Upload
nguyendung
View
300
Download
2
Embed Size (px)
Citation preview
RecoverPoint & RecoverPoint for Virtual Machines, What’s new in 2017
Yair Cohen, Director of Product Management, RecoverPoint Chris Mielke - Director of Infrastructure, Drake University
© Copyright 2017 Dell Inc. 2
Dell EMC Notifications
Forward Looking Statements Notice
This roadmap document contains “forward-looking statements” as defined under the Federal Securities Laws. Actual results or deliverables could differ materially from those projected in the forward-looking statements as a result of certain risk factors, including but not limited to: (i) adverse changes in general economic or market conditions; (ii) delays or reductions in information technology spending; (iii) risks associated with acquisitions and investments, including the challenges and costs of integration, restructuring and achieving anticipated synergies; (iv) competitive factors, including but not limited to pricing pressures and new product introductions; (v) the relative and varying rates of product price and component cost declines and the volume and mixture of product and services revenues; (vi) component and product quality and availability; (vii) the transition to new products, the uncertainty of customer acceptance of new product offerings and rapid technological and market change; (viii) insufficient, excess or obsolete inventory; (ix) war or acts of terrorism; (x) the ability to attract and retain highly qualified employees; (xi) fluctuating currency exchange rates; and (xii) other one-time events and other important factors disclosed previously and from time to time in EMC’s filings with the U.S. Securities and Exchange Commission. EMC disclaims any obligation to update any such forward-looking statements after the date of this roadmap document.
Copyright © 2017 Dell EMC Corporation. All rights reserved
ROADMAPS CAN CHANGE
© Copyright 2017 Dell Inc. 3
RecoverPoint Family Two Great Products For Different Use Cases
Data Protection for Storage Arrays XtremIO, VMAX All Flash, Unity , VNX, VNXe, VNX-F, ScaleIO and Non EMC Storage Using VPLEX
RecoverPoint
RecoverPoint for VMS Data Protection for Virtual Machines VMware Environment
© Copyright 2017 Dell Inc. 4
RecoverPoint Family Use Cases
Human errors Data corruptions Virus attacks
Natural disasters Accidents Utility outages Technical
malfunctions
Data center move Backup from copy Test & Dev
Disaster Recovery
Operational Recovery
Data Migration and Reuse
© Copyright 2017 Dell Inc. 5
RecoverPoint Family Operations
Test PiT image, Move between PiT (DVR like) and Promote directly without restarting test for each PiT
Test a Copy / Test and Promote
Restore Production In-place Restore of Production Copy from Replica (local or remote) by sending back changes only (Ideal for Operational Recovery)
Failover Failover to Replica Copy either with Reverse Replication or without
© Copyright 2017 Dell Inc. 6
Automated Protection Flow Protect a single or multiple virtual machines
Right click to protect VMs
Consistency Group
Policy Target VM Journal
Protected! Add to existing or create a new CG
Set RPO Sync/Async
Replica Datastore
Journal Datastore
1 2 3 4
• Automatically discover VMDK/VM configuration • Automatically create target VM & provision VMDKs and journals
• Target VM pre-seeding is also supported • Automatically replicate VM HW changes¹ & protect new VMDKs¹,²
Automatic provisioning fits 90% of customers use cases!
¹Can be turned off ²VMDK can also be excluded
© Copyright 2017 Dell Inc. 7
Automated Recovery Flow Quickly Test Point-in-Time Image and Directly promote to Recover
Select Scope
Select Image
Testing Network
Test Copy!
Consistency Group/ Group Set
Point-in-Time selection
Use dedicated or “bubble”
Network
Promote
Failover/ Failback/ Production Restore
• Select image access scope from a single VM up to the entire environment • Set testing network - use dedicated or create new isolated (“Bubble”) network • Pre-defined orchestration is applied automatically during the image access • Continuous production VM protection while testing the Point-in-Time image
1 2 3 Initiate Image Access
DVR-like scroll between PiT
What’s New in RecoverPoint?
RecoverPoint for XtremIO
X2
RecoverPoint for VMAX
RecoverPoint for ScaleIO
© Copyright 2017 Dell Inc. 9
RecoverPoint for VMAX
• NEW RecoverPoint for VMAX All Flash • Snapshot Based Replication using SnapVX
Homogenous and Heterogeneous Replication
Asynchronous local and remote replication
Minimum snapshot interval of 1 minute
© Copyright 2017 Dell Inc. 10
Snapshot Based Replication – How does it work?
RPAs RPAs
Replica
Journal
App Host
WAN IP or FC
Primary / Production
Site
Replica / DR Site
1. RPAs and VMAX zoned to each other via FC
2. RP environment setup on the array
App Host
Production
© Copyright 2017 Dell Inc. 11
Snapshot Based Replication – How does it work?
RPAs RPAs Cluster
First Snapshot First Initialization Snapshot
First snapshot is created by RecoverPoint
The first snapshot is transferred and stored in the replica site by RecoverPoint
App Host
Production Replica
Journal
App Host
WAN IP or FC
Primary / Production
Site
Replica / DR Site
© Copyright 2017 Dell Inc. 12
Snapshot Based Replication – How does it work?
RPAs RPAs Cluster
First Snapshot First Initialization Snapshot
New Snapshot
Following snapshots are created at a frequency derived from RPO setting in the RP CG’s link policy
App Host
Production Replica
Journal
App Host
WAN IP or FC
Primary / Production
Site
Replica / DR Site
© Copyright 2017 Dell Inc. 13
Snapshot Based Replication – How does it work?
RPAs RPAs Cluster
First Snapshot First Initialization Snapshot
New Snapshot
DIFF SCSI
RecoverPoint sends vendor specific SCSI command to diff between the last transferred snapshot and the newly created snapshot
App Host
Production Replica
Journal
App Host
WAN IP or FC
Primary / Production
Site
Replica / DR Site
© Copyright 2017 Dell Inc. 14
Snapshot Based Replication – How does it work?
RPAs RPAs
First Snapshot First Initialization Snapshot
New Snapshot
Snap delta
DIFF Reply
RecoverPoint receives changes bit map from VMAX (64K tracking granularity) to track changes between snapshots
App Host
Production Replica
Journal
App Host
WAN IP or FC
Primary / Production
Site
Replica / DR Site
© Copyright 2017 Dell Inc. 15
Snapshot Based Replication – How does it work?
RPAs RPAs Cluster
First Snapshot First Initialization Snapshot
New Snapshot Snap delta
Snap delta
Snap delta
RecoverPoint will copy only the differences between the last transferred snapshot and the new snapshot to the replica site
App Host
Replica
Journal
App Host
WAN IP or FC
Primary / Production
Site
Replica / DR Site
Production
© Copyright 2017 Dell Inc. 16
RecoverPoint for XtremIO X2
• NEW RP for XtremIO new platform (X2-S and X2-R) • Journals and replica auto provisioning • 2x Scale & Performance
Max snaps per replicated CG 1024 Max volumes per CG 1024 Max protected volumes per cluster 1500 Max IOPS per RPA (up x8 RPA) 75K Max copies per CG 4 Max # volumes per XtremIO array 16K
© Copyright 2017 Dell Inc. 17
Journal & Replica User Volumes Auto-Provisioning (XtremIO)
Auto create volumes
on target array Map Initiator Group Pair Source and
Target volumes Create Journal
Select Volumes to
protect Provisioning Mode
(Auto, Manual) Target Array
1 2 3
Replication is
started automatically
© Copyright 2017 Dell Inc. 18
RecoverPoint for ScaleIO
• New RP for ScaleIO w/ Physical RPAs
Replication between SIO to SIO Heterogeneous Replication
between SIO and Other arrays Use RPA to replicate ScaleIO for
better performance
IP WAN
ScaleIO Cluster
Journal Repository Journal Repository Remote Copy
RPAs RPAs
What’s new in RecoverPoint for VMs
RP4VMs for EHC
RP4VMs for VSAN 6.x
Failover Network
Simpler Re-IP
Enhanced DR
Orchestration
Easier Deployment
© Copyright 2017 Dell Inc. 20
RecoverPoint For Virtual Machines Operational And Disaster Recovery To Any Point In Time
• Disaster Recovery and Operational Recovery with VM-level granularity
• Integrated Management & Orchestration with VMware’s vCenter GUI
• Test, failover, failback and production recovery to any point-in-time per VM
• Software Only - Hypervisor based replication solution
• Storage agnostic
© Copyright 2017 Dell Inc. 21
EASIER SIMPLER BETTER Easier Deployment
New Connect Clusters Wizard Easier Maintenance
Change to IP Communication
© Copyright 2017 Dell Inc. 22
Network Setup Simplification
• No iSCSI (IP Connectivity between Splitter and vRPA) • Single VM on Remote Site (No Shadow VM on Remote Site)
EASIER SIMPLER BETTER
Production Site
vCenter vCenter Remote Site
WAN
1 VMware
ESXi 1 VMware
ESXi splitter splitter
Virtual Appliance Cluster
Virtual Appliance cluster
Plugin Plugin
© Copyright 2017 Dell Inc. 23
Single vRPA vs vRPA Cluster
Single vRPA vRPA Cluster
• Low footprint • VMWare HA only • Smaller Environment e.g. VxRail • ROBO, POC, Tier-2
• Higher footprint • Cluster HA + VMWare HA • Larger Environment • Enterprise Tier-1
EASIER SIMPLER BETTER
© Copyright 2017 Dell Inc. 24
New Dashboard – Automatically remove standalone vRPA cluster using a dedicated external Uninstaller
tool • Single Pane of glass for all RP4VMs systems • Easier tracking of protection status
• Monitor: – System health status – vCenter Protection summary – CGs status – System alerts and statistics
• Zoom-in to Protection SLA per CG:
– RPO, Journal lag, Protection Window and Snapshot list view
–
EASIER SIMPLER BETTER
© Copyright 2017 Dell Inc. 25
vRPA Networking Considerations
Use Case SMB, Tier-2 Enterprise, Tier-1
# of vRPAs Single vRPA vRPA cluster
Port Groups 1 – All in One or
2 - Separated data path 2 – Separated data path
VMKernel ports 1 1
DHCP Optional Optional
• Easier networking configuration • Flexible number of port groups (1-4) • DHCP
EASIER SIMPLER BETTER
© Copyright 2017 Dell Inc. 26
New design for Re-IP
Manage IP settings through UI No scripts required No manual operations Single click to retrieve protected VM
settings Supports Microsoft and Linux
• Easier IP settings per VM via UI • Automatic MAC address replication
* Script based Re-IP capabilities is also available for backward compatibility
EASIER SIMPLER BETTER
© Copyright 2017 Dell Inc. 27
Pre-Defined Failover Network Configuration Assign Networks to be used when Failing-Over
• Define failover network per CG:
• Testing Point-in-Time: – User can choose the pre-defined failover network,
or a dedicated isolated network
• Promote to failover flow: – User can continue with current test network, or
use the pre-defined failover network
Pre-Defined Failover Network Configuration
• Pre-define failover network per CG
© Copyright 2017 Dell Inc. 28
Enhanced Power-Up sequence
Set priority of VMs within a Consistency Group
Set priority of CGs within a Group Set Priorities range between 1 (first) to 5 (last) Power-up sequence will stop if a critical
VM fail to start
• Acknowledge VM boot before powering up next VM
* Script based Re-IP capabilities is also available for backward compatibility
EASIER SIMPLER BETTER
© Copyright 2017 Dell Inc. 29
Scale & Performance
• Improved Scale and Performance
EASIER SIMPLER BETTER
V 4.3 V 5.1 # of Protected VMS per VC 2000 5000 2.5x # of CGs per Cluster 128 256 2x Throughput per vRPA 150 MB/s 300 MB/s 2x
Registered VM per VC 15K Unlimited
DRAKE University RP4VMs Experience
© Copyright 2017 Dell Inc. 31
About Drake
© Copyright 2017 Dell Inc. 32
Business goals
© Copyright 2017 Dell Inc. 33
ARCHITECTURE
© Copyright 2017 Dell Inc. 34
Product Recommendations
© Copyright 2017 Dell Inc. 35
vRealize Automation Extension – Automatically remove standalone vRPA cluster using a dedicated external Uninstaller
tool • New RP4VMs Stand-Alone vRealize
Automation extension
• Self-service provisioning of instances with protection
• Assign protection SLA to blueprints • Replica VMs and RP4VM CGs are
automatically created • Day 2 actions available for end-users
– Bookmark, Test image, Failover, Recover Production
EASIER SIMPLER BETTER
Want to try RP4VMs vRealize Extension?
Send Request to: [email protected]
RP4VMs Licensing
© Copyright 2017 Dell Inc. 38
How to license RP4VMs ?
Per Socket < 1000 VMs / 150
Sockets
DP Suite for VMWare
DP Suite for Enterprise Per TB > 1000 VMs / 150
Sockets
RP4VMs Stand-alone Per VM
(Production Only) > 1000 VMs
RP4VMs Pack for SC/Unity 100/300 VMs pack
© Copyright 2017 Dell Inc. 39
ReoverPoint for VMs Packs For SC/Unity
Large pack* Small pack*
For SC9000, SC7020, Unity600, Unity500. For SC5020/4020 SCv2/v3 Unity400/300
• Lower price than LUN-level replication • Lower price than direct RP4VM • Multi-site replication at the same price
Cost Effective • Local/remote replication (up to 4 sites) • Full DR/OR functionality • Orchestration & automation
Best Value
Heterogeneous replication solution to/from any array (VMWare env. only) Select one or more packs according to the array capacity
*Large -> 300 VMs. Small -> 100 VMs
RP4VMs & VSAN
© Copyright 2017 Dell Inc. 41
Better Together – RP4VMs and VSAN
Virtual SAN
Any Deployment Choice
VxRail Ready Node Build Your Own
Any vSphere Datastore
VMFS NFS VVOL
Any Application
vSphere
© Copyright 2017 Dell Inc. 42
Virtual SAN + RecoverPoint for VMs
4
vSphere + Virtual SAN
vCenter RP4VMs Plugin
vSphere APIs for IO Filters (VAIO)
vSphere + Virtual SAN
RP vRPA
RP vRPA
vCenter based Management: • Policy-based provisioning • Monitoring of protection status (RPOs, Journal state etc.)
Local Protection: • Production VM restore to any PIT (“DVR for VMs”) • Multi-VM consistency groups
Remote Protection and DR: • Recovery of single VMs or multiple VMs (at a
consistency group or group set level) • SRM-style orchestration of recovery procedures
RP vRPA
RP vRPA
© Copyright 2017 Dell Inc. 43
Want To Win A Levitating Death Star Speaker?
• Follow @DellEMCProtect while at Dell EMC World
• 2 Winners will be chosen daily from
Monday May 8 to Thursday May 11 • All winners will be notified through
Twitter Direct Message
NO PURCHASE NECESSARY. Ends 05/11/2017. To enter and for Official Rules, visit http://thecoreblog.emc.com/dell-emc-world-follow-win-sweepstakes-2017/
Thank You !