26
SOLAR BATTERIES Exide Industries Limited, India

Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

SOLAR BATTERIES

Exide Industries Limited, India

Page 2: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

Headquartered in Kolkata, India

Products : Lead Acid Storage Batteries : 2.5Ah to 20,000 Ah Home UPS DC Power Solution Standby Products & Solutions

9 Manufacturing units in India

1 R&D Center in India

5 Wholly owned Subsidiaries in India

Turnover of USD 1.3 Billion

An Integrated Manufacturing Unit for Standby Systems and DC Power solutions in Kolkata, India.

Page 3: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

Over the last decades, the focus in renewable energy usage to meet the growing power demand has increased manifold. It is considered to be the EFFICIENT SOLUTION to vast stretches of remote stretches of remote areas where man’s power is yet to reach in an economic manner.

The success of the SPV SYSTEM largely depends on efficiency of its storage. Storage of solar power is a challenge as the electricity produced form SOLAR PANELS are intermittent and specially designed battery is required to effectively store this electricity and provide power optimally whenever required. The battery thus used is to be Suitable to withstand daily charge - discharge cycle to work efficiently in partial state of charge (PSOC) condition and to be able to get recharged at a fast pace even at low/avoidable current.

KEY FEATURES:

• The only company in India to manufacture batteries from 2.5Ah to 20,400Ah collaborations with SHIN KOBE AND FURUKUWA OF JAPAN.

• Subsidiaries in SINGAPORE, UK and SRI LANKA.

• Fast growing exports, currently to 30 countries in 5 continents

• R & D CENTRE, set up in 1976, is counted among the premium battery research facilities in the world and is approved by the DEPT. OF SCIENCE AND TECHNOLOGY, Govt. Of India as independent test laboratory.

• Certified with ISO 9001 and ISO 14001.

Page 4: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity
Page 5: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

CONTENT

Model Technology Nominal Voltage Range

LMS

OPzS

OPzS

NXT

NMST

SGL

SG

OPzV

FLOODED TUBULAR

FLOODED TUBULAR

FLOODED TUBULAR

AGM VRLA

AGM VRLA

TUBULAR GEL

TUBULAR GEL

TUBULAR GEL

12V

2V

6V

12V

2V

12V

2V

2V

20Ah - 200 Ah

100Ah - 3000Ah

250Ah - 300Ah

LMXT FLOODED TUBULAR 2V 300Ah - 1000Ah

17Ah - 200Ah

160Ah - 5000Ah

40Ah - 200Ah

200Ah - 1000Ah

200Ah - 3000Ah

Page 6: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

12VLMSDEEP CYCLE FLOODED TUBULAR

Page 7: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

12VLMS

7

TUBULAR POSITIVE PLATES

PASTED NEGATIVE PLATES

ACID RESISTANT POLYSTER GAUNTLETS

HIGH POROSITY ENVELOPE SEPARATORS

AVAILABLE IN SOLA-TUBULAR RANGE

MICROPOROUS CERAMIC VENT PLUG

FEATURES

*HEIGHT UPTO TERMINAL TOP

TECHNICAL SPECIFICATIONS

0

1000

2000

3000

4000

5000

6000

10 20 30 40 50 60 70 80 90

Num

ber o

f Cyc

les

Depth Of Discharge %

Cycle Life vs. DOD for 12V LMS

Page 8: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

2V

2V OPzSFLOODED TUBULAR

MICROPOROUS VENT PLUGS

MICROPOROUS AND RESIN BASED SEPARATORS

LARGE ELECTROLYTE VOLUME

LOW ANTIMONY ALLOY IN POSITIVE PLATE

FEATURES

Page 9: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

2VOPzS

9

TECHNICAL SPECIFICATIONS

Type

C100 Capacityupto 1.85

V/Cell

C72Capacityupto 1.85

V/Cell

C20Capacityupto 1.80

V/Cell

C10Capacityupto 1.80

V/Cell

Weight +/- 5% (Kg) Overall Cell Dimensions

4OPzS 200

5OPzS 250*

OPzS 250

6OPzS 300*

5OPzS 350*

OPzS 350

6OPzS 420

OPzS 500

6OPzS 600

7OPzS 700*

OPzS 700

8OPzS 800*

OPzS 800

9OPzS 900

10 OPzS 1000

11OPzS 1100

OPzS 1125

12OPzS 1200*

OPzS 1250

12OPzS 1500

13OPzS 1625*

14OPzS 1750*

16OPzS 2000*

18OPzS 2250*

20OPzS 2500*

22OPzS 2750*

24OPzS 3000*

3610

3980

4340

3250

3575

3900

OPzS 300

280

350

350

420

520

520

620

730

910

1070

1070

1220

1220

1370

1520

1630

1670

1740

1820

2170

2355

2540

2900

3250

420

260

325

325

390

455

455

546

650

780

910

910

1040

1040

1170

1300

1430

1462

1560

1625

1950

2112

2275

2600

2925

390

240

300

300

360

420

420

504

600

720

840

840

960

960

1080

1200

1320

1350

1440

1500

1800

1950

2100

2400

2700

3000

3300

3600

2500

2750

3000

360

200

250

250

300

350

350

420

500

600

700

700

800

800

900

1000

1100

1125

1200

1250

1500

1625

1750

2000

2250

300

Dry

14.4

16.0

19.8

19.1

22.0

24.5

25.8

31.0

35.4

42.6

45.6

47.0

49.1

53.4

57.4

62.5

65.5

67.0

70.1

84.0

96.0

102.0

110.7

131.5

145.0

158.5

170.0

22.5

Acid Filled

34.7

19.2

22.0

31.0

26.5

30.3

35.9

45.9

49.4

61.5

70.9

65.4

73.5

77.1

80.2

89.3

104.5

93.2

106.2

117.9

148.3

153.4

160.0

193.4

204.8

231.8

241.5

33.2

Approx Qtyof acid1.220spgr (litres)

3.9

4.9

9.2

8.8

6.4

8.3

12.2

11.5

15.5

15.1

20.7

15.1

20.0

19.4

18.7

22.0

32.0

21.5

29.6

40.4

42.1

42.9

27.8

50.7

49.0

60.1

58.4

6.1

Length+/- 3mm

103

124

124

145

145

145

145

210

210

210

210

210

210

210

210

210

210

210

214

214

214

212

212

212

212

145

145

145

Width+/- 3mm

206

206

206

206

206

206

206

206

206

191

233

191

233

233

233

275

275

275

275

275

399

399

399

487

487

576

576

206

Height+/- 3mm

430

430

546

430

546

546

546

721

721

721

721

721

721

721

721

721

721

871

871

871

847

847

847

847

847

847

847

546

* Imported Cell Box where lead time is 12 - 14 weeks. The same cells can be supplied in higher indigenous cell box which can be despatched in 4 - 5weeks The dimension of indegenous cell box is mentioned in above table.

CYCLE LIFE

100

80

6080%DOD

40%DOD

20%DOD

40

20

1000 2000 3000 4000 5000 6000 7000 8000

Dep

th o

f Disc

harg

e (%

)

Number of cycles

Page 10: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

6V

6V OPzSFLOODED TUBULAR

Page 11: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

6VOPzS

11

LOW ANTIMONY ALLOY IN POSITIVE PLATE

INSULATED INTERCELL COPPER CONNECTORS

LARGE ELECTROLYTE VOLUME

MICROPOROUS VENT PLUGS

PLASTIC ENCAPSULATED BOLTS ON TERMINALS

TRANSPARENT SAN CONTAINER

TUBULAR PLATES

MICROPOROUS AND RESIN BASED SEPARATORS

FEATURES

Type

3OPzS250

3OPzS300 6V

6V

300

250

1.240

1.240 487 187 388 440 40.0 64.5

44.5 68.5440388187487

NominalVoltage

(V)

Capacity10Hrsrate @270C

to1.80vpc

OverallHeight

(+/-5mm)

Weight (+/-3%)OpetatingEectrolyteSpecific

Gravity at270C

(+/-0.005)

Dimension (+/- 3mm)

Length(mm)

Dry(Kg)

Filled(Kg)

Width(mm)

Height(mm)

TECHNICAL SPECIFICATIONS

Page 12: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

2V

LMXTFLOODED TUBULAR

Page 13: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

2VLMXT

13

TUBULAR POSITIVE PLATES MADE IN HIGH PRESSURE HADI CASTINGMACHINE

BATTERIES UPTO 800Ah ARE FITTED WITH MH MODULES (8/6/4V)

SPECIALLY NON WOVEN GAUNTLET FOR POSITIVE PLATES

IDEALLY SUITED FOR PSOC CONDITION

BATTERIES ARE SUPPLIED IN FACTORY CHARGED CONDITION

EXCELLENT CYCLE LIFE

FEATURES

TECHNICAL SPECIFICATIONS

8000

7500

7000

6500

6000

5500

5000

4500

4000

3500

3000

2500

2000

1500

1000

500

020 30 40 50 60 70 80 90

No

of C

ycle

s

Depth of discharge

Page 14: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

12VNXTDEEP CYCLE AGM VRLA

FAST RECHARGE CAPABILITIES

DEEP CYCLE APPLICATION

EXTENDED CYCLE LIFE

FREE FROM ORIENTATIONCONSTRAINTS

ECO - FRIENDLY

EXCELLENT CHARGE RETENTION

FAST RECOVERY FROM DEEP DISCHARGE

FEATURES

Page 15: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

12VNXT

15

TECHNICAL SPECIFICATIONS

BatteryType

NominalVoltage

(V) 20 hr1.75

V/cell

10h r1.75

V/cell

5 hr1.75

V/cell

3 hr1.75

V/cell

2 hr1.75

V/cell

90 min1.75

V/cell

60 min1.75

V/cell

30 min1.75

V/cell

OverallHeight

± 3

Heightupto

lid ± 3

Weight(Kg)

± 5%

InternalResista-

nce(m-ohm)

MaxDischarge

Current(Amps)

Length± 2

Width± 2

Rated Capacity (Ah) at 270C Dimensions (mm)

NXT 17-12

NXT 26-12

NXT42-12

NXT65-12

NXT100-12

NXT150-12

NXT200-12

12

12

12

12

12

12

12

17

26

42

65

100

150

200

15.5

23.5

38.0

58.5

90.0

135.0

180.0

14.0

21.0

34.0

52.5

81.0

121.5

162.0

13.0

19.5

31.5

49.0

75.0

112.5

150.0

12.0

18.0

29.5

45.5

75.0

112.5

140.0

11.0

17.0

27.5

43.0

66.0

99.0

132.0

9.5

14.5

23.0

36.0

55.0

82.5

110.0

7.5

11.5

19.0

29.5

45.0

67.5

90.0

167

175

190

174

235

240

240

167

175

190

174

235

240

240

181

166

197

350

407

557

533

76

125

165

166

173

172

250

5.9

9.6

13.8

22.0

32.8

45.8

63.6

15

10

8

8

6

6

5

255

390

420

500

600

900

1200

Note: Batteries are dispatched from factory at minimum 90% state of charge. Full capacity is achieved after a minimum ten numbers of charge – discharge cycle at full depth or 3 months of continuous �oat operation.

NXT SERVICE LIFE

120

100

80

60

40

20

00 300 600 900 1200 1500 1800 2100 2400 2700 3000

DOD 80% DOD 50% DOD 30%

(1) Final Voltage : 1.75V/Cell(2) Charge Current : 0.2CA(3) Ambient Temperature : 25 C

Capa

city

(%)

Number of cycles

Cycle Service Life

Page 16: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

2V

2V AGM VRLAMAINTENANCE FREE

HASSLE FREE HANDLINGvAND EASY INSTALLATION

LOW SELF DISCHARGE NO WATER TOPPINGUP REQUIRED

FACTORY CHARGED

FEATURES

Page 17: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

2VVRLA

17

BatteryType

Capacity @10hr/1.75V

(Ah)

Module Dimensions (mm)ModuleNominalVoltage

Weight (Kg) 5%

L5

D5

H5

NEPST

NEPST

NEPST

NEPST

NEPST

703

703

703

682

733

423

423

423

424

415

268

268

268

292

236

12

12

12

12

8

87

96

108

114

118

200

240

280

300

400

NMST

NMST

NMST

NMST

NMST

NMST

NMST

NMST

NMST

NMST

NMST

NMST

500

600

800

1000

1250

1500

2000

2500

3000

4000

5000

6000

8

8

4

4

4

4

2

2

2

2

2

2

789

789

462

462

436

436

436

436

436

872

872

872

540

540

540

540

540

540

540

540

540

540

540

540

255

255

363

363

511

511

363

511

511

363

511

511

148

166

122

145

179

200

145

179

200

290

358

400

TECHNICAL SPECIFICATIONS

100

80

6080%DOD

50%DOD

20%DOD

40

20

1000 1500 2000 4000 5000

Dep

th o

f Disc

harg

e (%

)

Number of cycles

Page 18: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

12V12V TUBULAR GEL VRLADEEP CYCLE GEL TECHNOLOGY

Page 19: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

12VMonoblock

19

FEATURES

SUPPLIED FACTORY CHARGED.

GREATER DESIGN LIFE - BEST VALUE FOR MONEY.

LONG SHELF LIFE.

LESS SENSITIVE TO

SUPERIOR CYCLE LIFE.

SEALED MAINTENANCE FREE - NO TOPPING UP EVER.

EXCELLENT DEEP DISCHARGE.

HIGH RECHARGE EFFICIENCY.

TECHNICAL SPECIFICATIONS

CAPABILITIES TEMPERATURE.

0

1000

2000

3000

4000

5000

6000

7000

10 20 30 40 50 60 70 80 90

Cycl

e Li

fe

%Depth Of Discharge

Cycle Life vs. DOD for 12V Gel

Page 20: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

2V

2V TUBULAR GEL VRLAStandard :BS

Page 21: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

2VSG

21

POSITIVE PLATE:ROBUST

TUBULAR SPINEWITH Pb-Ca-Sn ALLOY

NEGATIVE PLATE:Pb-Ca ALLOY GRID.

ELECTROLYTE:SULPHURIC ACIDIN IMMOBILIZEDGELLED FORM

SPECIALLY MADE BYMIXING THIXOTROPIC

INERT ADDITIVES.

CONTAINER AND LID:MADE OF HIGH GRADE

ADDITIVE FILLEDPOLYPROPYLENE

CO-POLYMER MATERIAL.

VALVE:FLAME ARRESTING

VENT PLUG HOUSINGLONG LIFE RUBBER

SAFETY VALVE.

BOLT: ON TERMINALWITH BRASS INSERT.

FEATURES

TECHNICAL SPECIFICATIONS

Cycle Life vs. DOD for 2V Gel @ 40 Deg C Cyclic Applica on

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

10 20 30 40 50 60 70 80 90 100

Cycl

e Li

fe

No. Of Cycles

Page 22: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

TECHNICAL SPECIFICATIONS

2VOPzV

22

TypeNominal Voltage

(V)

Nominal Capacity

C10 1.8V/C

20° (Ah)

Discharge Current

I 10

(A)

Length (l)

Max.

mm

Width (b)

Max.

mm

Height (h1)

Max.

mm

Height (h2)

Max.

mm

Weight

Approx.

Kg

5 OPzV 250

6 OPzV 300

5 OPzV 350

6 OPzV 420

7 OPzV 490

6 OPzV 600

8 OPzV 800

10 OPzV 1000

12 OPzV 1200

12 OPzV 1500

16 OPzV 2000

20 OPzV 2500

24 OPzV 3000

2

2

2

2

2

2

2

2

2

2

2

2

2

250

300

350

420

490

600

800

1000

1200

1500

2000

2500

3000

25

30

35

42

49

60

80

100

120

150

200

250

300

126

147

126

147

168

147

212

212

212

212

215

215

215

208

208

208

208

208

208

193

235

277

277

400

490

580

360

360

475

475

475

650

650

650

650

800

775

775

775

398

398

513

513

513

688

688

688

688

838

815

815

815

23

27

30

35

40

48

67

80

94

118

160

200

240

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

10000

10 20 30 40 50 60 70 80 90

Cycl

e Li

fe

% Depth Of Discharge

Cycle Life vs. DOD for OpzV

Page 23: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

2V2V OPzVSTANDARD: DIN

ANTIMONY FREE ALLOY

VALVE REGULATED

FILLED AND CHARGED

ELECTROLYTE IN GEL FORM

VERSATILE IN MOUNTING

READY TO INSTALL

EXCELLENTTHERMAL MANAGEMENT

HIGH PRESSUREDIE-CAST SPIN GRID

TUBULAR POSITIVE PLATES

OPzV FEATURES

Page 24: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity
Page 25: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity
Page 26: Solar Brochure 13917 LR - Industrial Batteries · LMS OPzS OPzS NXT NMST SGL SG OPzV FLOODED TUBULAR FLOODED TUBULAR FLOODED TUBULAR AGM VRLA AGM VRLA ... upto 1.85 V/Cell C72 Capacity

Wherever we own the brand

NorwayUKCanadaCroatiaPolandGreeceMaltaIsraelJordanEgyptBahrainQatarPeru ArgentinaMaliNigeriaBotswanaSouth AfricaZambiaTanzaniaMozambiqueKenyaMauritiusUAE

Sri Lanka MalaysiaNew ZealandAustraliaSingaporeIndonesiaBruneiPhilipinesThailandCambodiaVietnamHong KongTaiwanBangladeshChinaJapanKoreaAfghanistanOmanKuwaitArmeniaFinlandGermanyScotland

Glo

bal P

rese

nce

Manufacturing Facilities

India