www.supercriticalfluids.com Innovative Leadership in Supercritical Fluids and High Pressure Chemistry Supercritical Fluid Extractions, Reactions and High Pressure Chemistry www.supercriticalfluids.com SFT-110 Series SFE Systems

SFT-110 Series SFE Systems · The SFT-110 and SFT-110XW utilize the latest variable restrictor valve (back pressure regulator) technology, providing precise control over the flow

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SFT-110 Series SFE Systems · The SFT-110 and SFT-110XW utilize the latest variable restrictor valve (back pressure regulator) technology, providing precise control over the flow

www.supercriticalfluids.com

Innovative Leadership in Supercritical Fluids and High Pressure Chemistry

Supercritical Fluid Extractions, Reactions and High Pressure Chemistry www.supercriticalfluids.com

SFT-110 Series SFE Systems

Page 2: SFT-110 Series SFE Systems · The SFT-110 and SFT-110XW utilize the latest variable restrictor valve (back pressure regulator) technology, providing precise control over the flow

Supercritical Fluid Extractions, Reactions and High Pressure Chemistry www.supercriticalfluids.com

SFT-110 SFT-110XW Unit

One Innovation Way • Newark, DE 19711 • 302-738-3420 • Fax 302-738-4320 • www.supercriticalfluids.com

Bench Top SFE for Universities and Industry

• SampleVesselVolumesfrom5mlto100ml

• Upto500mlandDualorQuadVesselConfigurationforSeriesorParallelOperationintheSFT-110XW

• Operationupto10,000psi(68.9MPa)/200°C

• PIDControlofPressureandTemperature

• IntegratedFluidPreheaterandOptionalFlowMeter

• VariousExtractCollectionOptions

• OptionalCo-solventAdditionModules

The SFT-110 and SFT-110XW Supercritical Fluid Extractors(SFE) are entry level systems which possess many featurestypically found in more costly SFE equipment. They may beusedforavarietyofapplicationsfrombasicresearchtoprocessdevelopment.

These SFE systems were developed for researchers whowant to investigate the feasibility of applying supercriticalfluid techniques to awide variety of analytical and processingproblems.Inadditiontonumerousindustrialuses,theSFT-110andSFT-110XWareidealforcollegesanduniversities.Theyareaffordableforteachinglaboratoriesandwell-suitedtotheneedsoftheseriousresearcher.

TheSFT-110accommodates5mlto100mlextractionvessels.Itmaybeoperatedatpressuresupto10,000psi.(68.9MPa)andattemperaturesrangingfromambientto200°C.

The SFT-110XW accomodates 5 ml to 500 ml extractionvessels. It may be operated at pressures up to 10,000 psi.(68.9 MPa) and at temperatures ranging from ambient to200°C.ItispossibletoconfiguretheSFT-110XWwiththewiderange of vessels volumes making the SFT-110XW well-suitedto both analytical scale SFE applications and basic processdevelopmentwork.Witha500mlvessel, theSFT-110XWcanextract very low levels of key components frommaterials andprocesslargeramountsofbulkmaterialthanwouldbepossiblewithsmaller,analyticalscaleSFEequipment.Forevengreaterversatility,theSFX-110XWmaybeconfiguredfordualvessels,inseriesorparralleloperation.

Inside the SFT-110 series’ oven, a preheater ensures thatthe temperature of the fluid reaching the extraction vessel(s)is controlled precisely. This is essential to obtaining accurate,repeatableresults.

Both the SFT-110 and SFT-110XW incorporate the SFT-10high performance, dual piston carbon dioxide pump whichproducesthehighpressuresrequiredforsupercriticalfluidwork.Thepumphasbuilt-insafetyprecautions topreventaccidentalover-pressure conditions. As an additional safety backup, arupture disc assembly provides mechanical protection againstaccidentalover-pressurizationofthesystem.

Manuallyoperatedvalvesensurelongterm,maintenancefreeoperation. An integratedprogramlogiccontrollermonitorsandadjusts the fluid flow rate to achieve and maintain a desiredpressuresetpoint. APID temperaturecontrollermonitorsandmaintains precise fluid temperature inside the high pressurevessel.

The SFT-110 and SFT-110XW utilize the latest variablerestrictor valve (back pressure regulator) technology, providingprecisecontrolover theflowrateof theexpandinggas.This isessential for obtaining highly reproducible results. Flow ratescan range from 0.01 to 24ml/min (0.008 to 18 grams/min) ofliquidCO2undertypicaloperatingconditions.

Extractcollectionoptionsinclude:solidphaseextraction(SPE)cartridges, solvent filled vessels, fractional cyclone separators,andEPAsamplevials.Optionalco-solventadditionmodulesareavailablefortheSFT-110andSFT-110XW.Forgreaterversitilityandeaseofuse,samplebags,samplebasketsandflowmetersarerecommended.

Page 3: SFT-110 Series SFE Systems · The SFT-110 and SFT-110XW utilize the latest variable restrictor valve (back pressure regulator) technology, providing precise control over the flow

SFT-110 Series System SpecificationsStandard ConfigurationTemperature and Pressure Display:IndependentLEDdisplays.

Temperature Range:Ambientto200°C.Temperature Precision:+/-0.5°C.Operating Pressure:10,000psiupperpressurelimit.Frontkeypadcontrol,withLEDdisplay.Constantpressuremodeofoperation.

Flow Rates:0.01–24.00ml/minliquidCO2(+/-2%accuracy).

Over Pressure Safeguard:High/Lowpressurealarmsandrupturediscassembly.

SFT-10 High Pressure Pump:Dualaluminumheads,furonsealsandsapphirepistons,integratedthermoelectriccooling,cam-drivenpumpmechanismwithsinglesteppermotordive,dualballandseatcheckvalves(rubyball,sapphireseat).Thepump’sconstantpressuremodefeaturesaselectablepressuresetpoint.Flowrateauto-adjuststomaintainpressure.

Restrictor Valve:Heatedupto200°C;Userselectablesetpoint;Resistanttoblockage.

Preheater:Improvestemperatureconsistencyofthefluidbyheatingthefluidbeforeitreachesthemainpressurevessel.

Extraction Vessel:Accommodatesvesselsranginginsizefrom5mlto100ml.(Upto500mlfortheSFT-110XW)Vesselscomewith5micronfritsandareinterchangeable.

Collection Vessel:Externallymounted.Manyoptionsavailable.

SFT-110 Dimensions:Width:29cm,Depth:57cm,Height:76cm.

SFT-110XW Dimensions: Width:40cm,Depth:57cm,Height:102cm

SFT-110 Weight (without vessel):24kg(52lbs)SFT-110XW Weight (without vessel):28kg(60lbs)

Configuration OptionsTheSFE-110XWcanbeconfiguredforadualorquadvesseloptionforseriesorparalleloperation.Co-solvent Addition:Dopingmoduleordirect,in-linemeteredaddition.Interchangable Sample Vessels:5,10,25,50and

100ml.Upto500mlfortheSFT-110XW(Allvesselsincluded5micronfrits)

Sample Baskets:SS,30mesh,withlids.Sample Bags:5MicronNylon,varioussizes.Flow Meter:0-35SLPMofexpandedgas.

System RequirementsPower Requirements:220VAC,50/60HzLiquid Gas Supply:LiquidCO2cylinderwithdiptube.

SFT-110

SFT 25ml Vessel

Page 4: SFT-110 Series SFE Systems · The SFT-110 and SFT-110XW utilize the latest variable restrictor valve (back pressure regulator) technology, providing precise control over the flow

One Innovation Way • Newark, DE 19711 • 302-738-3420 • Fax 302-738-4320 • www.supercriticalfluids.com

P/N:SFT-110/110XW-SPEC 12/15

SAMPLEVESSEL

CO2LIQUID

SUPPLIED BYCUSTOMER

PAH FIC

FAH FIO

TAHTIC

TAHTIC

CO-SOLVENTADDITION

PREHEATCOIL

1/16 TO 1/8ADAPTER

1/16 PLUG

RUPTUREDISK

CHECKVALVE

4X CHECKVALVE

OVEN

STATIC/DYNAMICVALVE

HEATED VARIABLERESTRICTOR VALVE

30ccCOLLECTION

VIAL

FLOWMETER GAS

CO2

OPTIONAL

VENTSFT-110XW SFESingle VesselConfiguration

SFT-110XWTHIS DRAWING IS THE PROPERTY OF SFT CORPORATION,IT IS LOANED AND ACCEPTED ON THE EXPRESS CONDITIONS THATIT WILL BE TREATED AS CONFIDENTIAL INFORMATION, THAT IT WILLBE USED ONLY FOR THE PURPOSE FOR WHICH IT IS LOANED, THATIT WILL NOT BE COPIED OR USED IN ANY WAY DETRIMENTAL TO THEINTEREST OF THE COMPANY, AND THAT IT WILL BE RETURNED UPONREQUEST.

TITLE:SINGLE OPERATION

SCALE: DWG NO: 012506 REV: 3

SAMPLEVESSEL

SAMPLEVESSEL

CO2LIQUID

SUPPLIED BYCUSTOMER

PAH FIC

FAH FIO

TAH TIC

TAHTIC

TAHTIC

CO-SOLVENTADDITION

PREHEATCOIL

1/16 TO 1/8ADAPTER

1/16 PLUG

RUPTUREDISK

CHECKVALVE

4X CHECKVALVE

OVEN

STATIC/DYNAMICVALVE

STATIC/DYNAMICVALVE

HEATED VARIABLERESTRICTOR VALVE

HEATED VARIABLERESTRICTOR VALVE

30ccCOLLECTION

VIAL

30ccCOLLECTION

VIAL

FLOWMETER GAS

CO2

FLOWMETER GAS

CO2

OPTIONAL

OPTIONAL

VENT

VENT

SFT-110XW SFEParallel VesselConfiguration

SFT-110XWTHIS DRAWING IS THE PROPERTY OF SFT CORPORATION,IT IS LOANED AND ACCEPTED ON THE EXPRESS CONDITIONS THATIT WILL BE TREATED AS CONFIDENTIAL INFORMATION, THAT IT WILLBE USED ONLY FOR THE PURPOSE FOR WHICH IT IS LOANED, THATIT WILL NOT BE COPIED OR USED IN ANY WAY DETRIMENTAL TO THEINTEREST OF THE COMPANY, AND THAT IT WILL BE RETURNED UPONREQUEST.

TITLE:PARALLEL OPERATION

SCALE: DWG NO: 040906 REV: 3

SAMPLEVESSEL

SAMPLEVESSEL

CO2LIQUID

SUPPLIED BYCUSTOMER

PAH FIC

FAH FIO

TAH TIC

TAHTIC

TAHTIC

CO-SOLVENTADDITION

PREHEATCOIL

1/16 TO 1/8ADAPTER

1/16 PLUG

RUPTUREDISK

CHECKVALVE

4X CHECKVALVE

OVEN

STATIC/DYNAMICVALVE

STATIC/DYNAMICVALVE

HEATED VARIABLERESTRICTOR VALVE

HEATED VARIABLERESTRICTOR VALVE

30ccCOLLECTION

VIAL

30ccCOLLECTION

VIAL

FLOWMETER GAS

CO2

FLOWMETER GAS

CO2

OPTIONAL

OPTIONAL

VENT

VENT

SFT-110XW SFESeries VesselConfiguration

SFT-110XWTHIS DRAWING IS THE PROPERTY OF SFT CORPORATION,IT IS LOANED AND ACCEPTED ON THE EXPRESS CONDITIONS THATIT WILL BE TREATED AS CONFIDENTIAL INFORMATION, THAT IT WILLBE USED ONLY FOR THE PURPOSE FOR WHICH IT IS LOANED, THATIT WILL NOT BE COPIED OR USED IN ANY WAY DETRIMENTAL TO THEINTEREST OF THE COMPANY, AND THAT IT WILL BE RETURNED UPONREQUEST.

TITLE:SERIES OPERATION

SCALE: DWG NO: 041006 REV: 3

SFT-110SFE

Dual SFT-110XW

Inside the Dual SFT-110XW oven