4
MODEL SELECTION TABLE: Model 2G Maximum Pressure PSI (BAR) Minimum Gas Inlet Pressure PSI (BAR) Maximum Discharge Flow Rate @ 70-CPM SCFM (LPM) Inlet Outlet TWO STAGE 0714 510 (35) 1,700 (117) 30 (2) 7.02 (199) 0730 220 (15) 4,500 (310) 30 (2) 3.12(88) 0750 115 (8) 7,500 (517) 30 (2) 1.7 (48) 1430 820 (57) 4,100 (283) 80 (6) 5.89 (167) 1450 450 (31) 7,500 (517) 80 (6) 3.25 (92) 1492 250 (17) 14,500 (1,000) 80 (6) 1.18 (33) 3050 2,200 (152) 7,200 (497) 300 (21) 6.93 (196) 3092 1,300 (90) 14,000 (966) 300 (21) 4.04 (114) 5092 4,200 (290) 12,500 (862) 500 (34) 7.36 (208) DOUBLE ACTING 0707 800 (55) 800 (55) 30 (2) 21.9 (620) 1414 1,500 (103) 1,500 (103) 80 (6) 21.54 (610) 3030 3,500 (241) 3,500 (241) 300 (21) 22.22 (629) 5050 6,000 (414) 6,000 (414) 500 (34) 21.39 (606) 9292 6,000 (414) 13,000 (897) 800 (55) 12 (340) CONTROLS: Automatic High Pressure Limit Switch set to STOP the booster when the gas outlet pressure exceeds set point Manual Start & Stop Switch Safety Relief Valve Inlet & Outlet Pressure Gauges (dual Scale) 6-Digit Hour Meter Inlet & Outlet 5-Micron Filters Cooling Fan Outlet Shutoff Valve (Needle Type) Bleed Valve (Needle Type) STANDARD Automatic Low Pressure Limit Switch set to STOP & RESTART the booster when the gas inlet pressure drops below set point Automatic High Pressure Limit Switch set to STOP & RESTART the booster when the gas outlet pressure exceeds set point Remote Star & STOP Switch with 10-foot cord Flow Control gas Inlet Pressure regulator with full pressure bypass line Dual Outlet Pressure Control 4-Port Outlet Manifold Oxygen Cleaned to MIL-STD-1330D OPTIONAL ELECTRIC DRIVEN BOOSTER SYSTEMS RATED UP TO 14,500-PSI (1000 BAR) Series 2G Electric Driven Booster package is ideal for filling or topping off low-pressure and high-pressure bottles. Its two-stage and double acting design uses NO Belts or Pulleys, making it the quietest Electric Driven Booster in its class; only 63 dBA. Air cooled with its integrated cooling fan reducing the heat of compression for long seal life. SERIES 2G EGB100D SPECIFICATIONS: MOTOR: 2-HP, 1750/1440 RPM @ 60/50-Hz WEIGHT: 145-Lbs (65.9 Kg) VOLTAGES: 115 VAC, 20.4 Amps, 1-Phase, 60/50 Hz 220 VAC, 10.2 Amps, 1-Phase, 60/50 Hz 230 VAC, 5.8 Amps, 3-Phase, 60/50 Hz 460 VAC, 2.9 Amps, 3-Phase, 50 Hz 380 VAC, 3.0 Amps, 3-Phase, 50 Hz DIMENSIONS: 37”L x 11.5”H x 22”D (940x292x559 mm) LOW NOISE LEVEL: 63 dBA OPERATING SPEED: 43, 70, 88, 115 Cycles/min (CPM) Optional: Variable Frequency Drive PORTS (INLET/OUTLET): 1/4” or 3/8” NPT or 37 O Flare MAX. OUTLET PRESSURE: 14,500 PSI (1000 BAR) HYDRAULICS INTERNATIONAL, INC. ® (HII) CHATSWORTH, CALIFORNIA www.hiigroup.com (818) 407-3400 Made in the U.S.A. ISO 9001 & AS9100

RATED UP TO 14,500-PSI (1000 BAR) · 2019-03-29 · AIR DRIVEN GAS BOOSTERS Boosts pressure from 50 PSI (3.4 BAR) to 30,000 PSI (2068 BAR) Airline lubrication not required Lightweight,

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RATED UP TO 14,500-PSI (1000 BAR) · 2019-03-29 · AIR DRIVEN GAS BOOSTERS Boosts pressure from 50 PSI (3.4 BAR) to 30,000 PSI (2068 BAR) Airline lubrication not required Lightweight,

MODEL SELECTION TABLE:

Model 2G

Maximum PressurePSI (BAR) Minimum Gas

Inlet PressurePSI (BAR)

Maximum Discharge Flow Rate @ 70-CPM

SCFM (LPM)Inlet Outlet

TWO STAGE

0714 510 (35) 1,700 (117) 30 (2) 7.02 (199)

0730 220 (15) 4,500 (310) 30 (2) 3.12(88)

0750 115 (8) 7,500 (517) 30 (2) 1.7 (48)

1430 820 (57) 4,100 (283) 80 (6) 5.89 (167)

1450 450 (31) 7,500 (517) 80 (6) 3.25 (92)

1492 250 (17) 14,500 (1,000) 80 (6) 1.18 (33)

3050 2,200 (152) 7,200 (497) 300 (21) 6.93 (196)

3092 1,300 (90) 14,000 (966) 300 (21) 4.04 (114)

5092 4,200 (290) 12,500 (862) 500 (34) 7.36 (208)

DOUBLE ACTING

0707 800 (55) 800 (55) 30 (2) 21.9 (620)

1414 1,500 (103) 1,500 (103) 80 (6) 21.54 (610)

3030 3,500 (241) 3,500 (241) 300 (21) 22.22 (629)

5050 6,000 (414) 6,000 (414) 500 (34) 21.39 (606)

9292 6,000 (414) 13,000 (897) 800 (55) 12 (340)

CONTROLS:

■ Automatic High Pressure Limit Switch set to STOP the booster when the gas outlet pressure exceeds set point

■ Manual Start & Stop Switch■ Safety Relief Valve■ Inlet & Outlet Pressure Gauges (dual Scale)■ 6-Digit Hour Meter■ Inlet & Outlet 5-Micron Filters■ Cooling Fan■ Outlet Shutoff Valve (Needle Type)■ Bleed Valve (Needle Type)

STANDARD

■ Automatic Low Pressure Limit Switch set to STOP & RESTART the booster when the gas inlet pressure drops below set point

■ Automatic High Pressure Limit Switch set to STOP & RESTART the booster when the gas outlet pressure exceeds set point

■ Remote Star & STOP Switch with 10-foot cord■ Flow Control gas Inlet Pressure regulator with full

pressure bypass line■ Dual Outlet Pressure Control■ 4-Port Outlet Manifold■ Oxygen Cleaned to MIL-STD-1330D

OPTIONAL

ELECTRIC DRIVEN BOOSTER SYSTEMSRATED UP TO 14,500-PSI (1000 BAR)

Series 2G Electric Driven Booster package is ideal for filling or topping off low-pressure and high-pressure bottles. Its two-stage and double acting design uses NO Belts or Pulleys, making it the quietest Electric Driven Booster in its class; only 63 dBA. Air cooled with its integrated cooling fan reducing the heat of compression for long seal life.

SERIES 2G

EGB100D

SPECIFICATIONS:

MOTOR: 2-HP, 1750/1440 RPM @ 60/50-HzWEIGHT: 145-Lbs (65.9 Kg)VOLTAGES: 115 VAC, 20.4 Amps, 1-Phase, 60/50 Hz 220 VAC, 10.2 Amps, 1-Phase, 60/50 Hz 230 VAC, 5.8 Amps, 3-Phase, 60/50 Hz 460 VAC, 2.9 Amps, 3-Phase, 50 Hz 380 VAC, 3.0 Amps, 3-Phase, 50 HzDIMENSIONS: 37”L x 11.5”H x 22”D (940x292x559 mm)LOW NOISE LEVEL: 63 dBAOPERATING SPEED: 43, 70, 88, 115 Cycles/min (CPM) Optional: Variable Frequency DrivePORTS (INLET/OUTLET): 1/4” or 3/8” NPT or 37O FlareMAX. OUTLET PRESSURE: 14,500 PSI (1000 BAR)

HYDRAULICS INTERNATIONAL, INC.® (HII)CHATSWORTH, CALIFORNIA

www.hiigroup.com (818) 407-3400

Made in the U.S.A.

ISO 9001 & AS9100

Page 2: RATED UP TO 14,500-PSI (1000 BAR) · 2019-03-29 · AIR DRIVEN GAS BOOSTERS Boosts pressure from 50 PSI (3.4 BAR) to 30,000 PSI (2068 BAR) Airline lubrication not required Lightweight,

14 (396)

12(340)

10

(283)

8(227)

6 (170)

4 (113)

2 (57)

030 (2)

70 (5)

110 (8)

150 (10)

190 (13)

230 (16)

270 (19)

310(21)

350 (24)

390 (27)

430 (30)

470 (32)

510 (35)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-0714

43 cpm

115 cpm

88 cpm

70 cpm

6 (170)

5(140)

4 (113)

3(84)

2 (57)

1(28)

030 (2)

57 (4)

84 (6)

111 (7)

138 (9)

165 (11)

192 (13)

219(15)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-0730

43 cpm

115 cpm

88 cpm

70 cpm

30 (2)

47 (3)

64 (4)

81 (6)

115(8)

98(7)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-0750

3(85)

2.5(71)

2(57)

1.5(43)

1(28)

0.5(14)

0

43 cpm

115 cpm

88 cpm

70 cpm

80 (6)

163(11)

246(17)

329(23)

412(28)

495(34)

578(40)

661(46)

744(51)

827(57)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-1430

12(340)

10

(283)

8(227)

6 (170)

4 (113)

2 (57)

0

43 cpm

115 cpm

88 cpm

70 cpm

80(6)

127(9)

174(12)

221(15)

268(18)

315(22)

362(25)

409(28)

456(31)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-1450

6 (170)

5(140)

4 (113)

3(84)

2 (57)

1(28)

0

43 cpm

115 cpm

88 cpm

70 cpm

80(6)

96(7)

112(8)

128(9)

144(10)

160(11)

176(12)

240(17)

224(15)

208(14)

192(13)

256(18)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-1492

3(85)

2.5(71)

2(57)

1.5(43)

1(28)

0.5(14)

0

43 cpm

115 cpm

88 cpm

70 cpm

300 (21)

550(38)

800(55)

1050(72)

1300(90)

1550 (107)

1800 (124)

2050(141)

2300(159)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-3050

14 (396)

12(340)

10

(283)

8(227)

6 (170)

4 (113)

2 (57)

0

43 cpm

115 cpm

88 cpm

70 cpm

7(198)

6(170)

5(142)

4(113)

3(85)

257)

1(28)

0300(21)

400(28)

500(34)

600(41)

700(48)

800(55)

900(62)

1000(69)

1100(76)

1200(83)

1300(90)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-3092

43 cpm

115 cpm

88 cpm

70 cpm

(818) 407-3400 www.h i ig roup .com

PERFORMANCE CURVES

Page 3: RATED UP TO 14,500-PSI (1000 BAR) · 2019-03-29 · AIR DRIVEN GAS BOOSTERS Boosts pressure from 50 PSI (3.4 BAR) to 30,000 PSI (2068 BAR) Airline lubrication not required Lightweight,

500(34)

870(60)

1240(85)

1610(111)

1980(137)

2350(162)

2720(188)

3090(213)

3460(239)

3830(264)

4200(290)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-5092

14 (396)

12(340)

10

(283)

8(227)

6 (170)

4 (113)

2 (57)

0

43 cpm

115 cpm

88 cpm

70 cpm

40(1133)

35(991)

30(850)

25(708)

20(566)

15(425)

10(283)

5(142)

030(2)

140(10)

250(17)

360(25)

470(32)

580(40)

690(48)

800(55)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-0707

43 cpm

115 cpm

88 cpm

70 cpm

80(6)

290(20)

500(34)

710(49)

920(63)

1130(78)

1340(92)

1550(107)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-1414

40(1133)

35(991)

30(850)

25(708)

20(566)

15(425)

10(283)

5(142)

0

43 cpm

115 cpm

88 cpm

70 cpm

300 (21)

550(38)

800(55)

1050(72)

1300(90)

1550(107)

1800(124)

2050(141)

2300(159)

2550(176)

2800(193)

3050(210)

3300(228)

3550(245)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-3030

40(1133)

35(991)

30(850)

25(708)

20(566)

15(425)

10(283)

5(142)

0

43 cpm

115 cpm

88 cpm

70 cpm

500(35)

1114(77)

1728(119)

2342(161)

2956(204)

3570(246)

4184(288)

4798(331)

5412(373)

6026(415)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-5050

40(1133)

35(991)

30(850)

25(708)

20(566)

15(425)

10(283)

5(142)

0

43 cpm

115 cpm

88 cpm

70 cpm

60(1699)

50(1416)

40(1133)

30(850)

20(566)

10(283)

0600(41)

1200(83)

1800(124)

2400(165)

3000(207)

3600(248)

4200(290)

4800(331)

5400(372)

6000(414)

OU

TLET

FLO

W

SCFM

L/

MIN

INLET GAS PRESSURE PSI BAR

2G-9292

43 cpm

115 cpm

88 cpm

70 cpm

www.h i ig roup .com (818) 407-3400

VOLTAGE A 115 VAC, 24 amps, 1-Phase, 60/50 HzB 220 VAC, 12 amps, 1-Phase, 60/50 HzC 208/230 VAC, 6.8 amps, 3-Phase, 60/50 HzD 460 VAC, 3.4 amps, 3-Phase, 50 HzE 380 VAC, 5.0 amps, 3-Phase, 50 Hz

CONFIGURATION 0714 2-stage 3092 2-stage0730 2-stage 5092 2-stage0750 2-stage 0707 Double Acting1430 2-stage 1414 Double Acting1450 2-stage 3030 Double Acting1492 2-stage 5050 Double Acting3050 2-stage 9292 Double Acting

OPERATING SPEED 1 43-46 cycles/min 2 69-73 cycles/min 3 112-116 cycles/min 4 86-89 cycles/min VFD Variable Frequency Drive w/Potentiometer

MODIFICATION A Auto start/stop - low pressure limit switchB Auto start/stop - high pressure limit switchDO Dual Outlet pressure controlM4 4-Port Outlet ManifoldMX4 4-Port Outlet Manifold with gauges, on/off and bleed valvesR Remote start/stop switch with 10-foot cordP All vents connected to a common port (for O2 & H2 service)PR Pressure reducing regulator, check valve & relief valveCID2 Class I Divison II, Group B, C and D1330 O2 cleaned to MIL-STD 1330D1730 Watertight Enclosure NOTE: Addinganymodificationtostandard2Gpartnumberwillchangesystemtomodel HIHPG2-XXXXX followed by a 5-digit part number

2G-2G MODEL SELECTION SYSTEM

PERFORMANCE CURVES

Page 4: RATED UP TO 14,500-PSI (1000 BAR) · 2019-03-29 · AIR DRIVEN GAS BOOSTERS Boosts pressure from 50 PSI (3.4 BAR) to 30,000 PSI (2068 BAR) Airline lubrication not required Lightweight,

AIR DRIVEN GAS BOOSTERS■ Boosts pressure from 50 PSI (3.4 BAR) to 30,000 PSI (2068 BAR)■ Airline lubrication not required■ Lightweight, one-man portable■ Corrosion resistant including offshore environment■ Self-cooling using own exhaust air■ No electrical connections needed■ Wide range of models: single acting, double acting, two stage and double air drive configuration

© HYDRAULICS INTERNATIONAL, INC. 2018

OTHER HII QUALITY PRODUCTS

SYSTEMS■ Aircraft Ground Support Equipment (portable & stationary)■ Component Test Equipment■ Customer Designed Equipment■ Central Systems■ Commercial and Military Applications■ Self Propelled Aerial Lift Truck

COMPONENTS■ Check valves - up to 20,000 PSI (1379 BAR), up to 2”■ Needle valves - straight or angled to 5,000 PSI (345 BAR)■ In-line filters rated to 5,000 PSI (345 BAR), 3 to 25 micron■ Double acting hand pumps - to 3,000 PSI (207 BAR)■ Pressure relief valves - to 60,000 PSI (4137 BAR)

AIR DRIVEN AIR PRESSURE AMPLIFIERS■ Boosting shop air to pneumatic tools, cylinders and devices■ Boosting shop air to drive high-pressure pneumatic diaphragm transfer pumps■ Boosting shop air to start oilfield and marine diesel engines■ Maximizing efficiency at pneumatic workstations or machinery■ Tire pressure top off on large mining vehicles■ Replace bottled nitrogen for gas testing, lab or production, up to 700 psi (48.3 BAR)

AIR DRIVEN LIQUID PUMPS■ Self lubricating■ No electrical power needed■ Portable, lightweight and economical■ Wide range of models in 3”, 5 3/4” and 7” drive sizes■ Pressures up to 80,000 PSI (5517 BAR)■ All models are rated for plain water or oil■ Ideal for OEM applications

FLOWMETRICS■ Liquid Flowmeters - to 15,000 GPM (56,781 lit/min)■ Gas Flowmeters - to 15,000 CFM (425 Nm3/min)

Made in the U.S.A.

HYDRAULICS INTERNATIONAL, INC.® (HII)9201 Independence Avenue, Chatsworth, CA 91311 USA

Tel: (818) 407-3400 • Fax: (818) 407-3428 • Email: [email protected]