Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph 1 Features and Benefits Pre-aligned, pre-calibrated detector & spectrograph Motorized, individually factory-calibrated systems – out-of-the-box operation and seamless integration to experimental set-ups • Image astigmatism correction Optimized toroidal optics for high density multi-track capabilities • USB 2.0 interface Plug and play connectivity, ideal for laptop operation alongside Andor USB cameras • Motorized, indexed triple grating turret Easily upgradable in-the-field • Dual detector outputs For extended wavelength coverage when combining Andor UV-Visible CCD and InGaAs cameras Compatible with Andor’s range of CCD, ICCD & EMCCD cameras • Wide range of accessories available The ultimate in modular set-up and in-field upgradability, including: - Motorized slits & filter wheel - Microscope interfaces - Shutters - Fibre-optic & lens couplers - Multi-way fibre-optic bundles - Light sources and optics • Monochromator capabilities Extract best optical resolution while allowing use of single point detectors with sensitivity up to 12 μm • Silver-protected coated optics options Most efficient for Near-Infrared detection when used in conjunction with Andor InGaAs cameras and single point detectors InGaAs, PbS, InSb & MCT High resolution and multi-track performance spectrograph The Shamrock 500i is the platform of choice for high resolution measurements with outstanding multi-track capabilities, but without compromise in configuration versatility and ease of use. This rugged platform features a comprehensive range of light coupling accessories and gratings, and combines ideally with Andor’s market leading CCD, Electron Multiplying CCDs, InGaAs and Intensified CCDs. Andor’s latest addition of single point detectors for scanning monochromator applications up to the LWIR (12 μm) enhances even further the capabilities of this system. State-of-the-art Solis Spectroscopy and Solis Scanning software offer a dedicated and intuitive interfaces for spectrograph, detectors and motorized accessory control as well as easy detection parameter set-up. Specifications Summary Resolution with Newton DU940 CCD 1200 l/mm @ 500 nm 2400 l/mm @ 300 nm 0.07 nm 0.03 nm Aperture F/6.5 Focal length 500 mm Magnification (Vertical @ centre of CCD) 1 Gratings Interchangeable indexed triple turret Slit widths range (input/output) Manual or motorized 10 µm to 2.5 mm Communication USB 2.0 Wavelength accuracy 0.04 nm Wavelength repeatability 10 pm Spectroscopy

Shamrock 500i Czerny-Turner Spectrograph - Tokyo Inst · Czerny-Turner spectrographs are designed to provide the best optical performance for a range of grating angles as reflected

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    1

    Features and Benefits

    • Pre-aligned, pre-calibrated detector & spectrograph Motorized, individually factory-calibrated systems – out-of-the-box operation and seamless integration to experimental set-ups

    • Image astigmatism correction Optimized toroidal optics for high density multi-track capabilities

    • USB 2.0 interface Plug and play connectivity, ideal for laptop operation alongside Andor USB cameras

    • Motorized, indexed triple grating turret Easily upgradable in-the-field

    • Dual detector outputs For extended wavelength coverage when combining Andor UV-Visible CCD and InGaAs cameras Compatible with Andor’s range of CCD, ICCD & EMCCD cameras

    • Wide range of accessories available The ultimate in modular set-up and in-field upgradability, including:

    - Motorized slits & filter wheel - Microscope interfaces - Shutters - Fibre-optic & lens couplers - Multi-way fibre-optic bundles - Light sources and optics

    • Monochromator capabilities Extract best optical resolution while allowing use of single point detectors with sensitivity up to 12 μm

    • Silver-protected coated optics options Most efficient for Near-Infrared detection when used in conjunction with Andor InGaAs cameras and single point detectors InGaAs, PbS, InSb & MCT

    High resolution and multi-track performance spectrograph

    The Shamrock 500i is the platform of choice for high resolution measurements with

    outstanding multi-track capabilities, but without compromise in configuration versatility

    and ease of use. This rugged platform features a comprehensive range of light coupling

    accessories and gratings, and combines ideally with Andor’s market leading CCD,

    Electron Multiplying CCDs, InGaAs and Intensified CCDs. Andor’s latest addition

    of single point detectors for scanning monochromator applications up to the LWIR

    (12 μm) enhances even further the capabilities of this system. State-of-the-art Solis

    Spectroscopy and Solis Scanning software offer a dedicated and intuitive interfaces

    for spectrograph, detectors and motorized accessory control as well as easy detection

    parameter set-up.

    Specifications SummaryResolution with Newton DU940 CCD

    1200 l/mm @ 500 nm

    2400 l/mm @ 300 nm

    0.07 nm

    0.03 nm

    Aperture F/6.5

    Focal length 500 mm

    Magnification

    (Vertical @ centre of CCD) 1

    Gratings Interchangeable indexed triple turret

    Slit widths range (input/output) Manual or motorized 10 µm to 2.5 mm

    Communication USB 2.0

    Wavelength accuracy 0.04 nm

    Wavelength repeatability 10 pm

    Spectroscopy

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    2

    Step-by-Step System ConfigurationHow to customize the Shamrock 500i:

    Step 1.Chassis

    configuration

    Step 3.Input light

    coupling interfaces

    Step 4.2nd output portconfiguration

    Step 2.Resolution

    &band-pass

    a) Select combination of input and output ports (see page 3 for available options). b) Select type of optics coating required (aluminium + MgF2 is standard, protected silver coated optics available on request for NIR detection). c) Select purge port option (for improved detection down to 180 nm), and shutter for background acquisition and detectors protection.

    Step 1. - Chassis configuration

    a) Select the appropriate Shamrock spectrograph platform, giving due consideration to bandpass and spectral range requirement. b) Select gratings and detector to fulfil resolution requirements. c) Select gratings for suitable wavelength coverage.

    Step 2. - Resolution & band-pass

    Refer to accessory tree for available configurations (direct coupling, fibre coupling or 3rd party hardware connectivity).

    Step 3. - Input light coupling interface

    Select either state-of-the-art Solis software or Software Development Kit (SDK) option – please refer to appropriate section for further information.

    Step 5. - Software interface

    Refer to accessory tree for available configurations, including camera flanges.

    Step 4. - 2nd exit port configuration

    Side output

    Side input

    Direct output

    Direct input

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    3

    Step 1 - Chassis Configuration

    Model Side inputport

    Direct inputport

    Direct outputport

    Side outputport

    Motorized flipper mirror

    SR-500i-A Manual slit - Camera - -

    SR-500i-B1 Manual slit - Camera Manual slit √

    SR-500i-B2 Manual slit - Camera Camera √

    SR-500i-C Manual slit Manual slit Camera - √

    SR-500i-D1 Manual slit Manual slit Camera Manual slit √

    SR-500i-D2 Manual slit Manual slit Camera Camera √

    SR-500i-XX-SIL Protected silver coated optics options for models shown above (replace X with relevant model number)

    Ordering Information

    Optics Coatings Reflectivity Graph

    The graph shows the standard Al + MgF2 optics

    coatings reflection efficiency versus wavelength.

    Protected silver coated optics option is also

    available on request for maximum efficiency in the

    NIR region and is recommended for working with

    Andor iDus InGaAs detectors or IR single-point

    detectors, such as MCT, PbS and InSb.

    When choosing protected silver coatings, it is

    strongly recommended to also order protected

    silver coated gratings for maximum efficiency

    throughout the system.

    Chassis Accessories

    Purge Connector (SR-ASM-8040)

    USB Cable (Standard)

    Shutters•2 (SR-SHT-9002)

    Additional Grating Turret•1

    (SR-ASM-0085)

    New iStar I2C to BNC shutter cable (ELC-05323)

    75

    80

    85

    90

    95

    100

    200 400 600 800 1000 1200 1400 1600 1800 2000

    Refle

    ctiv

    ity (%

    )

    Wavelength (nm)

    Protected Silver Optics

    Aluminium & MgF2

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    4

    Step 2a - Choosing The Right Platform vs Dispersion Requirements

    Czerny-Turner spectrographs are designed to provide the best optical performance for a range of grating angles as reflected on the green parts of the

    graph above. Outside this range, the spectral lines may exhibit a degree of optical aberration (such as coma), which will become more prominent at the

    steeper angles. These configurations are reflected by the orange to red scales on the graph. In these regions, consideration should be given to higher

    spectrograph focal length models with lower groove density gratings to achieve the desired resolution.

    Grating (l/mm)

    Shamrock 193 150 300 600 1200 1800 (Holo) 2400 (Holo)

    Bandpass (nm)•3,•5 902 445 215 98 56 46•6

    Resolution (nm)•4,•5 1.96 0.96 0.47 0.21 0.12 0.10•6

    Shamrock 303i

    Bandpass (nm)•3,•5 600 297 144 67 39 32•6

    Resolution (nm)•4,•5 0.88 0.43 0.21 0.10 0.06 0.05•6

    Shamrock 500i

    Bandpass (nm)•3,•5 357 177 86 40 26 19•6

    Resolution (nm)•4,•5 0.52 0.26 0.13 0.06 0.04 0.03•6

    Shamrock 750

    Bandpass (nm)•3,•5 242 120 59 28 18 14•6

    Resolution (nm)•4,•5 0.35 0.18 0.09 0.04 0.03 0.02•6

    Where aberration is a concern for a particular experimental set-up, the table above shows resolution and band-pass performance for a variety

    of alternative configurations. This should be used in conjunction with the graph above to assist in selecting the most appropriate Shamrock

    spectrograph platform to meet resolution and band-pass needs, whilst minimising the risk of potential aberration.

    Green

    Aberration-free region

    Orange

    Possible impact on

    system resolution

    Red

    Likely impact on system

    resolution

    Resolution calculator

    andor.com/calculators

    http://www.andor.com/ResolutionCalculator.aspxhttp://www.andor.com/spectroscopy_solutions/calculator/

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    5

    Step 2b - Choosing The Right Grating vs Resolution & Band-pass

    The Shamrock 500i features an innovative triple grating turret, designed to offer flexibility and control over your choice and

    interchange of gratings. The triple grating turret can be easily and speedily removed, and replaced by an alternative turret

    with new gratings. The intelligent design of the 500i means that only a simple offset adjustment is required once the new

    turret and gratings are added. The 500i is shipped with the grating turret already in place, ensuring your system is ready

    for use straight out of the box. Additional grating turrets are available with up to three pre-installed gratings (see below for

    details). If the grating you require is not on the list, please contact Andor for further details. Additional grating turrets (part

    number SR-ASM-0085) can also be supplied on request.

    Lines/mm

    Blaze (nm) Nominal

    dispersion(nm/mm)•7

    Bandpass(nm)•3,•7

    Resolution (nm)•4,•7,•10

    Peak efficiency

    (%)

    Andor part number

    Maximum recommended

    wavelength (nm)

    Maximum attainable

    wavelength (nm)

    150 300 12.96 358 0.53 72 SR5-GRT-0150-0300

    6915 11310

    150 500 12.91 357 0.52 73 SR5-GRT-0150-0500

    150 800 12.83 355 0.52 80 SR5-GRT-0150-0800

    150 1250 12.69 351 0.51 84 SR5-GRT-0150-1250

    150 2000 12.43 344 0.50 88 SR5-GRT-0150-2000

    300 300 6.44 178 0.26 88 SR5-GRT-0300-0300

    3460 5655

    300 500 6.38 177 0.26 81 SR5-GRT-0300-0500

    300 1000 6.20 172 0.25 72 SR5-GRT-0300-1000

    300 1200 6.14 170 0.25 92 SR5-GRT-0300-1200

    300 1700 5.92 164 0.24 89 SR5-GRT-0300-1700

    600 300 3.18 88 0.13 84 SR5-GRT-0600-0300

    1730 2830

    600 500 3.11 86 0.13 72 SR5-GRT-0600-0500

    600 1000 2.88 80 0.12 72 SR5-GRT-0600-1000

    600 1200 2.77 77 0.11 88 SR5-GRT-0600-1200

    6001900 2.24 62 0.09•9

    88 SR5-GRT-0600-1900(@1600)•8 2.49 69 0.10

    1200 300 1.54 42 0.06 72 SR5-GRT-1200-0300

    865 1415

    1200 500 1.44 40 0.06 81 SR5-GRT-1200-0500

    12001000 1.07 30 0.05•9 69

    SR5-GRT-1200-1000(@ 800)•8 1.25 34 0.05 69

    1200 Holographic (500 nm peak) 1.44 40 0.06 81 SR5-GRT-1200-EH*

    1800 Holographic (250 nm peak) 1.00 28 0.04 62 SR5-GRT-1800-DH575 945

    1800 Holographic (380 nm peak) 0.93 26 0.04 70 SR5-GRT-1800-FH

    2400 300 0.69 19 0.03 68 SR5-GRT-2400-0300

    435 7052400Holographic

    (220 nm peak) 0.74 20 0.03 68 SR5-GRT-2400-BH

    2400 Holographic (400 nm peak) 0.62 17 0.03 73 SR5-GRT-2400-GH

    Mirror UV-VIS - - - SR5-GRT-MR-AL-MGF2- -

    Mirror VIS-NIR - - - SR5-GRT-MR-SILVER

    *Option for minimized scattered light.

    Need to have maximum collection efficiency in the NIR/SWIR? All gratings are also available with protected silver

    coating. Please contact your local representative for further information.

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    6

    Step 2c - Selecting The Correct Grating Efficiency Option All graphs shown below represent efficiency for 45° polarisation

    405060708090

    100

    cien

    cy (%

    )

    600 l/mm - Ruled

    1200 nm

    1900 nm300 nm

    1000 nm

    500 nm

    0102030405060

    200 500 800 1100 1400 1700 2000 2300

    Effic

    ienc

    y

    Wavelength (nm)

    1000 nm

    405060708090

    100

    cien

    cy (%

    )

    150 l/mm - Ruled

    1250 nm 2000 nm

    300 nm800 nm

    0102030405060

    200 500 800 1100 1400 1700 2000 2300

    Effic

    ienc

    y

    Wavelength (nm)

    500 nm

    405060708090

    100

    cien

    cy (%

    )

    300 l/mm - Ruled

    1200 nm

    1700 nm

    300 nm500 nm

    0102030405060

    200 500 800 1100 1400 1700 2000 2300

    Effic

    ienc

    y

    Wavelength (nm)

    1000 nm

    5060708090

    100

    ncy

    (%)

    1200 l/mm - Ruled & Holographic

    300 nm

    1000 nm

    Holographic (EH)Optimised for 360 - 920 nm500 nm

    010203040506070

    200 400 600 800 1000 1200 1400 1600 1800

    Effic

    ienc

    y (%

    )

    Wavelength (nm)

    1000 nm

    200 400 600 800 1000 1200 1400 1600 1800Wavelength (nm)

    405060708090

    100

    cien

    cy (%

    )

    2400 l/mm - Ruled & Holographic

    Holographic (GH)Optimised for 250 - 800 nm

    Holographic (BH)Optimised for 190 - 800 nm

    0102030405060

    200 350 500 650 800 950

    Effic

    ienc

    y

    Wavelength (nm)

    300 nm

    405060708090

    100

    cien

    cy (%

    )

    1800 l/mm - Holographic

    Holographic (FH)Optimised for 360 - 1100 nm

    Holographic (DH)Optimised for 190 - 800 nm

    0102030405060

    200 400 600 800 1000 1200

    Effic

    ienc

    y

    Wavelength (nm)

    Optimised for 190 - 800 nm

    Important ConsiderationSystem throughput is dependent on the grating’s angle of operation and may decrease with higher grating operating angles.

    1730 2100 865 1050 1415

    575 435700 525945 705

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    7

    Step 3 - Selecting The Correct Light Coupling InterfacesHow to customize the Shamrock 500i (Side Entrance Port):

    Spacer (Standard) Filter Wheel Assembly (ACC-SR-ASZ-7005)

    Fixed SMA Fibre Adapter

    (ACC-SR-ASM-8003)

    Motorized Slit Assembly•13

    (SR-ASZ-0035)inc 6 x 4 mm (W x H)

    Cover Plate

    Manual Slit Assembly•13

    (Standard)inc 6 x 4 mm (W x H)

    Cover Plate

    Fixed FC Fibre Adapter

    (SR-ASM-8011)

    Cover Plate for Motorized Slit(See page 10 Section A: Slit Covers)

    Cover Plate for Manual Slit(See page 10 Section A: Slit Covers)

    Neutral Density Filters•12

    Long Pass Filters•12

    Short Pass Filters•12 Raman Edge Filters•12

    Side input port (applicable to all models)

    F-Mount Lens•12

    Cage System (Please refer

    to Thorlabs or Linos catalogue)

    F-Mount Camera Lens

    Adapter (SR-ASM-0013)

    Pen-Ray Lamp Mount (SR-ASM-0014)

    Pen-Ray Lamp•12 Hg-Ar, Hg-Ne,

    Ar, Kr, Ne

    1.5” Flange Adapter for Newport Oriel

    Accessories (SR-ASM-0002)

    Optical Cage System Adapter (SR-ASM-0065)

    Cage system microscope flange (TR-XXXX-CAGE-ADP)•12

    C-Mount Adapter (SR-ASM-0021)

    X-Y Adjustable Fibre Adapter(See page 10 Section B:Direct X-Y fibre couplers)

    F/# Matcher for NA = 0.22 Fibre

    (SR-ASM-0039)•11Sample Chamber

    (ACC-SR-ASZ-0056)•12

    X-Y Adjustable Fibre Adapter

    (See page 10 Section C: X-Y fibre couplers with slit assembly)

    Fibre Ferrule (SR-OPT-80XX)•12

    X Adjustable Fibre Adapter, Ferrule Input

    (SR-ASM-8006)

    Fixed Fibre Adapter,Ferrule Input

    (SR-ASM-8001)

    SMA Adapter for F/# Matcher(SR-ASM-0041)

    SMA - SMA Fibre (50 µm: ACC-ME-OPT-8004)

    (100 µm: SR-OPT-8039)

    FC Adapter for F/# Matcher

    (SR-ASM-0064)•12

    C-Mount Lens (OL-XXXX-XXX)•12

    SR-ASZ-0079 Optical Relay

    SMA Fibre (50 µm: ACC-ME-OPT-8004)

    (100 µm: SR-OPT-8039)

    Wide Aperture Slit(SR-ASZ-0086)

    inc Ø27 mm Cover Plate

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    8

    Step 3 - Selecting The Correct Light Coupling InterfacesHow to customize the Shamrock 500i (Direct Entrance Port):

    F-Mount Lens•12

    F-Mount Camera Lens Adapter

    (SR-ASM-0013)

    Pen-Ray Lamp Mount (SR-ASM-0014)

    Pen-Ray Lamp•12 Hg-Ar, Hg-Ne,

    Ar, Kr, Ne

    1.5” Flange Adapter for Newport Oriel

    Accessories (SR-ASM-0002)

    C-Mount Adapter (SR-ASM-0021)

    Motorized Slit Assembly•13

    (SR-ASZ-0032)inc 6 x 4 mm (W x H)

    Cover Plate

    Manual Slit Assembly•13

    (Standard)inc 6 x 4 mm (W x H)

    Cover Plate

    Cover Plate for Motorized Slit(See page 10 Section A: Slit Covers)

    Cover Plate for Manual Slit(See page 10 Section A: Slit Covers)

    Direct input port (applicable to C & D models)

    X-Y Adjustable Fibre Adapter(See page 10 Section B:Direct X-Y fibre couplers)

    F/# Matcher for NA = 0.22 Fibre

    (SR-ASM-0039)•11

    X-Y Adjustable Fibre Adapter

    (See page 10 Section C: X-Y fibre couplers with slit assembly)

    Fibre Ferrule (SR-OPT-80XX)•12

    X Adjustable Fibre Adapter, Ferrule Input

    (SR-ASM-8006)

    Fixed Fibre Adapter,Ferrule Input

    (SR-ASM-8001)

    SMA Adapter for F/# Matcher(SR-ASM-0041)

    SMA - SMA Fibre (50 µm: ACC-ME-OPT-8004)

    (100 µm: SR-OPT-8039)

    FC Adapter for F/# Matcher

    (SR-ASM-0064)•12

    C-Mount Lens (OL-XXXX-XXX)•12

    SR-ASZ-0079 Optical Relay

    Wide Aperture Slit(SR-ASZ-0095)

    inc Ø27 mm Cover Plate

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    9

    Step 4 - Cameras & Output Port FlangesHow to customize the Shamrock 500i:

    Direct Detector Output Port

    iKon-M Mounting Flange (MFL-SR500-IKON-M)•15

    iXon ULTRA Mounting Flange (MFL-SR500-IXON)•15

    Output Port Motorized Slit Assembly•13

    (SR-ASZ-0036)inc 6 x 4 mm (W x H)

    Cover Plate

    Manual Adjustable Slit Assembly•13

    (Standard)inc 6 x 4 mm (W x H)

    Cover Plate

    Manual AdjustableSlit Assembly•13

    (SR-ASZ-0030)inc 6 x 4 mm (W x H)

    Cover Plate

    Multi-channel Detector Flange to Slit Adapter Plate•14

    (SR-ASM-0062)

    Multi-channel Detector Flange

    (MFL-SR500)

    (To be ordered separately,

    2 flanges required per -B2

    and D2 models)

    Cover Plate for Motorized Slit Assembly(See page 10 Section A:

    Slit Covers)

    Cover Plate for Manual Adjustable Slit Assembly

    (See page 10 Section A: Slit Covers)

    Cover Plate for Manual Adjustable Slit Assembly

    (See page 10 Section A: Slit Covers)

    Sample Chamber (ACC-SR-ASZ-0056)•12

    C-Mount Adapter (SR-ASM-0021)

    Please refer to the dedicated “Scanning Monochromator

    Accessories” Specifications Sheet

    Scanning Monochromator

    Accessories

    Side Output Port (Applicable to B & D models)

    X-Y Adjustable Fibre Adapter(See page 10 Section B:Direct X-Y fibre couplers)

    X-Y Adjustable Fibre Adapter,(See page 10 Section B:Direct X-Y fibre couplers)

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    10

    Cover Plate Apertures for Motorized Slit

    Part No. Size

    SR-ASM-0016•16 6 x 4 mm (W x H)

    SR-ASM-0017 6 x 6 mm (W x H)

    SR-ASM-0010 6 x 8 mm (W x H)

    SR-ASM-0011 6 x 14 mm (W x H)

    SR-ASM-0015•17 Ø 15 mm

    Cover Plate Apertures for Manual Slit

    Part No. Size

    SR-ASM-0025 6 x 4 mm (W x H)

    SR-ASM-0026 6 x 6 mm (W x H)

    SR-ASM-0027 6 x 8 mm (W x H)

    SR-ASM-0028 6 x 10 mm (W x H)

    SR-ASM-0029•16 6 x 14 mm (W x H)

    SR-ASM-0067•17 Ø 15 mm

    A: Slit Covers

    Fibre Ferrule (SR-OPT-80XX)•12

    FC: SR-ASM-8056•12 SMA: SR-ASM-8052

    Ferrule SR-ASM-8069

    SMA - SMA Fibre (50 µm: ACC-ME-OPT-8004)

    (100 µm: SR-OPT-8039)

    FC upgrade: ACC-FC-SLIT-APTSMA upgrade: ACC-SMA-SLIT-APTFerrule upgrade: ACC-FERRULE-SLIT-APT

    C: X-Y Fibre Couplers (with Slit Assembly)

    FC: SR-ASM-8053•12

    FC-APC: SR-ASM-8055•12

    SMA: SR-ASM-8054

    FC upgrade: ACC-FC-DIRECT-APTFC/APC upgrade: ACC-FCAPC-DIRECT-APT

    SMA upgrade: ACC-SMA-DIRECT-APT

    Fibre Ferrule (SR-OPT-80XX)•12

    SMA - SMA Fibre (50 µm: ACC-ME-OPT-8004)

    (100 µm: SR-OPT-8039)

    Ferrule: SR-ASM-8057

    B: Direct X-Y Fibre Couplers

    Notes:• For connection to manual slits, please also order Ø15 mm slit cover plate SR-ASM-0067

    • For connection to motorized slits, please also order Ø15 mm slit cover plate SR-ASM-0015

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    11

    The Shamrock 500i requires at least one of the following software options:

    1 - Solis Spectroscopy A 32-bit and fully 64-bit enabled application for Windows (XP, Vista, 7 and 8) offering rich functionality for data acquisition and

    processing, as well as Andor cameras, spectrograph and motorized accessories simultaneous control. AndorBasic provides macro language control of

    data acquisition, processing, display and export.

    2 - Standalone Solis Spectroscopy GUI for standalone spectrograph operation

    3 - Shamrock SDK A software development kit that allows you to control the Andor range of Shamrock spectrographs from your own application.

    Compatible as 32 bit libraries for Windows (XP, Vista, 7 and 8). Compatible with C/C++, C#, VB6 and LabVIEW and Linux.

    4 - Solis Scanning Dedicated interface for scanning monchromator acquisitions, including comprehensive experimental set-ups builder. Simultaneous

    control of single point detector Shamrock monochromator and motorized accessories.

    Step 5 - Selecting A Software Option

    (a) Slit drive: Control the spectrograph slit width - drag blades on icon or type in required slit width(b) Flipper motor: Used to select the appropriate exit port(c) Shutter: Synchronization mode selection for shutter operation(d) Filter wheel: Used to select a particular filter on the filter wheel - just click on the desired filter position(e) Grating turret: Used for setting grating turret to a new position and bringing desired grating in the optical path - just click on the desired grating

    Real Time Control

    (a) (b) (c) (d) (e)

    Set the exposure time for the detector - quick access for easy acquisition optimization

    Set the wavelength range for the current grating - drag slider to desired wavelength or just type in appropriate value

    Solis Spectroscopy: Dedicated spectroscopy acquisition software

    Exposure time

    Wavelength drive

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    12

    Optical Axis

    The optical path height is shown with standard feet attached.

    Product DrawingsDimensions in mm [inches]

    10.0 [0.39]Focal Plane

    84.0

    [23.39]

    [3.31]

    [8.1

    4]20

    6.6

    146

    [5.7

    5]

    594.1

    550.0 [21.65]

    Opt

    ical

    Hei

    ght

    Opt

    ical

    Hei

    ght

    4 offMounting Holes6x32 UNC

    [11.34]

    [3.54]90.0

    288.0 [2.75]

    146

    [5.7

    5]

    70.0

    52.0

    [2.0

    5]

    323.0 [12.72]

    Connecting to the Shamrock 500i

    USB Shamrock Control

    Connector type: USB ‘B’ type

    Shutter Control

    Connector type: BNC Female, 50 Ω

    Typical Setup - Spectroscopy

    Alternative Detector

    (e.g. iDus InGaAs)

    PC

    Software CDLamp

    Newton EMCCD

    Shamrock 500i Spectrograph

    Lens

    Shutter SpecificationsMaximum repetition rate 2 Hz

    Minimum open/close time 15 ms

    Minimum lifetime Better than 100K cycles

    Optical PropertyFocal plane size (mm, W x H) 30 x 14

    Stray light •18

    FVB (1 nm from laser)FVB (10 nm from laser)

    1 mm strip (1 nm from laser)1 mm strip (10 nm from laser)

    1.1 x 10-4

    2.6 x 10-5

    1.1 x 10-4

    2.6 x 10-5

    Applications Guide

    Screw Type Requirements

    CCD flange to Spectrograph flange 4 off, M4 x 16

    Camera to CCD flange 4 off, M3 x 10

    iXon camera to iXon flange 4 off, M5 x 10, countersunk, hex head

    Third-angle projection

    Wavelength Drive PerformanceWavelength accuracy •19

    Center 0.04 nm

    Wavelength repeatability •20 10 pm

    Wavelength Side AccuracyWavelength side accuracy •21 0.05 nm

    Weight: 25 kg [55.12 lbs approx]

    Absorption-Transmission-Reflection

    Raman (Stimulated, Resonance, CARS, SERS, SORS, TERS)

    Fluorescence-Luminescence

    Single Molecule Spectroscopy

    Plasma Studies & LIBS

    Plasmonics

  • Shamrock 500i 500 mm focal length, motorized, Czerny-Turner Spectrograph

    13

    Minimum Computer Requirements:

    • 3.0 GHz single core or 2.4 GHz multi core processor

    • 2 GB RAM

    • 100 MB free hard disc to install software (at least

    1 GB recommended for data spooling)

    • USB 2.0 High Speed Host Controller capable of

    sustained rate of 40 MB/s

    • Windows (XP, Vista, 7 and 8)

    Operating & Storage Conditions

    • Operating Temperature: 0°C to 30°C ambient

    • Relative Humidity: < 70% (non-condensing)

    • Storage Temperature: -25°C to 50°C

    Power Requirements

    • 100 - 240 VAC 50 - 60 Hz

    Order TodayNeed more information? At Andor we are committed to finding the correct solution for you. With a dedicated team of technical advisors, we are able to offer you one-to-one guidance and technical support on all Andor products. For a full listing of our local sales offices, please see:

    Our regional headquarters are:Europe Japan

    Belfast, Northern Ireland Tokyo

    Phone +44 (28) 9023 7126 Phone +81 (3) 6732 8968

    Fax +44 (28) 9031 0792 Fax +81 (3) 6732 8939

    North America China

    Connecticut, USA Beijing

    Phone +1 (860) 290 9211 Phone +86 (10) 8271 9066

    Fax +1 (860) 290 9566 Fax +86 (10) 8271 9055

    andor.com/contact

    SShamrock500iSS 0615 R1

    Windows is a registered trademark of Microsoft Corporation. Labview is a registered trademark of National Instruments. Matlab is a registered trademark of The MathWorks Inc.

    1x 3 m USB 2.0 cable Type A to Type B

    1x Power supply with 3 m mains cable

    1x CD containing Andor user guides

    1x Individual system performance booklet

    1x CD containing either Solis software or SDK

    (if requested at time of order)

    1x Allen key set (2 mm, 3 mm & 5 mm)

    Items shipped with your spectrograph

    Compliant with the requirements of the EU

    EMC and LVD Directives, compliant with the

    international EMC and safety standards IEC

    61326-1 and IEC 61010-1.

    Regulatory Compliance

    Footnotes: Specifications are subject to change without notice1. In the case of a multiple grating turret order, please specify desired grating configuration for each turret.2. SR-SHT-9002 calls for 1x shutter. For dual input port options (C, D1 & D2) it is recommended to order a

    shutter for each port. Shutter operation only requires BNC to SMB cable from USB cameras or BNC to BNC cable from IO box for PCI iStar.

    3. Typical values quoted with 27.6 mm wide CCD, e.g. Newton DU940. 4. Typical values quoted with 10 μm slit and 13.5 μm pixel CCD, e.g. Newton DU940.5. Typical values quoted at 500 nm centre wavelength.6. Typical values quoted at 300 nm centre wavelength.7. Typical values quoted at maximum efficiency wavelength or blaze wavelength unless otherwise stated.8. Wavelength within the recommended operating spectral region. 9. Indicative values; the working range of these gratings is principally in the region where optical aberrations may alter

    the system resolution performance quoted.10. Values shown are representative of a triple grating system, where resolution has been optimized to give the best

    performance for the three gratings and across the full recommended wavelength range. Useful signal is assumed to be imaged on the entire height of a 6.9 mm sensor (i.e. Newton DU940) and fully vertically binned.

    11. Please refer to F/# matcher specification sheet for magnification considerations.12. Please refer to the local sales representative or website for further information on available options and

    complimentary accessories.13. Slit widths range from 10 μm to 2.5 mm.14. For B2 and D2 configurations only - to be ordered separately.15. Please specify relevant port at time of order.16. Provided as standard.17. Recommended for use with fibre-optics and C-mount accessories.18. Measured with a 633 nm laser and a 1200 l/mm grating for Full Vertical Binning (FVB) on a 6.9 mm high

    sensor, and a 1 mm strip vertically centred on the optical axis.19. Average measurements using > 30 calibration lines, covering the recommended grating angle operating

    range with a 1200 l/mm grating.20. The standard deviation of 20 measurements of a peak’s centre-of-mass position: between each

    measurement the drive is moved 10x including both wavelength and grating changes to reflect typical use.21. Side accuracy measured using a 27.6 mm wide sensor, reflecting the dispersion calibration and step-and-

    glue accuracy.