mrwroq
View
329
Download
14
Embed Size (px)
Citation preview
7/23/2019 radiosondaje vaisala
1/88
GETTING STARTED GUIDE
Vaisala DigiCORA Sounding SystemMW41
M211429EN-E
7/23/2019 radiosondaje vaisala
2/88
PUBLISHED BY
Vaisala Oyj
Street address: Vanha Nurmijrventie 21, FI-01670 Vantaa, Finland
Mailing address: P.O. Box 26, FI-00421 Helsinki, Finland
Phone: +358 9 8949 1
Fax: +358 9 8949 2227
Visit our Internet pages atwww.vaisala.com.
Vaisala 2014
No part of this manual may be reproduced, published or publicly displayed in any form
or by any means, electronic or mechanical (including photocopying), nor may its
contents be modified, translated, adapted, sold or disclosed to a third party without priorwritten permission of the copyright holder. Translated manuals and translated portions
of multilingual documents are based on the original English versions. In ambiguous
cases, the English versions are applicable, not the translations.
The contents of this manual are subject to change without prior notice.
This manual does not create any legally binding obligations for Vaisala towards
customers or end users. All legally binding obligations and agreements are included
exclusively in the applicable supply contract or the General Conditions of Sale and
General Conditions of Service of Vaisala.
http://www.vaisala.com/http://www.vaisala.com/http://www.vaisala.com/http://www.vaisala.com/7/23/2019 radiosondaje vaisala
3/88
_________________________________________________________________________________
VAISALA _________________________________________________________________________ 1
Table of Contents
CHAPTER 1
GENERAL INFORMATION ............................................................................ 5
About This Manual ................................................................... 5Contents of This Manual ....................................................... 5Version Information ............................................................... 6Related Manuals ................................................................... 6
Documentation Conventions ................................................. 7
Safety ......................................................................................... 7ESD Protection ...................................................................... 7
Recycling .................................................................................. 8
Trademarks ............................................................................... 8
License Agreement .................................................................. 8
Warranty .................................................................................... 9
Technical Support .................................................................... 9
Product Returns ....................................................................... 9
CHAPTER 2
PRODUCT OVERVIEW ................................................................................ 11
Introduction to Vaisala DigiCORA Sounding SystemMW41 ....................................................................................... 11
Sounding Station Setup Summary ....................................... 14
CHAPTER 3
SELECTING LOCATION.............................................................................. 15
Sounding Operation Room.................................................... 15
Antennas ................................................................................. 16
Antenna Types .................................................................... 16Antenna Cables ................................................................... 17
Balloon-Filling Shed ............................................................... 17
CHAPTER 4
INSTALLING HARDWARE .......................................................................... 19
MW41 Sounding Workstation Requirements ...................... 19Operating System Compliance ........................................... 19Web Browser Compliance ................................................... 19Minimum Hardware Requirements...................................... 19
Using Uninterruptible Power System (UPS, Optional) withMW41 .................................................................................. 20
Sounding Processing Subsystem SPS311 .......................... 21Connecting Sounding Processing Subsystem SPS311 ...... 21
Power Supply and Grounding for SPS311 .......................... 23Switching the Power On and Off .................................... 23
7/23/2019 radiosondaje vaisala
4/88
Getting Started Guide ________________________________________________________________
2 ____________________________________________________________________ M211429EN-E
CHAPTER 5
INSTALLING SOFTWARE ........................................................................... 25
Operating System Settings .................................................... 25User Requirements for Installing the Software .................... 25
Dividing Workstation's Hard Disk ........................................ 26
Installing Peripheral Devices................................................. 26
Serial Port Extension ........................................................... 26Printer .................................................................................. 26
Installing MW41 Sounding System Software ....................... 27
Requirements for Installing MW41 in Windows 8.1Operating System ................................................................ 27
Internet Connection Available ........................................ 27No Internet Connection Available ................................... 28
Beginning MW41 Software Installation ................................ 29
Installing Flash Player to Windows 8.1 OperatingSystem ................................................................................. 29Installing Flash Player to Other Operating Systems ........... 29
Software License ................................................................. 30
1. Using a Trial Version ............................................... 302. Activating Software License .................................... 30
Installing MW41 Sounding Software and ActivatingSoftware License ................................................................. 31
Launching Vaisala License Manager ........................ 34Activating the License - Internet ConnectionAvailable ......................................................................... 35Activating the License - No Internet ConnectionAvailable ......................................................................... 37
Installing Security Certificate ................................................ 44
Adding MW41 Address to Trusted Sites ............................. 44
Installation Steps ................................................................. 44
CHAPTER 6
CREATING CONNECTIONS ........................................................................ 51
Connecting SPS311 ................................................................ 51
Using Firewall ...................................................................... 52Windows Firewall ........................................................... 52Other Firewalls ............................................................... 52
Changing SPS311 IP Address ............................................ 52
Connecting to SPS311 ................................................... 52Connecting with VNC ................................................ 52Connecting with PuTTY ............................................ 53
Using RegConfig to Change the SPS311 IP Address ......... 58
Changing the Administrator Password on SPS311 ....... 59
Connecting Ground Check Device RI41 ............................... 59
Ground Check Set GC25 ........................................................ 60Connecting Ground Check Set GC25 ................................. 60
Filling the Desiccant ............................................................ 60
Filling the GC25 Chamber with Desiccant........................... 61
Creating Remote Connection ................................................ 64Creating Trusted HTTPS Connection .................................. 64
Creating Trusted HTTPS Connection with InternetExplorer .......................................................................... 64Creating Trusted HTTPS Connection with Firefox ......... 65Creating Trusted HTTPS Connection with GoogleChrome ........................................................................... 76
7/23/2019 radiosondaje vaisala
5/88
_________________________________________________________________________________
VAISALA _________________________________________________________________________ 3
CHAPTER 7
STARTING THE SOUNDING SOFTWARE ................................................. 77
Starting the MW41 Software and Logging In ....................... 77
Managing MW41 Users .......................................................... 79
Default Users and Passwords ............................................. 79
Configuring Software ............................................................. 80
Creating System Backup ....................................................... 81
Logging Out ............................................................................ 81
APPENDIX A
MW41 SYSTEM ARCHITECTURE .............................................................. 83
List of Figures
Figure 1
DigiCORA Sounding System MW41 Overview with RS41 ...... 12
Figure 2 DigiCORA Sounding System MW41 Overview with RS92 ...... 13Figure 3 Signal Path Line-of-Sight Requirement .................................... 16Figure 4
MW41 Connections .................................................................. 22
Figure 5 Downloading and Installing .NET Framework 3.5 .................... 28Figure 6 Adobe Flash Player Installation Error Message ....................... 29Figure 7
Activating Product .................................................................... 35
Figure 8 Entering Product Key ............................................................... 35Figure 9 List of Activated Features ......................................................... 36Figure 10 Activating Product .................................................................... 37Figure 11
Entering Product Key ............................................................... 37
Figure 12 No Internet Connection is Available ......................................... 38Figure 13 License Manager Login Window .............................................. 38Figure 14
Viewing Product Details ........................................................... 39
Figure 15 Generating License File ........................................................... 39Figure 16 License File Successfully Generated ....................................... 40Figure 17 Uploading License File ............................................................. 41Figure 18
Opening License File ................................................................ 41
Figure 19 License File Successfully Uploaded ......................................... 42Figure 20 Displaying Installed Features ................................................... 42Figure 21
Taking Out the Desiccant Cartridge ......................................... 61
Figure 22 Opening the Desiccant Cartridge ............................................. 62Figure 23 Filling the Desiccant Cartridge ................................................. 63Figure 24
Using Security Certificate with Google Chrome ....................... 76
Figure 25
Sounding System MW41 System Architecture ........................ 85
List of Tables
Table 1 Manual Revisions ....................................................................... 6Table 2
Related Manuals ........................................................................ 6
Table 3 SPS311 Parameter Settings .................................................... 58Table 4 MW41 User Roles .................................................................... 79Table 5
MW41 Default Users and Passwords ...................................... 79
7/23/2019 radiosondaje vaisala
6/88
Getting Started Guide ________________________________________________________________
4 ____________________________________________________________________ M211429EN-E
This page intentionally left blank.
7/23/2019 radiosondaje vaisala
7/88
Chapter 1 _________________________________________________________ General Information
VAISALA _________________________________________________________________________ 5
CHAPTER 1
GENERAL INFORMATION
This chapter provides general notes about this manual and Sounding
System MW41.
About This Manual
This manual provides information for installing Sounding SystemMW41.
For information on maintaining the sounding system, see Vaisala
DigiCORA Sounding System MW41 Technical Reference. For operating
instructions, see the on-line help embedded in the sounding software.
NOTE In this manual, RS41 refers to Radiosonde RS41-SG and RS41-SGP,unless otherwise mentioned. RS92 refers to Radiosonde RS92-SGP,
unless otherwise mentioned.
RI41 refers to both RI41 and RI41-B, unless otherwise mentioned.
Contents of This Manual
This manual consists of the following chapters:
- Chapter 1,General Information, provides general notes about this
manual and Sounding System MW41.
- Chapter 2, Product Overview,introduces the Vaisala DigiCORA
Sounding System MW41 features.
- Chapter 3, Selecting Location, contains information on how to find a
suitable location for MW41 Sounding System.
- Chapter 4, Installing Hardware, provides information on the
DigiCORA MW41 hardware setup.
- Chapter 5, Installing Software, provides information on how to install
the required software for Sounding System MW41.
- Chapter 6, Creating Connections, contains instructions on how to
connect the MW41 Sounding System components.
7/23/2019 radiosondaje vaisala
8/88
Getting Started Guide ________________________________________________________________
6 ____________________________________________________________________ M211429EN-E
- Chapter 7, Starting the Sounding Software, provides information on
what to do after you have completed the mechanical and software
installations.
- Appendix ApresentsMW41 System Architecture with optional
components.
Version Information
Table 1 Manual Revisions
Manual Code Description
M211429EN-E November 2014. Updated for MW41 softwareversion 2.2 and RS41-SGP.
M211429EN-D February 2014. Updated for MW41 softwareversion 2.1.
M211429EN-C October 2013. Updated for Radiosonde RS41-SG
and MW41 sounding software version 2.0.M211429EN-B December 2012. Updated version for software
version 1.1.
M211429EN-A June 2012. First version.
Related Manuals
Table 2 Related Manuals
Manual Code Manual Name
M210843EN Vaisala Portable Antenna Set CG31 User's Guide
M210538EN Vaisala Telemetry Antenna RB31 User's Guide
M210814EN Vaisala Telemetry Antenna RM32 Quick ReferenceGuide
M210546EN Vaisala GPS Antenna GA31 User's Guide
M211030EN Vaisala GPS Antenna GA31N Users Guide
M211633EN Vaisala GPS Antenna GA41 Users Guide
M211381EN Backing Up and Restoring Windows 7 forMW31/MW41 Sounding System
M211596EN Sounding Processing Subsystem SPS311Technical Reference
7/23/2019 radiosondaje vaisala
9/88
Chapter 1 _________________________________________________________ General Information
VAISALA _________________________________________________________________________ 7
Documentation Conventions
Throughout the manual, important safety considerations are highlighted
as follows:
WARNING Warning alerts you to a serious hazard. If you do not read and followinstructions very carefully at this point, there is a risk of injury or even
death.
CAUTION Caution warns you of a potential hazard. If you do not read and followinstructions carefully at this point, the product could be damaged or
important data could be lost.
NOTE Note highlights important information on using the product.
Safety
Sounding System MW41 delivered to you has been tested for safety and
approved as shipped from the factory. Note the following precautions:
WARNING Ground the product and verify outdoor installation groundingperiodically to minimize shock hazard.
CAUTION Do not modify the unit. Improper modification can damage the productor lead to malfunction.
ESD Protection
Electrostatic Discharge (ESD) can cause immediate or latent damage to
electronic circuits. Vaisala products are adequately protected against
ESD for their intended use. It is possible to damage the product,
however, by delivering electrostatic discharges when touching,
removing, or inserting any objects inside the equipment housing.
To make sure you are not delivering high static voltages yourself:
- Handle ESD sensitive components on a properly grounded and
protected ESD workbench.
7/23/2019 radiosondaje vaisala
10/88
Getting Started Guide ________________________________________________________________
8 ____________________________________________________________________ M211429EN-E
- When an ESD workbench is not available, ground yourself to the
equipment chassis with a wrist strap and a resistive connection cord.
- If you are unable to take either of the above precautions, touch a
conductive part of the equipment chassis with your other hand before
touching ESD sensitive components.
- Always hold component boards by the edges and avoid touching the
component contacts.
Recycling
Recycle all applicable material.
Dispose of batteries and the unit according to statutory regulations. Do
not dispose of with regular household refuse.
Trademarks
DigiCORA is a registered trademark of Vaisala Oyj.
Windows is a registered trademark of Microsoft Corporation in the
United States and/or other countries.
License Agreement
This product contains software developed by Vaisala. Use of the software
is governed by license terms and conditions included in the applicable
supply contract or, in the absence of separate license terms and
conditions, by the General License Conditions of Vaisala Group.
This product may contain open source software (OSS) components. In
the event this product contains OSS components, then such OSS is
governed by the terms and conditions of the applicable OSS licenses, and
you are bound by the terms and conditions of such licenses in connection
with your use and distribution of the OSS in this product. Applicable
OSS licenses are included in the product itself or provided to you on any
other applicable media, depending on each individual product and the
product items delivered to you.
7/23/2019 radiosondaje vaisala
11/88
Chapter 1 _________________________________________________________ General Information
VAISALA _________________________________________________________________________ 9
Warranty
Visit our Internet pages for standard warranty terms and conditions:
http://www.vaisala.com/warranty.
Please observe that any such warranty may not be valid in case of
damage due to normal wear and tear, exceptional operating conditions,
negligent handling or installation, or unauthorized modifications. Please
see the applicable supply contract or Conditions of Sale for details of the
warranty for each product.
Technical Support
For technical questions, contact the Vaisala technical support by e-mail at
[email protected] at least the following supportinginformation:
- Name and model of the product in question
- Serial number of the product
- Name and location of the installation site
- Name and contact information of a technically competent person who
can provide further information on the problem.
Product Returns
If the product must be returned for service, seewww.vaisala.com/returns.
For contact information of Vaisala Service Centers, see
www.vaisala.com/servicecenters.
http://www.vaisala.com/warrantyhttp://www.vaisala.com/warrantymailto:[email protected]:[email protected]://www.vaisala.com/returnshttp://www.vaisala.com/returnshttp://www.vaisala.com/returnshttp://www.vaisala.com/servicecentershttp://www.vaisala.com/servicecentershttp://www.vaisala.com/servicecentershttp://www.vaisala.com/returnsmailto:[email protected]://www.vaisala.com/warranty7/23/2019 radiosondaje vaisala
12/88
Getting Started Guide ________________________________________________________________
10 ___________________________________________________________________ M211429EN-E
This page intentionally left blank.
7/23/2019 radiosondaje vaisala
13/88
Chapter 2 ___________________________________________________________ Product Overview
VAISALA ________________________________________________________________________ 11
CHAPTER 2
PRODUCT OVERVIEW
This chapter introduces the Vaisala DigiCORA Sounding System MW41
features.
Introduction to Vaisala DigiCORA Sounding
System MW41Vaisala MW41 sounding software is a radiosounding data processing,
analysis, archival and relaying software for DigiCORA Sounding System
MW41. The software consists of the user interface running on a web
browser and the sounding processing software running as services on a
PC computer.
DigiCORA Sounding System MW41 consists of a PC computer, which is
connected to a sounding processing subsystem via a network adapter.
Sounding Processing Subsystem SPS311 contains the processor units for
PTU (Pressure, Temperature and Humidity) and wind finding, andappropriate connections to the required antennas.
MW41 sounding software is used with Vaisala Radiosondes RS41 and
RS92, Sounding Processing Subsystem SPS311, Ground Check Devices
RI41 and RI41-B, and Ground Check Set GC25. RI41-B is equipped with
a barometer module.
Optionally, you can connect a printer to the sounding workstation for
printing sounding data.
Figure 1 on page 12 shows an overview of MW41 with RS41 and RI41.A more detailed MW41 system architecture picture is available in
Appendix A MW41 System Architecture on page83.
7/23/2019 radiosondaje vaisala
14/88
Getting Started Guide ________________________________________________________________
12 ___________________________________________________________________ M211429EN-E
1306-001
Figure 1 DigiCORA Sounding System MW41 Overview with
RS41
The following numbers refer toFigure 1 above:1 = Sounding Workstation PC
2 = Sounding Processing Subsystem SPS311
3 = Ground Check Device RI41 with RS41
4 = Radiosonde RS41
5 = GPS antenna
6 = UHF antenna
Figure 2 on page 13 shows an overview of MW41 with RS92 and GC25.
7/23/2019 radiosondaje vaisala
15/88
Chapter 2 ___________________________________________________________ Product Overview
VAISALA ________________________________________________________________________ 13
1308-039
Figure 2 DigiCORA Sounding System MW41 Overview with
RS92
The following numbers refer toFigure 2 above:1 = Sounding Workstation PC
2 = Sounding Processing Subsystem SPS311
3 = Ground Check Set GC25
4 = Radiosonde RS92
5 = GPS Antenna
6 = UHF Antenna
7/23/2019 radiosondaje vaisala
16/88
Getting Started Guide ________________________________________________________________
14 ___________________________________________________________________ M211429EN-E
Sounding Station Setup Summary
The summary contains everything you need to do when setting up an
entirely new MW41 system. In other cases, such as when upgrading from
an older system, some steps do not apply. For upgrade instructions, see
Upgrading MW11/12/15, MW21 and MW31 to Sounding System MW41
Technical Reference.
1. Select a suitable location for sounding.
SeeChapter 3, Selecting Location, on page 15 for more
information.
2. Install antennas as instructed in sectionAntennas on page 16.
3. Install Sounding Processing Subsystem SPS311 as instructed in
sectionMW41 Sounding Workstation Requirements on page 19.
4. Prepare the computer for MW41 installation as instructed in
sectionsOperating System Settings on page 25,andInstalling
Peripheral Devices on page 26.
Note that this has already been done on Vaisala-supplied
computers.
5. Install the MW41 software and activate the license on the
soundings workstation computer as instructed in sectionInstalling
MW41 Sounding System Software on page 27.
Note that Vaisala installs the software on Vaisala-supplied
computers at the factory.
6. Install a security certificate as instructed in sectionInstallingSecurity Certificate on page44.
Note that Vaisala installs the security certificate on Vaisala-
supplied computers at the factory.
7. Install RI41 for RS41 or GC25 for RS92 as instructed in section
Connecting Ground Check Device RI41 on page 59,or in section
Connecting Ground Check Set GC25 on page 60.
8. Complete the station-specific configurations as instructed in
Chapter 7, Starting the Sounding Software, on page 77.
7/23/2019 radiosondaje vaisala
17/88
Chapter 3 __________________________________________________________ Selecting Location
VAISALA ________________________________________________________________________ 15
CHAPTER 3
SELECTING LOCATION
This chapter contains information on how to find a suitable location for
MW41 Sounding System.
Sounding Operation Room
Besides providing good working conditions for the operator, thesounding operation room protects the ground equipment. Below are listed
the environmental conditions for the indoor equipment. In addition, direct
weather influences must be totally excluded. Refer to the corresponding
documentation for specifications on the required conditions for
individual system components.
See the manufacturer's notes for additional information:
Environmental Requirements for Indoor Equipment:Temperature +10 ... +35 C
Humidity 0 ... 90 % RH, non-condensing
Environmental Requirements for Outdoor Equipment:
Temperature -40 +55CHumidity 0 100% RH
In a tropical environment, it is recommended that you install an air
conditioner in the sounding operation room.
Equip the sounding operation room with the following:
- Adequate lighting
- Grounded electrical power outlets located close to the instrument
tables
- Desk for handling the radiosonde before release
At all sounding sites where a stable line voltage is not secured, it is
recommended to install and constantly use an uninterruptible power
supply (UPS) to guarantee successful soundings. See sectionUsing
Uninterruptible Power System (UPS, Optional) with MW41 on page 20
for more information.
7/23/2019 radiosondaje vaisala
18/88
Getting Started Guide ________________________________________________________________
16 ___________________________________________________________________ M211429EN-E
Antennas
For best results, select an installation site for the antenna set that is:
- Clear of obstacles such as buildings, dense forests, or metal masts.
- Even, in other words, the ground is even and relatively firm.
A single tree has no significant effect on signal reception, unless it is
very dense or less than 20 meters from the antenna set. Sparse forest can
cause some attenuation but is usually not a real hindrance.
1203-133
Figure 3 Signal Path Line-of-Sight Requirement
Other antenna masts and metal structures of small diameter do not disturb
reception if situated more than 20 meters away from the antenna set.
Metal roofs or other large surfaces may reflect signals, causing short-
duration fading. Large obstacles may block reception. To maintain the
line of sight, ensure that the angle from the antenna to the top of large
obstacles is less than 10. SeeFigure 3 above.
Antenna Types
The sounding instrument requires antennas for GPS and UHF reception.
The following antennas manufactured by Vaisala can be used:
- GA31, GA31N and GA41 GPS antenna
- RB31 directional UHF antenna
- RM31N and RM32 omnidirectional UHF antenna
- CG31 portable antenna
NOTE Antenna description and installation instructions are provided with eachantenna.
7/23/2019 radiosondaje vaisala
19/88
Chapter 3 __________________________________________________________ Selecting Location
VAISALA ________________________________________________________________________ 17
Antenna Cables
The standard length of the antenna cable is 33 meters. Lay the cables in
protective tubing to avoid mechanical wear. Secure the maximumpossible clearance from radar antennas. See the appropriate antenna
User's Guide for details.
Balloon-Filling Shed
An appropriate balloon-filling shed enabling proper inflation and
handling of the balloons is essential for a successful radiosonde ascent.
Observe the following recommendations when operating hydrogen
balloons:
- Place the shed near the sounding operation room so that the
radiosonde operator is able to view the shed from a window or the
door of the sounding operation room.
- Avoid inflating the balloon in the same building where the sounding
operation room is located because of the risks related to handling
gases.
- Free the terrain around the shed of obstacles such as trees, telephone
poles, antenna structures, etc., that might prevent free ascent of the
radiosonde in windy conditions.
- Make sure the balloon-filling shed:- is large enough to allow the operator to handle all normal types of
balloons conveniently.
- has a doorway wide enough for you to carry an inflated balloon
through without the balloon touching sharp corners or anything else
that can break it.
- has its door on the leeward side of prevailing winds.
- has free space for the gas generator or gas cylinders if there is no
separate chamber for them outside the shed.
- has adequate ventilation, especially when the doors are closed.
- Make sure all electrical installations within the shed, both permanent
and temporary, are of spark-proof construction. Carry out regular
inspections to prevent any oversights.
- Ground the inflation nozzle (Vaisala Filling Balance) through a metal
plate fixed to the floor. Connect the nozzle permanently to a well-
grounded piping system or some other construction with good earth
contact.
7/23/2019 radiosondaje vaisala
20/88
Getting Started Guide ________________________________________________________________
18 ___________________________________________________________________ M211429EN-E
- Note that since hydrogen mixed with air is highly inflammable, the
use and storage of hydrogen generators or cylinders are subject to
safety regulations issued by authorities.
- Follow the Safety Instructions for Radiosonde Operators given in the
Radiosonde User's Guide when training personnel for radiosondeoperation at a new station.
7/23/2019 radiosondaje vaisala
21/88
Chapter 4 __________________________________________________________ Installing Hardware
VAISALA ________________________________________________________________________ 19
CHAPTER 4
INSTALLING HARDWARE
This chapter provides information on the DigiCORA MW41 hardware
setup.
MW41 Sounding Workstation Requirements
Operating System Compliance
- Windows 7 Professional SP1 32-bit and 64-bit (English)
- Windows 8.1 Pro 32-bit and 64-bit (English)
Web Browser Compliance
- Microsoft Internet Explorer 9 or higher
- Mozilla Firefox (latest version)
- Google Chrome (latest version)Adobe Flash Player is required.
Minimum Hardware Requirements
- Processor Intel Pentium Dual Core or equivalent, Quad core
recommended
- Memory 2 GB RAM
- Hard Disk Space 160 GB
- Display 1366 x 768
- DVD-ROM drive
- Serial ports, either integrated or via USB/RS232 converter: 1 for
GC25/RS92 cable and 1 for possible Automatic Weather Station
(AWS)
- USB port for RI41
- Ethernet adapter
7/23/2019 radiosondaje vaisala
22/88
Getting Started Guide ________________________________________________________________
20 ___________________________________________________________________ M211429EN-E
For the operating system to function properly, make sure the following
settings have been selected and installed:
- The workstation has a network with TCP/IP Protocol installed.
- Time zone is GMT.
CAUTION When taking PCs not delivered by Vaisala into use, pay special attentionto energy saver and similar settings on your computer. On many
computers, the default settings can cause shutdown of computer parts if
there is a long time period with no input from the user, for example,
during a sounding. This might result in a lost sounding.
Using Uninterruptible Power System(UPS, Optional) with MW41
If the MW41 input power source, typically mains power, fails for some
reason, a UPS can be used to provide emergency power. The UPS
provides near-instantaneous protection from input power interruptions by
supplying energy to the connected devices.
To avoid any power interruptions, make sure that all sounding equipment
are connected through a UPS system. The sounding PC and the UPS are
connected with a USB cable. The correct USB connector is marked with
a UPS sticker at the back of the PC.
CAUTION Make sure to select the correct, country-specific output voltage on theUPS display. See the manufacturers instructions for more details.
The UPS includes internal batteries to provide power in case AC input
power is not available. Make sure to inspect the condition of the batteries
regularly and, if necessary, replace the batteries according to the
manufacturers instructions.
CAUTION Before taking the UPS into use, make sure the UPS internal batteries areconnected.
During a power interruption, the UPS provides power for 25 minutes,
after which Windows is run down. The rundown takes a maximum of 5
minutes. All other values are the default values provided by the UPS.
7/23/2019 radiosondaje vaisala
23/88
Chapter 4 __________________________________________________________ Installing Hardware
VAISALA ________________________________________________________________________ 21
Sounding Processing Subsystem SPS311
Sounding Processing Subsystem SPS311 is a desktop instrument
intended for use in the sounding operation room. You can fasten it to an
installation shelf with mounting straps.
- All power, signal and I/O connectors are located at the rear
- Plug-in units can be replaced through the front
SPS311 uses forced air cooling. Three fans are located below the card
frame.
NOTE Do not block the air inlet at the lower front corner of the chassis. Airoutlet is located at the upper rear corner.
Connecting Sounding ProcessingSubsystem SPS311
To connect antennas, MW41 workstation, and optional equipment to
SPS311, do the following:
1. Connect the antennas to the subsystem. Refer to the instructions in
the appropriate antenna Users Guide.
2. Connect the Sounding Processing Subsystem LAN1 connector via
the LAN switch (if connected to an external network) to the
workstations LAN card using the 210973 cable (Ethernet cable
with RJ45 connectors).
7/23/2019 radiosondaje vaisala
24/88
Getting Started Guide ________________________________________________________________
22 ___________________________________________________________________ M211429EN-E
1306-002
Figure 4 MW41 Connections
The following numbers refer toFigure 4 above:
1 = Sounding Processing Subsystem SPS311
2 = Sounding workstation PC
3 = GPS antenna
4 = UHF antenna
5 = LAN switch (optional)
6 = GPS cable (TNC connector)7 = UHF cable (N connector)
8 = Ethernet cable (RJ45 connector)
9 = Line to external network (optional)
10 = Ground Check Set GC25
11 = Ground Check Device RI41
12 = USB cable
13 = RS-232 cable
7/23/2019 radiosondaje vaisala
25/88
Chapter 4 __________________________________________________________ Installing Hardware
VAISALA ________________________________________________________________________ 23
3. Connect the ethernet cable to the computers ethernet port.
4. Either Ground Check Device RI41 for RS41, or Ground Check Set
GC25 for RS92 is connected to the sounding workstation PC.
If the system has a direct cable connection to an RS92 radiosonde,
connect the radiosonde cable (DRW231463) to the workstation's
COM port. Connect the AC/DC adapter to the radiosonde cable's
DC connector.
Power Supply and Grounding for SPS311
SPS311 must be connected to mains power 100 - 240 V, 1.2A Max,
50/60 Hz or to a 24 VDC power system. The DC power input connection
is floating.
An external chassis ground screw is provided for system grounding.
NOTE Mains power and 24 VDC system power are alternative power sourcesand need not be used at the same time.
Switching the Power On and Off
The power switch of SPS311 is located on the lower left corner of the
front panel. The power switch is marked with the following symbol:
Before the subsystem power can be switched on, the system must be in
the standby state. This is indicated by the yellow standby LED. For more
information on the indicator LEDs, see Vaisala DigiCORA Sounding
System MW41 Technical Reference.
To switch subsystem power on or off, press the power switch once.
The standby LED is lit yellow when the system is ready for powerup.
After the power is switched on, the standby LED is blank.
During the power up the power/status LED blinks green. When the
power/status LED turns into steady green the system is ready for
operation.
Red color indicates an error in one or more units during the power up or
operation.
7/23/2019 radiosondaje vaisala
26/88
Getting Started Guide ________________________________________________________________
24 ___________________________________________________________________ M211429EN-E
This page intentionally left blank.
7/23/2019 radiosondaje vaisala
27/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 25
CHAPTER 5
INSTALLING SOFTWARE
This chapter provides information on how to install the required software
for Sounding System MW41.
NOTE If Vaisala has provided the computer for your Sounding System MW41,the software installation has been done by Vaisala. In this case, you may
skip this chapter and move on toChapter 6, Creating Connections, onpage 51.
Operating System Settings
For the operating system to function properly, make sure the following
settings have been selected and installed:
- The workstation has a network with TCP/IP Protocol installed.
- Time zone is GMT.
User Requirements for Installing theSoftware
To perform the needed installations, you need administrator rights for
Windows. Vaisala recommends that after the sounding software has been
installed, you access the sounding workstation PC with operator-level
privileges (not administrator).
NOTE When you install the MW41 sounding software, you must belong to theAdministratorslevel. See your operating system documentation for
more information.
NOTE On computers delivered from Vaisala, you need to give a password to logon to the PC as Administrator. The Administrator password is
adpw_VA1.
7/23/2019 radiosondaje vaisala
28/88
Getting Started Guide ________________________________________________________________
26 ___________________________________________________________________ M211429EN-E
Dividing Workstation's Hard Disk
Note that it is not absolutely necessary to divide the workstation's hard
disk into two partitions. However, by default, the sounding file and
message output folders are placed on the D: partition, if available.Having the archives separate from the system partition can make the files
easier to backup, for example, to a DVD-ROM.
On computers delivered by Vaisala the partitions are done as described
below, and this can be used as a recommendation for partitioning other
sounding workstations, if desired. Follow the Windows operating
system's instructions, and the instructions below.
- Make the C: partition 100 GB in size. This is the default installation
location for the MW41 sounding software. The path can also be
changed.
- Make the D: partition to contain the rest of the hard disk. Format this
partition to use the NTFS file system. This way you can use the
Windows backup feature to secure the content of the hard disk.
Installing Peripheral Devices
Serial Port Extension
It is likely that a serial port extension device is needed to meet the
requirements stated in sectionMW41 Sounding Workstation
Requirements on page 19.For computers not delivered by Vaisala, this is
your responsibility. Refer to the instructions supplied with the device.
Printer
If your MW41 sounding system includes a printer, set it up to work with
Windows. Refer to the instructions supplied with Windows and the
printer.
For instructions on adding a new printer, see DigiCORA SoundingSystem MW41 Technical Reference.
7/23/2019 radiosondaje vaisala
29/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 27
Installing MW41 Sounding System Software
These instructions provide information on installing MW41 sounding
software for the first time. For updating instructions, see Vaisala
DigiCORA Sounding System MW41 Technical Reference.
NOTE Before installing the software, check the MW41 workstationrequirements in sectionMW41 Sounding Workstation Requirements on
page 19.
Note that if some components needed for installing MW41 sounding
software, for example Flash Player, are missing, the Installer prompts
you to install them first and restart your computer.
The software installation consists of three phases, explained in the
sections below:
1. Installing MW41 sounding software.
2. Activating a software license.
3. Installing a security certificate.
Requirements for Installing MW41 in
Windows 8.1 Operating SystemSounding software MW41 requires .NET Framework 3.5, which is not
included in Windows 8.1 by default. Before installing MW41, you must
install the .NET Framework 3.5. There are two ways of doing this,
depending on whether you are connected to Internet or not. See sections
Internet Connection Available below andNo Internet Connection
Available on page 28 for instructions.
Internet Connection Available
If you are connected to Internet while you are installing MW41, awindow for downloading and installing .NET Framework 3.5 will appear
automatically when you click the MW41 StartHere.exefile.
Click Download and install this featureto begin the installation, see
Figure 5 on page 28.
NOTE Depending on the connection, the download takes some time, from 5 to15 minutes.
7/23/2019 radiosondaje vaisala
30/88
Getting Started Guide ________________________________________________________________
28 ___________________________________________________________________ M211429EN-E
1312-001
Figure 5 Downloading and Installing .NET Framework 3.5
No Internet Connection Available
If you are not connected to Internet during MW41 installation, you must
install the .NET Framework 3.5 manually. Before beginning, insert the
Windows 8.1 installation DVD to the PC.
Follow the instructions below:
1. Open Windows Command Prompt as Administrator: right-click
and select Run as administrator.
2. Give the Windows administrators user name.
3. Enter the following command. The source in this case is the
Windows 8.1 installation DVD on the DVD drive.
DISM /Online /Enable-Feature /FeatureName:NetFx3 /All /LimitAccess
/Source:d:\sources\sxs
4. The .NET Framework 3.5 installation begins.
5. After the .NET Framework installation, install the MW41 sounding
software as instructed in the next sectionBeginning MW41
Software Installation on page 29.
For further information, see the instructions on Microsofts web page:
http://msdn.microsoft.com/en-us/library/hh506443.aspx
http://msdn.microsoft.com/en-us/library/hh506443.aspxhttp://msdn.microsoft.com/en-us/library/hh506443.aspxhttp://msdn.microsoft.com/en-us/library/hh506443.aspx7/23/2019 radiosondaje vaisala
31/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 29
Beginning MW41 Software Installation
Installing Flash Player to Windows 8.1
Operating System
In Windows 8.1, Adobe Flash Player is built-in in Internet Explorer and
cannot be updated by an external software such as the MW41 installer.
To run MW41, you must update Adobe Flash Player to the latest version
available via Windows update.
Installing Flash Player to OtherOperating Systems
NOTE If your computer is connected to the Internet while you are installing thesoftware and you are prompted to install a newer version of Flash Player
by clicking the Player Download Center link, do notclick the link.
Instead, install the latest version available on the DVD. This is to make
sure that the MW41 sounding software functions properly.
If you get the following error message when beginning MW41
installation, follow the steps below to install Flash Player. These
instructions do not apply to Windows 8.1, where the update must be done
via Windows update.
1211-032
Figure 6 Adobe Flash Player Installation Error Message
1. Do not click the link that appears in the error message shown in
Figure 6 above.Click Quitto close the window.
7/23/2019 radiosondaje vaisala
32/88
Getting Started Guide ________________________________________________________________
30 ___________________________________________________________________ M211429EN-E
2. Go to folder MW41 - 3rdPartySoftware - FlashPlayeron the
installation DVD.
3. Click the uninstall_flash_player.exefile to uninstall Flash Player.
4. After Flash Player has been uninstalled, restart MW41 installation.
5. Click the Install Flash Player for Internet Explorerlink.
Software License
Using MW41 sounding software requires a software license. When you
install the software for the first time, you have two options for using it,
explained in more detail in this section.
1. Using a Trial Version
If you have no software license, you can start using the software as a trialversion with standard features. The trial version is valid for 30 days.
After you have installed the sounding software and login for the first
time, the system detects whether you have a valid license or not, or
whether the trial version has expired. If your trial version has not expired,
you can continue to use it for the number of trial days remaining.
2. Activating Software License
If you have a software license, you can immediately activate the softwarewith the features you have selected after you have installed the software.
Activate the license using the Product Key available on a sticker on the
sounding software DVD cover. It is recommended to activate the license
as soon as possible.
NOTE Vaisala recommends that you activate the software license as soon aspossible.
Activating the MW41 software license requires Internet connection. If
the PC you are using for the software installation does not have Internetconnection, make sure there is another PC nearby with an Internet
connection that you can use for the activation. Vaisala License Manager
automatically detects whether you are connected to Internet or not.
For instructions, see either sectionActivating the License - Internet
Connection Available on page 35,or sectionActivating the License - No
Internet Connection Available on page 37.
7/23/2019 radiosondaje vaisala
33/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 31
Installing MW41 Sounding Software andActivating Software License
To install the MW41 sounding software:
1. Place the installation DVD into the DVD drive. The installation
main window opens. If the installer does not start automatically,
run the StartHere.exefile from the DVD.
2. Click the link Install MW41 version X.X.x
1209-017
3. The Install Wizard for MW41 opens. Click Next.
7/23/2019 radiosondaje vaisala
34/88
Getting Started Guide ________________________________________________________________
32 ___________________________________________________________________ M211429EN-E
4. Read the License Agreement and accept it. Click Next.
5. The installation begins. Click Nextto accept the default destination
folder for the files, or choose a new folder by clicking Changeand
select a new location for the files.
7/23/2019 radiosondaje vaisala
35/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 33
6. Click Installto begin the installation.
7. Wait while the Install Wizard installs the software.
7/23/2019 radiosondaje vaisala
36/88
Getting Started Guide ________________________________________________________________
34 ___________________________________________________________________ M211429EN-E
8. When the software installation is finished, the following window
opens. Option Launch Vaisala License Manageris selected by
default.
9. Click Finishto start Vaisala License Manager and proceed to the
instructions in sectionActivating the License - Internet Connection
Available on page 35,or sectionActivating the License - No
Internet Connection Available on page 37.
NOTE Vaisala recommends that you activate the software license as soon aspossible. Activating the license requires access to Internet.
If you deselect the default option, you are prompted to restart the
system. After the restart, the software installation is ready. See
sectionLaunching Vaisala License Manager below for instructions
on launching Vaisala License Manager at a later stage.
Launching Vaisala License Manager
To activate the software license at a later stage, you must launch Vaisala
License Manager:
Go to Windows Start menu and click All Programs - Vaisala Vaisala
License Manager Vaisala License Manager. The License Manager is
installed on your computer when MW41 sounding software is installed.
Next, proceed to sectionActivating the License - Internet Connection
Available on page 35,or sectionActivating the License - No Internet
Connection Available on page 37.
7/23/2019 radiosondaje vaisala
37/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 35
Activating the License - Internet ConnectionAvailable
1. When the License Manager opens, click Continue.
1305-061
Figure 7 Activating Product
2. Enter the Product Key. The Product Key is available on a sticker on
the DVD cover. Click Continue.
1305-062
Figure 8 Entering Product Key
3. The product starts activating. Wait a while.
7/23/2019 radiosondaje vaisala
38/88
Getting Started Guide ________________________________________________________________
36 ___________________________________________________________________ M211429EN-E
4. After a successful activation, the following window is displayed.
The window displays a list of the activated features. Check that the
features installed match your license. Click Quitto exit License
Manager.
1306-153
Figure 9 List of Activated Features
5. Click Yes to restart the system.
1209-019
6. After the system has restarted, the MW41 installation and license
activation is complete.
In case the activation fails, the reason and remedy for the failure are
displayed. Should you need any further assistance, contact Vaisala Help
Desk [email protected].
mailto:[email protected]:[email protected]:[email protected]:[email protected]7/23/2019 radiosondaje vaisala
39/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 37
Activating the License - No Internet ConnectionAvailable
Before you begin, make sure that you have, for example, a memory stick
for storing the license file obtained and transferring it to anothercomputer.
1. When the License Manager opens, click Continue.
1305-061
Figure 10 Activating Product
2. Enter the Product Key. The Product Key is available on a sticker on
the DVD cover. Click Continue.
1305-062
Figure 11 Entering Product Key
7/23/2019 radiosondaje vaisala
40/88
Getting Started Guide ________________________________________________________________
38 ___________________________________________________________________ M211429EN-E
3. The following window opens with message You have no Internet
connection available. Write down the Product Key and the request
code shown, or click Save codes as txtto save the codes as a .txt
file on a media that you can take with you, for example, a memory
stick. Remember also to write down the Internet address you mustgo to.
Do not close the License Manager window, you will need to upload
the license file with License Manager.
1305-065
Figure 12 No Internet Connection is Available
4. Take the memory stick with you and go to another computer that isconnected to Internet, and log on to the address provided. Select
Login Using Product Keyand enter the key in the window. Click
Login.
1305-066
Figure 13 License Manager Login Window
7/23/2019 radiosondaje vaisala
41/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 39
5. In the window that opens, click Product Detailsopen and click
Activate.
1305-068
Figure 14 Viewing Product Details
6. Enter the request code in the Request Codetext box and click
Generate.
1605-069
Figure 15 Generating License File
7/23/2019 radiosondaje vaisala
42/88
Getting Started Guide ________________________________________________________________
40 ___________________________________________________________________ M211429EN-E
7. The license file is generated. Save the license file to a media that
you can transfer to the system with MW41 sounding software, for
example, a memory stick.
1305-070
Figure 16 License File Successfully Generated
Note that the way in which the file is saved depends on the browser used.
For example, in Internet Explorer, a dialogue appears, asking you about
the file. If you do not provide a specific location on your computer, files
downloaded from the Internet are usually saved in a default location, for
example, C:\users\your name\downloads.
7/23/2019 radiosondaje vaisala
43/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 41
8. Take the memory stick with you and go back to the computer
where the License Manager window is still open, and MW41
software is installed with no Internet connection. Click Uploadto
load the license file to the system.
Figure 17 Uploading License File
9. Browse to the location where the license file is stored and click
Open.
1305-072
Figure 18 Opening License File
7/23/2019 radiosondaje vaisala
44/88
Getting Started Guide ________________________________________________________________
42 ___________________________________________________________________ M211429EN-E
10. The green icon indicates that the upload was successful. Click
Continue.
1305-073
Figure 19 License File Successfully Uploaded
11. After a successful activation, the following window is displayed.
The window displays a list of the activated features. Check that the
features installed match your license. Click Quitto exit License
Manager.
1305-074
Figure 20 Displaying Installed Features
7/23/2019 radiosondaje vaisala
45/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 43
12. Click Yes to restart the system.
1209-019
13. After the system has restarted, the MW41 installation and license
activation is complete.
In case the activation fails, the reason and remedy for the failure aredisplayed. Should you need any further assistance, contact Vaisala Help
Desk [email protected].
mailto:[email protected]:[email protected]:[email protected]:[email protected]7/23/2019 radiosondaje vaisala
46/88
Getting Started Guide ________________________________________________________________
44 ___________________________________________________________________ M211429EN-E
Installing Security Certificate
MW41 sounding software uses a security certificate to support HTTPS
protocol in the web browser interface.
NOTE The security certificate is installed after the MW41 sounding software isinstalled for the first time, it is not required after software update.
Note that the security certificate is Windows user-specific, that is, it has
to be installed separately for all Windows users. On Vaisala-delivered
PCs, the security certificate is installed for the default Windows users.
When creating new users, the security certificate needs to be installed
separately for the new users. To install the security certificate, follow the
steps below.
NOTE Note that if you change the MW41 computer name, you must alwaysinstall the security certificate.
Some of the windows presented below differ between 32-bit and 64-bit
operating systems, but the installation steps are the same.
Adding MW41 Address to Trusted SitesWhen installing the security certificate on a computer with Windows 8.1
operating system and Internet Explorer version 10, you must first add
MW41s address to Internet Explorers trusted sites. Otherwise you will
not be able to install the security certificate.
- To find out the MW41 address, go to Control Panel, select System
and Security System Full computer name.
- To add the MW41 address to trusted sites, go to Internet Explorer,
select Tools Internet Options- Security - Trusted sites. Click
Sites, Add, and enter the MW41 address.
Installation Steps
1. Click the icon on the desktop to start MW41 sounding software:
1205-136
7/23/2019 radiosondaje vaisala
47/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 45
2. The Security Alert window appears. Click View Certificate.
1205-107
3. The Certificate window appears. Click Install Certificate.
1205-108
7/23/2019 radiosondaje vaisala
48/88
Getting Started Guide ________________________________________________________________
46 ___________________________________________________________________ M211429EN-E
4. Certificate Import Wizard opens. Click Next.
1205-109
5. Select the Place all certificates in the following storeoption and
click Browse.
1205-110
7/23/2019 radiosondaje vaisala
49/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 47
6. Select Trusted Root Certification Authoritiesand click OK.
1205-111
7. The Certificate Import Wizard window opens again. Click Next.
1205-112
7/23/2019 radiosondaje vaisala
50/88
Getting Started Guide ________________________________________________________________
48 ___________________________________________________________________ M211429EN-E
8. Click Finish.
1205-113
9. In the Security Warning window, click Yes.
1205-114
7/23/2019 radiosondaje vaisala
51/88
Chapter 5 __________________________________________________________ Installing Software
VAISALA ________________________________________________________________________ 49
10. Click OK. The certificate has now been successfully imported.
1205-115
11. Click OKto accept the installed certificate.
1205-116
7/23/2019 radiosondaje vaisala
52/88
Getting Started Guide ________________________________________________________________
50 ___________________________________________________________________ M211429EN-E
12. In the Security Alert window, click Yes.
1205-117
13. The security certificate is now installed on the sounding
workstation and MW41 sounding software uses a safe HTTPS
connection.
7/23/2019 radiosondaje vaisala
53/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 51
CHAPTER 6
CREATING CONNECTIONS
This chapter contains instructions on how to connect the MW41
Sounding System components.
Connecting SPS311
To connect the MW41 computer to Sounding Processing SubsystemSPS311, create the following firewall and SPS311 IP address settings:
1. Make all the physical connections as instructed in section
Connecting Sounding Processing Subsystem SPS311 on page 21.
2. Check that a firewall does not hinder the connections. See section
Using Firewall on page 52.
3. To change the IP addresses, see sectionChanging SPS311 IP
Address on page 52.
NOTE SPS311s default IP address is 192.168.0.10.
The workstation's default IP address is 192.168.0.1.
7/23/2019 radiosondaje vaisala
54/88
Getting Started Guide ________________________________________________________________
52 ___________________________________________________________________ M211429EN-E
Using Firewall
NOTE It is recommended to use a firewall between the MW41 workstation and
the sounding subsystem.
Windows Firewall
You do not have to disable the Windows firewall to be able to create
MW41 connections. MW41 installer automatically opens the necessary
ports.
Other Firewalls
Other firewalls require you to open the following ports manually:
- Inbound port 42990 for SPS311
- Outbound port 42900 for SPS311
Changing SPS311 IP Address
After you have created the connection to the unit, you can configure
Sounding Processing Subsystem SPS311 unit using the RegConfig
program.
RegConfig is an internal program in SPS311 plug-in units for setting the
communication parameters of the unit.
Connecting to SPS311
There are two ways of connecting to SPS311: VNC and PuTTY. The
primary method is VNC, but, if that fails, you can use PuTTY.
Connecting with VNC
To create a connection to a plug-in unit with VNC:
1. Switch on the power to the sounding processing subsystem.
2. Start VNCViewer by selecting Start - Run and type
[MW41 Install Directory]\Utils\VNCViewer\VNCViewer.exe.
(The default MW41 install directory in 64-bit Windows 7 is
C:\Program Files (x86)\Vaisala\MW41\).
7/23/2019 radiosondaje vaisala
55/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 53
3. Enter the units default IP address in the VNC server box and click
OK.
- SPS311: 192.168.0.10
4. Login to the system by entering the following information:
- Session password: Administrator
5. ClickOK.
6. Start the RegConfig program on the unit by clicking the Start
button and selecting Run.
7. Type regconfigin the Opentext box and click OK.For information on using the RegConfig program, see section
Using RegConfig to Change the SPS311 IP Address on page 58.
8. If you have made changes with RegConfig, you are prompted to
save the changes. If you choose to save your changes, the unit
restarts automatically and the VNC connection ends.
9. If you did not make any changes, end the connection by clicking
Close.
Connecting with PuTTY
To create a connection to a plug-in unit with PuTTY:
1. Open the SPS311 front cover to access the MRP111 units COM1
port.
2. Connect the workstation's COM port to the MRP111 unit's COM1
port with cable MW45042.3. Start the program by selecting Start Runand type
[MW41 Install Directory]\Utils\Putty\PuTTY.exe
(The default MW41 install directory in 64-bit Windows 7 is
C:\Program Files (x86)\Vaisala\MW41\).
7/23/2019 radiosondaje vaisala
56/88
Getting Started Guide ________________________________________________________________
54 ___________________________________________________________________ M211429EN-E
4. Click Connection - Serialon the left, and set the properties of the
new connection on the right. See the next step for details.
1206-005
7/23/2019 radiosondaje vaisala
57/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 55
5. In the Serial linefield, enter the workstations COM port to which
the cable is connected. In the Speedfield, enter the baud rate.
1206-006
7/23/2019 radiosondaje vaisala
58/88
Getting Started Guide ________________________________________________________________
56 ___________________________________________________________________ M211429EN-E
6. Configure the settings:
Speed (baud):19200
Data bits:8
Stop bits:1Parity:None
Flow Control:None
1206-007
7. Click Open. The terminal opens.
7/23/2019 radiosondaje vaisala
59/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 57
8. The system prompts you for:
UserName: Administrator (ENTER)
Domain: (empty) (ENTER)
Password: Administrator (ENTER)
1206-008
9. Start the RegConfig program by entering regconfigand pressENTER. For information on using the RegConfig program, see
sectionUsing RegConfig to Change the SPS311 IP Address on
page 58.
10. If you have made changes with RegConfig, you are prompted tosave the changes. If you choose to save your changes, the unit
restarts automatically and the PuTTY connection ends.
11. If you did not make any changes, end the connection in the
following way:
- SPS311: Type exitand press ENTER.
- Close the program.
7/23/2019 radiosondaje vaisala
60/88
Getting Started Guide ________________________________________________________________
58 ___________________________________________________________________ M211429EN-E
Using RegConfig to Change the SPS311IP Address
Table 3 below lists the required settings when using RegConfig:
Table 3 SPS311 Parameter Settings
Hostname/Computer name
= MRP111- unit's hostname
IPAddress = 192.168.0.10 unit's IP address
SubnetMask = 255.255.255.0 unit's subnet mask
DefaultGateway = 0.0.0.0 unit's default gateway
VaisalaNameServer = MMWCannot be edited, for viewingonly.
NOTE VaisalaNameServer cannot be edited, the information can only beviewed.
RegConfig also displays hardware information: the serial number of the
plug-in unit and the hardware version.
7/23/2019 radiosondaje vaisala
61/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 59
Changing the Administrator Password on SPS311
Plug-in unit MRP111 has a user name "administrator", whose default
password is "Administrator". To change the password:
1. Open a connection to the unit. For details, see sectionUsing
RegConfig to Change the SPS311 IP Address on page 58.
2. Start User Managerby selecting Start - Run. Type cmdto open a
Command Prompt and then type usermgr.cmd
3. Double-click Administrator in the Username list.
4. Type the new password to Password and Confirm Password
boxes.
NOTE Do not change other options for this user. Memorize the new password
carefully.
5. Close User Managerby selecting User - Exit. The unit will now
restart. Starting the unit takes about two minutes.
Connecting Ground Check Device RI41
If you have used GC25 for preparing the radiosonde in the previous
soundings, you must disable it before taking Ground Check Device RI41
into use. Follow the steps below to disable GC25.
If you have not used GC25, start from step 4 below.
1. In MW41, select Administration Devices, and click open
Radiosonde workstation connection.
2. Click the drop-down list open and select None. Click Save.
3. Switch off GC25 and disconnect the cable from the sounding
workstation PC. Disconnect GC25 power cable.
4. Connect RI41 USB cable to the PCs USB port. The USB cable is
permanently attached to the ground check device. The ground
check device is powered on when it is connected to the PC.5. Next, configure RI41 as the ground check device to be used as the
connection between the radiosonde and the sounding workstation.
To do this, go to MW41 sounding software and select
Administration Devices, and click open Radiosonde
workstation connection. Select the correct device in the drop-
down list. Select also the correct serial port. Click Save.
7/23/2019 radiosondaje vaisala
62/88
Getting Started Guide ________________________________________________________________
60 ___________________________________________________________________ M211429EN-E
Ground Check Set GC25
Connecting Ground Check Set GC25
When setting up Ground Check Set GC25, connect the GC25 power
supply connector to the power socket. Then connect the power supply
cable.
To use GC25 with the MW41 system, connect the RS-232 cable to the
slanted serial connector (on the back of the GC25) and to the PC's serial
port. Secure the cable with screws. The RS-232 cable is delivered with
GC25.
Press the power switch. GC25 is ready for use when the display shows
the message "Connect Cable to Sonde".
Filling the Desiccant
When you first install GC25, follow theFilling the GC25 Chamber with
Desiccant instructionson page 61 carefully.
NOTE Since the desiccant beads need to be dried, it is convenient to use severaldesiccant cartridges in rotation with GC25. This eliminates the need to
open and refill the cartridge with dry desiccant beads. Extra cartridges
can be ordered from Vaisala.
7/23/2019 radiosondaje vaisala
63/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 61
Filling the GC25 Chamber with Desiccant
During first installation:
1. Pull out the desiccant cartridge from the side of the chamber. Refer
toFigure 21 below.
1201-021
Figure 21 Taking Out the Desiccant Cartridge
7/23/2019 radiosondaje vaisala
64/88
Getting Started Guide ________________________________________________________________
62 ___________________________________________________________________ M211429EN-E
2. Hold the base firmly and open the top of the desiccant cartridge.
Loosen the screws to release the metal top. SeeFigure 22 below.
1201-020
Figure 22 Opening the Desiccant Cartridge
NOTE Be careful not to deform or damage the metal netting. Always hold thecartridge by the metal base.
7/23/2019 radiosondaje vaisala
65/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 63
3. Fill the metal net enclosure with desiccant beads. SeeFigure 23
below.
1201-017
Figure 23 Filling the Desiccant Cartridge
4. Replace the metal top of the desiccant cartridge.
5. Tighten the screws to secure the metal top.
6. Put the desiccant cartridge back in the side of the chamber.
NOTE Make sure the chamber cover of GC25 is closed properly.
7/23/2019 radiosondaje vaisala
66/88
Getting Started Guide ________________________________________________________________
64 ___________________________________________________________________ M211429EN-E
Creating Remote Connection
To connect remotely to an MW41 workstation, you must create a trusted
HTTPS connection. See the instructions in sectionCreating Trusted
HTTPS Connection below.
By default, the security certificate is a self-signed HTTPS certificate. For
instructions on changing the default certificate to that of a Certificate
Authority, see DigiCORA Sounding System MW41 Technical
Reference.
Creating Trusted HTTPS Connection
These instructions are for remote client use, that is, when you create a
remote connection to the sounding workstation from another PC.
Note that the procedure is slightly different for different browsers.
NOTE Remote access HTTPS connection to the MW41 computer requiresinbound port 8443 to be open in all firewalls active in the system.
Creating Trusted HTTPS Connection with InternetExplorer
After you have installed the security certificate, you can create a remote
connection to the sounding workstation using https.
1. Go to addresshttps://computer.full.name:8443
NOTE Use the computer name, not the IP address.
To find out the name of your computer, check the information in the
System Propertieswindow. You can access the window, for example,
by pressing the Windows and Pause key simultaneously.
https://computer.full.name:8443/https://computer.full.name:8443/https://computer.full.name:8443/https://computer.full.name:8443/7/23/2019 radiosondaje vaisala
67/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 65
2. Click Continue to this website (not recommended).
1205-119
3. The MW41 login window opens with a "Certificate error" error
message in the browser's address bar. Click the error message and
select View certificates at the bottom.
1205-120
4. To proceed with the installation, follow steps 3 - 13 in section
Installing Security Certificate starting on page44.
5. Restart Internet Explorer and go tohttps://computer.full.name:8443
Creating Trusted HTTPS Connection with Firefox
If you have already installed the certificate for Internet Explorer, as
instructed above in sectionCreating Trusted HTTPS Connection with
Internet Explorer,you only have to click Confirm Security Exceptionin
step 4 below, and the HTTPS works for Firefox.
If you have not yet installed the certificate for Internet Explorer, start
from step 1 in the following step list.
https://computer.full.name:8443/https://computer.full.name:8443/https://computer.full.name:8443/https://computer.full.name:8443/7/23/2019 radiosondaje vaisala
68/88
Getting Started Guide ________________________________________________________________
66 ___________________________________________________________________ M211429EN-E
1. Go to addresshttps://computer.full.name:8443
2. Click I Understand the Risks.
1205-121
3. Click the Add Exceptionbutton.
1205-122
https://computer.full.name:8443/https://computer.full.name:8443/https://computer.full.name:8443/https://computer.full.name:8443/7/23/2019 radiosondaje vaisala
69/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 67
4. First click the Get Certificatebutton,then click the Viewbutton.
1205-123
5. Select the Detailstab and click Export.
1205-124
7/23/2019 radiosondaje vaisala
70/88
Getting Started Guide ________________________________________________________________
68 ___________________________________________________________________ M211429EN-E
6. Select a directory where you wish to save the certificate and click
Save.
NOTE The certificate file name is the same as the MW41 computer name. Do
not change the name.
1205-125
7. Click Close.
8. The saved certificate must be added as Windowss Trust Root
Certificate. Go to Control Panel and select Internet Options on the
left.
1205-138
7/23/2019 radiosondaje vaisala
71/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 69
9. Select the Contenttab and click Certificates.
1205-139
7/23/2019 radiosondaje vaisala
72/88
Getting Started Guide ________________________________________________________________
70 ___________________________________________________________________ M211429EN-E
10. Select the Trusted Root Certification Authoritiestab and click
Import.
1205-140
11. The Certificate Import Wizard window opens. Click Next.
1205-141
7/23/2019 radiosondaje vaisala
73/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 71
12. Click Browseand select the certificate file you saved in step 6
above. Click Openand Next.
1205-142
13. Select Place all certificates in the following storeand click
Browse.
1205-143
7/23/2019 radiosondaje vaisala
74/88
Getting Started Guide ________________________________________________________________
72 ___________________________________________________________________ M211429EN-E
14. Select Trusted Root Certification Authoritiesand click OK.
1205-144
15. Click Next.
1205-145
7/23/2019 radiosondaje vaisala
75/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 73
16. Click Finish.
1205-146
17. The Security Warning window opens. Click Yes.
1205-147
7/23/2019 radiosondaje vaisala
76/88
Getting Started Guide ________________________________________________________________
74 ___________________________________________________________________ M211429EN-E
18. Click OK.
1205-148
19. In the Certificates window, click Close, and in the Internet
Properties window, click OK.
1205-149
7/23/2019 radiosondaje vaisala
77/88
Chapter 6 ________________________________________________________ Creating Connections
VAISALA ________________________________________________________________________ 75
20. Go back to Firefox and click Confirm Security Exception.
1205-150
7/23/2019 radiosondaje vaisala
78/88
Getting Started Guide ________________________________________________________________
76 ___________________________________________________________________ M211429EN-E
Creating Trusted HTTPS Connection with GoogleChrome
If you use Google Chrome as your web browser, you must install the
security certificate using Internet Explorer, see sectionCreating Trusted
HTTPS Connection with Internet Explorer on page64 for instructions.
The security certificate cannot be installed with Chrome.
After you have installed the certificate with Internet Explorer and start
using Chrome, Chrome will also start using a safe HTTPS connection.
Note that in Chrome, https:is crossed out with a red line and a red cross
appears on the lock icon in the browser's address bar, seeFigure 24 on
page76 for an illustration. However, you do not have to worry about this:
Chrome still uses the security certificate in the same way as the other
browsers.
If are using a certificate signed by Certificate Authority and not the
default certificate, the markings will not appear in the address bar.
1210-074
Figure 24 Using Security Certificate with Google Chrome
7/23/2019 radiosondaje vaisala
79/88
Chapter 7 ________________________________________________ Starting the Sounding Software
VAISALA ________________________________________________________________________ 77
CHAPTER 7
STARTING THE SOUNDINGSOFTWARE
This chapter provides information on what to do after you have
completed the mechanical and software installations for Sounding
System MW41.
Starting the MW41 Software and Logging In
1. Power on Sounding Processing Subsystem SPS311 before turning
on the PC with the sounding software.
2. Turn on the PC.
3. To start the MW41 sounding software, either click the MW41icon
on the desktop, or enter the address
https://full.computer.name:8443in the address bar of your web
browser. (To see the full name of your computer, you can, for
example, press the Windows key and Pause key simultaneously toview the computer properties.)
https://full.computer.name:8443/https://full.computer.name:8443/https://full.computer.name:8443/7/23/2019 radiosondaje vaisala
80/88
Getting Started Guide ________________________________________________________________
78 ___________________________________________________________________ M211429EN-E
4. To make all the necessary configurations, login with your Sounding
administrator username and password. See sectionManaging
MW41 Users on page 79 for more information about users and user
roles.
1311-254
If the Read-onlycheck box is selected, you have read-only rights
to the system, not full control. The check box is selected if another
user already has full control of the system when you log in.
See section Managing MW41 Userson page 79 for more
information on user control in MW41 user interface.
5. All MW41 services start automatically and a message is displayed
to indicate that the system is starting.
7/23/2019 radiosondaje vaisala
81/88
Chapter 7 ________________________________________________ Starting the Sounding Software
VAISALA ________________________________________________________________________ 79
Managing MW41 Users
In MW41, the users are categorized into three groups with different
privileges.Table 4 below describes the different user roles.
CAUTION Make sure there is a Sounding administration user with a knownpassword at all times. Without this, you are unable to do user
management and other system configuration tasks, and may need to
reinstall the MW41 software.
Ta