1
150mm Precast Concrete Hollowcore Floor Slab Has A Span Of 10M Steel Base Plate To Suppport CHS Above 120mm PIR Rigid Insulation Being Used On Ground Level 75mm Self Leveling Stuctural Screed 4mm Mormoleum Floor Finish 300mm Cast Insitu Concrete Column Concrete Infill To Support Drainage Channel 30mm Sand Blinding Beneath Paving 60x100mm Permeable Paving 1:50 Gradient Drainage Channel Used To Drain Water Away From Curtain Walling Hardcore 150mm Corble To Allow Steel BAse Plates To be Fixed To In Term Supporting Structural Glazing Machined stainless Steel Angle Brackets Supporting Structural Glazing 50mm PIR Rigid Insulation USed To Stop Cold Bridging Steel PLate Used To Drain Water Away From Glazing 25mm Sloped Structural Glazing 2400x2400mm Panel Sizes Aluminium Plate used to Hold The Glazing In Place Aluminium Spider Clamp Used To Support The Structural Glazing Suitable Sealant Used To Seal Panels And Make An Airtight Seal 219mm Hot Rolled CHS Secondary Structure To Support Structural Glazing 100mm CHS Acting As A Truss Rod Supporting Steel Rod Which Supports Spider Clamp Steel Rod Acting As A Truss Rod Which Supports Spider Clamp Steel Plate Pivetted To An 8 Degree Slope To Suit Glazing Trench Heating Used To Stop Condensation Occuring On Glazing Intumescent Seal Used For Fire Proporties 150 120 75 4 300 150 52 150 50 25 180 219 25mm Sloped Structural Glazing 2400x2400mm Panel Sizes Aluminium Plate used to Hold The Glazing In Place Aluminium Spider Clamp Used To Support The Structural Glazing Suitable Sealant Used To Seal Panels And Make An Airtight Seal 4mm ACM Panel Used As A Coping For The Parapet 50mm PIR Rigid Insulation Used To Stop Cold Bridging 4mm Aluminium Composite Material Panel Rainscreen Cladding 600x1200mm Panel Size Horizontal Steel Z Bracket Used To Support The Main Cladding Rail 50mm Horizontal Rainscreen Cladding Railing System 180mm Secondary Vertical Cold Rolled Steel Structure @ 600 Centres 12mm Fibre Cement Particle Board Continuing Aroung Steel Frame 3 Degree Slope On ACM Coping To Allow It To Drain Back Onto The Green Roof Hot Rolled Steel Channel Used To Form Upstand On The Parapet 180x250mm Hot Rolled Steel Beam To Be Approved By Structural Engineer Vapour Barrier 150mm Growing Medium 40mm Drainage Layer/Pots 120mm PIR Rigid Insulation 180X250mm Hot Rolled Steel Purlin To Be Approved By Structural Engineer 75mm Self Leveling Stuctural Screed Machined stainless Steel Angle Brackets Supporting Structural Glazing Hot Rolled Steel Channel Used To Form Wall Upstand Removable ACM Panel In Case Glazing Needs To Be Repaired Or Cleaned Intumescent Seal Used For Fire Proporties Vapour Barrier 219mm Hot Rolled CHS Secondary Structure To Support Structural Glazing 100mm CHS Acting As A Truss Rod Supporting Steel Rod Which Supports Spider Clamp Steel Rod Acting As A Truss Rod Which Supports Spider Clamp 3 Degree Slope On ACM Coping To Allow It To Drain Back Onto The Green Roof Protection mat to prevent mechanical damage to the waterproofing system PE Foil Seperator Layer Between The Waterproofing & Green Roof Components Gravel Or Stone 203 250 75 120 40 150 3 Sheet No - 28 Sim 2 Sheet No - 29 Sim 1 Sheet No - 28 Sim 1 Sheet No - 32 Sim Scale LECTURER Drawn by Date Project number As indicated 22/04/2016 20:53:10 Details (11) - Structural Glazing Sloped @ Pharmacy 3 15/03/16 Con Mc Evoy Noel Dunne, Dan O'Sullivan & Mark Duffy Sheet No - 28 1 : 5 Structural Glazing Foundation 1 1 : 5 Structural Glazing W/ Green Roof 3 1 : 20 120 ACM Panel Section 5 Key Plan NTS 6 3D Perspective Rendered View NTS 7 4150 3600 3920 3000 1100mm High Glass Balustrade Provided For Health And Safety Reasons Green Roof Tinted Internal Glass Intermediate Floor Circular Hollow Sections Ground Floor Level ACM Rainscreen Cladding 3000x3000mm Structural Glazing Panels Basement Raft Foundation 300mm Wall Build Up In Basement Internal Partition Wall Section Cut Structural Glazing NTS 4 The Steel Plates And Angled Brackets Protecting And Supporting The Structural Glazing Are Removable So That In The Event Where A Panel Is Broken And Needs To Be Replaced It Is Easy To Do So. This Also Applies To The Top As The Angle Brackets And Cladding Panels Are Removable As To Get Easy Access To Replace The Strucural Glazing. Removable Brackets NTS 8 Removable Cladding Panel NTS 10 Removable Aluminium Base Cover Panels NTS 9 3D Perspective Rendered View NTS 11

Sheet No - 28 - Details (11) - Structural Glazing Sloped @ Pharmacy

Embed Size (px)

Citation preview

Page 1: Sheet No - 28 - Details (11) - Structural Glazing Sloped @ Pharmacy

150mm Precast Concrete HollowcoreFloor Slab Has A Span Of 10M

Steel Base Plate To SuppportCHS Above

120mm PIR Rigid InsulationBeing Used On Ground Level

75mm Self Leveling Stuctural Screed

4mm Mormoleum Floor Finish

300mm Cast Insitu Concrete Column

Concrete Infill To SupportDrainage Channel

30mm Sand Blinding BeneathPaving

60x100mm PermeablePaving 1:50 Gradient

Drainage Channel Used To DrainWater Away From Curtain Walling

Hardcore

150mm Corble To Allow SteelBAse Plates To be Fixed To InTerm Supporting Structural Glazing

Machined stainless Steel AngleBrackets Supporting StructuralGlazing

50mm PIR Rigid InsulationUSed To Stop Cold Bridging

Steel PLate Used To DrainWater Away From Glazing

25mm Sloped Structural Glazing2400x2400mm Panel Sizes

Aluminium Plate used to Hold TheGlazing In Place

Aluminium Spider Clamp Used ToSupport The Structural Glazing

Suitable Sealant Used To SealPanels And Make An Airtight Seal

219mm Hot Rolled CHS Secondary Structure ToSupport Structural Glazing

100mm CHS Acting As A Truss Rod SupportingSteel Rod Which Supports Spider Clamp

Steel Rod Acting As A Truss RodWhich Supports Spider Clamp

Steel Plate Pivetted To An 8Degree Slope To Suit Glazing

Trench Heating UsedTo Stop CondensationOccuring On Glazing

Intumescent Seal UsedFor Fire Proporties

150

120

754

300

150

52

15050

25

180

219

25mm Sloped Structural Glazing2400x2400mm Panel Sizes

Aluminium Plate used to Hold TheGlazing In Place

Aluminium Spider Clamp Used ToSupport The Structural Glazing

Suitable Sealant Used To SealPanels And Make An Airtight Seal

4mm ACM Panel Used As ACoping For The Parapet

50mm PIR Rigid Insulation UsedTo Stop Cold Bridging

4mm Aluminium CompositeMaterial Panel RainscreenCladding 600x1200mm Panel Size

Horizontal Steel Z Bracket Used ToSupport The Main Cladding Rail

50mm Horizontal RainscreenCladding Railing System

180mm Secondary Vertical ColdRolled Steel Structure @ 600 Centres

12mm Fibre Cement Particle BoardContinuing Aroung Steel Frame

3 Degree Slope On ACM Coping To AllowIt To Drain Back Onto The Green Roof

Hot Rolled Steel Channel Used ToForm Upstand On The Parapet

180x250mm Hot Rolled Steel Beam ToBe Approved By Structural Engineer

Vapour Barrier

150mm Growing Medium

40mm Drainage Layer/Pots

120mm PIR Rigid Insulation

180X250mm Hot Rolled Steel Purlin ToBe Approved By Structural Engineer

75mm Self Leveling Stuctural Screed

Machined stainless SteelAngle Brackets SupportingStructural Glazing

Hot Rolled Steel Channel Used ToForm Wall Upstand

Removable ACM Panel In Case GlazingNeeds To Be Repaired Or Cleaned

Intumescent Seal Used For FireProporties

Vapour Barrier

219mm Hot Rolled CHS Secondary Structure ToSupport Structural Glazing

100mm CHS Acting As A Truss Rod SupportingSteel Rod Which Supports Spider Clamp

Steel Rod Acting As A Truss RodWhich Supports Spider Clamp

3 Degree Slope On ACM Coping To AllowIt To Drain Back Onto The Green Roof

Protection mat to prevent mechanicaldamage to the waterproofing system

PE Foil Seperator Layer Between TheWaterproofing & Green Roof Components

Gravel Or Stone

203

250

7512

040

150

3Sheet No - 28

Sim

2Sheet No - 29

Sim

1Sheet No - 28

Sim

1Sheet No - 32

Sim

Scale

LECTURER

Drawn by

Date

Project number

As indicated

22/0

4/20

16 2

0:53

:10

Details (11) - Structural GlazingSloped @ Pharmacy

3

15/03/16

Con Mc Evoy

Noel Dunne, Dan O'Sullivan &Mark Duffy

Sheet No - 28

1 : 5Structural Glazing Foundation1

1 : 5Structural Glazing W/ Green Roof3

1 : 20120 ACM Panel Section5

Key PlanNTS

6

3D Perspective Rendered ViewNTS

7

4150

3600

3920

3000

1100mm High GlassBalustrade Provided ForHealth And Safety Reasons

Green Roof

TintedInternalGlass

Intermediate Floor

Circular HollowSections

Ground Floor Level

ACM Rainscreen Cladding

3000x3000mm StructuralGlazing Panels

Basement RaftFoundation

300mm WallBuild Up InBasement

InternalPartitionWall

Section Cut Structural GlazingNTS

4

The Steel Plates And Angled Brackets Protecting And SupportingThe Structural Glazing Are Removable So That In The Event WhereA Panel Is Broken And Needs To Be Replaced It Is Easy To Do So.

This Also Applies To The Top As The Angle Brackets And CladdingPanels Are Removable As To Get Easy Access To Replace TheStrucural Glazing.

Removable BracketsNTS

8Removable Cladding Panel

NTS10

Removable Aluminium BaseCover Panels

NTS9

3D Perspective Rendered ViewNTS

11