8
SLAYTON 60, SLAYTON 42S & SLAYTON 36 DIRECT VENT LINEAR GAS FIREPLACES QUALITY FIREPLACES FOR LIFE. Slayton 60 shown with Rectangle screen front, Black Crystal glass media and optional Traditional Log Set

SLAYTON 60, SLAYTON 42S & SLAYTON 36...TV Recess Construction 48-3/4” 48-3/4” 19” 19” 62-1/4” 19” (483mm)* is the minimum wall depth required for wall surface material

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • SLAYTON 60, SLAYTON 42S & SLAYTON 36DIRECT VENT LINEAR GAS FIREPLACES

    QUALITY F IREPLACES FOR L IFE.

    Slayton 60 shown with Rectangle screen front, Black Crystal glass media and optional Traditional Log Set

  • 2

    SLAYTON SERIESScreen FrontsSizes shown below: Slayton 60 / Slayton 42S / Slayton 36

    19-13/16” / 21-3/8” /19-13/16”

    19-13/16” / 21-3/8” /19-13/16”

    Rectangle screen front and Amber Crystal glass

    63-1/4” / 47-1/4” / 40-15/16”

    Rectangle screen front with Brushed Nickel, Glacier Crystal glass and optional Driftwood Log Set

    63-1/4” / 47-1/4” / 40-15/16”

    19-13/16” / 21-3/8” /19-13/16”

    Rectangle screen front with Antique Copper, Glacier Crystal glass and optional Traditional Log Set

    63-1/4” / 47-1/4” / 40-15/16”

    Beveled screen front with Amber Crystal glass

    24-11/16” / 26-1/4” / 24-3/8”

    68-1/16” / 52-1/8” / 45-3/4”

    Slayton 60 shown with Beveled screen front and Rock with Reflective Copper crushed glass

  • 3

    Slayton 42S shown with Rectangular screen front with Brushed Nickel Overlay and Driftwood with Glacier Crystal glass

  • 4

    Media & Refractory Options

    Traditional Log Set Driftwood Log Set

    Driftwood/RockRock

    SLAYTON SERIESOptional Accent Media

    Slayton 36 shown with Rectangle screen front and Amber Crystal glass

    Glass Media

    Crushed Glass

    Crystals

    Reflective Midnight

    Glacier

    Black

    Reflective Copper

    Amber

    Seabreeze

  • 5

    SLAYTON SERIESSpecifications

    Remote control features:

    Thermostat function

    Flame height modulation

    Fan speed modulation

    Light kit modulation

    IPI to continuous pilot

    Split Flow Option (Slayton 60 & 42S only)

    The Komfort Kontrol remote gives you the ability to bring comfort and green technology all together into your home. With the Komfort Kontrol remote, all you have to do is decide a comfortable set point temperature on your remote and when the room temperature gets closer to the point you desire, the Komfort Kontrol remote will turn the flames down accordingly! And with our zone heating, you can save energy and enjoy time in the room you use the most by just turning down the central heat, setting your Komfort Kontrol remote, and enjoy your time around the fireplace with friends, family, or just a good book! That way you’ll get to have heat where and when you need it while saving energy and money with just a click of the Komfort Kontrol remote!

    Remote Control

    Outdoor Covered Fireplace Install

    The overhang (A) must be a minimum of 1/2 or greater of the roofline elevation (B) above the base of the fireplace.

    The width of the overhang to each side of the appliance (C) must be a minimum of 1/2 or greater of the roofline elevation (B) above the base of the fireplace.

    EXAMPLE: If roofline (B) is 10 ft. above the base of the fireplace, the overhang (A) must be 5 ft. or greater. The width of the overhang to EACH side of the fireplace (C) must be 5 ft. or greater.

    • Fireplace operation is approved from 40 degrees F to 110 degrees F • All wiring connections shall be in accordance with outdoor requirements of NECA NFPA 70 • All clearances and requirements in your appliance manual must be adhered to

    AB

    CCSIDE OF

    FIREPLACE

    BACK OF FIREPLACE

    FRONT OF FIREPLACE

    ROOF OVERHANG

    AB

    CCSIDE OF

    FIREPLACE

    BACK OF FIREPLACE

    FRONT OF FIREPLACE

    ROOF OVERHANG

    Burn Videos

    Slayton 60 Slayton 42S Slayton 36

  • 39¼”(997mm)

    PREFERREDGAS LINEHOLE

    6

    SLAYTON 36Specifications, Clearances, and Vent System Requirements

    Model Slayton 36

    Height 28-13/16”

    Width 43-5/8”

    Back Width 43-5/8”

    Depth 15-13/16”

    Weight 200 lbs.

    Viewing Area 14-1/16” x 36”

    NG High / Low 33,000 / 17,000

    LP High / Low 33,000 / 17,000

    ENERGUIDE P.4 NG / LP 66.05% / 68.05%

    Steady State NG / LP 71.21% / 73.05%

    AFUE % NG / LP 65.74% / 66.84%

    Valve System IPI

    Split Flow Burner N/A

    Standard Refractory Enamel (curved)

    Glass Media Required

    Accent Media Optional

    Fan Kit Optional

    Finishing Trim Kit Standard

    Screen Front Required

    Model Slayton 36

    From Appliance Corners 4”

    From unit left & right side stand-offs & back 0”

    Top of finishing edge to ceiling 36”

    Side of finishing edge to adjacent sidewall 6”

    Unit front to combustibles 36”

    Mantel projection from fireplace finishing edge*14-1/4”

    *1” deep projection

    Clearances

    Features, Options & Specifications are subject to change.

    Refer to the installation manuals for complete installation & venting requirements.See additional mantel clearance configurations in the installation manual.

    Each unit factory testedCertified to ANSI Z21.88 Vented Gas Heaters

    Slayton 36

    62”43-7/8”

    4”48-3/4”87-3/4”

    24-1/4”

    CORNER

    7-3/4”

    PREFERREDGAS LINEHOLE

    ELECTRICALACCESS

    ALTERNATEGAS LINE HOLE

    28-13/16”

    43-5/8”48-3/4”

    18”

    7-7/8” 5-13/16”4-3/16”

    4-3/4”

    36-5/8”

    5-1/8”

    6-1/8”

    LEFT SIDE FRONT RIGHT SIDE

    36”

    14-1/16”

    19”

    3/8”

    9-15/16”15-13/16”

    48-3/4”

    TOP

    Vent System & Requirements

    This fireplace is manufactured to accept 5”x 8” rigid and flexible pipe.• Simpson Dura-Vent™ DV-PRO pipe - 5”x 8”• Selkirk Metalbestos™ direct chimney system - 5”x 8”• Ameri-Vent/American Metal™ direct chimney system - 5”x 8”• Olympia Chimney Supply• Metal Fab™ 5”x 8”• ICC™ 5”x 8”• Kozy Heat™ flexible #800 series vent kits* - 5”x 8”• BDM™ direct vent chimney system - 5”x 8”

    IMPORTANT: The horizontal heat shield included with this fireplace must be installed when incorporating minimum horizontal venting.

    Elbows: For each additional 90º elbow used after the first elbow, 3’ must be subtracted from the maximum venting allowed. For each additional 45º elbow used after the first elbow, 1½’ must be subtracted from the maximum venting allowed.

    Note: (2) 45º elbows = (1) 90º elbow.Maximum number of elbows for ALL vent configurations = 5

    Horizontal Terminations: Venting configurations vary between NG & LP Gas, please consult the installation manual for requirements.

    Vertical Terminations: Minimum: 2’ Maximum: 50’

    Horizontal/Vertical Combo: Venting configurations vary between NG & LP Gas, please consult the installation manual for requirements.

    62-1/4”

    FRAMING STUDS MUST MAINTAIN 1” CLEARANCE TO VENTING

    36-5/8”

    36-5/8”

    4-1/4”

    TV Recess Construction

    48-3/4”

    48-3/4”

    19”19”

    62-1/4”

    19” (483mm)* is the minimum wall depth required for wall surface material to cover fireplace front. If fireplace face is to be flush with the wall surface, subtract 1/2” (13mm) (typical non-combustible finish material) from this dimension. If other material is to be used, adjust accordingly.

  • FINISHING EDGE

    7

    SLAYTON 42SSpecifications and Clearances(See Vent System Requirements on page 6)

    Model Slayton 42S

    Height 32-9/16”

    Width 50”

    Back Width 50”

    Depth 15-13/16”

    Weight 220 lbs.

    Viewing Area 15-11/16” x 42-3/8”

    NG High / Low 42,000 / 15,000

    LP High / Low 42,000 / 15,000

    ENERGUIDE P.4 NG / LP 72.21% / 75.53%

    Steady State NG / LP 72.98% / 75.45%

    AFUE % NG / LP 68.05% / 70.39%

    Valve System IPI

    Split Flow Burner Standard

    Standard Refractory Enamel (curved)

    Glass Media Required

    Accent Media Optional

    Fan Kit Optional

    Finishing Trim Kit Standard

    Screen Front Required

    Model Slayton 42S

    From Appliance Corners 4”

    From unit left & right side stand-offs & back 0”

    Top of finishing edge to ceiling 36”

    Side of finishing edge to adjacent sidewall 6”

    Unit front to combustibles 36”

    Mantel projection from fireplace finishing edge*14-1/4”

    *9” deep projection

    Clearances

    Features, Options & Specifications are subject to change.

    Refer to the installation manuals for complete installation & venting requirements.See additional mantel clearance configurations in the installation manual.

    Each unit factory testedCertified to ANSI Z21.88 Vented Gas Heaters

    65-5/8”46-3/8”

    4”55-1/4”92-13/16”

    26-3/8”

    CORNER

    38-5/16”

    10-1/16”5-1/4”

    LEFT SIDE5-3/4”

    32-9/16”

    50”55-1/4”

    19-7/16”

    10-11/16”

    8-1/8”

    9-11/16”

    5-1/4”

    5-1/2”

    FRONT RIGHT SIDE

    42-3/8”

    15-11/16”

    3/8”

    19”

    55-1/4”

    9-15/16”15-13/16”

    TOP

    Slayton 42S

    GAS LINE HOLE

    GAS LINE HOLE

    62-1/4”

    FRAMING STUDS MUST MAINTAIN 1” CLEARANCE TO VENTING

    38-3/8”

    38-3/8”

    4-1/4”

    TV Recess Construction

    55-1/4”

    55-1/4”

    19” 19”

    62-1/4”

    19” (483mm)* is the minimum wall depth required for wall surface material to cover fireplace front. If fireplace face is to be flush with the wall surface, subtract 1/2” (13mm) (typical non-combustible finish material) from this dimension. If other material is to be used, adjust accordingly.

    ELECTRICALACCESS

  • In order to continually provide the highest quality product available, features/options, specifications & dimensions are subject to change. Refer to the unit installation manual for complete installation instructions. Installation must conform with local building codes. In some regions it may be possible that this appliance qualifies for an energy rebate. See your local dealer for details regarding promotions and qualifications.

    Manufactured by Hussong Mfg. Co., Inc.204 Industrial Park Road, Lakefield, MN 56150Phone 1-800-253-4904 www.kozyheat.com

    For complete information on the Kozy Heat product line, please contact us at:

    Product Line:

    FOR CALIFORNIA RESIDENTS ONLY California Proposition 65 WarningWARNING: This product can expose you to chemicals including Carbon Monoxide, that is an externally vented by-product of fuel combustion, which is [are] known to the State of California to cause birth defects or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.10-20

    Fireplace brochures are for advertising purposes only. Refer to the specific fireplace manual for installation.

    SLAYTON 60Specifications, Clearances(See Vent System Requirements on page 6)

    Model Slayton 60

    Height 31-1/16”

    Width 66”

    Back Width 66”

    Depth 15-13/16”

    Weight 300 lbs.

    Viewing Area 14-1/4” x 58-3/8”

    NG High / Low 55,000 / 17,500

    LP High / Low 55,000 / 17,500

    ENERGUIDE P.4 NG / LP 73.31% / 75.28%

    Steady State NG / LP 68.6% / 70.5%

    AFUE % NG / LP 66.44% / 68.27%

    Valve System IPI

    Split Flow Burner Standard

    Standard Refractory Enamel (curved)

    Glass Media Required

    Accent Media Optional

    Fan Kit Optional

    Finishing Trim Kit Standard

    Screen Front Required

    Model Slayton 60

    From Appliance Corners 4”

    From unit left & right side stand-offs & back

    0”

    Top of finishing edge to ceiling 36”

    Side of finishing edge to adjacent sidewall 6”

    Unit front to combustibles 36”

    Mantel projection from fireplace finishing edge*

    14-1/4”*9” deep projection

    Clearances

    Features, Options & Specifications are subject to change.

    Each unit factory testedCertified to ANSI Z21.88 Vented Gas Heaters

    Slayton 60

    Refer to the installation manuals for complete installation & venting requirements.See additional mantel clearance configurations in the installation manual.

    HORIZONTAL VENTTERMINATION FRAMING

    62-1/4”

    FRAMING STUDS MUST MAINTAIN 1” CLEARANCE TO VENTING

    36-7/8”

    36-7/8”

    4-1/4”

    TV Recess Construction

    71-1/8”

    71-1/8”

    19” 19”

    62-1/4”

    71-1/16”

    3/8”

    19”

    71-1/16”

    9-15/16”15-13/16”

    TOP

    77-7/8”

    55-1/16”

    4”71-1/8”

    110-1/8”

    32-1/8”

    CORNER

    GAS LINEHOLE

    ELECTRICALACCESS

    GAS LINEHOLEGAS LINE

    HOLE

    ELECTRICALACCESS

    GAS LINEHOLE

    5-3/4”

    31-1/16”

    66”

    17-15/16”

    10-11/16”

    58-3/8”

    8-1/8”

    9-11/16”5-1/4”

    5-1/2”

    GAS LINEHOLE

    ELECTRICALACCESS

    GAS LINEHOLE36-7/8”

    10-1/16”5-1/4”

    LEFT SIDE FRONT RIGHT SIDE

    14-1/4”

    19” (483mm)* is the minimum wall depth required for wall surface material to cover fireplace front. If fireplace face is to be flush with the wall surface, subtract 1/2” (13mm) (typical non-combustible finish material) from this dimension. If other material is to be used, adjust accordingly.