27
REV #1 – 10/11/12, ADD #3 – 11/05/12 00007-1 Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12 UniSpec II 123010 DOCUMENT 00007 - SEALS PAGE PROJECT: Name: Wal-Mart Location: Milwaukie, OR Project Number: 1122210 Store Number: 3144 ARCHITECT OF RECORD Daryl L. Bray SGA Architecture, P.C. 1437 South Boulder Suite 550 Tulsa, OK 74119 Division 1, Sections 02023, 02223, 02224, 02251, 02821, 02845, 02870, 03362, 03363, 03930, 04200, 05400, 05500, 06065, 06100, 06200, 06400, 06424, 06615, 06616, Divisions 7, 8, 9, 10, 11 Architect of Record Date CIVIL ENGINEERING CONSULTANT OF RECORD Refer to Civil Engineering Consultant Sections (Printed on Yellow Paper) Table of Contents for seal and signature of Civil Engineering Consultant of Record. 3 1

REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

Embed Size (px)

Citation preview

Page 1: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

REV #1 – 10/11/12, ADD #3 – 11/05/12

00007-1

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

UniSpec II 123010

DOCUMENT 00007 - SEALS PAGE

PROJECT: Name: Wal-Mart Location: Milwaukie, OR Project Number: 1122210 Store Number: 3144 ARCHITECT OF RECORD

Daryl L. Bray SGA Architecture, P.C. 1437 South Boulder

Suite 550 Tulsa, OK 74119 Division 1, Sections 02023, 02223, 02224, 02251, 02821, 02845, 02870, 03362, 03363, 03930, 04200, 05400, 05500, 06065, 06100, 06200, 06400, 06424, 06615, 06616, Divisions 7, 8, 9, 10, 11

Architect of Record Date CIVIL ENGINEERING CONSULTANT OF RECORD Refer to Civil Engineering Consultant Sections (Printed on Yellow Paper) Table of Contents for seal and signature of Civil Engineering Consultant of Record.

3 1

Page 2: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

00010-1

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

UniSpec II 062411

SECTION 00010 - TABLE OF CONTENTS Division Section Title INTRODUCTORY INFORMATION 00001 Project Title Page 00007 Seals Page 00010 Table of Contents BIDDING REQUIREMENTS Bidding Requirements (including Invitation to Bids, Instructions to Bidders, and Bid Forms) are issued by the Owner under separate cover and are not included in the Project Manual. CONTRACTING REQUIREMENTS Contracting Requirements (including Agreement, General Conditions, Bond, and Certificate Forms) are issued by the Owner under separate cover and are not included in the Project Manual. DIVISION 1 - GENERAL REQUIREMENTS 01100 Summary 01255 Request For Information 01310 Project Management and Coordination 01320 Construction Progress Documentation 01330 Submittal Procedures 01432 Electrical Installer Qualifications 01452 Contractor's Quality Control 01454 Architect-Engineer Quality Assurance 01455 Mechanical Equipment Testing, Adjusting, and Balancing 01456 Civil Engineering Consultant Quality Assurance Inspection 01458 Laboratory Testing Services 01459 Neutralization Enclosure Quality Control 01500 Temporary Facilities and Controls 01600 Product Requirements 01640 Owner Furnished Products 01645 Owner Furnished Products Sources 01700 Execution Requirements 01731 Cutting and Patching 01740 Cleaning 01742 Construction/Demolition Waste Management and Disposal 01743 Hazardous/Universal Waste Management and Disposal 01770 Contract Closeout DIVISION 2 - SITE CONSTRUCTION 02023 Selective Site Demolition 02223 Removal and Recycling of Vinyl Composition Tile (VCT) 02224 Removal and Recycling of Acoustical Ceiling Tile (ACT) 02251 Shoring 02260 Excavation Support and Protection ADD NEW SECTION 02821 Chain Link Fences And Gates (Building Related)

3

Page 3: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

00010-2

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

02845 Cart Corral 02870 Site Furnishings

DIVISION 2.1 - SITE CONSTRUCTION (CIVIL ENGINEERING CONSULTANT DESIGN) The Sections within this Division and other Divisions listed within the Wal-Mart Sitework Specifications Table of Contents page are the responsibility of the Civil Engineering Consultant, and not the responsibility of the Architect of Record. The Civil Engineering Consultant, the seal and license number of the Professional Engineer registered in the State where the project is located, are also shown on the Wal-Mart Sitework Specifications Table of Contents page. DIVISION 3 - CONCRETE 03310 Structural Concrete and Exterior Concrete Slabs 03312 Cast-in-place Concrete Slabs (Interior) 03362 Burnished Concrete Floor Finishes 03363 Burnished Concrete Floor Finishes (Existing Floors) 03930 Concrete Rehabilitation DIVISION 4 - MASONRY 04012 Unit Masonry Maintenance – Efflorescence Removal ADD NEW SECTION 04200 Unit Masonry Assemblies DIVISION 5 - METALS 05090 Post-installed Concrete and Masonry Anchors 05120 Structural Steel 05400 Cold Formed Metal Framing 05500 Metal Fabrications DIVISION 6 - WOOD AND PLASTICS 06065 Plastic Materials 06100 Rough Carpentry 06108 Pressure Treated Exterior Solid Sawn Lumber 06180 Glued-Laminated Timbers 06200 Finish Carpentry 06400 Architectural Woodwork 06424 Protective Surfacing 06615 Non-fiberglass Reinforced Plastic Panels 06616 Simulated Stone Fabrications DIVISION 7 - THERMAL AND MOISTURE PROTECTION 07210 Building Insulation 07243 Water-drainage Exterior Insulation And Finish System (EIFS) 07500 Membrane Roofing 07620 Sheet Metal Flashing and Trim 07721 Manufactured Curbs 07722 Roof Hatches 07900 Joint Sealers DIVISION 8 - DOORS AND WINDOWS 08110 Steel Doors and Frames 08311 Access Doors and Frames 08332 Overhead Rolling Closure 08360 Sectional Overhead Doors

3

Page 4: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

00010-3

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

08381 Flexible Strip Doors 08383 Traffic Doors 08710 Door Hardware 08800 Glazing DIVISION 9 - FINISHES 09250 Gypsum Board 09310 Ceramic Tile 09511 Acoustical Panel Ceilings 09650 Resilient Flooring 09655 Resilient Base and Accessories 09680 Carpet 09900 Paints and Coatings DIVISION 10 - SPECIALTIES 10160 Metal Toilet Compartments 10240 Rooftop Equipment Screens 10260 Wall and Corner Guards 10810 Toilet Accessories DIVISION 11 - EQUIPMENT 11025 Lock Boxes 11160 Loading Dock Equipment 11400 Food Service Equipment DIVISION 12 - FURNISHINGS NOT APPLICABLE DIVISION 13 - SPECIAL CONSTRUCTION 13080 Seismic Protection for Mechanical, Electrical and Refrigeration Equipment. 13425 Sub-metering Instrumentation 13810 Energy Management System (EMS) 13900 Fire Suppression DIVISION 14 - CONVEYING SYSTEMS NOT APPLICABLE DIVISION 15 - MECHANICAL 15050 Basic Mechanical Materials and Methods 15100 Building Services Piping and Equipment 15190 Fuel Gas Piping 15410 Plumbing Fixtures 15480 Domestic Water Heaters 15600 Refrigeration Systems 15700 Heating, Ventilating, and Air Conditioning Equipment 15800 Air Distribution DIVISION 16 - ELECTRICAL 16050 Basic Electrical Materials and Methods 16100 Wiring Methods 16265 Static Uninterrupted Power Supply 16402 Low Voltage Service and Distribution 16410 Enclosed Switches and Circuit Breakers 16442 Branch Circuit Panelboard

Page 5: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

00010-4

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

16452 Track Busway Systems 16500 Lighting 16700 Communications END OF TABLE OF CONTENTS

Page 6: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

02260 - 1

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

SECTION 02260 - EXCAVATION SUPPORT AND PROTECTION ADD NEW SECTION

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section includes requirements for permanent solder pile retaining wall.

B. Related Requirements: 1. Section 03310 "Structural Concrete and Exterior Concrete Slabs" for soldier pile shaft

concrete and reinforcing.

1.3 PREINSTALLATION REQUIREMENTS

A. Preinstallation Review 1. Review geotechnical report. 2. Review existing utilities and subsurface conditions. 3. Review coordination for interruption, shutoff, capping, and continuation of utility

services. 4. Review proposed excavations. 5. Review proposed equipment. 6. Review monitoring of excavation support and protection system. 7. Review coordination with waterproofing. 8. Review abandonment or removal of excavation support and protection system. 9. Review construction documents pertaining to soldier pile wall.

1.4 FIELD CONDITIONS

A. Interruption of Existing Utilities: Do not interrupt any utility serving facilities occupied by Owner or others unless permitted under the following conditions and then only after arranging to provide temporary utility according to requirements indicated: 1. Notify Owner’s Construction Manager no fewer than 5 days in advance of proposed

interruption of utility. 2. Do not proceed with interruption of utility without written permission from the Owner’s

Construction Manager.

3

Page 7: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

02260 - 2

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

B. Project-Site Information: A geotechnical report has been prepared for this Project and is available for information only. The opinions expressed in this report are those of a geotechnical engineer and represent interpretations of subsoil conditions, tests, and results of analyses conducted by a geotechnical engineer. Owner is not responsible for interpretations or conclusions drawn from the data. 1. The geotechnical report is included elsewhere in Project Manual.

PART 2 - PRODUCTS

2.1 PERFORMANCE REQUIREMENTS

A. Provide, monitor, and maintain excavation support and protection system capable of supporting excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and construction loads as indicated on the construction documents 1. Contractor Design: Design temporary wood lagging between soldier piles, including

comprehensive engineering analysis by a qualified professional engineer licensed in the state of this project.

2. Prevent surface water from entering excavations by grading, dikes, or other means. 3. Install excavation support and protection systems without damaging existing buildings,

structures, and site improvements adjacent to excavation. 4. Continuously monitor vibrations, settlements, and movements to ensure stability of

excavations and constructed slopes and to ensure that damage to permanent structures is prevented.

2.2 MATERIALS

A. General: Provide materials that are either new or in serviceable condition.

B. Structural Steel: Galvanized ASTM A 992/A 992M.

C. Wood Lagging: Lumber, nominal rough thickness and species as specified by temporary shoring engineer licensed in the state of the project.

D. Cast-in-Place Concrete: Comply with Section 03310, of compressive strength indicated on construction documents.

E. Reinforcing Bars: ASTM A 615/A 615M, Grade 60, deformed.

Page 8: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

02260 - 3

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

PART 3 - EXECUTION

3.1 PREPARATION

A. Protect structures, utilities, sidewalks, pavements, and other facilities from damage caused by settlement, lateral movement, undermining, washout, and other hazards that could develop during excavation support and protection system operations. 1. Shore, support, and protect utilities encountered.

B. Install excavation support and protection systems to ensure minimum interference with roads, streets, walks, and other adjacent occupied and used facilities. 1. Do not close or obstruct streets, walks, or other adjacent occupied or used facilities

without permission from Owner and authorities having jurisdiction. Provide alternate routes around closed or obstructed traffic ways if required by authorities having jurisdiction.

C. Locate excavation support and protection systems clear of permanent construction so that construction and finishing of other work is not impeded.

3.2 SOLDIER PILES AND LAGGING

A. Drill soldier pile shaft and install reinforcing cage as indicated on the construction documents.

B. Install steel soldier piles before starting excavation. Extend soldier piles below excavation grade level to depths indicated on the construction documents. Space soldier piles as indicated on construction documents. Accurately align exposed faces of flanges to vary not more than 2 inches from a horizontal line and not more than 1:120 out of vertical alignment.

C. Fill soldier pile shaft with concrete as indicated on the construction documents.

D. Wood lagging shall be designed by temporary shoring engineer licensed in the state of this project.

E. Install wood lagging within flanges of soldier piles as excavation proceeds. Trim excavation as required to install lagging. Fill voids behind lagging with soil, and compact.

3.3 FIELD QUALITY CONTROL

A. Survey-Work Benchmarks: Resurvey benchmarks regularly during installation of excavation support and protection systems, excavation progress, and for as long as excavation remains open. Maintain an accurate log of surveyed elevations and positions for comparison with original elevations and positions. Promptly notify Architect if changes in elevations or positions occur or if cracks, sags, or other damage is evident in adjacent construction.

Page 9: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

02260 - 4

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

B. Promptly correct detected bulges, breakage, or other evidence of movement to ensure that excavation support and protection system remains stable.

C. Promptly repair damages to adjacent facilities caused by installation or faulty performance of excavation support and protection systems.

3.4 PERMANENT RETENTION REQUIREMENTS

A. Leave excavation support and protection systems permanently in place.

B. Contractor is to remove as much wood lagging as possible, a minimum of 2 feet, and fill void space with compacted backfill.

END OF SECTION

Page 10: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

04012-1

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

SGA/pch 040112

SECTION 04012 – UNIT MASONRY MAINTENANCE – EFFLORESCENCE REMOVAL ADD NEW SECTION

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes: Removal of efflorescence from CMU block wall.

B. Related Requirements: 1. Section 04200 - Unit Masonry Assemblies: Masonry wall.

1.2 DELIVERY, STORAGE, AND HANDLING

A. Store in a cool, dry place with adequate ventilation. Always seal container after dispensing. Do not alter or mix with other chemicals.

B. Maintain temperatures of 45⁰ to 100⁰ F. Do not apply when temperature is below freezing or will be overnight. If freezing conditions exist before application, let the surface thaw.

C. Do not double stack pallets. Dispose of unused product and container in accordance with local, state and federal regulations.

1.3 PROJECT CONDITIONS

A. Perform repairs to CMU wall, parapet cap or other areas determined to be source of water infiltration prior to ef-florescence removal.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Provide cleaning products by the following acceptable manufacturer: 1. Prosoco, Lawrence, KS (800) 255-4255. 2. Substitutions not allowed.

2.2 PRODUCTS

A. Acceptable Products: Remove efflorescence from CMU block wall using one of the following products: 1. Interior Block Surface:

a. Safety Klean, by Prosoco. 2. Exterior Gray Block Surface:

a. Light Efflorescence: Sure Klean Light Duty Cleaner, by Prosoco. b. Heavy Efflorescence: Sure Klean Heavy Duty Concrete Cleaner, by Prosoco.

3. Exterior Integrally Colored Block Surface: a. Sure Klean Custom Masonry Cleaner, by Prosoco.

4. Substitutions not allowed.

3

Page 11: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

04012-2

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

PART 3 - EXECUTION

3.1 PROTECTION

A. Protect people, vehicles, property, metal, painted surfaces, plants and other non-masonry materials from product, rinse, splash, residue, wind drift and fumes. When working near vehicular traffic, clean when traffic is at a mini-mum. Protect or divert traffic as needed.

3.2 FIELD QUALITY CONTROL

A. Site Test: Test a minimum 4 ft. by 4 ft. area on each type of masonry. Use manufacturer’s application instruc-tions. Let the test panel dry 3 to 7 days before inspection.

B. Test with the same equipment, recommended surface preparation and application procedures planned for general application.

3.3 APPLICATION

A. Apply concrete cleaner in accordance with manufacturer’s written instructions. Dilute per manufacturer’s recom-mendations.

B. When cleaning vertical surfaces, keep lower areas wet to avoid streaks.

END OF SECTION

Page 12: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-1

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

UniSpec II - Base 042712a

SECTION 08710 (08 7100) - DOOR HARDWARE

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes: 1. Hardware for doors. 2. Thresholds. 3. Weatherstripping, seals and door gaskets.

B. Related Requrements: 1. Section 01640 - Owner Furnished Products: Provisions for Owner Furnished Items. 2. Section 01645 – Owner Furnished Products Sources: Manufacturers, suppliers, and vendor

contacts and product names and numbers related to Owner furnished products. 3. Section 06100 - Rough Carpentry: Blocking for miscellaneous hardware mounting. 4. Section 06200 - Finish Carpentry: Hardware for cabinetry and other finish carpentry. 5. Section 08110 - Steel Doors and Frames: Hardware coordination. 6. Section 08331 - Coiling Counter Doors: Hardware coordination. 7. Section 08411 - Aluminum Framed Storefronts: Hardware coordination. 8. Section 08461 - Automatic Swing Entrance Doors: Hardware coordination. 9. Section 08462 - Automatic Sliding Entrance Doors: Hardware coordination. 10. Section 16100 - Wiring Methods: Electrified hardware coordination.

1.2 REFERENCES

A. The publications listed below form a part of this specification to the extent referenced. Publications are referenced within the text by the basic designation only.

B. Americans with Disabilities Act (ADA): 1. 28 CFR Part 36 - ADA Standards for Accessible Design.

C. American National Standards Institute (ANSI): 1. ANSI A 117.1 - Accessible and Useable Building and Facilities. 2. ANSI A 156.2 - Bored and Preassembled Locks and Latches. 3. ANSI A 156.6 - Architectural Door Trim. 4. ANSI A 156.13 - Mortise Locks and Latches. 5. ANSI A 156.15 - Release Devices – Closer Holder, Electromagnetic and Electromechanical.

D. National Fire Protection Association (NFPA): 1. NFPA 80 - Fire Doors and Windows. 2. NFPA 101 - Code for Safety to Life from Fire in Buildings and Structures. 3. NFPA 252 - Fire Tests of Door Assemblies.

E. Underwriters Laboratories (UL): 1. UL 10B - Fire Tests of Door Assemblies. 2. UL 305 - Panic Hardware.

1.3 SUBMITTALS

A. Comply with the requirements of Section 01330.

Page 13: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-2

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

1.4 DELIVERY, STORAGE AND HANDLING

A. Transport, handle, store, and protect door hardware products in compliance with the requirements of Section 01600 and manufacturer's recommendations.

B. Product Delivery: Owner’s Supplier will deliver products to Site ready for installation. Contact Owner’s Supplier to establish product delivery and installation date and coordination procedure.

C. Product Packaging: Products will be shipped in manufacturer's standard packaging with identification markings on each component or package.

D. Acceptance at Site: Receive products as specified in Section 01640. 1. Verify quantity of products furnished with Bills of Lading provided with products. 2. Report discrepancies in product quantity or quality, or damage or damage to products to Owner’s

Construction Manager immediately. Note description of product quality discrepancies and/or product damage on Bill of Lading.

3. Upon notification, Owner will arrange for delivery of replacement products.

E. Store products in unopened packages in protected dry area to prevent damage from environmental and construction operations.

PART 2 - PRODUCTS

2.1 OWNER FURNISHED PRODUCTS

A. Owner's or Owner’s Supplier will furnish hardware specified herein under provisions of Section 01640 for installation by Contractor.

B. Descriptions and related provisions of products by Supplier as specified herein are included as requirements by the supplier of equipment to be furnished by the Owner and are included as information only to Contractor.

2.2 MANUFACTURERS

A. Provide hardware as scheduled in Hardware Schedule in Part 3 of this Section.

B. Owner’s Supplier: 1. Reference corresponding paragraph in Section 01645.

C. Product Designations: Hardware may be any of the products listed within the tables below for each specific type. Substitutions will not be permitted.

D. Hardware Manufacturer Designations: ID Manufacturer Telephone ID Manufacturer Telephone Ar Arrow (ASSA ABLOY) (800) 233-0478 Re Reese Enterprises, Inc. (800) 328-0953 De Detex Corporation (800) 729-3839 Ri Rixson (ASSA ABLOY) (800) 457-5670 GJ Glynn-Johnson (Ingersoll Rand

Security Technologies (IR) (800) 525-0336 Ro Rockwood (ASSA ABLOY) (814) 926-2026

H Hager Companies (800) 325-9995 Sc Schlage (IR) (800) 847-1864 I H. B. Ives (IR) (877) 613-8766 Sec Securitron (ASSA ABLOY) LCN LCN Closers (IR) (800) 526-2400 Sel Select Hinges (800) 423-1174 Mc McKinney (ASSA ABLOY) (717) 346-7551 S Stanley Hardware (800) 622-4393 NG National Guard Products, Inc. (800) 647-7874 T Trimco (Triangle Brass Mfg) (800) 637-8746 P Pemko Mfg. Co. (805) 642-2600 VD Von Duprin (IR) (800) 999-0408

Page 14: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-3

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

ID Manufacturer Telephone ID Manufacturer Telephone Po Positive Lock (800) 342-7670

2.3 REGULATORY REQUIREMENTS

A. Perform work in accordance with the following standards: 1. ANSI A117.1 2. NFPA 101. 3. NFPA 80. 4. NFPA 252. 5. UL 10B. 6. UL 305.

B. Conform to applicable code for requirements applicable to fire rated doors and frames.

C. Products Requiring Electrical Connection: Listed and classified by Underwriters Laboratories, Inc. (UL), and acceptable to Authority Having Jurisdiction as suitable for the purpose specified and indicated.

D. Conform to applicable local, State or Federal disabled access requirements for the installation and operation of door hardware.

2.4 FINISHES

A. Provide finishes as specified in Part 2 of this Section unless otherwise indicated in the Hardware Schedule for the specific hardware item.

2.5 HINGES

A. Material: 1. Mortise Butts: Provide full mortise-type hinges with stainless steel pins, except steel pins with steel hinges;

non-removable pin (NRP) for exterior and public interior exposure, non-rising pin, flat button with matching plugs, 4-1/2 inches x 4-1/2 inches unless otherwise shown.

2. Ball-bearing Type Hinges: Swaged, inner leaf beveled, square corners. 3. Continuous Geared Hinge: Full surface type hinge of 6063 T6 Aluminum with thermoplastic polyester

bearings, 90 min. fire rated, clear finish. Provide self drilling threaded fasteners for frame and thru bolts for door.

B. Hinges by types: Type Description Finish MANUFACTURER/MODEL Stanley Hager McKinney H-2 Butts: Medium weight door, low frequency,

steel 652 F179 1279 T2714

H-4 Butts: Medium weight door, average frequency, steel

652 FBB179 BB1279 TB2714

Select Hinge Hager H-7 Hinge: Continuous geared hinge CL SL21 SD x

SDTF x FDH

Roton 780-210

Stanley Hager McKinney H-8 Hinge: Surface mounted 3 inches x 3 inches US2H 808BP 1808 705 H-9 Butts: Heavy weight, stainless steel 630 FBB199 BB1199 T4B3386 H-11 Butts: Medium weight, stainless steel 630 FBB191 BB1191 TB3386

Page 15: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-4

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

2.6 LOCKS, LATCHES, AND BOLTS

A. Materials: 1. Cylindrical Locks: ANSI A 156.2, Series 4000 Grade 1, equipped with 6-pin tumbler; "keyed alike.

Provide 2-3/4 inch backset. Provide two keys for each lock. 2. Mortise Locks: ANSI A 156.13, Grade 1, equipped with 6-pin tumbler; "keyed alike. Provide 2-3/4 inch

backset. Provide two keys for each lock.. 3. Provide Schlage standard C123 keyway (except Pharmacy) 4. Provide Schlage Primus XP cylinders for Pharmacy 300 series locks. 5. Master key, key alike or different as directed. 6. Quantity: In addition to two keys for each lock, provide the following:

a. Cylinder Change Keys: 6 change keys per change b. Master Keys: 10.

7. Latch Sets: Provide push-button releases by turning lever, closing door, or turning emergency release key through hole in outside knob.

8. Strikes: ANSI Strikes, 1-1/4 x 4-7/8 inches, with curved lip. Wrought box strikes, with extended lip for latch bolts, except open strike plates may be used in wood frames. Provide dustproof strikes for foot bolts.

9. Tactile Warning: Provide locks with tactile warning for handicapped codes when required by Authority Having Jurisdiction.

B. Locks by types: Type Description Finish MANUFACTURER/MODEL Schlage L-1 Mortise Cylinder 626 20-001 L-2 Mortise Cylinder 626 20-001-1-1/4 inches L-3 Rim Cylinder 626 20-022 L-4 Classroom Lock 626 ND70PD-Rhodes L-5 Storeroom Lock (F86) 626 ND80PD-Rhodes-25 L-6 Office Lock (F82) 626 ND50PD-Rhodes-10-025 L-7 Passage Latch (F75) 626 ND10S-Rhodes-10-025 L-8 Privacy Lock (F76) 626 ND40S-Rhodes-10-025 L-9 Dead Bolt Lock 626 B661P L-10 Access Control Lock 626 CO-100-CY-70-KP-RHO-626PD L-11 Entrance Lock (F81/82) 626 ND53PD-Rhodes-10-025 L-12 Storeroom Lock with

deadbolt 626 L9480-06L

L-13 Institutional Lock (F87) 626 ND82PD-Rhodes-10-025 L-15 Entrance Lock with deadbolt 626 L9453-06L L-16 Dead Bolt Lock with

Thumbturn (Classroom Function)

626 B663P

L-17 Storeroom Lock (Grade 2) 626 AL80PD-Saturn L-18 Privacy Lock (Grade 2) 626 AL40S-Saturn L-20 Office Lock

(Grade 2) 626 AL50PD-Saturn

L-21 Passage Latch (Grade 2) 626 AL10S-Saturn L-22 Thumbturn 626 09-905NHxB502-292

2.7 EXIT DEVICES

A. Materials: 1. Provide exposed metal to match hardware.

Page 16: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-5

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

2. Size and mount units indicated or, if not indicated, to comply with manufacturer's recommendations for exposure condition. Reinforce substrate as recommended.

B. Exit Devices by types: Type Description Finish MANUFACTURER/MODEL Von Duprin unless otherwise noted. E-1 Exit Device: Rim, exit only, UL listed. 626 99EO-F E-2 Exit Device: Rim, exit only, with alarm. Provide exterior

access model, time delay, or weatherproof when scheduled. 600 Positive Lock:

THPA Series (Size as required for door scheduled) O/A - Outside Access TDL -Time Delay WE - Weatherproof

E-3 Exit Device: Surface vertical rod (top rod only), lever trim, blank escutcheon, UL listed.

626 9927L-F-BE-LBR

E-4 Exit Device: Concealed vertical rod, lever trim, blank escutcheon, UL listed

626 9948L-F-BE

E-5 Exit Device: Rim, lever trim, blank escutcheon, UL listed. 626 99L-F-BE E-7 Exit Device: Rim, pull trim. 626 99NL x 697NL E-8 Exit Device: Rim delay exit device, pull trim, with alarm.

Power Transfer #EPT-10 Power Supply #PS 914

626 SP28

CX9975L x 992L (06 Lever)

E-10 Exit Device: Rim, exit only 626 99EO E-11 Exit Device: Rim, weatherproof, exit only, with alarm. 626 Detex:

V40 EB W AL RWE E-14 Exit Device: Vertical Rod, exit only, with alarm. Provide

outsite access model or time delay when scheduled. 600 Positive Lock:

THPA Series (O/A) - Outside Access (TDL) -Time Delay

E-16 Exit Device: Rim, lever trim 626 99L-992L-NL E-18 Exit Device: Rim, lever trim, UL Listed 626 99L-F-992L-NL E-19

Exit Device: Surface vertical rod, no outside trim, exit only, UL listed.

626 9927EO-F

E-20 Exit Device: Rim, lever trim, blank escutcheon 626 99L-BE E-21 Exit Device 626 99EO E-23 Exit Device: Rim, lever trim, with alarm

Power Transfer #EPT-10 Power Supply #PS-914

626 SP28

CX99NL-F x 696-NL

E-24 Exit Device: Rim, lever trim, with alarm Power Transfer #EPT-10 Power Supply #PS-914

626 SP28

CX99EO-F

2.8 PULLS AND PUSHES

A. Materials: ANSI A 156.6 for 0.050 inch thickness.

B. Push and Pulls by types: Type Description Finish MANUFACTURER/MODEL Ives Trimco Rockwood P-1 Push 3-1/2 x 15 630 8200 1001-2 70B P-2 Pull 3-1/2 x 15 630 8311-5 1012-2 137x70B P-3 Pull 8 inches CTC x 3/4 inch 630 8103-8 1194-2 107

Page 17: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-6

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

Type Description Finish MANUFACTURER/MODEL Ives Trimco Rockwood

dia P-4 Pull 5-1/4 cc 630 8111-5 1102T 132 P-5 Pocket Door Pull Latching black 1069L

2.9 CLOSERS

A. Materials & Features: 1. ANSI A 156.4, grade 1. 2. ADA/ANSI A117.1 3. UL listed. 4. Non-handed, non-sized; adjustable 1-6. 5. 180 degree door opening. 6. Standard cover. 7. Multiple backcheck location valve. 8. Extreme temperature fluid. 9. Sex nuts and bolts (SNBs). 10. Provide exposed metal to match hardware. 11. Size and mount units indicated or, if not indicated, to comply with manufacturer's recommendations for

exposure condition. Reinforce substrate as recommended.

B. Closers by types: Type Description Finish MANUFACTURER/MODEL LCN C-4 Closer: Regular Arm 689 4011-REG C-5 Closer: Parallel Arm 689 4111-EDA C-6 Closer: Regular Arm 689 4031-REG C-7 Closer: Parallel Arm 689 4031-EDA C-8 Closer: Parallel Arm, HO 689 4111-HEDA C-9 Closer: Parallel Arm, HO, positive

stop 689 4111-H-CUSH

C-10 Closer: Regular Arm, HO 689 4031-H C-11 Closer: Parallel Arm, positive stop 689 4031-CUSH C-12

Closer: Parallel Arm, positive stop 689 4111-CUSH

2.10 DOOR PROTECTION PLATES

A. Materials: J100 Protection Plates conforming to ANSI A 156.6, stainless steel, 0.050" (1.2 mm) minimum thickness. Mount centered, flush with bottom of door. Screws: Phillips head sheet metal screws plated to match plate.

B. Protection Plates by types: Type Description Size Finish MANUFACTURER/MODEL Ives Trimco Rockwood K-2 Kick Plate 10" x (DW-2") 630 8400 K1050 J102 K-3 Armor Plate 34" x (DW-2") 630 8400 K1050 J101 K-4 Armor Plate 41” x (DW-2”)

Notch for lockset 630 8400 K1050 J101

K-5 Kick Plate 18" x (DW-2") 630 8400 K1050 J102

Page 18: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-7

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

Type Description Size Finish MANUFACTURER/MODEL Ives Trimco Rockwood K-6 Armor Plate (UL Rated) 34" x (DW-2") 630 8402 UL KA050-2 Fire Rated K1050F K-7 Armor Plate (UL Rated) 36" x (DW-2") 630 8402 UL KA050-2

Fire Rated K1050F

2.11 STOPS, HOLDERS AND BUMPERS

A. Materials: 1. Door stop mounting: Methods to suit substrates encountered (plastic anchor, drywall anchor, expansion

shield). 2. Provide gray rubber exposed resilient parts. 3. Do not furnish aluminum floor stops. 4. For most doors, the preferred door stop is Wall Stop type S-1 and is specified as such in the hardware

schedule. However, if circumstances prevent a wall stop installation (door too far from perpendicular wall, door swing into adjacent glass, etc.) then substitute a type S-3 or S-4 floor stop as indicated for use intended.

5. Adjust height of floor stops to suit undercut of adjacent door.

B. Stops, Holders and Bumpers by types: Type Description Finish MANUFACTURER/MODEL Ives Trimco Rockwood S-1 Wall Stop 630 WS407CVX W1276CS 409 S-2 Stop & Holder 626 FS445 1207 477 S-4 Floor Stop 626 FS438 1212 3/4ES 442 Rixson Glynn-Johnson S-5 Overhead Stop - 3-0 doors 626 9-336 904S S-6 Overhead Stop - 2-6 doors 626 9-236 902S Ives Trimco Rockwood S-7 Stop & Holder. Kick down

type satin chrome FS452-4 1220-4FF 458

Rixson Glynn-Johnson S-8 Overhead Stop. Medium duty 630 10-336 454S

2.12 ELECTROMAGNETIC DOOR HOLDERS

A. Materials & Features: 1. ANSI A 156.15, Grade 1. 2. UL listed. 3. Magnet protected against transients and surges up to 600 volts. 4. 24V DC 5. Holding force 35 lbs., nominal. 6. Low residual magnetism for easy release of door. 7. Electrical values +10% -15%. 8. Provide exposed metal to match hardware.

B. Electromagnetic Door Holders by types:

Type Description Finish MANUFACTURER/MODEL

LCN Rixson DH-1 Door Holder 689 SEM 7850 689 FM-998 SA

Page 19: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-8

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

2.13 THRESHOLDS

A. Thresholds by types: Type Description MANUFACTURER/MODEL National

Guard Pemko Reese

T-1 Threshold: 5 inches x 1/2 inch, abrasive. 425HD-SIA 5”

1715AK 5”

T-4 Threshold: 2 inches x 1/8 inch, stainless steel plate, smooth surface, beveled 1 side only. Transition threshold between concrete slab and vinyl tile. Set threshold in full bed of silicone sealant, butted to adjacent vinyl tile. Anchor into concrete slab with Hilti Kwik-Con II, #14-134 TFH fasteners spaced at 6-inch centers using Matched Tolerance drill bit for dense concrete.

BAR6SS-2-10bevel

T-9 Threshold: 5 inches, aluminum, stop seal 896S 2005AT S483AS T-10 Threshold: 5 inches, aluminum, stop seal 898V 2006AT

2.14 WEATHERSTRIPPING

A. Weatherstripping by types: Type Description MANUFACTURER/MODEL National Guard Pemko Reese W-3 Door Bottom Sweep, surface mounted sweep, anodized

aluminum, neoprene seal. 201NA 315CN 323A

W-4 Meeting Stile Gaskets, aluminum, silicone insert seal. 160S 303AS 807A W-5 Jamb Door Gaskets, adhesive application, silicone seal. 5050B S88D 797B W-9 Jamb and Head Weatherstripping: Self Adhesive Seal 5075B S773D

2.15 MISCELLANEOUS HARDWARE

A. Silencers: Provide in metal door frames, unless not permitted for fire rating, or unless bumper-type weatherstripping is provided; three for each single door frame, two for double-door frame.

B. Miscellaneous Hardware by types: Type Description Size Finish MANUFACTURER/MODEL Stanley Ives Rockwood M-1 Hasp &

Staple 3-1/2 inches

602 SP915 WS1920

M-3 Surface Bolt 4 inches 626 40 630 M-4 Viewer 626 700 620 Ives Trimco Rockwood M-5 Extension

Flush Bolts (UL)

12 inches

626 458 3917 555

M-6 Automatic Flush Bolt

626 FB42 1948

Ives Trimco Rockwood M-8 Silencers SR64 1229-A 608 National Guard Pemko Reese M-9 Drip Cap 16A 346CxFW R201A Ives Trimco

Page 20: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-9

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

Type Description Size Finish MANUFACTURER/MODEL Stanley Ives Rockwood M-10 Door Coordinator COR x MB x FL 3092 x MB x W Arrow Detex M-11 Door Alarm 626 130 Series AL EAX-500 M-12 Door Alarm gray Alarm: EAX-2500F

Transformer: PP5152-3 Rockwood M-14 Mail Slot 630 RS-2-1251-32D M-15 Latch Protector 630 321 Von Duprin Schlage Securitron M-16 Electric Strike, grade 1,

FSE (fail secure), 24VDC unless noted otherwise in schedule

630 6211

M-17 Power Supply PS902 M-18 Push Button 660PB M-19 Electric Strike 626 UNL-24 M-20 Power Supply BPS-24-1 M-21 Keypad & Controller DK-26SS M-21a Keypad DK-26PSS Von Duprin M-24 Mullion 626 9954 M-25 Strike 626 499F

2.16 FABRICATION

A. Finish and Base Material Designations: Number indicates Builders Hardware Manufacturer’s Association (BHMA) Code or nearest traditional U.S. commercial finish.

B. Where base material and quality of finish are not otherwise indicated, provide at least commercially recognized quality.

C. Fasteners: Provide door hardware manufactured to comply with published templates prepared for machine, wood, and sheet metal screws. Provide screws that comply with commercially recognized industry standards for application intended, except aluminum fasteners are not permitted. Provide Phillips flat-head screws with finished heads to match surface of door hardware, unless otherwise indicated. 1. Fire-Rated Applications:

a. Wood or Machine Screws: For the following: 1) Hinges mortised to doors or frames. 2) Strike plates to frames. 3) Closers to doors and frames.

b. Steel Through Bolts: For the following unless door blocking is provided: 1) Surface hinges to doors. 2) Closers to doors and frames. 3) Surface-mounted exit devices.

2. Spacers or Sex Bolts: For through bolting of hollow-metal doors. 3. Gasketing Fasteners: Provide noncorrosive fasteners for exterior applications and elsewhere

as indicated.

Page 21: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-10

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

PART 3 - EXECUTION

3.1 EXAMINATION

A. Verify that doors and frames are ready to receive Work and dimensions are as instructed by the manufacturer.

B. Verify that electric power is available to power operated devices and of the correct characteristics.

3.2 INSTALLATION

A. Hardware Mounting Heights: Door and Hardware Institute Recommended Locations for Builders Hardware for Standard Steel Doors and Frames, except as otherwise indicated. 1. Conform to requirements of applicable local, State or Federal disabled access requirements for the

installation and operation of door hardware. 2. Install electromagnetic door holder at 24 inches above finish floor elevation at manufacturer’s

recommended distance from the door’s leading edge.

B. Install each hardware item to comply with manufacturer's instructions and recommendations, unless otherwise specified.

C. Thru-bolt closers on doors.

D. Vestibule Thresholds: Install as shown on Drawings.

3.3 FIELD QUALITY CONTROL BY OWNER

A. Manufacturer's Technical Representative will provide site observation at completion of installation of doors and hardware including the following. 1. Inspect closers; exit devices (except Detex and Positive Lock); locks, latches, and bolts; and electric strikes. 2. Verify hardware installed is as specified. 3. Verify proper installation. 4. Verify proper operation.

B. Manufacturer’s Technical Representative shall be the manufacturer of the items to be inspected. Contractor shall notify the following manufacturer’s represententive completion of installation doors and hardware: 1. Jerry Davis, IR Security & Safety National Accounts Manager (678) 906-2106,

[email protected].

C. Manufacturer’s Technical Representative will prepare Observation Report and submit to Architect for posting by Architect of deficiencies on the Wal-Mart Observation Log. Observation Report will indicate the following: 1. Store number and location. 2. Time and date of observaton. 3. Name and contact information of Manufacturer’s Technical Representative. 4. Summary of observation. 5. Identification of deficiencies describing precise door number, hardware item, nature of deficiency, and

recommended resolution. 6. Signature of Manufacturer’s Technical Representative.

3.4 ADJUSTING

A. Hardware Adjustment: Adjust hardware for proper operation and function one month after Substantial Completion. Instruct Owner’s personnel in proper maintenance and adjustment.

Page 22: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-11

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

3.5 HARDWARE SCHEDULE

A. Hardware Set numbers below correspond to the Door Schedule as shown on the drawings.

B. Any hardware item specified in the Tables in Part 2 above which corresponds to the mark associated with the item ( E.g. H-1, E-2, etc.) as shown in the Hardware Schedule below may be provided.

Page 23: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-12

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

Door 100A - Sales: Aluminum/Glass, Bi-Parting Automatic w/ Breakaway – EXISTING TO REMAIN 1 ea. L-1 Keyed Cylinder 1 ea. Locking Device See Section 08462. All other hardware furnished by door manufacturer as specified in Section 08462. Door 100B - Sales: Aluminum/Glass, Bi-Parting Automatic w/ Breakaway – EXISTING TO REMAIN 1 ea. L-1 Keyed Cylinder 1 ea. Locking Device See Section 08462. All other hardware furnished by door manufacturer as specified in Section 08462. Door 100C - Sales: HM, Pair, Exterior w/ Exit Device 3 pr. H-11 Butts 2 ea. E-2 Alarm Exit Device 2 ea. T-9 Threshold 2 ea. W-3 Door Bottom Weatherstrip 2 set W-9 Jamb & Head Weatherstrip 1 ea. M-9 Drip Cap Door 100D - Sales: HM, Pair, Exterior w/ Exit Device 3 pr. H-11 Butts 2 ea. E-1 Exit Device 1 ea. M-11 Door Alarm 1 ea. L-2 Cylinder for Alarm 1 ea. C-7 Closer 2 ea. T-9 Threshold 2 ea. W-3 Door Bottom Weatherstrip 1 set W-5 Door Gaskets 1 ea. M-9 Drip Cap Door 101A - Customer Service: Café Traffic, Single Hardware furnished by door manufacturer as specified in Section 08383. Door 102A - Cash Room: HM, Single 1 ea. H-7 Continuous Geared Hinge 1 ea. L-12 Storeroom Lock with Deadbolt 1 ea. C-4 Closer 3 ea. M-8 Silencers 1 ea. S-1 Wall Stop 2 ea. M-4 One-Way Viewer mount 1 ea @ 48” & 60” AFF 1 ea. M-14 Mail Slot 1 ea. K-2 Kick Plate

SET 103A Door 103A - Women: (HM, Single) 1 ea. (H-7) Continuous Geared Hinge Sel SL21 SD x SDTF x FDH CL 1 ea. (P-1) Push I 8200 630 1 ea. (P-2) Pull I 8314-5 630 1 ea. (C-4) Closer LCN 4011-REG 689 3 ea. (M-8) Silencers I SR64 1 ea. (K-3) Armor Plate I 8400 34" x (DW-2") 630 1 ea. (S-7) Stop and Holder I 452

3

Page 24: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-13

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

SET 104A

Door 104A - Men: (HM, Single) 1 ea. (H-7) Continuous Geared Hinge Sel SL21 SD x SDTF x FDH CL 1 ea. (P-1) Push I 8200 630 1 ea. (P-2) Pull I 8314-5 630 1 ea. (C-4) Closer LCN 4011-REG 689 3 ea. (M-8) Silencers I SR64 1 ea. (K-3) Armor Plate I 8400 34" x (DW-2") 630 1 ea. (S-7) Stop and Holder I 452 Door 105A – Family Toilet: HM, Single 1 ea. H-7 Continuous Geared Hinge 1 ea. L-18 Privacy Lock 1 ea. C-4 Closer 3 ea. M-8 Silencers 1 ea. K-3 Armor Plate 1 ea S-1 Wall Stop 1 ea. S-7 Stop and Holder Door 106A - UPC: HM, Single 1 ea. H-7 Continuous Geared Hinge 1 ea. L-6 Office Lock 1 ea. C-11 Closer 3 ea. M-8 Silencers 1ea. K-2 Kick Plate Door 107A - Manager’s Office: HM, Single 1 ea. H-7 Continuous Geared Hinge 1 ea. L-6 Office Lock 1 ea. C-10 Closer 1 ea. S-1 Wall Stop 3 ea. M-8 Silencers 1ea. K-2 Kick Plate Door 108A – Training: HM, Single 1 ea. H-7 Continuous Geared Hinge 1 ea. L-6 Office Lock 1 ea. C-9 Closer 3 ea. M-8 Silencers 1 ea. K-2 Kick Plate 1 ea. S-1 Wall Stop Door 109A - Breakroom: HM, Single 1 ea. H-7 Continuous Geared Hinge 1 ea. P-1 Push 1 ea. P-2 Pull 1 ea. C-8 Closer 1 ea. S-1 Wall Stop 3 ea. M-8 Silencers 1 ea. K-2 Kick Plate

Page 25: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-14

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

Door 110A - Site to Store: HM, Single 1 ea. H-7 Continuous Geared Hinge 1 ea. L-5 Storeroom Lock 1 ea. C-9 Closer 1 ea. K-3 Armor Plate 3 ea. M-8 Silencers Door 111A - Corridor: HM, Pair, Exterior w/ Exit Device 3 pr. H-11 Butts 2 ea. E-2 Alarm Exit Device 2 ea. T-9 Threshold 2 ea. W-3 Door Bottom Weatherstrip 2 set W-9 Jamb & Head Weatherstrip 1 ea. M-9 Drip Cap Door 112A - Pharmacy: HM, Single 1 ea. H-7 Continuous Geared Hinge 1 ea. L-15 Entrance Lock w/ Deadbolt 1 ea. C-4 Closer 2 ea. M-8 Silencers 2 ea. K-2 Kick Plate Door 112B - Pharmacy: Overhead Rolling Closure Hardware furnished by door manufacturer as specified in Section 08332. Door 114A – Pharmacy Toilet: HM, Single 1 ea. H-7 Continuous Geared Hinge 1 ea. L-18 Privacy Lock 1 ea. C-11 Closer 3 ea. M-8 Silencers Door 119A - Stockroom: Full Height Traffic, Pair Hardware furnished by door manufacturer as specified in Section 08383. Door 119B - Stockroom: HM, Single, w/ Exit Device, Exterior 1-1/2 pr. H-11 Butts 1 ea. E-2 Alarm Exit 2 ea. M-4 One-Way Viewer mount 1 ea @ 48” & 60” AFF 1 ea. T-9 Threshold 1 ea. W-3 Door Bottom Weatherstrip 1 set W-9 Jamb & Head Weatherstrip 1 ea. M-9 Drip Cap Door 120A - Receiving: Full Height Traffic, Pair Hardware furnished by door manufacturer as specified in Section 08383.

Page 26: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-15

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

Door 120B - Receiving: HM, Single, w/ Exit Device, Exterior 1-1/2 pr. H-11 Butts 1 ea. E-2 Alarm Exit 2 ea. M-4 One-Way Viewer mount 1 ea @ 48” & 60” AFF 1 ea. T-9 Threshold 1 ea. W-3 Door Bottom Weatherstrip 1 set W-9 Jamb & Head Weatherstrip 1 ea. M-9 Drip Cap Door 120C - Receiving: Sectional Overhead Hardware furnished by door manufacturer as specified in Section 08360. Door 120D - Receiving: Sectional Overhead Hardware furnished by door manufacturer as specified in Section 08360. Door 120E - Receiving: Sectional Overhead Hardware furnished by door manufacturer as specified in Section 08360. Door 121A - Electrical: HM, Single, w/ Exit Device 1-1/2 pr. H-11 Butts 1 ea. E-2 Alarm Exit Device w/mortise cylinder and removable core 1 ea. T-9 Threshold 1 ea. W-3 Door Bottom Weatherstrip 1 set W-9 Jamb & Head Weatherstrip 1 ea. M-9 Drip Cap Door 121B – Electrical: HM, Single 1 ea. H-7 Continuous Geared Hinge 1 ea. E-16 Exit Device 1 ea. L-3 Rim Cylinder 1 ea. C-11 Closer 3 ea. M-8 Silencers 1 ea. K-2 Kick Plate Door 122A - Mechanical: HM, Single 1 ea. H-7 Continuous Geared Hinge 1 ea. C-11 Closer 1 ea. L-5 Storeroom Lock 3 ea. M-8 Silencers 1 ea. K-2 Kick Plate Door 143A - Produce Prep: Full Height Traffic, Pair Hardware furnished by door manufacturer as specified in Section 08383. Door 148A – Bakery Prep: Full Height Traffic, Single Hardware furnished by door manufacturer as specified in Section 08383. Door 149A – Service Deli: Café Traffic, Single Hardware furnished by door manufacturer, Section 08383.

3

Page 27: REV #1 – 10/11/12, ADD #3 – 11/05/12 · excavation sidewalls and of resisting earth and hydrostatic pressures and superimposed and ... space with compacted backfill. END …

ADD #3 – 11/05/12

08710-16

Milwaukie, OR #3144 1122210 July 30, 2012 ADD #3 – 11/05/12

Door 998A –Fire Riser: HM, Single, Interior 1 ea. H-7) Continuous Geared Hinge 1 ea. L-17 Storeroom Lock 1 ea. S-1 Wall Stop 3 ea. M-8 Silencers 1 ea. C-7 Closer 1 set M-5 Extension Flush Bolts 1 pr. W-4 Meeting Style Gaskets Door 999A - Refrigeration: HM, Pair 2 ea. H-7 Continuous Geared Hinge 1 ea. L-17 Storeroom Lock 1 ea. C-7 Closer 2 ea. S-1 Wall Stop 2 ea. M-8 Silencers

END OF SECTION

3