48
STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesign People get lost. We fix that. TM Prepared by All ideas, designs, arrangements and plans indicated or represented by these drawings are owned by, and property of OHSU and Corbin Design and were created, evolved and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm or corporation for any purpose whatsoever without the written permission of Corbin Design and OHSU.

STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

STANDARDS MANUAL FOR WAYFINDING SIGNAGEAugust, 2018

109 East Front Suite 304Traverse City, MI 49684231 947.1236

corbindesignPeople get lost. We fix that.TM

Prepared by

All ideas, designs, arrangements and plans indicated or represented by these drawings are owned by, and property of OHSU and Corbin Design and were created, evolved and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm or corporation for any purpose whatsoever without the written permission of Corbin Design and OHSU.

Page 2: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

Table of Contents

Kx-1: Pedestrian Map Kiosk . . . . . . . . . . . . . . . . . . . . . . . . . . 68

Kx-2: Pedestrian Map, Small, Wall Mounted . . . . . . . . . . . . . 69

Kx-3: Parking Kiosk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

Nx-1: Notice Plaque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

Px-1,a,b: Garage ID, Freestanding, Large . . . . . . . . . . . . . . . . 72

Px-2: Garage ID, Projecting . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Px-2b,c: Garage ID, Electronic, Projecting . . . . . . . . . . . . . . . . 76

Px-2d: Garage ID, Wall Mounted, Non-Illuminated . . . . . . . . . 77

Px-2e: Garage ID, Projecting, Small, Illuminated . . . . . . . . . . 78

Px-3: Garage ID, Bulkhead Mounted . . . . . . . . . . . . . . . . . . . 79

Px-3a: Garage ID, Wall Mounted, Custom Curve . . . . . . . . . . 80

Px-4: Garage ID, Freestanding, Small . . . . . . . . . . . . . . . . . . . 81

Px-5: Staff Lot ID, Freestanding . . . . . . . . . . . . . . . . . . . . . . . 82

Px-6,a,b,c,d,e,f: Garage Entrance/Exit ID . . . . . . . . . . . . . . . . 83

Px-7: Garage Entrance ID, Wall Mounted . . . . . . . . . . . . . . . . 88

Px-8,a,8 .2: Overhead Guide, Long . . . . . . . . . . . . . . . . . . . . . 89

Px-8b,c,b .2: Overhead Guide . . . . . . . . . . . . . . . . . . . . . . . . . 91

Px-9,a,9 .2: Overhead Guide, Short . . . . . . . . . . . . . . . . . . . . . 92

Px-9b,c,b .2: Overhead Guide . . . . . . . . . . . . . . . . . . . . . . . . . 93

Px-10,a: Overhead Two Way Traffic . . . . . . . . . . . . . . . . . . . . 94

Px-11,a,b: Overhead Clearance . . . . . . . . . . . . . . . . . . . . . . . 95

Px-12,a,b: Overhead, Pedestrian . . . . . . . . . . . . . . . . . . . . . . 97

Px-14,a,b: Elevator Level ID . . . . . . . . . . . . . . . . . . . . . . . . . 100

Px-15,a,b,c,d,e: Garage Level ID . . . . . . . . . . . . . . . . . . . . . 104

Px-16,a: Elevator Directory Level ID . . . . . . . . . . . . . . . . . . . 106

Px-17: Vehicular Guide, Column Mounted . . . . . . . . . . . . . . 108

Px-18: Remember Your Ticket . . . . . . . . . . . . . . . . . . . . . . . 109

Px-20,a: Electronic Sign . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

Rx-1,2,a,3,4,a,b,c: Regulatory Signs . . . . . . . . . . . . . . . . . . . 111

Rx-5: Regulatory Stairwell ID . . . . . . . . . . . . . . . . . . . . . . . . 114

Rx-5a: Regulatory Stairwell ID, Exterior Grade . . . . . . . . . . . 115

Rx-6,a: Regulatory, Campus Boundary . . . . . . . . . . . . . . . . . 116

Rx-6b: Regulatory, Pole Mounted, Tall . . . . . . . . . . . . . . . . . 117

Rx-7: Parking Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118

Vx-1,2,3,4: Vinyl on Glass . . . . . . . . . . . . . . . . . . . . . . . . . . 119

INTERIOR DESIGN INTENT DRAWINGS

Interior Fabrication Specifications . . . . . . . . . . . . . . . . . . . . . 123

SIGN TYPE ARRAYS

Exterior and Parking Sign Type Array . . . . . . . . . . . . . . . . . . . . 3

Interior Sign Type Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

EXTERIOR AND PARKING DESIGN INTENT DRAWINGS

Exterior and Parking Fabrication Specifications . . . . . . . . . . . . 19

Color Palette, Typography & Symbols . . . . . . . . . . . . . . . . . . . 21

OHSU Logos & Partnership Logos . . . . . . . . . . . . . . . . . . . . . 22

Parking Level Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Cx-1: Campus ID, Pole Mounted . . . . . . . . . . . . . . . . . . . . . . 24

Cx-2,a: Campus ID, Monument . . . . . . . . . . . . . . . . . . . . . . . 25

Cx-3,a: Logo/Flame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Cx-4: Custom Entry OHSU Panel . . . . . . . . . . . . . . . . . . . . . . 29

Cx-5: Campus ID & Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Gx-0,a: Extra Large Guide/ID . . . . . . . . . . . . . . . . . . . . . . . . . 32

Gx-1,a,b,c: Vehicular Guide, Large . . . . . . . . . . . . . . . . . . . . . 33

Gx-2,a: Vehicular Guide, Small . . . . . . . . . . . . . . . . . . . . . . . . 36

Gx-3,a: Post & Panel Guide . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Gx-5,a,b,c,d,e: Pedestrian Guide . . . . . . . . . . . . . . . . . . . . . . 38

Ix-1: Building ID, Pole Mounted, HC . . . . . . . . . . . . . . . . . . . . 41

Ix-1a: Building ID, Pole Mounted, RA . . . . . . . . . . . . . . . . . . . 42

Ix-1b,c: Custom Building ID, Pole Mounted, HC . . . . . . . . . . . 43

Ix-2: Building ID, Wall Mounted, HC . . . . . . . . . . . . . . . . . . . 45

Ix-2a: Building ID, Wall Mounted, RA . . . . . . . . . . . . . . . . . . . 46

Ix-4: Entrance ID, Wall Mounted . . . . . . . . . . . . . . . . . . . . . . 47

Ix-5: Emergency ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Ix-6,a,b: Individual Letters, Canopy Mounted . . . . . . . . . . . . . 49

Ix-7: Entrance ID, Projecting, Small, Illuminated . . . . . . . . . . . 55

Ix-7a: Entrance ID, Projecting, Small, Non-Illuminated . . . . . . 56

Ix-8: Entrance ID, Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

Ix-9: Individual Letters, Illuminated . . . . . . . . . . . . . . . . . . . . . 58

Ix-9a: Individual Letters, Non-Illuminated . . . . . . . . . . . . . . . . 59

Ix-10: Offsite Building ID, Vertical . . . . . . . . . . . . . . . . . . . . . . 60

Ix-10a: Offsite Building ID, Horizontal . . . . . . . . . . . . . . . . . . 62

Ix-10c: Offsite Building ID, Custom . . . . . . . . . . . . . . . . . . . . 64

Ix-11: Offsite Building ID, Horizontal . . . . . . . . . . . . . . . . . . . 65

Ix-11a: Offsite Building ID, Vertical . . . . . . . . . . . . . . . . . . . . . 66

Ix-12a,b,c,d: Retrofit Panels . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Color Palette, Typography & Symbols . . . . . . . . . . . . . . . . . . 125

Interior Hanging Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . 127

D-1,a: Main Directory w/ Handheld Map . . . . . . . . . . . . . . . 129

D-2,a,b,c,d,e,f: Main Directory . . . . . . . . . . . . . . . . . . . . . . . 133

D-3: Elevator Directory, Decorative . . . . . . . . . . . . . . . . . . . . 143

D-3a: Elevator Directory, Standard . . . . . . . . . . . . . . . . . . . . 145

D-3b,c,e,f,g: Elevator and Physician Directory . . . . . . . . . . . . 147

D-4,a: Strip Map, Decorative . . . . . . . . . . . . . . . . . . . . . . . . 152

D-4b,c: Strip Map, Standard . . . . . . . . . . . . . . . . . . . . . . . . 153

D-5: Transitional Elements . . . . . . . . . . . . . . . . . . . . . . . . . . 154

G-1,a,b: Guide Sign, Decorative . . . . . . . . . . . . . . . . . . . . . . 155

G-2,a,b: Guide Sign, Standard . . . . . . . . . . . . . . . . . . . . . . . 160

G-3: Guide Sign, Freestanding . . . . . . . . . . . . . . . . . . . . . . . 162

G-4a,b: Guide Sign, Custom . . . . . . . . . . . . . . . . . . . . . . . . 163

I-1,a: Primary ID, Decorative . . . . . . . . . . . . . . . . . . . . . . . . . 164

I-1b,c,d,e: Primary ID, Standard . . . . . . . . . . . . . . . . . . . . . . 167

I-2,a: Secondary ID, Conf . Room ID w/ Insert Holder . . . . . . 176

I-3,a,4,a: General Room/Patient Room ID . . . . . . . . . . . . . . . 177

I-5,6: Utility and Cubicle ID . . . . . . . . . . . . . . . . . . . . . . . . . 180

I-7,a,b,c: Individual Letters . . . . . . . . . . . . . . . . . . . . . . . . . . 182

I-8: Custom Logo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186

N-1a,b,c,d,e,f,g: Notice Holders . . . . . . . . . . . . . . . . . . . . . . 187

N-1h: Notice Holder w/ Brochure Holders . . . . . . . . . . . . . . . 189

N-2,a,3: General Information . . . . . . . . . . . . . . . . . . . . . . . . 190

O-1a,b,c,d,e,f,g,h: Overhead, Projecting ID/Guide . . . . . . . . 193

O-2,a: Overhead ID/Guides . . . . . . . . . . . . . . . . . . . . . . . . . 195

O-3,a: Overhead Guides . . . . . . . . . . . . . . . . . . . . . . . . . . . 197

O-4a,b: Overhead, Projecting ID/Guides, Large . . . . . . . . . . . 199

O-5,b,c: Overhead Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . 201

O-6,a: Overhead ID/Guide . . . . . . . . . . . . . . . . . . . . . . . . . . 204

R-1,a: Regulatory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206

R-2: Regulatory Stairwell . . . . . . . . . . . . . . . . . . . . . . . . . . . 208

R-3: Regulatory Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209

V-1,3,4: Vinyl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210

APPENDIX 1

Wayfinding Project Objectives

2STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 3: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

STANDARDS MANUAL FOR WAYFINDING SIGNAGE

EXTERIOR AND PARKING SIGN TYPE ARRAYS

3

Page 4: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

Cx-1 Campus Identifier,Post Mounted

Illuminated

Illuminated Illuminated Illuminated Illuminated Non-illuminated Non-illuminated Non-illuminated

Illuminated Illuminated Illuminated IlluminatedNon-illuminated

Cx-2 Campus Identifier,Monument

Cx-2a Campus Identifier,Monument (48 sq ft)

Cx-4 Custom EntryOHSU Panel

Cx-5 Campus ID,with Guide

Cx-3 Logo Flame(Cx-3a Larger)

Gx-0 Extra Large Guide/Identity, Double Sided(Gx-0a Single Sided, Gx-0NI Non-illuminated)

Gx-1 Vehicular Guide, Large, Double Sided (Gx-1a Single Sided, Gx-1NI Non-illuminated)

EMERGENCY

Kohler PavilionParking A B C D

A B C D

OHSU HospitalPhysicians Pavilion

Gx-1c Vehicular Guide,w/Custom LED

A B C D

DatronicsAF-3200

OHSU HospitalEMERGENCY

Physicians Pavilion

Gx-2 Vehicular Guide,Small, Double Sided(Gx-2a Single Sided)

Kohler PavilionParking A B C D

EMERGENCY

A B C DOHSU Hospital

Gx-3 Post & Panel GuideDouble Sided

(Gx-3a Single Sided)

Kohler Pavilion

EMERGENCY

A B C D

Gx-5 Pedestrian Guide,Double Sided

(Gx-5a Single Sided,Gx-5b Wall Mounted)

Biomedical Information Communication CenterHatfield Research CenterMackenzie HallOHSU HospitalResearch Buildings

Biomedical Information Communication CenterHatfield Research CenterMackenzie HallOHSU HospitalResearch Buildings

Gx-5c Pedestrian Guide,Small, Wall Mounted

(Gx-5d Pole Strapped)

DoernbecherChildren’s Hospital

Marquam Hill Campus

Marquam HillCampus

Marquam Hil l Campus

EMERGENCY

Casey Eye InstituteDoernbecher HospitalKohler PavilionParking E F G K

A B C D

OHSU HospitalUniversityParking

South Waterfront

PParking

Vehicular guide signs are placed at points of decision along major roadways. They can also be used along long stretches to reassure drivers they are headed in the right direction. Destinations included on vehicular guide signs include Emergency, Parking, and building names. Departments and destinations interior to a building, other than Emergency, are not appropriate for this sign type.

Guide signs are limited in the number of destinations listed because drivers have a short period of time in which they can absorb the information on the sign. Destinations are grouped by arrow direction, and alphabetical within each arrow grouping. There are two exceptions to the alphabetical order, Emergency and Parking. Emergency is always the first destination within its arrow group, and Parking is the last destination within an arrow group. Arrows are organized left, right and straight ahead. When Emergency is one of the destinations on the sign, the arrow group for Emergency takes priority and is listed ahead of the other arrow groups. The arrow at the top of a destination group is always on its own line to designate direction information for the destinations below it, and arrow groups are separated by a rule line.

Campus Identifiers mark the boundary and entry points to OHSU sites. They include the full OHSU logo and the campus name. With the growing number of OHSU locations, it’s important to differentiate sites with the campus name at the vehicular entrance points.

Partner Hospital Sites: Replace the campus name with the partner hospital name.

Cx-1, Cx-2, Cx-2a and Cx-4

The logo flame is for identifying OHSU buildings from a distance. When the flame is located close to street level, it should be full color. When the flame is higher on a building, the logo should have maximum contrast to the building façade in either a solid dark grey or white.

Cx-3, Cx-3a

This sign serves the same function as the Cx-1 and Cx-2 signs by identifying the boundary and entry points to OHSU sites. It also includes general guide information and is appropriate for use at a Main Entrance or secondary campus approach.

Partner Hospital Sites: Replace the campus name with the partner hospital name.

Cx-5

Gx-0, Gx-1, Gx-2 and Gx-3The Gx-0 Extra Large Guide is used at campus entry points where there is not space for a large campus identifier, and along roads where the sign is set back from the street edge and the speed is greater than 25 mph. This sign will have limited future application, as it is larger than allowed by the Portland sign code.

The Gx-1c with LED board is for use near garage entrances to provide the opportunity to highlight temporary messages. Due to city ordinances, the use of variable-message signage is very restricted.

Gx-1 and Gx-2 sign types are to be used on single-lane roads up to 25 mph. The Gx-1 sign allows up to ten (10) spaces for arrows and destination names. The Gx-2 sign is shorter, providing seven (7) spaces for arrows and destination names.

Gx-3 sign is to be used to provide exiting information to vehicular traffic at a stop sign or within low-speed areas.

Pedestrian guide signs are utilized to provide direction to visitors once they’ve exited their vehicle. Because a pedestrian has more time to absorb the information than a driver, the text is smaller and more destinations can be included.

Partner Hospital and Clinic Sites: These signs can be used as shown. If the Gx-0 is desired, replace the logo with an approved partnership layout from the Graphic Standards. For sites without multiple patient parking areas, Parking can be alphabetized with the other destinations in the arrow group.

Gx-5 and Gx-5c

4STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 5: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

Illuminated Illuminated IlluminatedNon-illuminated

IlluminatedNon-illuminated Non-illuminated Non-illuminated Non-illuminated Non-illuminated Non-illuminated

Ix-5 Emergency Identifier

EMERG

ENCY

VALETPARKING

Ix-1 Building Identifier,Pole Mounted, HC

HatfieldResearch

Center

Use Parking C

Ix-1b Custom BuildingIdentifier,

Pole Mounted, HC

Elks Children’sEye Clinic

Casey Eye Institute

Parking E

Ix-2 Building Identifier,Wall Mounted, HC

700

HatfieldResearch

Center

Ix-2a Building Identifier,Wall Mounted, RA

BiomedicalResearchBuilding

BRB

Ix-4 Entrance Identifier,Wall Mounted

BiomedicalResearch Building

BRB

Smoking is prohibited on this campus

BRB

BiomedicalResearchBuilding

Ix-1a Building Identifier,Pole Mounted, RA

Ix-6 Individual Letters,Canopy Mounted

(Ix-6a, Ix-6b)

Ix-7 Entrance IDProjecting, Illuminated(Ix-7a Non-Illuminated)

Ix-8 Entrance ID, Panel Ix-9 Individual LettersBuilding Mounted, Illuminated

(Ix-9a Non-Illuminated)

PatientDrop-off A M B U L A N CE O N LY

This freestanding sign is used to identify the vehicular access point to Emergency. Sign may be sized to meet codes or appropriate site lines.

Partner Hospital Sites: This sign can be used as shown.

Ix-1, Ix-2, and Ix-4

Building identification signs are used to identify the building name at eye level for both vehicular and pedestrian traffic. There are two different styles of building identification. For healthcare buildings, the sign includes the full building name and either the location of preferred parking or the building address. The research and academic building identification signs have a silver footer with the three- to four-letter building abbreviation.

Ix-6

These individual letters are mounted to canopies above public entrances and drop-off locations at OHSU’s South Waterfront campus. The letters are silver during the day and illuminate white at night.

Partner Hospital Sites: Replace the entrance name with the partner hospital entrance name.

Ix-7

Flag signs like these can be used to provide guide and identification information perpendicular to traffic. The signs can be used for both pedestrian and vehicular information in areas where ground space is unavailable.

Partner Hospital Sites: These signs can be used as shown.

Ix-8

This panel entrance identification sign is for use at non-public entrances to provide general information such as Loading Dock, or Ambulance Only, etc.

Partner Hospital Sites: These signs can be used as shown.

Ix-9

Building mounted individual letters can be used to identify buildings from a distance. These letters can be used in conjunction with the OHSU logo or on their own to identify OHSU building names. Building names should use proper capitalization, not all caps.

Partner Hospital and Clinic Sites: These signs can be used as shown.

Ix-5

5STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 6: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

Non-illuminated Non-illuminated Non-illuminated Non-illuminated

Illuminated Illuminated Illuminated Illuminated Illuminated

Kx-1 Pedestrian Map Kiosk

INFORMATION

Kx-2 Pedestrian Map,Wall Mounted, Small

INFORMATION

Vx-1 Vinyl on glass(Vx-2 Large, Vx-3 Address, Vx-4 Frosted Backer)

Nx-1 Notice Plaque

BiomedicalResearch Building

BRB

Smoking is prohibited on this campus

Ix-10 Offsite Building IDVertical

Ix-10a Offsite Building IDHorizontal

Ix-11 Offsite Building IDHorizontal

Ix-11a Offsite Building IDVertical

Ix-12a, b, c, dRetrofit Panels

Ix-10c Offsite Building IDCustom

OHSU ClinicsOHSUClinics

AuthorizedPersonnel Only

See Front Security Desk for Entry

Loading Dock8:00am - 4:30pm

For assistanceplease call 503-250-2386

For after hours assistance please call 503-494-7744

OHSU Clinics

Family Medicineat Gabriel Park

4411 SW Vermont 42 12 SE Divis ion Street2415 SE 43rd

The pedestrian map kiosk is available in either a freestanding or wall mounted unit. The map shall be oriented based upon the placement of the kiosk so that the top of the map is what the user will see directly in front of them. This sign type is should be placed in an area with sufficient ambient light.

Partner Hospital Sites: This sign can be used as shown.

These free-standing monument signs are used to identify OHSU Clinic locations. Signs should always include the street address.

Partner Clinic Sites: Alternate layout options are shown on the design intent drawing pages for how to apply the partnership layout and clinic information.

Ix-10, Ix-10a, Ix-10c

These cabinet signs are appropriate for identifying an OHSU clinic building. Designs include a horizontal and a vertical layout. Sign may be scaled up or down to meet codes and fit the building space.

Partner Clinic Sites: Alternate layout options are shown on the design intent drawing pages for how to apply the partnership layout and clinic information.

Ix-11, Ix-11a

Often replacing panels on existing signs is required, especially for leased spaces. This sign type provides a number of fabrication options to meet the existing sign fabrication process. Panels are to be sized based upon the existing sign cabinet.

Partner Clinic Sites: Alternate layout options are shown on the design intent drawing pages for how to apply the partnership layout and clinic information.

Ix-12

Kx-1, Kx-2

This sign is for use to display general and caution information in the exterior environment.

Partner Hospital Sites: This sign can be used as shown.

Nx-1

Vinyl graphics are to be used at public entrances to identify the building, general service line, address or hours of operation. A listing of physicians or all interior destinations is not appropriate for exterior display.

Partner Clinic Sites: Alternate layout options are shown on the design intent drawing pages for how to apply the partnership layout and clinic information.

Vx-1, Vx-2, Vx-3, Vx-4

Family Medicine at Richmond3930 SE Division Street

6STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 7: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

Non-illuminated Non-illuminated Non-illuminated

Illuminated Illuminated Illuminated IlluminatedIlluminatedNon-illuminated Non-illuminated

Px-1 Garage Identifier,Free Standing, Large

Patients and Visitors park here for:

Hatfield Research Ctr

OHSU Hospital

Sam Jackson Hall

D

Visitor ParkingP

Px-1a Garage Identifier,Free Standing, Large

Park here for:

DoernbecherChildren’s Hospital

OHSU Hospital

D

Visitor ParkingP

FULLOPEN

Px-1b Garage Identifier,Free Standing, Large w/ Display

Park here for:

DoernbecherChildren’s Hospital

OHSU Hospital

D

FULLOPEN

DatronicsAF-3200

Px-2 Garage Identifier,Wall mounted

Park here for:

DoernbecherChildren’s Hospital

OHSU Hospital

D

Visitor ParkingP

Px-2b Garage Identifier, Projecting(Px-2c Wall Mounted)

Park here for:

DoernbecherChildren’s Hospital

OHSU Hospital

D

FULLOPEN

DatronicsAF-3200

Px-2d Garage Identifier,Wall Mounted

Park here for:

DoernbecherChildren’s Hospital

OHSU Hospital

D

Visitor ParkingP

Px-2e Garage Identifier,Projecting, Small

Px-3 Garage Identifier,Bulkhead Mounted

A Park here for:

Emma Jones Hall

Px-4 Parking Identifier,Free Standing, Small

APark here for:

Emma Jones Hall

Visitor ParkingP

Px-5 Staff Lot Identifier,Free Standing

10Staff

Parking

Center forHealth & Healing

P OPENFULL

Px-1These sign types are used for parking garages or lots that service public and non-public parking. They are meant to be installed perpendicular to the path of traffic accessing the parking. In addition to providing information for the nearest building access points, they also include an area (either LED board or changeable message panel) where temporary messages can be displayed. Due to city ordinances, the use of variable-message signage is very restricted.

There are several options for parking identification based upon the built environment, type of parking and the vehicular approach to the parking entrance.

Partner Hospital Sites: All of these parking signs can be used as shown, but replace the alpha character with the universal Parking symbol.

Px-4This is a smaller version of the Px-1 freestanding identification sign, and is suitable for use at less public parking opportunities, and for lots that only service one building. The changeable message panel at the bottom is to be used to provide temporary parking designation information for special events.

Px-3 These sign types are for smaller garage access points where a visitor drives straight into the entrance and there is no space available for the freestanding Px-1 sign type. This sign can also be used in conjunction with a Px-1 sign to help identify specific level entrance points, or when the garage entrance is set back from the access drive.

Px-2These sign types are specifically designed for parking garages, where the sign can be installed either projecting from the wall or on the wall next to the vehicular entrance. These signs provide confirmation of which buildings are best accessed via the given garage and they include an area (either LED board or changeable message panel) where temporary messages can be displayed. Due to city ordinances, the use of variable-message signage is very restricted.

Px-5This is for use at non-public surface parking lots. This sign incorporates the changeable message panel to provide temporary parking designation information for special events.

7STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 8: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

Illuminated Illuminated Non-illuminated Non-illuminated

Non-illuminatedNon-illuminatedNon-illuminatedNon-illuminated Non-illuminated

Non-illuminated

Px-6 Garage Entrance Identifier,Wall-mounted

Px-6a Garage Exit Identifier,Wall-mounted

Px-6d Garage Clearance Bar

E XIT ONLY

0'-0" Clearance

ENTR ANCEP P

Px-8 Overhead Guide, Long,Px-8a Overhead Guide, Beam Mounted, Long,

Px-8.2 Overhead Guide, Suspended, Long, Double-sided

Px-8b Overhead Guide, Suspended, Long (10"),Px-8c Overhead Guide, Beam Mounted, Long (10"),

Px-8b.2 Overhead Guide, Suspended, Long (10"), Double-sided

Px-9 Overhead Guide, Suspended,Px-9a Overhead Guide, Beam Mounted,

Px-9.2 Overhead Guide, Suspended, Double-sided

Px-9b Overhead Guide, Suspended (10”),Px-9cv Overhead Guide, Beam Mounted (10”),

Px-9b.2 Overhead Guide, Suspended, Double-sided (10”)

Px-10 Overhead Two Way Traffic, Suspended,Px-10a Overhead Two Way Traffic,

Beam Mounted

Two-way Traffic

Px-11 Overhead Clearance, SuspendedPx-11a Overhead Clearance, Beam Mounted

Px-11b Overhead Entrance/Clearance, Suspended

0'-0" Clearance

Caution: Clearance Change

Px-12 Overhead Guide, Pedestrian Elevator, Suspended,Px-12a Overhead Guide, Pedestrian Elevator, Beam Mounted

Px-12b Double-sided

Elevator s

Elevator s

Parking

Right Turn Only

Parking Exit

Parking

Right Turn Only

Parking

No Exit

Parking

No Exit

7'-0" Clearance – 8'-2" Accessible Clearance

Px-6 and Px-6aThese wall-mounted signs are used to identify the vehicular entrance and exit points of a parking garage structure. The entrance signs incorporate a clearance bar that identifies the minimum clearance height within a parking garage. Entrance and exit signs are also available as non-illuminated with reflective graphics (Px-7 and Px-7a).

Px-8These overhead mounted signs provide vehicular direction for parking and exit information as well as necessary regulatory information. Signs are available as suspended single-sided, suspended double-sided or beam mounted. They are also available in long and short versions to provide options for different garage clearance height situations.

Px-10This overhead mounted sign is available in a suspended or beam mounted version. The sign is used to warn drivers of two-way traffic or pedestrian crossing points.

Px-11This overhead mounted sign provides warning information of clearance height changes. This is available for either beam-mounting or suspended mounting. Sign should be strategically placed to allow taller vehicles the opportunity to turn around, but not block spaces for the taller vehicles prior to the clearance change.

Px-12These overhead beam-mounted or suspended signs are smaller than vehicular overhead signs, and are used to provide wayfinding information or caution information to pedestrian traffic within a parking garage. Elevator identification should be placed perpendicular to the pedestrian traffic at or near each elevator lobby.

Px-9These overhead mounted signs provide vehicular direction for parking and exit information as well as necessary regulatory information. Signs are available as suspended single-sided, suspended double-sided or beam mounted. They are also available in long and short versions to provide options for different garage clearance height situations.

8STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 9: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

Non-illuminated Non-illuminated Non-illuminated Non-illuminated Non-illuminated Non-illuminated Non-illuminated Non-illuminatedIlluminated

Non-illuminatedNon-illuminated Non-illuminated Non-illuminated Non-illuminated Non-illuminated Non-illuminated Non-illuminated Non-illuminated

Px-14 Elevator Level Identifier

PORTLANDIA

PARKING GAR AGE

Px-15 Level Identifier

LIGHTHOUSE

GARAGE C

Px-15a Level IdentifierGuide (One Line)

Px-15b Level IdentifierGuide (Two Lines)

(Px-d, Px-e No Icon)

Px-16 Elevator Cab Level Identifier

To reach the hospital,exit on Level 1.

FALLS

CAMPUS DRIVE GARAGE

TEALP5YELLOWP6

PURPLEP1ORANGEP2

GREENP3REDP4

BLUEP7BROWNP8

Px-17 Vehicular Guide,Column Mounted

PARKINGONE WAYTRAFFIC

Px-20 Electronic Level Sign(Px-20a Wall Mounted)

P8 - Permit

P7 - Permit

P6 - Permit

P5 - Permit

P4 - Metered Parking

P3 - Metered Parking

P2 - Patient & Visitor

P1 - Patient & Visitor

F

Rx-1 Regulatory,Wall Mounted

(Rx-3 Pole Mounted)

ReservedParking

PhysiciansOnly

ReservedParking

PhysiciansOnly

Rx-2 Regulatory,Ceiling Mounted, Single Panel

(Rx-2a Two Panel)

Rx-4 Barrier Free, Double Sided(Rx-4a Single sided, Rx-4b Wall Mounted

Rx-4c Pole Mounted)

AccessiblePath

AccessiblePath

Rx-6 Regulatory,Campus Boundary

(Rx-6a Pole Mounted)

Rx-6a RegulatoryPole-Mounted, Tall

LIGHTHOUSE

GARAGE C

E levator s

STAIR 1stair 1

Rx-5 Regulatory Rx-5a RegulatoryStairwell

Rx-7 Parking Rates

Entering OHSUCampus Property

Campus Drive and the sidewalksare within OHSU property

Entering OHSUCampus Property

Campus Drive and the sidewalksare within OHSU property

Px-14a Elevator LevelIdentifier, Small

(Px-14b No Icon)

P1LEVEL

LIGHTHOUSE

GARAGE C

LIGHTHOUSE

Center for Health& Healing Garage

P1LEVEL

BUILDING

Px-16a Elevator LobbyLevel Identifier, Large

Center for Health & Healing

Building 1

To access Building 1,exit on Floor 1 and

take the visitor elevator.

PURPLELEVEL P1

GREENLEVEL P3

ORANGELEVEL P2 Valet

Lobby & Street AccessFLOOR 1

March Wellness & Fitness CenterFLOOR 2

ReservedParking

PhysiciansParking Only

STAIR 1ROOF ACCESS

91 THROUGH ROOFEXIT THIS LEVEL

PHourly Rate: $X.XX

Daily Max Rate: $X.XXPatient Validation Rate: $X.XX

Lost Ticket Fee: $X.XX

No motorcycle, bicycle or pedestrian traffic.

Parking Rates

LIGHTHOUSE

GARAGE C

E levator s

Sta i r s

Guest HouseElevator

Parking Elevator

LEVEL P2Building 2Bui ld ing

LEVEL

Hourly Rate: $X.XXDaily Max Rate: $X.XX

Patient Validation Rate: $X.XXLost Ticket Fee: $X.XX

No bicycle orpedestrian traffic.

Knight CancerResearch Building

Permit ParkingOnly

Px-18 RememberYour Ticket

Pay Stations AreLocated In The Lobby

Take Your TicketWith You

Px-14Aluminum signs with digitally printed reflective graphics are used at public elevator banks to remind pedestrians what level they parked on and which garage they are in. These are to be placed either next to the elevator when the elevator is directly on vehicular and pedestrian paths, or on the outside of the elevator lobby when there is a vestibule that the pedestrian enters to access the elevator.

Px-15Aluminum panels with digitally printed reflective vinyl graphics are used to provide reinforcement of the parking level and garage. Signs are to be placed on the columns and back walls of parking spaces. Within public parking areas, they should be spaced about every 3 columns staggered along both sides of the drive aisle. Within staff parking areas, signs should be placed at both ends of the drive aisle and once within the center of the aisle. Because these signs provide reinforcement information for pedestrian traffic after they’ve exited their cars, placing the signs where parked cars may block them from the drive lane is not a concern.

The Px-15a or Px-15b can be used to provide pedestrian traffic direction to elevators, stairs, valet, and building or bridge access. The Px-15a allows one line of directional information. The Px-15b allows for two lines of information. These are particularly helpful when the elevators or bridges are easily identifiable.

Px-16This frame sign includes a large format printed insert. It outlines the parking levels within the given garage, including information about building entrances or bridges. This sign is located within each elevator cab and at the call buttons for the elevator or on the landings within parking garage stairwells. When within the garage or stairwell, a rigid insert with exterior grade inks shall be used.

Px-17This column mounted aluminum panel with reflective graphics provides vehicular guide information. This sign is mounted to the face of a column that is perpendicular to traffic. It is not to be used on the sides of columns where parked traffic can block the messaging. In order to minimize over-signing within a parking garage, it is recommended that this sign not duplicate information provided on overhead Px-8 and Px-9 signs, but be used only where those signs would not be visible.

Px-18Place this sign throughout a garage where a visitor must pay for their parking before exiting or have their ticket validated.

Rx-1, Rx-2, Rx-3, Rx-4 and Rx-5 A series of small post-and-panel sign options have been provided as part of this standard for providing general information such as reserved parking, accessible path or accessible entrance directions, directions to the Tram, or regulatory information.

Rx-6Use the campus boundary sign as required to mark the entrances to OHSU property. Freestanding and wall/fence mounted options have been provided.

Rx-7When information needs to be provided to the vehicular drive prior to entering the garage, the Rx-7 sign can be used. Designed for displaying parking rates, the large removable insert panel allows for easy changeability as rates and functions change.

Px-20These one-sided electronic signs are used within parking garages that have electronic counting systems. The sign indicates either the number of spaces available on each level, or whether the level is full or open. Messaging and digital displays appear on one side of the sign only.

9STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 10: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

STANDARDS MANUAL FOR WAYFINDING SIGNAGE

INTERIOR SIGN TYPE ARRAY

10

Page 11: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

STANDARDS MANUAL FOR WAYFINDING SIGNAGE

D-1 Main Directory, Freestanding, W/handheld Map D-1a Main Directory, Wall Mounted, W/handheld Map D-2 Main Directory, Free Standing D-2a Main Directory, Wall Mounted

D-2b Main Directory, Freestanding, Angled, W/handheld Map D-2c Main Directory, Wall Mounted, Simplified D-2d Main Directory, Freestanding, Tall-angled,with handheld Map, Small

D-2f Main Directory, Wall Mounted, Simplified

D I R E C T O R YD I R E C T O R Y

O H S U H O S P I T A L • M A R Q U A M H I L L C A M P U S

D I R E C T O R YD I R E C T O R Y

O H S U H O S P I T A L • M A R Q U A M H I L L C A M P U S

D I R E C T O R YD I R E C T O R Y

H O S P I T A L • M A R Q U A M H I L L C A M P U S H O S P I T A L • M A R Q U A M H I L L C A M P U S

D I R E C T O R YD I R E C T O R Y

D I R E C T O R YD I R E C T O R Y

O H S U H O S P I T A L • M A R Q U A M H I L L C A M P U S

D I R E C T O R YD I R E C T O R Y

S A M J A C K S O N H A L L • M A R Q U A M H I L L C A M P U S

D I R E C T O R YD I R E C T O R Y

H A T F I E L D R E S E A R C H C E N T E R

D I R E C T O R YD I R E C T O R Y

B A I R D H A L L • M A R Q U A M H I L L C A M P U S

D-1, D-1a, D-2, D-2a-fLocated near building entrances or at transition points between connecting buildings, these freestanding or wall-mounted directories provide the “universe of information” available to patients and visitors. The directory includes a listing of destinations accessible within that building, organized alphabetically into two sections, first destinations and then patient units. When connected to other buildings, there is a third section that includes instructions on how to access those other buildings. The directory also includes a map of the current floor showing public pathways and elevators.

11

Page 12: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

STANDARDS MANUAL FOR WAYFINDING SIGNAGE

D-3 Elevator Directory Decorative D-3a Elevator Directory D-3b Elevator Directory, Inside Cab D-3c Elevator Directory, Inside Cab D-3e Physician Directory

D-4 Strip Map W/ Guide Info, Decorative D-4a Strip Map, Decorative D-4b Strip Map W/guide Info D-4c Strip Map D-5 Transitional Elements

Floor 9

H O S P I TA LE L E VAT O RB

Use these elevators to access thefollowing destinations.

Cafe 9

Care Management 9

Center for Learning/Development 14

Clinical Technology Services 1

CT Scan 8

Diagnostic Radiology 10

EMERGENCY 8

Environmental Services 1

Express Admit Unit 5

Facilities Operations 1

Food & Nutrition 3

Gift Shop 9

Hemodialysis 4

Hospital Administration 8

Information 9

MRI 10

Rehabilitation Services 8

Patient Access Services 9

Patient Advocate 9

Radiology 10

Volunteer Services 9

DESTINATION FLOOR

Floor 10

MULTNOMAHELEVATORAUse these elevators to access thefollowing destinations.

Cafe 9

Care Management 9

Center for Learning/Development 14

Clinical Technology Services 1

CT Scan 8

Diagnostic Radiology 10

EMERGENCY 8

Environmental Services 1

Express Admit Unit 5

Facilities Operations 1

Food & Nutrition 3

Gift Shop 9

Hemodialysis 4

Hospital Administration 8

Information 9

MRI 10

Rehabilitation Services 8

Patient Access Services 9

Patient Advocate 9

Radiology 10

Volunteer Services 9

DESTINATION FLOOR

Use this elevator to access thefollowing destinations.

Cafe 9

Care Management 9

Center for Learning/Development 14

Clinical Technology Services 1

CT Scan 8

Diagnostic Radiology 10

EMERGENCY 8

Environmental Services 1

Express Admit Unit 5

Facilities Operations 1

Food & Nutrition 3

Gift Shop 9

Hemodialysis 4

Hospital Administration 8

Information 9

MRI 10

Rehabilitation Services 8

Patient Access Services 9

Patient Advocate 9

Radiology 10

Volunteer Services 9

Orthopedics 10

Ultra Sound 10

DESTINATION FLOOR

Use this elevator to access thefollowing destinations.

Cafe 9

Care Management 9

Center for Learning/Development 14

Clinical Technology Services 1

CT Scan 8

Diagnostic Radiology 10

EMERGENCY 8

Environmental Services 1

Express Admit Unit 5

Facilities Operations 1

Food & Nutrition 3

Gift Shop 9

Hemodialysis 4

Hospital Administration 8

Information 9

DESTINATION FLOOR PHYSICIANS LISTINGCafe 9

Care Management 9

Center for Learning/Development 14

Clinical Technology Services 1

CT Scan 8

Diagnostic Radiology 10

EMERGENCY 8

Environmental Services 1

Express Admit Unit 5

Facilities Operations 1

Food & Nutrition 3

Gift Shop 9

Hemodialysis 4

Hospital Administration 8

Information 9

MRI 10

Rehabilitation Services 8

Patient Access Services 9

Patient Advocate 9

Radiology 10

Volunteer Services 9

Orthopedics 10

Ultra Sound 10

Cafe 9

Care Management 9

Center for Learning/Development 14

Clinical Technology Services 1

CT Scan 8

Diagnostic Radiology 10

EMERGENCY 8

Environmental Services 1

Express Admit Unit 5

Facilities Operations 1

Food & Nutrition 3

Gift Shop 9

Hemodialysis 4

Hospital Administration 8

Information 9

MRI 10

Rehabilitation Services 8

Patient Access Services 9

Patient Advocate 9

Radiology 10

Volunteer Services 9

Orthopedics 10

Ultra Sound 10

D-3f Custom Elevator Directory

Floor 3

G HATFIELD ELEVATORUse these elevators to access the following destinations.

Cafe 9

Care Management 9

Center for Learning/Development 14

Clinical Technology Services 1

CT Scan 8

Diagnostic Radiology 10

EMERGENCY 8

DESTINATION FLOOR DESTINATION FLOOR

Environmental Services 1

Express Admit Unit 5

Facilities Operations 1

Food & Nutrition 3

Gift Shop 9

Hospital Administration 8

Information 9

D-3g Elevator Directory

Floor 1

SCHOOL OF NURSINGELEVATOR

Use these elevators to access thefollowing destinations.

Cafe 9

Care Management 9

Center for Learning/Development 14

Clinical Technology Services 1

CT Scan 8

Diagnostic Radiology 10

EMERGENCY 8

Environmental Services 1

Express Admit Unit 5

Facilities Operations 1

Food & Nutrition 3

Gift Shop 9

Hemodialysis 4

Hospital Administration 8

Information 9

MRI 10

Rehabilitation Services 8

Patient Access Services 9

Patient Advocate 9

Radiology 10

Volunteer Services 9

DESTINATION FLOOR

Cafe

Elevators

Gift Shop

Information

Public Pathways

Restrooms

Hospital CElevators

ToDoernbecherChildren’sHospital

SurgeryWaiting

Patient Relations

ToKohler PavilionTram

YouAreHere

C

Information

DoernbecherChildren’sHospital

Hatf ieldResearch Ctr

KohlerPavilion

Tram

You are in the Hospital Floor 9

Cafe

Elevators

Gift Shop

Information

Public Pathways

Restrooms

Hospital CElevators

ToDoernbecherChildren’sHospital

SurgeryWaiting

Patient Relations

ToKohler PavilionTram

YouAreHere

C

Information

You are in the Hospital Floor 9

Cafe

Elevators

Gift Shop

Information

Public Pathways

Restrooms

Hospital CElevators

ToDoernbecherChildren’sHospital

SurgeryWaiting

Patient Relations

ToKohler PavilionTram

YouAreHere

C

Information

DoernbecherChildren’sHospital

Hatf ieldResearch Ctr

KohlerPavilion

Tram

You are in the Hospital Floor 9

Cafe

Elevators

Gift Shop

Information

Public Pathways

Restrooms

Hospital CElevators

ToDoernbecherChildren’sHospital

SurgeryWaiting

Patient Relations

ToKohler PavilionTram

YouAreHere

C

Information

You are in the Hospital Floor 9

H AT F I E L D R E S E A R C H C E N T E R

D-3eThe physician directory listing is an alphabetical by last name listing of physicians. The directory can be used at a suite entrance, or at a building entrance.

D-3, D-3a, D-3f, D-3gThis wall mounted sign type is located at every public elevator bank and lists the public destinations that are accessible via that elevator, along with the floor where the destination is located. The directory should be located on the same wall as the elevator doors and call buttons. Destinations are separated between public destinations and patient units, and listed alphabetically within each group.

The decorative version of the elevator directory (D-3) is only used on the ninth floor of the Hospital, Kohler and Hatfield buildings. The standard directory units are to be used in all other instances.

D-3b, D-3cThese inside cab elevator directories are the same as the D-3a directories, but are located inside of the elevator cab rather than in the elevator lobby. Destination listings and organization should match the elevator directory in the lobbies.

D-4These wall-mounted sign types indicate the current floor and depicts a simplified version of the floor plan, showing symbols and destinations that are nearby. The user’s location is marked with a “You Are Here” arrow. The map should be correctly oriented to the viewer, so that the top of the map shows the direction that the viewer is facing. The D-4 and D-4b signs also contain a second insert with at-a-glance directional information for nearby buildings and the tram only. This sign type is to be used within long corridors to reinforce one’s location and direction, or at complex decision points.

The more decorative version of the D-4 and D-4a are for use on the ninth floor of the Hospital, Kohler and Hatfield buildings only. The D-4b and D-4c are to be used in all other locations.

D-5This custom overhead is to be used to mark when a visitor transitions from one building to another. When the building transition includes a change in floor, include the new floor information as well.

12

Page 13: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

STANDARDS MANUAL FOR WAYFINDING SIGNAGE

G-1 Guide Sign, Large, Decorative G-1a Guide Sign, Medium, Decorative G-1b Guide Sign, Small, Decorative G-2 Guide Sign, Large G-2a Guide Sign, Medium G-2b Guide Sign, Small

G-3 Guide Sign, Freestanding G-4a Guide Sign, Customretrofit of existing sign.

I-1 Primary Identifier, Decorative I-1a Primary Identifier,with slider, Decorative

I-1b Primary Identifier I-1c Classroom/lab Identifierwith Notifier Bar

Floor 9

EMERGENCY Elevator

Conference Room 9D53Hatfield ElevatorHospital AdministrationMarquam CaféRestroom

G

Floor 9

Stairs toEMERGENCY

To OHSU Hospital

Floor 9

Hospital Administration

Conference Room 9D53Marquam CaféRestroomTo OHSU Hospital

Floor 1

Library ResearchAdministration

To OHSU HospitalTo Parking Garage

Floor 2

Movement DisordersProgramParkinson Center of OR

To Multnomah Pavilion

Floor 5

Division of VascularSurgeryMultnomah ElevatorA

Kohler OutpatientElevatorPatient Rm 9020-9144To Parking Garage

Floor 9

Floor 9

EMERGENCY Elevator

Hatfield Elevator

Hatfield Elevator

Hospital Administration

Marquam Café

Gift Shop

Hospital Elevator

E

G

PhysicalTherapyTerapia física

PHYSIC AL THER APYHEALTH CONNECTIONS

ConferenceRoom 9D53

CONFERENCE ROOM 9D53HEALTH CONNECTIONS

In Use

Pharmacy

PHARMAC YHEALTH CONNE

ResearchAdministration

RESEARCH ADMINISTR ATIONHEALTH CONNECTIONS

Classroom8N124

8 N124

G-1, G-1a, G-1b, G-2, G-2a, G-2b, G-3These sign types are used to direct to elevators and nearby primary and secondary public destinations. Guide signs are located at key decision points or within long corridors where confirmation of direction is needed. The large version of this sign frame has space for up to 11 arrow and destination lines, the medium has space for up to 9 arrow and destination lines, and the small frame can display up to 7 arrows and destination lines. Destinations shall be listed in the following order - left, right, then straight ahead. Destinations within each arrow group are listed alphabetically. If an arrow grouping includes Emergency, then that arrow group is listed first, and Emergency is the first destination.

The more decorative G-1 sign types are to be used on floor 9 of the Hospital, Kohler and Hatfield buildings only. The G-2 family is for use everywhere else. The G-3 sign type can be used on any floor, and is to be used in locations where a visitor needs guide information, but there is no wall space available for a wall-mounted sign.

I-1, I-1a, I-1b, I-1c, I-1d, I-1eThis wall-mounted sign type displays the name of a primary public destination and repeats the name in tactile and Braille lettering. Only the top 10-15% of destinations will receive this high-level sign type. This sign is to be placed at the entrance to the destination and mounted in accordance with ADA requirements. International symbols from the graphic standards page are used where appropriate.

The more decorative I-1 and I-1a sign types are to be used on floor 9 of the Hospital, Kohler and Hatfield buildings only. The remaining options are for use everywhere else.

13

Page 14: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

STANDARDS MANUAL FOR WAYFINDING SIGNAGE

I-1d Classroom/lab Identifierwith Insert

I-1e Primary IdentifierW/letter Sized Insert Holder

I-2 Secondary Identifier I-2a Conference Room Identifierwith insert Holder

I-3 General Room Identifier

I-4 Patient Room Identifier I-5 Utility Identifier I-6 Cubical Identifier I-7 Individual Letters

Classroom8N124

8 N124SJFGHZSJHGJHG

Cafeteria

C AFETERIAHEALTH CONNE

Patient &Family Lounge

247 8GJHG

Kenneth C. SwanLibrary

247 8GJHG

Hours:Monday-Thursday8:00am-4:00pm

Reserved for faculty and staff.

6 7 8GJHDFG

Office

3453 4 52478

Leah CuddingtonAssistant

FACILITIES SVCS WORKSHOP

4 N 0 81BT I S S U E C U LT U R E

I-1d and I-1eThe I-1d includes a half-letter sized insert holder within the sign frame to allow for added messaging, such as classroom notices, hours of operations, or other special instructions. The I-1e includes a letter-sized insert holder and is similarly used for additional information that is pertinent to the patient or visitor.

I-4This small wall-mounted sign type displays the number of the patient room in tactile and Braille characters.

I-7, I-7a, I-7b and I-7cThis sign type is used to identify high-level public destinations in highly visible public areas such as registration and information desks and entrances to major departments.

I-2 and I-2aThese slightly smaller wall mounted identification signs are to be used at more secondary public destinations. The sign is to be placed at the entrance to the destination in accordance with ADA regulations. The I-2a sign is especially appropriate for use at conference rooms, where the lower insert holder can be used to post the room reservation schedule.

I-3This smaller room identification sign is to be used at offices and non-public or back-of-house destinations. The tactile/Braille panel should be used to display the room number.

I-6Nameplate signs identify staff office spaces where tactile and Braille are not required by code. When identifying an office, the copy on this sign should be limited to the occupants name and title.

I-5This small wall-mounted identification sign is used to designate utility type rooms such as telecommunication, electrical, housekeeping, etc.

14

Page 15: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

STANDARDS MANUAL FOR WAYFINDING SIGNAGE

N-1a Notice Holder N-1b Notice Holder N-1c Notice Holder N-1d Notice Holder N-1e Notice Holder N-1f Notice Holder N-1g Notice Holder

N-2 General Information N-2a General Information

Please lockthe door.

Please lockthe door.

Accessible Path to Hospital

Take Elevator toLobby to access

DoernbecherChildren’s Hospital.

Cell phones may interfere with patient care equipment.

No cell phones in this area.

N-2 and N2aThese simple flat acrylic sign types are used to convey information such as restricted access or special instructions.

N-1a-fThese simple wall-mounted, desktop and freestanding signs are used to display general information notices in various sizes and orientations.

15

Page 16: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

STANDARDS MANUAL FOR WAYFINDING SIGNAGE

O-1e Projecting Identifier, Small,Ceiling Mount

4

O-1a Projecting Identifier, Large,Ceiling Mount

HospitalElevator

O-1f Projecting Identifier, Small,Wall Mount

4

O-1d Projecting Identifier, Medium,Wall Mount

O-1c Projecting Identifier, Medium,Ceiling Mount

AngioLab 1

O-1g Projecting Identifier,Ceiling Mount

E

O-1h Projecting Identifier,Wall Mount

E

O-1b Projecting Identifier, Large,Wall Mount

HospitalElevator

O-2 Overhead Identifier/guide, Double-sided, Ceiling Mounted,O-2a Overhead Identifier/guide, Single-sided, Wall Mounted

Casey Eye Elevator

O-2, O-2aOverhead identifier signs are used to highlight high-level public destinations. These are primarily used to identify public elevators and the top 10% of the public destinations.

O-1a-h, O-4aThese two-sided sign types project from the wall, or hang from the ceiling near the wall, and use text and symbols to identify the location of key public destinations and resources. These signs should be used at locations where there are adequate sight lines.

KohlerOutpatientElevator

O-4a Projecting Identifier/guide,Ceiling Mounted

16

Page 17: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

STANDARDS MANUAL FOR WAYFINDING SIGNAGE

O-3 Guide, Large, Double-sided, Ceiling Mounted,O-3a Overhead Guide, Large, Single-sided, Wall Mounted

Elevator to ParkingTo OHSU Hospital

O-5b Overhead Guide, Double-sided,Ceiling Mount

Diagnostic Imaging Rheumatology &Immunology InfusionOrthopaedics & Rehab

O-5 Overhead Guide, Double-sided,Ceiling Mounted

Day Stay Surgery Admit/WaitingDoernbecher Ambulatory SurgeryShort Stay UnitTo Sam Jackson Hall

R-1 Regulatory

WOMEN2478

EXIT STAIRS2478FDVBSDF

BIOHAZARDBIOHAZARD

RADIATIONRADIATION

R-3 RegulatoryR-1a Regulatory

WOMEN2478

Changing TableAvailable

R-2 Regulatory Stairwell

O-3, O-3a, O-5, O-5bThese overhead signs are used to direct to high-level destinations at key decision-making points where adequate sight lines are available and a wall guide at standard height cannot be used to provide the direction. Their use should be minimized as people, particularly the elderly, tend to avoid looking up for directions. The O-3 sign face can display upto two destinations, whereas the O-5 and O-5b signs can hold upto four destinations per sign face. Destinations should be listed left, then right, then straight-ahead. If both destinations are in the same direction, they should be listed alphabetically.

R-1, R-1a, R-2 and R-3This collection of sign types are used to comply with code requirements for the identification of restrooms, stairs, warning labels, or interior stairwell instructions. Fire codes, building codes, ADA, and other regulations dictate the placement and use of these signs.

LEVEL V1

★ F L O O R 1

STAIR 1ROOF ACCESS

91 THROUGH ROOFEXIT THIS LEVEL

17

Page 18: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

STANDARDS MANUAL FOR WAYFINDING SIGNAGE

EXTERIOR AND PARKING DESIGN INTENT DRAWINGS

18

Page 19: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

Fabrication Specifications

A. Quality StandardsThe materials, products, equipment and performance specifi cations described within, establish a standard of required function, dimension, appearance, performance and quality to be met by the Fabricator.

B. Structural DesignDetails on design intent drawings indicate a design approach for sign structure but do not necessarily include all fabrication details required for the complete structural integrity of the signs, including consideration for static, dynamic and erection loads during handling, erecting, and service at the installed locations, nor do they necessarily consider the preferred shop practices of the individual Fabricators. Therefore, it shall be the responsibility of the Fabricator to perform the complete structural design and engineering of the signs and to incorporate all the safety features necessary to adequately support the sign for its intended use and purpose and to protect the Owner. Fabricator shall also be responsible for ensuring that all signs meet local, state and federal codes.

C. Vandalism DesignFabrication and installation design is to withstand severe abuse and souvenir theft vandalism, but not less than the equivalent of resisting simple hand implements and tools (screwdrivers, knives, coins, keys, and similar items), and adult physical force. All hardware and fasteners within reach shall be vandal resistant.

D. SubstitutionNo substitution will be considered unless the Owner has received written request for approval. Fabricator may recommend equal or better equipment or method, but will be required, prior to the bid submittal, to provide full documentation establishing such a substitution’s equality or superiority as measured in the following:

• compliance with the visual design intent;• cost;• ease of maintenance; and • performance.

The burden of proof of the merit of the proposed substitute is upon the Fabricator. The Owner’s decision of approval or disapproval of a proposed substitution shall be fi nal.

E. Material HandlingThe Fabricator is to pack, wrap, crate, bundle, box, bag, or otherwise package, handle, transport, and store all fabricated work as necessary to provide protection from damage by every cause. Fabricator shall provide clear and legible identifying information on all product packaging to ensure proper on-site identifi cation and installation.

F. Sign Specifi cations: Construction MethodologyThe drawings call for a variety of fabrication techniques. Fabricators are given leeway to fabricate the signs to meet the intent of the designs depicted by the drawings.

1. Because different systems of extrusions may result in slightly different dimensional requirements, the total height and width dimensions described in the sign construction on the drawings may be considered “nominal” for the purposes of cost quote.

2. Sign faces are to be fabricated using aluminum plate of varying thicknesses, as specifi ed on design intent drawings, with a minimum thickness of .125 inches unless otherwise noted.

3. Sign cabinet seams shall be sealed to ensure they are watertight.

4. All fi nishes are to be satin fi nish, free from fading, peeling or cracking. Paint preparation of all exterior metal surfaces of the sign to include removal of all scratches and imperfections, sanding and chemical etching. Substrate cleaning, preparation, paint application and paint thickness to be in strict compliance with Matthews Paint or AkzoNobel published recommendations. Acceleration of the drying process is not allowed.

5. Unless otherwise noted on the design intent drawings, all cut-out push-through lettering and shapes shall be routed from a single sheet of white acrylic, with a minimum thickness of 3/8” and pushed through 1/16”. Routed letters and shapes that are bonded to a separate acrylic sheet are not acceptable; they must be routed from a single sheet.

• Acrylic is to be attached to the back of the sign using adhesive, mechanical fasteners, or both depending on the design specifi cations.

• All letter knock-outs (interior of letter forms) are to be stud mounted through the acrylic.

• When illuminating the acrylic face with LED, 2447 shall be the standard white acrylic.

• Acceptable spacing between the push-through acrylic and the cut-out aluminum is 1/32” to 1/16” depending on the copy height (if the copy is larger than 32”, alternate spacing may be used to allow for the change in material expansion).

6. Except where approved otherwise by Owner, conceal fasteners.

7. Exposed welded joints must be fi lled and ground smooth so that there is no seam visible when painted.

8. Any sign faces smaller than 8’ by 20’ are to be fabricated from 1 piece of seamless material.

9. On welded joints, dimensional and structural welding defects will not be accepted, including but not limited to: poor weld contours, including excessive bead convexity and reinforcement, and considerable concavity or undersized welds; cracks; undercutting; porosity; incomplete fusion; inadequate penetration; spatter; and non-metallic inclusions. Welding is to be performed by AWS (or similar) certifi ed personnel, following AWS Standard Welding Procedure Specifi cations (SWPSs) for steel, aluminum, and stainless steel as appropriate.

10. Non-welded joints between various portions of signs must have a tight, hairline-type appearance, without gaps. Provide suffi cient fastenings to preclude looseness, racking, or similar movement.

11. Provide drain holes as needed to prevent accumulation of water within signs. Holes must be inconspicuous and be in inconspicuous locations; holes must be located such that drainage does not occur onto signs, or other surfaces subject to staining. Provide internal system of baffl es to prevent “light leaks” through drain holes of

illuminated signs. Provide color-coordinated insect screening over drain holes.

12. Non-illuminated sign faces are to have lettering and graphics created as mask and spray or surface-applied vinyl typography using Avery or 3M exterior grade, minimum 5-year warranty. Certain applications are to be engineer-grade refl ective vinyl as specifi ed on the design intent drawings.

13. Visible metal joints must adhere to a fi t tolerance of .01”.

14. Unlit channel letter faces must be .25” aluminum. Channel letter returns must be .080” aluminum.

G. Sign Specifi cations: Illumination & Electrical1. It shall be the responsibility of the sign fabricator to perform the complete electrical design for illuminated signs. Illuminated signs shall be designed by an electrical engineer and shall be fabricated and wired to be compliant with current UL® listing requirements, and shall be UL® certifi ed.

2. All internally illuminated sign cabinets are to have an access panel that is tight fi tting, lightproof and waterproof. Access panels are to be in an accessible location, out of sight, and shall be shown on shop drawings.

3. Internally illuminated signs are to have adequate internal system of ventilation to assure a uniform dissipation of heat from electrical components of electrically powered and illuminated signs, heat (solar) absorption by sign and other sources. Any openings in exterior surfaces must be internally baffl ed to prevent light leaks and prevent entry of rain, snow, wind-blown debris, and other foreign matter, and are to be covered with interior color-coordinated insect screen.

4. Only labels required by law are permitted to be mounted on the exterior of the sign face, and they shall be located in a position that is as discreet as possible.

5. All internally illuminated interior metal surfaces shall be painted white using Matthews’ refl ective white paint, or shall be lined with 3M’s Matte White Light Enhancement Film, to enhance and evenly distribute light.

6. All electrical components shall be built to be housed within sign cabinets. All wiring and raceways within the sign are to be completely enclosed. Internal illumination by lamps is required to provide adequate and even illumination over the face of the sign without hot spots or shadows. “Halo” effects, “spreading” or similar light spill due to excessive transmission of the backlight source shall be minimized.

7. Illumination to be provided by exterior UL® rated LED only, (as specifi ed on design intent drawings). Lamps or other internal hardware must not be visible through the translucent letterforms and graphics.

8. All internally illuminated exterior signs are to have their own electric eye on/off control to turn the sign on at night and off in the morning, unless the Owner specifi es a need for a timer.

9. Verify location of power provided by others prior to sign fabrication.

10. Face-lit channel letters with a 16” or shorter cap height shall be trimless. Face-lit channel letters taller than 16” may use a low-profi le trim cap. Internally illuminated channel letters shall be illuminated using LED, unless otherwise noted on the design intent drawings. Transformers for channel letters shall be remote transformers wherever possible. If remote transformers are not applicable, then all electrical components shall be contained within the channel letter itself. Raceways are not acceptable unless specifi cally noted on the design intent drawing or if approved by the Owner. All raceways must be painted the same color as the wall on which the sign will be mounted. Channel letters to be painted on the inside with Matthews’ refl ective white paint, or lined with 3M’s Matte White Light Enhancement Film to enhance and evenly distribute light.

I. Fonts/TypefacesThe fonts used for this project were selected specifi cally for this project by the Owner, and include those listed in the graphic standards.

It is the responsibility of the fabricator to purchase the fonts.

No substitution of any other typefaces may be made. Under no circumstances are typefaces to be electronically distorted (“squeezed” or “extended”) for purposes of fi tting to the specifi ed sign or general alteration of the sign face composition unless noted in the drawings. This includes (but is not limited to) stretching, squeezing, tilting, outlining or shadowing.

1. All letterforms, symbols or graphics shall be reproduced either by photographic or computer-generated means. Hand-cut characters are not acceptable. Cutting shall be done in such manner that edges and corners of fi nished letterforms will be sharp and true. Letterforms with nicked, cut, ragged, rounded corners, and similar disfi gurements will not be acceptable.

2. All letterforms shall be made from material and gauge as indicated on design intent drawings. Typefaces shall be replicated as indicated on the drawing.

3. Ligatures are to be turned off.

4. Apostrophes are to be used, not foot marks. Note that there is a difference in most fonts.

5. Silk-screened and vinyl copy is to match the sheen of the copy panel background (satin). Edges of letters shall be straight and corners sharp. Surface of letters shall be uniform in color fi nish, and free from pinholes and other imperfections.

6. Silk-screened images shall be executed with photo screens prepared from original art. No hand-cut screens will be accepted. Original art shall be defi ned as artwork that is a fi rst generation reproduction of the specifi ed art.

19STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 20: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

Fabrication Specifications

7. Silk-screening shall be highest quality, with sharp lines and no sawtooths or uneven ink coverage. Screens shall be photographically produced. Application of inks through screens shall consist of one fl ood pass and one print pass. Images shall be uniform in color and ink thickness. Images shall be free from squeegee marks and lines resulting from improper print stroke or screen off contact height. Signs shall be placed in adequate drying racks with minimum of 2 inches between racks for ample airfl ow. Sign racks shall have system of forced airfl ow between layers to provide proper drying and curing of inks. After signs have dried completely according to the ink manufacturer’s time allowance, signs may be packaged.

8. “Pushed-through” copy must fi t accurately into routed portions of cabinet with tight, hairline joints and snugly into back of formed (channel) letters.

9. The edges and corners of routed letterforms shall be sharp and true. Letterforms with nicked, cut, ragged, rounded (positive or negative) corners, and similar disfi gurements will not be acceptable. Letterforms shall be aligned so as to maintain a base line parallel to the sign format, with margins and layout as indicated on design intent drawings and approved shop drawings. Vertical strokes shall be plumb. Mechanically fasten center of letters to acrylic plastic as described in the design intent.

10. Vinyl graphics and letterforms shall be computer-cut.

Installation

A. Permits and VariancesFabricator shall be knowledgeable of relevant local code requirements and honor same in fabrication and installation. Where applicable, it is the responsibility of the Fabricator to secure any and all necessary permits for signage installation. It is the responsibility of the Owner to secure variances, should any be required. It is the Owner’s responsibility to call the appropriate agency to have all underground utilities properly located and marked. Any damage to below-grade utilities or structures for which the Owner has provided adequate location information is the responsibility of the Fabricator.

B. Site VisitPrior to installation of the signs, the Fabricator is to visit the proposed site to observe existing conditions and verify all signage required and its location with Owner. At this time the locations shall be staked using a non-permanent visible device such as spray chalk or non-permanent paint. Certain signs may be located on sloped grades and may require uneven footings for each post. Site-verify all locations to determine special requirements for footing templates, if required.

The fi nal Sign Message Schedule and Sign Location Plan shall be consulted together and shall be approved by the Owner to determine the precise location for each sign. Any necessary adjustments will be made with the approval of the Owner.

C. Masonry/FootingsAny concrete bases for signage are to be poured in place and footings are to extend beneath the frost line, or deeper to meet local code. All footings or bases should be poured within a form and level with grade unless otherwise specifi ed in the design intent drawings. Foundation/footings should be level with grade unless

otherwise noted or as specifi ed by state or local code. Foundation/footings should not extend above grade more than 2” and exposed edges should be fi nished with a bevel to prevent chipping. It’s recommended that the concrete be fl oated by machine or hand before fi nishing in order to embed larger aggregates especially when part of the footing or base extends above ground. Concrete surface should have a smooth or brushed fi nish grade appearance. All concrete bases and footings should be edged to break any bond with the form and create a neat appearance. All forms should be removed once the concrete has properly cured. Concrete and reinforcement specifi cations shall be shown on shop drawing submittals. The Fabricator is responsible for the necessary templates, mounting plates and hardware for concrete and masonry bases. A minimum 2’ rock bed with landscape edging or concrete pad must be added around each concrete base as protection from landscaping maintenance as specifi ed on the drawings.

All masonry (concrete block, poured concrete, brick, slab, veneer, mortar, etc.) is to be properly treated and protected to maintain the structural integrity of the masonry work with exposure to all environmental conditions found at the site. For exposed or visible masonry, this shall include the application of protective sealers or similar fi nishes to diminish the effects of close-proximity sprinkling or irrigation systems.

Signs are to be mounted on J-bolt footings, centered on the concrete base or footing and engineered per code unless otherwise specifi ed in the design intent drawings.

D. Wind LoadSigns, banners and mounting devices shall be engineered to withstand a minimum 30-psf wind load normal to the sign, or greater as per local code, in addition to the weight of the sign. The Fabricator shall determine appropriate method of anchoring signs to the locations specifi ed to meet these requirements as well as all local code requirements.

E. MountingAll signs to be mounted level and true. All exposed hardware is to be touch-up painted on site as required. It is preferred that all bolts, nuts, washers, or other fasteners shall be stainless. However galvanized steel is acceptable, so long as all exposed surfaces are sealed.

While sign type drawings may specify or indicate possible mounting and/or mounting hardware details, the Fabricator will be able to substitute equal or better hardware and techniques, based upon their experience with similar mounting situations and as long as the visual appearance of the sign is not compromised from that shown in the design intent drawings.

All signage products must be installed such that there are no misalignments between visible components. Sign elements intended to be removable or changeable after installation must function as intended without binding, sticking or blocking. It will be the responsibility of the Fabricator to correct any installation misalignments at no charge.

Fabricator and their installers are expected to have knowledge of ADA and Title 24/OSHPD mounting guidelines and city zoning codes, general sign locating practices, and any particular unique installations

defi ned by Owner. It is the desire of the Owner that the Fabricator follow these guidelines as well as architectural cues in installing for the best visual placement, keeping a reasonable distance from protruding objects. Any signage that is improperly located is to be moved to the proper location by the Fabricator, and repairs to wall surfaces and signage are to be at the Fabricator’s expense.

If the installers are unable to make a decision about any sign locations, they can contact the Owner, providing a graphic representation of the questionable area, or contact the Owner for on-site options.

F. ElectricalThe Owner will be responsible for providing a power source to within 10 feet of the base of each sign requiring power (either at grade or below grade). Power is to be 120 or 277 (LED illumination should be 120) volts at 60 cycles unless otherwise noted in the documents. It is the responsibility of the Fabricator to manipulate the existing conduit to its proper location, install an external disconnect, extend the conduit through the concrete base (or posts) to align with the point of hookup, and run the power supply through it. Conduit running from the disconnect to the sign shall travel within the concrete base, not on its surface. The Owner will be responsible for the fi nal electrical connection.

G. PunchlistIt is required that the Fabricator complete a walk through with the Owner immediately following installation to identify any errors, such as construction or installation issues. Such errors are to be corrected in a timely manner, and to the satisfaction of the Owner.

H. Signage WarrantyThe Fabricator is to provide a written fi ve (5) year full replacement warranty to the Owner that all signs will be free of defects due to craft work and materials including, but not limited to:

• Bubbling, chalking, rusting or other disintegration of the sign panel, graphics or of the edges.

• Corrosion appearing beneath paint surfaces of panels, brackets, posts or other support assemblies (except as an obvious result of vandalism or other external damage).

• Corrosion of fasteners.• The assemblies not remaining true and plumb on their supports.• Fading, chalking and discoloration of the colors and fi nishes

within the vinyl and paint manufacturer’s stated warranty period.• Peeling, delamination or warping (“oil canning”).• Repair and reinstallation of signage due to failed mountings.

Fabricator shall also extend in writing to the Owner all manufacturers’ warranties.

I. Repair or ReplacementWithout additional cost to the Owner the Fabricator shall repair or replace, including installation, any defective signs or hardware which develop during the warranty period and repair any damage to other work due to such imperfections. The Fabricator will be required to fully replace all signs that are in error relative to the working documents (sign message schedule and sign type drawings) that will be submitted to the Fabricator upon award of contract.

20STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 21: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

CAUTION YELLOW

MATCHPANTONE 124

RED (P-4)PANTONE 200

GREEN (P-3)PANTONE 340

ORANGE (P-2) PANTONE 166

TEAL (P-5)PANTONE 632

GOLD (P-6)PANTONE 130

BLUE (P-7)PANTONE 660

PURPLE (P-1)PANTONE 2603

BROWN (P-8)PANTONE 4705

Aa Bb Cc Dd Ee Ff Gg Hh Ii Jj Kk Ll Mm Nn Oo Pp Qq Rr Ss Tt Uu Vv Ww Xx Yy Zz 1234567890Gotham Condensed Light

[P]

[DNE][NP]

[BF]

[i] [TRAM][NS]

[VALET]

ARROW

[TD] [DD] [SD]

[S] [RU]

Gotham Condensed Medium

Aa Bb Cc Dd Ee Ff Gg Hh Ii Jj Kk Ll Mm Nn Oo Pp Qq Rr Ss Tt Uu Vv Ww Xx Yy Zz 1234567890Myriad Pro Semibold Condensed (Canopy Identification Only)

Aa Bb Cc Dd Ee Ff Gg Hh Ii Jj Kk Ll Mm Nn Oo Pp Qq Rr Ss Tt Uu Vv Ww Xx Yy Zz 1234567890

OHSU BLUE

MATCHPANTONE 280

OHSU GREEN

MATCHPANTONE 369(3M Brilliant Green)

OHSU GOLD

MATCHPANTONE 123(3M Sunflower)

REDPANTONE 1797

WHITE

Symbols

Base Color

Typography

Color Palette

Parking Color Palette

Materials Palette

SILVER METALLICMESH SCREEN

01 02 13

OHSU LIGHT BLUEMATCH PANTONE 652(3M Evening Blue 3630-317)

23

06

PARKING BLUE3M Intense Blue(opaque)

22

03 04 05

20 24 2521 2726

09

07

SILVER METALLICMP18099 Platinum sparkle metallic

Opaque Vinyl:3M satin aluminum

Translucent Vinyl:3M Silver Scotchcal translucent

Translucent Vinyl:3M Day/Night FilmDark Gray

08

LIMESTONE (Faux)

10

BLACK

11

OHSU DARK GRAY

MATCH PANTONE 431(3M Slate Gray)

12

Fabricator is responsible for matching all colors and materials as specified and is required to provide color and material samples for approval. CONSISTENT AND ACCURATE COLOR REPRODUCTION IN THIS DOCUMENT CANNOT BE ASSURED DUE TO THE LIMITATIONS OF COLOR PRINTING TECHNOLOGY.

The Coated Pantone Matching System® and Matthews Paint system are used for specifying signage color matches. (In the absence of actual sign material color chip reference sets, actual specified product color swatches should be referenced for color matching.)

Shown here are approximations of the signage background colors and supporting accent colors. Actual color finishes on signage are to be matte or low luster (not shiny or glossy) and exclusively a premium acrylic polyurethane.

The font used for this project was selected specifically for this project by the Designer and Owner.

It is the responsibility of the fabricator to purchase the fonts. Purchasing information can be obtained at the following website: http://www.adobe.com/

No substitution of any other typefaces may be made. Under no circumstances are typefaces to be electronically distorted (“squeezed” or “extended”) for purposes of fitting to the specified sign or general alteration of the sign face composition unless noted in the drawings. This includes (but is not limited to) stretching, squeezing, tilting, outlining or shadowing.

All arrows, symbols or graphics shall be produced either by photographic or computer-generated means. Hand-cut characters are not acceptable.

No substitution of any symbols may be made. Under no circumstances are symbols to be electronically

distorted (“squeezed” or “extended”) for purposes of fitting to the specified sign or general alteration of the sign face composition unless noted in the drawings. This includes (but is not limited to) stretching, squeezing, tilting, outlining or shadowing.

Typesetting Example: Apostrophe

Visitor’s - correctVisitor's - incorrect

Typesetting Example: Ligatures

Staff - correctStaff - incorrect

P

P

BRB

A 10

21STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 22: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

Positive Logo Reverse Logo Recommended Clear Area for Signage

Positive Layout Reverse Layout Recommended Clear Area for Signage

Positive Layout Reverse Layout Recommended Clear Area for Signage

Logo Artwork

X

X

X

X X

OHSU Logos

Partnership Layouts

1/2 X

1/2 X 1/2 X

1/2 X

X

1/2 X

1/2 X 1/2 X

1/2 X

X

Partner Hospital

PartnerHospital

Partner Hospital

PartnerHospital

Partner Hospital

PartnerHospital

Ampersand (&) use is limited to:

Oregon Health & Science University

Center for Health & Healing

In all other cases, “and” is to be used, unless Marketing and Communications has provided approval.

22STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 23: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

Garage ECasey Eye

Rose Garden

Garage DCanyon

Crater Lake

Garage GDoernbecher

Dolly

Garage FCampus Drive

Falls

Garage KKohler Pavilion

Mt. Hood

Garage AEmma Jones

Bridge

Garage CSam JacksonLighthouse

Garage BPhysicians Pavilion

Coast

P2

Surface/P1

P4

P5

P3

P2

P1

P1

P2

P3

P4

P1

P2

P3

P4

P5

P6

P1

P2

P3

P4

P5

P6

P7

P1

P2

P3

P4

P5

P6

P7

P8

P9

P1

P2

P4

P3

P2

P1

GradePrimaryStreetEntry

23STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 24: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Cx-1 Campus ID,Pole Mounted

07Cut-out, pushed-through flush white translucent acrylic copy and logo text.

07

03

04

02Cut-out, pushed-through flush white acrylic with applied

translucent vinyl.

Marquam HillCampus

88°

Marquam HillCampus

THIS SIDE IS ALWAYSCLOSEST TO ROAD BACK VIEW

TOP VIEW

08 Fabricated aluminum panel constructed to support sign cabinet.

08 12" round post. Internal structure as required to support sign. All steel components painted with epoxy primer to prevent galvanic reaction between dissimilar metals.

08 1" deep raised bands.

08 14" diameter round base to cover all mounting hardware.

01

Tapered post cap08

1/4" thick aluminum bar08

SIDE VIEW FRONT VIEW

Concrete foundation cylinder

Galvanized or stainless steel "J" Anchor Bolts

Internal steel structureto be determined by the

sign fabricator.

Electrical connection to be coordinated by fabricator and owner representative.

DOUBLE-SIDEDINTERNALLY ILLUMINATEDFabricated aluminum cabinet. White LEDs to back light message panel logo and copy.

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

92°

88°

17'-1/2"

4"

6'-7 1/4"

3"

4'-11"

1 1/4"4 3/8"

1 1/4"1 5/8"

1 1/4"

4'-1"

2 3/4"

5'-4 3/8"1/2"

1'-0"

7'-0"

3"

4'-7 3/4"

1 1/4"

1'-10 1/2"

4 3/8"

5"

3"

1'-0"4 1/2"

4'-0"

3 5/8"

4 1/8"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

24STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 25: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Cx-2 Campus ID,Monument

88°

Marquam Hill Campus

Marquam Hill Campus

07

03

04

02

07Cut-out, pushed-through flush white translucent acrylic copy and logo text.

3" thick limestone cap with beveled edge.

Limestone veneer to clad Internal block wall with grout filled cells and reinforced horizontally.

Fabric wrapped flexible/perforated drain pipe sloped towards weep holes.

PVC drip pipe.

PVC drip pipe.

1'-0" deep planter bed

Cut-out, pushed-through flush white acrylic with applied

translucent vinyl.

THIS SIDE IS ALWAYSCLOSEST TO ROAD

BACK VIEW

TOP VIEW

08 Fabricated aluminum panel constructed to support sign cabinet.

08 12" round post. Internal structure as required to support sign. All steel components painted with epoxy primer to prevent galvanic reaction between dissimilar metals.

01

Tapered post cap08

1/4" thick aluminum bar08

SIDE VIEW FRONT VIEW

DOUBLE-SIDEDINTERNALLY ILLUMINATEDFabricated aluminum cabinet. White LEDs to back light message panel logo and copy.

Concrete foundation cylinder

Galvanized or stainless steel "J" Anchor Bolts

Concrete foundation

Internal steel structureto be determined by the

sign fabricator.

Electrical connection to be coordinated by fabricator and owner representative.

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

92°

88°

1'-0"4 1/2"

10'-6"

4 3/4"

7'-10 5/8"

2'-2 1/2"

2"

4"

7'-4 1/2"

10'-10 1/4"

9'-2 7/8"1/2"

1'-0"

3"

4'-11 7/8"

1 1/2"

2'-3 1/2"

5"

4'-0"

6 7/8"

9 3/4"

7"

1'-10 1/2"2'-1/2"

4'-6"

6"

6"

3"

2'-9" 2'-11 3/8" 5'-4 3/8"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

25STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 26: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Cx-2a Campus ID,Monument (48 sq ft)

Marquam Hill Campus

88°

07

03

04

02Cut-out, pushed-through flush white acrylic with appplied

translucent vinyl.

07Cut-out, pushed-through flush white translucent acrylic copy and logo text.

Marquam Hill Campus

3" thick limestone cap with beveled edge.

Limestone veneer to clad Internal block wall with grout filled cells and reinforced horizontally.

PVC drip pipe.

1'-0" deep planter bed

Fabric wrapped flexible/perforated drain pipe sloped towards weep holes.

PVC drip pipe.

FRONT VIEW

THIS SIDE IS ALWAYSCLOSEST TO ROAD

BACK VIEW

TOP VIEW

08 Fabricated aluminum panel constructed to support sign cabinet.

08 12" round post. Internal structure as required to support sign. All steel components painted with epoxy primer to prevent galvanic reaction between dissimilar metals.

01

Tapered post cap08

1/4" thick aluminum bar08

SIDE VIEW

DOUBLE-SIDEDINTERNALLY ILLUMINATEDFabricated aluminum cabinet. White LEDs to back light message panel logo and copy.

Concrete foundation cylinder

Galvanized or stainless steel "J" Anchor Bolts Concrete foundation

Electrical connection to be coordinated by fabricator and owner representative.

Internal steel structureto be determined by the

sign fabricator.

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

88°

92°

8'-6 1/2"

3 1/2"

6'-1"

2'-2 1/2"

2"

4"

5'- 7"

8'-1 3/4"

6'-11 1/4"1/2"

9"

2 1/4"

1'-10 1/2"2'-1/2"

4'-6"

6"

6"

3"

2'-1 1/4" 2'-2 3/4" 3'-10 3/8"

9"3 3/8"

3'-9"

1 3/8"

1'-8 1/2"

3 1/4"

3'-2"

3 3/8"

7 1/4"

5 1/2"

08.30.13 Design Intent10.21.13 Revised

26EXTERIOR DESIGN INTENT

Page 27: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent07.29.16 For Review

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Cx-3 Logo/Flame

stainless steelcounter sunk screw

.080" thick returns

Metal Panel. Architect toprovide details to awarded

fabricator.

1/8" thickback panel

White LED lights

High bond adhesiveto attach acrylic faceto letter return

1" spacer

Final wall connectionto be engineered

by awarded fabricator.

MountingHardwareStainless steel

counter sunk screw

Color low-profile trim cap

3/8" acrylicAluminum

angle support

Trimless Channel Letter Detail

FABRICATION:"Flame" portion of logo to be back-lit, white diffuser acrylic with surface applied (to face) Oracal® 8500 Translucent High Performance vinyl. OHSU Green to be 63 Lime Green, OHSU Gold to be 20 Golden Yellow, OHSU Blue to be 57 Pastel Blue. Bottom portion of logo to be day/night grey acrylic (product from ACRYLITE® or Let-R-Edge®). Painted aluminum returns to match silver metallic. Overall thickness not to exceed 5" and should be spaced off the wall 1".

LOGO ILLUMINATION:The entire logo to be full color during the day. At night, flame to glow full color and logotype to glow white. Interior of sign cabinet to be covered with 3M light enhancement film or with light enhancement white paint. Use white LED Lighting System for internal illumination. Number of modules and power supplies to be determined by fabricator. Complete lighting details to be provided by fabricator. Transformers to be located remotely within the building.

5"

1"

03

02

04

08

12

Building panel system.Details to be provided byarchitect to awarded fabricator.

8'-9"

5'-1"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

27STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 28: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent07.29.16 For Review

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Cx-3a Logo/Flame, Larger

5"

1"

FABRICATION:Day/night acrylic faces (product from ACRYLITE® or Let-R-Edge®). Painted aluminum returns to match silver metallic. Overall thickness not to exceed 5" and should be spaced off the wall 1".

LOGO ILLUMINATION:The entire logo to be black during the day. At night the flame and logotype should be white. Interior of sign cabinet to be covered with 3M light enhancement film or with light enhancement white paint. Use white LED Lighting System for internal illumination. Number of modules and power supplies to be determined by fabricator. Complete lighting details to be provided by fabricator. Transformers to be located remotely within the building.

11

11

11

08

11

6'-10"

11'-8"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

28STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 29: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Cx-4 Custom EntryOHSU Panel

TOP VIEW

08 Fabricated aluminum panel with break-formed return edges. Fabricator to field verify all wall conditions and determine final mounting hardware.

Full color, screen printed graphics

WALL MOUNTING BRACKETS AND/OR HARDWARE TO BE

ENGINEERED BY FABRICATOR

FRONT VIEW

4'-9 1/2"

4'-7 1/2"

equal equal

2"

3'-6"

6"

7 1/2"

2'-0 1/2"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

29STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 30: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Cx-5 Campus ID & Guide

South Waterfront

PParking

SIGN CABINET:Two-sided, internally illuminated aluminum sign cabinet, fabricated from 1/8" (th.) material. To be illuminated with LED lighting system. 1/8” thick aluminum sign face with cut-out/push-through white acrylic letters and graphics.

CHANGEABLE PANELS:1/8” thick aluminum panels with cut-out/push-through white acrylic letters and graphics.

TOP VIEW

SIDE VIEW(left profile)

SIDE VIEW(right profile)

SIGN BASE:1/8” thick aluminum fabricated base to have textured painted finish for a faux limestone appearance. Sign attachment, foundation and footing details to be engineered by fabricator.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

30STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 31: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

PParking PParking

SIGN CABINET:Two-sided, internally illuminated aluminum sign cabinet, fabricated from 1/8" (th.) material. To be illuminated with LED lighting system. 1/8” thick aluminum sign face with cut-out/push-through white acrylic letters and graphics.

CHANGEABLE PANELS:1/8” thick aluminum panels with cut-out/push-through white acrylic letters and graphics.

SIGN BASE:1/8” thick aluminum fabricated base to have textured painted finish for a faux limestone appearance. Sign attachment, foundation and footing details to be engineered by fabricator.

THIS SIDE TO FACE ROAD THIS SIDE TO FACE ROAD

Cx-5 CAMPUS ID & GUIDEScale: 1/2”=1’-0” on an 11” x 17” sheet

1'-4"1'-5"

8 1/2"

1'-1" 1'-1"

8 1/2"

6'-2"

4"2 1/2"

2"

2"

1"

1"

1"

10"

6'-0"

8'-6"

4'-7"

4"5'-5"

5 1/4"

2'-9"

2"2"2"

3'-3/4"

5'-7 3/4"

5'-8 1/8"

6"

6"

6 1/2"

5"

4"

6 5/8"

8"

2"2"2"

5'-7 3/4"

5'-8 1/8"

5'-5"

8"

6" 6 1/2"

5"

4"

6 5/8"

2"

1"

1"

1"

10"

4"

5 1/4"

2'-9"

6"

6'-2"

4" 2 1/2"

6'-0"

2"

6'-2 3/4"

6'-1 3/4"

1/2"1/2"

6'-1 3/4"6'-2 3/4"

6'-1 3/4"

1/2"1 3/4"

1'-11"

1/2"3 3/4"

1'-5"

1'-4"

1'-1"

8 1/2"

31STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 32: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent10.21.13 Revised01.24.14 Revised01.31.18 Revised

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Gx-0 Extra LargeGuide/ID, Double SidedGx-0a Single SidedGx-0NI Non-Illuminated

Doernbecher HospitalPermit Lots 10 20 30

A B C D

07

06

Individual aluminum message panels with cut-out, pushed-through flush white translucent acrylic

copy and parking symbol circles. Channels on top and bottom to fit internal sign cabinet rails.

Translucent white acrylic panel with translucent red vinyl background. Channels on top and bottom to fit internal sign cabinet rails.

01 Removeable side panels to secure message panels.

A

05 Translucent vinyl

11 Masked and sprayed graphics.

External Light fixture.Galen 3-inch LED Panel by SLV lighting

39.3"L x 1.26"H x 2.88"WBulb: 18 x LED/1W/120V

Aluminum construction - WhiteOR EQUIVALENT

Light to illuminate logo. Distance of fixture from sign face to be determined by fabricator.

Doernbecher HospitalParking A B C D

A B C D

OHSU Hospital

OHSU & DoernbecherEMERGENCY Physicians Pavilion

EMERGENCY

Physicians Pavilion

THIS SIDE IS ALWAYSCLOSEST TO ROAD

Sign posts length vary per location.Sign height at locations 001 & 051

to be 36" above grade084" square steel post. Wall thickness to be determined by fabricator. Post painted with

epoxy primer to prevent galvanic reaction between dissimilar metals.

Metal landscaping trim ring with

drain holes.

Recess filled to grade with grey colored gravel.

SIDE VIEW

Gx-0 BACK VIEW

Gx-0a BACK VIEW

TOP VIEW

08 Fabricated aluminum panel constructed to support sign cabinet.

Alternate emergency layout(Kern OHSU & Doernbecher letters to 25)

08 7" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to preventgalvanic reaction between dissimilar metals.

1/8" thick aluminum bar

01

Tapered post cap08

08

Counter-sunk screws painted to match cabinet

01

FRONT VIEW

Concrete foundation cylinder

Galvanized or stainless steel "J" Anchor Bolts

Electrical connection to be coordinated by fabricator and owner representative.

INSTALLATION NOTEWhere below ground footingsare not possible cover panels

are required to cover mounting hardware.

DOUBLE-SIDED(Single-sided cabinet has solid background panel)INTERNALLY ILLUMINATEDFabricated aluminum cabinet. White LEDs to back light message panel copy.

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

Gx-0NINON ILLUMINATED

Fabricated aluminum cabinet. Individual aluminum message panels with surface applied reflective vinyl graphics. No external light fixtures.

88°

2 1/2"

92°

88°

7 1/2"1 1/2"

6'-1/2"

5'-1/2"1/2"

7"4" 4'-6 1/2"

2 1/2"

10'-1/2"

2'-3"

4 3/8"

1'-5"

1 1/2"

7'-11 3/4"

1 1/2"

7 3/8"

3/8"

5"

eq

eq

4"

8 5/8"

1 1/2"5"

2"

7/8"1 1/8"5 3/8"1 1/4"

1'-2"

1"

2"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

32STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 33: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent10.21.13 Revised01.24.14 Revised

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Gx-1/Gx-1a Vehicular Guide,Large, Double Sided Gx-1a Single SidedGx-1NI Non-Illuminated

EMERGENCY

Kohler PavilionParking

07

06

Individual aluminum message panels with cut-out, pushed-through flush white translucent acrylic

copy and parking symbol circles. Channels on top and bottom to fit internal sign cabinet rails.

Translucent white acrylic panel with translucent red vinyl background. Channels on top and bottom to fit internal sign cabinet rails.

01 Removeable side panels to secure message panels.

A B C D

A B C DA

05 Translucent vinyl OHSU HospitalPhysicians Pavilion

SIDE VIEW

Gx-1 BACK VIEW Gx-1a BACK VIEW TOP VIEW

08 Fabricated aluminum panel constructed to support sign cabinet.

08 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to preventgalvanic reaction between dissimilar metals.

1/8" thick aluminum bar

01

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

THIS SIDE IS ALWAYSCLOSEST TO ROAD

Tapered post cap08

08

Counter-sunk screws painted to match cabinet

01

Metal landscaping trim ring with

drain holes.

Recess filled to grade with grey colored gravel.

Electrical connection to be coordinated by fabricator and owner representative.

DOUBLE-SIDED(Single-sided cabinet has solid background panel)INTERNALLY ILLUMINATEDFabricated aluminum cabinet. White LEDs to back light message panel copy.

Kohler PavilionParking A B C D

A B C D

FRONT VIEW

083" square steel post. Wall thickness to be determined by fabricator. Post painted with

epoxy primer to prevent galvanic reaction between dissimilar metals.

Concrete foundation cylinder

Galvanized or stainless steel "J" Anchor Bolts

OHSU HospitalEMERGENCY Physicians Pavilion

4'-11"

4'-1"3"

88°

6"1/2"

3"

1 1/2"

6"1 1/4"

6'-10 1/2"

1'-10"

6'-6"

3'-8"

7"

7"

1 1/4"4"

1 3/4"

6"1/4"4"

3 3/8"1 1/2"

5/8"1"4 3/8"

1"

2 1/8"

2"

92°

88°

Gx-1NINON ILLUMINATED

Fabricated aluminum cabinet. Individual aluminum message panels with surface

applied reflective vinyl graphics.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

33STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 34: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Gx-1b Vehicular Guide,Large, SJH Custom

01.31.18 Design Intent

OHSU Hospital Patient Drop-off

Multnomah PavilionParking Valet Drop-offPhysicians PavilionSam Jackson Hall

B

SIDE VIEW FRONT VIEW

TOP VIEW

OHSU Hospital

Multnomah PavilionParking Valet Drop-offPhysicians PavilionSam Jackson Hall

B

3'-11"

3 1/2"

3 1/2"

4 1/4"

2 7/8"

4"

4"1 5/8"

4"

1"2 7/8"

4 1/4"

2 7/8"

4"

2 7/8"

Fabricator to confirmwall radius

Approx 3" Approx 2"

The exposed portion of thetop and back of panel

is enclosed.

Fabricator to confirm sizeof return edges

Adjustable brackets BRACKET DETAIL

Concrete wallanchor

Painted 1/8” aluminum panel with break-formed return edges and surface applied reflective vinyl graphics.

PHOTO RENDERING OF SIGN LOCATION

Surface applied white reflective graphics.

07

Surface applied white reflective circle with translucent parking blue field with cut out letter.

0705

MOUNTING TO BEENGINEERED BY FABRICATOR

01

5'-10 1/2"

2 1/4"

2 1/4"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

34STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 35: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Gx-1cVehicular Guide,w/Custom LED

07

06

Individual aluminum message panels with cut-out, pushed-through flush white translucent acrylic

copy and parking symbol circles. Channels on top and bottom to fit internal sign cabinet rails.

Translucent white acrylic panel with translucent red vinyl background. Channels on top and bottom to fit internal sign cabinet rails.

01 Removeable side panels to secure message panels.

A B C DA

05 Translucent vinyl

Double-sided 19"H x 34"W x 10" deep (5" deep each) Daktronics AF-3200

8mm pixel amber LED displays. DatronicsAF-3200

OHSU HospitalEMERGENCY

Physicians Pavilion

SIDE VIEW

BACK VIEW TOP VIEW

08 Fabricated aluminum panel constructed to support sign cabinet.

08 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to preventgalvanic reaction between dissimilar metals.

01

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

THIS SIDE IS ALWAYSCLOSEST TO ROAD

Tapered post cap08

Counter-sunk screws painted to match cabinet

01

Metal landscaping trim ring with

drain holes.

Recess filled to grade with grey colored gravel.

Electrical connection to be coordinated by fabricator and owner representative.

DOUBLE-SIDED(Single-sided cabinet has solid background panel)INTERNALLY ILLUMINATEDFabricated aluminum cabinet. White LEDs to back light message panel copy.

A B C D

DatronicsAF-3200

FRONT VIEW

083" square steel post. Wall thickness to be determined by fabricator. Post painted with

epoxy primer to prevent galvanic reaction between dissimilar metals.

Concrete foundation cylinder

Galvanized or stainless steel "J" Anchor Bolts

OHSU HospitalEMERGENCY Physicians Pavilion

4'-11"

4'-1"3"

88°

6"1/2"

3"

1 1/2"

6"1 1/4"

6'-10 1/2"

1'-10"

6'-6"

3'-8"

7"1 1/4"

4"1 3/4"

6"1/4"4"

3 3/8"1 1/2"

2 1/8"

2"

92°

88°

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

35STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 36: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Gx-2 Vehicular Guide,Small, Double SidedGx-2a Single Sided

Kohler PavilionParking

07 Individual aluminum message panels with surface applied reflective graphics. Channels on top and

bottom to fit internal sign cabinet rails.

01 Removeable side panels to secure message panels.

A B C D

A

05 Translucent vinyl

EMERGENCY

A B C D

06

Kohler PavilionParking A B C D

EMERGENCY

A B C D

07

Individual alluminum message panel with surface applied reflective vinyl background to match red. Messaging to be surface applied reflective vinyl to match white. Channels on top and bottom to fit internal sign cabinet rails.

SIDE VIEW

Gx-2 BACK VIEW Gx-2a BACK VIEW

TOP VIEW

08 Fabricated aluminum panel constructed to support sign cabinet.

08 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to preventgalvanic reaction between dissimilar metals.

5/8" tall x 1/8" thick aluminum bar

01

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

THIS SIDE IS ALWAYSCLOSEST TO ROAD

Tapered post cap08

08

Counter-sunk screws painted to match cabinet

01

FRONT VIEW

083" square steel post. Wall thickness to be determined by fabricator. Post painted with

epoxy primer to prevent galvanic reaction between dissimilar metals.

Concrete foundation cylinder

Galvanized or stainless steel "J" Anchor Bolts

Metal landscaping trim ring with

drain holes.

Recess filled to grade with grey colored gravel.

DOUBLE-SIDED(Single-sided cabinet has solid background panel)

OHSU Hospital

OHSU Hospital

4'-11"

6"1 1/4"

3"

1 1/2"

5'-1 1/2"

1'-10"

4'-8 1/2"6"

1/4"4"

4'-1"3"

6"1/2"

3'-8"

2 1/8"

7"

7"

1 1/4"4"

1 3/4"

3 3/8"1 1/2"

5/8"1"4 3/8"

1"

2 1/2"

88°

92°

88°

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

36STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 37: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent12.10.13 Revision

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Gx-3 Post & Panel GuideDouble SidedGx-3a Single Sided

3 1/4"

TOP VIEW

Kohler Pavilion

EMERGENCY

A B C D

A

Parking Patient Self-Park

05 Translucent vinyl

EmergencyPatientParking

Kohler Pavilion

EMERGENCY

A B C D

07 Reflective vinyl graphics

Parking

K

Valet Drop-off

C

SIDE VIEW

CUSTOM LAYOUT

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

THIS SIDE IS ALWAYSCLOSEST TO ROAD

Gx-3 FRONT VIEW Gx-3b FRONT VIEW

Gx-3 BACK VIEW Gx-3a BACK VIEW

083" square aluminum post. Wall thickness to be

determined by fabricator.

Concrete foundation cylinder

CUSTOM LAYOUT

01 Fabricated aluminum cabinet with surface applied vinyl graphics.

08 3/16" thick aluminum plate

08Snap frame extrusion toallow message panel

to be changed.

REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue

with surface applied reflective vinyl graphics.

0705

88°

92°

3'-1"

2'-10"

2"

2'-10"

1"

3'-7"

2'-10"

2"

2"

3'-4"

1"

2'-11"

2'-9" 2"3 1/2"

1 5/8"

1 1/4"2 3/4"3/4"

4 3/4"1 3/8"3 1/4"1 1/2"4 3/4"1 3/8"5/8"1 1/4"

4 3/4" 3 1/4"

1/8" thickrule line

88°

88°

92°

3'-1"

2"

2'-10"

1"

2'-11"

2'-9" 2"3 1/2"

88°

3 5/8"

8 1/4"

2"4 1/8"

2"

06

07 Reflective vinyl graphics

Reflective vinylgraphics 1'-11"

11 7/8"

2 3/8"

5 1/2"

3"

5 1/2"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

37STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 38: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Gx-5 Pedestrian Guide,Double SidedGx-5a Single SidedGx-5b Wall Mounted

Client

Gx-5 TOP VIEW

Gx-5a TOP VIEW

Biomedical Information Communication CenterHatfield Research CenterMackenzie HallOHSU HospitalResearch Buildings

School of Nursing

Campus Services Building

Baird HallBiomedical InformationCommunication CenterRestrooms

Jones HallMackenzie Hall

Biomedical Information Communication CenterHatfield Research CenterMackenzie HallOHSU HospitalResearch Buildings

1 3/4"1 1/4" 7/8"

EMERGENCY

OSHU Hospital

Access is acrossthe street throughSam Jackson Hall

Between 9:00 p.m. and5:00 a.m. enter throughEmergency

Gx-5 SIDE VIEW Gx-5a SIDE VIEW Gx-5a BACK VIEW Gx-5 BACK VIEW

ALTERNATE LAYOUT 1 ALTERNATE LAYOUT 2

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

FRONT VIEW Gx-5b FRONT VIEW Gx-5b SIDE VIEW

Concrete foundation cylinder

PANEL ATTACHMENTPanels bonded to painted aluminum “U” channel posts. “U” channel posts attached to sign pole with machine screws.

2'-2 3/8" 2'-2 3/8"

Copy, arrows and symbols are surface applied opaque vinyl. Metallic silver rule is surface applied opaque silver vinyl.

1/8” thick painted aluminum panels. Post and backs of panels are painted silver metallic. Panels mounted to “U” channels. “U” channel and sign panel assembly mounts to pole with machine screws. Signs are single or double-sided.

08

08

06

05

01

2" square aluminum post

1'-7 1/2"

1'-6 1/2"1" 1"

1 1/4"

2'-0"

1"

5/8"1 3/8"

3/4" 1'-5"

1 3/4"1 1/4" 7/8"

3"

01

1'-7 1/2"

1'-6 1/2"1" 1"

1 1/4"

2'-0"

1"

5/8"1 3/8"

3/4" 1'-5"

3"

MOUNTING TO BEENGINEERED BY FABRICATOR

1 3/4"1 1/4"1 1/2"3/8"1 1/4"

4"3/8"

9 1/8"

3/8"

1 7/8"1 1/4"1 1/8"

1 1/2"1 1/4"7/8" 1"5/8"

3/4"1 7/8"1 1/8" 1"3/4"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

38STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 39: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Gx-5c/Gx-5dPedestrian Guide, SmallWall Mounted/Pole Strapped

DoernbecherChildren’s Hospital

OHSUHOSPITAL

Universal Channel Clamp

Standard stainless steel mountingbracket compatible with anySignfix support extrusion.

Bucklestrap

Stainless steel band. Use toattach Universal Channel Clamp

to round posts.

www.band-it-idex.com

WORLD HEADQUARTERS &WESTERN U.S. CUSTOMERSALES & SERVICE CENTERBAND-IT - IDEX, INC.A Unit of IDEX Corporation4799 Dahlia St.P.O. Box 16307Denver, Colorado 80216-0307Ph: 303-320-4555 FAX 303-333-6549

EASTERN U.S. CUSTOMERSALES & SERVICE CENTERBAND-IT - IDEX, INC.A Unit of IDEX Corporation3520 Progress DriveBensalem, Pennsylvania 19020Ph: 215-245-7290FAX 215-245-7291

Attachment Product available from:

Extrusion

Size, length, quantityand positioning to be

determined by Fabricator.

MOUNTING TO BEENGINEERED BY FABRICATOR

Gx-5c FRONT VIEW Gx-5c SIDE VIEW Gx-5d SIDE VIEW Gx-5d FRONT VIEW

Copy, arrows and symbols are surface applied opaque vinyl. Metallic silver rule is surface applied opaque silver vinyl.

Copy, arrows and symbols are surface applied opaque vinyl. Metallic silver rule is surface applied opaque silver vinyl.

1/8” thick painted aluminum panels.

1/8” thick painted aluminum panels.

Stainless steel straps

01

1'-0"

1'-6"

1"

1 1/4"1 1/4" 1"1" 3/4"

01

1'-0"

1'-6"

1"

5"

2"1"2"

1 1/8"2 5/8"

7'-0"

1"3"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

39STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 40: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Gx-5ePedestrian Guide,Custom Curve

EMERGENCY

Physicians Pavilion

Hatfield Research CenterOSHU HospitalTram

06

4"3/8"

4 1/8"3/8"

1 7/8"1 1/4"1 1/8"

1 1/2"

1 1/2"1 3/8"1 1/4"

1 1/4"

1 7/8"

FRONT VIEW

TOP VIEW

IMAGE OF SIGN LOCATION

SIDE VIEW

Copy, arrows and symbols are surface applied opaque vinyl. Metallic silver rule is surface applied opaque silver vinyl.

1/8” thick painted aluminum panels. Post and backs of panels are painted silver metallic. Panels mounted to “U” channels. “U” channel and sign panel assembly mounts to pole with machine screws. Signs are single or double-sided.

1'-6"

2'-0"

1 3/4"1 1/2"

01

MOUNTING TO BEENGINEERED BY FABRICATOR

CUSTOM CURVED PANEL REQUIRED.FABRICATOR TO FIELD VERIFY CURVE DIMENSIONS.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

40STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 41: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-1 Building ID,Pole Mounted, HC

HatfieldResearch

CenterBRB

Use Parking

5/8" tall x 1/8" thick aluminum bar

08

C

HatfieldResearch

Center

Use Parking C

SIDE VIEW FRONT VIEW

TOP VIEW

BACK VIEW

01

08

DOUBLE-SIDEDFabricated aluminum cabinet.

Fabricated aluminum panel constructed to support sign cabinet.

08 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to preventgalvanic reaction between dissimilar metals.

Painted band and return edges01

Painted band and return edges05

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATORConcrete foundation

cylinder

Galvanized or stainless steel "J" Anchor Bolts

Metal landscaping trim ring with drain holes.

Recess filled to grade with grey colored gravel.

Tapered post cap08

Surface applied reflective vinyl copy

07

07Screen printed graphics

07Surface applied white reflective vinyl background

4"1 1/4"

3'-7 1/4"

2'-9 1/2"2 1/2"

88°

92°

6"1/2"

88°

4'-6 1/2"

2'-6"

3 1/2"

8 1/8"

1 1/4"

2'-5 1/2"

10 5/8"

1 1/2"

6"

6 1/2"

4"2"4"

5/8"3 3/8"

4"

3 3/8"

6"1/4"

THIS SIDE IS ALWAYSCLOSEST TO ROAD

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

41STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 42: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-1aBuilding ID,Pole Mounted, RA

BRB

BRB

SIDE VIEW

BACK VIEW

FRONT VIEW

TOP VIEW

08

08

DOUBLE-SIDEDFabricated aluminum cabinet.

Fabricated aluminum panel constructed to support sign cabinet.

08 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to preventgalvanic reaction between dissimilar metals.

Painted band and return edges01

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATORConcrete foundation

cylinder

Galvanized or stainless steel "J" Anchor Bolts

Metal landscaping trim ring with drain holes.

Recess filled to grade with grey colored gravel.

Tapered post cap08

Surface applied reflective vinyl copy

07

11Screen printed graphics

07Surface applied white reflective vinyl background

Painted background 01

BiomedicalResearchBuilding

BiomedicalResearchBuilding

4"1 1/4"

3'-7 1/4"

2'-9 1/2"2 1/2"

88°

92°

6"1/2"

88°

4'-6 1/2"

2'-6"

3 1/2"

8 1/8"

1 1/4"

2'-5 1/2"

10 5/8"

1 1/2"

6 1/2"

4"2"4"

1 5/8"

7 1/2"

1 1/2"

1/2"1 3/8"3 3/4"THIS SIDE IS ALWAYS

CLOSEST TO ROAD

6"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

42STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 43: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

06.27.13 Design Intent10.21.13 Revised07.08.14 Revised01.31.18 Revised

Ix-1b Custom Building IDPole Mounted, HC

07Screen printed graphics

Elks Children’sEye Clinic

Casey Eye Institute

Parking E

5/8" tall x 1/8" thick aluminum bar

08

SIDE VIEW FRONT VIEW

TOP VIEW

08

08 Fabricated aluminum panel constructed to support sign cabinet.

Tapered post cap

08 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals.

086" wide x 4" deep fabricated aluminum support leg with 3" internal steel post. Post

painted with epoxy primer to prevent galvanic reaction between dissimilar metals.

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATORConcrete foundation

cylinder

Galvanized or stainless steel "J" Anchor Bolts

Metal landscaping trim ring with drain holes.

Recess filled to grade with grey colored gravel.

DOUBLE-SIDEDFabricated aluminum cabinet. White reflective graphics.

Fabricated aluminum cabinet.11

08

01

3'-9 1/2"

3'-2"2 1/2"

6"1/2"

3"

4"1 1/4"

6'-10 1/2"

2'-6"

4'-5 1/2"

1 1/2"

88°

92°

88°

THIS SIDE IS ALWAYSCLOSEST TO ROAD

9 1/4"

1 1/4"

2'-8 3/8"

10 3/4"

1"7"

6"

4"

5 1/2"

4"2"4"

2 3/4"4"

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

43STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 44: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent10.21.13 Revised07.08.14 Revised sign code01.31.18 Revised

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-1c Custom Building IDPole Mounted, HC

DatronicsAF-3200

Elks Children’sEye Clinic

Casey Eye Institute

Parking E

5/8" tall x 1/8" thick aluminum bar

08

SIDE VIEW FRONT VIEW

TOP VIEW

08

08 Fabricated aluminum panel constructed to support sign cabinet.

Tapered post cap

08 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals.

086" wide x 4" deep fabricated aluminum support leg with 3" internal steel post. Post

painted with epoxy primer to prevent galvanic reaction between dissimilar metals.

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

DATA SOURCE NOTEOwner to provide hardwire data

connection at sign location.

ALTERNATE DATA SOURCEWireless data connection moduleincorporated into sign cabinet.

Concrete foundation cylinder

Galvanized or stainless steel "J" Anchor Bolts

Metal landscaping trim ring with drain holes.

Recess filled to grade with grey colored gravel.

DOUBLE-SIDEDINTERNALLY ILLUMINATEDFabricated aluminum cabinet. White LEDs to back light white acrlylic cut-out push-through letters.

Double-sided 19"H x 34"W x 10" deep (5" deep each) Daktronics AF-3200

8mm pixel amber LED displays.

Fabricated aluminum cabinet.11

08

Electrical/data connection to be coordinated by fabricator and owner representative.

01

3'-9 1/2"

3'-2"2 1/2"

6"1/2"

3"

4"1 1/4"

6'-10 1/2"

2'-6"

4'-5 1/2"

1 1/4"

1'-11"

10"

88°

92°

88° 1 1/2"THIS SIDE IS ALWAYSCLOSEST TO ROAD

1 1/8"

2'-8 3/8"

10 3/4"

6"

4"

5 1/2"

4"2"4"

2 3/4"4"

07Screen printed graphics

9 1/4"

1 1/4"

1"7"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

44STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 45: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-2 Building IDWall Mounted, HC

70088°

TOP VIEW

SIDE VIEW FRONT VIEW

1"

2"

5/8" tall x 1/8" thick aluminum bar

08

08 Fabricated aluminum cabinet. Fabricator to field verify all wall conditions and determine final mounting hardware.

Painted band and return edgeswith surface applied reflective vinyl copy.

01

88°

92°Surface applied reflective vinyl copy

07

07Screen printed graphics

07 Surface applied white vinyl background

Painted background01

HatfieldResearch

Center

2'-4"

2'-1 1/4"

1 3/4"

3'-5"

3'-6"

2 1/2"

6 1/4"

1"

1"

1'-10"

8"

1"4 7/8"

3"1 1/2"

3"1 1/2"

3"

5/8"2 1/8"3"

2 1/4"

WALL MOUNTING BRACKETS AND/OR HARDWARE TO BE

ENGINEERED BY FABRICATOR

4 1/2"11/16"

1"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

45STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 46: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-2aBuilding IDWall Mounted, RA

BiomedicalResearchBuilding

BRB

TOP VIEW

SIDE VIEW FRONT VIEW

1"

2"

08 Fabricated aluminum cabinet. Fabricator to field verify all wall conditions and determine final mounting hardware.

Painted band and return edgeswith surface applied reflective vinyl copy.

01

88°

92°

88°

Surface applied reflective vinyl copy

07

07

07 Surface applied white vinyl background

Painted background01

11Screen printed graphics

6 3/16" 4 1/2"11/16"

1"

2'-4"

2'-1 1/4"

1 3/4"

3'-5"

3'-6"

2 1/2"

6 1/4"

1"

1"

1'-10"

8"

1"4 7/8"

3"1 1/2"

3"1 1/2"

3"

1 1/8"

5 3/4"

1 1/4"

1/4"2 3/4"

WALL MOUNTING BRACKETS AND/OR HARDWARE TO BE

ENGINEERED BY FABRICATOR

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

46STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 47: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-4Entrance IDWall Mounted

Hours of Operation:

MultnomahPavilion

Smoking is prohibited on this campus

Hours of Operation:

Emma Jones Hall

Smoking is prohibited on this campus

Hours of Operation:

BiomedicalResearch Building

Smoking is prohibited on this campus

BRB

07Screen printed graphics

4 1/2"

FRONT VIEW

TYPICAL LAYOUT ALTERNATE LAYOUT

SIDE VIEW

Copy and logo are surface applied opaque vinyl. Metallic silver rule is surface applied opaque silver vinyl.

1/8” thick painted aluminum panels.

01

MOUNTING TO BEENGINEERED BY FABRICATOR

1'-10"

1'-8 1/2"1 1/4" 1 1/4"

3 "

2'-5 1/2"

1 3/8"

2'-3"

1 1/8"

4 1/2"

7/8"1/4"2 1/2"

1 3/4"1 1/4"1 3/4"

2 3/4"1/4" 1/2"1"

6 3/8"

3/4"

4 1/2"

7/8"eq

eq

1/4"

1 3/4"1 1/4"1 3/4"1 1/4"1 3/4"

1/4" 1/2"1"

6 3/8"

3/4"

2"

2'-8 1/4" 2'-8 1/4"

Accessible Entrance

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

47STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 48: STANDARDS MANUAL FOR WAYFINDING SIGNAGE · STANDARDS MANUAL FOR WAYFINDING SIGNAGE August, 2018 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 corbindesi gn P e o ple

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-5Emergency ID

1'-2"1'-2"

EMERG

ENCY

EMERG

ENCY

EMERG

ENCY

07Cut-out, pushed-through flush white translucent

acrylic graphics.Font: Gotham XNarrow Bold

07Surface applied reflective vinyl graphics VALET

PARKING

VALETPARKING

VALETPARKING

LEFT SIDE VIEW

RIGHT SIDE VIEW BACK VIEW(building side) REPLACE EXISTING SIGN

TOP VIEW

REUSE EXITING FOUNDATION.MOUNTING TO BE

ENGINEERED BY FABRICATOR

Existing foundation

Electrical connection to be coordinated by fabricator and owner representative. Existingsign is illuminated.

06FOUR-SIDED INTERNALLY ILLUMINATEDFabricated aluminum cabinet. White

LEDs to back light message panel copy.Font: Gotham XNarrow Bold

FRONT VIEW(street side)

12'-0"

1'-3"

6'-4"

2 1/2"1 1/4"

2 1/2"

1'-2" 1'-2"

eq 8 1/4" eq

4 5/8"

6 1/4"

eq 8 1/4" eq

5 1/2"

1 7/8"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

48STANDARDS MANUAL FOR WAYFINDING SIGNAGE