35
Informatica ® Corporation Informatica Version 9.5.1 Release Notes December 2012 Copyright (c) 1998-2012 Informatica Corporation. All rights reserved. Contents Informatica Domain................................................................................. 2 Informatica Domain Installation......................................................... 2 Informatica Domain Closed Enhancements................................................ 6 Informatica Domain Fixed Limitations.................................................... 6 Informatica Domain Known Limitations................................................... 9 PowerCenter...................................................................................... 10 PowerCenter Closed Enhancements.................................................... 10 PowerCenter Fixed Limitations........................................................ 11 PowerCenter Known Limitations....................................................... 14 PowerCenter Third-Party Limitations.................................................... 15 Informatica Analyst ................................................................................ 16 Informatica Analyst Closed Enhancements............................................... 16 Informatica Analyst Fixed Limitations................................................... 16 Informatica Analyst Known Limitations.................................................. 17 Informatica Data Transformation.................................................................... 18 Informatica Data Transformation Fixed Limitations......................................... 18 Informatica Data Transformation Known Limitations........................................ 18 Informatica Data Quality............................................................................ 19 Informatica Data Quality Closed Enhancements........................................... 19 Informatica Data Quality Fixed Limitations................................................ 19 Informatica Data Quality Known Limitations............................................... 20 Informatica Developer.............................................................................. 21 Informatica Developer Closed Enhancements............................................. 21 Informatica Developer Fixed Limitations................................................. 21 Informatica Developer Known Limitations................................................ 25 Informatica Developer Third-Party Limitations............................................. 30 IN_RLN_95100_0001 1

Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

Informatica® CorporationInformatica

Version 9.5.1Release Notes

December 2012Copyright (c) 1998-2012 Informatica Corporation. All rights reserved.

ContentsInformatica Domain. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Informatica Domain Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Informatica Domain Closed Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Informatica Domain Fixed Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Informatica Domain Known Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

PowerCenter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

PowerCenter Closed Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

PowerCenter Fixed Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

PowerCenter Known Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

PowerCenter Third-Party Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Informatica Analyst. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Informatica Analyst Closed Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Informatica Analyst Fixed Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Informatica Analyst Known Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Informatica Data Transformation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Informatica Data Transformation Fixed Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Informatica Data Transformation Known Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Informatica Data Quality. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Informatica Data Quality Closed Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Informatica Data Quality Fixed Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Informatica Data Quality Known Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Informatica Developer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Informatica Developer Closed Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Informatica Developer Fixed Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Informatica Developer Known Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Informatica Developer Third-Party Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

IN_RLN_95100_0001 1

Page 2: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

Metadata Manager. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Metadata Manager Fixed Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Metadata Manager Known Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Informatica Global Customer Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

This document contains important information about installation, fixed limitations, and known limitations forthe Informatica domain, PowerCenter, Data Analyzer, Metadata Manager, Informatica Data Explorer,Informatica Data Quality, Informatica Data Services, and Informatica Data Transformation.

Informatica Domain

Informatica Domain Installation

Informatica Domain Patches and Libraries

Platform Java 6 Patch

Linux-x64 1.6.0_31-b04

Linux-x86 1.6.0_31-b04

zLinux IBM Java for zLinux 1.6.0 SR9 FP1

Linux-x64 1.6.0_31-b04

Linux-x86 1.6.0_31-b04

zLinux IBM Java for zLinux 1.6.0 SR9 FP1

Linux-x64 1.6.0_31-b04

Linux-x86 1.6.0_31-b04

zLinux IBM Java for zLinux 1.6.0 SR9 FP1

Linux-x64 1.6.0_31-b04

Linux-x86 1.6.0_31-b04

zLinux IBM Java for zLinux 1.6.0 SR9 FP1

Solaris-sp64 1.6.0_31-b04

Solaris-x64 1.6.0_31-b04

Solaris-sp64 1.6.0_31-b04

Solaris-x64 1.6.0_31-b04

Win-x64 1.6.0_31-b05

2 IN_RLN_95100_0001

Page 3: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

Platform Java 6 Patch

Win-x86 1.6.0_31-b05

AIX 64-bit IBM Java for AIX 1.6.0 SR9 FP2

AIX 64-bit IBM Java for AIX 1.6.0 SR9 FP2

HP 1.6.0.04

To run the AXIS samples or any client application developed with AXIS, you need AXIS 1.4. You can findAXIS libraries in $INFA_HOME/server/samples/WebServices/lib/axis-1.4.

Running the Informatica JDBC and ODBC Driver Installation or Upgrade on Linux

The successful Informatica JDBC and ODBC Driver installation or upgrade displays an error status message.

If you are running the Informatica JDBC and ODBC Driver installation or upgrade on Linux 32-bit, thefollowing error message appears in the Post-Upgrade Summary panel and theInformatica_<Version>_Services_InstallLog.log log file.

Status: ERROR

You can ignore the message.

(CR 326553)

Upgrading Profiles

When you create or upgrade a profiling warehouse, the create or upgrade task fails if one of the followingconditions is true:

¨ You create a profiling warehouse on a Microsoft SQL Server non-default schema.¨ You upgrade the profiling warehouse on a Microsoft SQL Server non-default schema from version 9.1.0 to

9.5.1.

Before you create or upgrade the profiling warehouse, make sure that the current database schema is thedefault one for the database connection login.

(CR 326138)

If you change the schema of a Microsoft SQL Server profiling warehouse database to a non-default schemaafter upgrade from version 9.1.0 to 9.5.1 and export column profile results from Informatica Analyst toMicrosoft Excel, the export task fails with an invalid object error.

(CR 326322)

When you reload a profile model after you upgrade from version 9.5.0 to version 9.5.1, the foreign keyinference option for enterprise discovery Use top ranked keys is incorrectly set to -5 instead of 1.

(CR 324819)

IN_RLN_95100_0001 3

Page 4: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

Installing Informatica Services or Running the Informatica Pre-Installation (i9Pi)System Check Tool on Solaris or Linux

If you install the Informatica services or run the Informatica Pre-Installation (i9Pi) System Check Tool onSolaris or Linux, the installer displays the Available Disk Space as 0 MB and the installation stops.

If you install the Informatica services or run the Informatica Pre-Installation (i9Pi) System Check Tool on aSolaris or Linux machine with at least 1 TB of disk space, the installer displays the Available Disk Spacevalue as 0 MB due to the following Java issue: http://bugs.sun.com/bugdatabase/view_bug.do?bug_id=6815768.

To work around the installation issue, before you install the Informatica services, verify that your machinemeets the minimum disk space requirements for the installation, and then run the following command todisable the disk space check:

Using a C shell:setenv DISK_SPACE_CHECK_ENABLED false

Using a Bash shell:export DISK_SPACE_CHECK_ENABLED =false

To work around the Informatica Pre-Installation (i9Pi) System Check Tool issue, verify that your machinemeets the minimum disk space requirements for the installation.

(CR 326100)

Upgrading the Gateway Node

If you upgrade the domain, master node and gateway nodes, at the end of the gateway node upgrade, theInformatica Administrator Home Page URL address provided in the Post-Upgrade Summary panel is not valid.

After you upgrade the domain, master node and gateway nodes, at the end the gateway node upgrade, theURL address in the Post-Upgrade Summary panel is not valid because it points to the InformaticaAdministrator port number. The URL address should point to the gateway node port number.

To access the Informatica Administrator home page from the gateway node, when you enter the URL in theaddress field, replace the Informatica Administrator port number with the node port number. For example,type http://<host>:<gateway node port number>/administrator>.

(CR 326009)

Running the Informatica Data Services ODBC Driver Upgrade on HP-UX and AIX

During the Informatica Data Services ODBC Driver upgrade, the ODBC binary files that have beensuccessfully installed appear as failed.

If you are upgrading the Informatica Data Services ODBC driver on HP-UX or AIX, when you perform theupgrade, a warning message appears in the Post-Upgrade Summary panel and the following log file:Informatica_<Version>_Services_InstallLog.log.

Destination: /home/toolinst/INFA_Automation/AIX/JDBC1/950/950_JDBCInst/odbcdrv/libinfadsodbc.soStatus: WARNINGAdditional Notes: WARNING - Source file /home/toolinst/INFA_Automation/AIX/JDBC1/950/950_JDBCInst/odbcdrv/libinfadsodbc.so does not exist.

You can ignore the message.

(CR 324533)

4 IN_RLN_95100_0001

Page 5: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

Uninstalling Informatica Services or Clients on Windows

If you install the Informatica services and Informatica clients on the same machine, uninstalling Informaticaremoves the ODBC directory. This issue affect installation on Windows.

When you install the Informatica services, the installer creates an ODBC entry that points to the<InformaticaInstallationDir>\ODBC7.0 directory. If you install the Informatica clients on the same machine,the installer updates the ODBC entry to point to the <InformaticaInstallationDir>\clients\tools\ODBC7.0directory. If you uninstall the Informatica clients, the uninstaller deletes the <InformaticaInstallationDir>\clients\tools\ODBC7.0 directory, to which the ODBC entry still points.

Similarly, when you install the Informatica clients, the installer creates an ODBC entry that points to the<InformaticaInstallationDir>\clients\tools\ODBC7.0 directory. If you install the Informatica services on thesame machine, the installer updates the ODBC entry to point to the <InformaticaInstallationDir>\ODBC7.0directory. If you uninstall the Informatica services, the uninstaller deletes the <InformaticaInstallationDir>\ODBC7.0 directory, to which the ODBC entry still points.

To work around the issue, after you uninstall the Informatica services or clients, restore the ODBC7.0 folderto the original location.

1. Before you uninstall the Informatica services or clients, copy the ODBC7.0 directory to a temporarydirectory on your local drive. For example, if you are uninstalling the Informatica services, copy the<InformaticaInstallationDir>\ODBC7.0 directory and its contents to C:\temp.

2. Perform the uninstallation.

3. After you uninstall the Informatica services or clients, recreate the ODBC7.0 directory path.

4. Copy the ODBC7.0 directory from the temporary directory to the recreated directory. For example, if youuninstalled the Informatica services, copy the ODBC7.0 folder and its contents to<InformaticaInstallationDir>.

(CR 322656)

Running the Informatica Services Installer in Graphical Mode on UNIX

If you are installing Informatica services on the Solaris 11 platform, the installer does not launch in graphicalmode.

When you run install.sh and press g to launch the installer in graphical mode, the installer does not respond.

Perform the Informatica services installation in console or silent mode.

(CR 319191)

IN_RLN_95100_0001 5

Page 6: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

DataDirect SequeLink Connectivity in PowerCenter

DataDirect SequeLink drivers extend access to data sources with limited platform or API access. TheSequeLink 6.0 drivers are installed with Informatica services in the following location:<InformaticaInstallationDir>\tools\Sequelink

Informatica Domain Closed Enhancements

CR Description

306505 The following error occurs when you filter logs with the custom filter in the Administrator tool in the Eastern Standard time zone:"Start date cannot be greater than end date."

304631 When the Data Integration Service reuses a DTM process to run an SQL data service query or a web service request, the DataIntegration Service does not run a query to verify that the lookup table exists in the database.

292304 Log files generated by the Data Integration Service include a timestamp in the file name.

Informatica Domain Fixed Limitations

Review the Release Notes of previous releases for information about previous fixed limitations.

CR Description

326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you select theoption to install or upgrade Data Transformation engine only, the following message appears: "Do you want to continue theInformatica Server Installation (y/n)."

323241 The Informatica domain passes the authentication information as clear text if you run the Test Connection option when youcreate an ODBC connection.

323005 Node shut down with a null pointer exception in the BEEP connection handler.

320596 Stack trace printed to the domain log includes methods that can be used to decrypt Informatica user passwords.

320165 Gateway nodes shut down with a fatal error if you change the Administrator password after you start the nodes.

319472 When you upgrade to Informatica Services 9.5.0, if the domain database uses a named instance, the installer does not pick upthe domain credentials from nodemeta.xml. As a result, the upgrade fails.

319021 The Informatica Pre-Installation (i9Pi) System Check verifies the availability of port number 6010 during the default port rangecheck. If port number 6010 is not available, the following message appears: [Fail] Port range is 6,005 - 6,010. Some ofthe port numbers within the port range are not available for the Informatica installation. Stop theapplication service that is running within the port range or specify a different port range. The Informaticainstaller does not use port number 6010, so it should not be included in the port range check.

315572 During the Informatica Pre-Installation (i9Pi) System Check, the Microsoft SQL Server Case Sensitivity parameter that haspassed the check appears as failed in the System Check Summary panel.

315243 If you are installing or upgrading Informatica in console mode and on the Solaris x64 or zLinux platform, the following messageappears:"To verify whether a machine meets the system requirements for an Informatica installation, run the Pre-Installation SystemCheck Tool (i9Pi) before you start the installation process. You can find the i9Pi tool in the following directory: /i9Pi".

6 IN_RLN_95100_0001

Page 7: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

314769 During the Informatica Pre-Installation (i9Pi) System Check, the AUTO_RUNSTATS parameter that has passed the checkappears as failed in the System Check Summary panel.

314638 If you are installing or upgrading Informatica in console mode and you specify a custom JDBC connection string during theInformatica Pre-Installation (i9Pi) System Check, install.sh command line error messages appear.

314506 If you install the Informatica services on AIX 6.1, the installer does not check the minimum AIX technology level. If you installInformatica on an unsupported AIX 6.1 technology level, the installer continues the installation without warning.

314086 The Administrator tool allows insecure HTTP methods such as Options and Delete.

312313 If you use LDAP authentication, the Informatica domain hangs if the connection to the LDAP server terminates.

311553 If you are installing or upgrading Informatica in console mode, the following message appears after you press c to start theinstallation:"Preparing SILENT Mode Installation..."

309105 The Informatica Data Services ODBC Driver 9.5 does not load with the driver manager in AIX systems.

308755 The workflow log file does not include the thread name for each log event.

308754 The Informatica domain does not log the tomcat events for a node in Windows.

308752 The administrator.log file does not contain the thread name field.

307188 The Administrator tool takes a long time to load over a wide area network.

306938 Informatica domain shuts down with a Java out of memory error.

306111 You cannot create a Data Integration Service in Informatica Administrator on non-English operating systems.

305851 You cannot cancel or abort a workflow when a Command task has spawned a new process that is still running.

305523 Show Query Plan runs continuously when you query an SQL data service that contains data quality transformations.

305455 Data object caching does not work on IBM DB2 for data objects that contain binary columns with precision that exceeds 256bytes. The Data Object Cache Manager creates empty tables in the cache database that cannot be used for storage.

305412 When the Maximum Session Size property for the Data Integration Service is set to a value higher than 2 GB, mappings fail torun from the Developer tool.

305047 The Administrator tool might become unresponsive if the domain fails over when the Administrator tool is not running on themaster gateway node.

304882 The Monitoring tab does not sort newly added jobs by start time when there are multiple jobs displayed in list view.

304769 An ODBC DSN failure occurs when business intelligence tools try to consume the Informatica Data Services ODBC Driver 9.5that was installed as part of the Informatica server installation.

304285 A DIAG [IM003] error occurs because WinSQL cannot load the Informatica Data Services ODBC Driver 9.5.

304225 When you use the Administrator tool to change a worker node to a gateway node, the change does not occur.

IN_RLN_95100_0001 7

Page 8: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

303977 When you create a Data Integration Service using the infacmd dis CreateService command, you cannot set the HTTP protocoltype to HTTPS or Both.

303975 If you upgrade to version 9.5.0 and start the Data Integration Service before you upgrade the Model Repository Service, theWorkflow Service Module does not properly initialize.

303801 The Data Integration Service Process ignores the Storage Directory property for result set caches. Similarly, it ignores the"ResultSetCacheOptions.StorageDirectory" option when you run the infacmd dis UpdateServiceProcessOptions command.

303525 When you cancel a business intelligence tool connection to an SQL data service in Informatica Administrator, the businessintelligence tool shuts down unexpectedly.

300671 When you install the Informatica Data Services ODBC Driver 9.5 on a machine with an earlier version of Informatica Developer,the driver does not work.

299880 You cannot view users that are locked out of the domain in the Account Management tab of the Administrator tool when LDAPusers are being synchronized.

299203 The workflow log displays only the first Notification task recipient that is not valid instead of displaying all recipients that are notvalid.

297715 When you redeploy an updated application that contains a workflow, the Monitoring tab clears the monitoring history of previousruns of the workflow.

294784 You cannot provide a relative path in the infacmd oie ExportObjects command when you export objects from the Modelrepository.

294016 The Data Integration Service grid cannot distribute workflow tasks and profiling jobs across multiple nodes unless you enablethe Mapping Service Module for the Data Integration Service.

293723 If you test an ODBC connection, but you did not configure valid values for the $ODBCHOME and $ODBCINI environmentvariables, the following error appears:[[DataDirect][ODBC lib] Data source name not found and no default driver specified]

292598 A workflow Notification task logs an unexpected or internal error message when SMTP authentication is incorrectly configuredfor the Data Integration Service.

292536 The Analyst Service staging database field displays SAP connections.

290371 The domain log does not display the client node name.

283868 High-availability failover does not occur in a domain with multiple gateway nodes.

281958 Processes do not failover properly when a node shuts down in a domain with multiple gateway nodes.

286436 When you run large jobs, such as a profile on 100 tables, the Monitoring tab of the Administrator tool shows a script error.

275827 The Administrator tool on a different locale takes twice as long to load than with the English locale.

264046 When you click the monitoring statistics hyperlink in the Monitoring tab of the Administrator tool, the window does not show alljobs by default.Workaround: To view all jobs, remove the default filter on the list of jobs.

8 IN_RLN_95100_0001

Page 9: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

Informatica Domain Known Limitations

CR Description

326894 The Content Management Service does not verify that you have Edit Reference Table Data privileges when you perform asearch and replace operation on reference table data in the Analyst tool.

325968 The Abort option is disabled under the Requests tab in the Connection page when you a run an SQL data service request.Workaround: You can abort the request from the Requests page.

323289 When you use the infacmd cms CreateService command to create a Content Management Service, the operation does notvalidate the following command options: Model Repository Service name, user name, and password.

323276 An ODBC client application might stop unexpectedly if it uses the Informatica Data Services ODBC driver to connect to multiplevirtual tables and issue multiple queries against the tables at the same time.

323196 If you restart the Data Integration Service with the Abort disable option when you run a mapping on a Hadoop cluster, scriptand Hive query incorrectly display the status as completed instead of aborted.

322699 The following error appears when you try to fetch logs in the Administrator tool:"Could not fetch the logs as the cursor object is too large. Please re-apply the filters to narrow down the logs search."

320089 The Administrator tool hangs or a script error occurs when you monitor a large number of concurrent jobs.

320085 After you recycle the Data Integration Service with the abort option, mappings that were running when you recycled the DataIntegration Service are in the Unknown state.

319930 The Content Management Service does not verify that a user has Edit Reference Metadata privileges when a user editsreference table metadata. You can select or clear the Edit Reference Metadata privilege for users in the Administrator tool. Allusers can edit reference table metadata regardless of the option setting.

314139 If you run infacmd rtm Import to create a reference table and you do not have create or edit permissions, the import commandcan create an empty folder at the path you specify.

313757 After you recycle the Data Integration Service with the abort option, mappings that were running when you recycled the DataIntegration Service are in the Unknown state.

312981 You cannot filter domain plug-ins by the Name column in the Administrator tool.

309300 When the Data Integration Service creates a DTM process to execute a web service operation mapping that contains a lookup,FINEST session log messages do not include the SELECT 1 dummy statements that verify that the lookup table exists in thedatabase.

308809 When the Data Integration Service maximum heap size is decreased to 70 megabytes, the Data Integration Service encountersa Java heap memory leak for a Java transformation.

305576 The Informatica Data Services ODBC Driver 9.5 does not work if Transport Layer Security is enabled in the Informatica domain.Workaround: Disable Transport Layer Security if you install the Informatica Data Services ODBC Driver 9.5.1.

305433 When you run a workflow on grid, the workflow does not perform load balancing in a Mapping task in the following scenario:- The workflow uses the exceptionLoadCount variable that the Mapping task writes as output.- The mapping runs on a worker node.

304354 When a node shuts down, some processes running on the node remain running as orphan processes.

299741 When the Domain shuts down, the catalina.out log file contains multiple messages that are not valid for the shutdown. Themessages describe conditions that cause memory leaks. You can ignore these messages.

IN_RLN_95100_0001 9

Page 10: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

297603 The task order that appears when you monitor a workflow instance differs from the task order defined in the workflow.

293234 When a service associated with a worker node terminates unexpectedly, users that subscribe to an alert message do notreceive the alert. No log message appears in Informatica Administrator.

280882 PowerCenter and Metadata Manager reports have the following issues in JasperReports Server:- The Top 10 Session with Rejected Rows (Yesterday) and Top 5 Session Error Messages reports do not provide correct

information when the data source is on a Sybase repository.- You cannot run PowerCenter dashboards when the data source is on IBM DB2 version 9.1.- You cannot launch lineage from Metadata Manager reports.

280445 If you do not perform any activity in the Administrator tool for a while, an "Unknown" message appears.Workaround: Close the message, and then the session expires.

277849 No error appears if you do not specify the required code page when you create a Data Integration Service grid.Workaround: Specify the code page.

273644 If you incorrectly install IBM DB2 client on a Windows 64-bit machine that runs Informatica Services and perform a datapreview on an IBM DB2 table, the Java Platform SE binary stops working and the Data Integration Service shuts downunexpectedly.Workaround: Reinstall IBM DB2 client correctly.

272366 The security domains do not appear when you view the assignments of a custom role.

265462 When the gateway node fails over, the PowerCenter Integration Service might not get enabled.Workaround: Set the maximum number of retry attempts for a service to start up to 10 in the Administrator tool.

267910 Test connection fails for relational connections of INFASQL type.

267051 Cannot access the Reporting and Dashboards Service after you change the node when you edit the service.

236559 infacmd CreateConnection command option values with spaces must be enclosed by single quotes on Windows and UNIX. OnUNIX, you must also enclose the command option in double quotes.

PowerCenter

PowerCenter Closed Enhancements

CR Description

311162 You can use the Design API to configure a session to read a flat file from a command with multiple partitions or a single partition.

309441 You can use the Design API to create Teradata MultiLoad connection object and to create special mask formats in a DataMasking transformation.

259944 You can use the Design API to create data masking transformation with multiple InputSet objects.

238074 You can use the Design API to rearrange the port order in a source, target, or transformation.

10 IN_RLN_95100_0001

Page 11: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

PowerCenter Fixed Limitations

Review the Release Notes of previous releases for information about previous fixed limitations.

CR Description

323627 When an SQL query returns multiple rows, the SQL transformation appends an additional character to some rows in the target.

323031 When you export reusable transformations that contain references to user-defined functions, the user-defined functions do notget exported.

319796 When you use the Design API to browse through folders in the PowerCenter repository, you cannot access a folder object if thefolder name starts with the string "Folder."

319791 Sessions that use a Microsoft SQL Server relational connection fail when you specify execute procedure as the SQL override.

319688 The pmrepagent process causes memory leaks on Windows when it runs mappings for two days.

319105 When you import a mapping that contains a mapplet with the replace objects option, the mapplet shortcut name differs.

318792 Junk characters appear at the end of the email task.

318130 When you use the Design API to create a connection to the PowerCenter repository, the connection to the PowerCenterrepository fails if you use the listconnection method directly.

317714 The PowerCenter Integration Service shuts down unexpectedly in tpordvec.h (line # 234).

316839 Value 1 of the repository query operators, Is One Of or Is Not One Of, gets deleted during the repository migration process fromWestern European to UTF-8 codepage.

316531 You cannot use the Design API to create an expression data masking transformation or standard email data maskingtransformation.

316378 Cannot deploy an object if there is a name conflict with a shortcut in the target repository.

315800 You cannot load data with multibyte characters to a column with the char datatype in an Oracle database.

315736 When you deploy the workflow with a timer task to a target folder, the subsequent deployment from the target folder fails with thefollowing REP_55035 error: TimerScheduler is not part of group.

315423 The PowerCenter Repository Service shuts down due to an unexpected condition in pmustring.cpp (line # 1615) when you runmultiple pmrep commands concurrently.

314092 After you recover a JMS topic, the source rows increment incorrectly.

313011 When you use the Design API to import SAP pool tables into the PowerCenter repository, the import fails.

312886 Session enabled for recovery shuts down unexpectedly at cachestorage.cpp (line # 1864) while writing to the recovery cache.

312845 The PowerCenter Integration Service stops responding if the PowerCenter repository connection is in a deadlock.

312835 When you use a web service client to resume a workflow that is in a suspended state, the web service client becomesunresponsive.

312703 Mapping variable values are not persisted in the repository if the repository shuts down unexpectedly when the session isrunning.

IN_RLN_95100_0001 11

Page 12: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

312691 pmrep validate does not validate the impacted sessions when the target object is deleted.

312523 Web Services Hub leaks memory when it runs batch web service operations on the Integration Service.

311828 Cannot transfer files using SFTP on Solaris 64-bit when the SFTP server port is a value other than 22.

311757 The PowerCenter Integration Service cannot load more than 65535 records in a single buffer block to an Oracle, DB2, MicrosoftSQL Server, Sybase, Informix, or MySQL database using ODBC.

311392 The PowerCenter Repository Service process shuts down due to an assert in repobjlock.cpp (line # 237).

311280 Session fails with a resource not found error when you enable the session to run on grid and you parameterize the connectionproperties.

311172 For every row that is read from an SAP HANA table, an extra row is written to the target.

311057 PowerCenter imports the SAP HANA text datatype as the ntext datatype.

311050 PowerCenter imports the SAP HANA time datatype as the decimal datatype.

310788 The source or transformation connections in a mapplet are removed when you import a session with replace option.

310728 When you copy a reusable object or replace a mapping shortcut during import, the pmrep objectimport shuts down unexpectedly.

310361 Bigint datatype converts to decimal datatype when you configure the session for pushdown to Teradata.

310239 Session hangs intermittently when it uses an SFTP connection.

310134 When there is a mismatch between the precision of a column in a Sybase source and the source definition in PowerCenter, thePowerCenter Integration Service does not load the rows that have a precision that is larger than the precision defined in thePowerCenter source definition.

310095 When you run a session with a Web Service Consumer transformation and the IgnoreResourceRequirement property in thePowerCenter Integration Service is set to No, the following error message is displayed:resource requirements [PowerExchange for Web Services]rejected [2] nodes [node names ] with memory available

309927 When you save a mapping with a Web Service Consumer transformation, the session shuts down with an unexpected conditionat loadmap.cpp (line # 7243).

308917 The PowerCenter Integration Service shuts down due to an unexpected condition in workflow.cpp (line # 1788) while recoveringan aborted workflow.

308044 With the pmrep objectimport command, the mapplet sometimes gets disconnected within a mapping.

307973 When data passes through an HTTP transformation in a Japanese locale, the http request data gets corrupted.

307822 The PowerCenter Integration Service resilience to the source database does not work when the database shuts down.

307569 Pmrep shuts down unexpectedly when you import a mapping with a mapplet.

307394 Web Services Hub shuts down unexpectedly when it receives a web service getWorkflowLog operation request that includes aworkflowrunid.

306650 The PowerCenter Integration Service shuts down unexpectedly when the post-session email attachment file is not valid.

12 IN_RLN_95100_0001

Page 13: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

306470 The repository clients hang intermittently when the PoweCenter Repository Service has a large number of connections.

306426 Mapping import fails if the mapping contains a mapplet and reusable transformation that also exists in the mapplet.

306360 When a session contains an XML Parser transformation that receives XML data from a Web Service Consumer transformation,the session fails with the following error message: XML Reader: Error [ExpectedEntityRefName] occurred while parsing:[FATAL: Error at (file EMPTY, line {line number}, char {char number}): Expected entity name forreference.]; line number [{line number}]; column number [{column number}].

305975 Sorter sessions sometimes fail with large cache size values.

305952 The PowerCenter Integration Service shuts down due to an assert in tasks.cpp (line # 127).

305599 After warm start, the session log messages from the previous session failures are missing in the current session log.

305323 HTTP transformation handles high ASCII and non-Latin characters incorrectly.

301202 You cannot use the Design API to create a nonrelational data source such as Adabas, IDMS, or Datacom with a source namethat contains a hyphen (-).

293524 REG_Replace returns incorrect value when multibyte characters are used with a NOT operator.

292362 When a locked user account sends a real-time web service request to Web Services Hub, Web Services Hub does not generatea meaningful error message.

292169 The session fails if a Microsoft SQL Server stored procedure has an input only port.

288795 If you configure substitution masking with unique output and a lookup condition, the Data Masking transformation might returnunexpected results for datetime values.

288718 If you configure expression masking for datetime values, the Data Masking transformation does not store dictionary values forrepeatable output.

288715 When you export a mapping that applies substitution masking to datetime values, you cannot apply dependent masking to shufflethe values if you remove the CONDITIONCOLUMN value.

288552 When you configure Social Insurance Number masking, you can enter start digit values that are not valid.

287875 Nonunique substitution masking fails with an exception if you select a dictionary file with fewer than five unique values.

285430 Session configured for pushdown to Teradata fails as Teradata does not support an ORDER BY clause in a subquery.

282595 Scheduled workflows do not run after a database error occurs on a repository database.

279489 Workflows without high availability recovery and scheduled to run repeatedly at a specified interval fails to reschedule if thePowerCenter Integration Service shuts down while the workflow runs.

273490 When comparing folders during deployment, a Windows dialog box incorrectly displays an error that the Repository Manager isunable to respond.

266858 Sessions that use a command to generate flat file source data does not fail when the number of reader error exceeds the errorthreshold.

260671 The Web Services Report for a secure Web Services Hub does not display correctly after a certificate is added.

IN_RLN_95100_0001 13

Page 14: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

258181 You cannot access the data lineage from PowerCenter Designer using Mozilla Firefox browser.

257503 The PowerCenter Integration Service intermittently fails or stops responding for the PowerCenter sessions that use an SFTPconnection to access a flat file source and flat file target.

242586 When the Load Balancer runs in metric-based or adaptive mode, it fails to populate the task statistics in Windows 2008.

237502 Repository performance issues occur when the repository operations access the same column in the table.

235761 The PowerCenter Repository Service on HP-UX 11.31 causes memory leaks when you perform continuous operations againstthe PowerCenter repository. Continuous operations include running workflows, importing and exporting objects, and connectingto the repository.

PowerCenter Known Limitations

CR Description

325383 The Designer cannot create mappings and displays the java.util.ConcurrentModificationException error when mapping templatesfor Visio contain multiple inputs.

324780 The Mapping Template Wizard cannot create mappings based on the slowly changing dimensions or incremental load templates.

324049 The Reporting and Dashboard Service creates new content even when the content exists under the specified connection stringwhen you choose to create new contents.

323832 Cannot create contents for the Reporting and Dashboard Service on HP-UX.

321920 The Repository Manager shuts down unexpectedly when you try to import a Microsoft Excel metadata in the Japanese locale.

317805 The session shuts down unexpectedly if you have an escape sequence in the flat file source.

311940 You cannot import a stored procedure from an SAP HANA database.

305943 The PowerCenter Integration Service creates an XML target with a different name when you use an FTP connection withoutsetting the default location.

305626 Object import fails with the pmrep objectimport command when you import the export file from the previous release for a webservice source.

304247 If datetime2 port value is NULL, then the session log displays incorrect value for the SQL transformation query.

303899 The scheduler schedules the workflow runs differently on Windows and UNIX at DST end time.

303566 Partitioned sessions using Sybase ODBC connection fails to load data to the target on z/Linux 6.1 operating system. Workaround:Use the passthrough partitioning and select the SQL Filter session property on the mapping tab.

303564 Session fails on z/Linux 6.1 operating system on loading data, when the hash-key or round-robin partitioning schemes are usedwith the Informix ODBC connection.Workaround: Use partitioning schemes other than hash-partitioning or round-robin to improve the session performance.

303436 If you select the truncate target table for DB2 target and the sessions have the DB2 native connection, then the session fails on z/Linux 6.1 operating system.

14 IN_RLN_95100_0001

Page 15: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

300497 Sendmail stops responding and remains in the same state on a SUSE Linux (64-bit) system when many workflows with the emailtask run simultaneously.

298373 A DIAG [IM003] error occurs when you use the PowerCenter Designer to query an SQL data service and the Informatica DataServices ODBC driver 9.5 is installed.Workaround: Install the Informatica Data Services OBDC Driver for PowerCenter.

294745 Performance degradation found in SQL server datetime2 in both source and target for native connectivity.

294622 When you import a shortcut object and try to replace the object, then the shortcut does not get replaced and the import fails withan error.

293288 Pmcmd commands, such as StartWorkflow, are inconsistent after you apply the infacmd disableuser and the removeusercommands.

292163 The Stored Procedure transformation returns truncated value or rejects rows when using a Microsoft SQL Server storedprocedure with datetime2 output port in a mapping.Workaround: If the datetime2 port has precision as 7 or 0 in the Microsoft SQL Server stored procedure, change the datatype ofdatetime2 port to String with precision as 29. On the Config Object tab, change the date time format of the session to the format,YYYY-MM-DD HH24:MI:SS.NS.

291772 The SQL transformation generates an error while inserting or updating datetime values in the Microsoft SQL Server.Workaround: Change the native type of the datetime port to varchar with precision as 23.

291343 Deadlock occurs on OPB_WFLOW_RUN table when a large number of workflows run concurrently.

291128 Importing the Microsoft Excel metadata for datetime2 gets converted to datetime in the PowerCenter Repository Manager.

291121 The datetime2 datatype gets converted to datetime after you export the metadata to the Microsoft Excel.Workaround: Manually change the datetime port to datetime2 in the Microsoft Excel.

290632 When the PowerCenter Integration Service is on Grid with the worker node as PowerCenter Integration Service master, and theoperating system profile is enabled, then the workflow or session recovery fails.

288780 If you use the Design API to create a BAPI transformation, you cannot partition the BAPI transformation.

283368 You cannot use the Design API to create a shortcut to a Netezza data source.

282723 Range partition is incorrectly defined for datetime2 values.

282483 The seventh fractional digit gets truncated for a datetime2 port of the target instance in the Debugger.

280683 You cannot use the Design API to fetch shortcuts from a mapplet.

280575 If you use the Design API to create a shortcut to a transformation, you cannot import the shortcut into PowerCenter.

PowerCenter Third-Party Limitations

CR Description

313061 When you load data of the text, tinytext, mediumtext, or longtext datatype to a MySQL target using the DataDirect ODBC 7.0 driver,the PowerCenter Integration Service does not load the data containing a Unicode left or right double quote character.

IN_RLN_95100_0001 15

Page 16: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

DataDirect request reference number: 00199351

313037 When you load data of the sql_variant datatype to a MySQL target using the DataDirect ODBC 7.0 driver, the PowerCenterIntegration Service does not load the data to the target.DataDirect request reference number: 00199352

273544 Cannot use self-signed SSL certificates when using the DataDirect 6.1 New SQL Server Wire Protocol driver for ODBC connectionsto a Microsoft SQL Server database.Workaround: Use an SSL certificate that is signed by a Certificate Authority.Work request reference number: W107120024

Informatica Analyst

Informatica Analyst Closed Enhancements

CR Description

290396 When you create a reference table from a file in the Analyst tool, you can exclude source data columns from the table.

Informatica Analyst Fixed Limitations

Review the Release Notes of previous releases for information about previous fixed limitations.

CR Description

310885 If you run a profile that has an address validation transformation as a rule, the Data Integration Service shuts downunexpectedly. This issue is observed in profiles that you run on flat file sources.

307644 The Analyst tool displays an error message when a mapping specification lookup returns the first row on a Sybase table thatcontains 100 columns.

306989 The audit trail does not record an operation to delete a reference table or replace reference table data in the Analyst tool.

306528 If you update data domain inference options after you run a profile to perform data domain discovery, the profile results do notreflect the changes to the inference options.

305948 If you export profile results from the Analyst tool to a Microsoft Excel file using the All option and open the file, the Excel filedisplays an error message about unreadable content in the file.

305040 The Analyst tool fails to drill down on an inferred column after you run a profile to perform data domain discovery on bothcolumn name and data with a data domain you created using a column name rule.

304552 When you perform a search and replace operation on a reference table column in the Analyst tool, the operation may fail if thecolumn name contains any lowercase character.

304831 Cannot edit a rule if a reusable rule with the same name exists in the same folder as the rule.Workaround: Either rename the reusable rule in the folder or use the Edit Rule window to select another folder as the locationfor the rule.

16 IN_RLN_95100_0001

Page 17: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

304821 The Analyst tool locks the edit tabs and cannot edit or save the rule if you apply a non-reusable rule that uses a lookup columnand then delete the lookup.

304303 The Analyst tool fails to perform the data preview for the join and displays an error on the Edit Mapping Specification dialogbox if you create a join that has the same name as a mapping specification source.

304125 The Analyst tool fails to preview the data in the lookup or target if the mapping specification uses an PowerExchange or IMSsource in a lookup.

303997 The Analyst tool fails to display the data preview on a reference table that is used as a lookup source.

303190 The Analyst tool fails to save and run a column profile after you clear all source columns during the column selection and thenclick the Save and Run button with a single selected column.

291096 When you perform a search and replace operation on a reference table in the Analyst tool, the operation fails in the followingscenario:- The table is stored in a Microsoft SQL Server database.- The replacement text is wider than the precision of any column in the table.

290896 You cannot create a reference table with a name that exceeds 30 characters in length in the Analyst tool.

277844 When you set column breaks for fixed-width flat files in the Add Flat File wizard, the alignment of column breaks may not beaccurate.

271582 If you use the Analyst tool or Developer tool to import a data object on an ODBC connection to Microsoft Excel, you cannotpreview the object properties.

258036 infacmd ps dropWH command does not remove the content on a trusted connection from the profiling warehouse.

Informatica Analyst Known Limitations

CR Description

325751 If you create a reference table in the Analyst tool from a file source that includes a decimal data column, the new reference tablewizard identifies the datatype as number. If you set incorrect precision and scale values for the column, the wizard does notprovide a clear error message.

324789 If you run several profiles and scorecards in the Analyst tool multiple times in succession, the Monitoring tab of theAdministrator tool incorrectly shows the run-time status of completed jobs as running.

324527 If you add a rule that has a data quality transformation with parameterized reference tables to a profile, the Analyst toolgenerates an error when you run the profile.

323592 If you run a profile task successfully after a failed first run, the Monitoring tab displays the task status as failed.

320268 If you run a scorecard with a renamed metric after you ran the scorecard the first time, the Analyst tool incorrectly displays azero value for the previous score of the metric.

320212 The Analyst tool may not display decimal data columns in reference tables correctly if the columns use very large precision. TheAnalyst tool may truncate the column data.

318539 When you perform reference table tasks in the Analyst tool, you cannot monitor the tasks in the Administrator tool. Thereference data tasks do not provide user name and security name data to the monitor database table.

IN_RLN_95100_0001 17

Page 18: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

314033 When you run a mapping in the Analyst tool that has reusable rules, the tool displays an incorrect number of output rows.Incorrect values appear in mappings that have output transformations with default values.Workaround: Remove the default values of the output transformation.

304818 On Internet Explorer 8, the tabs on the Edit Mapping Specification window can toggle back and forth if you click between tabsmultiple times.Workaround: Click inside a pane to stay on a tab or navigate to another tab.

290642 When you create a reference table from a profile on Oracle data, the Analyst tool does not display a warning message in thefollowing cases:- The profile data precision exceeds the precision of a reference table column.- The operation adds decimal data to a column defined for Integer datatypes.

280325 Exporting value frequency data after drilldown raises an error if the locale setting of the internet browser is Simple Chinese andthe export file name contains UTF characters.

287158 If you cancel the filter preview on a profile, the Analyst tool does not correctly update the job status of the filter preview.

279651 If you run a profile on an Oracle data source that has a number without precision and scale, the profile results display thenumber in the scientific format.

235819 If you run a profile with a reusable rule in the Analyst tool and later change the rule name and rerun the profile, the Analyst tooldoes not display the new name.

Informatica Data Transformation

Informatica Data Transformation Fixed Limitations

Review the Release Notes of previous releases for information about previous fixed limitations.

CR Description

CM-5886 When you install Data Transformation Server on a 64-bit Windows machine in a directory other than the default installation directory,Data Transformation does not run.

CM-5860 You can enter any valid QName while specifying a fault code to generate a fault in a web service. A Web Service Consumertransformation returns a value with the alias used in the SOAP response.

Informatica Data Transformation Known Limitations

CR Description

311610 You cannot connect more than one Data Transformation Streamer to a Complex file reader when you push a mapping to Hadoop.

303300 When you install Data Transformation with Informatica Services, some Data Transformation startup components appear in theWindows Program Menu. If you click a Data Transformation component from the menu, an error appears that CMConfig.xml is notvalid.Workaround: Run Data Transformation components from the <Installation_Directory>\bin directory.

18 IN_RLN_95100_0001

Page 19: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

288495 When an Option statement fails in an XMap, the details about the failure appear under the Router node in the Events navigation treeinstead of under the RouterOption node.

CM-5805 The Data Transformation Engine does not accept schemas that contain XSD pattern retrictions based on Unicode general categoriessuch as p{L], p{N}.Workaround: Modify the .XSD file that contains the unsupported pattern restriction, or update the RegexReplacements.tgp file in thefollowing folder: <Installation_Directory>\DT\autoinclude\system

CM-5722 The XMLStreamer component does not process the trailer part of an input message.Workaround: Use another component to process the trailer.

CM-5549 The WordToDataXml document processor does not process text that appears after an endnote.

CM-5515 When you import a project with a schema that contains both an <xsd:include> and an <xsd:redefine> element, the project cannot beexported and the following error appears:Invalid XSD error: '<file_name>' has already been included or redefinedWorkaround: Remove the <xsd:redefine> element from the schema.

Informatica Data Quality

Informatica Data Quality Closed Enhancements

CR Description

307316 A non-valid identity population file in the specified population directory does not prevent the Content Management Service fromreading valid population files. If the service encounters a file that is not valid, the service writes an error message to the ContentManagement Service logs.

280553 When you delete a probabilistic or classifier model from a content set, the operation also deletes the model file from theinstallation directory.

Informatica Data Quality Fixed Limitations

Review the Release Notes of previous releases for information about previous fixed limitations.

CR Description

312686 The usa_states reference data file in the United States and Canada accelerator pack does not contain complete state names.

310869 You cannot run a mapping that contains a reusable Address Validation, Association, or Consolidation transformation inPowerCenter if the transformation uses parameters.

310319 Identity match analysis in Informatica Data Quality and Informatica Identity Resolution applications can generate different matchscores given the same input and population data.

306779 If you run a mapping in PowerCenter that searches for duplicate identities, PowerCenter does not assign duplicate records tothe same cluster. PowerCenter creates a cluster for each record in the input data.

IN_RLN_95100_0001 19

Page 20: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

306759 A Human task fails to run on SUSE Linux 11 64-bit systems and Red Hat 6.1 32-bit systems.

306410 You cannot create a reference table with the same name as a deleted reference table. The table name remains in the registrytable after you delete the object from the Model repository and delete the table from the reference database.

305824 The process to export an address validation mapping to PowerCenter generates errors in the following scenario:- The Address Validator transformation specifies more than one execution instance.- The Address Validator transformation uses one or more ports from the U.S. Specific group, and any port name exceeds 80

characters in length.

305612 When you correct exceptions in Informatica Data Director for Data Quality, the Replace All option does not replace all specifiedvalues in the task data.

305393 A mapping that includes a Match transformation fails in PowerCenter on a zLinux SUSE system.

304361 If you attempt to rename a reference table that contains integer or bigint datatypes, the rename operation fails.

288683 An error occurs when the length of the reference table column name is longer than the limits set by the database.Workaround: Reduce the length of the column name when you create the reference table.

287992 The Data Integration Services can consume excessive memory and stop unexpectedly when you run multiple consecutiveaddress validation mappings.Workaround: Review the preload settings on the Content Management Service and verify that the settings do not require morememory than the system can provide. Restart the Content Management Service and the Data Integration Service if you edit thesettings.

Informatica Data Quality Known Limitations

CR Description

324161 When a workflow assigns a very large number of tasks to a user, such as 10,000 tasks, Informatica Data Director for DataQuality takes a long time to display the list of tasks.

324152 Search operations fail on an unmanaged reference table if the reference data columns include a primary key column. In theDeveloper tool, the search operation returns incorrect data. In the Analyst tool, the search operation returns no data.

323652 You cannot create an unmanaged reference table from an IBM DB2 or Oracle database source if the source table is not part ofthe default schema.

323383 A mapping that performs identity match analysis may fail to run on grid if you configure the grid Data Integration Service afterthe master Content Management Service on the domain.

321649 A Human task does not recognize security domain information when it distributes task instances to users. If you use a list ofuser names to distribute Human task instances by value, the process handles the user names in the following way:- The process ignores any user name that identifies a security domain.- The process selects the first occurrence of a user name that it finds in the Informatica domain.

320831 You can create a reference table column of datatype varchar with a scale of 4,000 characters. You cannot edit a value in thecolumn if the edit creates a value with more than 2,000 characters.

320388 When you add a date value to a reference table column of datatype date, the column is updated with time values in addition todate values.

20 IN_RLN_95100_0001

Page 21: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

319787 You cannot perform an operation to complete all task instances associated with a Human task if the tasks were created in anearlier version of Informatica Data Quality. If you created a workflow with a Human task in an earlier version of Informatica DataQuality, verify that the workflow is completed before you upgrade.

319554 When you run a mapping with a Classifier transformation out of process, the mapping may fail due to excessive demands onmemory. The memory required depends on the number and size of the classifier models you add to the Classifier transformation.Work around: increase the Java memory allocation on the Data Integration Service. Create a JVMOption custom property on theservice and set the memory on the property, for example JVMOption1 = -Xmx640M.

265573 If you run a session with a mapping that uses an Exception transformation to write duplicate record data to an Oracle database,you experience problems when you consolidate or extract records in a duplicate record cluster. The Analyst tool identifies everyrecord in the cluster as a master record.

Informatica Developer

Informatica Developer Closed Enhancements

CR Description

313701 The Developer tool client installer file includes a silent installer for the JDBC/ODBC driver.

304725 You can use the Developer tool edit the precision of a reference table column that stores row-level descriptions.

271309 The Developer tool takes less time to connect to a remote Model Repository Service running on a Wide Area Network (WAN).

270578 The Developer tool displays the current run-time status of a profile in the Results view if you open the profile in another clientmachine.

264235 Within a logical data object model, you can copy a source created from a logical data object from one logical data object readmapping to another read mapping without copying the entire model.

236108 The Decision transformation handles the ISNULL function in the same manner as the Expression transformation.

Informatica Developer Fixed Limitations

Review the Release Notes of previous releases for information about previous fixed limitations.

CR Description

321878 When you use a Japanese population file in identity match analysis on two data sources, the analysis adds space characters tothe shorter record in a manner that causes the match score to increase.

319365 When you a run a profile on a mapping or mapping object that has a Match or Router transformation with multiple output groups,the Developer tool generates an error.

314159 When you run a mapping with a Consolidation transformation in a Japanese locale, the transformation creates a redundant outputport and causes the Data Integration Service to stop abruptly.

313014 The Developer tool imports the SAP HANA smalldecimal datatype as the varchar datatype.

IN_RLN_95100_0001 21

Page 22: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

312995 The Developer tool imports the SAP HANA text datatype as the ntext datatype.

312993 The Developer tool imports the SAP HANA smalldecimal datatype as the varchar datatype.

312787 After you restore the profiling warehouse, a SELECT statement on the IDPV_BOTTOM_10_FREQUENCIES profile view does notrespond for a long period of time.

311628 A web service cannot apply a keep alive interval if the service contains a mapping that uses a Decision transformation.

311384 When you create a logical data object from an existing schema file and export it to PowerCenter, the export fails. The exportprocess defines the output ports of the object as Null.

310869 You cannot run a mapping that contains a reusable Address Validation, Association, or Consolidation transformation inPowerCenter if the transformation uses parameters.

310392 If the search results in the Developer tool return more than 2048 objects, search fails with the following error: MRSI_40042"maxClauseCount is set to 2048".

308113 You can configure an Association transformation so that an input and output port define different datatypes for a single column ofdata.

306976 A Mapping task in a workflow fails if the mapping includes a reusable transformation.

306762 The Developer tool requires that users have write access to the installation directory because the tool creates a target/ics-workspace directory within the installation directory.

306429 You cannot create a WSDL data object using SOAP 1.2 WSDL when the SOAP binding element is not the first element under theWSDL binding element.

306339 You cannot preview data on a Java transformation after you preview data on a Parser transformation in the same mapping if youconfigured the Parser transformation for probabilistic analysis.

306205 The Data Integration Service hangs when it tries to refresh cache for logical data objects that contain a primary key with noattribute defined.

305443 When you manually map nodes to ports in a Web Service Consumer transformation, the Developer tool uses the default precisionport value instead of the value defined in the WSDL.

305409 When you copy an object to a logical data object mapping that contains a circular reference due to primary and foreign keys of thelogical data objects, the copy process fails with a Java Heap memory error.

305391 When an operation mapping contains a large number of ports, the Developer tool shuts down unexpectedly when you view orconfigure objects in the mapping.

305363 When you configure a strategy in a Consolidation transformation and save and close the transformation, the strategy option iscleared.

305296 The Developer tool does not display a warning message when you add or edit a label in a probabilistic model file.

305211 When you create and compile a probabilistic model in a content set, the content set does not display the compiled status of theprobabilistic model.

305201 If you close a profile and open it again after you verify the data domain discovery results in enterprise discovery results, thecolumn profile results do not appear.

22 IN_RLN_95100_0001

Page 23: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

The profile model results summary displays only the latest results and does not display the results for all columns from multipleprofile runs if the following conditions are true:- You run the profile again within the profile model after the first profile run.- You run the profile the second time with the same configuration options that you used for the first profile run.- You run the profile the second time on a different set of source columns.

305090 Workflow deployment fails when the workflow contains two mappings with the same name from different projects.

305080 If you assign the Working Directory configuration property to task input for a Command task, the Advanced view displays an emptyvalue for the property.

305040 The Developer tool fails to drill down on an inferred column after you run a profile to perform data domain discovery on bothcolumn name and data with a data domain you created using a column name rule.

304740 When you create a reference table from a relational data source and add a column for row descriptions, the column precisionchanges when you open the table in the Analyst tool or export the table from the Model repository.

304571 The Developer tool generates an error when you run a join profile if the following conditions are true:1. Create a join profile on multiple data objects in the profile model.2. Specify a self join condition on columns in one of the data objects.3. Save and run the profile.4. Add another join condition across multiple data objects.5. Save and run the profile.

304361 If you attempt to rename a reference table that contains integer or bigint datatypes immediately after you create or edit the table,the rename operation fails.

304206 A Mapping task runs successfully when the user who started the workflow instance does not have execute permission on theconnection used by the mapping.

304122 You can enter any valid QName while specifying a fault code to generate a fault in a web service. A Web Service Consumertransformation returns a value with the alias used in the SOAP response.

303976 An Assignment task cannot assign a date earlier than 1970 to a date workflow variable.

303883 The Developer tool generates an error when you view the connection attribute in the foreign key results after you run enterprisediscovery on SAP and PWX non-relational data sources.

303510 When you export a mapping that contains a Labeler or Parser transformation for use in PowerCenter, the export process does notexport any probabilistic model file read by the transformation.

301689 You cannot use a probabilistic model if you do not have Read permission on the Content Management Service.

301664 Mappings that contain Source Qualifier transformations with the following conditions fail to import from PowerCenter:- Any column name contains a hyphen.- Any column name does not match the source column name.- Any extra columns that do not exist in the source table.

301361 The Labeler transformation may rename the overflow port on a labeling strategy with the overflow label from a probabilistic modelsaved to the strategy.

300290 Import from PowerCenter process fails to import objects with datetime datatype in repositories that were upgraded fromPowerCenter versions prior to 8.5.

299242 A Notification task fails and does not send email to any recipient when one of the recipients does not exist in the Informaticadomain.

IN_RLN_95100_0001 23

Page 24: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

299142 When you propagate attributes to a Joiner transformation, the Developer tool allows duplicate port names for master and detailports.

297561 When you run a mapping that reads a reference table, the mapping generates an error if the reference table contains integer datafrom a from a relational data source.

296881 When a mapping for a logical data object model contains a reusable logical data object Lookup transformation that uses a logicaldata object from the same model, the mapping links between the Lookup transformation and a downstream transformation will bedeleted the next time you open the repository.

296758 The Developer tool stops responding when you redeploy an application to more than three Data Integration Services and youchoose the update option.

296734 If you export an object to PowerCenter that contains dependent object instances from another project, and you do not have readpermission on the other project, the Developer tool does not create the export file.

296664 If you create a Data Masking transformation with key masking on the input string port and enter the seed value as 100, then theoutput does not have unique values.

295487 Microsoft SQL Server sources with a datetime2 datatype fail to import from PowerCenter.

295030 You cannot create user-defined parameters in reusable Aggregator, Joiner, Rank, and Sorter transformations.

294832 If you import a profile after you export it along with data domain glossary, the Developer tool does not import the data domains.

294088 When you import a Source Qualifier transformation from PowerCenter, the import process does not preserve the tracing level forthe Source Qualifier transformation.

289383 The Overview tab on a reference table does not list column names or options to update the columns.

288968 When you view the column relationships after enterprise discovery, the Developer tool does not display the order of the primarykey and foreign key relationships accurately if the following conditions are true:1. You run enterprise discovery for a few data objects.2. You import another data object and add to the model.3. Open the foreign key profile task and add the imported data object to the task.4. Run the foreign key profile task and open it to view the column relationships.

285649 The Data Integration Service experiences memory leaks and stops unexpectedly when a web service operation mappingencounters a fault.

283100 On UNIX, the infacmd oie ImportObjects command fails when the user does not have write permission on the $INFA_HOME/isp/bin directory.

281633 If you edit the default overflow column name in a probabilistic model and add the probabilistic model to a Parser transformation,the transformation creates additional output ports.

271430 If you create a Consolidation transformation in an earlier version of Data Quality and upgrade to Data Quality 9.1.0 HotFix 2, thecache size setting for the transformation changes to 0 bytes.

269222 Infacmd oie commands that export and import objects do not generate valid messages when you fail to specify source or targetprojects.

265546 The Developer tool displays an error that it cannot connect to the repository when you save a mapping after you copy a logicaldata object read, write, or Lookup transformation that is associated with a relational data object into its own logical data objectread mapping.

24 IN_RLN_95100_0001

Page 25: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

261680 Importing a mapping with an unmanaged reference table does not report an error if no connection exists for the reference tabledatabase.

259879 When you import a WSDL to create a WSDL data object, the entire validation message does not appear in the Select a WSDLdialog box.

258133 The load time for the Match transformation Analysis view increases significantly if the advanced profiling property Maximum #Value Frequency Pairs is set to a large number such as 1,600,000.

239928 You cannot set the cache size for sorting operations in the Key Generator transformation.

Informatica Developer Known Limitations

CR Description

326108 If you run a mapping with a Match transformation that you configured for identity analysis, the mapping runs more slowly if youselected the Filter Exact Match option in the Match transformation.

325647 When you run data domain discovery on a data source with a data domain that has a rule with a non-String input port type, datadomain inference fails for source column datatypes that do not match the input port type of the rule.Workaround: Change the input port type of the rule to String.

325486 When you run a mapping in a Hive environment that uses the SYSDATE variable, the output can be empty with no rows in thetarget.Workaround: You can use the function SYSTIMESTAMP('SS').

325435 When the Data Integration Service writes a log message for an address validation mapping, the message omits the versionnumber of the Address Doctor engine.Workaround for an address validation mapping in the Developer tool:1. Open the Developer tool and select Window > Preferences> Informatica > Run Configurations.2. Select Data Viewer > Advanced, and set the Override Tracing Level option for the Data Viewer to Verbose Data.3. Select Mapping > Advanced, and set the Override Tracing Level option for the Data Viewer to Verbose Data.4. Click OK.Workaround for an address validation mapping you deploy in an application:1. Open the Administrator tool and select the Data Integration Service that runs the application.2. Under Applications, expand the application that contains the mapping.3. Open the mapping properties and set the tracing level to Verbose Data.4. Click OK.

325243 You cannot specify a reference data file for import when you import an Informatica application archive file.

325026 An Exception transformation cannot write data to a Microsoft SQL Server database if the JDBC connection string for thedatabase includes the name instance for the database and the TCP/IP port number.Work around: use the name instance or the TCP/IP port number in the connection string.

324891 If you select a data source that is not valid in the new reference table wizard, you must exit the wizard. The issue occurs if youselect a data source with column names that include unsupported characters. The Developer tool displays an error messagethat identifies the file.

324752 The Labeler transformation does not recognize decimal datatypes in a reference table. The transformation treats decimaldatatype values as strings.

IN_RLN_95100_0001 25

Page 26: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

324743 The Developer tool and Analyst tool cannot correctly display a reference table that you create from a data source of floatdatatype values. The reference table columns appear with truncated scale values.

324527 If you run a profile on a mapping object or mapplet object or add a rule to the profile, the Developer tool generates a run-timeerror for a rule that has a data quality transformation with parameterized reference tables.

324516 You can validate either parent-to-child or child-to-parent relationship in the foreign key results between two primary keys but notboth.

324434 The Developer tool might encounter a null pointer exception when you attempt to delete a folder that contains objects that arecurrently being moved by other users.

324240 The Developer tool fails to run the profile if the following conditions are true:- You run foreign key discovery on a Twitter streaming connection.- You run primary key and foreign key discovery on a Kapow connection.- You run foreign key discovery on a DataSift streaming connection.

324105 When you run profile jobs or scorecards and disable the Data Integration Service with the Abort option, the Analyst toolincorrectly displays the status of profile jobs as canceled instead of aborted.

324156 The import fails for PowerCenter mappings that contain a source or target with a port of a Char datatype and a precision of 255for the following relational objects:- IBM DB2zOS source and target- IBM DB2i5OS source and target

324095 When you discover foreign keys of objects that have user-defined keys without selecting a primary key, the Developer toolgenerates an error.Workaround: Run primary key discovery along with foreign key discovery.

323971 infacmd ps createWH and dropWH commands on a client machine do not run successfully on a trusted connection from theprofiling warehouse.Workaround: Use the Administrator tool or server to create or drop the profiling warehouse database content.

323525 When you import a mapping and a mapplet with the same name from PowerCenter, the import process fails to resolve theconflict with the identical names.

322890 The Connection Explorer does not show the default schema for a Microsoft SQL Server connection that uses a trustedconnection.

322734 If you rename a content set and then undo the operation, the Developer tool generates a null pointer exception.

322033 You cannot create a probabilistic model from a data object if the Developer tool runs in a Japanese locale.

321884 You cannot create a probabilistic model from a data object if the Developer tool runs in a Korean locale.

320832 You cannot import a table containing the \ character in the table name using the DataDirect SQL Server ODBC drivers.

320811 When you export entity results after you run enterprise discovery on more than a thousand relational data sources with a largenumber of data object relationships, you may get a Java Heap memory error.

319860 The Developer tool might encounter a null pointer exception if you select and drag multiple output ports from an AddressValidator transformation to another transformation in a mapping.

319958 If you search a reference table for a data value and you edit a reference table cell during the search operation, the operationrestarts from the first row of the reference table.

26 IN_RLN_95100_0001

Page 27: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

319471 If you add an output port to an Address Validator transformation after you run the Data Viewer on the transformation, the portdata appears in the wrong column when you next run the Data Viewer.

319026 An Address Validator transformation that you configured in fast completion mode does not correctly validate an address whenthe house number begins with a zero.

318971 If you create a reference table from a Sybase IQ ODBC database in the Developer tool, some or all data cannot be written to thereference table. The issue arises because the Sybase database permits larger precision values than the reference tabledatabase for some datatypes.

317957 When you run a column profile in the Hive environment, patterns for decimals may not consider trailing zero values resulting intruncated pattern characters.

317180 A mapping fails to run with an exception error in a Hive environment when the Hive mapping connection and the Hive source ortarget connection connect to different Hive metastores.Workaround: When you run a mapping in a Hive environment, the Hive connection selected for the Hive source or target, andthe mapping must access the same Hive metastore.

316501 If the Service Manager is under a heavy load, it might not renew user authentication tokens before the expiration time. As aresult, you might encounter a user session expired error when you connect to the Model Repository Service from the Developertool or when you deploy an application to the Data Integration Service using the Developer tool or Administrator tool.Workaround: Recycle the Model Repository Service and then the Data Integration Service. Then, restart the Developer tool orlog out and then log back in to the Administrator tool.

314772 If you use port names that include punctuation or control characters in an expression, you might encounter the following errorwhen you run a mapping, preview data, or preview web service messages: "Problem communicating with DIS service."Workaround: Modify the port names so that they do not include punctuation or control characters.

313012 The Developer tool imports the SAP HANA date, time, seconddate, and timestamp datatypes as the varchar datatype.Workaround: Manually change the date, seconddate, and timestamp datatypes to timestamp. Change the time datatype tovarchar.

312563 If you compile a classifier model and the compilation process consumes the available memory, the Developer tool does notdisplay an error. The memory is set on the Content Management Service, and the service writes an out of memory error to thelog.

304571 The Developer tool generates an error when you run a join profile if the following conditions are true:1. Create a join profile on multiple data objects in the profile model.2. Specify a self join condition on columns in one of the data objects.3. Save and run the profile.4. Add another join condition across multiple data objects.5. Save and run the profile.

303208 If you install the Developer tool but not the PowerCenter Client, the installation process does not create the substitution storagescripts that you need to create the substitution storage table in the storage connection.To create the substitution storage table for repeatable substitution masking, contact Informatica Global Customer Support.

300988 If data domain discovery on a flat file source fails, the Developer tool displays results from the last successful run.

300267 Data Integration Service mapping logs do not include parameter information.

296282 When you configure a Human task to divide tasks by data value, the task configuration pane displays data values of type stringwith a precision of 20 or less. Data values of other datatypes or other precisions are not shown.

IN_RLN_95100_0001 27

Page 28: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

294942 If you run both overlap profile and foreign key profile on a data source with all column datatypes that are not supported, theDeveloper tool generates an error.

292100 An Assignment task cannot assign the minimum integer value (-2147483648) to an integer workflow variable.

291969 A web service mapping fails with an XPath error when you create a Web Service transformation and a group name or a fieldname contains characters that are not valid in an NCName element type. An NCName type is a name that is not qualified by anamespace.Workaround: Remove characters from the group and field names that are not valid in an NCName type.

291759 When you run a profile model with a few data sources, the Data Integration Service log file does not correctly display the dateand time format and run-time status of the profile model.

286556 If you run a profile on a data source that has datetime columns, the format of date and time values in exported drill-down resultsdoes not match the format of column profile drill-down results for datetime columns.

284846 The Char or Varchar precision of a column is four times the actual precision when the following conditions are true:- You use Char semantics to define the column size of a column of the Char or Varchar2 datatype.- The NLS_CHARACTERSET is set to AL32UTF8.- The schema name contains no special characters.

282600 When you create a probabilistic model from a data source, the probabilistic model adds space and tab delimiters to the set ofdelimiters you select. This issue is observed when you clear the space and tab delimiter options.

279651 If you run a profile on an Oracle data source that has a number without precision and scale, the profile results display thenumber in the scientific format.

276266 When you delete a project that other users are working in, the Developer tool does not display a warning message to alert youthat other users are working in the project.

272653 When you use an ODBC connection to connect to an Excel file, preview fails with the following error message:[LDTMCMN_0029] Error reading from the stream because of the following message: [The operation did not run correctly because of the following error: [RR_4035 SQL Error [FnName: Prepare -- [Microsoft][ODBC Excel Driver] Syntax error (missing operator) in query expression.Workaround: Create a relational data object for the Excel file, and then preview the relational data object.

272479 When you include single-level and nested functions in the same Aggregator transformation, the Developer tool does not markthe mapping or mapplet as not valid. When you run the mapping, the Data Integration Service fails the mapping with a validationerror.

272096 The Family strategy for identity matching in the Match transformation does not identify the Address Part 1 and TelephoneNumber secondary inputs as required secondary inputs.

271633 When you map a Web Service Consumer Transformation input port as XML, the Developer tool does not map a location for theKey_Request node. The mapping fails with the following message in the run-time log:[[ERROR] XML generator component [Cookie0_R2H_Input] message code: [66046], message body: No fields are mapped for location [/infasoapns:Envelope] in group [RequestInput]. Map the ports from the input group to the nodes in the hierarchy group.].]Workaround: Complete the following steps:1. Delete the link between the Web Service Consumer Transformation input port and the Request node in the operation input.2. Map an input port to the Key_Request node.3. Right-click an input port and choose the option to map as XML.

270493 Cannot connect to a web service if you specify localhost in the endpoint URL used by a Web Service Consumer transformation.Workaround: Specify the host name or the IP address instead of localhost in the endpoint URL.

28 IN_RLN_95100_0001

Page 29: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

270098 If you configure a mapping with an Oracle data source and a Match transformation set to run in identity matching mode, and youchange the data type on a source column that you connect to the Match transformation, you cannot preview the data on thetransformation.

269721 If you change a column datatype from String to Integer in a flat file data source and run a profile on the data source after you runthe profile in Informatica Analyst, you may get a run-time error about an incorrect value for the Aggregate function.

262249 The Labeler transformation incorrectly updates label overrides for character sets when the following conditions occur:1. You add multiple character sets with label overrides to a Labeler transformation2. You delete one of the character sets from the parent content set3. You disconnect and reconnect to the Model repository

258847 Mapping hangs on Solaris and the Data Integration Service shuts down unexpectedly if you enable Truncate Target Table for aTeradata target.

258708 The primary key and functional dependency inference results on columns with null values may vary depending on whether youjust run the profile or validate the profile results. This variance occurs because inference is based on the summary of null valueswhereas validation displays all the records.

258707 If you apply an active filter to a profile after you run the profile without any filters, the drilldown results may not be accurate.Workaround: After you set the active filter, run the profile again before you drill down on a column.

257609 Mappings that contain a logical data object cannot be exported to PowerCenter if the logical data object uses a physical dataobject as a source and the logical data object also contains a customized data object that is created from the physical dataobject.

256315 Mapping with a Web Service Consumer transformation returns an incorrect error message when it processes data of a date/timedatatype with min/max facets.

255827 When you preview a relational data object, the session load summary in the log file does not list the rows rejected while readingdata from the database as rejected rows.

255089 When the Data Integration Service filters or performs a lookup on char datatypes, the Data Integration Service uses varcharsemantics and therefore it does not ignore trailing spaces for the following types of mappings:- A mapping with a relational Lookup transformation- A mapping that is not optimized and includes a logical data object Lookup transformation- A mapping that is optimized and includes a logical data object Lookup transformation that contains a relational read mapping

without a pipeline- A mapping with filter transformation logic that cannot be pushed down to the source

254167 A Data Integration Service proxy server that uses HTTP 1.0 returns an error if the HTTP server and client use HTTP 1.1 and theSOAP request size is greater than 1024 bytes.Workaround: Use HTTP 1.1 for the proxy server.

254009 For a functional dependency inference with a set confidence threshold, a non-primary key column cannot determine a primarykey column.

249655 The logical data object Lookup transformation does not return a match for a NULL input value when the lookup source containsa NULL value.

237792 If you delete a reference table object from a project folder in the Developer tool or Analyst Tool, the reference table data remainsin the staging database.

235924 The Developer tool can specify a reference table as a parameter. It reads the parameter setting from a different tab dependingon whether you run the mapping or run a profile on the mapping.When you run the mapping, the Developer tool looks for the parameter on the Parameters tab. When you profile output from amapping object, the Developer tool looks for the parameter on the Configuration tab.

IN_RLN_95100_0001 29

Page 30: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

234898 If you enter a custom SQL query that contains a DDL statement in a customized data object, the Developer tool might executethe query against the database when you validate the query.

234419 Because the Developer tool does not retain key field information for nonrelational data sources, you cannot include an UpdateStrategy transformation in a Developer tool mapping for a nonrelational data source.

224728 You cannot run a mapping that uses two Match transformations in parallel when both transformations are set to identity matchmode.Workaround: Configure the mapping to run the Match transformations serially.

224341 If you run a mapping that writes data to a Microsoft SQL Server resource using the ODBC driver for Microsoft SQL Server, theData Integration Service rejects all records that contain data of type hierarchyid.Workaround: Use the native Microsoft SQL Server driver instead of the ODBC driver.

222982 Bulk loading fails when you run a mapping that loads long varchar for bit data to an IBM DB2 database and the database serverversion is 9.1, the database client version is 9.5, and the Data Integration Service runs on 64-bit SUSE Linux.

215419 Mapping generates a core file on Solaris 64-bit if you enable Truncate Target Table for an IBM DB2 9.5.x target and you set thenumber of rows you want to preview to 0.

Informatica Developer Third-Party Limitations

CR Description

319703 When you import a relational data object for an Oracle database using the DataDirect Oracle driver, the column width is importedincorrectly for some versions of the Oracle database.DataDirect request reference number: 00201017

313588 When you preview data for an SAP HANA source, for every source row, an extra null row appears. When you run a mapping, forevery source row, an extra null row is written to the target.SAP request reference number: 779024/2012

313060 When you load data of the text, tinytext, mediumtext, or longtext datatype to a MySQL target using the DataDirect ODBC 7.0 driver,the Data Integration Service does not load the data containing a Unicode left or right double quote character.DataDirect request reference number: 00199351

299298 The Data Integration Service crashes when you run mappings concurrently using an SQL Server ODBC connection and theDataDirect SQL Server ODBC 7.0 driver.DataDirect request reference number: 00199353

292872 When you import a table with an XML datatype using the DataDirect JDBC 5.0 driver, the precision is set to 0.DataDirect request reference number: 00168257

30 IN_RLN_95100_0001

Page 31: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

Metadata Manager

Metadata Manager Fixed Limitations

Review the Release Notes of previous releases for information about previous fixed limitations.

CR Description

318324 You cannot load a PowerCenter resource if the resource contains recursive worklets.

313415 Users with read permission on a business glossary object can use the Object Relationships Wizard to create or modifyrelationships for the object.

312579 The Custom Metadata Configurator client application does not display vertical scroll bars. Therefore, when many templates areconfigured, you might not be able to view them all.

309484 If you export two custom models with related classes to one XML file and then try to import the XML file, import fails.

309126 When you export the lineage diagram for an object with a name that does not contain spaces to Microsoft Excel and open theExcel document, Excel displays an error message saying that the file has unreadable content. If you open the document, the linksin the Excel file do not work.

309120 When you export a very large data lineage diagram to Microsoft Excel, or you export lineage for an object with a name thatcontains spaces to Excel, the export operation might fail with an exception.

305001 While linking, the audit trail for attribute values is also considered by the selection expression while filtering the objects.

304945 The full object name does not appear in the catalog tree if the object name contains angle brackets.

303273 When you run load multiple resources simultaneously, the load sometimes fails while running an ETL task.

300200 You cannot use a resource configuration file that does not have any connection assignments with the updateResource mmcmdcommand to remove the connection assignments for the resource.

299777 When you export and reimport a business glossary, you cannot propose a business term. Metadata Manager displays a messagesaying that no data steward is assigned, even though a data steward is assigned.

298764 Data lineage diagrams take a long time to generate.

297377 Expressions in an Oracle Business Intelligence resource are not properly parsed and do not appear in the lineage.

284701 Data lineage diagrams do not display all upstream and downstream dependencies for a Teradata macro.

283718 Data lineage diagrams do not display all upstream and downstream dependencies for a Teradata macro.

277444 Data lineage diagrams might not display parameterized file names in PowerCenter mappings correctly.

249136 When you hover over a label for a property in the Business Glossary, and the definition for the label is a long string, the textappears to be truncated.

IN_RLN_95100_0001 31

Page 32: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

Metadata Manager Known Limitations

CR Description

325617 You might not be able to load an Informatica Platform resource that contains multiple Expression transformations with the sameexpression text.Workaround: Set the following property in imm.properties and then restart the Metadata Manager Service:xconnect.io.ime.validation.skip=true

325444 You cannot use the mmcmd createRepository command to create the Metadata Manager warehouse in a named Microsoft SQLServer instance.Workaround: Use the Administrator tool to create the Metadata Manager warehouse.

325075 When you reload an OBIEE resource when the source is unchanged, the Load Details Objects view displays the values for thepreload object count, objects added, objects deleted, objects updated, and total objects as the same number for some objecttypes.

324894 Metadata Manager throws an exception when you create a custom object, rename the object, and create another custom objectwith the same name.

324164 Metadata Manager does not display the impact summary for instances of mapplet shortcuts.

323619 When you run Metadata Manager on Firefox, and you create a custom resource, Metadata Manager sometimes does not allowyou to select the last mapping rule in the Mapping Rules list.

322982 Business terms related to Power Center reusable objects appear multiple times in the data lineage diagram.Workaround: Refresh the data lineage diagram.

322816 When you export a custom resource that contains enumerated links with expressions, purge the resource, and then reimport theresource, the imported resource does not contain the expressions in the lineage diagram.

322383 When you view properties for objects in Informatica Platform resources, Metadata Manager does not display the date the objectwas created in the source system or the date the object was last updated in the source system.

322098 The metadata catalog and data lineage diagrams do not display group-level information for transformations in InformaticaPlatform resources that have multiple groups.

321192 Data lineage diagrams for Informatica Platform resources do not display related instances lineage for reusable transformations.

319226 Metadata Manager does not always display the "from object" and "to object" names in relationships for ERwin resources, so theBrowse navigator might display multiple relationships with the same name. When you select a view relationship in the RelatedCatalog Objects area, Metadata Manager might display the wrong relationship.

316072 When you import a very large custom resource that you previously exported, Metadata Manager might hang if the load on theMetadata Manager warehouse is very high.

314084 When you load a Teradata resource, the Sessions tab of the load log might display a few write errors in PowerCenter sessionS_M_FEATURE_MAP_FIRST_LOAD. The errors do not cause metadata loss.

322588 Searching for a business glossary does not work if you modify the index location in bg.properties and restart Metadata Manager.Workaround: Log in as an administrator to the Metadata Manager Business Glossary and index the business glossary again.

322781 The Business Glossary Desktop installer does not display the LDAP security domain and displays an error for LDAP users whoselect the Native security domain.Workaround: Ignore the error and continue with the installation. After you install the Business Glossary Desktop, configure theLDAP security domain in the server settings.

32 IN_RLN_95100_0001

Page 33: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

304978 When you reload an SAP R/3 resource after you upgrade from 9.1.0 HotFIx 3 to 9.5.0, all SAP application components andpackages are deleted and reloaded. Any customization to the resource is lost.

304602 Parameter files are not parsed correctly for a PowerCenter resource with nested worklets if you specify the session parametervalue in the workflow and in multiple nested worklets, and the session scope in the parameter file.

303897 Metadata Manager Service takes a long time to shut down and causes memory leaks.

303420 When you simultaneously create the link between two resources that have a connection assignment with each other, the statusof both the resources appears as Linking Successful;Some Linking Deferred.Workaround: Create the links for the resources again.

301722 When you load a Microsoft Analysis and Reporting Services resource, unique constraint errors occur.

301610 Loading fails if you reload a Microstrategy resource after you cancelled the previous load, and incremental extract is enabled.Workaround: Disable incremental extraction and reload the resource.

298429 When you load multiple resources simultaneously, object path building sometimes fails because of unique constraints.Workaround: Reduce the number of parallel loads or reload the individual resources for which object path building failed.

296033 For a Business Objects resource, the Web Intelligence, Desktop Intelligence, and Crystal report classes appear in the samelevel as the ObjectPackage class in the catalog tree. In addition, if the objects have the same name, Metadata Managerappends a numerical suffix to the name.

295349 An error occurs when you import metadata from a custom model XML file in which the XML elements are not in the properimport order.Workaround: Generate the XML to ensure that the parent elements are imported before the child elements.

288675 For an ERwin resource, Metadata Manager Agents extracts all view relationships with the ViewRelationship class name insteadof using the class name specified in the source system.

285476 For a Business Objects resource, Metadata Manager does not merge the Business Objects folder and class objects in thecatalog tree.

282509 For an Oracle Business Intelligence resource, expression values extracted by the Metadata Manager Agent are not similar to theexpression values in the source system.

273665 The backupconfiguration command does not back up the schedules associated with resources and does not back up the refreshoption specified for relational resources.

263633 Errors occur when you simultaneously perform multiple activities on SAP R/3 resources using single or multiple user sessions.

259473 The impact summary of an IBM DB2 alias does not show the impacted objects of the base object.

259952 The lineage between a PowerCenter source and a Netezza table is missing when the connection used by the source is aNetezza bulk reader connection.

258486 On Windows 32-bit and 64-bit platforms, you cannot create SAP R/3 resources when you use SAP JCo 3.0.6 libraries.Workaround: Install SAP JCo 3.0.3 libraries before you create the SAP R/3 resources. Contact Informatica Global CustomerSupport.

257943 An error occurs when you profile Netezza resources.

257706 You cannot view lineage in a detached window when you use Mozilla Firefox.Workaround: View lineage in non-detached mode or view lineage in Microsoft Internet Explorer.

IN_RLN_95100_0001 33

Page 34: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

CR Description

256814 You cannot load a JDBC resource if you do not specify the correct path to the data direct JAR file.Workaround: Make sure that you specify the absolute path to the data driver file during JDBC resource configuration.

256672 Testing a connection to a JDBC resource on DB2/iSeries fails when you place the driver JAR file in a shared location.Workaround: Make sure that the JDBC driver JAR files are available on the same host as the Metadata Manager Agent.

255924 For a JDBC resource for DB2/iSeries, a view that is created on a table with a name longer than ten characters is not linked tothe table.

255780 When there are multiple instances of the same worklet in a single workflow, the workflow names are listed multiple times whenyou assign the parameter file during PowerCenter resource configuration.

255014 When you load a JDBC resource for DB2/iSeries, system-defined views are loaded along with user-defined views.

254260 When a single object is used in multiple locations, the Referring Struct Location value in the link report appears incorrect.

247629 The Custom Metadata Configurator displays errors for a workflow import if you generate the custom workflow again for a customresource.Workaround: Remove the generated mappings and workflows from the Designer and Workflow Manager and generate theworkflows from the Custom Metadata Configurator.

240743 Cannot restore the PowerCenter repository when the Metadata Manager Service runs on a worker node.Workaround: Verify that the PowerCenter repository has no content and enable the Metadata Manager Service.

237928 If you upgrade from version 8.6.1, data lineage displays links between source relational tables and PowerCenter sourcedefinitions and Source Qualifier transformations. Data lineage should display links between source relational tables andPowerCenter Source Qualifier transformations only.Workaround: Purge and then reload all PowerCenter resources. Recreate relationships from custom objects and business termsto PowerCenter metadata objects.

236963 You delete a user in the Informatica domain who is a data steward or owner for a category or a business term. However,Metadata Manager does not remove the deleted user from the data steward or owner assignment.Workaround: After deleting a user who is a data steward or owner for a category or business term, reassign another user as thedata steward or owner.

233569 A PowerCenter resource can contain multiple instances of a mapplet where each mapplet instance is linked to a different sourcerelational table. When you launch data lineage or view the impact summary for one of the source relational tables, lineage andthe impact summary display all instances of the mapplet. Data lineage and the impact summary should display only the mappletinstance linked to the source table.

232802 When the Metadata Manager repository is on a database that contains multibyte data, Metadata Manager cannot send an emailnotification when you propose a business term for review.

Informatica Global Customer SupportYou can contact a Customer Support Center by telephone or through the Online Support. Online Supportrequires a user name and password. You can request a user name and password at http://mysupport.informatica.com.

34 IN_RLN_95100_0001

Page 35: Release Notes December 2012 Version 9.5.1 Contents ... · 326101 After you run the Informatica Pre-Installation (i9Pi) System Check, when you run the Informatica installer and you

Use the following telephone numbers to contact Informatica Global Customer Support:

North America / South America Europe / Middle East / Africa Asia / Australia

Toll FreeBrazil: 0800 891 0202Mexico: 001 888 209 8853North America: +1 877 463 2435

Toll FreeFrance: 0805 804632Germany: 0800 5891281Italy: 800 915 985Netherlands: 0800 2300001Portugal: 800 208 360Spain: 900 813 166Switzerland: 0800 463 200United Kingdom: 0800 023 4632

Standard RateBelgium: +31 30 6022 797France: +33 1 4138 9226Germany: +49 1805 702 702Netherlands: +31 306 022 797United Kingdom: +44 1628 511445

Toll FreeAustralia: 1 800 151 830New Zealand: 09 9 128 901

Standard RateIndia: +91 80 4112 5738

IN_RLN_95100_0001 35