Report of Laboratory Exercises

  • Upload
    kkbar

  • View
    222

  • Download
    0

Embed Size (px)

Citation preview

  • 8/14/2019 Report of Laboratory Exercises

    1/12

  • 8/14/2019 Report of Laboratory Exercises

    2/12

    Report of laboratory

    exercises

  • 8/14/2019 Report of Laboratory Exercises

    3/12

    Application of flame atomic absorption

    spectrometric techniques to pharmaceuticals

    and waters

    Atomic absorption specroscopy is analytical method characterized with high

    selectivity,sensitivity and fast speed.

  • 8/14/2019 Report of Laboratory Exercises

    4/12

    Three different brands of multivitamins (effervescent tablets) were taken from the market

    and the levels of some elements (total amount) were determined (Ca, Mg, Zn, Cr, Mn)

    One tablet from each of the three pharmaceutical products was dissolved in 100ml (mother

    solution) water and one milliliter of each solution was diluted 25 times. So were prepared the

    working sample solutions and were marked as follows:

    Sample 1 (samp1) - ABO Pharma A-Z ;

    Sample 2 (samp2) - Supradyn ;

    Sample 3 (samp3) - Supravit Active ;

    A brand of mineral water - Gorna Banja was tested for any Mg and the concentration of

    the metal was under the detection limit of the instrument

    For each different element was made a standard calibration curve, using freshly prepared

    standard solutions from 0,5; 1; 3; 5; 10; 20ppm containing all the mentioned elements in water

    (deionized)

    For the last sample results were obtained both after automated calibration and a manually

    made calibration curve.

    Differences in the absorption using reducing and oxidizing flames were observed

  • 8/14/2019 Report of Laboratory Exercises

    5/12

  • 8/14/2019 Report of Laboratory Exercises

    6/12

    2.110%3

    2.410%2

    1.910%1

    Measuredvalues

    [ug/tablet]

    # Sample

    Pb calibration curve (ET AAS)

    y = 3,775x + 8,3333

    R2

    = 0,9909

    0

    50

    100

    150

    200

    250

    300

    350

    0 20 40 60 80 100

    concentration [ppb]

    absorption

    =283.3 nm

    1.910%3

    1.610%2

    8.910%1

    Measured

    values

    [ug/tablet]

    # Sample

    Cd calibration curve (ETAAS)

    y = 144,38x + 8,8333

    R2

    = 0,9828

    0

    50

    100

    150200

    250

    300

    0 0,5 1 1,5 2

    concentration [ppb]

    absoptio

    n

    =228.8 nm

    E t AA S

  • 8/14/2019 Report of Laboratory Exercises

    7/12

    Sample 1 (samp1) - ABO Pharma A-Z ;

    Manufacturer: ABO Pharma AG

    Sample 2 (samp2) - Supradyn ;

    Manufacturer: Bayer AG

    Sample 3 (samp3) - Supravit Active ;

    Manufacturer: Kendy Ltd Bulgaria

    Patented by Swisse AG

  • 8/14/2019 Report of Laboratory Exercises

    8/12

    IR spectra of benzocaine

  • 8/14/2019 Report of Laboratory Exercises

    9/12

    CH3, CH2

    def. vibr.

    CH3 (end)def. vibr.

    C-H str. vibr

  • 8/14/2019 Report of Laboratory Exercises

    10/12

  • 8/14/2019 Report of Laboratory Exercises

    11/12

    KBr Spectra benzocaine

    -NH2

    -CH2

    -C=O-NH2

    -Ar

    C-C

  • 8/14/2019 Report of Laboratory Exercises

    12/12

    Thank You for Your

    attentionLora Georgieva

    Denitsa AtanasovaKrum Bardarov