2

Click here to load reader

Smart – Quick Start Manual BeltColor & GraviColor · Smart – Quick Start Manual BeltColor & GraviColor Additive Dosing for Extrusion machines 1 – Start System ... Press Reset

  • Upload
    letram

  • View
    215

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Smart – Quick Start Manual BeltColor & GraviColor · Smart – Quick Start Manual BeltColor & GraviColor Additive Dosing for Extrusion machines 1 – Start System ... Press Reset

Smart – Quick Start Manual

BeltColor & GraviColor Additive Dosing for Extrusion machines

1 – Start System

OUTPUT – setting the required output

ALARMS – system’s alarms SERVICE – service and maintenance

2 – Set the Required Output

SET – set the required output ACT – actual output SPEED – feeder’s motor speed STOCK – material stock estimation TOTAL – total weight of additive Press Reset to reset the counters Press Back to return to Main Menu

3 – Control System Alarms

F1

F2

F3

F4

F5

F6<Alarm Cancel Back>

NO ALARMS

Last>

Press Alarm Cancel to cancel an active alarm Press Last to see the last alarm Press Back to return to Main Menu

For further assistance please refer to the

User Manual or contact Sysmetric

Sysmetric Ltd P.O.B. 1122, Afula Illit 18550, Israel

Phone: +972-4-6405857 Fax: +972-4-6405911 [email protected] www.sysmetric-ltd.com

s i m p l y a c c u r a t e

Page 2: Smart – Quick Start Manual BeltColor & GraviColor · Smart – Quick Start Manual BeltColor & GraviColor Additive Dosing for Extrusion machines 1 – Start System ... Press Reset

DRAIN OFF ON

CONVEYER0 1

Electrical Wiring

FUSE

FUSE

1

0

PA PB PC

0.5A

5A

MAIN

PB PCPA GROUND

NEUTRAL

PHASE

COMMON 0VDCCOMMON 24VDCEXTRUDER ON

NOT USED INPUT

ANALOG 0V

ANALOG 0-10V

SHIELD

ALARM)DRY CONTACT(

1 1 1

2 2 2

BLACK

RED

WHITE

BROWN

GREEN

BLUE

BLACK

RED

SHIELD

GREEN

GREEN

YELLOW/GREEN

TOMOTOR

TO WEIGHING

UNIT

MAIN

SWITCH

ETHERNET

PLUGAMPILFIER FUSE 5 X 20 0.5A

MAIN FUSE 6.3 X32 5A

RESERVED

RESERVED

1. Connect power supply – Ground, Neutral, Phase 2. Connect control signal from extruder – Extruder On 3. Connect alarm dry contact (optional)

Feeder Operation Activating the GraviColor 1. Turn the conveyer switch to 1 – the unit will load material 2. Hold the system switch at TEACH for 3 seconds – the unit will perform a teach cycle 3. Set the required output 4. Turn the system switch to ON – material will start flowing according to Extruder On signal Activating the BeltColor 1. Turn the conveyer switch to 1 – the unit will load material 2. Turn the system switch to ON – the unit will perform a teach cycle 3. Set the required output 4. Material will start flowing according to Extruder On signal

System Lamps

Switch Lamp State

System (green)

off system is off on system is on flashing steadily extruder on flashing alternately teach cycle flashing rapidly system alarm

Conveyer (orange)

off conveyer is off on conveyer is on flashing rapidly conveyer alarm

s i m p l y a c c u r a t e

TEACH OFF ON

CONVEYER0 1