3
High Performance Dual Stage Power Line Filter RP240 SINGLE PHASE TO 150A CHASSIS MOUNT FILTER ROHS COMPLIANT RADIUS POWER Your Power Partner RP RP240 Series 30 www.radiuspower.com Engineering Assistance: [email protected] Sales:[email protected] Operating Freq. : 50/60Hz Usable Freq. : DC - 400Hz Max. Operating Voltage : 250V +10% Ambient Temperature : -25 to 50C Climatic Category : 25/100/21 Hipot Rating (L-G) : 2700VDC Terminals (-T) : QD: 0.25 Tabs (6-16A) S: 25-50A (M5) 80A (M6) 100/150A (M10) Safety Approvals : cURus, EN60939 SPECIFICATIONS Note: Use any combination of -Y with any -X (Amps) rating e.g. RP240-50-4.7-S (50Amps with 4.7nF Ycap) SCHEMATIC Y-cap, nF mA, 120V/60Hz mA, 250V/60Hz 0 0 0 2.2 0.2 0.4 4.7 0.4 0.8 10 0.9 0.18 22 2 4 100 9 1.8 LEAKAGE CURRENT RP240 -X (Amps) -Y (Ycap, nF) -T Weight LBS (KG) Typ. 6 0 QD 0.8 (0.4) 12 2.2 2.6 (1.2) 16 4.7 2.6 (1.2) 25 10 S 3.2 (1.5) 36 22 4.0 (1.8) 50 100 4.0 (1.8) 80 6.0 (2.7) 100 7.0 (3.2) 150 8.0 (3.6) PART NUMBER/ ORDERING Reference purposes only. Specifications are subject to change. Consult factory to verify specifications.

Single Phase EMI Filter - RP240 Series

Embed Size (px)

DESCRIPTION

High Performance Dual Stage Power Line Filter

Citation preview

Page 1: Single Phase EMI Filter - RP240 Series

High Performance Dual Stage Power Line Filter

RP240SINGLE PHASE TO 150ACHASSIS MOUNT FILTER

ROHS COMPLIANT

RADIUS POWERYour Power PartnerRP

RP240 Series

30

www.radiuspower.com

Engineering Assistance: [email protected]:[email protected]

Operating Freq. : 50/60HzUsable Freq. : DC - 400HzMax. Operating Voltage : 250V +10%Ambient Temperature : -25 to 50CClimatic Category : 25/100/21Hipot Rating (L-G) : 2700VDC Terminals (-T) : QD: 0.25 Tabs (6-16A)

S: 25-50A (M5) 80A (M6) 100/150A (M10)

Safety Approvals : cURus, EN60939

SPECIFICATIONS

Note: Use any combination of -Y with any -X (Amps) rating e.g. RP240-50-4.7-S (50Amps with 4.7nF Ycap)

SCHEMATIC

Y-cap, nF mA,120V/60Hz

mA,250V/60Hz

0 0 02.2 0.2 0.44.7 0.4 0.810 0.9 0.1822 2 4

100 9 1.8

LEAKAGE CURRENT

RP240 -X(Amps)

-Y(Ycap, nF) -T

Weight LBS (KG)

Typ.6 0

QD0.8 (0.4)

12 2.2 2.6 (1.2)16 4.7 2.6 (1.2)25 10

S

3.2 (1.5)36 22 4.0 (1.8)50 100 4.0 (1.8)80 6.0 (2.7)100 7.0 (3.2)150 8.0 (3.6)

PART NUMBER/ ORDERING

Reference purposes only.Specifications are subject to change. Consult factory to verify specifications.

Page 2: Single Phase EMI Filter - RP240 Series

RADIUS POWERYour Power PartnerRP

31

www.radiuspower.com

Engineering Assistance: [email protected]:[email protected]

RADIUS POWERYour Power PartnerRP

32

www.radiuspower.com

Engineering Assistance: [email protected]:[email protected]

Mechanical DimensionsRP240 Typical Insertion Loss, dB (50/50ohm) Mechanical Dimensions

RP240 Typical Insertion Loss, dB (50/50ohm)

6 Amp

12/16 Amp

TYPICAL TOLERANCE: +/-0.02 (0.50)

25/36/50 Amp6 AmpFREQ (MHz) .15 .5 1.0 10 30

CM(dB) 60 62 62 52 45DM(dB) 40 60 68 60 60

12/16 AmpFREQ (MHz) .15 .5 1.0 10 30

CM(dB) 60 62 62 50 40DM(dB) 40 60 68 60 60

25/36 AmpFREQ (MHz) .15 .5 1.0 10 30

CM(dB) 24 46 50 60 60DM(dB) 25 40 60 65 65

50 AmpFREQ (MHz) .15 .5 1.0 10 30

CM(dB) 42 50 55 65 60DM(dB) 60 60 65 65 65

TYPICAL TOLERANCE: +/-0.02 (0.50)

Reference purposes only.Specifications are subject to change. Consult factory to verify specifications.

Reference purposes only.Specifications are subject to change. Consult factory to verify specifications.

Page 3: Single Phase EMI Filter - RP240 Series

RADIUS POWERYour Power PartnerRP

33

www.radiuspower.com

Engineering Assistance: [email protected]:[email protected]

Mechanical DimensionsRP240 Typical Insertion Loss, dB (50/50ohm)

80/100 Amp

150 Amp

TYPICAL TOLERANCE: +/-0.02 (0.50)

80 AmpFREQ (MHz) .15 .5 1.0 10 30

CM(dB) 28 44 55 60 60DM(dB) 50 52 65 65 65

100/150 AmpFREQ (MHz) .15 .5 1.0 10 30

CM(dB) 28 44 55 60 60DM(dB) 50 52 65 65 65

Reference purposes only.Specifications are subject to change. Consult factory to verify specifications.